B i o l ogical Micro sco p e. Biological Microscope ECLIPSE E200

Similar documents
Biological Microscope CX43/CX33. CX3 Series. Comfortable, High-Throughput Routine Microscopy

CCIS (Colour Corrected Infinity System) The microscope stand BA300

Upr i g ht Micro scop e. Upright Microscope ECLIPSE Ci/Ni

System Microscope CX41. CX2 Series. Optics and Performance Outstanding in its Class

BA210 BASIC BIOLOGICAL. Microscope

M50 and M50RT Series. Brightfield / Darkfield Metallurgical Microscopes

BIOLOGICAL MICROSCOPE CX31 CX2 SERIES. New standards of sharpness, clarity and flatness

BA210 Basic Biological Microscope

BA210 BASIC BIOLOGICAL MICROSCOPE

ACCURACY SIMPLICITY EFFICIENCY

M40 and M40RT Series. Metallurgical Microscopes

Polarizing Microscopes ECLIPSE LV100N POL/Ci-POL. Polarizing Microscopes

Upright Microscope. Upright Microscope ECLIPSE Ci/Ni

Upright Microscope. Upright Microscope ECLIPSE Ci/Ni

LABOMED, INC. APPLICATION

INVERTED SYSTEM MICROSCOPE IX51 IX2 SERIES. Practical Convenience and Quality Performance UNIVERSAL INFINITY SYSTEM

ZOOM STEREOMICROSCOPE SZ61/SZ51. For Biological Use. The Comfort Zone

SeBa Digital Imaging Systems

IND BA310MET SERIES ADVANCED MICROSCOPES FOR MATERIAL SCIENCES

2014 EUROPE PRICE LIST EN ES DE BA310E SERIES. Canada China Germany Spain USA

Fisher Scientific Microscopes

BA310 ADVANCED UPRIGHT MICROSCOPE

Fein. RB50 Series Research Microscopes

Palomar. Metallurgical Microscopes. Palomar Metallurgical Microscopes

Stereoscopic Zoom Microscope. Stereoscopic Zoom Microscope SMZ800

CK40M COMPACT INVERTED METALLURGICAL MICROSCOPE

BA310 Epi-LED FL. New innovative Fluorescence microscope

B1 ELITE & B3 SERIES ADVANCED BIOLOGICAL MICROSCOPES

Delphi-X Observer HIGHLIGHTS TECHNICAL SPECIFICATIONS EYEPIECE(S) HEAD MULTIHEAD SYSTEM FACE-TO-FACE DUAL HEAD SYSTEM PRODUCT DATASHEET

Innovative Solutions in Material Test Equipment

VWR Microscopes for a diverse application focus

BA210. Basic Biological Microscope.

Oxion. Microscopes for Life Sciences ENGLISH

BASIC BIOLOGICAL MICROSCOPE

BINOCULAR MICROSCOPES

Polarizing Microscopes. Polarizing Microscopes ECLIPSE LV100N POL/Ci-POL

BA210. Basic Biological Microscope

Delphi-X Observer HIGHLIGHTS TECHNICAL SPECIFICATIONS EYEPIECES STANDARD HEAD FACE-TO-FACE DUAL HEAD SYSTEM ERGONOMIC TILTING HEAD MULTIHEAD SYSTEM

Compound microscopes KERN OBF-1 OBL-1

Leica BM E. Compound Microscope System Great discoveries begin with vision.

BIOLOGICAL MICROSCOPE

BA210E BASIC BIOLOGICAL MICROSCOPE

MICROSCOPE COMPONENTS FOR TRANSMITTED LIGHT APPLICATIONS

The new standard for laboratory microscopes

IND AE2000MET SERIES INVERTED METALLURGICAL MICROSCOPE

Leica DM100 & Leica DM300. Affordable Innovation for the First-time Scientist

BA310 Advanced Upright Microscope

X-LED TM. B-350 Series B-350. Entry-level upright laboratory microscopes. Entry-level upright laboratory microscopes B-350

Infinity Flat-Field Objectives Objective Choices Eyepieces

3025 MICROSCOPE SERIES INSTRUCTIONS

Infinity Flat-Field Objectives Objective Choices Eyepieces

OPTIKA. educational microscopes

X-series C-series. english

OMM200 and OMM200T. Metallurgical Microscope

Compound microscope KERN OBE-1

BA310MET ADVANCED METALLURGICAL MICROSCOPE

Sunny Instruments. E5 Series Biological Microscope

Leica DM100 & Leica DM300. Affordable Innovation for the First-time Scientist

Polarizing Microscope LPM-A10. Features. Applications. Specifications

G500 SERIES MICROSCOPE OPERATION MANUAL For use with MFR# G502, G502T, G504, G504T, G505, G505T.

