Optimised Computational Functional Imaging for Arteries

Similar documents
Optimised Computational Functional Imaging for Arteries

Isogeometric Analysis of Fluid-Structure Interaction

CPM Specifications Document Healthy Vertebral:

CFD simulations of blood flow through abdominal part of aorta

A Workflow for Computational Fluid Dynamics Simulations using Patient-Specific Aortic Models

Clinical Importance. Aortic Stenosis. Aortic Regurgitation. Ultrasound vs. MRI. Carotid Artery Stenosis

Magnetic Resonance Elastography (MRE) of Liver Disease

GE Healthcare. Vivid 7 Dimension 08 Cardiovascular ultrasound system

4D Magnetic Resonance Analysis. MR 4D Flow. Visualization and Quantification of Aortic Blood Flow

Life Sciences Applications: Modeling and Simulation for Biomedical Device Design SGC 2013

Ultrasound. Q-Station software. Streamlined workflow solutions. Philips Q-Station ultrasound workspace software

FOREWORD TO THE SPECIAL ISSUE ON MOTION DETECTION AND COMPENSATION

NUMERICAL STUDY OF BLOOD FLOW IN A VESSEL WITH INCREASING DEGREE OF STENOSIS USING DYNAMIC MESHES

Vessel Explorer: a tool for quantitative measurements in CT and MR angiography

3D Surface Reconstruction of the Brain based on Level Set Method

Optimization of Flow Diverter Treatment for a Patient-specific Giant Aneurysm Using STAR-CCM+ László Daróczy, Philipp Berg, Gábor Janiga

RADIOMICS: potential role in the clinics and challenges

Image Analysis, Geometrical Modelling and Image Synthesis for 3D Medical Imaging

MR Advance Techniques. Vascular Imaging. Class III

Classification of Subject Motion for Improved Reconstruction of Dynamic Magnetic Resonance Imaging

Multimodality Imaging for Tumor Volume Definition in Radiation Oncology

Volumetric Analysis of the Heart from Tagged-MRI. Introduction & Background

Geometrical Modeling of the Heart

Automated segmentation methods for liver analysis in oncology applications

Accuracy of Computational Hemodynamics in Complex Arterial Geometries Reconstructed from Magnetic Resonance Imaging

SIMULATION OF FLOW FIELD AROUND AND INSIDE SCOUR PROTECTION WITH PHYSICAL AND REALISTIC PARTICLE CONFIGURATIONS

Computer-Aided Diagnosis in Abdominal and Cardiac Radiology Using Neural Networks

Correction of Partial Volume Effects in Arterial Spin Labeling MRI

Functional MRI in Clinical Research and Practice Preprocessing

Volumetric Deformable Models for Simulation of Laparoscopic Surgery

Application of level set based method for segmentation of blood vessels in angiography images

Analysis of Cerebral Blood Flow from Small Rodents

BioIRC solutions. CFDVasc manual

SPM8 for Basic and Clinical Investigators. Preprocessing. fmri Preprocessing

Blood Particle Trajectories in Phase-Contrast-MRI as Minimal Paths Computed with Anisotropic Fast Marching

CAROTID ARTERY ATHEROSCLEROTIC PLAQUE DETECTION BY MINIMIZING ENERGY FUNCTION OF THE CONTOUR

Finite Element Simulation of Moving Targets in Radio Therapy

LS-DYNA 980 : Recent Developments, Application Areas and Validation Process of the Incompressible fluid solver (ICFD) in LS-DYNA.

From medical imaging to numerical simulations

Segmentation of Intima Media Complex of Common Carotid Artery

High dynamic range magnetic resonance flow imaging in the abdomen

11/18/ CPT Preauthorization Groupings Effective January 1, Computerized Tomography (CT) Abdomen 6. CPT Description SEGR CT01

This tutorial illustrates how to set up and solve a problem involving solidification. This tutorial will demonstrate how to do the following:

Non-Newtonian Transitional Flow in an Eccentric Annulus

Quantitative IntraVascular UltraSound (QCU)

Image Acquisition Systems

CHAPTER 2. Morphometry on rodent brains. A.E.H. Scheenstra J. Dijkstra L. van der Weerd

Demo problem: Steady finite-reynolds-number flow through an iliac bifurcation

Driven Cavity Example

CFD modelling of thickened tailings Final project report

Lab 9: FLUENT: Transient Natural Convection Between Concentric Cylinders

Skåne University Hospital Lund, Lund, Sweden 2 Deparment of Numerical Analysis, Centre for Mathematical Sciences, Lund University, Lund, Sweden

Applying vessel inlet/outlet conditions to patientspecific models embedded in Cartesian grids

Computer Aided Diagnosis Based on Medical Image Processing and Artificial Intelligence Methods

3D Vascular Segmentation using MRA Statistics and Velocity Field Information in PC-MRA

Medical Image Segmentation

Non-rigid 2D-3D image registration for use in Endovascular repair of Abdominal Aortic Aneurysms.

