User Manual D2330 Test Set/Service Tool for D243X-series, EN54-certified, 24VDC Switched-Mode Power Supply Units

Similar documents
Installation Manual for D244X Series 24-volt Power Supplies

Installation Manual for D155X Series of 12V Switched Mode Power Supply for Access Control

Installation Manual for D24XX Series of 24V Switched Mode Power Supplies

METERING/DISPLAY MANUAL

Trend-1 Vibration Data Logger. User Manual

Installation Manual for D1800 Series High Power PoE Midspan Power Supply

CF3000 Dealer Diagnostic Tool Instruction Manual

Mini Digital Multimeter

BLUETOOTH AMPLIFIER KIT

Installation and Operation Manual for the D5000 Audio Verification Unit

Safety. 2. Configuration - Operation 2.1 RTD Selection 2.2 Driver Test Header. 3. Diagnostics 3.1 ph Input 3.2 Temperature Input

DLRO 200 High Current, Low Resistance Ohmmeter

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Chassis Power Supplies

Instruction It can display battery voltage, discharge current, time, battery

MC1000 Multi-Function Calibrator

User's Guide. Digital Multimeter. Model MN42

EFE300 / EFE400 EFE300M / EFE400M

Model HM-535 Power Supply Installation and Service Instructions

REEKBOX.com Thank you for choosing Shenzhen Sundeu Technology Please read the user manual carefully before using the product for any purpose

Really Performs! Here is a Hand-Held Data Logger that Royalton Rd. Cleveland, OH USA Tel: (440) Fax: (440)

Before Installing a PC software upgrade use Control Panel/Programs/Uninstall to uninstall the existing MULTiLOG2 software.

Mini Digital Multimeter

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Operating Instructions

T0046 PROFESSIONAL LAN CABLE TESTER USER GUIDE

Operating Instructions

CALOG CALOG - LC DISPLAY. Loadcell Display. English Users Manual. Rev. 1.10

Modbus communication module for TCX2: AEX-MOD

EFE300 / EFE400 EFE300M / EFE400M

2 in1 LAN Tester & Multimeter. Model: PCE-LT 1

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

Jandel RM3 operating instructions

Installation and Operating Handbook. ICLH Combiner ISLH Splitter

LC-110/H. Reference Manual

Instruction Manual Wally Box II Digital - Pneumatic - Calibrator IM DE (WIKA)

ph/orp Meter SD Card real-time Datalogger

Installation / Operator / Service Manual. Bench Scales Revision 6 07/ by Fairbanks Scales Inc. All rights reserved

ProHD1 Portable Audio HardDisk Recorder. Manual 1.40 ( )

INSTRUCTION MANUAL C WA2 WELD ANALYZER

DATRAN XL4 PLUS RTU Quick Start Guide

TITAN S8. Portable Data Acquisition Logger. Product User Guide

HygroPalm 0. Portable Humidity Temperature Indicator. Instruction Manual

BEP 600-DCSM DC SYSTEMS MONITOR. Installation and Operating Instructions. INST-600-DCSM-V1 Page 1

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

DSTCAL Software User Manual 09/16/09 WD1037 Rev E Revised 09/09/14

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR

BF ENTRON LTD. Monitoring equipment. Weld Analyser WA2

Mini Digital Multimeter

Thermocouple Calibrator Type DP6

EnCell Battery Cell Monitor

CONGRATULATIONS ON THE PURCHASE OF YOUR THUNDER BATTERY MONITOR

installation quick guide integrated access control & environmental monitoring

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

Mini Digital Multimeter Model MN15. User's Guide

SBS-S SERIES DC LOAD BANK USER MANUAL

SensorWATCH Basic RH - Wireless Setup Users Help Guide Part Number: A Revision: 1.1.0

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

Sigma XT Ancillary Board (K588)

THERMOCOUPLE CALIBRATOR TYPE DP6

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

PIECAL 510B/511B RTD Simulator Operating Instructions

SY021 Portable Load/Force Meter User instructions

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

SPICE RACK DIMMER OPERATING MANUAL

DX4085 Z-Meter Tester

2 Product Overview. 5 User Interface. 14 Logging Data. 17 Viewing Data. 19 Managing Data. 24 Device Settings. 26 Specifications.

