Operation and Maintenance Manual Bently Nevada Asset Condition Monitoring. 3500/25 Enhanced Keyphasor Module. Part Number Rev.

Similar documents
3500/25 Enhanced Keyphasor*Module

Operation and Maintenance Manual. 3500/42 Proximitor/Seismic Monitor Module. Part Number Rev. H (07/07)

3500/50E Tachometer Module

3500/53 Electronic Overspeed Detection System

3500/77M Recip Cylinder Pressure Monitor

3500/45 Position Monitor

3500/08 Diagnostics Access Panel

3500/77M Recip Cylinder Pressure Monitor

3500/22M Transient Data Interface

3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring

3500 ENCORE System Overview Bently Nevada* Asset Condition Monitoring

3500/22M Transient Data Interface Module

3500/45E Position Monitor

3500/32M 4-Channel Relay Module

3500/33 16-Channel Relay Module Bently Nevada* Asset Condition Monitoring

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

PART NUMBER REVISION E, 3300 SYSTEM COMPATIBILITY GUIDE

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

3500/15 Power Supply. Description

3500 Internal Barriers Product Datasheet Bently Nevada* Asset Condition Monitoring

Description. Improved Startup/Shutdown Data Collection: New Ethernet Link to Data Manager* 2000 computers. View Transient Plots during machine SU/SD

3500/23E Transient Data Interface

3500/65 16-Channel Temperature Monitor

3500/92 Communication Gateway

Vibration Transducer Interface

3500/23E Transient Data Interface

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

1701/05 FieldMonitor* Terminal Base Bently Nevada* Asset Condition Monitoring

Specifications. Inputs. Outputs. Recip Velocity. Signal. Front Panel LEDs OK LED. Input Impedance TX/RX LED. Sensor Compatibility.

Installation Instructions

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Process Current Output 3B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Bently Nevada 60M100 Monitor Bently Nevada* Asset Condition Monitoring

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Process Current Input with Loop Power 7B35

Isolated Current Output 5B39 FEATURES APPLICATIONS PRODUCT OVERVIEW

3500 Monitoring System Rack Installation and Maintenance Manual

3500/95 System Integrated PC Display Bently Nevada* Asset Condition Monitoring

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Valve and Case Expansion Monitor Specifications

Shown with terminal block Supports diagnostic point fault contacts in the logic program

OX 5022-CK OX 5042-CK

EOS-6000 Series Optical A/B Switch User Manual DC Version

Protection Cards for AMS 6500 Classic Systems

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA SST7000 SST7100. Speed Switch / Transmitter

Part Number Revision B, January /91 EGD Comm Gateway Module User's Guide

9200, Seismoprobe* Velocity Transducers

Velomitor* CT Velocity Transducer

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Comm. RS-232. Analog I/O I N P U T S O U T P U T S. I/O Supply. Logic Supply RET RET Fault

ALS c en Alspa CE80 20 N80 Bus Interface Unit User s Manual

KOLLMORGEN. SERVOSTAR CD. SERCOS IDN Manual M-SS rev. F. Solutions by D A N A H E R M O T I O N

3500 System Overview. Description

Distributed Power System SA3100 Drive Configuration and Programming

mm and 8 mm PROXIMITY TRANSDUCER SYSTEM

V E1B Snap-in I/O Module

Allen-Bradley. User Manual. PLC-5 Backup Communication Module (1785-BCM, 1785-BEM) product icon

Digital ac/dc (24V) Input Module

GV3000/SE 230 VAC 1-20 HP General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.04

Resolver to Digital Expansion Board

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

and High Temperature Velomitor * System

Read this chapter to familiarize yourself with this manual. It tells you how to use the manual properly and efficiently.

LiquiFlo AC General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.4

9200, Seismoprobe

Velomitor * Piezo-velocity Sensor

PACSystems* RX3i IC694ALG233

GV3000/SE General Purpose (Volts/Hertz) and Vector Duty AC Drive, HP, 230V AC

PACSystems* RX3i and Series 90*-30 IC694ALG442-CC and IC693ALG442-EC

PACSystems* RX3i IC694ALG232

Description. Specifications

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

V E2B Snap-in I/O Module

Model 7705 Control Module

USER S MANUAL. C11S- MULTIFUNTCION CNC BOARD Rev. 1.2

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

USER MANUAL. MODEL 552 Series. High Speed Telco Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

991 Thrust Transmitter Bently Nevada* Asset Condition Monitoring

Installation Instructions

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor.

Installation Instructions

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

Isolated, Voltage or Current Input 7B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Throughout this manual we use notes to make you aware of safety considerations:

I/O SIGNAL CONDITIONER

AMCI NX3A1E Specifications Rev 0.0 Resolver PLS Ethernet Module

Installation Instructions

Installation Instructions

Firmware Version 1.xx

2300 Vibration Monitors

SmartFan Fusion-4. Speed Control and Alarm for DC Fans CONTROL RESOURCES INCORPORATED. The driving force of motor control & electronics cooling.

User s Manual Pulse Encoder Interface Module OTAC-01

PCI 2 Axis Servo Card

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

Installation Instructions

Transcription:

Operation and Maintenance Manual Bently Nevada Asset Condition Monitoring 3500/25 Enhanced Keyphasor Module Part Number 129770-01 Rev. N (03/08)

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual Copyright 1995. Bently Nevada LLC. All rights reserved. The information contained in this document is subject to change without notice. The following are trademarks of General Electric Company in the United States and other countries: Bently Nevada, Keyphasor, and Proximitor The following are trademarks of the legal entities cited: 3M and Velostat are trademarks of 3M Company. Contact Information The following contact information is provided for those times when you cannot contact your local representative: Mailing Address 1631 Bently Parkway South Minden, Nevada USA 89423 USA Telephone 1.775.782.3611 1.800.227.5514 Fax 1.775.215.2873 Internet www.ge-energy.com/bently ii

Additional Information Notice: This manual does not contain all the information required to operate and maintain the product. Refer to the following manuals for other required information. 3500 Monitoring System Rack Installation and Maintenance Manual (129766-01) general description of a standard system general description of a Triple Modular redundant (TMR) system instructions for installing and removing the module from a 3500 Rack 3500 Monitoring System Rack Configuration and Utilities Guide (129777-01) guidelines for using the 3500 Rack Configuration software for setting the operating parameters of the module guidelines for using the 3500 test utilities to verify that the input and output terminals on the module are operating properly 3500 Monitoring System Computer Hardware and Software Manual (128158-01) instructions for connecting the rack to 3500 host computer procedures for verifying communication procedures for installing software guidelines for using Data Acquisition / DDE Server and Operator Display Software procedures and diagrams for setting up network and remote communications 3500 Field Wiring Diagram Package (130432-01) diagrams that show how to hook up a particular transducer lists of recommended wiring Product Disposal Statement Customers and third parties, who are not member states of the European Union, who are in control of the product at the end of its life or at the end of its use, are solely responsible for the proper disposal of the product. No person, firm, corporation, association or agency that is in control of product shall dispose of it in a manner that is in violation of any applicable federal, state, local or international law. Bently Nevada LLC is not responsible for the disposal of the product at the end of its life or at the end of its use. iii

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual Contents 1. Receiving and Handling Instructions...1 1.1 Receiving Inspection... 1 1.2 Handling and Storage Considerations... 1 2. General Information...3 2.1 Module Compatibility... 4 2.2 Expanded Signal Processing Capability... 4 2.3 Paired Keyphasor Signal Capability... 5 2.3.1 Overview... 5 2.3.2 Conditions for Selecting the Output Signal... 6 2.3.3 Special Considerations... 7 2.4 Triple Modular Redundant (TMR) Description... 7 2.5 Available Data... 8 2.5.1 Module Statuses... 8 2.5.2 Channel Status... 9 2.6 LED Descriptions...10 3. Configuration Information...11 3.1 Hardware Considerations...11 3.1.1 General...11 3.1.2 Paired Keyphasor Signal Hardware Restrictions...11 3.2 Software Configuration Considerations...12 3.2.1 Keyphasor Module/3500 Monitor Configuration Interaction...12 3.2.2 Signal Paths and Signal Options...12 3.2.3 Event Setup Options...13 3.2.4 Keyphasor Signal Rate Division by 3500 Monitors...13 3.2.5 Restriction On Availability of Absolute Phase Information...14 3.2.6 Phase Accuracy Limitation of Processed Signals...14 3.2.7 Limitations When Specifying an Events Ratio Setup...15 3.3 Software Configuration Options...17 3.3.1 Keyphasor Module Configuration Options...17 3.3.2 Keyphasor Module Configuration Screen Examples...24 3.3.3 Paired Keyphasor Signal Configuration...28 3.3.4 Paired Keyphasor Signal Configuration Screen Examples...29 3.3.5 Software Switches...30 3.3.6 Software Switch Options...31 iv

