DATASHEET ULTRASONIC COMPACT ENERGY METER MODEL 773

Similar documents
EW773 Series Ultrasonic Hydronic Meters FOR HEATING AND COOLING APPLICATIONS

SONOMETER TM 500 Ultrasonic compact energy meter

SITRANS F flowmeters SITRANS F US. SITRANS FUE950 energy calculator. 4/240 Siemens FI

SonoSelect and SonoSafe energy meters

Entering a Whole New Dimension The ULTRAHEAT XS Heat Meter

MID approval no. DE-08-MI004-PTB004 Date of release

SonoSelect 10 and SonoSafe 10 energy meters

SITRANS F US Inline. SITRANS FUE950 energy calculator 4/269

PolluTherm. Integrator for measuring heating and cooling energy. Main characteristics. Available design.

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

EW500 Series Energy Calculators FOR HEATING AND CHILLED WATER ENERGY METERING

EW773 Series Ultrasonic Hydronic Meters DN FOR HEATING AND COOLING APPLICATIONS

2 CLASS AMR READY INVONIC H DATA APPLICATION HEAT METERING. approved ULTRASOUND HEAT AND COOLING METERS DN15, DN20, DN25, DN40, DN50

EW170 Series Woltman Bulk Water Meters DN FOR COLD AND WARM POTABLE WATER APPLICATIONS

Solenvis SL80 Pulse to M-Bus Converters

Heat meter User guide Sharky Heat Meters

User guide. SonoMeter 30. Ultrasonic energy meter for heating and cooling applications. Danfoss VUIGI102 1

Immersion Temperature Sensors

PolluTherm. calculator hous. 2 from hous. 1 until X X X X X* X* M-Bus- M-Bus and 2 2PM pulse inputs X X X X

PN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06...

All it takes to measure, collect and analyze energy consumption in heating and cooling applications

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

SonoMeter 30 Ultrasonic energy meter for heating and cooling applications

EC 600 Electronic Volume Corrector

Absolute Encoders Multiturn

M-Bus Modules. Data sheet. for MULTICAL 403

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

PADPULS2 M-BUS Pulse Input Modules

FAUN PROFESSIONAL, NEW GENERATION INDICATING CALCULATOR FOR SEPARABLE HEAT METERS

CHP GAS MONITOR GDR 1404

SonoMeter 30 Ultrasonic energy meter for heating and cooling applications

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

RoHS. High shaft load capacity. Shock / vibration resistant

CHP GAS MONITOR GDR 1404

Level Measurement Continuous level measurement - Ultrasonic transmitters

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Innovation on the right wavelength. Level measurement in compact tanks using microwave technology.

CALEC energy master The benchmark in energy measurement

Wired M-Bus Modules. Data sheet. for MULTICAL 403 and 603

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values

Hyamaster r SPS. Intelligent single and multiple pump control system with continuous speed control by frequency inverter, with PLC SIMATIC r S7

RESIDENTIAL WATER METERS GSD5 1/2" AF GSD5 3/4" AF ,00 GSD8 1/2" AF GSD8 3/4" AC

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level measurement. Applications. Special features. Description

Rotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/221

DATA SHEET. Advanced Energy Meter, AEM 380 & AEM 305

Electro-Mechanical Counters

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

M-Bus Central Unit. Use

WTX110. Legal-for-trade industrial weighing terminal. Special features. Data sheet

Online data sheet. FW101 Ex SCATTERED LIGHT DUST MEASURING DEVICES

Series DiTemp Series SolarTemp. Digital Thermometers

SITRANS T measuring instruments for temperature

Flow VA 500/

DIAGNOSTICS PN# / / FSP

tapcon 230 user-friendly, FleXiBle and reliable. transformer control

EElectronic Devices and Systems. EK-87 Electronic Volume Corrector. This product is discontinued!

Technical data. General specifications. factory setting: 125 ms Memory Non-volatile memory Write cycles Indicators/operating means

Thermal Mass Flowmeter Sensyflow FMT200-D

with Backlight Graphic LCD Screen

C-Flow Coriolis Mass Flow Meter

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Level sensor Stainless steel version Model RLT-1000, for industrial applications

AEW36.2. Pulse Adapter. Siemeca AMR

Product Catalog. Belgium Tel.: +32 (0) The Netherlands Tel.: +31 (0)

Automation System TROVIS 5400 District Heating Controller TROVIS 5476

60 Ghz - Radar filling level sensor RFM 2000 C4 / R / MD

Rotary Position Technology Incremental Encoders

Series DMHF Heat Meter

Precision Hand-held Thermometer

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100 SERIES

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

AEW36.2. Pulse Adapter. Building Technologies. Siemeca AMR

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_

Static Heat Meter ULTRAHEAT XS 2WR6... UH f. Configuration and composition

SITRANS P measuring instruments for pressure

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Installation Instructions Temperature transmitter TAA /00 06/2011

B 201 A B C. dynamx variable flow-control valves, series DXMB_C. Dynamic Flow Networking. Description. Content

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

The network node works extremely well in more complex building environments (e.g. where fire doors/glass walls are installed).

