Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

Similar documents
Safety Control. Safety.

Safety Control. Safety. Selection Guide Safety Relay HR1S-AC Safety Relay HR1S-AF

HR1S-AC Safety Relay Modules

Safety Switches CES-AR/CET-AR

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

SR B series coded magnetic safety sensors

Datasheet - AZM300Z-ST-1P2P-A

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

Datasheet - MZM 100 B ST2-1P2PW2RE-A

Safe switching and monitoring Non-Contact Safety Sensors

Coded magnetic safety sensor SR B series

Coded Non-Contact Safety Sensor Eden OSSD

Datasheet - MZM 100 B ST-1P2PW2REM-A

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

Safety coded magnetic sensor SR A series

Safety coded magnetic sensor SR B series

Safety Monitoring Relays

SR A series coded magnetic safety sensor

Safety switches with manual mechanical delay and separate actuator

SA1E: Photoelectric Switches. Polarized Retroreflective Type. Through-beam Type

Thread length (overall length) material

J8 SWITCHES WITH TRIP FUNCTION UPGRADED TYPE

Expansion Unit G9SX-EX Safety 2 Instantaneous safety outputs

Making Hazardous Operations Safe and Productive

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

Tongue Switches Visit our website: Interlock. Switches. Safety Switches. Trojan 5 & 6. Specifications.

Intrinsically Safe Explosion Proof Barriers

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

AS-Interface Safety at Work

Datasheet - RSS 36-D-R-ST

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

Safety Relay Unit (I/O Unit Type)

Safety Monitoring Relays

Timers. GT3W Series Dual Time Range Timers. 250V AC/150V DC Time Range. 1: 0.1sec to 6 hours, 3: 0.1sec to 300 hours

F3S-B. Safety Design for Category 2. Suitable for Detecting Human Bodies in a Dangerous Area. Safety Light Curtain. Features

XCSRC10M12 Safety RFID contactless switch - Single model - Unique pairing

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Safety switches with manual mechanical delay and separate actuator

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs. Safety Contacts. Auxiliary Contacts

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Locking Type. Power Supply. Operating Radius, Min

Non-Contact Safety System CES-AZ

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC

Light Curtains. Type 4 SG4. Type 4 SG4 Series. 468

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

Safety Switches CES-AR/CET-AR

Safety coded magnetic sensor SR B series

Safety coded magnetic sensor SR A series

Magnetically Actuated Safety Interlock Switches

G9SX-LM. Low-speed Monitoring Unit. Low-speed Monitoring Function Ensures Safety for Maintenance Work. Model Number Structure.

H3CR-F H3CR-F8 H3CR-F-300 H3CR-F8-300

Table of Contents LED Machine Lighting - Pg. 1 Automation & Sensing - Pg. 27 Safety - Pg. 255 Switching & Controls - Pg. 449 Index - Pg.

FS1A Safety Controller

RTE Series Analog Timers. UL Listed File No. E kPa to 110kPa (Operating), 70kPa to 110kPa (Transport)

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing

Tecnología en Electrónica y Control SRL Ficha Técnica

Datasheet - AZM 200SK-T-1P2PW

Safety. Detection. Control. MAGNUS RFID ENG - REV

Datasheet - CSS 11-30S-D-M-ST

Datasheet AZM 161 Z ST1 AS RA

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

FS1A Safety Controller

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

HR1S Safety Relay Modules

Timers. RTE Series. RTE Series Analog Timers. Specifications. G-8 USA: (800) 262-IDEC or (408) , Canada (888) 317-IDEC

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.

