Data sheet 6852 Page 1/11 Contact Dial Thermometers FL 21 Special features Class 1.5 Display range -4 C to +6 C Temperature controller with actual value display as built-in or add-on device in a stainless steel case with 1 or 2 microswitches Case sizes : 6 mm, 8 mm, and 1 mm Front panel: 72x72 mm and 96x96 mm Brief description Contact dial thermometers are devices with an actual value display for temperature measurement, control, and monitoring and can be used universally. The temperature-dependent volume change in a measuring system filled with liquid or the temperature-dependent pressure change in a measuring system filled with gas is converted to a rotational movement of the actual value indicator by a bourdon tube; no transmission gear is required. The microswitch is actuated by the rotational movement of the indicator shaft via a tap system. Type 6852/238 Contact dial thermometers in the series 6852 are RoHS-compliant and cadmium-free. Technical data Type 6855/18 Case and front panel Stainless steel (1.431) Cover cap Plastic (PA6), gray, UV-stabilized Protection type IP 54 according to DIN EN 65 Front pane Acrylic glass (PMMA) Chassis Aluminum (3.2582.5) Scale White, with black lettering Display Class 1.5 similar to DIN EN 1319 Strain relief spring For capillary devices on the case and the temperature probe Setpoint value adjustment By setpoint adjuster in the front pane Display correction On the rear Limit value temperatures For transport and storage -3 C to +7 C (for display range -4 to +4 C up to max. 5 C; -3 to +5 C up to max. 6 C) Rated position (NL) Any
Data sheet 6852 Page 2/11 Technical data Display range (AB) Display range in C Measuring range in C Tolerance in K (+/-) 469-4 to +4-3 to +3 1.5 643-2 to +12-2 to +12 3. 87 to +6 +1 to +5 1.5 814 to +1 +1 to +9 1.5 818 to +12 +2 to +1 3. 832 to +2 +2 to +18 3. 84 to +3 +3 to +27 6. 848 to +4 +5 to +35 6. 854 to +5 +5 to +45 8. 858 to +6 +1 to +5 1. Liquid filling Gas filling Measuring system Display range (AB) 35 C Display range (AB) 4 C Time constant.632 Approx. 12 s, measured in water, with a probe Ø of 6 mm made of copper. Approx. 4 s, measured in oil, with a probe Ø of 1 mm made of stainless steel. Ambient temperature influence effect In % of the display range (referring to the deviation from the reference value +23 C) On case On capillary (per m).15% of the display range per K ambient temperature change.5% of the display range per K ambient temperature change.3% of the display range No influence per K ambient temperature change At higher ambient temperature higher temperature display lower switching point Standard Extra code (TZ) 65 Electrical contact Contact type Single-pole microswitch with mechanically actuated changeover contact Switching capacity AC 23V, +1/-15%, 48 to 63Hz, cos ϕ = 1 (.6) 5 (1.5) A 1 (3) A Switching differential Approx. 1.5% of the display range 1.5 to 3% of the display range Switching point accuracy ±.5% of the display range referring to the switch-off point with rising temperature Switching reliability To ensure a high switching reliability, we recommend a minimum voltage of 24 V and a minimum current of 1 ma Electrical connection Standard Design type 2 and 22 Design type 1, 23, and TZ 426 Screw terminals, connection cross-section up to 2.5 mm2 Connection cable.5 m with screw terminals Cover cap with cable fitting, suitable for cable Ø from 6.5 to 13 mm Case 6 mm Cover cap with cable fitting, suitable for cable Ø from 8 to 1 mm
Data sheet 6852 Page 3/11 Dimensions 6852/28 L S 42 ( 1 ) ( 1 ) Connecting cable.6 m long with screw terminal 6852/21 Ø1 L S 42 ( 1 ) ( 1 ) Connecting cable.6 m long with screw terminal 6852/18 44,5 36 4 17,5 L S ( 2 ) ( 2 ) Active probe dimension
