DC Substations / Supply Program

Similar documents
Traction Power Systems / Program

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)

////// SUBSTATIONS. Voltage Limiting Device. VGuard

////// SUBSTATIONS. Control command and local Scada

////// SUBSTATIONS SCMS. Stray Current Monitoring System

////// SUBSTATIONS SEPCOS. Control and protection relay

Specification Voltage Limiting Device

EFASOLAR PVStation Solutions

Benefits, offering and references

Our Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium

High-Speed DC Circuit-Breakers rolling stock Type UR26, UR36 & UR40

Grid Automation packaged solutions Optimal automation of medium voltage grids

Est Constant Current Regulator MC4 3kW 30kW

For Transmission, Distribution and Machinery protection.

POWER GRIDS. We are bridging the gap. Enabling Digital Substations.

IDS SAS. Station Automation System for Complex Applications

Presented by: Oscar Araujo Photovoltaic Solutions Manager. 4 th Canadian German Solar PV Conference March 2 nd 2011

iswitch imotor Compact QR

ISIO 200. Binary Input/Output (I/O) terminal with IEC interface

High Safety low voltage switchgears For maximum requirements far beyond all standards.

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

UniGear type ZS1. SSC (Switchgear System Connectivity)

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

MINER-S Station Controller

PRODUCT FEATURES AND ADVANTAGES

Feeder/ Motor Protection Relay VAMP 40

MESP MODULAR SUBSTATION USER REQUIREMENTS

PROTECTION RELAYS: INNOVATIONS FOR THE BENEFIT OF THE USER

Scout-S Station Controller

Alberto Carini, LPLS Italy, June 2013 MNS is The Intelligent MCC. ABB Group June 21, 2013 Slide 1

VIP 40/45 VIP 400/410

MNS Platform, low voltage systems Rear Access Power Motor Control Center. Alberto Carini, Global Product Manager

Title System Substation Commissioning Tests. Reference Number PCP 07 - (RIC Standard: EP SP)

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

Power supplies.

UniSec, MV AIS for Secondary Distribution Smart Grid applications

This image cannot currently be displayed. Sarel Pelser. ABB Group May 27, 2014 Slide 1

Est Static Transfer Switches STSt A STSi A

Package Substation. The efficient solution for your electrical distribution network

What fulfills the highest demands on the current and voltage quality?

Air-insulated medium-voltage secondary distribution switchgear

Products Portfolio. Pole mounted Vacuum Recloser

PREFABRICATED SUBSTATIONS AND E-HOUSES. tgood.com. Energy, Fast!

Synchro-check relay. Application

Automation System Solutions

aentron Energy System 1 to 900 Vdc

SCADA Training - T&D Automation

Est Constant Current Regulator MC2 3kW 30kW

Solution Railway. tgood.com

Battery charger. Power plants. Substations. Rail and infrastructure. Industry. Thyristor controlled with controller GMU

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

Energy Storage Systems Utilizing the SunDial Plus 30PV+S Inverter

Make the sun your energy source. SOLAR

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

p. 1 p. 9 p. 26 p. 56 p. 62 p. 68

MEGADRIVE-LCI. Medium voltage AC drive for control and soft starting of large synchronous motors

Company main topic [ Product ] TracFeed DCP2. English. Multifunctional Device for Control and Protection in DC switchgear.

SM100. On-Line Switchgear Condition Monitoring

Quasar Series Technical Features

SICAM RTUs Ready for the Future

Grid Automation Controller COM600 How it fits into the Smart Grid?

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

SIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations

PSSS/PSAC Engineering, Muhammad Adil, Substation Automation Systems. ABB Group October 29, 2014 Slide 1

Substation SCADA Monitoring

ATV650U30N4E variable speed drive ATV650-3kW V - IP55 - disconnect switch

SICAM A8000 Series. Operation, telecontrol, and automation in the smallest spaces. siemens.com/sicam-a8000

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip

PRODUCTS AND SERVICES. At a glance

power pazifik MV Switchgear Secondary Distribution Networks Fully Gas-Insulated Modular and Compact (RMU) System Up to 36 kv

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

CONTENTS... 2 COMTROLL SAS. SURVEILLANCE AND AUTOMATION SYSTEM...

