QUICK START GUIDE IC-KP2-*

Similar documents
FACTORY AUTOMATION QUICK START GUIDE IC-KP-*

FACTORY AUTOMATION MANUAL CBX500 HOST INTERFACE MODULES

QUICK START GUIDE 2-D Laser Scanner

FACTORY AUTOMATION. QUICK START GUIDE VBP-HH1-V3.0-V1 AS-Interface Handheld

FACTORY AUTOMATION. MANUAL OHV-F230-B17 PROFINET Gateway for OHV Handheld

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

FACTORY AUTOMATION MANUAL WCS-MBG110 WCS MODBUS RTU INTERFACE MODULE

FACTORY AUTOMATION MANUAL ODZ-MAH-B15-M3

FACTORY AUTOMATION MANUAL MAH* FIRMWARE UPGRADE INSTRUCTIONS

FACTORY AUTOMATION MANUAL PMI360D-F130-IE8-V15 INDUCTIVE POSITIONING SYSTEM

FACTORY AUTOMATION. QUICK START GUIDE IUH-F190-V1-* Read / Write Head for IDENTControl

FACTORY AUTOMATION MANUAL IC-KP-B6-V15B IC-KP-B6-2V15B IC-KP-B6-SUBD

FACTORY AUTOMATION MANUAL PMI360DV-F130-IU2E2- V15

MANUAL Conversion instruction EDM series to VDM100 series

FACTORY AUTOMATION. QUICK START GUIDE OHV200-F22*-B15 Handheld reader

FACTORY AUTOMATION MANUAL VISION CONFIGURATOR

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

MANUAL PCV Parameterization Tool

MANUAL Encoders with J1939 Interface

FACTORY AUTOMATION. MANUAL R CANopen Protocol

QUICK START GUIDE ODT-MAC40*-*-RD

FACTORY AUTOMATION MANUAL CBX800

QUICK START GUIDE ODT-HH-MAH300 Handheld

FACTORY AUTOMATION. CONFIGURATION INSTRUCTIONS WCS3B-LS*** with RS485 interface

FACTORY AUTOMATION. MANUAL IQT1-*-R4-V1 RFID R/W systems, MHz

FACTORY AUTOMATION INSTRUCTION MANUAL. AS-Interface Safety at Work VAA-2E-G4-SN. Version 1.2

FACTORY AUTOMATION INSTRUCTION MANUAL INDUCTIVE POSITIONING SYSTEM -F90

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

FACTORY AUTOMATION. Manual IVI-KHD2-4HD3. Control Unit with 8 Inputs/Outputs

MANUAL PHA...-F200-B6-V15B

FACTORY AUTOMATION TAMING THE POWER F99 SERIES INCLINATION AND ACCELERATION SENSORS

FACTORY AUTOMATION. Manual IVI-KHD2-4HD1. Control Unit

FACTORY AUTOMATION. Manual Speed Monitor KFU8-DW-1.D

FACTORY AUTOMATION MANUAL VBP-HH1-V3.0-V1

FACTORY AUTOMATION MANUAL LS670-DA

FACTORY AUTOMATION. MANUAL VBA-4E3A-G20- ZEL/M1L-P2 AS-Interface Motor Control Module

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

FACTORY AUTOMATION. MANUAL PXV...-F200-B17-V1D Data Matrix Positioning System

MANUAL RFID Supervisor

FACTORY AUTOMATION. MANUAL Absolute Rotary Encoders With EtherCAT Interface

MANUAL Surge Protectors

MANUAL LML-P, LML-S, LML-Ex

PROCESS AUTOMATION. QUICK START GUIDE FieldConnex Diagnostic Manager

MANUAL IPT*-FP with U-P*-RX

PROCESS AUTOMATION. Manual KF!!-UFT-(EX)2.D ROTATION DIRECTION INDICATOR AND CONSTANT SPEED MONITOR

FACTORY AUTOMATION MANUAL IQT-F116-R4-V1 IQT-F116-R4M-V1

MANUAL Installation and Configuration

FACTORY AUTOMATION MANUAL DK12-11-IO PRINT MARK CONTRAST SENSOR WITH IO-LINK INTERFACE

VersaMax IP Input Module

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide

Control Interfaces IDENTControl Control Interfaces IDENTControl Compact Read/Write Heads , 926, 927

