////// SUBSTATIONS SCMS. Stray Current Monitoring System

Similar documents
////// SUBSTATIONS. Voltage Limiting Device. VGuard

DC Substations / Supply Program

////// SUBSTATIONS. Control command and local Scada

Traction Power Systems / Program

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)

Specification Voltage Limiting Device

////// SUBSTATIONS SEPCOS. Control and protection relay

High-Speed DC Circuit-Breakers rolling stock Type UR26, UR36 & UR40

RAIL PRODUCTS CATALOG. T.EL.FER. srl

tapcon 230 user-friendly, FleXiBle and reliable. transformer control

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

DIRIS A & DIRIS B Power Metering and Monitoring Devices

Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power Transformers

Equipment Strategy For High Voltage Circuit Breakers

INVERTER COMMISSIONING CHECKLIST

G - Base. Relays THREE PHASE + NEUTRAL CURRENT PROTECTION RELAY

MiCOM P111. Three phase and earth fault overcurrent relays

mark150s mark150/485s DDC controllers Summary

TAPCON NEXT-GENERATION VOLTAGE REGULATORS. transformer control

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

DRAFT. Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters. 1.0 Introduction DANGER. 1.1 Related Documents

MESP TECHNICAL SPECIFICATION FOR SCADA CABLING IN SUBSTATIONS

Medium-Voltage Drive SINAMICS SM150. Type 6SL3845. Tests carried out on drives This documentation pertains to SM150 wassergekühlt G20 F03 F72 F79 F76

ETSI EN V1.2.1 ( )

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

For Transmission, Distribution and Machinery protection.

TRACTION SUBSTATIONS CITY ELECTRIC TRANSPORT RAILWAYS METRO BUILDING FUTURE TOGETHER!

Integral solution for photovoltaic plants supervision

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Features. Applications and Benefits TRC ELECTRONICS, INC

ELPROMA NTSprotect Surge Protection

A NEW DATA LOGGER Stand alone. Secure. Fast.

PSI-MODEM-SHDSL/SERIAL

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

MV Network Managment Fault tracking, monitoring and control. Easergy Range Merlin Gerin

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Feeder protection relay SPAA 121 C. Product Guide

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide

Automation System Solutions

Performance. Simplicity. Sepam, over 20 years of experience of the world leader. Sepam protection relays. For your peace of mind

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, N 2 O, CO 2 & H 2 O

Using the Bitronics 70 Series to Improve Local Monitoring and Control

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Bus Bar Protection Relay B-PRO 4000

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

An all-in-one module. Archiving Up to 50,000 data items time-and-date stamped and saved to flash memory

PERMANENT DOCUMENT. Annex AU to Routine Test Requirements for manufacturers (as per Article 9 of the Agreement)

AUTARKIC PROCESS MANAGEMENT

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values

Earth-fault Relay SPAJ 110 C. Product Guide

TFS 2100 Traveling Wave Fault Location System

Designing a new IEC substation architecture

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Technical Hotline: (800)

SOFREL LT/LT-US Data loggers Wastewater network solutions

Heating Circuit Controller

FAQ about Drives Technology

ENERGY AND POWER SYSTEM PLANNING DEPARTMENT

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

Airfield Lighting Control System

OHL Fault Indicators Grid Monitoring Software

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

MV NETWORK AUTOMATION IN THE TOWN OF MILLION - ZAGREB (CROATIA)

MV NETWORK AUTOMATION IN THE TOWN OF MILLION - ZAGREB (CROATIA)

PSSS/PSAC Engineering, Muhammad Adil, Substation Automation Systems. ABB Group October 29, 2014 Slide 1

Best Practice in Industrial Data Communications. Turkey, Istanbul, Wyndham Grand Istanbul Levent. Training Course : Training Course For One Week In

CONNEX. The Plug-in Connection System for Power Transformers and Gas-Insulated Switchgear. the power connection THE PFISTERER GROUP

Power Systems Communications Implementation of IEC61850 in a Substation Environment

Substation Automation Products. Line differential protection RED670 Relion 670 series

JUMO mtron T. Measuring, Control, and Automation System. Features. Brief description. Systembus LAN. Data Sheet Page 1/12. Com1.

Products Portfolio. Pole mounted Vacuum Recloser

Switching modules for AC 230 V, non-potential-free, single and double module

SIMOCODE 3UF Motor Management and Control Devices

SM100. On-Line Switchgear Condition Monitoring

COUNTIS E. Active and reactive energy meters and multi-utility pulse concentrators

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

Perfect protection smallest space

p. 1 p. 9 p. 26 p. 56 p. 62 p. 68

UPLC-100. Universal Power Line Carrier. 5C Communications Inc.