SensaGuard. Description. Features. Benefits. Specifications

Magnetically Actuated Safety Interlock Switches

Compact Magnetic Non-contact Safety Switches. Model Number Structure

Compact Coded Magnetic Safety Interlock Switch and Control Units

Safety switches with separate actuator

Communication & Networking

Tongue Switches Trojan 5 & 6

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Safety Systems Safety Integrated

Datasheet - SRB 301LC/B-24V

Transponder-coded. with guard locking

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

MSR178DP. Description. Features. Specifications

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Communication & Networking

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches

Compact Magnetic Non-contact Safety Switches. Model Number Structure

Remote I/O Unit with Connectors for Light Curtain CC-Link Safety System. panasonic.net/id/pidsx/global

Ultra Slim Relays 24

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C

Safety hinge switches HX series

Pneumatic Control/Feedback

Communications & Networking

Pneumatic Control/Feedback

Datasheet - AZM 200 BZ ST-T-AS P

Safety Products Introduction LS-Titan Safety Interlock Switches. Technical Reference... 2

Transcription:

HSA-DMC Magnetic Safety Switches Key features: Compact size and easy positioning. Combination with proprietary relay modules achieves safety category 4 (EN954-1). Compact size ( 16 51mm) Positioning for installation is easy. Up to 36 sets can be connected. (safety relay module: HR1S-DME) Degree of protection: IP6 Part Numbers HSA Non-contact Magnetic Accessory Contact Configuration 1NO 1NC 2NO Cable Length 2m 5m 10m 2m 5m 10m Part Number HSA-DMC5902 HSA-DMC5912 HSA-DMC5905 HSA-DMC5915 HSA-DMC59010 HSA-DMC59110 HSA-DMC902 HSA-DMC912 HSA-DMC905 HSA-DMC915 HSA-DMC9010 HSA-DMC9110 Applicable Safety Relay Module HR1S-D HR1S-AF Name Part Number HS9Z-ZC1 One HS9Z-ZC1 is supplied with each HSA-DMC non-contact interlock switch. Maximum Number of Connectable Non-contact Interlock Switches per Input of Safety Relay Module Non-contact Interlock Switch HSA-DMC59 HSA-DMC9 HR1S-D 6 3 HR1S-AF 6 1 The HSA-DMC non-contact interlock switch is supplied with an HS9Z-ZC1 actuator. The contact configuration in the table above shows the contact status when the non-contact interlock switch is not activated. HR1S Safety Relay Modules for Non-contact Safety Relay Module Voltage Number of Inputs Max. Number of Connectable Non-contact HR1S-DMB 32 2 12 24V DC 20 to 20% HR1S-DME 32 6 36 24V AC 15 to 10% 50/60 Hz HR1S-AF 30B 1 6 24V DC 15 to 10% Safety category 3 can be achieved when connecting two or more non-con tact interlock switches per one input. When connecting multiple non-contact interlock switches (HSA-DMC90 ), use HR1S-AF51. (HSA-DMC91 cannot be connected in multiple numbers.) 342 www.idec.com

Standard Interlock Safety Switches HS6B Applicable Standards Operating Temperature Relative Humidity Storage Temperature Pollution Degree 3 IEC/EN 6094-5-1 UL508 (UL listed) CSA C22.2, No. 14 25 to 85 C (no freezing) 30 to 85% RH (no condensation) 40 to 85 C (no freezing) Electric Shock Protection Class II (IEC 60536) Degree of Protection IP6 (IEC 60529) Shock Resistance 300 m/s 2 (11 ms) (IEC 60068-2-) Vibration Resistance 100 m/s 2 (10 to 150 Hz) (IEC 60068-2-6) Rated Voltage (Ue) Rated Current (Ie) Repeat Accuracy Maximum Operating Frequency Voltage Drop Housing Material Housing Color Cable Weight (approx.) I = 10 ma I = 100 ma 24V DC 100 ma 10% maximum 150 Hz 0.1V (without ) / 2.4V (with ) 1V (without ) / 4.2V (with ) PBT Red AWG23 4 Cable length: 2m, 5m, 10m HSA-DMC: 100g (cable length: 2m) HS9Z-ZC1: 9g Dimensions (mm) HSA-DMC (Non-contact Interlock Switch) 16 8 2-ø6 2-ø3.5 16 12.5 3.5 51 HS9Z-ZC1 () 3.5 51 16 16 8 Minimum Radius 30 mm 2-ø6 2-ø3.5 800-262-IDEC (4332) USA & Canada 343