UNITROL 5000 Excitation Systems for Medium and Large Synchronous Machines

ELG4125: System Protection

Equipment Strategy For High Voltage Circuit Breakers

POWER GRID AUTOMATION. Pág.. n. RMU Automation

MV Network Switchgear, Protection and Control

Siprotec 7ST61 / 7ST63

Innovation on Medium Voltage Switchgear

L S T LLOYD SYSTEMTECHNIK IREG. The Latest Generation of Digital Voltage Regulators. Concept. Firmware

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads

ELSETA IOMOD 8DI8DO. User manual. Elseta 3/2017 V1.0

Performance. Simplicity. Sepam, over 20 years of experience of the world leader. Sepam protection relays. For your peace of mind

Residual overvoltage relay

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power Transformers

Earth-fault Relay SPAJ 110 C. Product Guide

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM

MV NETWORK AUTOMATION IN THE TOWN OF MILLION - ZAGREB (CROATIA)

MV NETWORK AUTOMATION IN THE TOWN OF MILLION - ZAGREB (CROATIA)

Electrical Integration with Smart Communication

Voltage Transducer UMT516 / MT516

POWER ELECTRONICS / SD700 SERIES SD700 VARIABLE SPEED DRIVES

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

CABLETROLL 3 CABLETROLL CABLETROLL CABLETROLL CABLETROLL LED-2 5 CABLETROLL CABLETROLL REMOTE INDICATION 7

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

Binary output and supervision 520CSD01 Data sheet

Air Cooled Medium Voltage AC Drives ALSPA VDM6000

Transcription:

DC Substations / Supply Program

Sécheron offers an extensive range of products for DC electrification of public transport This document is intended to give a brief idea of our services, cubicles and systems in the field of DC traction substations. Detailed brochures are available for all components. ENGINEERING SERVICES /// COMPUTER AIDED SIMULATIONS AND CALCULATIONS Dynamic simulation of power consumption and complete network analysis, taking into consideration all characteristics of the vehicles and the network. Substation positioning and total energy consumption including energy storage and/or inverter solutions. Conformity study with applicable standards. /// DESIGN AND CONSULTANCY SERVICES Harmonic filter design for DC networks. Concepts of protection (overhead lines, earthing, bounding, selectivity, etc.). Consultancy service to define technical specifications including transformers and medium voltage switchgear design. /// PROJECT MANAGEMENT IPMA (1) Certified project managers /// RAMS (2) STUDIES /// OTHER SERVICES Supervision of installation. Commissioning. After-sales service. Maintenance. (1) IPMA = International Project Management Association (2) RAMS = Reliability, Availability, Maintainability and Safety 2 DC Substations / Supply Program

DC SWITCHGEAR /// DESIGN The cubicles can be combined in various ways to complete substations, offering the systems engineer the greatest possible implementation flexibility. According to their design, they can be used as feeders, bus tie cubicles and for other applications. /// HSCB CUBICLE RANGE Full conformity and type tested according to EN 50123, IEC 61992 and IEEE Std C37.14 and C37.20.1. Integration of protection and control relays made by Sécheron (SEPCOS). Various configurations available: Rectifier Breaker, Feeder Breaker, By-Pass, Breaker... Possibility to integrate disconnecting or change-over switches. HIGH-SPEED CIRCUIT BREAKER CUBICLE (TYPE MBS) Type Rated operational voltage Rated output current Rated current busbar MBS 500 900 / 1800 V Up to 6000 A Up to 11000 A MBS 800 900 V 8000 A Up to 11000 A MBS 800 3600 V 4000 A Up to 11000 A /// DESIGN Compartmented metal enclosed cubicles with high speed circuit breaker mounted on a withdrawable trolley. Suitable for feeding applications for heavy DC railways networks. DISCONNECT SWITCH CUBICLE Type Rated operational voltage Rated output current Rated current busbar MBS-D05/x MBS-D08/x MBS-D12/x MBS-D16/x 900 / 1800 V 2000 to 8000 A Up to 11000 A 3600 V 2000 to 6000 A Up to 11000 A /// DESIGN Compartmented metal enclosed cubicles with one or more disconnecting switches. Suitable for all feeding applications for DC railway networks. Possibility to integrate a variety of protection: Frame leakage protection (64), Negative-earth protection (59), Return current detection (32). CIRCUIT BREAKER CUBICLE (TYPE SECUB-2) Type Rated operational voltage Rated output current Rated current busbar SECUB-2 UR15 900 V 1500 A 4000 A SECUB-2 UR26 900 V 2600 A 4000 A /// DESIGN Compartmented metal enclosed cubicles with high-speed circuit-breaker mounted on a withdrawable drawer. Delivered with trolley for maintenance purposes. Especially suited to all feeding applications for LRT, LRV and trolleybuses. DC Substations / Supply Program 3