FACTORY AUTOMATION. MANUAL Absolute Rotary Encoders Integration into PROFINET

PROCESS AUTOMATION MANUAL. Temperature Trip Amplifier. KFD2-GU-(Ex)1 ISO9001

FACTORY AUTOMATION. Manual Absolute Rotary Encoder for DeviceNet

FACTORY AUTOMATION. MANUAL Absolute Rotary Encoder with PROFIBUS Interface

MANUAL Optical data coupler LS600-DA-IBS

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

FACTORY AUTOMATION MANUAL IC-KP-B6-SUBD. IDENTControl interface with PROFIBUS DP interface

MANUAL HART Multiplexer System

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

Type ME43. Quickstart

FACTORY AUTOMATION. M18 Threaded light beam switches

Dimensions. Electrical connection. Technical data. General specifications Operating frequency. Functional safety related parameters MTTF d

FACTORY AUTOMATION SAFETY LIGHT CURTAINS SLCS AND SLCT SERIES

FACTORY AUTOMATION TAILORED TO YOUR APPLICATION MODULAR SAFETY MONITORING UNIT

FACTORY AUTOMATION. PROGRAMMING SOFTWARE VisoSetup

BNI PBS Z001. IP67 module, Profibus IO-Link Master Short Guide

SCHMIDT Sensor interface PROFIBUS Instructions for use

FACTORY AUTOMATION MANUAL ODT-MAC40*-*-RD

BNI PNT Z015. IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide

FACTORY AUTOMATION. Manual Absolute Rotary Encoder for EtherCAT

Table of Contents. AS-i Modbus Plus-Gateway Table of Contents. 1 Declaration of Conformity The Used Symbols...6

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Quick start guide

6Inclination and Acceleration Sensors

FACTORY AUTOMATION INSTRUCTION MANUAL CONTROL UNIT SC4-2

BNI EIP Z016. IP67 Modules, 8 Outputs BNI EIP Z016 BNI EIP Z016 IP67 Modules, 16 Outputs User s Guide

Assembly Instructions scancontrol 2700/2750 (500)

Dimensions. Electrical connection. Technical data. General specifications Operating frequency. Functional safety related parameters MTTF d

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

Fieldbus Gateway Type ME43

MANUAL AS-INTERFACE Handheld

Dimensions. ø4 (3x) Electrical connection. Technical data. General specifications Operating frequency. Indicators/operating means

FACTORY AUTOMATION. MANUAL ICE1-8DI8DO-G60L-V1D ICE1-8DI8DO-G60L-C1-V1D ICE1-16DI-G60L-V1D Fieldbus Modules with Multiprotocol Technology

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

PROCESS AUTOMATION PROZESSAUTOMATION HANDBUCH MANUAL FREQUENCY CONVERTER HID2891 ISO9001

Dimensions. Electrical connection. Technical data. General specifications Operating frequency. Indicators/operating means. Electrical specifications

MANUAL Functional Safety

PROCESS AUTOMATION MANUAL. Universal Transmitter Power Supply. KF**-CRG2-(Ex)1.D ISO9001

0DQXDO.& &9 6 6 & 3UHVHWWLQJ FRXQWHUV FACTORY AUTOMATION

MGate 5118 Quick Installation Guide

MGate 5105-MB-EIP Quick Installation Guide

FACTORY AUTOMATION MANUAL ODT-HH-MAH120-HD HANDHELD - HIGH DENSITY

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

MANUAL MODULAR SEGMENT PROTECTOR

Serial PROFIBUS Interface

MGate 5111 Quick Installation Guide

MANUAL SEGMENT CHECKER

BNI EIP Z016 IP67 Modules, 16 In-/Outputs User s Guide

PROCESS AUTOMATION MANUAL. Universal Temperature Converter KCD2-UT2-(Ex)1 ISO9001

Transcription:

FACTORY AUTOMATION QUICK START GUIDE IC-KP2-* IDENTControl Compact control interfaces

With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.v.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship"

