Characterization of microshells experimented on Laser Megajoule using X-Ray tomography

Similar documents
Comparison of Probing Error in Dimensional Measurement by Means of 3D Computed Tomography with Circular and Helical Sampling

Adapted acquisition trajectory and iterative reconstruction for few-views CT inspection

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY

Developments in Dimensional Metrology in X-ray Computed Tomography at NPL

Recognition and Measurement of Small Defects in ICT Testing

Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system

Frequency-based method to optimize the number of projections for industrial computed tomography

Investigating the influence of workpiece placement on the uncertainty of measurements in industrial computed tomography

THREE DIMENSIONAL INDUSTRIAL METROLOGY USING X-RAY COMPUTED TOMOGRAPHY ON COMPOSITE MATERIALS

Registration concepts for the just-in-time artefact correction by means of virtual computed tomography

Sensor based adaptive laser micromachining using ultrashort pulse lasers for zero-failure manufacturing

Arion: a realistic projection simulator for optimizing laboratory and industrial micro-ct

Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE

CHARACTERIZATION OF THE MICROSHELL SURFACE USING HOLOGRAPHIC MEASUREMENTS

X-rays see all X-ray computed microtomography (µct) a novel technique available at CERN for material and metrological inspection

Methods for Quantitative Characterization of Large-Scale High Energy Computed Tomography Systems

Coordinate Measuring Machines with Computed Tomography

Wieblinger Weg 92a, Heidelberg, Germany, Phone: , Fax: ;

NDT OF SPECIMEN OF COMPLEX GEOMETRY USING ULTRASONIC ADAPTIVE

TEP Hounsfield units. Related topics Attenuation coefficient, Hounsfield units

ASSESSMENT OF MEASUREMENT UNCERTAINTY CAUSED IN THE PREPARATION OF MEASUREMENTS USING COMPUTED TOMOGRAPHY

Parameter Dependent Thresholding for Dimensional X-ray Computed Tomography

Experimental accuracy assessment of different measuring sensors on workpieces with varying properties

Quality control phantoms and protocol for a tomography system

Investigation of the kinematic system of a 450 kv CT scanner and its influence on dimensional CT metrology applications

How beam hardening influences the dimensional geometry in X-ray computed tomography

TOLERANCE ANALYSIS OF THIN-WALL CFRP STRUCTURAL ELEMENTS USING TOMOGRAPHIC IMAGING

Digital Image Processing

CT Reconstruction with Good-Orientation and Layer Separation for Multilayer Objects

CIVA Computed Tomography Modeling

High-resolution X-ray CT Inspection of Honeycomb Composites Using Planar Computed Tomography Technology

Advanced Reconstruction Techniques Applied to an On-Site CT System

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS

3D Computed Tomography (CT) Its Application to Aerospace Industry

Méthodes d imagerie pour les écoulements et le CND

Using X-Ray Micro Tomography to assess the quality of Packaging Foil

Investigation on reconstruction methods applied to 3D terahertz computed Tomography

Flexible EC Array Probe for the Inspection of Complex Parts Developed Within the European VERDICT Project

Digital phantoms for the evaluation of a software used for an automatic analysis of the Winston-Lutz test in image guided radiation therapy

Dr. Javier Santillan, San Carlos, CA

3D X-ray Laminography with CMOS Image Sensor Using a Projection Method for Reconstruction of Arbitrary Cross-sectional Images

Digital Volume Correlation for Materials Characterization

3D X-ray Microscopy Characterization. Metal Additively Manufactured Parts. Application Note

On the impact of probing form error on form measurement in Computed Tomography

DUE to beam polychromacity in CT and the energy dependence

Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image Processing Techniques

More Info at Open Access Database

Multi-spectral (W, Mo, Cu, and Ag) XCT measurements

The PolyCT Increasing the sample throughput using multiple rotation axes

Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications

An initial experimental study on the influence of beam hardening in X-ray CT for dimensional metrology

Evaluation strategies in CT scanning

Phase-Contrast Imaging and Tomography at 60 kev using a Conventional X-ray Tube

Computed tomography (Item No.: P )

ULTRASONIC TESTING AND FLAW CHARACTERIZATION. Alex KARPELSON Kinectrics Inc., Toronto, Canada

Advanced Non-Destructive Testing by High Resolution Computed Tomography for 3D analysis of Automotive Components

