Fundamentals of Thyristor Overvoltage Circuit Protection

Similar documents
Application Note. Table 1. Test requirements by equipment type

Ethernet Protection A Whole Solution Han Zou, ProTek Devices

SiBar Thyristor Surge Protectors

Application Note. CPE Industry Specifications: UL60950 and TIA-968-A

Revised Standards Provide Design Options for Primary and Secondary Protection TELECOM PROTECTION WHITE PAPER

White Paper. AC Surge Protection. Evaluation of Series Element Surge Protective Device for Protection of Electronic Equipment and Systems

ITU-T Recommendations and the Resistibility of Telecommunication Equipment

DATA SHEET THYRISTOR SURGE SUPPRESSORS MODEMS/LINE CARD PXXXXLX series

Application Note: High Power Semiconductor Crowbar Protector for AC Power Line Applications

Handling Transient Threats in RS-485 Systems

First Principles of a Gas Discharge Tube (GDT) Primary Protector

Circuit Protection Application Note TBU Electronic Current Limiter GR-1089 Port Type 2 and 4 Ethernet Protection

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

Product Overview 2Pro AC Devices Provide Overcurrent/Overvoltage/ Overtemperature Protection for AC Industrial and Appliance Applications

APPLICATION NOTE. Prepared by: Alfredo Ochoa, Alex Lara, and Gabriel Gonzalez Thyristor Applications Engineers

White Paper Surge Current Characteristics: 570 Hybrid Surge Protective Device

SAMPLE. MOVs are sometimes referred

Systems which use a conventional POTS subscriber line to dial a compatible system and transfer digital data.

TELECOM EQUIPMENT PROTECTION: TRISIL

UL Recognised Fusible Resistors

glossary GE Digital Energy Power Quality Surge Protective Devices (SPDs)

RS-485 Port Protection Evaluation Board 4

AC Line Voltage Transients and Their Suppression

TVS Voltage Characteristics for an Electrostatic Discharge Pulse

CONNECT AND PROTECT. nvent ERICO Critec SRF N-Series. Surge Reduction Filters

Data Sheet. Surge protection devices - A technical overview

MDSP-Series 90kA, 150kA, 300kA Modular Distribution Surge Protector Type 2 Class II Surge Arrester

Semiconductor Protection Devices

A.C. VOLTAGE SURGE SUPPRESSOR SPECIFICATIONS (SOLID-STATE TYPE)

TBU-KE Series - TBU High Speed Protectors

GLOSSARY OF TERMS. Surge and Lightning Protection ERICO Inc.

Bourns Electronic Current Limiters

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-3: SURGE PROTECTOR PERFORMANCE AND EVALUATION CRITERIA

Data Book. TECCOR ELECTRONICS 1800 Hurd Drive Irving, Texas United States of America

AN579 Application note

ENGR. MARITES R. PANGILINAN, P.E.E.

TBU-DT Series - TBU High-Speed Protectors

The ABC s of Lightning TO BE SURE, USE DEHN

Features. Samples. Units Continous: Steady State Applied Voltage: DC Voltage Range (VM(DC)) 150 to 970 V AC Voltage Range (V M(AC)RMS

METAL OXIDE VARISTORS

LIGHTNING AND SURGE PROTECTION

The following standards are the basis of design, manufacture, and test of SPD equipment: Guide for Surge Voltages in Low-Voltage AC Power Circuits

AN4275 Application note

Electromagnetic Compatibility ( EMC )

Technical Data Sheet Medium Current Power Surge Filters

Metal Oxide Varistor:TVB Series

Contact protection relay

AC Line Voltage Transients and Their Suppression

Latch-Up. Parasitic Bipolar Transistors

Description. Features. Continuous RA8 Series RA16 Series RA22 Series Units. ) 4 to to to 275 V DC Voltage Range (V M(DC)

MONITORING ABSTRACT KEYWORDS. TRANSFORMERS MAGAZINE Special Edition: Bushings, 2017

National Standard of The People s Republic of China

Standards Update Notice (SUN) Issued: August 11, 2017

CPC7591BB. Line Card Access Switch INTEGRATED CIRCUITS DIVISION

Zinc Oxide Varistor Series ( Standard Surge ) :

Overvoltage Protection

Surge Protection for Low Voltage Power Systems

MSP Reliability White Paper Bourns, Inc. Hans-Wolfgang Oertel Vice President of Technology