Contents 1 Introduction... 4 1.1 Purpose of this quick start guide...4 1.2 Product documentation on the internet...4 2 Product Description... 5 2.1 Product family...5 2.2 Connection accessories...5 2.2.1 Connection cable for R/W heads and trigger sensors...5 2.2.2 Cable connectors for the power supply...6 2.2. Connection cable to the Ethernet interface...6 2.2.4 Connection cable to the PROFIBUS DP interface...7 2.2.5 Connection cable to the CC-Link interface...8 2.2.6 Connection cable to the EtherCAT interface...8 Installation... 9.1 Contact protection...9.2 Interface connections...9.2.1 Serial interfaces...9.2.2 PROFIBUS interface...10.2. Ethernet interface...10.2.4 CC-Link interface...11.2.5 EtherCAT interface...12. Power supply...12.4 R/W heads and trigger sensors...1.5 Ground connection...1 4 Commissioning... 14 4.1 Connection...14 4.2 Setting the IP address...14 5 Technical specifications... 16 5.1 Dimensions...16

Introduction 1 Introduction 1.1 Purpose of this quick start guide This quick start guide contains basic instructions for operating the device. However, the manual takes priority over the quick start guide. 1.2 Product documentation on the internet You can view all the relevant documentation and additional information on your product at http://www.pepperl-fuchs.com. Simply enter the product name or model number in the Product/Key word search box and click Search. Select your product from the list of search results. Click on the information you require in the product information list, e.g., Technical documents. A list of all available documents is displayed. 4

Product Description 2 Product Description 2.1 Product family The brand name, IDENTControl, represents a complete identification system. The system consists of an IDENTControl Compact unit with serial interface, inductive R /W heads (125 khz and 1.56 MHz), R / W heads with electromagnetic coupling (UHF with 868 MHz) and accompanying transponders in many different designs. The IDENTControl can be connected to other identification systems. 2.2 Connection accessories 2.2.1 Connection cable for R/W heads and trigger sensors Compatible connection cables with shielding are available for connecting the R/W heads and trigger sensors. Figure 2.1 Accessories Description 2 m long (straight female, angled male) V1-G-2M-PUR-ABG-V1-W 5 m long (straight female, angled male) V1-G-5M-PUR-ABG-V1-W 10 m long (straight female, angled male) V1-G-10M-PUR-ABG-V1-W 20 m long (straight female, angled male) V1-G-20M-PUR-ABG-V1-W Field attachable female connector, straight, shielded V1-G-ABG-PG9 Field attachable male connector, straight, shielded V1S-G-ABG-PG9 Field attachable female connector, angled, shielded V1-W-ABG-PG9 Field attachable male connector, angled, shielded V1S-W-ABG-PG9 Dummy plug M12x1 VAZ-V1-B 5

Product Description 2.2.2 Cable connectors for the power supply Compatible M12 sockets with an open cable end for connecting the IDENTControl Compact to a power supply are available in different lengths. Figure 2.2 Accessories Length 2 m (straight socket) Length 5 m (straight socket) Length 10 m (straight socket) Model number V1-G-2M-PUR V1-G-5M-PUR V1-G-10M-PUR 2.2. Connection cable to the Ethernet interface The IDENTControl Compact has a D-coded, M12 socket and is connected to the network using a suitable cable. Figure 2. Accessories Designation 5 m connection cable V1SD-G-5M-PUR-ABG-V45-G 6

Product Description 2.2.4 Connection cable to the PROFIBUS DP interface The IDENTControl Compact has a B-coded M12 socket and is connected to the network using a suitable cable. Figure 2.4 Accessories Terminator T distributor Y cable Cable with terminator Model number ICZ-TR-V15B ICZ-T-V15B ICZ-T-0.2M-PUR ABG-V15B-G ICZ-2T/TR-0.2M-PUR ABG-V15B-G 1 m cable1) V15B-G-1M-PUR ABG-V15B-G Socket, field attachable Cable connector, field attachable V15B-G V15SB-G Table 2.1 1) Cables are available in the following lengths: 1 m, 2 m, 5 m, 7 m, 12 m, 15 m. Note! The T-distributor is designed for general applications in the PROFIBUS network and is not compatible with the IDENTControl Compact. Always use the Y cable with the IDENTControl Compact. 7

