Customer Responsibilities

Similar documents
Customer Responsibilities

Customer Responsibilities

Customer Responsibilities

Customer Responsibilities

Customer Responsibilities

Customer Responsibilities

Customer Responsibilities

Customer Responsibilities-networked

Customer Responsibilities

OpenLAB Site Preparation CDS Distributed Checklist ChemStation (C.01.06) AIC s, CDS Clients, Instruments. Customer Responsibilities

Customer Responsibilities-networked

OpenLAB Site Preparation CDS Distributed Checklist EZChrom (A.04.06), AIC's, CDS Clients, Instruments. Customer Responsibilities

Customer Responsibilities

OpenLAB Data Store Server A Site Preparation Checklist. Purpose of Procedure. Customer Responsibilities

Purpose of Procedure. Customer Responsibilities. Important Customer Information. OpenLAB Data Store Server A Site Preparation Checklist

Agilent 2100 Bioanalyzer System & Applications Site Preparation Checklist

GEMS Software System Requirements Frequently Asked Questions

Tips and Tricks: Installing Sage Pastel Accounting

Customer Responsibilities

Customers should provide all necessary operating supplies upon request of the engineer.

Frequently Asked Questions UNIFI v1.9 Service Release 4 Upgrade

Reliable High-Speed Connection to Publication Database for Synchronization

Customer Responsibilities

CHECKLIST FOR IT AND SECURITY PERSONNEL

Spectroscopy Configuration Manager (SCM) Software. 21 CFR Part 11 Compliance Booklet

Copyright Autodesk, Inc.

Pulse 4.11 SCADA/HMI. Installation Guide

Get to know SysKit Monitor

Sage 300 People & Web Self Service Technical Information & System Requirements

UNICORN Administration and Technical Manual

Agilent OpenLAB Chromatography Data System (CDS)

Centrix WorkSpace Discovery Installation Guide. Version 1.0

Minimum System Requirements for Horizon s new Windows Product

SICAT SUITE VERSION 1.1. Instructions for use English

Standard System Specifications

URGENT IMPORTANT FIELD SAFETY MODIFICATION

Sage 50cloud Pastel System Requirements

Ontrack PowerControls V7.2 for SharePoint ReadMe

Customer Responsibilities

INSTALLATION AND SET UP GUIDE

Recommended System Requirements for Microsoft Dynamics SL 2018

3M Molecular Detection System Software Upgrade/Installation Instructions

Sage ERP Accpac. Compatibility Guide Version 6.0. Revised: February 2, Version 6.0 Compatibility Guide

Code Alert Customer Information Technology Requirements Series 30 Software

IT and Interface Requirements

Hardware and Software Requirements for Server Applications. IVS Enterprise Server Version 12.5+

DefendX Software Control-Audit for Hitachi Installation Guide

ProteinChip Software Installation and Setup. Data Manager

SICAT SUITE VERSION 1.0. Instructions for use SIDEXIS XG English

Dell Client Manager 2.0 FAQ

F-Secure Client Security. Quick Installation Guide

Agilent OpenLAB ECM Intelligent Reporter

Tivoli Inventory 4.0 Provides A Cross-Platform Automated Solution For Inventory Management

System recommendations for version 17.1

Geneva 10.0 System Requirements

INSTALLATION AND SET UP GUIDE

NTP Software File Auditor for Hitachi

Monsoon System Requirements

Patch Manager INSTALLATION GUIDE. Version Last Updated: September 25, 2017

Installation Instructions

General System Requirements for Process Safety and Conceptual Engineering Software

Self-Hosted Hardware and Software Full Requirements

Infrastructure: Local/Client Hosted

Proficy* Workflow. Powered by Proficy SOA GETTING STARTED

InventoryControl Quick Start Guide

MINIMUM HARDWARE AND OS SPECIFICATIONS File Stream Document Management Software - System Requirements for V4.2

Version 2.8. Installation Guide

Symantec System Recovery 2013 Management Solution FAQ

Deltek Vision 7.4 Technical Overview & System Requirements: Basic Deployment ( Employees) 1/28/2015

Release 3.0 Network Installation Overview

INSTALLATION GUIDE. RAPID TAG PC-Based Software Installation Guide. Version 5.0

SICAT SUITE VERSION 1.0. Instructions for use English

Unity Loader V14.0 Readme

Installing and Setting Up the Snap-on EPC. Rev.1.6 (12 Apr 2012) PN EN

Sage 300 ERP. Compatibility Guide Version Revised: Oct 1, Version 6.0 Compatibility Guide i

