Surge Current Capacities

Similar documents
White Paper Surge Current Characteristics: 570 Hybrid Surge Protective Device

National Standard of The People s Republic of China

MDSP-Series 90kA, 150kA, 300kA Modular Distribution Surge Protector Type 2 Class II Surge Arrester

AC Line Voltage Transients and Their Suppression

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

Data Sheet. Surge protection devices - A technical overview

ENGR. MARITES R. PANGILINAN, P.E.E.

Application Note TAN MTL Surge Technologies. Lightning surge protection for electronic equipment - a practical guide.

2 Principle of lightning protection

glossary GE Digital Energy Power Quality Surge Protective Devices (SPDs)

AC Line Voltage Transients and Their Suppression

GLOSSARY OF TERMS. Surge and Lightning Protection ERICO Inc.

LIGHTNING PROTECTION

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

TDX Series. Transient Discriminating TM TVSS

SPM Series Plug-in Surge Protection

Characterisation of surge suppressors

LIGHTNING PROTECTION of SCADA AND TELEMETRY SYSTEMS

Session Two: Effective Surge Protection Installation

METAL OXIDE VARISTORS

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

Tel: Web: Lightning and surge protection help pages

TDS Transient Discriminating Surge Diverters

MSP Reliability White Paper Bourns, Inc. Hans-Wolfgang Oertel Vice President of Technology

Revised Standards Provide Design Options for Primary and Secondary Protection TELECOM PROTECTION WHITE PAPER

TECH NOTE #: CPS-1 SUMMARY OF APPLICABLE UL AND IEEE STANDARDS

CONNECT AND PROTECT. nvent ERICO Critec SRF N-Series. Surge Reduction Filters

White Paper. AC Surge Protection. Evaluation of Series Element Surge Protective Device for Protection of Electronic Equipment and Systems

MONITORING ABSTRACT KEYWORDS. TRANSFORMERS MAGAZINE Special Edition: Bushings, 2017

Fundamentals of Thyristor Overvoltage Circuit Protection

The Development of Hybrid Surge Protection Circuit with Effect of Adding a Filter

Systems which use a conventional POTS subscriber line to dial a compatible system and transfer digital data.

SPM Series. Plug-in Surge Protection

Commercial and Industrial LV Power Protection

The Wave Breaking Factor and it s Vital Role in Surge Protection Device Coordination. Hans Slagter, DEHN + SOHNE

LPI SST Surge Filters

Technical Data Sheet Medium Current Power Surge Filters

OVERVOLTAGE PROTECTIVE DEVICE AND METHOD OF OVERVOLTAGE PROTECTION

Hazardous Area Protection

Ethernet Protection A Whole Solution Han Zou, ProTek Devices

Lightning Surge Response Improvement by Combinations of Varistors and Gas Discharge Tubes

Electromagnetic Compatibility ( EMC )

Lightning Surge Response Improvement by Combinations of Varistors and Gas -Discharge -Tubes

Remote telecom site protection

Introduction to Surge Protection

Lightning Current Equipotential Bonding SPDs

Overvoltage Protection

USER MANUAL MODEL 570-R8/570-R R8/580-R Base-T (CAT-5) Surge Protectors

Surge Protection for Low Voltage Power Systems

M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS

Surge & Filter Protection Addressing your industrial power quality needs.

LIGHTNING BOLTS Surge arrestors can prevent lightning from sparking a bad day.

Innovative Technology TVSS Products

ITU-T Recommendations and the Resistibility of Telecommunication Equipment

ETHERNET port surge testing Test levels and configurations

An Overview of Surge Protection for the Smart Grid IEEE PES/SPDC WG Matt Wakeham, Chair

LPI SG + SST Spark Gap Surge Filter

The following standards are the basis of design, manufacture, and test of SPD equipment: Guide for Surge Voltages in Low-Voltage AC Power Circuits

MICHIGAN DEPARTMENT OF TRANSPORTATION

HyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series

MICHIGAN DEPARTMENT OF TRANSPORTATION

Thermo Scientific ECAT

3 Design of the electrical installation protection system

KeyTek ECAT. Expert Computer-Aided Testing for pulsed EMI immunity. Technical Specifications

Reliability in Surge Protection. Surge Protection. AC & DC Power Photovoltaic Coaxial Telecom Gas Discharge Tubes.

ITU-T K.118. Requirements for lightning protection of fibre to the distribution point equipment SERIES K: PROTECTION AGAINST INTERFERENCE

The ABC s of Lightning TO BE SURE, USE DEHN

After the storm leaves the area, you pat yourself on the back for protecting your data and equipment. The worry is over. Or is it?