OPTIKA. Inverted biological microscopes XDS XDS-2 / XDS-2ERGO / XDS-3 / XDS-3LT. XDS Series Inverted biological microscopes

COMPACT INVERTED METALLURGICAL MICROSCOPE GX41

BA50&BA80. Educational Environments

Leading the way in automated microscopy

Motic was established in 1988 as a hi-tech industrial enterprise specialized in manufacturing

INNOVATION BIOLOGICAL MICROSCOPE

X-LED TM. B-350 Series B-350. Advanced biological microscopes for teachers. Advanced biological microscopes for teachers B-350

Primo Star Greatness is a Question of Opportunities.

IND BA310POL SERIES ADVANCED POLARIZATION MICROSCOPE

ENGLISH. MicroBlue EcoBlue MICROSCOPES FOR. BioBlue EduBlue BioBlue.Lab StereoBlue

Polarization Microscope. Omano OM349P Series. User Guide

Microscopy Redefined. Fisher Scientific Premier Microscopes

RED. Revolutionary Educational Design

Fixed Stage Microscope for Electrophysiological Research ECLIPSE FN1. Fixed Stage Microscope for Electrophysiological Research

Sunny Instruments. CX40P Polarizing Microscope

Microscope Stand. Eyepiece Tubes

BASIC BIOLOGICAL MICROSCOPE

hsilgne X-series C-series

Whitney. Polarizing Microscopes. Whitney Polarizing Microscopes

HumaScope Line. CoreLab DX. Affordable Microscopes Fitting to Your Needs. HumaScope Line

2014 EUROPE PRICE LIST EN ES DE BA310 SERIES. Canada China Germany Spain USA

OPTIKA EDUCATIONAL MICROSCOPES. ECOVISION SERIES - Entry-level biological microscopes for students page 5

IC Inspection Wafer Loaders NWL860/641. Series

3002 MICROSCOPE SERIES. microscopes are engineered to the highest quality standards ACCU-SCOPE. Delivering Quality thru Vision

Operation Manual. VWR Inverted Microscope. (Version 1.0.0) VWR Inverted Microscope VWR Inverted Microscope.

AE2000MET INVERTED METALLURGICAL MICROSCOPE

BA50&BA80. Educational Environments

Symbio Microscope. L1500 Series. Biological Upright Compound Microscopes. Operating Manual

Huvitz Upright Microscopes

LIVE CELL MICROSCOPE PLATFORM

B-600 Series. infinifix TM B-600. High-end upright laboratory microscopes. High-end upright laboratory microscopes B-600

available with b-350 series Advanced Biological Microscopes for Teachers 27

BA310E ADVANCED BIOLOGICAL MICROSCOPE

Mi50 Inverted Microscope User s Manual. Fein.

POLARIZING MICROSCOPE LPM-A1 Series.

Microscopes. Metallurgical & Materials Upright GXML3030 ROUTINE & RESEARCH. Reflected & Transmitted Light (darkfield reflected) for Materials

Optech microscopes. Routine Lab Applications

OPTIKA. ECOVISION Series. Entry-level biological microscopes for students. Entry-level biological microscopes for students

AE2000. Routine and Live Cell Microscope Solution

S-series T-series. english

Transcription:

B i o l ogical Micro sco p e Biological Microscope ECLIPSE E200

Features exceptionally bright and uniform LED illumination and Nikon s high-quality optics. Ergonomic and user-friendly design ensures years of comfortable and stable use. High-intensity LED Eco-illumination The Eco-illumination provides enough brightness for both phase contrast observation and simple polarizing observation. With a flyeye lens in the illumination system, uniform brightness is provided in the entire field of view. LEDs are environmentally friendly, consume less power than halogen lamps, and last approximately 60,000 hours, reducing costs and the need for frequent lamp replacement. The color temperature does not change when magnification is changed. A halogen illumination model is also available. Fly-eye lens 2