4. Keyphasor I/O Module Descriptions... 33 4.1 Internal Termination Keyphasor I/O Modules...34 4.1.1 Non-Isolated Internal Termination Keyphasor I/O Module...34 4.1.2 Isolated Internal Termination Keyphasor I/O Module...35 4.1.3 Internal Barrier Internal Termination Keyphasor I/O Module...36 4.1.4 Euro Style Connectors...36 4.2 External Termination Keyphasor I/O Modules...37 4.2.1 Non-Isolated External Termination Keyphasor I/O Module...38 4.2.2 Isolated External Termination Keyphasor I/O Module...38 4.2.3 External Termination Blocks...40 4.2.4 External Termination Block Cable Signal Pinouts...41 5. Maintenance... 43 5.1 Verifying Keyphasor Module Operation...43 5.1.1 Choosing a Maintenance Interval...43 5.1.2 Required Verification Test Equipment...43 5.1.3 Typical Verification Test Setup...44 5.1.4 Using 3500 Rack Configuration Software For Verification Testing...45 5.1.5 Procedure For Verifying Keyphasor Module Channels...46 5.1.6 If a Channel Fails a Verification Test...51 5.2 Replacing or Upgrading Firmware...51 5.2.1 Determine The Firmware Replacement Process To Use...52 5.2.2 Replace the Firmware IC...52 5.2.3 Firmware Download Via Rack Configuration Software...56 6. Troubleshooting... 59 6.1 Self-Test...59 6.2 LED States...59 6.3 System Event List Messages...60 6.3.1 List of System Event Messages...61 6.4 Alarm Event List Messages...71 7. Ordering Information... 73 7.1 List Of Options and Part Numbers...73 7.1.1 Enhanced Keyphasor Module...73 7.1.2 Keyphasor Signal (KPH) to External Termination Block (ET) Cable...74 7.2 Spares...74 8. Specifications... 77 8.1 Inputs...77 8.2 Signal Conditioning...77 v

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual 8.3 Signal Processing...79 8.4 Transducer Conditioning...80 8.5 Outputs...80 8.6 Environmental Limits...81 8.7 CE Mark Directives...81 8.7.1 EMC Directives...81 8.7.2 Low Voltage Directives...82 8.8 Hazardous Area Approvals...82 8.9 Physical...82 8.9.1 Main Module...82 8.9.2 I/O Modules Except Internal Barrier I/O Module...83 8.9.3 Internal Barrier I/O Module...83 8.10 Rack Space Requirements...83 vi

Section 1 - Receiving and Handling Instructions 1. Receiving and Handling Instructions 1.1 Receiving Inspection Visually inspect the module for obvious shipping damage. If shipping damage is apparent, file a claim with the carrier and submit a copy to Bently Nevada LLC. 1.2 Handling and Storage Considerations Circuit boards contain devices that are susceptible to damage when exposed to electrostatic charges. Damage caused by obvious mishandling of the board will void the warranty. To avoid damage, observe the following precautions in the order given. Application Advisory Machinery protection may be lost when you remove this module from the rack. Do not discharge static electricity onto the circuit board. Avoid tools or procedures that would subject the circuit board to static damage. Some possible causes include ungrounded soldering irons, nonconductive plastics, and similar materials. Personnel must be grounded with a suitable grounding strap (such as 3M Velostat No. 2060) before handling or maintaining a printed circuit board. Transport and store circuit boards in electrically conductive bags or foil. Use extra caution during dry weather. Relative humidity less than 30% tends to multiply the accumulation of static charges on any surface. 1

Section 2 - General Information 2. General Information The 3500/25 Enhanced Keyphasor Module is a half-height, 2-channel module that provides Keyphasor signals to the Monitor modules in a 3500 Rack. The Keyphasor module receives analog input signals from proximity probes or magnetic pickups and converts them to conditioned digital signals that indicate when the Keyphasor mark on the shaft is in line with the probe. The 3500 Monitoring System can accept 4 such Keyphasor signals, which the 3500 Monitoring System modules and external diagnostic equipment use to measure such vector parameters as 1X amplitude and phase. A 3500 Rack may have 1 or 2 Keyphasor Main Modules in a normal configuration, 3 or 4 Keyphasor Main Modules for a paired Keyphasor configuration, and 1 of 5 types of Keyphasor I/O Modules installed. 1. Keyphasor Main Module (front panel buffered output connectors indicated) 2. Keyphasor I/O Module, with Isolated Internal Terminations 3. Keyphasor I/O Module, with Isolated External Terminations 4. Keyphasor I/O Module, with Non-Isolated Internal Terminations 5. Keyphasor I/O Module, with Non-Isolated External Terminations 6. Keyphasor I/O Module, with Barriers (Non-Isolated, Internal Terminations) Figure 2-1: Views of the Keyphasor Main Module and Keyphasor I/O Module Components 3

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual 2.1 Module Compatibility The 3500/25 Enhanced Keyphasor Main Module is an upgraded version of the original 3500/25 Keyphasor Main Module. It offers enhanced signal processing capabilities and remains completely compatibility with the original Keyphasor Main Module and all Keyphasor I/O Modules for use in legacy systems. The form, fit and function of the 2 Keyphasor modules are essentially identical, as the new module incorporates the additional enhanced features incorporated into its internal design. You can access the enhanced features with upgraded Rack Configuration software. Throughout this manual, the term "Keyphasor Module" refers interchangeably to both the original Keyphasor Main Module (PWA 125792-01) and the Enhanced Keyphasor Main Module (PWA 149369-01). The physical and mechanical characteristics of these 2 main modules, including product labeling, are identical. The interface to the 3500 Rack remains unchanged. Each of the various Keyphasor I/O Modules also remains unchanged. This manual uses the full name, "Enhanced Keyphasor Module", in those circumstances in which it references the unique, enhanced signal processing capability of the new module. 2.2 Expanded Signal Processing Capability The Enhanced Keyphasor Module uses a digital signal processor (DSP) to expand on the original Keyphasor module design. This processor optionally generates an arbitrary number of output Keyphasor events in proportion to the number of input events. The generated output rate may be greater than or less than the input rate and is not limited to a small range of integral event ratios. You can independently program virtually any practical real-numbered ratio of input events to output events for each of 2 signal channels. 2 types of Keyphasor signals are available from an Enhanced Keyphasor Module. You may select these on a per-channel basis, and further select them individually for routing to the Monitor modules in a 3500 Rack and to the buffered outputs. The 2 types are referred to as "Processed" and "Non-Processed" signals. Processed signals are signals that undergo a change in frequency from the input transducer signal to the output conditioned Keyphasor signal. This type of signal is only available from an Enhanced Keyphasor Module, and is only available for certain configuration options as detailed in Section 3. Non-Processed signals are signals that do not undergo a change in frequency from the input transducer signal to the output conditioned Keyphasor signal. This is the only type of signal that the original Keyphasor Module design produced. 4

Section 2 - General Information 2.3 Paired Keyphasor Signal Capability 2.3.1 Overview Revision C and newer Keyphasor Modules (P/N 149369-01) have additional circuitry that previous revisions did not include. This circuitry provides you with Paired Keyphasor Signal capability. Paired Keyphasor Signal Capability is intended for customers who have speed input sets that they wish to use as a primary and a backup speed signal entering the Keyphasor Module. The Keyphasor Module then determines which signal in each set that it will transmit down the backplane and pass to monitors in the 3500 rack. Each Keyphasor module will transmit only 1 of its 2 input signals to the rest of the 3500 system. Note that, although the Keyphasor module will output only 1 signal to the 3500 system, it will continuously monitor both channels. In a Paired Keyphasor Signal application, you can insert 4 half-height Keyphasor modules, which will allow up to 8 Keyphasor input signals at one time. You can place the 4 Keyphasor modules anywhere in the rack except in the slots designated for the RIM and the Power Supplies. You must place the Keyphasor modules in adjacent slots with 2 modules in the upper half and 2 modules in the bottom half of the rack. The 3500 system backplane can accept only 4 speed input signals. Therefore, during Paired Keyphasor signal operation, each of the 4 Keyphasor modules will drive one backplane trace with 1 of the 2 input signals it receives. The module configuration and the status of each Keyphasor channel determine the signal that each module places on the backplane. The Keyphasor module must avoid conflicts and contention on the 4 system Keyphasor signal lines when it switches from primary to the backup input signals. To accomplish this, the Keyphasor module first tests the system line to see if another module is driving the line before actively driving the line itself. The Keyphasor module will test for conflicts on power up or whenever it switches Keyphasor signals. If the Keyphasor module detects a backplane drive conflict, the module behavior will be consistent with reporting a fatal error (e.g., upon detection of an invalid configuration or fatal node voltage error). This will disable the primary function and rendering the Module OK status as Not OK. For cases in which invalid module configurations, rather than hardware malfunctions, cause this to occur, you can correct the problem by downloading valid configuration(s) to the 3500 module(s) in the rack that are creating or being affected by this condition. For cases in which a hardware failure is the cause of the problem, replacing the offending module(s) and then downloading a valid configuration to the 3500 rack should resolve the problem. 5

