Agilent 5DX 8.50 Software Release Notes

Similar documents
Material Created By: Jeremy Pemberton-Pigott. Technical Marketing Engineer for AXI (Singapore) Page 1

Socket Algorithm Setup

Agilent s AXI History

This document is divided into the following sections.

Agilent Medalist 5DX Automated X-Ray Inspection (AXI) Quad Flat No-Lead (QFN) Best Practices. Application Note

AXI Applications with BTC and Connectors in Flextronics

1 INTRODUCTION. Solder paste deposits on grid array of soldering pads. SPI system integration in a PCB assembly production line

APPLICATION SPECIFICATION

3 D A O I s y s t e m. BF-3Di. The inspection ability is improved drastically by the height measurement of all parts.

Application Note AN-289

because inspection matters

Release Notes Version 5

Using Valor Trilogy to Generate 5DX Program Files

Reliability Study of Bottom Terminated Components

Advanced Strobe 1.0 Kit

Over 5,000 products High Performance Adapters and Sockets Many Custom Designs Engineering Electrical and Mechanical ISO9001:2008 Registration

Adapter Technologies

Model Table. Series. RIXO series. RIX30 series 30 illumination. RIX45 series 45 illumination

3D AOI system. BF-3Di series NEW. The 3D AOI system that meets every need in the market.

2 PIECE BOARD-TO-BOARD

Advanced Lantern 1.0 Kit. Introduction to the Advanced Lantern 1.0 Kit

Applications Overview...

Application Guidelines for Non-Isolated Converters AN09-002: Block Pin Solder Joint Guidelines

New Opportunities for 3D SPI

Release Notes Version 5

Advanced BGA Rework Station. Suitable for all kind of reworks on different SMT components

Release Highlights for BluePrint-PCB Product Version 3.0

Construction of Industrial Electronic Equipments

OptiCon X-Line 3D. Combined 3D X-ray and Optical Inspection at Production Line Pace

Agenda. ITC Board Test Tutorial Part 1, Last revised: September, Slide 1

CHEMINSTRUMENTS DYNAMIC SHEAR TESTER MODEL DS-1000 OPERATING INSTRUCTIONS

Epigap FAQs Part packges and form factors typical LED packages

Release Highlights for CAM350 Product Version 11.0

DesignCAD 3D Max 22.1 Release Notes

Release Highlights for CAM350 / DFMStream 12.2

Products, Services & Capabilities

Digital Candle 1.0 Kit

What's New in Autodesk Revit Structure 2013? Rebecca Frangipane - KJWW Engineering Consultants

Autodesk Fusion 360 Training: The Future of Making Things Attendee Guide

Design and Assembly Process Implementation for BGAs

PCB Assembly System Set Up for Pop. Gerry Padnos. E mail: smt.com

Release Highlights for CAM350 Product Version 11.0

Akrometrix Testing Applications

SMD Reflow Soldering Guide. Version 1.2

Chief Architect X Update Notes

SPRINT 4510 Release Note

Release Highlights for CAM350 Product Version 11.0

Images Scientific OWI Robotic Arm Interface Kit (PC serial) Article

Stratix II FPGA Family

Vi Technology 3D Solder Paste Inspection Solutions

Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters

STEP Model Support in PCB Editor

Development of an automated bond verification system for advanced electronic packages

UM2356 User manual. VL53L1X API user manual. Introduction

Table of Contents. Unpacking and Inspection Setup Loading the Media Mount the Printer on the Wall... 16

Adapter guide for C167/ST10, emulators

Release Bulletin DataWindow.NET 2.5

PROCESSING RECOMMENDATIONS

Release Highlights for CAM350 Product Version 10.7

Scanvec Amiable Contour Cutting Guide

Digital Flame 1.0 Kit

Release Notes RESOLVED NEW NEW

SA International Contour Cutting Guide

Application Note AN Power QFN Technology Inspection Application Note

Socket Mounting Recommendations and Reflow Profile

The Basic Counter. Hobby Electronics Soldering Kit. Instruction Guide

Modeling a Gear Standard Tools, Surface Tools Solid Tool View, Trackball, Show-Hide Snaps Window 1-1

Using the PCB Component Wizard

Questions? Page 1 of 22

OptiCon X-Line 3D: AXI and AOI teamed up

Exercise 1. Section 2. Working in Capture

APPLICATION SPECIFICATION TITLE PAGE REVISION

Upgrading. the Upgrading to Microsoft Dynamics GP 2015 Hot Topic.