Hand-held thermometer Model CTH7000

THOR Battery Backed DC Power Supply Reference Manual

1. Installation. 2. Configuration - Operation. 3. Specifications. Safety

SUNRISE MEDICAL EDUCATION DEPARTMENT INFO. VR2 Codes Display and Code description

Deviser Part No.: TC500-DL Deviser Instruments, Inc. All rights reserved.

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

RTD-500 Precision RTD Simulator. Operations Manual.

DPM Digital DC Power Meter with Data logging capability. User Manual

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

VIDI System Controller

AutoRanging Digital MultiMeter

Hand-held thermometer Model CTH7000

User Guide True RMS Multimeter Extech EX205T

is then retained absolutely without interruption.

Board Of Education USB (#28850)

CII: Current Input, Isolated

Digital Thermostat for drum heaters Model HCL 5536

QUICK START USER GUIDE. Data Logger Model L452

Model R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com

MANUAL PCE-123

DL125 BLACK BOX. DATA LOGGING CONTROLLER ph/orp/temperature. Set Up / Operation Manual

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

GS400. Electronic Auto-Ranging DIN Panel Mounted Positioner

Contents 1 Warnings, Cautions, and Notes Description Features... 1

Model R5010. TRMS Digital Multimeter. Instruction Manual

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

NMEA Reader NMR183. User Guide

Power Supplies. Chapter The McGraw-Hill Companies, Inc. All rights reserved. Mike Meyers CompTIA A+ Guide to Managing and Troubleshooting PCs

HI HI HI HI HI HI HI

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Transcription:

User Manual D2330 Test Set/Service Tool for D243X-series, EN54-certified, 24VDC Switched-Mode Power Supply Units Dycon Power Solutions Ltd Unit A, Cwm Cynon Business Park Mountain Ash South Wales CF45 4ER United Kingdom Tel: +44(0)1443 471 900 www.dyconpower.com info@dyconpower.com

D2330 PSU Test Set / Service Tool Instructions Test Set / Service Tool Overview The Test Set / Service Tool is compatible with the Dycon range of EN54-4 24V power supplies: D2431-7 : 1.5A 24V power supply in medium box (2 x 7.5/8 Ah batteries) D2433-7 : 3.0A 24V power supply in medium box (2 x 7.5/8 Ah batteries) D2433-17 : 3.0A 24V power supply in large box (2 x 17.5/18 Ah batteries) D2435-17 : 5.0A 24V power supply in large box (2 x 17.5/18 Ah batteries) The D2330 allows the installer to monitor the performance of the power supply, system currents and voltages, the condition of the batteries and a log of PSU events and faults. It can also be used to calibrate and test power supplies. Test Set / Service Tool Description The D2330 is supplied in a removable tough rubber boot with hinged stand: A USB charging socket and RJ45 PSU connection socket are located at the top of the test set: Page 3 of 10

Programmer Keypad The programmer has a 15-key membrane keypad that is used to navigate through all the menus and enter and retrieve information. The up and down keys will scroll through the menus, the enter key is used to select menus and enter commands, the escape key allows the user to quit menus. The right arrow delete key is for future use and is not used in this version. Menu Navigation Up Key 4 X 20 Character Backlit LCD Display 1 2 3 Menu Navigation Down Key 4 5 6 Escape Key 7 8 9 0 Enter Key To Turn the Programmer On Press any of the left-hand column keys To Turn the Programmer Off Press the escape key repeatedly until Turn Off? is shown and press enter. If the unit is accidentally left on continuously, the programmer will automatically power down after 15 minutes of non-use. The test set will stay on continuously when the charging adapter is plugged-in and charging. Test Set / Service Tool Specifications SPECIFICATIONS Charging Charge Time Battery Battery Life Test Lead Display Communication interface USB Micro B, 5V, 450mA Maximum 2 hours to full charge Rechargeable LiPo battery, 3.7V nominal, 800mAH 2 days continuous operation I Metre FCC-68 (RJ45) to 5-way 2.5mm Molex KK receptacle Backlit 4 x 20 character LCS display, readable in direct sunlight 9600 baud, no parity, one stop bit, 5V logic, asynchronous serial Compatibility D2431-7, D2433-7, D2433-17, D2435-17 Accuracy Dimensions Weight +/- 2 Least significant digits. Actual measurements are derived from PSU 76.5mm x 127mm x 24mm without boot, 93mm x 155mm x 36mm with boot 140gm without boot, 310gm with boot Page 4 of 10

