Grand Hyatt Rio De Janeiro Integrated Room Automation 1 R. Huber / PM RA
Room Automation Integral Part of a Sustainable Building Comfort Function Energy Efficiency 2
An approach to Sustainablility 3 Factors for Sustainable Buildings ecological Sustainability economical Sustainability Social-cultural and functional quality 3
How to save energy? The biggest potential for energy savings in buildings is within the rooms!!! Pictures : Herzog & de Meuron 4
How to optimize? Integrated room automation creates an optimal comfort and well-beeing for the guest at lowest energy consumption!!! Picture : Herzog & de Meuron 5
Effectivity doubled! Picture : Herzog & de Meuron Reduced energy consumption + Increased comfort and well-beeing = Save money!!! 6
It is our Mission to stabilize the sustainability triangle! 7
Overview Room Controller ecos 5 Room operating units ecounit Flexible space layout SAUTER CASE Suite 8
Room Automation Application areas Office Buildings Hotel, Restaurant Cultural facilities Museum, theatre, concert- and opera halls Shopping malls, trade show halls Schools, Universities Health care facilities hospitals, special-care home Airports, railway stations Data centres Cruise ships Laboratory and pharmaceuticals sector 9
Integrated Room Automation is: Part of the building automation system Integrates all automation functions in a room: Room climate (HVAC) Sunshading Lighting Safety, protection (light, sun blinds, windows) Supports flexible space layout 10
The triangle of Integrated room automation An approach based on the user needs room functions 11
Building automation with SAUTER EY-modulo 5 Integral solution from field devices up to the building management system Seamless integration on all levels Open BACnet/IP system Easy integration of third party systems (e.g. hotel booking, security, safety) Optimal network performance One network standard for management level, primary installations (HVAC) and room automation Highest level of safety and efficiency Using proven ethernet network components Fast response time even when communication via several room controllers Efficient installation, commissioning and operation of the system Significant energy savings 12
System Topology 13
Overview Room Controller ecos 5 Room operating units ecounit Flexible space layout SAUTER CASE Suite 14
Room Automation EY-modulo 5 ecos 15
EY-modulo 5 ecos Features Integrates controls of Climate Lighting Sunshading Up to 4 rooms per controller ecos500 Free programmable Expandable with ecolink Remote I/O Modules BACnet/IP EnOcean wireless interface with ecomod580 Systemintegration via BACnet/IP: DALI (lighting), SMI (Venetian blinds). Efficient engineering/commissioning with SAUTER CASE Suite 16
EY-modulo 5 ecos BACnet/IP Features Profil B-BC: BACnet Bulding Controller BACnet BTL zertifiert BACnet Objects: 256 I/O Objects 32 Schedule-Objects 8 Calendar-Objects 16 Trend-Objects, 2000 entries Ethernet 2-Port Switch Line topology, reduced cabling Wiring with standard RJ-45 patch cables, up to 100m per patch Switch 18
EY-modulo 5 ecos ecolink Remote I/O modules reduced wiring Flexible I/O expansion of ecos 5 Up to 16 ecolink modules Family ecolink51* 24V power supply Application: fan coil units, chilled ceilings 16 ecolink Family ecolink52* 230V power supply Application: lighting, sunshade elements 4 ecounit 19
EY-modulo 5 ecos Accessories Terminal cover Replaces local wiring boxes Supports installation of cord grips Protection against direct contact Transformator 230 V~ / 24 V~ 42 VA For DIN Rail mounting 20
Overview Room Controller ecos 5 Room operating units ecounit Flexible space layout SAUTER CASE Suite 21
EY-modulo 5 ecos Room operating ecounit 3 1 2 EY-RU31*: Temperature sensor Rotary know for setpoint selection Occupancy push button Fan control 0-I-II-III-Auto 2 push button e.g. Light on/off LED indicators EY-RU34*: +/- button for setpoint selection LCD display setpoint, room temperature or time Icons: occupancy, fan stage, heating, cooling, units 1 2 3 3 EY-SU306: 6 additional push buttons Functionality defined by the room controller 22
EY-modulo 5 ecos Room operating units EY-RU31x EY-RU34x EY-SU306 23