E-tec Socketing solutions for BGA, LGA, CGA, CSP, MLF & Gullwing chips

2 Creating Xnets and Differential Pairs by Assigning Signal Models

Nuscan 3200 Optical Laser Barcode Scanner

Intel 815 Chipset Family: Graphics and Memory Controller Hub (GMCH)

RobWin7 instruction manual

edrive RAM Battery Alternate Replacement Procedure

Dual Head Flying Probe System. Application : Circuit Board and BGA Rework

MicroHAWK ID Demo Kit Setup Guide. P/N Rev A

Materialise Magics 23. What s new

Release Highlights for BluePrint 5.1

QLabel-IV Operation Manual

TB-2026 PROCESS FOR INSTALLATION OF PRESS FIT VHDM BACKPLANE CONNECTORS. Revision G

Steinbichler T-Scan Plugin

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17

Failure Analysis Report for Customer XXXXXXXXXX Inc.

Ceramic Surface Mount Mounting Pad Dimensions and Considerations

TestJet/VTEP Hardware Description and Verification

FlowCAD. FlowCAD Webinar. OrCAD / Allegro PCB Editor Trucs et astuces November 2012

PRELIMINARY APPLICATION SPECIFICATION

Project curves, points, or sketches onto faces and planes.

Patented socketing system for the BGA/CSP technology

Table of Contents. iii

AVR-M Rev 5 ASSEMBLY

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

JOINT MVC. Chapter Contents

EMC Guidelines for MPC500-Based Automotive Powertrain Systems

Transcription:

Agilent 5DX 8.50 Software Release Notes This information is found in the What s New In This Release Bulletin link on the 5DX and TDW. Highlights As part of our continuing software enhancement and support service, Agilent Technologies is releasing the new 5DX 8.5 software to our valued customers. This is part of Agilent's software update service that provides additional value to the 5DX system by offering new or improved algorithms, new user interface capability, and correcting known software defects. The highlights of the 8.5 software release include: A new algorithm called "FET". A new FET algorithm family has been developed to address leadless design MOSFET packages that have large pads for efficient heat dissipation. Some pad designs for the source pin of the device may have gaps inbetween, or consist of isolated sub-pads. The ability of the algorithm to perform slope and gap measurements helps to detect potential Open and Insufficient defects. The Voiding algorithm for FET family uses the learned or Expected image concept to determine how an x-ray image of a good joint compares with the one under analysis, highlight the potential void areas, and calculates the void area percent. Update to the Chip algorithm. A new pad design shaped like a letter T allows chip components to be oriented at a 45-degree angle and placed closer together, thus maximizing real estate on the PCB. This T-shirt pad design produces a solder profile that is different from conventional chip components due to presence of side fillets on both pads. New thresholds under the Chip algorithm family allows additional side fillet measurements to be performed so as to detect potential defects such as Open and Insufficient more effectively. Update to the Connector algorithm. Certain x-ray images of SMT connectors may show excessive shading such that default solder thickness measurements do not give an accurate profile and thus produces false calls. New thresholds have been added to enable gray level measurements so as to effectively capture the actual solder profile and therefore results in more accurate measurements and better defect detection. Update to Review Defects showing the incorrect slice. This update allows the Repair Tool v4.1 to automatically display the correct slice to the user, as well as the Review Defects mode in the 5DX Auto UI. This fix requires users to re-compile all 5DX programs in order to generate a new MixView.xml file in the RTF directory. Users may experience an error titled Error in the Auto UI, if this file does not exist. The XML file will be copied over to the RES results directory, during a test, and later sent to the Repair Tool by a change in the Automatic Reporter trcmdpro.cmd script.

Change Request Overview The "CR" numbers used below refer to the Change Request numbers in Agilent's software tracking system. CR24186 - Testlink: changing the family of a part rests all test status. Status of a component marked as "No Load" or "No Test" is reset when user changing the family of the component in assign package. The test status and load status that set before will not change when user changing the family in assign package. CR26307 - AXI 5DX: Software reloads previous program during align & map System is changing the name of the program to the previously run production program after operator chooses a different program from the Load Programs list and started an alignment. A checking is added that when user performs Align & Map, system will check if loaded panel program name and the actual panel program in machine are the same. If it is not the same, system will prompt a dialog and user has the choice to choose YES or NO. If YES, system will continue perform Align & Map with the newly loaded panel program. If NO, system will not perform Align & Map. CR26366 - Assert: SurfaceMapPoint.getTopSideMeasuredZHeightNanoMeters #1 When performing Surface Mapping for a panel for a second time, a Java Assert is thrown. Fix is done to eliminate the Java Assert. CR26367 - Assert: SurfaceMapPoint. getbottomsidemeasuredzheightnanometers #2 When performing Surface Mapping for a panel for a second time, a Java Assert is thrown. Fix is done to eliminate the Java Assert.