This compact small-sized clinical and laboratory microscope uses high-intensity LED illumination. The long-life LED illuminator is environmentally friendly as it reduces the need for frequent lamp replacement. A halogen illumination model is also available. The ECLIPSE E200 uses Nikon s CFI60 optical system highly-acclaimed infinity corrected optics used in Nikon research microscopes. The result is stunningly sharp and clear images with less chromatic aberration. With the ECLIPSE E200, Nikon has designed a simple and easy-to-use system that reduces fatigue from use over long periods. With a robust structure and anti-mold design*, the ECLIPSE E200 offers high quality and accuracy that can be retained for years even in hot and humid environments. The ECLIPSE E200 offers exceptional operability and durability, and high-quality images. It can be used for various purposes, such as educational, clinical laboratory use and basic research. * Available only with models marketed outside EU member countries ECLIPSE E200-F (model with field diaphragm) ECLIPSE E200 3

Superb infinity optics, plus ergonomic touches optical system The CFI60 optical system combines Nikon s renowned CF optical design with infinity optics to overcome the limitations of the traditional infinity design. CFI60 optics provide longer working distances and higher NA s. These optics deliver startlingly clear images at any magnification because chromatic aberrations and curvature of field are both corrected over the entire field of view when the field number is 20 mm. Nikon developed dedicated CFI E Plan Achromat objectives exclusively for the E200. Also, you can use other highergrade objectives available for the ECLIPSE series whenever your laboratory situation calls for it. Anti-mold design Mold is a formidable enemy of microscopes. Before you know it, it can begin growing on the interior optical surfaces of the microscope and ruin performance. Using anti-mold paint, plus anti-mold agent sealed at critical places inside the microscope, the ECLIPSE E200 is designed to resist mold growth. In tests, an anti-mold treated unit was able to resist the growth of mold for three consecutive years at an average temperature of 30 ºC (86 ºF) and 80 % humidity. * Available only with models marketed outside EU member countries Anti-mold paint and agent 4

Ergonomic design equals comfortable operation Comfort is ensured allowing long hours of use, thanks to Nikon s thoughtful ergonomic design. This is the same design incorporated into Nikon s other laboratory and research-grade ECLIPSE series microscopes. For example, the focus knob and the stage handle are located equidistant from the operator, permitting one-handed operation in a natural posture without twisting the shoulders. Because these controls are low positioned, you can operate the microscope while resting your arms comfortably on the desk. Moreover, the low-profile stage makes exchange of specimen slides easy, while the low inclination angle tube provides comfortable viewing. E200 Conventional models Comparison of the positions of the stage handle and focus control knob Ergonomic binocular tube With this option, users can adjust not only the tube tilt angle, but the eyepiece length to suit their build, eliminating discomfort and strain during long hours of observation. A camera can be attached using the DSC port. *Use of this accessory in combination with other equipment may produce darker images around the periphery. *Must be attached directly to the main body. View angle is adjustable by 10º to 30º. Eyepiece length can be extended by up to 40 mm. E200 configured with an ergonomic binocular tube. Eye-level riser Up to two eye-level risers can be mounted to raise the height of the eyepoint 25 mm each for a total of 50 mm. Robust, vibration resistant construction One-piece construction from arm to base, a stage design where its up/down mechanism is located in the base, plus a wide footprint of 188.5 mm across the back all provide greater rigidity and resistance to vibrations, contributing to superior images. 5

Design ideas that ensure superb optical quality and increased ease of use CFI60 objectives Nikon s exclusive CFI60 objectives provide numerous benefits: longer working distances, high numerical apertures, flat images over the entire field of view with virtually no curvature of field when the field number is 20 mm. To match your laboratory requirements, the E200 provides a wide selection of objectives to choose from. These include the CFI E Plan Achromat objectives developed for the E200 or other higher-grade ECLIPSE series objectives. CFI E Plan Achromat objectives Tube The Siedentopf-type tube is inclined at 30º to ensure comfortable viewing in a natural posture. Designed for use by operators with different builds, this tube has a narrow minimum interpupillary distance of 47 mm, while the eyepoint height can be raised 34 mm when interpupillary distance is 64 mm by simply swinging the front part of the tube up 180º. For extremely tall users, eye-level risers are available to customize the microscope. Low position High position E2-TB Binocular Tube E2-TF Trinocular Tube *Eyepieces are optional. Eyepieces The E200 s eyepieces feature a wider field of view for a microscope of this class and are available in 10X (F.O.V. 20) and 15X (F.O.V. 12) types. These eyepieces also feature built-in diopter adjustment that allows the operator to adjust diopters separately for the right and left easily. In addition, these eyepieces accept measuring reticles that will always be in sharp focus with the specimen. Moreover, they can be locked preventing theft and eliminating the possibility of damage during transit. 6 F.O.V. 20 (E200) F.O.V. 18 (conventional model)