Title System Substation Commissioning Tests. Reference Number PCP 07 - (RIC Standard: EP SP)

Gelo LED Driver 100W, Single output RGLD100-24

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

GRYF. Measuring Instruments. measuring electrochemical and physical values. monitoring the environment. controlling technological processes

Non-conventional instrument transformers Advanced GIS substations with IEC LE process bus

IMIO100 IMIO105. DDC controllers. Summary

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

SWT 3000 Teleprotection siemens.com

InteliPro. Protection Relay for Parallel Applications. Technical Specification

NTS-protect. Description of GPS antenna and NTS time server connection via system lightning protector system /NTS-3000, NTS-4000, NTS-5000/

ENhanced TEChnology. Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver.

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

eps Network Services ASP Certificate

An expert solution is within your reach. EORSys. We take care of it.

Remote Terminal Unit ER1000 APPLICATION FEATURES

SPM Series. Plug-in Surge Protection

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM

Transcription:

////// SUBSTATIONS SCMS Stray Current Monitoring System

GENERAL INFORMATION The operation of DC traction systems requires suitable measures to prevent corrosion caused by stray currents on railway and non-railway installations. In this scope, the European standard EN-50122-2:2011 (Annex B) recommends a continuous supervision of the rail insulation. Sécheron Stray Current Monitoring System (SCMS) is a straightforward and efficient method of stray current monitoring avoiding manual repetitive measurement and any interference with the stray current collecting system. The system measures continuously the rail-to-earth potential under operational conditions, complete with central analysis, visualization, signaling and archiving capacities. The stray currents are defined as the currents that has deviated from their intended paths. Any metallic structure buried in soil, for example a pipe line, represents a low resistance current path and is therefore fundamentally vulnerable to the effects of stray currents. 1 ampere of stray current can oxidize 9.11 kilograms of iron per year. + - Return current Corrosion underground pipes Corrosion Stray current MAIN BENEFITS MAIN BENEFITS D Set up of network lines and stations, up to 10 lines and 100 control points. D Data acquisition and transmission through the communication network. Determination on data reference. Integration of specific algorithm depending on the type of network. Permanent automatic analysis of recorded values and manual analysis possible. Alarm and localization of the detected fault. Export and backup of measured and recorded values. Communication with Scada system. 2 SCMS / Stray Current Monitoring System

PRINCIPLE OF SCMS IN FLOATING CASE As the return is floating, the potential between earth and rails fluctuates. + Substation - Electric circuit Traction current in the wire of contact Current on the rail +U Distribution of the potential Potential of the rail compared to the neutral without insulation deficiency Neutral ground Potential of the rail compared to the neutral with insulation deficiency -U -2U A healthy system presents a specific voltage profile called reference or imprint. A deficiency of insulation between the rail and the earth will modify this voltage distribution. The track potential can be used to ensure the healthy of the insulation and determine a modification in behavior of the stray current by comparison with the reference curves. The SCMS is based on a rail potential measure. /// ADVANTAGES Measure more simple and practical. No interference with Stray Current Collecting System. Best arrangement to monitor level of stray current. /// DISADVANTAGES Relative and indirect measure. Dependent of the line operation (trains, headway, traction substation out of service). The line must be certified healthy and compliant with the requirements of the standard before the reference recording. The SCMS can adapt to either an existing or a new network. SCMS / Stray Current Monitoring System 3

ARCHITECTURE Central Evaluation Unit Remote Evaluation via Modem or Internet + - Contact line Return circuit Measuring System V V V V Structure Earth Data Transmission DATA COLLECTION /// DATA COLLECTION FROM VGuard (VOLTAGE LIMITING DEVICE) Already compatible with SCMS, the VGuard collects measurement along the line and transmits data via possible communication protocol. Voltage between the return circuit and the earth structure through a high accuracy sensor. Potential current flowing in the VGuard through a high accuracy sensor. VGuard status. STRAY CURRENT MONITORING SYSTEM BUS PLC PLC PLC A A A V V V VGuard VGuard VGuard /// DATA COLLECTION WITHOUT VGuard The accuracy of the system can be increased by installing additional measuring devices along the line. Integration can be done either by Sécheron or by the customer himself. 4 SCMS / Stray Current Monitoring System