RClamp TM 0504M RailClamp Low Capacitance TVS Diode Array PRELIMINARY Features

Telcordia GR-1089-CORE Issue 4 Topics Primary Protection

Understanding Solid-state relays

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

CotoMOS. Technical & Applications Information. page 75

MICHIGAN DEPARTMENT OF TRANSPORTATION

TBU-DT Series - TBU High-Speed Protectors

AC Surge Protection Devices

BA/BB Varistor Series

/60 ETITEC A 15/ /60 ETITEC A 15/440 Al/Fe connection*

ETHERNET port surge testing Test levels and configurations

Redundant Bus Protection Using High-Impedance Differential Relays. Josh LaBlanc

2 Principle of lightning protection

CPC1964BX6. Rapid Turn-On AC Power Switch INTEGRATED CIRCUITS DIVISION. Description. Features. Approvals. Ordering Information.

Mitigation of Voltage Swells I

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

LPI SST Surge Filters

VI-IAM /MI-IAM Input Attenuator Module

US Catalog March Surge protective devices (SPDs) UL range

TDX Series. Transient Discriminating TM TVSS

LPI SG + SST Spark Gap Surge Filter

YOU NEED A WHOLE- HOUSE PROTECTION SYSTEM

SMP75. Trisil for telecom equipment protection. Features. Description. Applications. Benefits

PXC05-Dual Output Series: DC/DC Converter Module 9 to 75 Vdc input, 3.3 to 15 Vdc Dual Outputs, 5W

SP pF 8kV DFN Plastic Unidirectional Discrete TVS

Surge Protector. Esma Khatun

Overvoltage Protection Devices

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

Bourns TBU. High-Speed Protectors Short Form Brochure

White Paper Transient Surges and Suppressor Technologies

Application Note TAN MTL Surge Technologies. Lightning surge protection for electronic equipment - a practical guide.

MICRO BURN IN PRODUCTS LISTED IN MODEL NUMBER ORDER FOLLOWED BY A BRIEF DESCRIPTION

Suppressing Transients: A New Approach

SP A Discrete Bidirectional TVS Diode

TDS Transient Discriminating Surge Diverters

www. ElectricalPartManuals. com

LPI SG + SS480 Spark Gap Surge Filters

TECH NOTE #: CPS-1 SUMMARY OF APPLICABLE UL AND IEEE STANDARDS

SPM Series. Plug-in Surge Protection

SMDD3K Series HIGH POWERED DSIP TVS ARRAY DESCRIPTION DSIP PACKAGE APPLICATIONS FEATURES MECHANICAL CHARACTERISTICS PIN CONFIGURATIONS

HF81 X Capacitor Bleeder

SPM Series Plug-in Surge Protection

Transcription:

Fundamentals of Thyristor Overvoltage Circuit Protection Thyristor Surge Protection Technology The Problem of Overvoltages Electronic components have been designed to function properly when used within their specified current and voltage ratings. When these ratings are exceeded during operation, the component may sustain permanent damage and the equipment may cease to operate. low-impedance state in response to an overvoltage surge. In telecommunications applications, the major sources of overvoltage conditions are lightning, and interaction with the AC power system usually in the form of power cross or power induction surges. Lightning surges may directly strike a telecom line, or may induce a potential rise when they strike a nearby ground. Power cross surges occur when fallen AC power lines directly contact a telecom line. Power induction surges occur when AC power lines induce voltages in adjacent telecom lines, or when a nearby fault to ground subjects the equipment to a rise in system ground potential. All these threats can be addressed by providing coordinated overvoltage and overcurrent protection. In response to overcurrent conditions, polymeric PTC (positive temperature coefficient) resettable fuses installed in series with these components have proven to be a reliable method of interrupting the current flow by switching from a low- to a high-impedance state. To protect from overvoltage conditions, solid-state thyristors may be installed in parallel with these components to switch rapidly from a high- to a Figure 1: Typical Overcurrent and Overvoltage Protection Location Overcurrent protection Overvoltage protection Vulnerable devices to be protected Raychem Circuit Protection Devices Fundamentals of Circuit Protection 9