Refocusing stage Nikon has created a unique innovation. The Refocusing Stage eliminates the need to refocus the image manually, making specimen handling safer and easier. In this unique design, the stage can be instantly dropped by pushing it down to exchange specimens or oil the slide, then returns to the original position as soon as the hand is removed. The wide stage surface can accommodate two slide glasses at the same time. In addition, this stage has an array of features including: Increased resistance to vibrations due to the design of the in-base focus mechanism Low-profile design that creates more space around the objective for increased freedom in specimen handling and easier operation A belt-drive mechanism to eliminate the projection of the rack at the edge of the stage for better ergonomics and smoother movement Removable specimen holder for fast hand scanning of slides Improved XY cross travel, providing the comfort and feel similar to Nikon s higher grade ECLIPSE series microscopes Wide stage surface with no rack sticking out of the stage Upper limit stopper When using short-working-distance objectives such as 40X or greater, you can set the upper limit of the stage movement, so that the objective doesn t hit the specimen slide, protecting both from damage. Thanks to this feature, even novices or operators who need to change slides often can perform their job easily and quickly. The limit height can be set in two levels using a stopper bolt either at the standard position or 2 mm lower. This feature is very useful except when extraordinarily thick specimens are used. 2 mm Stage surface Cover glass Slide glass Upper limit (High) Upper limit (Low) Revolving nosepiece A reversed-type nosepiece creates more space at the front of the stage, making handling of specimen slides fast and easy. In addition, the CFI60 optical design eliminates extra optical elements in the nosepiece for enhanced image sharpness. Another advantage of CFI60 objectives is that their increased objective lengths and longer working distances provide more working space around the nosepiece. 7

Condenser Although the stage is low-positioned for comfort, there is ample space around the condenser for easy access. The condenser also features an aperture diaphragm that comes complete with position guide markings for respective E Plan objectives to make operation quick and easy. Safe and easy halogen lamp replacement The E200 comes with a halogen illumination model in addition to a LED illumination model. The lamp is easily replaced by simply opening the lens unit cover and inserting a new one. Field diaphragm model available The E200-F has a built-in field diaphragm that allows the use of Koehler illumination. It features a field lens unit with a field diaphragm that has position guide markings for respective objectives to allow easy setting of optimal apertures. Field diaphragm with position guide markings E200-F 8

A wealth of accessories to broaden the range of microscopic applications Epi-fluorescence microscopy (LED illumination) The E200-dedicated epi-fluorescence attachment, equipped with an LED light source with a minimum lifespan of 10,000 hours, eliminates the need for lamp centering and warming-up time, thus enabling observation immediately after it is switched on. The light intensity can be controlled from a remote controller dial. Up to two LED units from four excitation wavelengths (385nm/470nm/525nm/625nm) can be mounted on the lamphouse, while up to two filter cubes can be mounted on the epi-fluorescence attachment. Eliminating the need of an external transformer facilitates saving space and easy transportation. Epi-fluorescence accessories Phase contrast microscopy/darkfield microscopy Phase contrast observation at 10X, 20X and 2 40X is possible with a single phase annulus slider. The aperture diaphragm automatically 1 opens when the slider is inserted into the condenser. A phase contrast slider for 100X observation is also available. Darkfield observation up to 40X is possible with the E2 Phase Contrast Condenser. 3 4 5 6 1 GIF Filter 2 Centering Telescope 3 E2 Phase Contrast Condenser 4 Phase Contrast Slider 10X-40X 5 Phase Contrast Slider 100X 6 Darkfield Slider CFI Achromat DL objectives for phase contrast Simple polarizing microscopy This method is ideal for observing amyloid and crystals. To set up, install the polarizer over the field lens and the analyzer. Simple polarizing accessories Brightfield microscopy A dedicated Abbe condenser is available for brightfield observation. A blue filter enabling natural color observation can be attached to the condenser. E2 Abbe Condenser 9