SIMULATION D'IRM ANGIOGRAPHIQUE PAR EXTENSION DU LOGICIEL JEMRIS

SCIENCE & TECHNOLOGY

Institute of Cardiovascular Science, UCL Centre for Cardiovascular Imaging, London, United Kingdom, 2

Probabilistic Tracking and Model-based Segmentation of 3D Tubular Structures

CFD design tool for industrial applications

FINDING THE TRUE EDGE IN CTA

Development of Hybrid Fluid Jet / Float Polishing Process

EPI Data Are Acquired Serially. EPI Data Are Acquired Serially 10/23/2011. Functional Connectivity Preprocessing. fmri Preprocessing

Large-scale Gas Turbine Simulations on GPU clusters

Simulation of In-Cylinder Flow Phenomena with ANSYS Piston Grid An Improved Meshing and Simulation Approach

AI Models of the Hemodynamic Simulation

ENERGY-224 Reservoir Simulation Project Report. Ala Alzayer

Basic fmri Design and Analysis. Preprocessing

Optical Flow Method for Blood Flow Velocimetry Based on Digital X-Ray Subtraction Angiography: A Brief Review

4D MRI phase-contrast image to determinate blood flow patterns in aorta

MESHLESS SOLUTION OF INCOMPRESSIBLE FLOW OVER BACKWARD-FACING STEP

Analysis Comparison between CFD and FEA of an Idealized Concept V- Hull Floor Configuration in Two Dimensions

Level Set Methods and Fast Marching Methods

GPU Based Region Growth and Vessel Tracking. Supratik Moulik M.D. Jason Walsh

Magnetic Resonance Angiography

3D Volume Mesh Generation of Human Organs Using Surface Geometries Created from the Visible Human Data Set

Automatic Ascending Aorta Detection in CTA Datasets

Beginner s Guide to Vevo 2100

A Registration-Based Atlas Propagation Framework for Automatic Whole Heart Segmentation

US 1.

Simulation of Flow Development in a Pipe

Shape optimisation using breakthrough technologies

Module 5: Dynamic Imaging and Phase Sharing. (true-fisp, TRICKS, CAPR, DISTAL, DISCO, HYPR) Review. Improving Temporal Resolution.

MEDICAL IMAGE ANALYSIS

Phantom-based evaluation of a semi-automatic segmentation algorithm for cerebral vascular structures in 3D ultrasound angiography (3D USA)

2-D Tank Sloshing Using the Coupled Eulerian- LaGrangian (CEL) Capability of Abaqus/Explicit

Accelerated MRI Techniques: Basics of Parallel Imaging and Compressed Sensing

SPM8 for Basic and Clinical Investigators. Preprocessing

coding of various parts showing different features, the possibility of rotation or of hiding covering parts of the object's surface to gain an insight

CHAPTER 4 CFD AND FEA ANALYSIS OF DEEP DRAWING PROCESS

LOGIQ. V2 Ultrasound. Part of LOGIQ Vision Series. Imagination at work LOGIQ is a trademark of General Electric Company.

A Generic Lie Group Model for Computer Vision

High performance MRI simulations of motion on multi-gpu systems

Using a Single Rotating Reference Frame

A Study of Medical Image Analysis System

Fmri Spatial Processing

Redundancy Encoding for Fast Dynamic MR Imaging using Structured Sparsity

Image-based simulation of the human thorax for cardio-pulmonary applications

Transcription:

Optimised Computational Functional Imaging for Arteries Ramiro Moreno 1, Ming Chau 3, Shirod Jeetoo 1, Franck Nicoud 2, Frédéric Viart 3, and Hervé Rousseau 1 1 Institut de Médecine Moléculaire de Rangueil (I2MR), CHU de Rangueil, Toulouse, France moreno.r@chu-toulouse.fr. 2 Institut de Mathématiques et Modélisations de Montpellier (I3M), Université de Montpellier II, France 3 Advanced Solution Accelerator (ASA), Montpellier, France Abstract. The general framework of the Optimised Computational Functional Imaging for Arteries (OCFIA) program is to introduce high-performance scientific computing in the medical domain with the aim to rationalize therapeutic decisions in respect to vascular diseases yet poorly understood. More precisely, it consists in coupling medical imaging techniques, essentially morphological, with scientific computing, through Computational Fluid Dynamics (CFD), to yield functional imaging, thus providing to physicians a better quantitative knowledge of the biomechanical state (field of speeds, pressure, wall and Stent Graft loads...) to the patients. 1 Introduction Risk factors for cardiovascular disease (hypertension and high cholesterol) and their role have been identified, but cannot explain the observed localised occurrence and the progression of the disease (stenosis, aneurysm rupture, aortic dissection). Currently, available techniques such as Computed Tomography (CT), Magnetic Resonance Imaging (MRI) and Ultrasound (US) do not allow accurate determination of the complex velocity distribution and biomechanical load on the arterial wall. Nevertheless there is not doubt that medical imaging is an essential tool for the understanding of these pathological processes. Cardiovascular disease is clearly multi-factorial and it has been shown that deviations of the normal velocity field (changes in wall shear stress) play a key role [Caro,1969]. Despite many hemodynamic studies carried out with models of arterial bifurcations, especially the carotid artery bifurcation, the precise role played by wall shear stress (WSS) in the development and progression of atherosclerosis remains unclear. Still, it is certain that the mechanical load induced by the fluid on atherosclerotic plaques and their surrounding tissues is of the utmost importance for predicting future rupture (culprit plaques) and preventing ischemic events [Corti,2002]. In the same way, the risk of rupture of an aortic abdominal aneurysm (AAA) depends more on biomechanical factors than simply on the aneurysm diameter.

2 Although clinical decisions are based only on the latter today, wall tension is a significant predictive factor of pending rupture [Aaron, 2000]. Computational Fluid Dynamics (CFD) techniques can provide extremely detailed analysis of the flow field and wall stress (shear & tensile) to very high accuracy. New advances in simulation techniques could make a significant contribution to a better quantitative knowledge of the biomechanical condition of the arteries and lead to a new understanding via deepened insights into these conditions. Advanced simulations could potentially be used for predicting plaque and aneurysm rupture, improving endovascular prosthesis design, as well as for guiding treatment decisions by predicting the outcome of interventional gesture (i.e. stent-coil technique). However, applying computational fluid dynamics (CFD) to actual pathological regions of the arterial tree is very challenging and has never been done so far with sufficient accuracy and time efficiency to be useful in the clinical practice. Today s medical research is strongly linked with advances in parallel and high performance computing. Ambitious research programs such as NeuroSpin (Saclay, France) are feasible thanks to the support of the computational ressources of CEA (9968, 63 TFlops, 7th in the top 500 supercomputers). Data storage, visualization and grid infrastructure are also key issues. The development of Virtual Vascular Surgery is encouraged by grid computing consortiums such as Crossgrid. There is no doubt that advances in computational ressources and infrastructure will benefit to the medical community. In return, more and more challenging applications will rise and stimulate research and development. We present a complete, optimized calculation chain whose input come from an entirely non-invasive 4D MRI protocol that provides time varying geometry and flow rates and output is a realistic functional imaging description of the arterial tree region of interest. Preliminar results were obtained through parallel computing with AVBP code (CERFACS, Toulouse, France) and classical Arbitrary Langrangian Eulerian (ALE) formulation. 2 Materials and Methods 2.1 Image acquisition: MRI protocol All the images were obtained with a 1.5 T MR scanner (Intera; Philips Medical Systems, the Netherlands) with a 5-element phased-array coil for signal reception (Sense Cardiac, Philips Medical Systems). The objective of following processing steps was to translate the image data set into patient-specific conditions (boundary conditions) suitable for CFD calculations. MR Angiography The routine injected (Gd-DTPA, Magnevist, Schering, volume injected 20mL, injection rate 5mL/s) T1-Full Field Echo sequence was performed on sagittal-oblique planes, parallel to the major aortic axis, in order to cover the whole aorta geometry (field of view, 450x450x126mm) with a spatial