Overvoltage Protection Overvoltage protection devices are connected in parallel with a load to limit the amount of voltage that can appear across the input to a telecommunications circuit, as shown in Figure 1. The overvoltage device appears as a very high impedance (virtually an open circuit) under normal operating conditions. When an overvoltage event occurs, the overvoltage device changes its impedance to divert current around the protected circuit to ground. Overvoltage devices are designed to protect not only telecommunications circuits but also maintenance personnel and subscribers. In addition, they must: Not interfere with the normal operation of the telephone service. Provide maintenance-free operation. Reduce long-term cost of the installation by minimizing maintenance time and system downtime. Allow the designer to easily meet industry standards. Overvoltage Protection Devices There are two categories of overvoltage protection devices: clamping and foldback (or crowbar ) devices. A clamping device, such as a metal-oxide varistor or diode, allows voltages up to the designed clamping level to pass through to the load during operation. A foldback device, such as a gas discharge tube or a thyristor surge protector, reduces the circuit voltage to a low level in response to a surge that exceeds its breakover voltage. Foldback devices have a current-voltage (I-V) curve similar to that shown in Figure 6. A foldback device is normally in a high-resistance state for voltages below the breakover voltage. In this state very little current flows through the device. When the voltage exceeds the breakovervoltage, the device folds back or goes into a low-impedance state, allowing the device to conduct large currents away from sensitive telecom electronics. The device will continue to remain in this low-impedance state until the current through the device is decreased below its holding current. A foldback device has an advantage over a clamping device because in the foldback state very little voltage appears across the load while it conducts harmful Table 1. Agency standards for telecommunications equipment Requirement Application Overvoltage protector Market segment* Region* Bellcore GR-974 Line protectors for telco equipment Primary Primary U.S. Bellcore GR-1089 Telco-owned network equipment Secondary Network U.S. FCC CFR47, Part 68 Subscriber-owned equipment Secondary CPE U.S. UL497 Line primary protectors for Primary Primary U.S. subscriber-owned equipment UL497A Line secondary protectors for Secondary CPE U.S. subscriber-owned equipment UL497B Protectors for data comm and Secondary CPE U.S. fire alarm circuits UL1459 Subscriber-owned equipment Secondary CPE U.S. connected to telco lines UL1950, 3rd Ed. Information technology equipment Secondary CPE North America ITU K.11 Principles of protection Primary/ All ROW Secondary ITU K.0 Telecommunications switching Secondary Network ROW equipment ITU K.1 Subscriber terminal equipment Secondary CPE ROW ITU K.8 Semiconductor arrestor assemblies Primary Primary ROW for telco installations *CPE = Customer Premise Equipment; ROW = Rest of World 30 Fundamentals of Circuit Protection Raychem Circuit Protection Devices

surges away from the load. Conversely, a clamping device remains at the clamping voltage during a surge. The power dissipated in the foldback device is therefore much lower than in a clamping device, allowing a much smaller device to be used to conduct the same amount of surge current. Agency Requirements for Telecom Applications A large number of agency requirements are imposed upon telecommunications circuits to simulate lightning, power cross, and power induction. The most common specifications come from Bellcore, FCC, UL, and ITU as shown in Table 1. These agency specifications have recognized that hazard level (for example, lightning peak current or short-circuit current) and hazard frequency are typically inversely related. Therefore, it is appropriate that telecommunications equipment should continue to operate after more frequently occuring lower-level hazards, whereas safety should be the primary requirement after infrequent high-energy hazards. As a reflection of this principle, the specifications include tests for which the pass-fail criterion is that the equipment must continue to be operational. Examples of these types of tests include the FCC Part 68 Type B surge, the ITU Criteria A requirements, and the Bellcore GR-1089 Level 1 requirements. Other more severe specification tests have pass-fail criteria that merely require the equipment not to create a fire hazard or a safety hazard or impair network operation (though it would be desirable that the equipment continue to function). Examples of these types of tests include the FCC Part 68 Type A surge, the ITU Criteria B requirements, and the Bellcore GR-1089 Level requirements. Lightning waveforms are defined by their peak open-circuit voltage, their peak short-circuit current (I PP ), and the open-circuit and short-circuit waveforms. The waveforms are specified by the rise time and the decay time (t d ). The rise time is defined as the time from 10 percent to 90 percent of the peak value (t r ) times a constant 1.5. The decay time is defined as the time from the beginning of the wave to 50 percent of the peak value after the peak has occurred. For example a 10/1000 100 A wave has a peak current of 100 A, a 10 µs rise time (8 µs from 10 A to 90 A), and a decay time to 50 A of 1000 µs. Figure shows a typical lightning overcurrent waveform. Current 90% I PP 50% I PP 10% I PP Figure : Typical Overcurrent Lightning Waveform Peak current I PP τ r τ d The integration of voltage, current, and time defines the energy transferred to the protective device higher energy surges require larger, more rugged devices to meet the requirements. A comparison of various lightning surge requirements by specification appears in Table. In response to a transient surge, a thyristor folds back to provide a low-impedance path to ground. The circuit must contain enough impedance to limit the surge current below the peak pulse current (I PP ) rating of the thyristor. In addition, the overcurrent protector should be specified so that it does not operate during a lightning pulse. For power induction and power contact, the thyristor will remain in a high-impedance state as long as the fault voltage is below the device breakover voltage. If the fault voltage exceeds the breakover voltage, the thyristor will conduct a large surge current to shunt the harmful energy away from the load. The overcurrent Time in µs Raychem Circuit Protection Devices Fundamentals of Circuit Protection 31