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual 2.3.2 Conditions for Selecting the Output Signal To determine which input signal a Keyphasor module will transmit to the 3500 system during Paired Keyphasor Signal operation, the following conditions apply: 1. If an input channel is Not Active, the module will consider the channel to be non-existent, so it cannot source the output. 2. If an input channel is in Bypass, the module can consider it to be temporarily non-existent while Bypass is active, so it cannot source the output. Note that Threshold Adjust mode overrides Bypass so that a channel will act as though it is not in Bypass. Only one channel at a time can be in Threshold Adjust mode. 3. If the Primary input channel is Active and not in Bypass, and its OK state is Valid, the Primary input channel will source the output, OR If the Primary input channel is Active and not in Bypass, and the Backup input channel is either Not Active or is in Bypass, the Primary input channel will source the output. 4. If the Backup input channel is Active and not in Bypass, and the Primary input is not sourcing per Condition 3, then the Backup input channel will source the output. 5. If the module is using neither the primary nor the backup input signals to drive the system Keyphasor lines, then the module will not drive the output (i.e., the module will place the line in a high impedance (High-Z) state). Table 2-1 summarizes which output the Keyphasor module will send to the system for the various possible circumstances: Table 2-1: Paired Keyphasor Signal Output Summary (X = Don t Care) Case Primary Active Primary Threshold Adjust Primary Bypass Primary Valid Backup Active Backup Threshold Adjust Backup Bypass Backup Valid Output Channel 1 No X X X No X X X High-Z 2 No X X X Yes No No X Backup 3 No X X X Yes Yes X X Backup 4 No X X X Yes No Yes X High-Z 5 Yes No Yes X No X X X High-Z 6 Yes No Yes X Yes No No X Backup 7 Yes No Yes X Yes Yes X X Backup 8 Yes No Yes X Yes No Yes X High-Z 9 Yes Yes X Yes X X X X Primary 6

Section 2 - General Information Case Primary Active Primary Threshold Adjust Primary Primary Backup Bypass Valid Active Backup Threshold Adjust Backup Backup Output Bypass Valid Channel 10 Yes Yes X No No X X X Primary 11 Yes Yes X No Yes No No X Backup 12 Yes Yes X No Yes No Yes X Primary 13 Yes No No Yes X X X X Primary 14 Yes No No No No X X X Primary 15 Yes No No No Yes No No X Backup 16 Yes No No No Yes Yes X X Backup 17 Yes No No No Yes No Yes X Primary 2.3.3 Special Considerations You should consider the following special factors when using the Paired Keyphasor Signal Capability: Following a transition from a Primary to Backup (or Backup to Primary) Keyphasor signal, there will be a period in which the Keyphasor signal is likely to be invalid on the system line that is being switched. Because the Primary and the Backup signals may closely resemble each other, it is possible that a 3500 monitor will not detect a switch from Primary or that the phase has potentially become invalid. Unless both the Primary and Backup signal sources can provide absolute phase information, the 3500 system cannot guarantee the validity of the phase information from a given Primary/Backup signal pair. Because the 3500 monitors cannot always detect when Keyphasor signals switch, we have created System Event numbers 494 through 496 to inform you that these switches have occurred. 2.4 Triple Modular Redundant (TMR) Description When TMR applications require a system Keyphasor signal input, you should equip the 3500 with 2 Keyphasor Modules. In a TMR application, the modules work in parallel to provide both a primary and secondary Keyphasor signal to the other modules in the rack. When used in a TMR application, you may connect Keyphasor transducers to the 3500 Rack in 2 ways. 1. Redundant Keyphasor Transducers. Each measurement location has 2 independent Keyphasor transducers. This configuration provides for both primary and secondary inputs and is the most fault tolerant and reliable configuration. In this configuration, the primary and secondary inputs will connect to independent Keyphasor Modules. 7

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual 2. Single Keyphasor Transducers. This configuration requires only a single Keyphasor transducer. The signal from this transducer is wired to provide input to both Keyphasor Modules. TMR applications can support only 2 speed measurement locations. 2.5 Available Data The Keyphasor Module returns the machine speed in RPM, measured from each Keyphasor transducer. The RPM reading is the primary value and that the Communication Gateway Module and the Rack Interface Module use. The Keyphasor Module also returns both module and channel statuses. The following sections describe the statuses and where you can find them. 2.5.1 Module Statuses 2.5.1.1 OK Status This indicates if the Keyphasor Module is functioning correctly. A module returns a Not OK status under any of the following conditions: Node Voltage Failure Hardware Failure in the module Configuration Failure Slot ID Failure If the Module OK status goes Not OK, then the module will drive the system OK Relay on the Rack Interface I/O Module Not OK. 2.5.1.2 Configuration Fault Status This indicates if the Keyphasor Module configuration is invalid. 2.5.1.3 Bypass Status This indicates if the Keyphasor Module has been bypassed. Any of the following conditions can bypass the Keyphasor Module: Keyphasor Module has never been configured Keyphasor Module is in configuration mode Module found a fatal error during self-test A channel has an invalid configuration Any active channel is bypassed 8

2.5.1.4 Module Status Locations Section 2 - General Information Table 2-2 shows the location of the module statuses. Table 2-2: Module Status Locations Module Statuses Communication Gateway Module Rack Configuration Software Operator Display Software OK X X Configuration Fault Bypass 2.5.2 Channel Status 2.5.2.1 OK Status This indicates whether or not the module has detected a fault on the channel. The following will cause a Channel Not OK status AND a Module Not OK status: Node Voltage Failure Hardware Failure in the module Bypass is active on the channel Configuration Failure Slot ID Failure The following will cause only a Channel Not OK status and will NOT cause module to drive the System OK Relay on the Rack Interface I/O Module: 2.5.2.2 Bypass Status Keyphasor Signal less than 1 RPM Keyphasor Signal greater than 99,999 RPM Keyphasor Signal has a 50% or greater Change in Period Keyphasor Transducer Failure Keyphasor Signal greater than 20 khz This indicates if the associated Keyphasor Module channel has been bypassed. Any of the following conditions can bypass a channel: Keyphasor Module has never been configured Keyphasor Module is in configuration mode Module found a fatal error during self-test X X 9

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual 2.5.2.3 Off Status A channel has an invalid configuration Any active channel is bypassed This indicates whether the channel has been turned off. You may use the Rack Configuration Software to turn off the Keyphasor channels. 2.5.2.4 Channel Status Locations Table 2-3 shows the locations of the channel statuses. Table 2-3: Channel Status Locations Channel Statuses Communication Gateway Module Rack Configuration Software Operator Display Software OK X X X Bypass X X X Off X X 2.6 LED Descriptions The LEDs on the front panel of the Keyphasor Module indicate the operating status of the module as shown in Figure 2-2. Refer to Section 6.2 for all of the available LED conditions. 1. OK LED: Indicates that the Keyphasor Module and the Keyphasor I/O Module are operating correctly. 2. TX/RX LED: Indicates communication between the Keyphasor Module and the Rack Interface Module as messages are transmitted and received. Figure 2-2: Keyphasor Module Front Panel LEDs 10

Section 3 - Configuration Information 3. Configuration Information This section describes how to use the Rack Configuration Software to configure the 3500/25 Keyphasor Module. It also describes the configuration restrictions that are associated with this module. Refer to the 3500 Monitoring System Rack Configuration and Utilities Guide and the Rack Configuration Software for details on how to use the software. 3.1 Hardware Considerations 3.1.1 General The slots in the rack are numbered from 0 to 15, counting from left to right. The power supplies go into slot 0 and the Rack Interface Module goes into slot 1. Slots 2 through 15 are called monitoring positions. You can install the 3500/25 Keyphasor Module into any of the monitoring positions. However, if you will use the 3500/20 Rack Interface Module and Data Manager I/O to interface to the DDIX, TDIX, or TDXnet, refer to the manual on the 3500/20 for details on the slot restrictions that this may place on your configuration. 3.1.2 Paired Keyphasor Signal Hardware Restrictions In a paired Keyphasor signal application you can insert up to 4 half height Keyphasor Modules which would support up to 8 Keyphasor Module input signals at one time. You can place the 4 Keyphasor Modules in any slot in the rack except those slots designated for the RIM and the Power Supplies. You must, however, place the Keyphasor Modules in adjacent slots with 2 modules in the top half and 2 modules in the bottom half of the rack. Application Advisory When using the 3500/25 in a Paired Keyphasor Signal application, your system must have the following or more recent modules and firmware: Management 4 Channel Monitors (PWA 140734-XX): Firmware Rev. 2.30 3500/22 Transient Data Interface (PWA 1388607-XX): Firmware Rev. 1.20 11