Report Exec Dispatch System Specifications

COACH Installation Guide

Proficy* Workflow. Powered by Proficy SOA GETTING STARTED

MYOB Enterprise Solutions

ebob v5.2 Operator s Manual

Installation Guide. EventTracker Enterprise. Install Guide Centre Park Drive Publication Date: Aug 03, U.S. Toll Free:

INSTALLATION GUIDE. RAPID TAG EVAC PC-Based Software Installation Guide. Version 5.0

Release Notes SmartSystems Server v4.80

Requirements and Dependencies

Symantec System Recovery 2011 Management Solution Technical FAQ

MYOB ENTERPRISE SOLUTIONS. System Requirement Guidelines EXO BUSINESS. Version 2.9 Thursday 1 st May 2014 MYOB ENT ER P R IS E S OLUT IONS

Delphi 2015 SP3-AP4. System Requirements. amadeus-hospitality.com

Smart HUB - HUB to expand one Master Controller s RS-485 port to 8 RS-485 ports - Use 12VDC power

HARDWARE REQUIREMENTS. Revised February 13, POWERING SUCCESSFUL PRACTICES TM

Sage ERP Accpac. Compatibility Guide Version 6.0. Revised: November 18, 2010

Safe Place and Code Alert Customer Information Technology Requirements Series 10.x Software

Installing Windows Server Heng Sovannarith

1 Hardware requirements pg 2. 2 How to install Sage Pastel Xpress Version 12 pg 2. 3 Starting Sage Pastel Xpress Version 12 pg 6

Pre-installation Guide. Collect v1.0 Technical Installation Guide

IM5546 IceSpy Notion Pro. Pre-Requisites Manual

Deployment Guide Installing WhatsUp Gold Distributed Edition to Central and Remote Sites

ReadMe. exlhoist Configuration Software V1.0

Contains the Following Improvements over Prior Release:

Product Release Notes for Avaya Proactive Contact Supervisor

Agilent MassHunter Workstation Software for Triple Quad LC/MS

Transcription:

Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation of your Agilent Cary WinUV Pharma software, please refer to this specification and set of requirements. Correct site preparation is the key first step in ensuring that your instruments and software systems operate reliably over an extended lifetime. This document is an information guide and checklist that outlines the supplies, consumables, space and utility requirements for your equipment. Customer Responsibilities Make sure your site meets the following specifications before the installation date. For details, see specific sections within this checklist, including: The computing environment and the necessary space is made available The number & location of electrical outlets for your computer systems and peripherals are planned That your site meets the software, hardware and networking specifications below Locate your sales order information, software authorization codes and/or software licenses/certificates The necessary software media, disks etc. are available including upgrade/update disks That a suitable backup solution is identified for your software Availability of a system/network administrator as needed to connect to your network and configure the system Please consult Other Requirements section below for other product-specific information. If Agilent is delivering installation and familiarization services, users of the instrument should be present throughout these services; otherwise, they will miss important operational, maintenance and safety information. For more details about the installation requirements of Cary WinUV Pharma, please consult the following documents for your version of Cary WinUV Pharma: o Agilent Spectroscopy Configuration Manager System Requirements o Agilent Cary WinUV Pharma Software Installation Instructions for 21 CFR Part 11 Environments o And the Spectroscopy Configuration Manager (SCM) Software, 21 CFR Part 11 Compliance Booklet o Agilent Cary WinUV version 5_1_0 Release Notes Additional, up-to-date information is available in the Agilent Cary WinUV Pharma SSB. These documents will be provided to you with the purchase of your Cary WinUV Pharma software but please ask your Agilent representative to provide them to you for review before purchase or arrival for installation by your Agilent representative. 1 Page 1 of 10

Important Customer Information 1. If you have questions or problems in providing anything described as a Customer Responsibility above, please contact your local Agilent or partner support/service organization for assistance prior to delivery. In addition, Agilent and/or its partners reserve the right to reschedule the installation dependent upon the readiness of your laboratory. 2. Should your site not be ready for whatever reasons, please contact Agilent as soon as possible to re-arrange any services that have been purchased. 3. Other optional services such as additional training, operational qualification (OQ) and consultation for user-specific applications may also be provided at the time of installation when ordered with the system, but should be contracted separately. 4. You should ensure that all necessary operating supplies for the successful installation of instruments and systems are available. Installation sites should be prepared in accordance with the information outlined in this document. Important Version and Hardware Information 1. Please refer to Table 1 for supported Cary WinUV and hardware configurations. Table 1. Supported Hardware, Software and Firmware Combinations Supported Cary WinUV Pharma and Instrument Configurations Cary WinUV Version Cary Pharma Version Supported Instrument Hardware 5.1.0.1019 1 5.1.0.1020 1 5.1 2 Agilent Cary 60 3 Comments 1. FW 6.4.0.141 2. English only 3. Cary 50 is not tested or supported for this release 2 Page 2 of 10