Japan Foundry Society, Inc. Application of Recent X-ray CT Technology to Investment Casting field. Kouichi Inagaki ICC / IHI Corporation

Industrial Computer Tomography for Dimensional Metrology: Overview of Influence Factors and Improvement Strategies

Comparison between 3D Digital and Optical Microscopes for the Surface Measurement using Image Processing Techniques

A PRACTICAL ALGORITHM FOR RECONSTRUCTION FROM X-RAY

International Symposium on Digital Industrial Radiology and Computed Tomography - Mo.2.2

LABORATORY SYSTEM FOR X-RAY NANOTOMOGRAPHY

Novel evaluation method of low contrast resolution performance of dimensional X-ray CT

Simulation Supported POD Methodology and Validation for Automated Eddy Current Procedures

CT Systems and their standards

THREE DIMENSIONAL EXAMINATION OF DIRECTIVITY PATTERN IN IMMERSION TANK TESTING

Scatter Correction Methods in Dimensional CT

Image Acquisition Systems

Performance Evaluation of 3-Axis Scanner Automated For Industrial Gamma- Ray Computed Tomography

Investigation on the influence of image quality in X-ray CT metrology

18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa

Process Monitoring using three dimensional Computed Tomography and Automatic Image Processing

Process Monitoring using Three Dimensional Computed Tomography and Automatic Image Processing

NKS GammaUser

Comparision of contact and contactless measuring methods for form evaluation

Combining Analytical and Monte Carlo Modelling for Industrial Radiology

AUTOMATED HIGH SPEED VOLUME COMPUTED TOMOGRAPHY FOR INLINE QUALITY CONTROL

Ch. 4 Physical Principles of CT

Radiographic Simulator artist: Version 2

CIVA CT, an advanced simulation platform for NDT

Comparison of Reconstruction Methods for Computed Tomography with Industrial Robots using Automatic Object Position Recognition

Simulation of Radiographic Testing for POD Assessment

Optimisation of the process of X-ray tomography applied to the detection of defects in composites materials

INVESTIGATION OF MEASURING STRATEGIES IN COMPUTED TOMOGRAPHY

Application of 450 kv Computed Tomography to Engine Blocks with Steel Liners

Reducing the influence of environmental scattering in industrial computed tomography by system optimisation and correction algorithms

MULTI-PURPOSE 3D COMPUTED TOMOGRAPHY SYSTEM

MULTI-MODALITY 3D VISUALIZATION OF HARD-ALPHA IN TITANIUM

Translational Computed Tomography: A New Data Acquisition Scheme

Inspection of Laser Generated Lamb Waves using Shearographic Interferometry

Good Practice guide to measure roundness on roller machines and to estimate their uncertainty

An Acquisition Geometry-Independent Calibration Tool for Industrial Computed Tomography

Ultrasonic Multi-Skip Tomography for Pipe Inspection

Case Studies in the Use of Computed Tomography for Non-Destructive Testing, Inspection and Measurement

NON-COLLIMATED SCATTERED RADIATION TOMOGRAPHY

Creating a Multi-material Probing Error Test for the Acceptance Testing of Dimensional Computed Tomography Systems

Energy resolved X-ray diffraction Cl. J.Kosanetzky, G.Harding, U.Neitzel

Coupling of surface roughness to the performance of computer-generated holograms

Full 3D scan of an AGATA crystal using the PSCS technique

Transcription:

Characterization of microshells experimented on Laser Megajoule using X-Ray tomography More info about this article: http://www.ndt.net/?id=20881 Alexandre Choux, Lise Barnouin, Ludovic Reverdy, Marc Theobald CEA, Centre de Valduc, F-21120 Is Sur Tille, France, e-mail: alexandre.choux@cea.fr Abstract Some targets experimented on the Laser Megajoule (LMJ) facility are composed of amorphous hydrogenated carbon microshells. Some of them present rippled surface features like sinusoidal functions. The main difficulty when analyzing these microshells is to characterize the feature s orientation and engraving depth. An X- Ray tomography is used to measure them. This work details the methodology and gives results obtained. Keywords: LMJ targets, dimensional characterization, X-ray tomography 1 Introduction As part of the Laser-Megajoule (LMJ) [1, 2] program, the French CEA (Commissariat à l Energie Atomique et aux Energies Alternatives) designs, develops and fabricates targets or components of target with drastic specifications in order to study astrophysic hydrodynamics for instance). To match and to control these specifications, process and characterization devices have to be continuously improved. Some targets or components are amorphous hydrogenated carbon microshells. Their outer diameters vary between 500 µm to 2000 µm with a thickness belonging to 10 µm to 200 µm. Some of these microshells present rippled surface features like sinusoidal functions. Peak to peak amplitude > 4 µm Figure 1: An example of microshell with a sinusoidal shape. A non-destructive characterization process was performed using an X-ray microtomography to obtain precisely the microshell s feature orientation and engraving depth. This paper presents the method and results obtained on the microshell s features characterization. First, the key factors influencing the measurement are overviewed. This allows improving the quality of the data acquisitions and the definition of the processing parameters. All optimized factors then lead to the characterization of the feature s orientation and engraving depth. 2 Metrology s key factors As dimensional metrology is a recent field of (CT) computed tomography applications, many studies [3] were focused on improving it by determining key factors. Some of these key factors can have no effects on CT work pieces as the beam hardening when characterizing plastic microshells. Among these key factors, the voxel size, the number of projections and the data filtering are those that only influence the measurement of the low X-ray absorption material.

2.1 The voxel size and the number of projections Voxel size: The voxel size is a major contributor to the dimensional resolution of the CT reconstructed sample. It is often used as a measure of the smallest defect or object contained in the sample. In other words, the smaller is the voxel size, the best is the dimensional resolution. Number of projections: The reconstructed sample resolution for the computed tomography systems also depends on the number of projections. The reconstruction is improved by increasing the number of projections. 2.2 Data filtering Data filtering means the removal of unwanted information (noise) added to the signal of interest. Data filtering used on CT system for noise removal can be applied at many stages of the CT dimensional characterization, e.g. on the projections or during the reconstruction. The main perturbations for the reconstruction of low absorption sample are the ring artifact and the phase contrast imaging. Ring artifacts are CT phenomena which occur when there is a miscalibration or a failure of one or more detector elements in a CT system. They are usually observable close to the scan isocentre and at the same location on each slice. They represent a common problem in the low absorption sample tomography acquisition. Phase contrast imaging is based on phase effects and occurs due to light element being in the sample. It occurs close to the internal and external surfaces. 3 X-ray microtomography and methods 3.1 X-ray microtomography system The X-ray tomography system is implemented in a clean room. The room temperature is (21 ± 1) C. The hardware characteristics of the X-ray tomography system are presented in Table 1. Max. Voltage Max. Current Target material Filament alignment Table 1: Hardware characteristics Tube Window Max. Src- Sensor distance Sensor material Sensor pixels nb. Sensor pixel pitch 160 kv 50 µa Tungsten Automatic Be 800 mm Gadox 4008 x 2672 9 µm 3.2 Data processing software All the tomography data processing operations required to obtain the final reconstructed volume (e.g. beam hardening correction, phase contrast correction, ring artefact, reconstruction ) are performed with the tomography operating software (see Ref. [4]). Each sub-volume of interest defined by its external surface is localized by using geometrical predefined surfaces implemented in the tomography data processing software quoted in the reference [5]. 4 Microshell s characterization 4.1 Microshell The microshell is an amorphous hydrogenated carbon sphere (654 µm diameter; 47 µm thick). The feature [6] is machined as a sinusoidal shape with a 4 µm peak-to-peak amplitude and a 100 µm modulation period. 4.2 Measurements The X-ray acquisition parameters for the microshell CT scan are presented in Table 2. Measurements were taken on the previously described microshell with a 0.6 µm voxel side size.

Table 2: Microshell CT acquisition parameters Voltage Current Target Tube Sensor Number of Voxel size material Window material projections Frame rate 40 kv 10 µa Tungsten Be 0.6 µm Gadox 1568 5 images/s The final reconstruction allows observing the sinusoidal shape on the outer surface of the microshell (See Fig. 2). Figure 2: CT reconstruction of a microshell with a sinusoidal shape. With the data processing software, the thickness of the microshell at each point can be characterized. A global representation illustrates the thickness variation (see figure 3). Figure 3: Microshell thickness variation. The data processing software does not allow characterizing a sinusoidal shape. As an approach to estimate the characteristics of a sinusoidal function, points are picked on the outer surface of the microshell (see figure 4), such that they define peaks and valleys on the sinusoidal shape. Figure 4: Points picked on the outer surface of the microshell.