Table. Comparison of various agency lightning surge requirements by specification Agency standard Open-circuit Peak Short-circuit Peak voltage voltage current current waveshape (kv) waveshape (A) Bellcore 1089 Surge 1 10/1000 µs 0.6 10/1000 µs 100 Surge 10/360 µs 1.0 10/360 µs 100 Surge 3 10/1000 µs 1.0 10/1000 µs 100 Surge 4 /10 µs.5 /10 µs 500 Surge 5 10/360 µs 1.0 10/360 µs 5 FCC Part 68 Type A 10/160 µs 1.5 10/160 µs 00 10/560 µs 0.8 10/560 µs 100 FCC Part 68 Type B 9/70 µs 1.0 5/30 µs 5 9/70 µs 1.5 5/30 µs 37.5 ITU K.17 10/700 µs 1.5 5/310 µs 38 ITU K.0 10/700 µs 1.0 5/310 µs 5/100* VDE 0433 10/700 µs.0 5/00 µs 50 RLM 88, CNET 0.5/700 µs 1.5 0./310 µs 38 Notes: *For ITU K.0, secondary protector must be able to accommodate 5 A lightning, primary protector must accommodate 100 A. protector needs to be designed to prevent the resulting current from damaging the equipment or causing a fire. To provide fully resettable protection, the overcurrent protector must also protect the thyristor from damage under these conditions. Thus the continuing and safe operation of the equipment depends on careful coordination between the overvoltage and overcurrent protectors under a variety of fault levels and fault durations. Device Construction and Operation To understand how SiBar devices assist telecom equipment in meeting industry specifications, the four symmetrical layers of a thyristor chip may be drawn as shown in Figure 3. Reviewing the left hand side of the symmetrical chip, the layout can be simplified to depict two s and a P-type resistor as shown in Figures 4 and 5. During normal operation, voltage is applied across the two terminals. As voltage increases from anode to cathode, avalanche breakdown in the PNP "P" base Figure 3: Basic Diagram of Thyristor Chip "N" emitter "N" emitter "P" base Symmetry line "P" shorts Figure 4: Cross Section of One Side of a Thyristor Chip PNP P resistor NPN "N" emitter "P" base 3 Fundamentals of Circuit Protection Raychem Circuit Protection Devices

allows current to begin to flow. The increasing avalanche current flows from the anode through the PNP and then through the P resistor to the cathode. Voltage across the P resistor as a result of I biases on the NPN. When the NPN is biased on, the PNP is rapidly switched on, causing the device voltage to fold back. The device is latched on due to the collector current of the PNP driving the base of the NPN, and the collector current of NPN driving the base of the PNP. Figure 5: Equivalent Circuit of a Thyristor Chip PNP I P resistor Anode Cathode NPN SiBar devices are N-type devices and have an I-V characteristic as shown in Figure 6. Terminology for specific points of the I-V curve are defined as follows: Figure 6: Characteristic Curve and Terminology for a SiBar Device I PP I I PP (nonrepetitive peak pulse current): The rated maximum value of peak pulse current of specified amplitude and waveshape that may be applied without damaging the device. I T I H I BO I T (on-state current): The current through the device during the on-state condition. I DM V I H (hold current): The minimum current required to maintain the device in the on-state. V T V DM V BO I BO (breakover current): The instantaneous current flowing at the breakover voltage, VBO. I DM (off-state current): The maximum DC value of the current that results from the application of the maximum off-state voltage, V DM. V BO (breakover voltage): The maximum voltage across the device in the breakdown region, measured under specified voltage rate of rise and current rate of rise. V DM (maximum off-state voltage): The maximum DC voltage that may be applied while keeping the device in the off-state. V T (on-state voltage): The voltage across the device in the on-state condition at a specified current, I T. Device Design Parameters Off-state current (I DM ) The off-state current is the amount of current that flows through the device during the off-state condition. This current should be as low as possible to minimize loss in the circuit. The off-state current is measured at V DM, the maximum off-state voltage. Raychem Circuit Protection Devices Fundamentals of Circuit Protection 33