Warning Before using the test set / service tool, ensure that the AC power supply is switched off before removing the lid and plugging in the test cable. Programmer Menus Main Menu This menu selects the various functions of the test set. When the test set is first switched-on a screen with the software version is shown briefly in the lower right hand corner ( nnn on the illustration below). Pressing the up/down arrows steps through the functions. Pressing enter will select the menu of interest. Dycon D2430 Series Test Set 3DL test set nnn Measurements Information Commands Faults and Status Calibration Advanced Information Refer to manual For details Turn Off Measurements The measurement menu is used to select the various voltages, currents generated by the power supply and the battery impedance in ohms. The menu is accessed by pressing enter when Measurements prompt is shown: PSU Current Measurements Measurement Menu Output Currents Measure Amps Menu PSU Voltage Measurements Measurement Menu Battery Voltages Measure Volts Menu Battery Charging Current Measure Amps Menu Battery Impedance Output Voltages Measurement Menu Measure Volts Menu Charging Voltage Measure Volts Menu Page 5 of 10

PSU Current Measurements Pressing enter accesses the two current measurement menus by scrolling up and down using the arrows. Output Currents After pressing enter, the display will briefly show this message, whilst connecting. Followed by a typical display like this: Waiting for Data Output 1 = 1.20A Output 1 = 0.30A Outputs = 1.50A The bottom Outputs display shows the total current being used by outputs 1 and 2. This does not include the battery charging current. You can quit the Output Currents display by pressing the up arrow key. NOTE: There is a 300mA reserve of battery current, for example if a 5A PSU is already providing 5A, an extra 300mA (depending on the battery charge condition) can also be provided. In this case a total of 5.3A is being supplied. Battery Charging Current Selected by pressing enter, the following display is shown: The current shown is typical of a fully charged battery. Battery Charging Current 0.02A NOTE: If the battery current is varying wildly, this will probably be due to a discharged battery taking significant charging current and sharing the total current capacity with the output load, where the load is varying. PSU Voltage Measurements Three different menus are available in this measurement mode, these can accessed by pressing enter and using the scroll arrows. Battery Voltages When selected, the following display is Battery 1 = 13.34V Battery 1 = 13.65V Batteries = 26.99V shown: The battery voltages shown is typical of a fully charged set of batteries. Battery 1 and Battery 2 voltages are shown separately, the bottom Batteries voltage display is the sum of the individual battery voltages. NOTE: The individual battery voltages will seldom be identical, but should be balanced to at least 1V with respect to each other. Actual voltage values will depend on the charge state and temperature and are not necessarily related to the PSU charging voltage. Output Voltages When selected, this display is shown: Output 1 = 27.01V Output 2 = 27.03V Voltage at load will drop with current The output voltages will vary according to temperature and load current and will not necessarily be identical. NOTE: Voltage at the load will vary according to current causing voltage drop by the installation wiring. There will also be a small difference (a few tens of millivolts) caused by the PSUs small internal resistance needed for current monitoring. This is will be reflected by a small variations of the displayed voltage readings shown on the screens and is normal. Charging Voltage When selected, this display is shown: Charging = 27.00V The charging voltage is the internal PSU voltage used for battery charging when AC power is present and is dependent on temperature. NOTE: The charging voltage, battery voltage and output voltages will not necessarily be the same depending on mode and conditions. Page 6 of 10