Software Specifications for Workstations, Clients, and Servers (Pharma) 1. Implement a backup strategy or backup all of your data before making any changes. 2. No other instrument control software must be installed. 3. A user logon with full administrative capabilities is required. 4. Upgrading from Cary WinUV Pharma version 5.0.0.1004 or earlier will require updates to the PC or operating system. This means an upgrade cannot be installed over an existing installation. 5. If upgrading from Cary WinUV Pharma 5.0.0.1005 or later, Cary WinUV does not need to be uninstalled. However, you must manually uninstall both the SCM and SDA applications. Please follow the upgrade instructions in the Agilent Cary WinUV Pharma Software Installation Instructions for 21 CFR Part 11 manual. Failure to follow the instructions exactly may require the PC needing to be reimaged. 6. Upgrading the Cary WinUV Pharma software requires backing up SCM settings and SDA databases so they can be used for the new system. Make sure the instructions in the manual above are followed otherwise data/setting loss will occur. 7. There are some administrative tasks that need to be performed before and after installation of Cary WinUV Pharma - refer to Table 2 and the rest of this document. Table 2. Supported Operating Systems and Settings Specification Description Operating system type(s), versions Account settings/privileges Microsoft Windows Updates Power Saving SQL Server Supported 1, 2, 3 Windows 7 Professional (SP1) 1, 2, 3 Windows 7 Enterprise (SP1) 1, 2, 3 Windows 10 Professional 1, 2, 3 Windows 10 Enterprise 1, 3, 4 Windows Server 2008 R2 SP1 Windows Server 2012 R2 1, 3 Full Local Administrator Rights Outstanding updates must be completed or must not start before installing software Not supported Microsoft SQL Server 2014 Express Ed. Comments 1. 64-bit only 2. Cary 60 only 3. English only for Pharma 4. Manual install of.net Framework 3.5 SP1 required Required for installation, configuration, upgrade or modification Disconnect the PC from the network while performing the installation and configuration Any PC power saving functions should be disabled The Hardware and Software Requirements for Installing SQL Server 2014 must be met 3 Page 3 of 10

Cary WinUV Pharma Scenario Options 1. Cary WinUV Pharma allows for installation in different scenarios (Table 3) 2. The scenario chosen depends on the desired configuration for collection of data and control of electronic records using the Pharma application. 3. Scenario 1 is for local computer installations (using local or domain users) 4. Scenario 2 and 3 is for installation over a network 5. You must decide on the scenario being used for your installation before your Agilent representative arrives onsite. 6. For Scenarios 2 and 3, your IT support personnel must be present during the installation and configuration. If they are not present, it is possible that installation cannot be completed in the allotted time and this may result in extra charges. 7. Refer to the Table 3 for the Scenario options 8. Terminology: a. The software used to run the instrument is known as the 'application software'. b. Spectroscopy Configuration Manager (SCM) provides you with a tool to manage your 21 CFR Part 11 environment by allowing you to create, configure and maintain data in relation to system security, user management and data paths. c. Spectroscopy Database Administrator (SDA) provides a database environment to store and maintain your data. d. The IT Server (Scenario 2/3): is the computer where the data is stored e. The Laboratory Management Computer (Scenario 2): is where the users, profiles and privileges are managed 9. Installation outside of the instructions provided will require external IT support and independent validation. Table 3. Scenarios Options Scenario 1 All software is installed on the computer connected directly to the instrument Application software is installed on the instrument computer Scenario 2 SCM is installed on the laboratory management computer SDA is installed on an IT server. Application software is installed on the instrument computer Scenario 3 SDA and SCM are installed on IT server. 4 Page 4 of 10

Software Specifications for Cary WinUV Pharma (Standalone) 1. Implement a backup strategy or backup all of your data before making any changes. 2. Before you install your software, please check with your network administrator that the computer has a unique name that will not be changed in the future. If the computer is to be connected to a domain, please ensure that this is completed before installing your software. 3. Agilent strongly recommends that your software is installed while logged in as a domain user with administrative privileges. 5 Page 5 of 10