Since the microshell is machined along 210 around one microshell revolution axis, 16 cross sections are extracted. That means a cross section is chosen every 15. Figure 5: Example of a cross section from the reconstructed microshell. On each cross section containing the microshell revolution axis, points are placed on the peaks and on the valleys of the sinusoidal shape. Experimental profiles, such as each profile corresponds to one microshell s longitude, are then extracted from the reconstructed microshell (see figure 6). 50 45 Extracted profiles of the sinusoidal feature Thickness (µm) 40 35 30 25 Longitude 272 Longitude 317 Longitude 362 Longitude 407 Longitude 432 20 0 50 100 150 200 Angular position ( ) along a longitude Figure 6: Examples of extracted profiles. Since the feature machining is not perfect, there is depth deviation. To model the sinusoidal shape, the depth has to be taken into account. The model that was empirically determined is:..sin. With the angular position (deg) along a microshell longitude, b the amplitude (µm) of the sinusoidal shape, c the pulse of the sinusoidal shape, d (µm) and a (µm.deg -2 ) parameters of the depth deviation function. For each extracted profile, each parameter is estimated (see figure 7) by respecting the following criteria R P < 0.5. The coefficient R P is defined by the formula:

With the number of points placed on the peaks and on the valleys of the sinusoidal shape, the microshell thickness at the angular position, the evaluated model at the angular position. 50 Extracted profile vs modelled profile for the 407 longitude Thickness (µm) 45 40 35 30 25 20 ()=25.5+9.10 4 +2.7 sin(20.2 ) 0 20 40 60 80 100 120 140 160 Angular position ( ) Figure 7: Example of extracted profile versus modelled profile. Extracted profile Estimated profile After analyzing the whole set of profiles, each parameter mean is computed. Thus the pulse c of the sinusoidal signal is equal to 20.1 and the amplitude b is equal to 2.5 µm. The standard deviation is computed for the amplitude and the pulse. The other parameters a and d are not constant. They are parameters only to estimate locally the sinusoidal shape machined on the microshell. The determined model for this microshell is:. 2.5 sin 20.1. The modulation period of this sinusoidal shape is determined using the formula given in [6]: #$ %&, ' with () the outer microshell radius (µm), * the modulation period (µm) and c is the pulse of the sinusoidal signal. Table 3: Sinusoidal shape characterization Theory Experimental Standard deviation Amplitude 2 µm 2.5 µm 0.2 µm Pulse 20.5 20.1 0.2 Modulation period 100 µm 102.2 µm - 5 Conclusion An amorphous hydrogenated carbon microshell with its machined orientated feature is characterized using an X-ray microtomography with a resolution of 0.6 µm per voxel and a methodology based on a peak to valley depth evaluation. In metrology, the result of a measurement Y can be denoted by Y = y ± U, with y the best estimate of the value Y, U the expanded uncertainty of measurement. There are a lot of ways to get the measurement uncertainty [7] as Monte Carlo simulation, measurement repeatability, ray-tracing simulation, and so on... As CT metrology is a new way to characterize the microshells experimented on the Laser Megajoule, the determination of this associated measurement uncertainty stills a work in progress.

References [1] J.L. Miquel, C. Lion, and P. Vivini, "The LMJ program: Overview and Status of LMJ & PETAL Projects," CLEO: Applications and Technology, Optical Society of America, 2013. [2] C. Lion, "The LMJ program: An overview", J. Phys.: Conf. Ser. 244, 012003 (2010). [3] S. Kasperl, J. Hiller, M. Krumm, Computed Tomography Metrology in Industrial Research & Development, International Symposium on NDT in Aerospace, December 3-5, 2008, Fürth, Germany. [4] RX Solutions, X-Act 2.0. Software, 2016. [5] Volume Graphics, VGStudio Max 2.2. Software, 2016. [6] I. Geoffray, J. Andre, R. Bourdenet, J. Schunk, C. Chicanne, and M. Theobald, Sinusoidal ripples micromachining on CHx ablator for hydrodynamics growth experiments, Fusion science and technology, 2016, vol 70, 244-253. [7] Evaluation of measurement data Guide to the expression of uncertainty in measurement JCGM 100:2008.