HSA-DMP Magnetic Safety Switches Key features: Three-contact models. Auxiliary contacts enable PLCs to moni tor the door status. Operation signals from auxiliary contacts can be read directly by controllers such as PLCs, allowing for monitoring HSA-DMP non-contact interlock switches. Ideal for installation on guard doors where positioning is diffi cult. Conformable up to safety category 4 (EN ISO 13849-1) (Combining with proprietary safety relay module achieves safety category 4.) A maximum of 36 sets can be connected (safety relay module: HR1S-DME) Degree of protection: IP6 The HSA-DMP non-contact interlock switches can be used as interlock switches when used in combination with safety relay modules specified by IDEC. Part Numbers HSA Non-contact Contact Configuration 1NO2NC 2NO1NC Cable Length 2m 5m 2m 5m Ordering Type No. HSA-DMP5002 HSA-DMP5012 HSA-DMP5005 HSA-DMP5015 HSA-DMP002 HSA-DMP012 HSA-DMP005 HSA-DMP015 Applicable Safety Relay Module HR1S-D HR1S-AF The HSA-DMP non-contact interlock switch is supplied with an HS9Z-ZP1 actuator. The contact configuration in the table above shows the contact status when the non-contact interlock switch is not activated. HR1S Safety Relay Modules for Non-contact Safety Relay Module Number of Inputs Max. Number of Connectable Non-contact HR1S-DMB 2 12 HR1S-DME 6 36 HR1S-AF 1 6 When connecting multiple non-contact interlock switches (HSA-DMP00 ), use HR1S-AF. (HSA-DMP01 cannot be connected in multiple numbers.) Accessory Name Part Number HS9Z-ZP1 One HS9Z-ZP1 is supplied with each HSA-DMP non-contact interlock switch. Maximum Number of Connectable Non-contact Interlock Switches per Input of Safety Relay Module Non-contact Interlock Switch HSA-DMP50 HSA-DMP0 HR1S-DM 6 3 HR1S-AF 6 1 346 www.idec.com

Solenoid Locking Safety Switches HS6E Applicable Standards Operating Temperature Relative Humidity Storage Temperature Pollution Degree 3 IEC/EN 6094-5-1 UL508 (UL listed) CSA C22.2, No. 14 25 to 85 C (no freezing) 35 to 85% RH (no condensation) 40 to 85 C (no freezing) Electric Shock Protection Class II (IEC 60536) Degree of Protection IP6 (IEC 60529) Shock Resistance 300 m/s 2 (11 ms) (IEC 60068-2-) Vibration Resistance 100 m/s 2 (10 to 150 Hz) (IEC 60068-2-6) Rated Voltage (Ue) Rated Current (Ie) Repeat Accuracy Maximum Operating Frequency Voltage Drop Electrical Durability Housing Material Housing Color Cable Weight (approx.) I = 10 ma I = 100 ma 24V DC 100 ma 10% maximum 150 Hz 0.1V (without ) / 2.4V (with ) 1V (without ) / 4.2V (with ) 1,200,000 operations minimum PBT Red AWG23 6 Cable length: 2m, 5m HSA-DMP: 180g (cable length: 2 m) HS9Z-ZP1: 50g Dimensions (mm) HSA-DMP (Non-contact Interlock Switch) HSA-ZP1 () 800-262-IDEC (4332) USA & Canada 34