3 resolution of 0,88x0,88x1.80mm 3. This acquisition was trigged to the patient ECG, 430ms after the R wave (diastolic phase). Single Slice 2D MR Cine Imaging A dynamic balanced Steady State Free precession (b-ssfp) sequence, was performed on transverse planes, to cover the thoracic aorta and segment the cardiac cycle in 20-40 phases. MR flow quantification 2D Phase-Contrast (PC) sequences, performed orthogonal to the vessel axis, provided the velocity inlet profiles at the ascending, descending aorta, and supraaortic vessels. Supplementary transversal-oblique and sagittal-oblique acquisitions, respectively ortogonal to the short and long aortas axis, were performed to compare quantitatively the velocity results from the CFD. 2.2 Image data processing All of the next procedures described in this chapter were developed in-house in a Matlab language (The Matlabworks, Inc) with some C compiled routines (mexfiles) integrated to main sources. Some of them (affine coregistration and high dimensional warping are initially developped by John Ashburner into SPM (statistical parametric mapping toolbox University College London, 2000), an image processing toolbox dedicated to computational neuroanatomy. The images were initially obtained in DICOM format and were converted to the Analyze-7 format (Mayo Clinic, Rochester, USA., http://www.mayo.edu/bir/) for filtering and non-linear-transformation operations. The meshes were initially built in an ASCII format (*.cas) into the Amira 4.1 environement(tgs, Mercury Computer Systems, USA). The final set of moving meshes and hemodynamic boundary conditions are exported into the correct AVBP format (CERFACS, Toulouse, France, http://www.cerfacs.fr) in order to perform CFD runs. Finally, all postprocessing steps before CFD step were operated with a Pentium(R) Duo 3,4 GHz processor with 1.5Go RAM. The geometrical post-processing operations are highlighted on the figure 1. Filtering MR image noise affects the post-processing algorithms. Filtering can be used to limit image noise but current filters reduce spatial resolution. In this work we applied a selective blurring filter to anatomical MR data. The filtered static data acquisition are submited to 3D Level Set algorithm (see section Initial Mesh) for a segmentation step. Compared to other classical filters, this filter achieves the best compromise between spatial resolution and noise reduction [Gensanne, 2005]. The homogeneous regions must have the same gray level, so if the noise (gradient) is less than 2xSNR (95%), the selective blurring filter apply a hard smooth (weighting=1). The treatment is different for the fine details where gradient is greather than 2xSNR the filter gradually weight the smooth according to the image neighbours gradient (weighting=1/gradient).

4 Fig. 1. Postprocessing steps for moving mesh preparation from MRI acquisitions Initial Mesh After this stage of filtering, the anatomical surface can be extracted by means of level-set/fast marching methods [Sethian, 1999] that accurately model the complex surfaces of pathological objects. With the static geometry acquisition, the level set methods offer a highly robust and accurate method for tracking the interface in a volume of interest coming from the static and contrast-enhanced MRI acquisition. Given an initial position for an interface γ 0 (endovascular surface), where γ is a closed surface in R 3, and a speed function F which gives the speed of γ in its normal direction, the level set method takes the perspective of viewing γ as a zero level set of a function φ from R 3 to R whose evolution equation is eq. 1 and where φ represents the distance function. { φt F φ = 0 φ(x, t = 0) = ±d(x) (1) The filtered static data acquisitions (T1-Full Field Echo sequences) are submitted to the in-house 3D Level Set algorithm for a fine geometrical extraction step (Matlab 7.0, the MathWorks, Inc). An initial computational grid was obtained by the discretization of this geometry (Amira 4.1). Moving Mesh Wall movements were imposed to the initial grid according to cine scan acquisition (b-ssfp), by means of the non linear transformation field algorithm of SPM-2 toolbox (Matlab 7.0, the MathWorks, Inc). A tetraedral

5 moving grid was built [Moreno, 2006] according to estimated non-linear deformation fields (Fig. 2 shows the mesh and its deformation on a section). Each phase of the transformation process consists in estimating the defomation between the native and a target image. Therefore, the whole transformation is completed when the deformations to all the target images of a cardiac cycle are computed. The meshes used at each time step of CFD simulation are obtained by applying the computed deformation (according to cine scan images) to the native mesh (obtained from injected sequence). Specifically, the optimization approach is used here. We are trying to find the best compromise between effective transformation, by a function F 2 (eq.3), and regular transformation, by a function F 1 (eq.2) which corresponds to the sum of local volume variations ( V V = J 1). The deformation gradient tensor J is computed according to the coordinates of T (x). Optimization process consists in finding T which minimizes a linear combination of F 1 and F 2 (eq.4). F 1 = Ω F 2 = Ω ( ( J 1) dω + J 1 1 ) dω (2) Ω [I source (x) I target (T (x))] 2 dω (3) F = λf 1 + F 2 (4) The derivative of F is computed with symbolic calculation tool and a gradient algorithm is used. The phases of the transformation process (Fig. 2) can be computed independently. This is a strightforward parallelization. Fig. 2. Moving meshes (2 cardiac phases)