EY-modulo room units Unlimited possibilities Fits into frame series of switch manufacturers Huge variety of designs /colours Combine with standard light switches Label inserts fully customizable Design your icons Choose any colour Adapt to wallpaper pattern 24
EY-modulo room units Wireless ecounit 1 Full range of wireless room units based on the EnOcean Standard Energy Harvesting w. integrated solar cell Design / funcitonality / mounting same as ecounit 3 Mixed operation w. ecounit 3 possible Integration of third party EnOcean devices e.g. window contacts/handles, light switches EY-RU146 EY-RU146, EY-SU106 EY-RU110 25
EY-modulo room units Hyatt Design Functional compatible to standard SAUTER room units Design optimized for BERKER K.1 series of switches and sockets Icons and push buttons designed by Hyatt 26
Overview Room Controller ecos 5 Room operating units ecounit Flexible space layout SAUTER CASE Suite 27
EY-modulo 5 ecos Flexible space layout There is a permanent change of a buildings usage New tenants require revised floor plans Restructuring or change of work technology Conversion of buildings The space layout is changed several times Short conversion time, at low costs Low level of disturbance due to noise and dust No restriction in usage for other tenants/users Flexible floor plans by means of room segments No rewiring, no change in programming Configure rooms at building management level with novapro Open No interruptions of operations 28
EY-modulo 5 ecos Flexible floor plan Typical application areas of fixed floor plans Hotels Schools Typical application areas of flexible floor plans Offices Conference center Shopping malls 29
EY-modulo 5 ecos Flexible floor plan Segment: smallest functional unit for room automation functions (room segment, window grid) Room: consists of one or more segments (individual room or zone in a open-plan office) Property Building Area Room Segment Raum Bereich Gebäude Liegenschaft VDI3813: Schalenmodell 30
EY-modulo 5 ecos Flexible floor plan novapro Open: During operation of the building: M S S M M M M configure rooms with a mouse click Rooms are symbolized with different colours A room is always a master and several slaves Thanks to the open BACnet standard the configuration of rooms is also possible with a standard BACnet browser 31
Overview Room Controller ecos 5 Room operating units ecounit Flexible space layout SAUTER CASE Suite 32
SAUTER CASE Suite Scope The SAUTER tool chain for: Engineering Programming the control loops, visualization and optimization functions Commissioning Documentation Service 33
SAUTER CASE Suite Features Comprehensive libraries with proven Solutions: Plant Solutions Build in strategies and methods for Energy efficiency Easy to adapt to the project needs Continuous function chart Configuration and parameter settings Graphical representation of closed-loop control systems Programming similar to IEC61131-3 Project management with a common project data base 34
The basis Our customers can rely on SAUTER Room management = Efficient interaction of all trades Room climate Lighting Sunshading Merged to a common functionality for energy efficient solutions 35
References: Office, Appartement Kingsgate, London GB Palais an der Oper München NuOffice, Munich D Paleis van Justitie Amsterdam Florentinum, Prague CZ Rue de Prony, Paris F 36
References: Hotel Hyatt Place Yerewan, Armenia Hyatt Place Amsterdam, NL Hyatt Regency, Duesseldorf, D Le Mériden, Etiler Istanbul, Turkey Hyatt Place Dubai, UAE Absheron JW Marriott Baku, Azerbaijan 37
Grand Hyatt Rio De Janeiro Configuration Function Room/Hall light Bed light Washbasin light W.C. light Mirror light Bath light Reading light left/right Do not disturb switch Make up the room switch All off light switch Door contact switch Door bell switch Hall/Room Presence detector Bathroom presence detector DI Switch 10 10 3 - Curtains up/down switch left, right 4 4 2 Relay Command light AI Triac Room temperature EGt330 1 Power Plug TV 1 Fan Coil: Power, 3 speed Fan Cold water valve; Electrical heater 5 1 Required I/O 19 20 1 1 38
Grand Hyatt Rio De Janeiro Configuration Function DI Relay AI Triac Required I/O 19 20 1 1 ecos500 11 16 1 8 2 x ecolink521 8 4 - - 39
Looking forward to realize the next project for you. 40