CR26672 - Main UI compile menu is limited to 500 programs. The program list in the compile menu in the main UI is limited to 500 programs. The load panel program menu allows for up to 2000 panels to be picked. The compile menu should show the same number of flies as the load panel menu. A checking is added to allow the number of programs to display in the UI up to 2000 programs. CR27823 - Alignment does not fail all the time for a bad alignment point. System did not detect bad alignment points for gray level. System should prompt message detecting bad alignment has failed. CR28162 - Duplicate barcodes not checked across multiple boards on a single panel. Duplicate serial number checking feature only checks for sequential duplicates. The checking does not detect duplicates on the panel as a whole. A checking is added to detect duplicate serial numbers across the whole panel, instead of consecutive duplicate serial numbers. This changes apply to barcode serial numbers and manual input board serial numbers. CR28218 - Manual board alignment on multiboard panel allows wrong alignment points. During initial manual alignment, it is possible to align to the wrong board on a multiple board panel. Added a checking in Manual Alignment to allow user to only align within 1 inch of distance from original location. If align more than 1 inch, system will prompt a warning message and user will be brought back to the affected view. CR28371 - AXI Review Defects: BGA pin number mismatch between review defect image and list. BGA pin number shown in Image Window does not tally with the BGA pin number shown in Review Defect component list. Pin number that shows in the review defect will same as the Image Window.

CR28477 - Panel with x-out board tested last then no res/log file saved/sent to ITF. If you have a panel with three boards and the third board tested is x-out then no.log file is created for this third board serial number. After each test, all res files and log files should be created for each board on the panel. CR28857 - Casper 101954 - SMEMA outputs incorrectly set in Automatic Review mode. Panel results not updated in Auto-Review mode. Changes added in BoardInspectionEnd function in TestExecution file to update panel test result based on current board RES file. CR29452 - Short threshold "Test region" not showing correct information when first shown. During execution of Algorithm Tuner, the Test Region parameter under Short threshold will be displayed as default value. In original code in Algorithm Tuner, if column not editable, it will update all columns to default value, including user settings during runtime (column not editable). Changes made to only update the default column and not user settings. CR29633-5DX X-ray Scan Calibration. X-ray Scan calibration does not always start from 400 FOV (base FOV). X-ray Scan Calibration will always adjust 400 FOV (Base FOV) before adjust other FOV. CR29804 - AXI 5DX: Software hangs when aborting manual alignment. If we set to trigger Auto-Review after each inspection, 5DX hangs when automatic alignment fails. occurred when user triggered Auto-Review feature for inspection. When user aborted the inspection half-way through Alignment/Surface Mapping, Test Execution will hang. Changes made to fix the hang problem.

CR30201 - AXI Testlink: Review Measurement "Default Configuration" function is incorrect. In Review Measurement, when selecting Options > Default Configuration, this will incorrectly change the algmet.cfg file from FilterPath=\5DX\FILTER to FilterPath=\FILTER. In review measurement, default configuration will always set the FilterPath to \5DX\FILTER CR30318 - Misfocused images: Topside Reference Point from wrong panel is used. Any view that does not use 400 FOV will be very misfocused when running Align and Map. Surface-Map-Alignment is not running as it should as part of Align and Map process. Fix is done to get the current panel reference offset. CR30319 - Align and Map misfocused images: surface-map-alignment-views not working. Any view that does not use 400 FOV will be very misfocused when running Align and Map. Surface-Map-Alignment is not running as it should as part of Align and Map process. Fix is done to get the current panel reference offset. CR30320 - Aligning on two-row components or single caps or resistors does not work. If you have an alignment view that uses pads from a single component, and that component has only two rows of pins, you can get an alignment failure or it will lock onto the wrong pins. Fixed. CR30366 - Assert: loadpanelasynchronously(panelloadingserver.java:66). Java assert is thrown if board width is smaller than width specification. Panel size checking added when user loads board into 5DX machine. If board width out of spec, system will throw an exception.

CR30426 - AXI 5DX: Review defect shows wrong image. Wrong slice of image shown in Review Defect. i) Generating an external XML file every time compiling the project from ndf to rtf. ii) This XML file store the valid slices to test for each view. iii) In every time in review defect (5dx menu / tdw), each defect pin will trace the records in xml file to get the valid slices index before show in the image window. If there is no record found in xml files, it will show the original slices index in res file. CR30484 - Assert: setsinglefamilyallalgorithms(paneltestsettings.java:92). Java assert. Fixed. CR30489 - Assert: setalignmenttimeinmilliseconds(imageanalysisserver.java:300). Java assert. Fixed. CR30539 - New edge port drivers are not a part of the current 5DX software release. New edge port drivers are not included in 5DX software installer. Every time install the 5dx, it will delete the old version of edge port driver, and install the new driver (for 5000 series). CR17650 - Excess algorithm be added to the PressFit Connector algorithm. Unable to detect open pins when a corner of a package is lifted, leaving just the solder on the pad. A new Excess algorithm added into PressfitConnector. At a high level, it should work in opposite from the way that the PressfitConnector Missing Algorithm (like Insufficient) works.