HS3A Non-contact RFID Safety Switches Key features: RFID non-contact interlock switch, Category 4 and PLe (EN/ISO 13849-1) compliant. The sensor head with built-in safety function (redundant solid state output with internal monitoring) eliminates the need for a designated safety module. RFID ensures detection of slow-moving, open, sliding, and rattling doors. Multicode and unicode sensor heads are available. Unicode sensor head (one sensor head corresponds to one actuator) prevents tampering with the use of an unassigned spare actuator. Sensor head can be installed in 5 directions. Degree of protection IP6. IP6, IP69K (Note) Note: IP69K is a degree of protection specified by Deutsches Institüt für Normung (DIN), DW 40050 Part 9 for hot and high-pressure water. Interlock Switch (Sensor Head) Part Numbers HS3A Non-contact RFID Safety Switches Outputs Type Part Number Safety output: 2 Monitor output: 1 Multicode Unicode HS3A-H21M4 HS3A-H21U4 Accessories Name Part Number Remarks HS9Z-ZH31 for both multicode and unicode sensor heads. Supplied with two M5 10 mounting screws (stainless steel) Terminal Plug (For serial connection) HS9Z-H3TP Used on Y-branch connector when connecting two or more switches in series. Y-branch Connector (For serial connection) M12 Plug Connection Cable For connecting two or more switches in series 5-pin, 5m 5-pin, 10m HS9Z-H3YD HS9Z-H3F505 HS9Z-H3F510 Used when connecting two or more switches in series. Plug connector: 8-pin (switch side), 5-pin (cable side) Used when connecting two or more switches in series. 5-pin plug connector is provided at one end. For connecting a single switch 8-pin, 5m 8-pin, 10m HS9Z-H3F805 HS9Z-H3F810 M12 Plug Connection Cable (For serial connection) 5-pin, 5m HS9Z-H3F5M05 5-pin, 10m HS9Z-H3F5M10 Used when connecting a single switch. 8-pin plug connector is provided at one end. See below for an example of accessories required when connecting N number of HS3A switches in series. HS3A non-contact interlock switch (HS3Z-H21 4): N pcs. (HS9Z-ZH31): N pcs. Terminal plug (HS9Z-H3TP): 1 pc. Used when connecting two or more switches in series. 5-pin plug connectors are provided at both ends. Y-branch connector (HS9Z-H3YD): N pcs. M12 plug connection cable, open end (HS9Z-H3F5 ): 1 pc. M12 plug connection cable, plug connectors at both ends (HS9Z-H3F5M ): N 1 pcs. 350 www.idec.com

Solenoid Locking Safety Switches HS6E Applicable Standards Operating Temperature Relative Humidity Storage Temperature Pollution Degree 3 Sensor Classification EN6094-5-3 (IFA approval) EN954-1 EN ISO13849-1 EN62061 GS-ET-14 (IFA approval) UL508 (UL listed) CSA C22.2 No.14 (c-ul listed) 20 to 55 C (no freezing) 5 to 80% (no condensation) 25 to 0 C PDF-M (EN6094-5-3) Performance Level (PL) e (EN ISO 13849-1) Safety Category 4 (EN ISO 13849-1) Safety Integrity Level (SIL) 3 (EN 62061) Degree of Protection Interlock Switch (sensor head) IP6 IP6, IP69K (Note) Rated Voltage (UB) 24V DC ±15% Current Consumption Dielectric Strength Output Operation Distance Response Time Shock Resistance Vibration Resistance Material Cable Weight (approx.) Attachment Safety Output Monitor Output Turn-on Distance Assured Turn-on Distance (Sao) Maximum Turn-off Distance (Sar) When using a single switch When using two or more switches (max.) 80mA (at no load) 500V AC Semiconductor output, P-channel Output voltage: Max: UB [V], Min.: UB-1.5 [V] Maximum output current per safety output: 400 ma Semiconductor output, P-channel Output voltage: Max: UB [V], Min.: 0.8 UB [V] Maximum output current: 200 ma 15mm (typ.) 13mm 58mm 260 ms (actuator removed) 150 ms (non-identical input signal at IA/IB) 150 ms (non-identical enabling input state at IA/IB) 300 ms ( short-circuit or cross-circuit at OA/OB, or internal error) 360 ms (actuator removed) 250 ms (non-identical input signal at IA/IB) 400 ms ( non-identical enabling input state at IA/IB) 400 ms ( short-circuit or cross-circuit at OA/OB, or internal error) Operating extremes: 300 m/s 2 (11 ms) 10 to 55 Hz, amplitude 0.5 mm PBT M12 plug connection cable, 8-pin 400g (HS3A-H21 ) System Manual (CD-ROM) Dimensions (mm) Sensor Head 34 30 20.5 M12 1 13 ø5.2 10 4 ø5.5 Active Face 4 56.5 30 ±0.1 40 40 40.5 0 40 0.25 Active Face Supplied with two mounting screws (M5 10). Terminal Plug HS9Z-H3TP 36.5 ±0.5 M12 1 ø14.5 Y-branch Connector HS9Z-H3YD 46 M12 1 15.1 Plug 20.5 35.1 0962 M12 1 ø14.6 (45 ) Socket 42.5 800-262-IDEC (4332) USA & Canada 351