TRANSFORMERS Based on a strong experience, Sécheron provides an engineering and consulting support service for the transformers, including specification, monitoring during the manufacturing process and assistance. Sécheron is also able to calculate the main characteristics of traction transformers. They are adapted to the client network configuration, being 1 or 2 secondary windings, cast-resin or oil-immersed transformers, self cooled or forced air, with a 6, 12 or 24 pulses system. The transformer core and windings are manufactured in accordance with the best modern practice to withstand the stresses of heavy traction cyclic loading and track faults. To ensure a good harmonization, Sécheron is able to provide the complete transformer-rectifier group. RECTIFIERS Type / Design Power Rated voltage Fixed mounting 900 to 6000 kw 500 to 3000 VDC Withdrawable type 900 to 5000 kw 500 to 3000 VDC Special design Up to 10 MW More than 3000 VDC Variety of connections (3 phase bridge, 2 x 3 phase bridge, 6 / 12 / 24 pulses output). Protection (RC over voltage protection, Snubbers, Diode fuses, Over current protection). Cooling: Natural air. Mounting: Fixed or withdrawable. Possibility to integrate Inter-Phase coils. INVERTERS Type Rated power Rated voltage IGBT Inverter 500 to 3000 kw 750 to 2000 VDC Thyristor Inverter 500 to 4000 kw 750 to 3900 VDC Cost savings through recovery of the excess braking electrical energy. Reduction of heat in tunnels and substations g Reduction of cooling requirements g Further cost savings. Compatible with existing systems. Minimisation of CO2 footprint. Harmonization and integration with SEPCOS and Sécheron DC switchgear for protection, diagnostics and control. 4 DC Substations / Supply Program

VOLTAGE LIMITING DEVICE (VGuard) During normal operation of railway system, dangerous voltage can occur across accessible points of the return circuit and earth due to the voltage drops along the return circuit caused by the current train traffic or insulation fault. In order to limit these voltages below the admissible values defined in EN 50122 1 standard, a voltage limiting device must be used as a short circuiter between negative and earth. Sécheron s voltage limiting devices (VGuard) are recoverable devices which are compliant with the railway standards: EN 50526 2 (for voltage limiting device) and EN 50122 1 (for protective provision about electrical safety). Combined protection of personnel, passengers and installation. Prevention and elimination of dangerous voltage. Bidirectional operation and protection. Continuous monitoring of the potential of the return circuit. /// TWO MAIN VARIANTS VGuard-B: Basic VGuard with contactor. VGuard-H: Hybrid VGuard with contactor and thyristors. OUTDOOR WAYSIDE PANELS Sécheron has designed its own range of outdoor wayside panels. These cubicles are designed to integrate one or several devices such as disconnect switches, load break switches, contactors or DC high speed circuit breakers. Depending on the customer specification, Sécheron can propose either steel or polyester wayside panels with a protection degree up to IP65. Two basic cooling methods can be applied: natural convection or forced convection. COMPACT DC SUBSTATIONS Sécheron is able to provide customized and complete DC traction substations in containers ready for use (transportable cabins or prefabricated buildings) that are built to withstand severe weather conditions and to shelter the equipment from any environmental influence. Providing the highest security conditions to the operating personnel, Sécheron uses perfectly the internal space of the container substations by incorporating equipment such as AC/MV equipment and traction transformers, DC equipment, rectifiers, DC switchgear, control command and other additional equipment. These containers require minimum installation and commissioning time. Depending on the customer specification, Sécheron can propose different versions of the container construction: either metallic or concrete prefabricated solutions. DC Substations / Supply Program 5