Ultrasonic Heat Flow Meters

M-Bus Central Unit OZW10

SHARKY BR773. Communication Description. Software Version 28

LiquiDens. SensoTech. Process density meter for liquids Product description

KS 108 easy Compact automation unit for industrial control and process technology

Ultra Sonic Flowmeter DATASHEET

Metering systems 0670EN February 2014 Volumetric thermal energy meters for use in a boiler room GE552-1 series

Absolute Encoders Multiturn

Online data sheet. FLOWSIC100 Flare MASS FLOW MEASURING DEVICES

Transcription:

APPLICATION Static compact energy meter using ultrasonic technology Highly accurate recording of all billing data in local and district heating and cooling systems FEATURES 1st. approval in Europe for ultrasonic meter with dynamic rage of qi/qp 1:250 in class 2 (qp 1.5 / 2.5 / 6.0 m 3 /h) complete dynamic range 1:1500 Lithium battery (lifetime 12 years, 16 years optional), 230 V AC or 24 V AC main supply HEAD LOSS DIAGRAM Patented free-beam principle Improved service-friendly meter design housing up to 190 mm thread and flange (PN 16 / PN 25) Can be used as cooling, heating or combined climatic meter Temperature range 5-130 C/150 C Overload temperature up to 150 C Swirl-free flow around reflector New construction > lower pressure loss Robust stainless steel reflector Available in nominal sizes q p 0.6-1.0-1.5-2.5-3.5-6.0 m 3 /h Measuring accuracy meets the requirements of EN1434 class 2 and 3 No calming sections necessary in the inlet and/or outlet (standard installation) Insensitiv against magnetite in the liquid MEASURING ACCURANCY TO EN 1434 CLASS 2 SPECIAL FEATURES Power save mode NOWA test capability Remote reading via M-Bus, Radio, RS232 or optical interface Optional Plug & Play modules Individual tariff functions History memory for 24 months Extensive diagnostic displays HYDRO-SET parametrization software on Windows basis guarantees optimum adaptation to the user s specific needs

GENERAL Static compact energy meter with fully electronic measurement based on the ultrasonic principle Storage of volume and energy data COMPONENTS Ultrasonic volume measuring component Integrator with integral hardware and software for measuring flow rate, temperature and energy consumption Temperature sensors INTEGRATOR The integrator contains all the necessary circuits for recording the flow rate and temperature and for calculating, logging and displaying the data. The integrator housing can be mounted directly on the volume measuring component or on the wall. The meter can be conveniently read from a single-line 7-digit display with units and symbols. A pushbutton provides user-friendly control of the various display loops. All failures and faults are recorded automatically and shown on the LC display. To protect the reading data, all the relevant data are saved in a non-volatile memory (EEPROM). This memory saves the measured values, device parameters and types of error at regular intervals. ULTRASONIC VOLUME MEASURING COMPONENT The ultrasonic technology of the volume measuring component permits very high measuring accuracy and can be used in the forward or return line. The volume measuring component meets the requirements of EN 1434 / class 2 and 3. The standard cable length between the calculator and the volume measuring component is 1.5 m (5m optional). Supply voltage: Lithium battery 3.0 V DC (12-year life) Lithium battery 3.6 V DC (16-year life) optional Mains unit 230 V AC or 24 V AC TEMPERATURE SENSORS Pairs of Pt 100 or Pt 500 temperature sensors (Ø 5.2 mm) with 2-wire leads are used as a standard. INTERFACES SHARKY is equipped as standard with a ZVEI optical interface with the M-Bus protocol as per EN 1434. This interface is used, for example, for communication with the HYDRO-SET parameterization software. The meter features 2 slots for the modules. One slot for the function modules, and one for the communication modules. The following communication modules are available as options: Real Data Radio Module M-Bus module to EN 1434 RS 232 module The RS 232 module is a serial interface and permits data exchange with the heat meter. For this purpose a special data cable is necessary (please find order references). The Radio module communicates a list of predefined data records. This can be edited by HYDRO-SET. PULSE INPUT Two additional pulse inputs are available. The pulse value and the unit is configurable for energy, water, gas or electrical meter by HYDRO-SET. Also two accounting day s are available for both inputs. PULSE OUTPUT The meter provides levels for two optional external pulse outputs, which can be freely programmed using the HYDRO-SET software. Possible pulse output values Energy (standard setting) Volume (standard setting) Tariff energy 1 Tariff energy 2 Tariff condition 1, limit switch Tariff condition 2, limit switch Energy error Volume error MODULE COMBINATIONS The following module combinations for data transmission are available ex works or for retrofitting in the field. Function modules: Pulse input module Pulse output module Communication modules: M-Bus or RS 232 or Real Data Radio