Single Source, Total EMC Test Solutions

METAL-OXIDE SURGE ARRESTER PROTECTION OF DISTRIBUTION SYSTEMS

USER MANUAL MODEL 570/ Base-T (CAT-5) Surge Protectors SALES OFFICE (301) TECHNICAL SUPPORT (301)

HOW TO VERIFY LIGHTNING PROTECTION EFFICIENCY FOR ELECTRICAL SYSTEMS? TESTING PROCEDURES AND PRACTICAL APPLICATIONS

INTRODUCTION LIGHTNING MAGNITUDE AND FREQUENCY

SOUTH CAROLINA ELECTRIC COOPERATIVES SECONDARY TYPE 1 SURGE PROTECTIVE DEVICE SPECIFICATIONS Updated/Revised: October 6, 2014

A.C. VOLTAGE SURGE SUPPRESSOR SPECIFICATIONS (SOLID-STATE TYPE)

GENERAL UL th EDITION DESIGN-BUILD SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-3: SURGE PROTECTOR PERFORMANCE AND EVALUATION CRITERIA

Surge Protection Devices Type 1+2

Metal Oxide Varistor (MOV) Data Sheet

Overvoltage Protection

Session Thirteen: The need to ensure energy co-ordination of surge arresters in terms of SANS 10142:2009 section L.1.3.3

Maximize Your Uptime: Reducing Risk of Power Supply Failure

AN4275 Application note

AC Surge Protection Devices

PRACTICAL EXAMPLES OF OVERVOLTAGE PROTECTION

Metal Oxide Varistors (MOV) Data Sheet

US Catalog March Surge protective devices (SPDs) UL range

ETITEC - Lightning and Surge Arresters

A Development of Electro-Static Discharge Evaluation Circuit for Varistors and Zener Diodes

CPS block & CPS nano UL rd Ed. Surge protective devices (SPD)

CIRCUIT BREAKER TYPE DISCONNECTOR for OVERVOLTAGE PROTECTOR

First Principles of a Gas Discharge Tube (GDT) Primary Protector

BS th Edition wiring regulations Furse overview

White Paper October 2009

Telcordia GR-1089-CORE Issue 4 Topics Primary Protection

Application Note: High Power Semiconductor Crowbar Protector for AC Power Line Applications

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14

Application Note. Table 1. Test requirements by equipment type

Metal Oxide Varistor (MOV) Data Sheet

Handling Transient Threats in RS-485 Systems

Transcription:

Surge Current Capacities Introduction This document attempts to clarify the surge ratings of several Novaris power line and signal line surge protectors. Surge rating (also referred to as maximum surge current capacity, surge withstand, maximum surge handling, etc.) is a specification that is often misunderstood. Most people would think that a surge protector rated at 200kA should be able to survive a 200kA surge. This sounds logical enough, however it is actually entirely unreasonable. The largest surge current specified in both the British Standard BS6651 and the American Standard IEEE C62.41 is only 10kA. This figure has been reached through years of research and field measurements. The largest surge current specified in any lightning protection standard anywhere in the world is only 70kA (Australian Standard AS1768). So, if lightning protection standards committees from around the world agree that a surge greater than 70kA will never occur, why are some surge protectors rated at 200kA? This is a straightforward question, and deserves an equally straightforward answer. The answer is that surge protectors rated at 200kA are not designed to withstand 200kA surges, but instead are designed withstand many surges of less than 70kA. To understand this concept an understanding of the surge protection components must first be gained. Metal Oxide Varistors The most common surge protection component is the metal oxide varistor (MOV). It is used in almost all power line surge protectors and also in many signal line protectors. They have proved to be a highly reliable and effective surge protection component over many years now. Each surge that a MOV experiences causes a small amount of degradation. The amount of degradation depends on the diameter of the MOV and the magnitude of the surge. For example a 40mm strap MOV can withstand at least 1 : - 1 x 40kA surge - 10 x 15kA surges - 100 x 5kA surges 1 Information from the EPCOS SIOV Metal Oxide Varistor Data Book 2001 Date: 15.01.03 Page: 1 of 9

- 1,000 x 2kA surges - 10,000 x 500A surges - 100,000 x 200A surges Therefore, in order to achieve a long working life out of a MOV-based surge protector it should have a surge rating much greater than the magnitude of the surges it is expected to experience. Over many years Novaris have been formulating, testing and revising a recommended MOV surge rating guide to assist customers in selecting a surge rating that will achieve a long working life for their applications. It is shown in Figure 1 below. The guide takes into account the area that the surge protector is to be installed in (Categories defined according to AS1768), the average number of thunder days experienced at the site per year, and whether the power cables coming into the site are underground or overhead. Novaris customers have found this guide to be very useful and have reported longer working lives from their surge protectors than they had previously experienced. Area: Area 1 Area 2 Area 3 Area 4 Category: Cat A Cat B Cat C Cat C High Thunder days <30 30 <30 30 Underground 8kA 16kA 40kA 80kA 120kA 160kA Overhead 8kA 16kA 80kA 120kA 160kA 200kA Figure 1 Novaris Recommended MOV Surge Ratings Gas Discharge Tubes Gas discharge tubes (GDTs) are widely used in signal line protectors. They are typically rated at 5kA, 10kA or 20kA. They suffer far less degradation due to surges than MOVs and subsequently can withstand many thousands of surges below or up to their surge rating. Silicon Avalanche Diodes Silicon avalanche diodes (SADs) are also widely used in signal line protectors. Typically they have very low surge ratings about 100A. Therefore, they are generally used in the third stage of protection so that they do not experience large surges. SADs suffer very little degradation due to surges and subsequently can withstand many thousands of surges below their surge rating. Date: 15.01.03 Page: 2 of 9