Teaching heads Face-to-face and side-by-side teaching heads are available. Digital camera for microscopes When the trinocular tube is used, a digital camera can be attached.* The 5.9 megapixel color microscope camera DS-Fi3 combined with camera control unit DS-L4, enables focusing and viewing of images on the large, 10.1-inch, tablet-type display without the need for a PC. The optimum imaging parameters that match the observation technique in use can be automatically set by selecting the appropriate scene mode icon. Custom modes can also be set. *With a 4X objective, the image may show uneven illumination depending on the camera used. Drawing tube Allows accurate sketching of the image being observed Plastic storage case The rugged, lightweight storage case is handy for transporting and storing the E200. Object marker Allows the point of interest within a specimen to be marked with ink ND filter for objectives (ND3) When this filter is used in combination with a 4X or 10X objective, image brightness can be adjusted to nearly equal to that of a 40X objective. 10

System diagram Camera Adapters C-mount Camera Tubes F C-mount Camera Eyepieces CFI E 10X C-0.7X DXM Relay Lens C-DA C-mount Adapter C-0.55X DS Relay Lens E2-TB Binocular Tube H E2-TF Trinocular Tube H C-TE2 Ergonomic Binocular Tube H C-TEP2 DSC Port for Ergonomic Tube* H CFI E 15X Y-T TV Tube Y-TV 0.55 TV Tube A Intermediate Module Intermediate Module A A C-LEDLH Epi-FL LED Lamphouse E2-FM Epi-Fl Attachment Y-IER Eye-level Riser D B Intermediate Modules Y-THPL LED Pointer Unit A A A Y-IDT Drawing Tube Y-THS Teaching Unit B (Side-by-Side) Y-THSP Support for Side by Side Y-THF Teaching Unit (Face-to-Face) C D C B A P-SA Simple Analyzer D C B A P-SA Simple Analyzer Condensers E ND Filter for Objectives ND Filter for Objectives E2 Phase Contrast Condenser E2 Abbe Condenser CFI60 Objectives CFI60 Objectives Dia Polarizer Blue Filter E E Phase Contrast Slider 10X 40X ECLIPSE E200 Main Body ECLIPSE E200-F Main Body (model with field diaphragm) Phase Contrast Slider 100X Darkfield Slider The E200 and E200-F are available in both LED-illuminated and halogen-illuminated models. * For the DS-Fi3 camera, a C-TEP3 DSC Port C-0.55X for Ergonomic Binocular Tube is recommended 11

