Control systems. Efficient room control

Similar documents
Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green

Decentralised operating and monitoring systems

Single room control system

FCU-MULTI Modbus Fan Coil Unit Controller

HLS34 Modbus FCU/VAV Controllers installation instructions

Key Features and Benefits

Control engineering information VARYCONTROL VAV Units VAV Compact flow rate controller BC0 BF0

CONTENTS CONTROLLERS room controllers room units control units PRODUAL 3 CATALOGUE

5 year. Controllers for comfortable indoor climate and energy efficiency

IQ-MP Gateway. Version apr Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel :

TROXNETCOM AS-i. Modules. Communication interface between a component and the controller. 06/2015 DE/en K

Room Automation Solutions. Freeing up space in building automation.

Commercial Controls. Advanced control for saving time and money

RC-CDTO. Pre-programmed room controller with display, communication and three-point control

Building Energy Management Training Systems

Desigo RXA Room controllers without bus communications Range overview. CA2S3880en_ Building Technologies

CONDUCTOR W4. Installation instruction for W4.1 and W To mount the controller. Controller. Mounting on a DIN rail

FCU-4 FAN COIL CONTROLLER

Pre-programmed room controller with display and communication

Communicative controller for VAV systems

The Bard BrightStat Room Controllers

USER S MANUAL. DAS-G01 The Power of Tomorrow

DESCRIPTION OF MODBUS CONNECTION

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Rittal LCP T3+ High-availability IT cooling with no compromise

FEATURES AND BENEFITS. Installation and operation. Controller

SUPERVISION AND CONTROL FOR HYDRONIC TERMINAL UNITS

BCPro System Product Bulletin

SMART VENTILATION MANAGEMENT: CHANGING THE WAY WE THINK ABOUT VENTILATION

Pre-programmed room controller with display and communication

FCU-4 FAN COIL CONTROLLER

RCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs

gesis FLEX Decentralized room automation Modular Compact Pluggable Room for the future.

Room controller STRA-17

Controllers / Automation Stations U-DDC

Type Differential pressure transducer

Building Technologies. Desigo RXC Room automation system System description. Version 5 and later

DUKE UNIVERSITY DESIGN & CONSTRUCTION STANDARDS

Technical data sheet

Eco Climate Control. Intelligent comfort for radio control of surface heating and cooling systems.

Universal Controller

DEOS Building Automation. Future can be that simple.

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

BELIMO ENERGY VALVE. Transparent energy monitoring with the Belimo Cloud.

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit

Corrigo E. Version 3.0 (ventilation), 3.0 (heating), 1.1 (boiler). Controllers for heating, boiler and ventilation applications in buildings.

RCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012

Smart heating system. with wireless thermostats & smartphone control for every room. Get the most out of any water based underfloor heating

OP10. Pre-programmed, configurable controller for simple applications

Ready for the volumetric flow systems of tomorrow.

RWD68U Universal Controller

The WAGO BACnet Configurator

RCF-230CTD. Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater

SuperWISE II / SuperWISE II SC

AIAS. Technical description

ECLYPSE Series Connected IP and Wi-Fi Product Series and Accessories

Small and Medium Building New and Renovation Prescription Assistance Complete Solution

STRA-17 Room controller. Installation and maintenance manual. Content

Tracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001

RCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005

SCC Inc. TS Series. Technical Instructions. Document No. TS-2000 March 15, 2016

Control components for VAV terminal units

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

Efficient. Innovative. Sustainable.

Temperature controller Ducted systems

IPSUM » COMMISSIONING GUIDE. IPSUM Optimizer IPSUM Connection unit IPSUM Router AIR COMFORT AIR MANAGEMENT IPSUM OPTIMIZATION SYSTEM

Comprehensive Light Management

VAV system solution for non-pressure dependent applications in enclosed spaces

Rack & Enclosure Systems

Andover ContinuumTM. b3850 Series Terminal Controllers

Built-in features Built-in simplicity Built for fans & pumps

Brief description. Type overview

75F Smart VAV with Reheat

7-day room temperature controller

Product Data. SYSTXBBUIZ01 -B EVOLUTIONt ZONE CONTROL. EVOLUTION t ZONE CONTROL

Climatix Sales Presentation. Kurt Steiner / xxx-x-xxx

Satchwell MicroNet. Building Management System MicroNet 50 Series

Weekday / weekend room temperature controller

Building Management Systems (BMS) Back to Basics. Presented By: Andrew Smith Leader Building Technologies A.G. Coombs Advisory

DESIGO RXC The individual room management system Range description CA2S3801E Siemens Building Technologies Building Automation

i-vu Building Automation System VVT Zoning System Total Control and Comfort for Your Building

Semi flush-mounted room temperature controllers with LCD

The Simply Smart Way to Optimize Building Control and Performance

SAUTER equitherm EQJW145/EQJW245. Digital heating controllers for local and district heating networks.