Data sheet 6852 Page 4/11 6852/11 44,5 36 17,5 S 4 Ø1 L ( 2 ) ( 2 ) Active probe dimension 6852/26 85 75 8 2 Ø 6 Ø 65 3,6 3x 12 Ø 6 mm = 62 mm 6852/28 Ø11 Ø 95 Ø4,8 12 11 14 2 1 4 22 21 24 16,5 3x12 Ø 8 mm = 62 mm
Data sheet 6852 Page 5/11 6852/21 Ø132 Ø116 Ø1 12 11 14 2 1 4 22 21 24 16,5 Ø4,8 3x12 Ø 1 mm = 1 mm 6852/216 69 27 6,3 28 Ø65 Ø6 Ø 6 mm = 62 mm 6852/218 89 44 12 11 14 2 1 4 22 21 24 16,5 Ø 8 mm = 62 mm 6852/211 19 44 Ø1 16,5 12 11 14 2 1 4 22 21 24 Ø 1 mm = 1 mm
Data sheet 6852 Page 6/11 6852/228 Ø Ø 11 95 1 12 Ø4,8 3x12 45 ( 1 ) ( 1 ) Connecting cable.6 m long with screw terminal 6852/221 Ø132 Ø116 1 11 Ø1 Ø4,8 3x12 45 ( 1 ) ( 1 ) Connecting cable.6 m long with screw terminal 6852/238 44,5 36 49 22 17,5 43 Ø7 5 ( 3 ) Spigot Ø 2 mm 8 ( 3 )
Data sheet 6852 Page 7/11 6852/231 44,5 36 59 17 43 22 Ø1 ( 3 ) Spigot Ø 2 mm Ø7 5 8 ( 3 ) 6852/2572 H72 68 5 22 Ø6 27 Panel cut-out for front panel 72x72mm=Ø62 mm 6852/2596 96 44 68 5,3 22,8 12 11 14 2 1 4 22 21 24 16 5 Panel cut-out for front panel 96x96mm=Ø82 mm oder 96x96mm=92x92 mm (TZ 46)
Data sheet 6852 Page 8/11 Order details Order code ( 1 ) Basic type 6852 Mechanical contact dial thermometer, class 1.5 6855 Mechanical contact dial thermometer, class 1.5, transformer version (only basic type extension 18) ( 2 ) Basic type extension Case size Ø 28 Design type 2 8 mm 21 1 mm 18 Design type 1 8 mm 11 1 mm 26 Design type 2 6 mm 28 8 mm 21 1 mm 216 Design type 21 6 mm 218 8 mm 211 1 mm 228 Design type 22 8 mm 221 1 mm 238 Design type 23 8 mm 231 1 mm 2572 Design type 25 Case size 2596 72 x 72 mm 96 x 96 mm ( 3 ) Display range in C 469-4 to +4 643-2 to +12 87 to +6 814 to +1 818 to +12 832 to +2 84 to +3 848 to +4 854 to +5 858 to +6
Data sheet 6852 Page 9/11 Order code ( 4 ) Capillary type (FL) a Without (with rigid connection) 2 FL 2 Cu capillary with Cu textile braiding, approx. Ø 2.5 mm (up to AB end value +3 C) 11 FL 11 Cu capillary with PE coating, approx. ø 3.5 mm (up to AB end value +12 C) 17 FL 17 Stainless steel capillary, approx. Ø 1.5 mm 21 FL 21 Cu capillary, approx. Ø 1. mm (up to AB end value +3 C) ( 5 ) Capillary length b Without (with rigid connection) 1 1 mm 2 2 mm 3 3 mm 4 4 mm 5 5 mm.... Special length (specifications in plain text: 1, mm increments, maximum length 6, mm), additional lengths upon request ( 6 ) Process connection (PC) a 75 TF 1 Temperature probe with stepped support tube 752 TF 11 Temperature probe without support tube 843 TA 2 Protection tube with union nut and loose screw connection b 161 TA 3 Protection tube with loose screw connection 847 TA 6 Protection tube with displaceable threaded fitting on support tube b 311 TA 2 Protection tube with loose screw connection and connection collar b 872 TA 21 Protection tube with loose pressure screw and conical seal (only G 3/8 possible) 873 TA 22 Protection tube with loose pressure screw, conical seal, and loose screw connection b 874 TA 24 Protection tube (CuNi) with screw connection (CuZn), O ring seal and clamping screw a b 41 TA 23 Protection tube with pressure screw and contact pressure spring (only M 1x1 possible) 913 SH 7 Screw-in protection tube, multi-sectional, with clamping piece and fixing screw (suitable for TF 1 and TF 11) 82 SH 9 Weld-in protection tube, multi-sectional, with clamping piece and fixing screw b (not for FL 21 welding collar with steel 1.4515) 876 SH 1 Screw-in protection tube, multi-sectional b (suitable for TA 21) 871 SH 11 Screw-in protection tube, multi-sectional b (suitable for TA 23) a For the description and special features refer to data sheet 6873. b Screw-in spigot according to DIN 3852, form A.