Plug Connection Cable Non-contact Interlock Switch HS9Z-H3FB HS9Z-H3FS 8 2 6 1 3 4 5 8 1 Coding Pin 6 2 5 3 4 Pin Wire Legend Description 1 White IB Enabling input (channel 2) 2 Brown UB Power supply (24V DC) 3 Green OA Safety output (channel 1) 4 Yellow OB Safety output (channel 2) 5 Gray OUT Monitoring output 6 Pink IA Enabling input (channel 1) Blue 0V 0V 8 Red RST Reset input for hardware Pin Wire Legend 1 Brown UB 2 White OA 3 Blue 0V 4 Black 0B 5 Gray RST Wiring Diagram When using a single HS3A When using a single HS3A, connect as shown in the figure below (Note). The OUT output can be connected to a control system, to a PLC for example, as a monitoring output. The HS3A can be reset via the RST input. To reset, apply 24V DC for at least 3 seconds. When not using the RST input, connect the RST input to 0V. 24V DC A1 (white) (brown) (green) (yellow) (gray) (pink) (blue) (red) S11 S21 S22 S12 S33 S34 13 23 33 41 2 b 1 a a b Relay Off Check K1 ON Control Sub Circuit K2 K1 K2 K2 K1 0V A2 14 24 34 42 1 2 3 4 5 6 8 F To PLC In the following diagram, HR2S-301P safety relay module is connected to the HS3A. RST input of HS3A is not used. IB UB OA OB OUT IA 0V RST M12 Plug Connection Cable (8-pin) HS3A #1 S1 K3 K4 ESC ESC: External Start Condition F: Fuse S1: Start Switch K3, K4: Safety Contactor Safety Output Response Time removed (Note) Failure Missing signal IA/IB Non-identical input at IA/IB Short-circuit or cross-circuit at OA/OB, or internal fault t 0 : Safety output ON t off : Output OFF time t 0 : Error/actuator removed t off =t 0 300 ms t off =t 0 260 ms t off =t 0 150 ms t (ms) Note: The time required for the safety output to turn off after the actuator moves outside the operating distance of the HS3A switch. AUTO: Short MANU: Open For details of HR2S-301P safety relay module, see the instruction sheet. K3 K4 External Output Circuit Note: Safety performance of the actual system is determined by performing a risk assessment on the entire system. Depending on the risk level the system may entail, K1 and K2 need to be monitored to prevent serious accidents. 352 www.idec.com

HS5B/HS5E Door Handle Key features: Easy and secure operation Rattling doors can be locked smoothly and securely. A door can be locked with an actuator by pushing and turning the handle. Padlock tab is provided to ensure operator safety. Interlock switch with or without solenoid lock can be installed. shows solenoid status (when using HS5E- 44L -G). Part Numbers Description Ordering Type No. Remarks Handle Unit For right-hand door For left-hand door Choose according to the required opening side. Switch Cover Unit HS9Z-DH5C Used for installing the interlock switch inside. HS5B Installation Kit HS9Z-DH5B Contains a mounting plate and two spacers. HS9Z-FL53 Contains a button with base plate Mounting panel thickness (X): 20 X 30mm 2 Rear Unlocking Button Kit 1 HS9Z-FL54 and a connecting rod Mounting panel thickness (X): 30 X 40mm 2 1. Use the kit in combination with the HS5E- 44L -G rear unlocking button type interlock switch. 2. Mounting panel is a frame or a panel. Parts Description Padlock Knob Blind Cap Handle Unit (for right-hand door) Front Handle (black) Switch Cover Unit Manual Unlock Label Interlock Switch Front View Rear View 354 www.idec.com