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions

Perfectly in tune. OEM ALPHA 2: System. Tomorrow s smart, room-by-room temperature control

Building Control GAMMA instabus

Leveraging Building Automation Systems to support ongoing commissioning

TAC Xenta 121-FC Programmable Fan Coil Application

Modbus RTU/TCP GOLD RX/PX/CX/SD, GENERATION C/D Applicable to program version 1.05 and newer versions

Semi Flush-mount Room Temperature Controllers with LCD

Brief description. Type overview

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Lighting and Sunblind Control Solution. Open-to-Wireless TM : Wireless, Battery-less Sensing, Wireless Mesh Networks. Energy Management and Metering

Master Panel. Specifications. Document No. TS-2010 February 15, Product Description. Sample Specification

SEZ7000 Series. Wireless Commercial Zoning System

RCF-230CTD. Built-in or external sensor The controller has a built-in sensor. Alternatively, the input for an external PT1000-sensor can be used.

Transcription:

Control systems Efficient room control

AIRCONTROL Efficient room control with X-AIRCONTROL Humidity Occupancy Increasingly demanding requirements on energy efficiency as well as the latest EU regulations have created a need for intelligent control engineering solutions in room air conditioning. To meet these requirements, it does no longer suffice to just look at the room temperature. Equally important factors that influence energy costs include the air quality, occupancy and the damper blade positions of VAV terminal units to control fan speeds according to the system characteristic. Plug and play connections reduce design and engineering efforts and hence also the cost for integrating controls. CO VOC C Excellent solution TROX has combined its know-how from all areas of air distribution technology and developed an energy-efficient overall system. The integration of an X-CUBE air handling unit, volume flow controllers, heating and cooling components, and air-water systems into an overall system offers huge economic and ecological benefits. TROX X-AIRCONTROL replaces an approach that was developed over a long time and in which measurement and control, electronics and air conditioning were treated as completely separate trades, with separate design and construction procedures. X-AIRCONTROL, on the other hand, is a comprehensive system solution that combines trades and allows for a new, innovative strategy. www.trox.de/video-x-aircontrol

Demand-based room control strategies Up with comfort, down with costs The system's main focus is on the individual, demand-based control of air volume flow rate and water circulation for a room. Measuring and evaluating the temperature, air quality, humidity level and occupancy not only improve air quality and comfort in a zone, but also drive costs down. Configuration made easy Using X-AIRCONTROL does not require any programming skills. All you have to do is enter the desired parameters on a web browser interface. Room values are captured by sensors and sent to the controller, which controls the connected components. Room values are transmitted by plug and play. What is more, all data points in the system are matched, which significantly reduces the coordination effort between the various trades. This saves design and installation time and, even more important, costs. X-AIRCONTROL communicates with the central BMS via an Ethernet network with the open standard protocols HTTP, BACnet/IP and Modbus TCP. X-AIRCONTROL Advantages at a glance Individual room control Only one responsible person for each area Less design and commissioning effort Less space required, no conventional switch cabinets Adaptable if room use changes Centralised alarm management and display of actual operating values Optimisation of the air handling unit based on ventilation and air conditioning parameters, ideally with TROX X-CUBE and X-CUBE compact air handling units Ethernet HTTP

System components X-AIRCONTROL zone modules X-AIRCONTROL zone module X-AIRCONTROL zone modules combine information from humidity, air quality (VOC/CO ), temperature and PIR sensors and ensure the perfect interaction of all air handling components in a room. The system recognises all digital sensors automatically and uses measured values to initiate control procedures. No matter what type of system is installed a ventilation system only or a combination with air-water components such as TROX DID, X-AIRCONTROL will always ensure the control optimum. Yet the system does not require any programming by users. VAV terminal unit The zone modules are available in three variants to meet different requirements and be ideally adapted to existing components, such as VAV terminal units or valves. DID active chilled beam Modbus RTU zone module - Modbus interface for peripheral components - Minimal wiring required since a plug-in cable is used for both voltage supply and communication with TROX Compact controllers for variable air volume control (control component BMO-J6) PIR sensor MP bus zone module - MP bus interface for peripheral components - For example, integration of TROX Compact controllers (control component BC0) Valve actuator for floor heating Analogue zone module - 0 0 V interface for peripheral components - For example, integration of TROX Easy controllers for variable air volume control or motorised CAV controllers of Type VFC for constant air volume control Transparent data Control panel with touch display The digital Modbus RTU and MP bus zone modules provide maximum data transparency; for example, they signal damper blade positions to the fans for optimised fan speed control. Sensors for temperature, humidity and air quality 4