Software Specifications for Cary WinUV Pharma (Network) 1. Implement a backup strategy or backup all of your data before making any changes. 2. Before you install your software, please check with your network administrator that the computer has a unique name that will not be changed in the future. If the computer is to be connected to a domain, please ensure that this is completed before installing your software. 3. It is essential that support from an IT representative is available. They will need to assist in allowing the required access to the domain, the creation of domain groups and the assignment of users to their target groups if required. See Table 4 for more information. 4. A user with local administrator rights for the IT Server and for the Workstation is required so configuration can take place. 5. A Domain user used for the installation must exist and the global groups to handle Cary WinUV users must be available. 6. A global account for the Cary WinUV administration is required. 7. The target computers for the installation must be members of the Domain. 8. The domain server and the server for the data must be different machines. 9. Please review the document "Agilent Cary WinUV Pharma Software Installation Instructions for 21 CFR Part 11" for further information. 10. Having Cary WinUV operate within a Cary WinUV Pharma in a network environment, requires some configuration tasks on the Cary WinUV Pharma Server. Table 4. Important Network Requirements Specification Description Agilent Spectroscopy Configuration Manager System Requirements Supported Microsoft Windows 2008 Active Directory Single Forest / Single Domain model environment Comments Network Active Directory/Domain Users Yes 1 1. Active Directory is required if using network domain users 6 Page 6 of 10

Required Configuration Items 1. Particularly in the case of network installations, several software services and applications must not be prevented from running or getting access through the computer firewall. 2. Implement a backup strategy or backup all of your data before making any changes. 3. Before you install your software, please check with your network administrator that the computer has a unique name that will not be changed in the future. Changes to this configuration item after installation and configuration will result in a non-operational system. This is not covered under any warranty services and extra costs may be involved if a site visit is required to rectify this. 4. If the computer is to be connected to a domain, please ensure that this is completed before installing your software. 5. Agilent requires that your software is installed while logged in as a domain user with administrative privileges. Table 5. Configuration Items Specification Description Region and Language settings/compatibility English Supported.Net Framework Microsoft.NET Framework 3.5 or 4.5.1 Add as exceptions to the Windows Firewall sqlservr.exe sqlbrowser.exe nxserver.exe configmanager.exe Comments Only English is supported for Pharma It may also be necessary to open firewall ports: TCP 1433 and UDP 1434 7 Page 7 of 10

Computer Hardware Specifications for Workstations, Clients, and Servers 1. This is provided as a guide only. 2. The PC configuration must be listed in the Microsoft Windows Marketplace Tested Products List Hardware section for each respective operating system. If your PC hardware is not tested, then the system may not work with the supported operating system. 3. The software runs on systems with sufficient random access memory (RAM) installed. Depending on the usage of the system and the desired data throughput, those systems may not exhibit acceptable performance. 4. In all cases, an appropriate amount of virtual memory should be configured. 5. Some scheduled or background processes like virus checking or defragmenting may cause instrument communication or other performance problems. To avoid these kinds of problems it is required to disable any scheduled events and minimize or eliminate any background processes. Table 6. Recommended Minimum PC Specification Description Minimum Recommended Comments Processor type & speed 3 GHz Quad Core RAM Internal Storage/devices/media Screen Resolution 4 GB (2 GB for Microsoft Windows 7) DVD-ROM Drive Super VGA 800 x 600 Video Graphics Adapter 16-bit colors, 1MB video RAM Printing devices >Super VGA Default Printer >4GB is recommended No default printer could result in reporting and other errors. Pointing devices Computer Mouse Microsoft Compatible Interface USB 2.0 or greater Required for Cary 60 instrument communication Hard Disk 250 GB >250 GB is recommended LAN 100/1000 MBIT Required for network connectivity 8 Page 8 of 10

Other Requirements 1. Important web links Microsoft Hardware Compatibility Lists http://www.microsoft.com/whdc/hcl/default.mspx Links to specific O/S fixes, updates needed http://support.microsoft.com/ 2. For the Cary 60 there is no need to manually load the firmware onto the Cary 60 as this is automatically done once the instrument is connected to the Cary WinUV software. This means that the Cary 60 will always have the appropriate version of firmware that was used/tested with the software. 3. Cary 50 is not tested or supported for this version of Cary WinUV 4. Cary WinUV Pharma for this release uses Microsoft SQL Server 2014 Express Edition and Microsoft.NET Framework 3.5 or 4.5.1 (if they are not already installed on your computer). Other versions of SQL Server may work but have not been tested or validated by Agilent. 5. The Software Status Bulletin, SSB, contain other important information for this release of Cary WinUV. 6. For addition important information please read the Release Notes that come with your software. 9 Page 9 of 10

Important Customer Web Links For additional information about our solutions, please visit our web site at http://www.chem.agilent.com/en-us/pages/homepage.aspx Need to get information on your product? Literature Library - http://www.agilent.com/chem/library Need to know more? Customer Education http://www.agilent.com/chem/education Need technical support, FAQs? http://www.agilent.com/chem/techsupp Need supplies? http://www.agilent.com/chem/supplies Document part number: G6860-90010 10 Page 10 of 10