Data sheet 6852 Page 1/11 Order code ( 7 ) Ø Process connection (PC) a 6 6 mm 8 8 mm 1 1 mm 11 11 mm 12 12 mm ( 8 ) Thread type of process connection (PC) a Without thread (for TA 1 and TF 11) 13 Screw connection G 3/8 14 Screw connection G 1/2 15 Screw connection G 3/4 114 Screw connection M 1 x 1 (only with TA 23) ( 9 ) Material, probe / support tube a 26 Stainless steel (CrNi, 1.4571) 96 Copper (Cu) / Brass (CuZn) (up to 2 C) 95 Stainless steel (CrNi, 1.4571) probe / brass (CuZn) support tube (from 25 C) ( 1 ) Material of process connection (PC) a Without (only TF 1 and TF 11) 26 Stainless steel (CrNi, 1.4571) 46 Brass (CuZn) ( 11 ) Insertion length, process connection (PC) a (dimension "EL" or "S") Minimum insertion length TF 11 (active probe dimension) 5 5 mm 1 1 mm 15 15 mm 2 2 mm... Special length (specifications in plain text 5 mm increments) a For the description and special features refer to data sheet 6873.
Data sheet 6852 Page 11/11 Order code ( 12 ) Switching output 2 1 changeover switch 21 2 changeover switches 22 2 changeover switches in fixed sequence ( 13 ) Extra codes (TZ) Without extra code 426 Cover cap to protect the screw terminals against contact and spray water (standard for design types 1 and 23; not for design type 22; not in connection with TZ 46) 43 Drag indicator (includes TZ 477) 46 Device centering for panel cut-out 92 92 mm (only for basic type extension 2596) 477 Setpoint adjustment protected by the bolted cover. Adjustment with screwdriver. 518 Stop for Min. or Max. setpoint value limitation, default setting 522 Customized scale 65 Microswitch 1 (3) A (AC/DC 23 V, +1/-15%, 48 to 63 Hz, cos ϕ = 1 (.6) ) Special versions upon request! Order code ( 1 ) ( 2 ) ( 3 ) ( 4 ) ( 5 ) ( 6 ) ( 7 ) ( 8 ) ( 9 ) (1) (11) (12) (13) 6852 /.... -... -.. -.... -... -.. -... -.. -.. -... -.. /...,... Order example 6852 / 21-818 - 21-2 - 14-1 - - 26 - - 1-2 / 65 a,... a List extra codes in sequence, separated by commas. Stock versions Part no. Type Display range C 455918 6855/18-643-874-8-16-5-15-2/434-522 with drag indicator 455919 6855/18-643-874-8-16-5-15-21/434-522 with drag indicator Switching output Temperature probe, process connection Protection tube mm -2 to +12 2 (1 contact) TF 5 d = 8 mm 21 TA 24, G 1", CuZn 15 (2 contacts) Delivery within 3 working days after receipt of order