ACCESSORIES/SOFTWARE The HYDRO-SET parametrization software based on the M-Bus is a convenient tool for handling the meter. It runs on WINDOWS 2000/XP and is used for: taking meter into operation reading out different memories printing out meter logs meter configuration Further information about the HYDRO-SET software is available for free downloading from our website at www.hydrometer.com/systems/downloadcenter.html Reading the meter on a certain day. Example: If the day for reading is 01.10, the meter reading is displayed for the period from 01.10 of the previous year to 30.09 of the current year. Comparison of the last consumption period with the preceding period EVENT MEMORY Events such as changes and faults are stored in a non-volatile memory with a capacity of up to 31 entries. The following events are recorded: Checksum error Temperature measurement error Ultrasonic echo time measurement errors Start and end of test mode MONTHLY MEMORY SHARKY has a history memory of 24 months. The following values are stored in the EEPROM on the programmed date 1... 31 via (HYDRO-SET) of the actual month: Date/Time Energy Tariff energy 1 Tariff energy 2 Tariff definition 1 Tariff definition 2 Volume Error day counter Maximum monthly flow rate Maximum monthly power Date of maximum monthly flow rate Date of maximum monthly power Impulse input 1 Impulse input 2 Table 1 MAX. VALUES The integrator creates max. values for power and flow rate based on consumption time, which are stored in the EEPROM. The integration intervals are adjustable to 6, 15, 30 or 60 minutes or 24 h. Default setting is 60 minutes. TARIFF FUNCTION The integrator offers two optional tariff memories for monitoring plant load states for limit tariffs. Extensive tariff conditions make it possible to adapt the meter individually to the required customer-specific applications. Apart from the energy a time-based tariff can also be programmed. The following limit types are possible: (This example applies to the display with 3 decimal places) LOG MEMORY The log memory is used to store consumption values. The storage frequency can be selected from various storage intervals (1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30, 60 minutes or the default setting of 24 hours, see Table 1). The data saved in the log memory can be used for the following analyses:

DISPLAY CONTROL The readings are displayed on the meter by a 7-digit LCD with units and symbols. LOOP STRUCTURE The SHARKY-HEAT display has six loops. Some display windows consist of two (to maximum seven) displays that are shown alternately at 4-second intervals. Some pictures in loops can be deactivated separately. Note: For quick visual guidance, the loops in the display are numbered from 1 to 6. The main loop with the current data, e.g. for energy, volume and flow rate, is programmed as default setting. In the standard setting the loop no. 5 (tariff loop) is not activated OVERVIEW OF LOOPS

INFORMATIVE DISPLAYS (STANDARD) 3 [OFF] = not active

SIMPLE OPERATION A pushbutton mounted on the front of the meter is used to switch to the various displays. The button can be pressed for a short or long time. A short press of the button (< 3 seconds) switches to the next display within a loop and a long press (> 3 seconds) switches to the next display loop. The "Energy window (sequence 1.1) in the main loop is the basic display. The meter switches automatically to power save mode if the button is not pressed for approx. 4 minutes and returns to the basic display when the button is pressed again. The loop settings can be programmed to suit the customer s individual requirements using the HYDRO-SET software.

DIMENSIONS

TECHNICAL DATA DATASHEET ULTRASONIC COMPACT ENERGY METER

Please complete this sheet and return it to HYDROMETER by Fax, Email or Mail

MODULES ACCESSORIES ADAPTERS FOR TEMPERATURE SENSORS ADAPTERS FOR TEMPERATURE SENSOR MOUNTING HYDROMETER GmbH PO.Box 1462 91505 Ansbach/Germany Delivery address: Industriestrasse 13 91522 Ansbach/Germany www.hydrometer.de Phone: +49 (0)981/1806-0 Fax: +49 (0)981/1806-605 and -615