Battery Impedance When selected the following display is shown: Battery Test Results Rbat = 0.095 Ohms Test Passed Limit 0.177 Ohms Rbat is the combined impedance (resistance) of the battery, battery leads, connectors and PSU charging path and must not exceed 0.177Ohms. If the test fails then a typical display might show the following: Battery Test Results Rbat = 0.186 Ohms Test Failed! Limit 0.177 Ohms If the test is attempted when the battery is not fitted or AC power is not present the following display is shown: Waiting For Data Fault Halted Test! Information The information menu is used to view the software version of the PSU firmware and the PSU type. Software Version Information Menu PSU Hardware Type Information Menu Software Version When selected the following display is shown. The two characters before and adjacent to the V indicate the version: Version Number EN54PSU08V PSU Hardware Type The display shows the PSU hardware type: Currently there are three types: 24V 1.5A: D2431-7 (2 x 7Ah batteries) 24V 3A: D2433-7 (2 x 7Ah batteries) 24V 3A D2433-17 (2 x 17Ah batteries) 24V 5A: D2435-17 ((2 x 17Ah batteries) PSU Hardware Type 24V 1.5A Commands The command menu remotely controls the switching of the two outputs in addition to the two local control inputs. OP1 Control Command Menu OP2 Control Command Menu OP1 Control The OP1 control screen is shown opposite. The first line displays the current OP1 On OP1 Local Control output status, either On or Off and is updated in real time. The second line 1=On 2=Off indicates if local or serial control is in operation in real time. When Serial 4=Local 5=Serial control is selected then numeric keys can be used to control the output. Number 1 switches the output on and 2 switches the output off. Numbers 4 and 5 select between serial and local control. Page 7 of 10

NOTE: When the control function is used to switch outputs, care has to be taken to return the PSU to the local control condition, otherwise the local control inputs on the PSU will be ignored. OP2 Control The OP2 control screen is shown opposite in serial mode with the output off: Please see above for operation. OP2 Off OP1 Serial Control 1=On 2=Off 4=Local 5=Serial Faults and Status This suite of functions display overall status of the power supply with informative, multiple data type screens for at a glance user information. Faults and a fault log is also displayed here with a user option of erasing the fault log so fresh history can be recorded. Output and PSU Status Fault & Status Menu Battery Charging and Current Share Status Fault & Status Menu Temp. Compensation Status Fault & Status Menu Fault Log Fault & Status Menu Erase Fault Log Fault & Status Menu Output and PSU Status A typical PSU and Output status is displayed in the adjacent screen: The PSU status is shown as follows: First line: Output switched status, either On or Off Second line: Output voltage Third line: Output current Fourth Line: AC On or Off, PSU fault status, OK or Fail O/P1 = On O/P2 = On 26.95V 26.90V 0.28A 0.79A AC On PSU OK NOTE: The Fail PSU status is displayed if any of the faults other than AC power failure are pending. Battery Charging and Current Share Status Battery = 0.65A 26.88V OP1&2=0.86A AC ON A typical battery status is displayed in the adjacent screen: Total =1.51A PSU OK B1=13.46V B2=13.42V The battery status is shown as follows: First line: Battery charging current and voltage Second line: Output 1 and 2 combined current and AC power status Third line: Total current provided by the PSU, i.e. battery and combined current outputs with PSU fault status Fourth Line: Battery 1 and 2 individual voltages NOTE: With a fully discharged battery the PSU will automatically any used capacity to charge the battery. For example, if 3 amps was taken from a D2435 5A PSU, then 2A would be diverted to charging the battery; in this Page 8 of 10