X-AIRCONTROL zone master modules X-AIRCONTROL zone master modules allow for expanding the system and provide interfaces to the central BMS and for remote maintenance. They group individual zone modules (e.g. for a floor) and offer a central point for displaying and setting individual zone parameters with the integral web server. Create larger systems by linking several zone master modules Easy connection with plug and play Integral web server for setting and displaying parameters for all connected zone modules Use mobile devices for wireless access (optional WiFi router) Integration into higher level systems 7 day trend logging on SD memory card Special functions for system optimisation X-AIRCONTROL zone master Enclosure The X-AIR-PCASE0V enclosure simplifies installation and commissioning of an X-AIRCONTROL zone module or zone master module. Advantages: X-AIR-PCASE0V as delivered Plastic enclosure with integral transformer - Maintenance-free and CE-certified - 0 V / 4 V AC transformer with micro fuse - To supply voltage to components - Factory wired Mounting bracket - Clicks into place, no tools required - For wall or ceiling attachment No switch cabinet required - Compact design - Decentralised installation of X-AIRCONTROL modules X-AIR-PCASE0V as delivered Click Clicks into place X-AIR-PCASE0V With additional components (by others) zone module / splitter 5

Single room control Stand-alone solution for a zone A single zone module and a room control panel can be used to control a single room. Volume flow control with up to two supply air controllers and one extract air controller Control input signal for heating and cooling units (room temperature control) Timer programmes independent of the central BMS Simple wiring Plug and play connection of components Control panel for setting zone parameters and for temperature recording Control panel Optional sensors To automatically include additional information such as: Occupancy Room air quality VOC or CO Humidity Plug and play connection of components 6

Controlling several rooms Linking individual zones for multi-zone operation An X-AIRCONTROL zone master module can be used to link up to 5 zones. And by adding up to four more master modules, you can expand the system to a total of 5 zones. All zone module variants can be combined as required and simply linked by plug and play. Up to 5 X-AIRCONTROL zone masters Up to 5 X-AIRCONTROL zone modules per master module Up to 5 X-AIRCONTROL zone modules within a network You can easily interconnect even larger areas of a building. Each master module and each zone module is automatically assigned its own address, which facilitates creating a system network enormously. Each zone module controls and maintains the required conditions for the particular room for which it is used. X-AIRCONTROL zone master function overview Fan optimisation based on the damper blade positions of VAV terminal units Setpoint determination for AHU outlet temperature based on local room temperatures (central air conditioning, heating/ cooling) External operating mode default setting and fire alarm contact Allocation of several supply air controllers to an extract air controller Summer/winter compensation Heating/cooling changeover based on flow temperature Chilled water pump control Duct pressure control Plug and play network 00 m max. 00 m max. 00 m max. 4 00 m max. 00 m max. 5...... up to 5 zone modules 7

Connectivity, settings, monitoring Easy configuration with a web browser Using a WiFi router makes configuring the X-AIRCONTROL master and zone modules as well as displaying information a convenient affair. Notebooks, tablets or smartphones the user interface of X-AIRCONTROL has been optimised for mobile devices, offers intuitive navigation and shows all setpoint and actual values on one screen. Ethernet Monitoring the relevant parameters and adjusting them is, hence, easy. It is immediately obvious whether all systems are working normally or if an error requires your intervention. You can select each zone individually for configuration or to adapt it to changing conditions. Advantages Wireless operation with optional WiFi router Intuitive web browser interface (optimised for mobile devices) All relevant setpoint and actual values are available at a glance The web browser interface shows all data. 8

Interfaces and monitoring functions Data points in open standards for connection to AHUs and to the central BMS Ethernet network connection with TCP/IP, BACnet/IP and Modbus TCP/IP protocols Web browser interface for display, configuration and monitoring Setting of individual weekly programmes (scheduling) Remote maintenance is possible Save all zone module settings on an SD card Zone information overview 9

X-CUBE compact with integral zone master The simple solution for smaller projects For smaller projects, i.e. if you want to control only few zones, the ideal solution is to combine X-AIRCONTROL with the X-CUBE compact air handling unit. The X-CUBE compact's integral control system not only provides the control signal to the fan, the dampers and other peripheral components of the compact air handling unit, but also functions as an X-AIRCONTROL zone master. The zone master function of the X-CUBE compact unit allows for integrating up to four X-AIRCONTROL zone modules and hence to individually control the corresponding zones. Plug and play network The Ethernet interface of X-CUBE compact control allows you to access the configuration parameters of both the compact unit and the X-AIRCONTROL zones by simply using a web server. X-AIRCONTROL zone master function is included in X-CUBE compact control Connect up to 4 zone modules of any type Use another zone master to add additional zone modules Use the integral web browser interface for configuration Remote maintenance is possible 4 compact Top performance, small size - For volume flow rates of 600 to 6000 m /h - Maximum energy efficiency 0