DATA ANALYSIS /// CENTRAL EVALUATION UNIT (CEU) Functions of SCMS are performed at the CEU. The CEU includes an interface program to plot the real-time data being captured by the SCMS, as well as the data stored in the database. It realizes permanent automatic analysis of recorded values and an alarm is displayed in case stray current increases. This interface program also allows the user to visualize the data in different ways, export the plotted data, perform various manual analysis of stored data and parameter the SCMS. The CEU is designed with enough memory to keep at least 16 weeks of instantaneous values and archiving average values for 10 years. Stored data at the CEU is safely kept in a redundant RAID-1 hard drive system. The data can be exported to text files. The CEU communicates with the network and Scada system through different types of communication protocols: IEC 61850, IEC 60870-5-104 (-5-101), Modbus-TCP, DNP 3.0 with flexible connectivity (copper cable or optical fiber). EXAMPLES OF INTERFACE SCREENS Overview of the line Instantaneous view Time view Short-term and long-term values are displayed. The short-term values allow the analysis of insulation deficiency. The long-term values allow the analysis of tendency. Stations view Typical values of the line potential during operation are displayed (digital imprint). This screen also allows to reference the localization of the insulation deficiency. At the end of each day, the software generates automatically an analysis file of data recorded during the day and saves it as CSV file. The analysis window allows to access the history files and to generate a PDF report. SCMS / Stray Current Monitoring System 5

ALARM AND EVENT MANAGEMENT MEASURE Maximum number of lines 10 Maximum number of measuring points 100 for one system Frequency of acquisition 1 sec COMMUNICATION Communication protocols IEC 61850, IEC 60870-5-104 (-5-101), Modbus-TCP VISUALIZATION AND ARCHIVING Instantaneous values Short analysis values Long analysis values Total memory size Available languages In function of time Last 16 weeks Average values / Average of the absolute value In function of time or position Average window from 1 to 60 min Archiving for 10 years min Average values / Average of the absolute value In function of time or position Average window from 1 to 30 days Archiving for 10 years min 1 TB Multi-languages ANALYSIS Number of acquisitions for the reference profile Number of acquisitions (global) Daily recording period 10 most relevant measurements All points for 16 weeks Mean values saved for 10 years Adjustable HISTOGRAM OF THE OPERATION NUMBER OF THE CONTACTOR Live alarms list Reports 6 SCMS / Stray Current Monitoring System

MEASUREMENT AND CERTIFICATION Before the recording of the reference data, Sécheron can provide the service of its earthing and bonding experts for the certification of the track. This expertise allows to check if the installation meets the characteristics defined in the European standard EN 50122-2:2010: Rail resistance measure. Conductance per length between running rails Project start and structures. Insulating rail joints certification. Stray current interference of reinforced concrete structures. Assistance with reference data recording. Stray current emission. Expertise and recommendation. Training of personal. Parameterization support. Design & Construction phase Commissioning phase Earthing and bonding engineering service Training to control the conductance between earth and rails before welding Certificate of Rail Insulation Joint Certificate of structure potential change less than 200 mv Certificate of trackwork (rail insulation) Simulation of rail earth potential The variation of the structure potential can be considered as null and so compliant with the requirement of EN 50122-2 standard (< 200 mv). v= com Operation phase Time Reference recording phase Definition of protection settings Monitoring for maintenance (test interval) REFERENCES Sécheron has experience in delivering stray current monitoring systems for subway, tramway or light rail systems. For each project, Sécheron provides maintenance and improvement of the system. The quality of software and parameter settings have been improved continuously based on field experience and permanent return of experience thanks to close cooperation with operators. SUBWAY Commissioning: 2012 / LIGHT RAIL Commissioning: 2014 / Bangalore (India) Gold Coast (Australia) SUBWAY Commissioning: 2016 / SUBWAY Commissioning: 2016 / Kuala Lumpur (Malaysia) Bangkok (Thailand) SUBWAY Commissioning: 2017 / LIGHT RAIL Commissioning: 2017 / Kochi (India) Sydney (Australia) SCMS / Stray Current Monitoring System 7

SG825868BEN_C01-09.17 Sécheron SA Rue du Pré-Bouvier 25 1242 Satigny - Geneva CH-Switzerland www.secheron.com Tel: +41 (0)22 739 41 11 Fax: +41 (0)22 739 48 11 substations@secheron.com This document is not contractual and contains information corresponding to the level of technology at the date of printing. Sécheron reserves the right to modify and/or improve the product, whose characteristics are described in these documents, as required by new technology at any time. It is the purchaser s responsibility to inform himself, no matter what the circumstances, of the product s maintenance conditions and requirements. Sécheron reserves all rights, especially those arising from our General Delivery Conditions. Copyright 2017 Sécheron SA