way, the PSU shares capacity with the outputs having the highest priority. A fully discharged battery will always be charged at a minimum of 300mA. If a D2433 is supplying all of its 3A capacity to its outputs, then the battery would be charged with a reserve of 300mA. In this case the total current would be 3.3A. Temperature Compensation Status This screen shows the Temperature compensation status: The temperature compensation data is displayed thus:- First line: Temperature, this is measured by a probe located between the two standby batteries Temperature = 31.0C Charging Voltage: Actual = 26.90V Ideal = 26.90V+/-0.07V Second and third line: Actual charging voltage being delivered to the battery, internally within the PSU. Fourth line: Ideal charging voltage, the test set has a mathematical model of the ideal theoretical voltage that should be used to charge the batteries at any given temperature. The actual measured voltage should be between +/- 70millivolts of the displayed actual voltage for maximum battery performance. NOTE: In this way the screen display can be used for checking that the battery is being charged correctly between specified limits. The sample screen shot is an actual reading taken off a real, randomly selected PSU, the actual and ideal voltages should track between these limits with temperature and will not necessarily be identical as shown. Fault Log The fault log records all fault events that have occurred since the log was cleared: Press down key to scroll through faults A list of 11 fault events are shown below: 1. SMPS Fault: Switched Mode Power Supply internal low voltage fault, supply is less than 20V. 2. PSU over 32V and PSU shutdown: Over-voltage fault and subsequent shutdown. 3. O/P1 fuse fault: Output 1 fuse fault. 4. O/P2 fuse fault: Output 2 fuse fault. 5. PSU under minimum battery charging voltage fault: Inability to correctly charge the battery because voltage is too low fault. 6. PSU not charging battery fault: Charging circuit malfunction fault. 7. Battery lead disconnected fault: One or both batteries are disconnected. 8. Battery high resistance fault: Battery impedance greater than 177millohm limit when being load tested. 9. Battery 1 under 11.5V fault: Battery 1 low voltage fault. 10. Battery 2 under 11.5V fault: Battery 2 low voltage fault. 11. Battery under 22V while charging fault: Catastrophic battery fault where total battery voltage is less than 22 volts when charging is applied. The log is scrolled through by pressing the down key and the log events will be displayed in chronological order, most recent displayed first. When the end of the log is reached this message -----End of Log---- will be displayed. If the log is empty, No faults logged will be displayed when attempting to view the log: Multiple events of one type will only be appear once in the log to prevent the log from overfilling. Erase Fault Log This menu erases the current log enabling fresh events to be recorded. When enter is pressed the log will be erased and the display will show: log erased Calibration O/P1 fuse fault The calibration menu allows on-site calibration of the PSU. All PSUs are calibrated at the factory as a part of their automated test procedure and normally do not require calibrating for the rest of their service lifetime. However in extreme circumstances, e.g. operating in extremes of temperature, recalibration can be worthwhile. Page 9 of 10

Calibrate Charging Voltage Calibration Voltage Calibrate Battery Current Monitor Disconnect BAT1 Calibration Voltage Calibrate Output 1 Current Monitor Test Will Pulse O/P! Calibration Voltage Calibrate Output 2 Current Monitor Test Will Pulse O/P! Calibration Voltage Calibrate Charging Voltage When enter is pressed the display will show: Calibration Done After a short pause this display will be replaced with: Temperature = 31.0C Charging Voltage: Actual = 26.90V Ideal = 26.90V+/-0.07V This display is described under the Temperature Compensation status section. Note: There is a hidden Advanced Information screen that can be accessed by pressing the down arrow. This information is useful only to trained technicians. Calibrate Battery Current Monitor Before calibrating, battery 1 must be disconnected as prompted. If the battery is not disconnected then Disconnect Battery! will be displayed and the procedure will have to be started all over again. When the calibration is completed successfully the display will show: Calibration Done Note: There is a hidden Advanced Information screen that can be accessed by pressing the down arrow. This information is useful only to trained technicians. Calibrate Output 1 When enter is pressed the display will show: Calibration Done Note: There is a hidden Advanced Information screen that can be accessed by pressing the down arrow. This information is useful only to trained technicians. Calibrate Output 2 Please see above. Page 10 of 10