X-CUBE The TROX system concept implemented LABCONTROL More and more X-CUBE air handling units are provided with TROX X-CUBE control, offering new options with regard to energy efficiency and trades. If you integrate X-CUBE with other systems, X-CUBE control offers even more functions: TROXNETCOM Monitoring of duct smoke detectors and of up to 6 motorised fire dampers via TROXNETCOM (AS-i) Coordination and logging of maintenance runs for fire dampers Central alarm management The following TROX subsystems send important information to X-CUBE control, which adds to the energy efficiency and comfort: X-AIRCONTROL Signalling of the damper blade positions of all connected VAV terminal units. This allows for conclusions with regard to the system characteristic. Fan control based on the system characteristic saves up to 40% of energy. Information on actual temperature, humidity and air quality allows for an optimisation of the air treatment by the AHU. This minimises the required air transport and improves the overall efficiency at the same time. AIRCONTROL TROXNETCOM CUBE control LABCONTROL As with X-AIRCONTROL, damper blade positions are signalled to control the fans.

Solution overview ) Single room control No zone master required Room control panel for setting and displaying values Single room control - Timer programmes - Temperature control - PIR sensors (optional) - Control based on VOC, humidity (optional) T VOC PIR H ) Control of several rooms Same as ), but: Integration of up to 5 zones per zone master Optional room control panels Central monitoring/parameter setting for zones HTTP BACnet/IP and Modbus TCP/IP interfaces to higher level systems... 5 ) Control of more than 5 rooms Same as ), but: Cascade function for up to 5 zone master modules HTTP Optional room control panels Single room control as well as individual sensor and unit configuration Can be expanded to 5 modules... 5 Key... 5 Plug and play network...5 Ethernet network... 5

4) Control of up to 4 rooms with X-CUBE compact control Up to 4 zone modules can be connected 4 Same as ), but: X-CUBE compact control includes zone master for up to 4 zone modules Web browser on integral X-CUBE compact display Easy energy optimisation of the entire system For example, fan control based on damper blade positions of VAV terminal units 5) Control of several zones with X-CUBE control Same as ), but: HTTP Easy energy optimisation of the entire system For example, fan control based on damper blade positions of VAV terminal units...5...5 Centralised air conditioning (heating/ cooling) based on actual room temperatures and VAV terminal units...5...5 6) Control of several zones with central BMS (by others) HTTP Same as ), but: Use of standard interfaces of X-AIRCONTROL for integration with higher level systems Display and operation with web browser, X-TAIRMINAL or by others...5...5...5...5

Comfort conditioning in the STYLES Hotel, Piding STYLES Hotel in Piding a successful X-AIRCONTROL project STYLES Hotel, Piding, Germany This design budget hotel has 07 guest rooms, conference rooms and a large restaurant. TROX has supplied the entire air conditioning and fire protection system, which consists of VAV terminal units, X-AIRCONTROL zone modules and zone masters, a TROXNETCOM control system including smoke detectors and fire dampers, as well as two X-CUBE air handling units and the central X-TAIRMINAL software. The comfort of guests was a priority from the start. Air management and fire protection were of particular importance to the owners of the design budget hotel. X-AIRCONTROL zone modules provide a pleasant climate in the various areas of the hotel, i.e. in guest rooms, conference rooms and the restaurant. Zones were grouped for each floor and connected to a zone master module, then connected to the X-CUBE air handling units. Guest room with an X-AIRCONTROL zone module Hotel mode At a previously set time, the temperature setpoint for a room is reset to a previously defined value, and the operating mode for the zone is reset to AUTO. In other words, you can define different setpoints for different rooms; guests can manually adapt the room temperature, but AUTO mode will resume eventually, which reduces energy consumption. Restaurant Conference room Hotel mode control 4

Intelligence built into the system X-TAIRMINAL Complete system overview There is hardly a type of building with such a variety of rooms as a hotel. Whether suites, meeting rooms, spa or restaurants the indoor conditions have to be constantly adapted to the number of occupants and to the individual comfort requirements of the guests. To help the system owner to monitor energy consumption and system operation in general at all times, and to see trends that may be used to adapt parameters, the TROX X-TAIRMINAL software has been installed. Immediate clarity: the TROX X-TAIRMINAL software The STYLES Hotel is in fact equipped with several TROX systems that run in parallel, e.g. TROXNETCOM for fire and smoke protection, and X-AIRCONTROL for room control. X-TAIRMINAL provides users with a complete overview of all systems on one screen. Users can display system values, alarms or trends centrally. Reception area X-TAIRMINAL allows users to display and analyse all parameters for a ventilation and air conditioning system, for example to recognise trends. 5

TROX GmbH DE/en TROX GmbH Heinrich-Trox-Platz 47504 Neukirchen-Vluyn Germany Phone +49 (0) 845 00 trox@trox.de www.troxtechnik.com SF/08/04/X-AIRCONTROL/DE/en Subject to change All rights reserved