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual 3.2 Software Configuration Considerations Although most of the Keyphasor Module configuration options are very straightforward, the increased signal processing options warrant a discussion of some configuration considerations that you should know. This section covers those considerations and introduces some new terms that the Enhanced Keyphasor Module configuration uses. 3.2.1 Keyphasor Module/3500 Monitor Configuration Interaction The Keyphasor probe orientation and Event Setup configuration parameters are directly linked to monitor operation in the 3500 Rack. When these parameters change, you must download (or re-download) to the 3500 rack the configuration of the monitors that are associated with the changed Keyphasor channels. The Rack Configuration Software displays messages and confirmation dialog boxes to help you properly select the affected monitors to which you should download configuration as appropriate. 3.2.2 Signal Paths and Signal Options There is an important distinction between the Rack Signal and Buffered Output signal paths, and the selection of Processed and Non-Processed signals that one wishes to place on them. These terms are defined here. The Rack Signal path is the Keyphasor signal path that runs down the 3500 System Backplane, for use by monitors in the rack. The Buffered Output path is the Keyphasor signal path that runs to the front panel BNC connectors and to the Keyphasor I/O Module Buffered Output terminals. Note that the Buffered Output signal paths have no bearing on how monitors in the rack handle Keyphasor signals, as the monitors do not operate on the Buffered Output signals. The selection of the signal type put on the Rack Signal path does, however, affect monitor operation as this manual describes. Non-Processed signals are simply those signals that have not undergone a change in frequency, from the input transducer signal to the output conditioned signal. Processed signals are those signals that have undergone a change in frequency. Processed signals may be at a rate that is higher or lower in frequency than the input transducer signal from which they are derived. The following example can illustrate the effect of using Processed vs. Non- Processed signals: 12

Section 3 - Configuration Information Suppose that you apply identical, 100 RPM test signals to the inputs of 2 Enhanced Keyphasor Module channels. If you specify the Event Ratio for Channel 1 to be 0.5 and the Event Ratio for Channel 2 to be 2.0, then the Processed signal output on Channel 1 would be at 200 RPM, the Processed signal output for Channel 2 would be at 50 RPM, and the Non-Processed signal on either channel, if selected, would be at 100 RPM. The Keyphasor signals that the original Keyphasor Module generates are always of the Non-Processed type. The Enhanced Keyphasor Module can produce both Non-Processed and Processed signals. 3.2.3 Event Setup Options The expanded signal processing capabilities of the Enhanced Keyphasor Module introduces a new configuration parameter known as the Event Setup. This parameter adds the Event Ratio option to the pre-existing Events per Revolution (Events Per Rev) and Recip Multi-Event Wheel configuration options. These 3 options are mutually exclusive and variations of the same theme, as each describes a number of input events seen by the Keyphasor probe relative to a single revolution of some primary rotor. 1. Recip Multi-Event Wheel. This is the most specialized option, and has a fixed value of 13 input events per single rotation of the primary rotor. This option is intended for reciprocating (or recip) machine applications. 2. Events Per Rev. This option allows you to specify 1 to 255 input Keyphasor events per single revolution of some primary rotor. 3. Event Ratio. This option is the most flexible option. It allows you to specify a practically unlimited range for the number of input Keyphasor events per single revolution of some primary rotor (or, more generally, the ratio of the number of input events per generated output events), including fractional numbers. Processed signals are generally synonymous with an Event Ratio Event setup, whereas Non-Processed signals usually imply an Events Per Rev or Recip Multi-Event Wheel Event Setup. To eliminate redundant specifications of any particular configuration, the Rack Configuration Software automatically reduces an Event Ratio Event Setup to an Events Per Rev Event Setup whenever they would be logically equivalent. 3.2.4 Keyphasor Signal Rate Division by 3500 Monitors Individual monitors in a 3500 Rack are sensitive to the configuration for Non- Processed Rack Signals in which you specify the Event Setup parameter to be an integer in the range of 2 to 255. It makes no difference whether you option the Event Setup as Events Per Rev, Event Ratio or Recip Multi-Event Wheel. For this particular configuration, the individual monitors that are configured to use such a 13

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual Keyphasor channel will internally divide the rate of the received Keyphasor pulse train at the individual monitor level. Simply put, individual monitors divide down the Keyphasor signal they receive from the rack signal path by the integer value in the Event Setup numeric input field on the Keyphasor Module configuration screen. Note that in all cases for which you configure a Keyphasor channel to use a Processed Rack Signal, monitors in the rack that are configured to use that channel will not internally divide the Keyphasor signal rate. This makes sense since the point of using a Processed Rack Signal is to let the Enhanced Keyphasor Module do the work of modifying the incoming signal rate to provide monitors with a "once-per-turn" Keyphasor signal. 3.2.5 Restriction On Availability of Absolute Phase Information One caution of which you should be aware is that absolute phase information is not available from a monitor channel that uses a Processed Rack Signal, or when the specified Events Per Rev value is other than 1. This is because after the module loses or invalidates a Keyphasor input signal, the re-acquired input signal may or may not correspond with the synchronizing events of past or future sessions from run to run. To illustrate this, consider that if your system uses an n-tooth gear as the input Keyphasor source, then from run to run the Keyphasor module cannot guarantee that it will observe any specific gear tooth or notch as the "synchronizing event" during the re-synchronization process. So for this reason, the monitor disables phase information (makes the information unavailable and/or marks the information as invalid) when using a Processed Rack Signal, or if the specified Events Per Rev Event value is other than 1. The Recip Multi-Event Wheel option is a special case however, and the system retains phase information with this setup. The Rack Configuration Software displays messages and confirmation dialog boxes to assist you with properly identifying and selecting monitors that would be affected by this constraint. 3.2.6 Phase Accuracy Limitation of Processed Signals As with any processed signal system, the finite response time limits the precision and accuracy of the generated output Processed Keyphasor signal in response to the input signal. Users of processed signal systems should consider both static and dynamic phase error components, however small they may be. The following discussion covers the phase error specifications for static and dynamic Processed output signals. The Specifications section of this manual contains more detailed information regarding the Static and Dynamic Phase Error characteristics of the Enhanced Keyphasor Module when generating Processed signals. 14

3.2.6.1 Static Phase Error Section 3 - Configuration Information The Static Phase Error ("SPE") of the Processed output signal is the long-term deviation in the output signal that occurs when the system maintains a constant-speed input signal. This deviation is due to unavoidable deviation in algorithm execution time for the DSP to process asynchronous Keyphasor input events, and is limited by the internal DSP clock rate. The Enhanced Keyphasor Module exhibits approximately ±6 µs of fixed, maximum deviation in the output signal over time. Table 3-1 shows some representative performance numbers for Static Phase Error values that you may expect for typical output frequencies across the valid range. Note that as the output frequency decreases the worstcase SPE also decreases in a linear fashion. Table 3-1: Representative Static Phase Error (SPE) Values 3.2.6.2 Dynamic Phase Error Fout (Hz) RPM/CPM SPE 1667 100,000 ±3.60 463 27,780 ±1.00 60 3600 ±0.13 50 3000 ±0.11 The Dynamic Phase Error ("DPE") of the Processed output signal is the short-term deviation in the output signal that results from a changing-speed input signal. This deviation is due to several factors. 1. The signal processing algorithms have an unavoidable natural response latency, due mostly to the DSP s finite internal clock rate. 2. The Enhanced Keyphasor Module s algorithms are predictive in nature. This tends to improve the response for frequency division (Event Ratio is greater than or equal to 2.0) and degrade the response for frequency multiplication (Event Ratio is less than 2.0). The Event Ratio strongly affects the dynamic response in a non-linear, natural logarithmic fashion. 3. The Enhanced Keyphasor Module exhibits an essentially linear change in the degrees of phase error per percent change, assuming constant acceleration. 3.2.7 Limitations When Specifying an Events Ratio Setup The 3500 Configuration Software displays the numeric range to the left of the data entry field for the Event Setup of an Event Ratio as 0.0000001 to 10000000.0. This reflects the valid range of numbers that you may specify for the Event Ratio. This range, for all intents and purposes, should cover any practical user application. Note that the Rack Configuration software automatically performs limit checking to ensure that you enter only numbers within the valid range. 15