Solenoid Locking Safety Switches HS6E Applicable Interlock Switch HS5B Metal Head Interlock Switch 1 HS5E Rear Unlocking Button Type Interlock Switch with Solenoid 2 Operating Temperature 25 to 0 C (no freezing) Mechanical Durability 100,000 operations minimum Applicable Shackle Diameter of Padlock ø6 to.5 mm stand Load of Padlock Tab 30N maximum Handle Operation Angle (removed position inserted position) Insulation Resistance (500V DC megger) Between live and dead metal parts: 100 MΩ minimum Between terminals of different poles: 100 MΩ minimum. Rotational handle actuator can be inserted/removed smoothly on rattling doors. Conventional Sliding IDEC's Door Handle Rattling doors can be locked smoothly and securely. The door can be locked and unlocked by pushing and turning the handle. The actuator can be inserted into the interlock switch by pushing and turning 2 Turn the front handle. The actuator can be removed from the interlock switch by turning the front handle. 1 Push Padlockable tab ensures operator s safety. When padlocks are installed on the padlock tab, the machine cannot be started because the actuator entry slot is blocked and the actuator cannot enter the interlock switch. By requiring all operators to have their own padlock and installing them on the door handle actuator before entering the hazardous area, the door will not be closed unless all padlocks are removed i.e. all operators have left the hazardous area. Note: Operators must observe rules in the workplace in order to ensure safety. Residual risk such as failure to install padlocks must be taken into consideration. Interlock switch with/without solenoid locking can be selected. HS5E Because the handle can be turned only while it is pushed, the actuator is prevented from hitting the switch cover unit. (HS5E- 44L -G) HS5B (HS5B- Z) The rear handle can remove the actuator, but cannot insert the actuator. Padlock Tab Padlock Knob 1. HS5B- ZB, HS5B- ZBM 2. HS5E- 44L -G Interlock switch is not supplied with the actuator and must be ordered separately. For the specifications of interlock switches, see pages XX, XX, and XX. Sliding doors can also be locked securely. Using a hasp 800-262-IDEC (4332) USA & Canada 355

Door Handle Configuration Switch Cover Unit HS5E- 44L -G Rear Unlocking Button Type HS5B- Z Metal Head Type HS9Z-DH5C Selection Chart Door Size Large Lock Rear Unlocking Required Mounting Panel Thickness (X) X 3 mm 20 X 30 mm 30 < X 40 mm Lock X 0 mm Small Lock Lock 356 www.idec.com

Solenoid Locking Safety Switches HS6E Handle Unit Right-hand Door Right-hand Door Left-hand Door Right-hand Door Left-hand Door Right-hand Door Left-hand Door Right-hand Door Left-hand Door Handle Unit Switch Cover Unit Accessories Interlock Switch Sliding HS9Z-SH5 Left-hand Door HS9Z-DH5C Accessories Rear Unlocking Button Kit HS9Z-FL53 HS9Z-FL54 Rear Unlocking Button Kit HS9Z-FL53 Rear Unlocking Button Kit HS9Z-FL54 HS5B Installation Kit HS9Z-DH5B HS5B Installation Kit HS9Z-DH5B HS5E- 44L -G (Rear Unlocking Button Type) HS5B- Z (Metal Head Type) HS5E (All types) HS5B- Z (Metal Head Type) 800-262-IDEC (4332) USA & Canada 35