Product Description 2.2.5 Connection cable to the CC-Link interface The IDENTControl Compact has two M12 connectors. It is connected to the bus via standard CC-Link cable with M12 connectors. If you want to exchange the control unit without affecting the bus during operation (hot-plug capability), connect the control unit via a Y-cable to CC-Link IN. Figure 2.5 Accessories Terminator Y-cable Socket M12, field attachable Cable connector M12, field attachable Model number ICZ-TR-V1-110R ICZ-TR-V1-10R ICZ-T-0.2M-PVC-CCL-V1-G V1S-G-ABG-PG9 V1-G-ABG-PG9 2.2.6 Connection cable to the EtherCAT interface The IDENTControl Compact has a D-coded M12 socket and is connected to the network with a suitable cable. Figure 2.6 Accessories Connection cable 5 m Model number V1SD-G-5M-PUR-ABG-V45-G 8

Installation Installation.1 Contact protection Our housings are manufactured using components made partly or completely from metal to improve noise immunity. Read head IDENTControl Compact Danger! Electric shock The metallic housing components are connected to ground to protect against dangerous voltages that may occur in the event of a fault in the SELV power supply! See chapter.5.2 Interface connections.2.1 Serial interfaces Connect the RS 22 and RS 485 interfaces with the M12 socket. You must place the cable shield on the thread in the connector plug. 1 4 2 5 Pin assignment of the M12 socket for RS 22 1 NC 2 RxD GND 4 TxD 5 NC 9

Installation 1 4 2 Pin assignment of the M12 socket for RS 485 1 NC 2 A DGND 4 B 5 NC.2.2 PROFIBUS interface 5 Use the B-coded M12 socket and Y Cable ICZ-T-0.2M-PUR ABG-V15B-G to connect the IDENTControl Compact unit to the PROFIBUS DP. 5 1 4 2 1 VP 2 RxD/TxD-N DGND 4 RxD/TxD-P 5 NC.2. Ethernet interface Use the D-coded M12 socket and the V1SD-G-5M-PUR-ABG-V45-G cable to connect the IDENTControl Compact unit to an Ethernet network. 1 4 2 10 1 Tx+ 2 Rx+ Tx- 4 Rx-

Installation.2.4 CC-Link interface The control interface IC-KP2-2HB18-2V1 occupies 4 sations according to CC- Link. CC-Link IN: M12 connector, A-coded Pin assignment Pin Signal Description 2 1 4 1 SLD Shield 2 DB (white) Data B DG (yellow) Grounding 4 DA (blue) Data A CC-Link OUT: M12 socket, A-coded Pin assignment Pin Signal Description 4 5 1 2 1 SLD Shield 2 DB (white) Data B DG (yellow) Grounding 4 DA (blue) Data A 5 NC not connected Caution! Damage to the control interface and connected slaves It is possible to switch the power socket and the CC-Link IN socket as well as the channel and the CC-Link OUT connector. If the power supply is connected to the CC-Link IN socket, the control interface IC-KP2-2HB18-2V1 and all other slaves connected to CC-Link OUT could be damaged. Terminal resistor Pin assignment Pin Signal Description 2 1 4 1 NC not connected 2 DB Data B NC not connected 4 DA Data A 11

Installation.2.5 EtherCAT interface For the connection of the IDENTControl Compact control interface to an EtherCAT network use the D-coded M12 socket and the cable V1SD-G-5M-PUR- ABG-V45-G. 1 4 2 1 Tx+ 2 Rx+ Tx- 4 Rx-. Power supply Connect the power supply using an M12 connector. A plug with the following pin assignment is located on the housing: 4 1 2 1 + 24 V 2 NC GND 4 NC Compatible connecting cable see chapter 2.2.2 12

Installation.4 R/W heads and trigger sensors You can connect a maximum of two R/W heads (125 khz or 1.56 MHz) or R/W heads with electromagnetic coupling (UHF with 868 MHz) to the IDENTControl Compact. On the two-channel unit, you can connect a trigger sensor to sockets 1 and 2 instead of a R/W head. You can assign the trigger sensor to the R/W head. The trigger sensor must be PNP. socket at housing read/write head trigger sensor trigger switch 2 1 5 4 1 2 4 5 + A - B + signal -.5 Ground connection Connect the IDENTControl Compact unit to ground via a screw on the right under the housing. Note! In order to guarantee safe grounding, mount the serrated washer between the crimp connector and the housing. Use a ground conductor lead with a cross-section of at least 4 mm 2. 1 2 4 1 Housing 2 Serrated lock washer Crimp connector 4 Lock screw Connecting the IDENTControl Compact to ground Screw the ground conductor to the housing with a crimp connector. 1