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual Regardless of the Event Ratio you specify, both the input Keyphasor signal and generated Processed Rack Signals have limitations that, among other things, affect the Channel and Module OK Statuses. The Specification section of this manual details these limitations. 16 You may specify the Event Ratio as a positive, real number (i.e., an integer and/or fractional number) that is either less than or greater than, but not exactly equal to, 1.0. Although the software will not allow you to specify an Event Ratio of exactly 1.0, you can functionally achieve this by specifying the Events Per Rev with a value of 1 with the Event Setup option. This configuration supports the majority of typical customer applications and achieves maximum system performance. This also eliminates what would otherwise be a redundant means of specifying unity Keyphasor rate processing. Noted that, in general, the system is better able to track the input for higher Event Ratio numeric values, since it has more "information" in the form or input pulses with which to work. This allows the system to better to respond to speed fluctuations or ramping conditions as it tracks the input. There are a few extra considerations to remember when you specify an Event Ratio less than 2.0. The design of the digital signal processing algorithm uses 2 fundamentally different strategies, one for Event Ratios equal to or greater than 2.0 (which essentially implies frequency division), and the other for Event Ratios less than 2.0 (which implies frequency multiplication). The DSP code automatically selects the algorithm based on the programmed Event Ratio for each channel. The large majority of applications will require the Keyphasor module to use an Event Ration much greater than 2.0 to divide down the input signal. Because of this the DSP code has been optimized to support these applications. This improves the module s transient response for frequency division, but degrades the response for frequency multiplication. For this reason, you should not expect the Enhanced Keyphasor Module to exhibit any reasonable transient response for Event Ratios approaching or less than 2.0. Frequency multiplication processing has 2 additional side effects that are not present when you specify an Event Ratio of 2.0 or greater. These 2 side-effects are similar in effect and result from the limitations that are inherent in attempting to generate multiple output pulses in response to a single input pulse (or sequence of pulses), which is the essence of frequency multiplication. 1. The Enhanced Keyphasor Module may require a significant amount of synchronization time from when a signal is first applied to the input to a Keyphasor channel to when the first Processed Signal output appears. Generally speaking, the more significant digits you specify to the right of the decimal point in the Event Ratio, the longer the DSP may take to synchronize to the input and generate output pulses in response. 2. When the Enhanced Keyphasor Module loses the input Keyphasor signal, a multiplied output at the programmed rate may persist for some time after the input stimulus is lost.

Section 3 - Configuration Information These side effects may persist for 2 minutes or more. 3.3 Software Configuration Options This section discussed the Keyphasor Module configuration options in detail. In addition to describing the options, this section provides figures that depict screen views of the 3500 Rack Configuration software. Several examples illustrate the various option choices on the Keyphasor Module configuration screen. Depending on the numeric values entered for some configuration parameters, the Rack Configuration Software may restrict certain options, make options unavailable, and/or automatically "force-select" some options. 3.3.1 Keyphasor Module Configuration Options Figure 3-1: Keyphasor Module Configuration Screen 3.3.1.1 REFERENCE INFORMATION These fields are shown at the top of the Configuration Screen and contain information that indicate the location of the Keyphasor Module in the 3500 Rack, the type of associated Keyphasor I/O Module, and an optional label for you to track configuration setups. Note that you must select the I/O Module parameter as part of the configuration setup. 17

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual ConfigID Slot This information field displays an optional identifier of up to six characters, which if present was entered upon last configuration download to the module. This information field indicates the slot monitoring position of the Keyphasor Module in the 3500 Rack. Keyphasor Position This information field identifies where the Keyphasor Module is physically located in the 3500 Rack, either in the Upper or Lower slot. I/O Module This user-input field specifies the type of interface module used to connect the transducers to the Keyphasor Main Module. Internal and External Termination options refer to the wiring points of the transducers, which either wire directly to the I/O module (Internal type) or to an external termination block (External type). The Barrier I/O type is offered only as an Internal Termination type, and does not support the Magnetic Pickup transducer type option. The Isolated types provide transformer isolation of the input channels from the rack common and from each other. The available Keyphasor I/O Module options are as follows: Keyphasor I/O Module (Internal Termination) Keyphasor Barrier I/O Keyphasor I/O Module (External Termination) Isolated Keyphasor I/O (Internal Termination) Isolated Keyphasor I/O (External Termination) Output Assignment This option is only available for paired Keyphasor configuration. Since 2 Keyphasor modules (with a total of 4 outputs) must share only 2 outputs, you can configure each paired Keyphasor only in a primary/backup manner, allowing each module only 1 output assignment. For the module, select channel 1 or channel 2 to be this assignment. The user must select this assignment. Input Assignment This option is only available for paired Keyphasor configuration. As described previously, output assignment is restricted to 1 channel only for paired Keyphasor configurations. The two inputs must be defined as primary & 18

Section 3 - Configuration Information backup. The choice is channel 1 = Primary / channel 2 = Backup OR channel 2 = Primary / channel 1 = Backup. The user must select this assignment. 3.3.1.2 CHANNEL CONFIGURATION You may configure the 2 channels of a Keyphasor Module independently of each other, per the following configuration options. The software specifies the Channel 1 options in the left half of the Configuration Screen, below the Reference Information fields. Channel 2 options are specified in the right half. Active (Channel Activity) This check box enables or disables a Keyphasor channel. If you will not connect a Keyphasor transducer to this channel, then you should uncheck this box. Signal Polarity Notch Select the Notch option if the module will use the leading edge of a negative-going pulse in the input signal to produce an output pulse for use by the monitors. A notch in a shaft will cause a Keyphasor transducer to produce this type of input pulse. If you plan to use a magnetic pickup, you should set the Notch/Projection setting to Notch, as in most cases the installation will clip the positive portion of the signal. Projection Select the Projection option if the module will use the leading edge of a positive-going pulse in the input signal to produce an output pulse for use by the monitors. A notch in a shaft will cause a Keyphasor transducer to produce this type of input pulse. Type (Transducer Type) Proximitor Select the Proximitor option if the installation uses a Proximitor or similar type of transducer to supply the Keyphasor signal for this channel. Magnetic Select the Magnetic option if the installation uses a magnetic pickup type of transducer to supply the Keyphasor signal for this channel. Magnetic pickups require a shaft rotative speed of at least 200 RPM (3.3 Hz). Buffered Output The design of the Keyphasor module routes the Buffered Output signal for a given channel to the Keyphasor Module front panel BNC connector and to the Keyphasor I/O Module Buffered Output terminal. 19

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual Non-Processed Select this option if the Buffered Output signal will be "Non-Processed". Processed Rack Signal Select this option if the Buffered Output signal will be "Processed". The 3500 Monitor System design routes the Rack Signal for a given channel down the 3500 System Backplane for use by monitors in the rack. Non-Processed Select this option if the Rack Signal will be "Non-Processed". Processed Hysteresis Select this option if the Rack Signal will be "Processed". Hysteresis is the difference in the input signal between the voltage levels where the Keyphasor pulse turns on and where it turns off. The larger the hysteresis value, the greater the immunity will be to noise on the input signal. See Figure 3-2. 20 Threshold 1. Analog Input Signal 2. Digital Output Keyphasor Signal 3. Threshold 4. Hysteresis Figure 3-2: Example of Signal Hysteresis The value at which the Keyphasor pulse would turn on and off if the Hysteresis was zero. Auto The module automatically sets the trigger threshold to a value midway between the most positive peak and the most negative peak of the input

Section 3 - Configuration Information signal. This threshold option tracks changes in the input signal. Auto threshold requires a minimum signal amplitude of 2 Vpp and a minimum frequency of 120 RPM (2 Hz). Manual Adjust Event Setup You may set the Manual trigger threshold to any value in the range of -20.0 to 0.0 volts. The software makes this option available when you select Manual Threshold. The software displays a dialog box to aid you in setting the Manual Threshold value. Events Per Rev This option specifies the number of pulses in a Keyphasor transducer input signal for each shaft revolution (rotation). If the Keyphasor transducer is observing a single notch or projection, set the Events Per Rev value to 1. If the Keyphasor transducer is observing a multi-tooth gear, set the Events Per Rev value to the number of teeth on the gear. The available range is 1 to 255. Figure 3-3 shows the maximum settings for Events Per Rev. Figure 3-4 and Figure 3-5 depict typical applications. 1. RPM 2. Events Per Revolution 3. Upper RPM Limit is 99999 4. Upper Frequency Limit is 20 khz Figure 3-3: Maximum Events Per Revolution 21

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual Application Advisory You can use signals from a Keyphasor transducer observing a multi-tooth gear (except for Recip Multi-Event Wheel) only for speed measurements and not for phase measurements. 1 2 3 1. Probe A 2. Probe B 3. Shaft with notch Figure 3-4: Events Per Rev Value Typically Set to 1 (Phase Available) 1 2 3 1. Probe A 2. Probe B 3. 24-tooth gear Figure 3-5: Events Per Rev Value Typically Set to 24 (Phase Not Available) 22