Specifications Main body Optical system CFI60 Infinity Optical System, Parfocal distance: 60 mm LED model: High luminescent white LED illuminator (Eco-illumination), Approx. 60,000 hours lifetime, Compliant multi-voltage (100 V-240 V) Illumination Halogen model: 6V20W/6V30W halogen lamp, Compliant multi-voltage (100 V-240 V) Eyepieces (F.O.V., mm) With diopter adjustment CFI E 10X (20) (anti-mold* 1 ) CFI E 15X (12) Coaxial coarse/fine focusing, Right: fine, Left: coarse/fine, Focusing stroke: 26.5 mm, Coarse: 37.7 mm/rotation, Fine: 0.2 mm/rotation, Coarse Focusing motion torque adjustable, Refocusing function (includes self-restoring stage height after pushing down stage) E2-TB Binocular Tube, Inclination: 30, Pupillary distance: 47-75 mm, With eyepiece fixing clamp E2-TF Trinocular Tube, Eyepiece/Port: 100/0, 0/100, 360º rotatable, Inclination: 30, Pupillary distance: 47-75 mm, With eyepiece fixing clamp Tubes (anti-mold* 1 ) C-TE2 Ergonomic Binocular Tube, Eyepiece/Port: 100/0, 50/50 via optional C-TEP2 DSC Port, Inclination: 10 30, Extension: up to 40 mm, Pupillary distance: 50-75 mm, With eyepiece fixing clamp Nosepieces Reversed-type quadruple nosepiece (within main body) Stages Rectangular stage (within main body), with specimen holder, Cross travel: 78 (X) x 54 (Y) mm, Stage size: 222 (W) x 144 (D) mm CFI E Plan Achromat 4X (0.10 / 30) Objectives (NA / W.D., mm) CFI E Plan Achromat 10X (0.25 / 7.0) CFI E Plan Achromat 40X (0.65 / 0.65) (anti-mold* 1 ) CFI E Plan Achromat 100X oil (1.25 / 0.23) CFI Achromat DL and other higher-grade CFI60 objectives can be used. E2 Abbe Condenser NA 1.25, Aperture diaphragm with position guide markings for respective CFI E Plan objectives Condensers E2 Phase Contrast Condenser NA 1.25, Aperture diaphragm with position guide markings for respective CFI Achromat DL objectives Observation methods* 2 Brightfield, Epi-fluorescence, Darkfield, Phase contrast, Simple polarizing E2-FM Epi-fluorescence Attachment, 2 filter cubes mountable, LED illumination (385/470/525/625 nm) Y-THS Teaching Unit B (Side-by-Side) Intermediate attachment* 3 Y-THF Teaching Unit (Face-to-Face) Y-IDT Drawing Tube Y-IER Eye-level Riser Power consumption (max.) Normal value: 3 W (LED model), 41 W (halogen model) Weight (approx.) 7.3 kg (Binocular standard set) *1 Available only with models marketed outside EU member countries *2 Observations except brightfield require optional accessories. *3 Maximum intermediate space 50 mm Dimensional diagram 206.4 101.5 Unit: mm PD = Pupillary distance 191.3 414.6 (When PD is 64 mm) 407.4 (Minimum microscope height) 315 411.4 (Eyepoint height when PD is 64 mm) 381.7 (When PD is 64 mm) 105 188.5 247.7 226.8 Specifications and equipment are subject to change without any notice or obligation on the part of the manufacturer. June 2017 2000-17 NIKON CORPORATION WARNING TO ENSURE CORRECT USAGE, READ THE CORRESPONDING MANUALS CAREFULLY BEFORE USING YOUR EQUIPMENT. Monitor images are simulated. Company names and product names appearing in this brochure are their registered trademarks or trademarks. N.B. Export of the products* in this brochure is controlled under the Japanese Foreign Exchange and Foreign Trade Law. Appropriate export procedure shall be required in case of export from Japan. *Products: Hardware and its technical information (including software) NIKON CORPORATION Shinagawa Intercity Tower C, 2-15-3, Konan, Minato-ku, Tokyo 108-6290, Japan phone: +81-3-6433-3705 fax: +81-3-6433-3785 http://www.nikon.com/products/microscope-solutions/ ISO 14001 Certified for NIKON CORPORATION NIKON INSTRUMENTS INC. 1300 Walt Whitman Road, Melville, N.Y. 11747-3064, U.S.A. phone: +1-631-547-8500; +1-800-52-NIKON (within the U.S.A. only) fax: +1-631-547-0306 http://www.nikoninstruments.com/ NIKON INSTRUMENTS EUROPE B.V. Tripolis 100, Burgerweeshuispad 101, 1076 ER Amsterdam, The Netherlands phone: +31-20-7099-000 fax: +31-20-7099-298 http://www.nikoninstruments.eu/ NIKON INSTRUMENTS (SHANGHAI) CO., LTD. CHINA phone: +86-21-6841-2050 fax: +86-21-6841-2060 (Beijing branch) phone: +86-10-5831-2028 fax: +86-10-5831-2026 (Guangzhou branch) phone: +86-20-3882-0550 fax: +86-20-3882-0580 NIKON CANADA INC. CANADA phone: +1-905-602-9676 fax: +1-905-602-9953 NIKON FRANCE S.A.S. FRANCE phone: +33-1-4516-45-16 fax: +33-1-4516-45-55 NIKON GMBH GERMANY phone: +49-211-941-42-20 fax: +49-211-941-43-22 NIKON INSTRUMENTS S.p.A. ITALY phone: +39-55-300-96-01 fax: +39-55-30-09-93 NIKON GMBH SWITZERLAND SWITZERLAND phone: +41-43-277-28-67 fax: +41-43-277-28-61 NIKON UK LTD. UNITED KINGDOM phone: +44-208-247-1717 fax: +44-208-541-4584 NIKON CEE GMBH AUSTRIA phone: +43-1-972-6111 fax: +43-1-972-611-140 NIKON SINGAPORE PTE LTD SINGAPORE phone: +65-6559-3651 fax: +65-6559-3668 NIKON INSTRUMENTS KOREA CO., LTD. KOREA phone: +82-2-2186-8400 fax: +82-2-555-4415 Printed in Japan (1706-03)T Code No. 2CE-MQZH-7 This brochure is printed on recycled paper made from 40% used material. En