Specified Surge Ratings As with all surge protection manufacturers, Novaris determine the surge rating of a surge protector by adding the surge ratings of the individual components as specified by the manufacturer of the components. However, something that does vary from manufacturer to manufacturer is the way in which this is done. Surge Rating Per Mode or Surge Rating Per Two Conductors A mode is any combination of two conductors. For example, in a single-phase power system there are three modes: L-N, L-E & N-E. The surge rating of a particular mode may be defined as the sum of the surge ratings of the components that conduct when a surge is applied to that mode. This is Novaris s preferred method of specifying surge ratings. Surge Rating Per Phase Surge rating per phase may be defined as the sum of the surge ratings of the components connected to a particular phase. For example, in a three-phase power line protector the surge rating for Phase 3 would be equal to the sum of the surge ratings of all of the components connected from Phase 3 to Neutral and Phase 3 to Earth. Total Surge Rating to Earth The total surge rating to earth may be defined as the sum of the surge ratings of all of the components connected to earth. For example, in a three-phase power line protector the total surge rating to earth would be equal to the sum of the surge ratings of all of the components connected from Phase 1 to Earth, Phase 2 to Earth, Phase 3 to Earth and Neutral to Earth. Total Surge Rating The total surge rating may be defined as the sum of the surge ratings of all of the components within the surge protector. Date: 15.01.03 Page: 3 of 9

Novaris Surge Tests Laboratory Novaris have a dedicated surge test laboratory, one of the best equipped in the Asia-Pacific region. It has four surge generators, all compliant with IEC 61000-4-5:1995 Electromagnetic compatibility (EMC), Part 4: Testing and measurement techniques, Section 5: Surge immunity test. This Standard defines tolerances for the magnitudes and waveshapes of the various standard surge test waveforms. 1. 20kA 8/20µs, 10kV 1.2/50µs combination wave surge generator 2. 3kA 8/20µs, 6kV 1.2/50µs combination wave surge generator 3. 6kV 0.5µs 100kHz ring wave surge generator 4. 5kV 10/700µs 100kHz ring wave surge generator Together these surge generators are capable of producing all of the relevant standard surge test waveforms with the sole exception of the 70kA 8/20µs waveform specified in AS1768 for Category C High Exposure locations. Date: 15.01.03 Page: 4 of 9

Novaris Surge Tests Surge Protectors with Surge Ratings 20kA All Novaris surge protectors with surge ratings 20kA are tested to their surge rating in Novaris s surge test laboratory. Surge Protectors with Surge Ratings > 20kA All Novaris surge protectors with surge ratings exceeding 20kA are based on one particular component: 40mm strap MOVs. These components have a manufacturer s single shot 8/20µs surge rating of 40kA. The reason why Novaris base their surge protectors on 40kA MOVs (and not smaller MOVs like many manufacturers) is due to the problems associated with current sharing between MOVs. It is widely documented that MOVs connected in parallel do not share current perfectly evenly. 40kA MOVs can withstand multiple Category C surges 2 individually. This means that Novaris surge protectors (with ratings 40kA) do not rely on current sharing whatsoever. It is this fact that makes Novaris surge protectors extremely reliable. In order to complete the full range of surge waveform tests on their surge protectors Novaris had 70kA 8/20µs surge tests performed independently by EJ Bondarenko & Associates at the Telstra Research Laboratories High Voltage Laboratory. The 40kA MOVs were tested both individually and in a parallel arrangement as they are used in some Novaris surge protectors. Also a 160kA rated MultiMOV surge diverter was tested. The following is a summary of some of the findings of these tests: 1. The component manufacturer s 40kA rating is extremely conservative. One 40kA MOV withstood ten 40kA surges without failure. 2. Four 40kA MOVs in parallel withstood seventeen 70kA surges before the first MOV failed. The final MOV failed after a total of thirty 70kA surges. 3. Four MOVs in parallel shared current within 10% of each other. Summary All Novaris surge protectors are tested to their surge rating, or up to 20kA if their surge rating exceeds this. All Novaris surge protectors with surge ratings exceeding 20kA are based on 40kA MOVs, which have been tested to 70kA and have proved to be highly effective. Novaris s surge testing process is very thorough, ensuring that Novaris surge protectors will perform as specified in the real world. 2 10kA for BS6651 and IEEE C62.41. 20kA for AS1768 Date: 15.01.03 Page: 5 of 9