Recip Multi-Event Wheel Section 3 - Configuration Information This option is for reciprocating machine applications in which the Keyphasor transducer observes a specially designed 13-tooth gear whose design incorporates a distinguishable once-per-turn event. Event Ratio This option specifies the ratio of the number of input pulses to the number of desired output pulses in a Processed Keyphasor signal. The input pulses are from a Keyphasor transducer observing a shaft or gear. The output pulses are generated by the DSP in an Enhanced Keyphasor Module as the Event Ratio specifies. You can specify the Event Ratio value to be any positive, real number in the range from 0.0000001 to 10000000, other than exactly 1.0. The precision of the Event Ratio can be at least 7 significant decimal digits. The Setup dialog box allows you to specify the Event Ratio in terms of an integer numerator and denominator. Orientation Application Advisory You can use Processed Keyphasor signals that use the Event Ratio Event Setup option only for speed measurements only and not for phase measurements. This option specifies the location of the transducer relative to the shaft. The orientation angle is 0º to 180º left or right as observed from the driver to the driven end of the machine train. The following figure shows this for horizontal shafts. 23

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual 1 2 4 7 5 3 Upper RPM Limit 1. Shaft 6 2. Driven end 3. Driver end 4. 0 degrees 5. 90 degrees right 6. 180 degrees 7. 90 degrees left Figure 3-6: Transducer Orientation On Horizontal Shaft This specifies the full-scale maximum RPM value for the module to use when reporting channel RPM data to the Communication Gateway and Operator Display software. RPM Clamp Value This specifies the fixed RPM value for the Communication Gateway to provide when the channel is Not OK or is bypassed. 3.3.2 Keyphasor Module Configuration Screen Examples This section provides some examples of the Keyphasor Module configuration screen for various configurations. 3.3.2.1 Keyphasor Module Configuration Screen Example 1 Figure 3-7 shows the default "Events Per Rev" Event Setup option, with the Number of Events value set to 1. The Channel 2 configuration is identical to that for Channel 1. 24

Section 3 - Configuration Information Figure 3-7: Default Keyphasor Module Configuration Screen 3.3.2.2 Keyphasor Module Configuration Screen Example 2 Figure 3-8 shows an "Event Ratio" for the Event Setup on Channel 1 and Figure 3-9 shows a "Recip Multi-Event Wheel" for the Event Setup on Channel 2. For Channel 1, the Event Setup allows you to select the Buffered Output as Non- Processed or Processed, which is always the case when you select the Event Ratio Event Setup. The Rack Signal is force-selected as type Processed, since the Event Ratio is non-integer. For Channel 2, the Event Setup forces both the Buffered Output and Rack Signal paths types to be Non-Processed, which is always the case for the Recip Multi-Event Wheel option. Figure 3-8: Keyphasor Module Configuration Screen With Event Ratio Option 25

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual Figure 3-9: Keyphasor Module Configuration Screen With Recip Multi-Event Wheel Option 3.3.2.3 Keyphasor Module Configuration Screen Example 3 Figure 3-10 shows an "Events Per Rev" Event Setup on Channel 1 and Figure 3-11 shows an "Event Ratio" Event Setup on Channel 2. For Channel 1, this Event Setup forces both the Buffered Output and Rack Signal to be Non-Processed, which is always the case for the Events Per Rev option. For Channel 2, you may option both the Buffered Output and Rack Signal for Non- Processed or Processed, since the Event Ratio is an integer in the range 2 to 255 (in this case, 5). Figure 3-10: Keyphasor Module Configuration Screen with Event Per Rev Option 26

Section 3 - Configuration Information Figure 3-11: Keyphasor Module Configuration Screen With Event Ratio Value of 5 3.3.2.4 Keyphasor Module Configuration Screen Example 4 Figure 3-12 specifies an input-multiplying "Event Ratio" Event Setup on Channel 1 and Figure 3-13 an input-dividing "Event Ratio" Event Setup on Channel 2. In both cases, the software forces the Rack Signal to be Processed, since the specified Event Ratio values are not integers. Figure 3-12: Keyphasor Module Configuration Screen With Non-Integer Event Ratio Value Less Than 1 (Input Multiplier) 27

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual Figure 3-13: Keyphasor Module Configuration Screen With Non-Integer Event Ratio Value Greater Than 1 (Input Divider) 3.3.3 Paired Keyphasor Signal Configuration Using the Rack Configuration Software to configuring the 3500/25 module for a Paired Keyphasor application is similar to using the software to configure the module for a Standard application. The following items may help you avoid confusion during the configuration process. Output Assignment refers to the system Keyphasor line that the configured module will drive. There are 4 system lines. In Paired Keyphasor mode you must specify a different Output Assignment for each module. Input Assignment defines the priority of the signals input into the Keyphasor module. This value determines the primary and backup signal within the Keyphasor module you are configuring. The Input Active setting allows you to either enable or disable the monitoring functionality that relates to each channel in the Keyphasor module. You can no longer configure output activity. The output activity in a paired Keyphasor application is based on the Input Assignment, Output Assignment, and the validity, or OK state, of the Keyphasor inputs. When configuring the 3500 Rack configuration Software you should consider the following items: 28

Section 3 - Configuration Information The Rack Configuration Software will not allow you to download a configuration that has more than 2 Keyphasor Modules in the upper or the lower half of the rack. The Rack Configuration Software will not allow you to download a configuration that has a Paired Keyphasor and a Standard Keyphasor configuration in either the upper or the lower half of the rack simultaneously. If you need both Paired Keyphasor and Standard Keyphasor capabilities within a rack, you must use the Paired Keyphasor configuration in the upper/lower half of the rack and the Standard Keyphasor configuration in the opposite half of the rack. The Rack Configuration software will not allow you to use more than 2 slots for Keyphasor modules. If you place 2 Keyphasor modules in the upper half of the 3500 rack and wish to place either 1 or 2 additional Keyphasor modules in the lower half of the rack, you must place the modules in the same slots that have Keyphasor modules in the upper half of the rack. If you associate multiple monitors with 1 paired Keyphasor module, you must configure these monitors to have the same primary and backup Keyphasor association. The 3500 system places restrictions upon Paired Keyphasor applications because the system uses inputs as a primary/backup set for 1 system line. These restrictions require that the 2 Keyphasor inputs have input signals with the same events per revolution or be conditioned to have the same events per revolution before being placed on the system line. To accomplish this, you must configure the Keyphasor modules to ensure one of the following conditions: 1) Both channels will have an input with the same events per revolution and module will process neither channel. 2) The module will process both Channel 1 and Channel 2. 3) The module will process one channel and the other channel will have a 1 event per revolution input. 3.3.4 Paired Keyphasor Signal Configuration Screen Examples To make Paired Keyphasor Signal Capability available, you must place and configure the Keyphasor modules as shown in Figure 3-14. 29

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual Figure 3-14: Paired Keyphasor Signal Configuration Setup After selecting 1 of the 3 configurations (Upper, Lower, or Upper and Lower) shown in Figure 3-14, you can use the options menu to configure each Keyphasor Module. 3.3.5 Software Switches 30 Figure 3-15: Configuring the Keyphasor Module The Keyphasor Module supports software switches that you can use to further control the operation of the module as a whole or on an individual channel basis. These switches let you temporarily bypass, enable or cancel monitor and/or channel functions. You access these switches by selecting Utilities/Software Switches from the main menu screen of the Rack Configuration software.

Section 3 - Configuration Information Figure 3-16: Keyphasor Module Software Switches The following 2 special notes apply to the use of Software Switches. 1. The Software Switch control screen that the Rack Configuration Software shows is common to all the available 3500 System module types. Not all the different types of software switches in this screen apply to the Keyphasor Module. The Keyphasor Module will respond to only the software switch options that this section presents. 2. Software Switch changes do not take effect until you click the Set button. 3.3.6 Software Switch Options 3.3.6.1 Module Switches These switches affect the Keyphasor Module as a whole. The 3500 Monitoring System uses module switch number in the Communication Gateway or Display Interface Module, as shown in Table 3-2. Table 3-2: Module Switch Numbers Module Switch Number Switch Name 1 Configuration Mode 4 Manual Keyphasor Threshold Adjust Mode 31