6 Hemodynamic Boundary Conditions A region of interest (ROI) defined the vascular area on the Phase Contrast (PC) quantitative images to extract velocity data samples. A curve fitting calculation was applied to this data set using the general Fourier model in order to obtain a time-dependent function. This process was applied to all the orthogonal sections to the short aorta axis (Fig. 3). The areas corresponding to the ascending, descending aorta and supraaortic vessels provided inlet and oulet conditions for CFD, while the mid descending aorta was used for the control. The arrow on the right side image points out a strongly turbulent flow. Note that these MRI images give the vertical component of velocity. Fig. 3. Phase contrast aquisition for the inlet/oulet velocity evaluation

7 2.3 CFD application A first numerical model was developed [Nicoud, 2005] in order to assess the wall shear stress changes after endovascular stenting. In this approach, the fully coupled fluid structure problem is replaced by a simpler fluid problem with moving boundaries. The NavierStokes equations were solved numerically with an appropriate finite-element-based method which handles time-dependent geometries. The main result supports the idea that stenting can induce endothelial dysfunction via haemodynamic perturbations. From this study, which enabled us to check the feasibility of an uncoupled CFD, we widened the problem with the more complex case of vascular geometries. The flow simulations were performed using the finite volume (FV) method, as implemented in the AVBP code (CERFACS, European Center for Research and Advanced Training in Scientific Computation, Toulouse, France). The FV method used in the code solves the full Navier-Stokes equation, who governs the flow, by an efficient explicit Arbitrary Lagrangian Eulerian (ALE) formulation (Fig. 4), which allows to impose the tetraedral moving grid within cardiac cycles. Fig. 4. Total mesh volume : run process (one ALE run per cardiac phase) for HPC Hemodynamic conditions (time-dependent functions) were synchronized with the wall motion and were imposed in the form of speed profiles at the entry (ascending aorta) and exit (descending aorta, supraortic vessels) of the numerical field (aorta district). Blood was assumed to be a homogeneous newtonian fluid with a dynamic viscosity approximated as 4 cpoi and a density of 1050 kg/m3 (physiologic blood value in aorta and collaterals). The simulations began from an initially quiescent flow state and continued for a number of full cardiac cycles in order to allow the development of a fully periodic flow, representative of a regular heartbeat. It was found that the main features of the vascular flow field became stable within four cycles.

8 Uncoupled CFD results were performed in HPC system (IBM, Power4, Cines, Montpellier, France) and were controlled by the additional MRI quantitativeflow-imaging performed at intermediate levels during the examination. Geometric deformation field was validated by 3D visual correlation between moving mesh and cine scan imaging. Tetraedral Grid Resolution (minimum length: 1mm; maximum lenght 2.3 mm), balanced between the grid independence and time efficiency conditions, was sufficient for preliminar results on Carotid Bifurcation and Thoracic Aorta CFD calculations. 3 Results Thoracic aorta studies were performed in both volunteers and patient cases (Fig.5). Boundary conditions were flow controlled and Risk Factors were observed in relation with hot spots in wall stress and hemodynamic results (shear stress, velocity and vorticity). Patient data set was treated in 24 hours, according to the description of the table 1. The data processing is virtually automatic, the only manual interventions are corrections of errors of the native geometry and preparation of boundary conditions during the extraction process. Normal WSS values calculated by CFD on healthy ascending regions on patients were similar to data available on literature [Efstathopoulos, 2008] performed on healthy subjects by phase-contrast MRI flow measurements and straightforward methodologies based on Poiseuille s theory of flow. Systolic (0.3 ± 0.2 N/m2 compared to 0.4 ± 0.2 N/m2) and diastolic (0.065 ± 0.04 N/m2 compared to 0.11 ± 0.07 N/m2). The same group of patients presented abnormal WSS values on landing zones (+12% at systole, +35% at diastole), plicatures zones (+38% ± 6% at systole and +25 ± 11% at diastole) and collateral (neck vessels) zones (+6 ± 2% at systole). Table 1. Time consuming for the general clinical case Chain element process MRI protocol. Level Set geometry extraction (not parallel). Native mesh prepartation and correction (interactive, manual). Moving mesh estimation process (not parallel). Moving mesh estimation process (parallel@2proc). CFD (HPC, 24 proc). TOTAL Time consuming 30 min 60 min 120 min 600 min 300 min 600 min 1410 min (23h30 min)

9 rigid wall vrs moving wall numerical results 300 ml/s 250 200 150 moving wall numerical result MRI flux rigid wall numerical result total flux 100 50 0!50 0.8 0.9 1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 time (s) Fig. 5. Stented thoracic aorta : wall shear stress, stream lines velocity, control fow at intermediate level for rigid and moving wall.