SEPCOS CONTROL AND PROTECTION RELAY SEPCOS is a micro-processor based equipment which satisfies the most demanding safety requirements applicable to DC traction distribution networks. Used as a control and protection unit, SEPCOS integrates the necessary functions for the protection, the control and the measurement of DC traction equipment related to transportation systems (streetcars, underground railways, commuter trains or trolley buses). Moreover, SEPCOS is stand alone, modular, extending, easily adaptable by software and widely open to modern communication equipment (IEC 61850, IEC 62439-3 (PRP/HSR), IEC 60870-5-104 (-5-101), DNP 3.0, Modbus-TCP, Profinet, Modbus-RTU, Profibus-DP). /// DISPLAY The Display allows a complete visualization, control and parameterization of the equipment and collects the information available from the SEPCOS. Control and configuration actions are protected by password levels. /// S-WEB S-Web is an integrated web server within each SEPCOS. This interface is used to configure, visualize and analyze the data. This tool only requires a web browser and does not require any software installation on a computer. MIU10, VM10, VM12, VP10 MEASUREMENT AMPLIFIERS AND RELAYS MIU10, VM10 & VM12 (AMPLIFIERS) The MIU10 isolated amplifier is suitable for measuring high DC currents in power distribution systems for public transport networks. The VM10 and VM12 isolated amplifiers are suitable for measuring DC voltages in power distribution systems for public transport networks. High voltage isolation, wide supply voltage range, low non-linearity error, very high immunity, high galvanic isolation, compact solutions. VP10 (RELAY) The VP10 isolated relay is suitable for the detection of DC voltages in power distribution systems for public transport networks. High voltage isolation, adjustable threshold, high galvanic isolation, intrinsic safety functioning, fuseless solution, diagnostic signal. 6 DC Substations / Supply Program

CONTROL COMMAND & LOCAL SCADA The solution provided by Sécheron for local control and monitoring of traction substations is a significant step in supporting operations and maintenance of the power supply network. In order to meet high demands in reaction time and cost efficiency, the powerful control and supervision system is based on modern communication protocols and combined with user-friendly interface. In addition, all information, events, detection curves, substation history, diagnostic and documents are available to be transmitted to the centralized Scada system of the network. The control command and local Scada developed by Sécheron is a modular system designed for communication and/or control of each part of traction power substations. It allows required interactions between different panels of a substation using specific power network protocols and/or standard industrial network protocols. Supervision of the complete substation: Graphical display of measurement values, positions of breakers, alarm management, trending management, disturbance. Command: Command of all motorized devices including MV breakers and DC breakers. Parameterization: Parameter setting of all protection relays. Control: Possibility to define special control sequences. Wide range of communication protocols. STRAY CURRENT MONITORING SYSTEM The operation of DC traction systems requires suitable measures to prevent corrosion caused by stray currents on railway and non-railway installations. In this scope, the European standard EN 50122-2:2011 (Annex B) recommends a continuous supervision of the rail insulation. Sécheron s Stray Current Monitoring System (SCMS) is a straightforward and efficient method of stray current monitoring avoiding manual repetitive measurement and any interference with the stray current collecting system. The system measures continuously the rail-to-earth potential under operational conditions, complete with central analysis, visualization, signalling and archiving capacities. Set up of network lines and stations, up to 10 lines and 100 control points. Data acquisition and transmission through the communication network. Determination on data reference. Integration of specific algorithm depending on the type of network. Permanent automatic analysis of recorded values and manual analysis possible. Alarm and localization of the detected fault. Export and backup of measured and recorded values. Communication with Scada system. Data collection from VGuard (voltage limiting device). DC Substations / Supply Program 7

SG814318BEN_D02-09.17 Sécheron SA Rue du Pré-Bouvier 25 1242 Satigny - Geneva CH-Switzerland www.secheron.com Tel: +41 (0)22 739 41 11 Fax: +41 (0)22 739 48 11 substations@secheron.com This document is not contractual and contains information corresponding to the level of technology at the date of printing. Sécheron reserves the right to modify and/or improve the product, whose characteristics are described in these documents, as required by new technology at any time. It is the purchaser s responsibility to inform himself, no matter what the circumstances, of the product s maintenance conditions and requirements. Sécheron reserves all rights, especially those arising from our General Delivery Conditions. Copyright 2017 Sécheron SA