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual Configuration Mode This switch reflects the Configuration Mode status of the Keyphasor Module. When the Rack Configuration Software downloads a configuration, it will automatically enable and disable this switch. If the software loses its connection to the rack during the configuration process, you can use this switch to remove the module from Configuration Mode. Manual Keyphasor Threshold Adjust Mode This switch reflects the Manual Keyphasor Threshold Adjust Mode status of the Keyphasor Module. If Manual Threshold is selected, the software will automatically enable and disable this switch when you click on the Threshold Adjust button on the Keyphasor Module Configuration Screen. While in this mode, the Keyphasor Module will operate with a temporary Manual Threshold that the Rack Configuration software supplies. Note that monitor values that use the affected Keyphasor signals, such as 1X amplitude and phase, may go invalid while you are adjusting the Manual Threshold value. If the software loses its connection to the rack during the adjustment process, you can use this switch to remove the module from Manual Keyphasor Threshold Adjust Mode. 3.3.6.2 Channel Switches These switches affect the Keyphasor Module on an individual channel basis. The 3500 Monitoring System uses the channel switch number in the Communication Gateway or Display Interface Module, as shown in Table 3-3. Table 3-3: Channel Switch Numbers Channel Switch Number Switch Name 4 Bypass Bypass When you enable this switch, the module will invalidate the RPM value for the channel and bypass the signal conditioning for the channel. 32

Section 4 - Keyphasor I/O Module Descriptions 4. Keyphasor I/O Module Descriptions The Keyphasor I/O Modules are full-height rack modules that receive signals from the Keyphasor transducers and route these signals to the Keyphasor Main Module (or Modules). The I/O Modules provide power to the Keyphasor transducers, and provide conditioned Keyphasor output signals via their Buffered Output terminals. Applications typically use these buffered outputs to provide Keyphasor signals to external equipment, such as TDIX or TDXnet. You may install 1 or 2 Keyphasor Main Modules in the upper and/or lower half of any single "monitoring position" in the rack. For paired signal Keyphasor configuration, the 2 paired Keyphasors must occupy adjacent rack slots. You may install Keyphasors that are configured for paired operation in the upper and lower half-slots of any 2 adjacent monitoring positions in the rack. You then install 1 full-height Keyphasor I/O Module behind this slot (if installed in a Rack Mount or a Panel Mount rack) or above this slot (if installed in a Bulkhead rack). For paired signal Keyphasor configurations you install 2 I/O modules, with 1 module behind or above each slot that contains a Keyphasor Main Module. 5 different types of Keyphasor I/O Modules are available, which cover the various options for internal or external terminations, type of terminations, signal isolation or non-isolation, and use of intrinsic safety barriers or not. Table 4-1 and Table 4-2 summarize the available Keyphasor I/O Module options. Notes: Table 4-1: Internal Termination I/O Module Options I/O Module Options (See Note 1) Non-Isolated Keyphasor I/O Module Isolated Keyphasor I/O Module Internal Barrier Keyphasor I/O Module Table 4-2: External Termination I/O Module Options I/O Module Options (See Note 2) Non-Isolated Keyphasor I/O Module Isolated Keyphasor I/O Module 1. All Internal Termination Keyphasor I/O Modules use Euro Style connectors. 2. All External Termination Keyphasor I/O Modules use an External Termination Block. External Termination Blocks are available with either Euro Style connectors or Terminal Strip connectors. This section of the manual describes how to use the connectors on the various Keyphasor I/O Modules. It also lists part numbers of which cables to use and shows cable signal pin-outs. 33

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual Refer to the following additional documentation for assistance with module wiring and mounting details. The 3500 Field Wiring Diagram Package (part number 130432-01) shows how to connect Keyphasor transducers to the Keyphasor I/O Modules or to External Termination Blocks. The 3500 Monitoring System Rack Installation and Maintenance Manual (part number 129766-01) shows how to mount External Termination Blocks. 4.1 Internal Termination Keyphasor I/O Modules For Internal Termination Keyphasor I/O Modules you must wire each Keyphasor transducer to the I/O Module individually. This section shows what the different Internal Termination Keyphasor I/O Modules look like and how to connect the wires to the Euro Style connectors that these modules use. 4.1.1 Non-Isolated Internal Termination Keyphasor I/O Module 1. Connect wires here for the Keyphasor transducer associated with Upper Keyphasor Main Module, Channel 1. 2. Connect wires here for external equipment (such as TDIX/TDXnet) associated with Upper Keyphasor Main Module, Channels 1 and 2. 3. Connect wires here for the Keyphasor transducer associated with Lower Keyphasor Main Module, Channel 2. 4. Connect wires here for external equipment (such as TDIX/TDXnet) associated with Lower Keyphasor Main Module, Channels 1 and 2. 5. Connect wires here for the Keyphasor transducer associated with Lower Keyphasor Main Module, Channel 1. 6. Connect wires here for the Keyphasor transducer associated with Upper Keyphasor Main Module, Channel 2. 34 Figure 4-1: Non-Isolated Internal Termination Keyphasor I/O Module

Section 4 - Keyphasor I/O Module Descriptions 4.1.2 Isolated Internal Termination Keyphasor I/O Module The Isolated Internal Termination Keyphasor I/O Module passes input signals through transformers to provide true isolation for 4 Keyphasor channels. The primary side of each transformer is not referenced to ground and therefore provides isolation that removes potential ground loops present in installations that connect numerous systems in parallel. The modules also give transformer-coupled signals a -10 Vdc offset after they pass through the transformers. This improves the range of input signals that you can apply to the Keyphasor Main Module without internal clipping. The design of the Isolated I/O module is specifically for Magnetic Pickup applications, but will work with and provide isolation for Proximitor sensor applications as long as you provide an external power supply. You should also note that the primary intent of this I/O module was for shaft speed and not phase measurements. You can use it for phase measurements, but you should note that this I/O module introduces a slightly higher phase shift than the Non-Isolated module. Refer to Section 8) for the specific phase shift associated with this I/O at different frequencies. 1. Connect wires here for the Keyphasor transducer associated with Upper Keyphasor Main Module, Channel 1. 2. Connect wires here for external equipment (such as TDIX/TDXnet) associated with Upper Keyphasor Main Module, Channels 1 and 2. 3. Connect wires here for the Keyphasor transducer associated with Lower Keyphasor Main Module, Channel 2. 4. Connect wires here for external equipment (such as TDIX/TDXnet) associated with Lower Keyphasor Main Module, Channels 1 and 2. 5. Connect wires here for the Keyphasor transducer associated with Lower Keyphasor Main Module, Channel 1. 6. Connect wires here for the Keyphasor transducer associated with Upper Keyphasor Main Module, Channel 2. Figure 4-2: Isolated Internal Termination Keyphasor I/O Module 35

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual 4.1.3 Internal Barrier Internal Termination Keyphasor I/O Module The Internal Barrier Internal Termination Keyphasor I/O Module provides 4 channels of intrinsically safe signal conditioning for Keyphasor transducers. The module has 2 internally mounted zener barrier modules, 1 barrier module for each pair of transducer channels. Systems that use the Internal Barrier Internal Termination Keyphasor I/O Module require a 3500 Earthing Module to provide an intrinsically safe earth connection. Refer to the 3500 Monitoring System Rack Installation and Maintenance Manual (part number 129766-01) for system requirements for applications that use the Internal Barrier Internal Termination Keyphasor I/O Module. 1. Connect wires here for the Keyphasor transducers associated with Lower Keyphasor Main Module, Channels 1 and 2. Note that these channels are referred to as Channels 3 and 4, respectively, from the point of view of the I/O Module. 2. Connect wires here for external equipment (such as TDIX/TDXnet) associated with Lower Keyphasor Main Module Channels 1 and 2. 3. Connect wires here for the Keyphasor transducers associated with Upper Keyphasor Main Module Channels 1 and 2. 4. Connect wires here for external equipment (such as TDIX/TDXnet) associated with Upper Keyphasor Main Module Channels 1 and 2. Figure 4-3: Internal Barrier Internal Termination Keyphasor I/O Module 4.1.4 Euro Style Connectors It is often easier for you to wire connections to a Euro Style connector by removing the connector terminal block from its base, making the connections at the terminal block, and then securing the terminal block back to its base. To remove a Euro Style connector terminal block from its base, loosen the screws 36

Section 4 - Keyphasor I/O Module Descriptions attaching the terminal block to the base, grip the block firmly and pull. Do not pull the block out by its wires because this could loosen or damage the wires or connector. Figure 4-4: Typical Module With Euro Style Connectors Refer to the 3500 System Field Wiring Diagram Package (part number 130432-01) for the recommended wiring. Remove no more than 6 mm (0.25 inches) of insulation from the wires. Figure 4-5: Connecting Field Wiring to a Euro Style Connector 4.2 External Termination Keyphasor I/O Modules External Termination Keyphasor I/O Modules simplifies the wiring to the Keyphasor I/O Modules in a 3500 Rack by using a 9-pin cable to route the signals from 2 Keyphasor transducers to the Keyphasor I/O Module. This section 37