10 Table 2. Run characteristics parameter value number of tetraedral elements 145848 number of iterations for convergence 2.6182e+08 fixed time step for moving wall 0.55E-04 s time step for rigid wall 0.32E-04 s delta Volume for moving mesh 84 ml 4 Discussion Following the extraction from the Level Set method, we found that it was restrictive to make weary calculations to extract the initial geometry. Sethian s method is indeed very interesting but it depends heavily on the image quality. Partial volume artefacts increase with the thickness of the slice for a given imaging volume and results in blurring in regions where several vessels cross. An extraction method with the Level Set technique is erroneous because it sees a single vessel rather than distinguishing them. We try to solve this problem by asking experienced radiologists to make the geometry extraction through a threshold setting procedure. It revealed to be very efficient, the extraction being made instanteneously with the possibility for error correction by the user. The flow curves obtained in the reference plan reveals the importance of taking into account the mobile wall in a realistic case. The result obtained in a rigid mesh is far better compared to the MRI measures. Yet the results obtained on a moving mesh are very similar to the control measures. It seems obvious that a realistic calculation needs to be done according to the rheology of the wall. The calculations of deformation fields require a single pair of reference volumes (source and template). The computations have been performed on a dualcore processor (table. 1). The N deformations to be computed are dispatched on the processors. As they are independant, no communication is required during the parallel computing. It is thus trivial to reduce the time to 1/n if we have such processors at our disposal. 5 Conclusion The proposed approach permits the computation of the blood flow under realistic in vivo, time evolving and flow controlled conditions. It is much simpler than the full coupled fluid-structure problem and has the potential to provide a better picture of the specific hemodynamic status. The method gives a direct way to impose realistic wall interaction to hemodynamic time boundary conditions, from medical examinations performed into a simple MR protocol. A future improvement in the processing chain described in this work will facilitate biomechanical functional imaging in less than 8 hours, which would be useful

11 for clinical practice. Insights about the physiopathology of some arterial diseases and endovascular treatment are also expected. References [Caro,1969] Caro, C., Fitz-Gerald, J., Schroter, R.: Arterial wall shear and distribution of early atheroma in man. Nature 211. 223 (1969) 1159 1160. [Corti,2002] Roberto Corti, MD, Lina Baldimon, PhD, Valentin Fuster, MD, PhD and Juan Jos Badimon, PhD: Endothelium, flow, and atherothrombosis, Assessing and Modifying the vulnerable atherosclerotic plaque, American Heart Association, ed Valentin Fuster (2002) [Aaron, 2000] Aaron J. Hall, Edward F.G. Busse, Don J. McCarville, John J. Burgess.: Aortic wall tension as a predictive factor for abdominal aortic aneurysm rupture: improving the selection of patients for abdominal aneurysm repair. An Vasc Surg.142 (2000) 152 157. [Gensanne, 2005] D Gensanne, G Josse and D Vincensini, A post-processing method for multiexponential spinspin relaxation analysis of MRI signals. Physics in Medecine and Biology. 50 (2005)1 18. [Sethian, 1999] J. A. Sethian, Level Set Methods and Fast Marching Methods, Cambridge University Press (1999). [Nicoud, 2005] F. Nicoud, H. Vernhet, M. Dauzat, A numerical assessment of wall shear stress changes after endovascular stenting, Journal of Biomechanics. 38 (1999) 2019 2027. [Efstathopoulos, 2008] Efstathios P. Efstathopoulos, George Patatoukas, Ioannis Pantos, Odysseas Benekos, Demosthenes Katritsis, Nikolaos L. Kelekis. Measurement of systolic and diastolic arterial wall shear stress in the ascending aorta, Physica Medica (2008). [Moreno, 2006] R. Moreno, F. Nicoud, H. Rousseau. Non-linear-transformationfield to build moving meshes for patient specific blood flow simulations. European Conference on Computational Fluid Dynamics, ECCOMAS CFD 2006. http://proceedings.fyper.com/eccomascfd2006