Hold current (I H ) The hold current is the current flowing through the device, below which the device resets from the on state to the off state. The designer must confirm that the supply current in the circuit would drop below the hold current of the thyristor after a transient event, thus ensuring that the device will reset. Maximum off-state voltage (V DM ) rating The V DM rating defines the maximum voltage that may be applied while keeping the device in an open-circuit condition. To minimize nuisance operation, the designer must select a device that has a V DM greater than the peak ringing voltage plus the DC supply voltage. Breakover voltage (V BO ) The breakover voltage, V BO, is the voltage at which the device folds back. The breakover voltage is the maximum voltage that will appear across the device and the circuit that it is protecting. The designer should ensure that the circuit can withstand voltages up to the maximum V BO level without damage. On-state voltage (V T ) The on-state voltage is the voltage across the device when it has folded back and is conducting. While not directly a critical parameter in selecting the device, V T may be used to calculate the power dissipated in the device when it is in the on state. The higher the V T for a given current, the higher the power dissipated by the device. Peak pulse current (I pp ) The peak pulse current rating is dependent upon the transientcurrent waveshape. The circuit must be designed to ensure that the surge current expected during operation is within the device ratings. Maximum current rate of rise (di/dt) The di/dt rating is the maximum rate of current rise the device can withstand without being damaged. The damage of a device under di/dt occurs when the concentration of surge current is applied on a localized area of the thyristor chip. Maximum voltage rate of rise (dv/dt) The dv/dt rating of the device is the maximum rate of voltage rise the device can withstand without turning on. For voltage rates of rise greater than this value, the device could potentially fold back without exceeding the breakover voltage. Capacitance (C O ) When inserted into a circuit, the device capacitance loads the protected circuit. Like all thyristors, the measured capacitance of a SiBar device depends on applied voltage and frequency. Peak on-state surge current (I TSM ) SiBar devices are typically used in coordination with overcurrent protection devices like the PolySwitch TR series. To design the appropriate protection circuit, the designer needs to know the performance of the overvoltage device when it is subjected to a power cross or power induction surge. Testing and modeling of the SiBar devices have been performed to determine the maximum allowable current for various time durations, and the results are typically shown as I TSM vs. time. For resettable protection designs, the I TSM curve of the thyristor should lie above the time-to-trip curve of the resettable overcurrent protection device. Device Reliability Testing The following reliability tests are conducted on SiBar devices to ensure long-term performance: Autoclave (PTH) This test measures device robustness against moisture penetration and the resultant effects of galvanic corrosion. High-Temperature Storage Life (HTSL) This test accelerates failure mechanisms that are thermally activated through the application of extreme temperatures. Temperature Cycling (TC) This test evaluates the device s ability to withstand both exposure to and transitions between extreme temperatures. The test also exposes excessive thermal expansion coefficient mismatch between materials. High-Humidity, High-Temperature Reverse Bias (H3TRB) This test measures the moisture withstand of plastic encapsulated devices under high temperature and voltage bias. High-Temperature Reverse Bias (HTRB) This test measures the robustness of devices against simultaneous high temperature and voltage stress. 34 Fundamentals of Circuit Protection Raychem Circuit Protection Devices

Agency Approvals Raychem s SiBar devices have been tested and have gained UL Recognition per UL497B. Design Considerations When selecting devices for a particular application be sure to ask the following questions: 1. What is the maximum required off-state voltage? The maximum off-state voltage rating of the device (V DM ) must be greater than the maximum system continuous operating voltage, defined as the sum of the peak ringer (AC) voltage plus the DC battery voltage.. What is the required protection level? The maximum breakover voltage of the protection device should be lower than the minimum failure level of all system components to be protected. 3. What peak pulse current is required? What agency approvals are required? SiBar devices are designed to assist equipment in meeting the requirements of various regulations. Choose the appropriate SiBar TVB series by matching the SiBar peak pulse current ratings to the regulatory specifications. Alternatively, consider the resistance of the overcurrent protection device and, if necessary, add additional resistance to reduce the specification pulse current to within the chosen device rating. 4. What hold current is required? The hold current defines when the overvoltage device should reset (switch from low impedance to high impedance) to return the system back to normal. The device I H must be greater than the source current of the system or else the SiBar device will continue to stay in the lowimpedance state. 5. Has proper coordination between the overcurrent and overvoltage devices been achieved? Compare the I TSM curve of the thyristor to the time-to-trip curve of the overcurrent protection device. Ensure that the overcurrent device trips before the thyristor device fails under relevant fault conditions. Raychem Circuit Protection Devices Fundamentals of Circuit Protection 35