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual describes the External Termination Keyphasor I/O Modules and the External Termination Block. It also includes signal pin outs of the cables that connect the External Termination Keyphasor I/O Modules and the External Termination Block. 4.2.1 Non-Isolated External Termination Keyphasor I/O Module 1. Connect the 9-pin cable (part number 129530-XXXX-XX) here for the External Termination Block associated with Upper Keyphasor Main Module, Channels 1 and 2. 2. Connect the 9-pin cable (part number 129530-XXXX-XX) here for the External Termination Block associated with Lower Keyphasor Main Module, Channels 1 and 2. 3. Connect wires here for external equipment (such as TDIX/TDXnet) associated with Lower Keyphasor Main Module, Channels 1 and 2. 4. Connect wires here for external equipment (such as TDIX/TDXnet) associated with Upper Keyphasor Main Module, Channels 1 and 2. Figure 4-6: Non-Isolated External Termination Keyphasor I/O Module 4.2.2 Isolated External Termination Keyphasor I/O Module 38 The Isolated External Termination Keyphasor I/O Module passes the input signals through transformers to provide true isolation for 4 Keyphasor channels. The primary side of each transformer is not referenced to ground and therefore provides isolation that removes potential ground loops present in installations that connect numerous systems in parallel. The module also gives

Section 4 - Keyphasor I/O Module Descriptions transformer-coupled signals a -10 Vdc offset after they pass through the transformers. This improves the range of input signals that you can apply to the Keyphasor Main Module without internal clipping. The design of the Isolated I/O module is specifically for Magnetic Pickup applications, but will work with and provide isolation for Proximitor applications as long as you provide an external power supply. You should also note that the primary intent of this I/O module was for shaft speed and not phase measurements. You can use it for phase measurements, but you should note that this I/O module introduces a slightly higher phase shift than the Non-Isolated module. Refer to section 8) for the specific phase shift associated with this I/O at different frequencies. 1. Connect the 9-pin cable (part number 129530-XXXX-XX) here for the External Termination Block associated with Upper Keyphasor Main Module, Channels 1 and 2. 2. Connect the 9-pin cable (part number 129530-XXXX-XX) here for the External Termination Block associated with Lower Keyphasor Main Module, Channels 1 and 2. 3. Connect wires here for external equipment (such as TDIX/TDXnet) associated with Lower Keyphasor Main Module, Channels 1 and 2. 4. Connect wires here for external equipment (such as TDIX/TDXnet) associated with Upper Keyphasor Main Module, Channels 1 and 2. Figure 4-7: Isolated External Termination Keyphasor I/O Module 39

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual 4.2.3 External Termination Blocks The External Termination Keyphasor I/O Modules can use 2 types of External Termination Blocks: 1) the Keyphasor External Termination Block with Terminal Strip Connectors, and 2) the Keyphasor External Termination Block with Euro Style Connectors. 4.2.3.1 Keyphasor External Termination Block With Terminal Strip Connectors 1. Connect wires here for the Keyphasor transducers. 2. Connect the 9-pin cable(s) (part number 129530-XXXX-XX) here for the External Termination Keyphasor I/O Module. The 2 cable connectors are labeled Top and Bottom corresponding to the associated Upper and Lower Keyphasor Main Modules, respectively. 3. Use this set of terminals for wiring to Lower Keyphasor Main Module, Channels 1 and 2. 4. Use this set of terminals for wiring to Upper Keyphasor Main Module, Channels 1 and 2. Figure 4-8: Keyphasor External Termination Block With Terminal Strip Connectors 40

Section 4 - Keyphasor I/O Module Descriptions 4.2.3.2 Keyphasor External Termination Block With Euro Style Connectors 1. Connect wires here for the Keyphasor transducers. 2. Connect the 9-pin cable(s) (part number 129530-XXXX-XX) here for the External Termination Keyphasor I/O Module. The 2 cable connectors are labeled Top and Bottom corresponding to the associated Upper and Lower Keyphasor Main Modules, respectively. 3. Use this set of terminals for wiring to Lower Keyphasor Main Module, Channels 1 and 2. 4. Use this set of terminals for wiring to Upper Keyphasor Main Module, Channels 1 and 2. Figure 4-9: Keyphasor External Termination Block With Euro Style Connectors 4.2.4 External Termination Block Cable Signal Pinouts The following shows the signal pinouts used to connect Keyphasor transducer signals from Keyphasor External Termination Blocks to External Termination Keyphasor I/O Modules. The cable is part number 129530-XXXX-XX. 41

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual 1 2 3 3 1. Male Keyphasor I/O connector, J1 2. Male external termination (ET) block connector, J2 3. Shield to connector shell Figure 4-10: External Termination Block Cable Signal Pinouts 42

Section 5 - Maintenance 5. Maintenance The design of the printed circuit boards and components inside 3500 Modules, including the Keyphasor Module, cannot be repaired in the field. Maintenance of 3500 Rack modules consists of testing module channels to verify that they are operating correctly, and replacing a faulty module with a spare. This section describes how to verify correct operation of a Keyphasor Module. When performed properly, you may install the Keyphasor Module into or remove the module from the rack while power is applied to the rack. Refer to the 3500 Monitoring System Rack Installation and Maintenance Manual (part number 129766-01) for the proper procedure. Application Advisory You may lose machinery protection while performing Keyphasor Module maintenance operations. 5.1 Verifying Keyphasor Module Operation The 3500 Monitoring System is a high-precision instrument that requires no calibration. You must, however, verify the functions of Keyphasor Module channels at regular intervals. At each maintenance interval, we recommend that that you exercise the procedures in this section to verify the operation of all active channels in the Keyphasor Module. 5.1.1 Choosing a Maintenance Interval Start with an interval of one year and then shorten the interval if any of the following conditions apply: - The monitored machine is classified as critical. - The 3500 Rack is operating in a harsh environment, such as that of extreme temperatures, high humidity or corrosive atmospheres. At each interval, use the results of the previous verifications and ISO Procedure 10012-1 1992(E) to adjust the interval. 5.1.2 Required Verification Test Equipment The equipment that you will need to conduct module verification testing consists of: Signal function generator 43

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual Multimeter DC power supply Laptop or other computer running 3500 Rack Configuration Software 5.1.3 Typical Verification Test Setup Figure 5-1 shows the typical test setup for verifying a Keyphasor Module. The signal function generator and dc power supply simulate the transducer signal and dc bias input to the module. The multimeter is useful for verifying signal levels. The laptop computer is for you to observe the output from the Rack Configuration Software during the tests. You also use it to save the current rack configuration prior to conducting the tests, and to restore the saved configuration afterwards. 1 4 2 3 1. 3500 Rack 2. Signal generation / verification test equipment 3. RS-232 communications cable 4. Laptop computer running 3500 Rack Configuration Software Figure 5-1: General Layout for Maintenance Testing You can connect transducers to a 3500 Rack in a variety of ways. Depending on the type of Keyphasor I/O Module you are using, connect the test equipment to the Keyphasor transducer input terminals per Figure 5-2. 44

Section 5 - Maintenance 1 2 3 4 5 1. Location of Keyphasor transducer input terminals on various I/O modules and termination blocks. 2. Internal Barrier Internal Termination Keyphasor I/O Module. 3. Internal Termination Keyphasor I/O Module (Non-Isolated or Isolated). 4. Keyphasor External Termination Block With Euro Style Connectors (used with External Termination Keyphasor I/O Modules). 5. Keyphasor External Termination Block With Terminal Strip Connectors (used with External Termination Keyphasor I/O Modules). Figure 5-2: Location of Keyphasor Transducer Input Terminals 5.1.4 Using 3500 Rack Configuration Software For Verification Testing To perform the test procedures described in this section you must be familiar with the following features of the 3500 Rack Configuration Software: Uploading, Saving and Downloading of Configuration Files Display of the Verification Utility Screen The 3500 Monitoring System Rack Configuration and Utilities Guide (part number 129777-01) explains how to perform these operations. NOTE It is important that you save the original rack configuration before performing any maintenance or troubleshooting procedures and restore the rack configuration to its original state afterwards. 45

3500/25 Enhanced Keyphasor Module Operation and Maintenance Manual Figure 5-3 depicts a typical screen view of the 3500 Rack Configuration Software, Verification Utility Screen. You may access this screen by selecting Utilities/Verification from the main menu screen of the 3500 Rack Configuration Software. Figure 5-3: 3500 Rack Configuration Software Verification Utility Screen The module channel verification procedure uses the information displayed on this screen. 5.1.5 Procedure For Verifying Keyphasor Module Channels This section shows how to verify correct operation of Keyphasor Module channels. This procedure tests the Threshold, RPM, and OK Status values for each channel of the Keyphasor Module. You verify and check the values by varying the input Keyphasor signal frequency and the applied dc bias and then observing that the 3500 Rack Configuration Software Verification screen reports the correct results on the test computer. Refer to Figure 5-4. NOTE Test equipment outputs should be floating relative to earth ground. 46