Commissioning 4 Commissioning 4.1 Connection This section contains information on how to commission the IDENTControl Compact. The example commissioning procedure described relates to the IDENTControl Compact with Ethernet interface. Caution! Uncontrollable triggered processes The plant where the device is installed may be damaged. Before commissioning, make sure that all processes run in a controlled manner. Warning! Incorrect electrical connection Damage to the device or system caused by incorrect electrical connection Check all connections in the plant before commissioning the device. When the supply voltage is connected, the PWR/ERR LED on the device lights up green. If the LED on the device doesn't light up, either the power supply is connected incorrectly or there is a device fault. 4.2 Setting the IP address The IP address of the IDENTControl Compact is preset to 169.254.10.12. The way in which the IP address is modified depends on if you are using a DHCP server. If you are not using a DHCP server, the IP address is manually assigned: Either select the IP address using the rotary switch or start the device with the preset IP address and specify the new IP address on the device website. If you are using a DHCP server, the server assigns the IP address to the IDENTControl Compact. Note! We recommend using a fixed preset IP address in order to avoid system malfunctions. Note! The rotary switch used to select the device address is located on the underside of the IDENTControl Compact. This rotary switch is no longer accessible once the IDENTControl Compact is installed. 14

Commissioning Setting the IP address using the rotary switch 1. Select an IP address. Insert leading zeros so that all the numbers have three digits and then remove the periods. Example: Write the IP address 172.16.10.15 like this: 172016010015. 2. Set the rotary switch to position "F".. Restart the IDENTControl Compact by resetting the power supply. The "ADDR STATE" LED will flash green. 4. Select the first digit of the IP address using the rotary switch and wait until the "ADDR STATE" LED permanently lights up. 5. Select the next digit using the rotary switch and wait until the "ADDR STATE" LED permanently lights up. 6. Repeat this procedure until you have entered all the digits of the IP address. 7. Set the rotary switch to position "0". 8. Configure other network settings in the Network window on the device website (). Entering the IP address on the website The IP address of the PC connected to the IDENTControl Compact must come from the address area 169.254.X.X. 1. Set the rotary switch to position "A". 2. Connect the IDENTControl Compact to a PC via the Ethernet interface.. Restart the IDENTControl Compact by resetting the power supply. 4. Open the IDENTControl Compact website by entering the preset IP address (169.254.10.12) in a browser. 5. Open the Network window. Enter the user name and password (default on delivery: "identcontrol"). Enter the new IP address and configure other settings as required. 6. Set the rotary switch to position "0". 7. Click save. The IDENTControl Compact restarts with the new IP address. For a description of other web functions. Obtaining an IP address from the DHCP server Set the rotary switch to "D" and start the device. The IDENTControl Compact retrieves the network settings from the DHCP server during startup: IP address, subnet mask and gateway address. 15

Technical specifications 5 Technical specifications 5.1 Dimensions 42 16.6 CH1 61.4 6 CH2 107 15 Figure 5.1 Dimensions: IC-KP2-1HB6-V15B IC-KP2-1HB6-2V15B IC-KP2-2HB6-V15B IC-KP2-1HRX-2V1 IC-KP2-2HRX-2V1 IC-KP2-1HB17-2V1D IC-KP2-2HB17-2V1D 16

Technical specifications 42 16.6 5 CH1 61.4 6 CH2 107 15 Figure 5.2 Dimensions: IC-KP2-2HB18-2V1 IC-KP2-2HB21-2V1D 17

FACTORY AUTOMATION SENSING YOUR NEEDS Worldwide Headquarters Pepperl+Fuchs GmbH 6807 Mannheim Germany Tel. +49 621 776-0 E-mail: info@de.pepperl-fuchs.com USA Headquarters Pepperl+Fuchs Inc. Twinsburg, Ohio 44087 USA Tel. +1 0 425555 E-mail: sales@us.pepperl-fuchs.com Asia Pacific Headquarters Pepperl+Fuchs Pte Ltd. Company Registration No. 1990010E Singapore 19942 Tel. +65 67799091 E-mail: sales@sg.pepperl-fuchs.com www.pepperl-fuchs.com Subject to modifications Copyright PEPPERL+FUCHS Printed in Germany 21960 DOCT-1804B_ENG 0/2012