Acknowledgments. Ping Xia, Ph.D., UCSF. Pam Akazawa, CMD, UCSF. Cynthia Chuang, Ph.D., UCSF

Similar documents
Disclosure. Outline. Acknowledgments. Ping Xia, Ph.D., Page 1. LINAC and MLC QA for IMRT. Received research support from Siemens Medical Solutions

Volumetric Modulated Arc Therapy - Clinical Implementation. Outline. Acknowledgement. History of VMAT. IMAT Basics of IMAT

Facility Questionnaire PART I (General Information for 3DCRT and IMRT)

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE

IMRT and VMAT Patient Specific QA Using 2D and 3D Detector Arrays

Photon beam dose distributions in 2D

The MSKCC Approach to IMRT. Outline

Basic Radiation Oncology Physics

8/4/2016. Emerging Linac based SRS/SBRT Technologies with Modulated Arc Delivery. Disclosure. Introduction: Treatment delivery techniques

FAST, precise. qa software

Data. ModuLeaf Mini Multileaf Collimator Precision Beam Shaping for Advanced Radiotherapy

Qalitätssicherung an Multileafkollimatoren. Dr. Lutz Müller Würzburg jan 2004

Tomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS

Advanced Radiotherapy

ICARO Vienna April Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588

Monaco VMAT. The Next Generation in IMRT/VMAT Planning. Paulo Mathias Customer Support TPS Application

7/29/2017. Making Better IMRT Plans Using a New Direct Aperture Optimization Approach. Aim of Radiotherapy Research. Aim of Radiotherapy Research

TPS COMMISSIONING. Laurence Court University of Texas MD Anderson Cancer Center 4/3/2017 1

Machine and Physics Data Guide

Acceptance Testing and Commissioning of Monte Carlo Dose Calculation Systems. Bruce Curran University of Michigan Medical Center Ann Arbor, MI

4 Measurement. and Analysis. 4.1 Overview and Underlying Principles 4-1

A SYSTEM OF DOSIMETRIC CALCULATIONS

Dynalog data tool for IMRT plan verification

7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC

Transitioning from pencil beam to Monte Carlo for electron dose calculations

THE WIRELESS PHANTOM PERFORM ACCURATE PATIENT QA IN LESS TIME THAN EVER!

Monte Carlo methods in proton beam radiation therapy. Harald Paganetti

3DVH : SUN NUCLEAR On The Accuracy Of The corporation Planned Dose Perturbation Algorithm Your Most Valuable QA and Dosimetry Tools *Patent Pending

Using a research real-time control interface to go beyond dynamic MLC tracking

IAEA-TECDOC-1583 Commissioning of Radiotherapy Treatment Planning Systems: Testing for Typical External Beam Treatment Techniques

Dosimetric impact of the 160 MLC on head and neck IMRT treatments

Assesing multileaf collimator effect on the build-up region using Monte Carlo method

Creating a Knowledge Based Model using RapidPlan TM : The Henry Ford Experience

Raising the Bar in IMRT QA

Dose Distributions. Purpose. Isodose distributions. To familiarize the resident with dose distributions and the factors that affect them

NEW METHOD OF COLLECTING OUTPUT FACTORS FOR COMMISSIONING LINEAR ACCELERATORS WITH SPECIAL EMPHASIS

A secondary monitor unit calculation algorithm using superposition of symmetric, open fields for IMRT plans

Hugues Mailleux Medical Physics Department Institut Paoli-Calmettes Marseille France. Sunday 17 July 2016

8/2/2017. PerFRACTION from Sun Nuclear Automated Transit Dosimetry for In-Vivo QA

Real-time monitoring of linac performance using RT plans and logfiles

Radiation therapy plan checks in a paperless clinic

ViewRay System Commissioning

Quick Reference Datasheet For All RIT113 Packages

Radiation therapy treatment plan optimization

Use of Monte Carlo modelling in radiotherapy linac design. David Roberts, PhD Senior Physicist Elekta

ADVANCING CANCER TREATMENT

Delta 4 PT. True Volumetric Pre-treatment Verification. The difference is clear

Preface. Med. Phys. 35(9), , Mechanical QA. Radiation Survey Mechanical tests Light radiation Table, Collimator, Gantry Jaws.

Clinical implementation of photon beam flatness measurements to verify beam quality

TomoTherapy Related Projects. An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram

IMRT site-specific procedure: Prostate (CHHiP)

The IORT Treatment Planning System. radiance. GMV, 2012 Property of GMV All rights reserved

ADVANCING CANCER TREATMENT

A comparative analysis for verification of IMRT and VMAT treatment plans using a 2-D and 3-D diode array

Radiotherapy Plan Competition TomoTherapy Planning System. Dmytro Synchuk. Ukrainian Center of TomoTherapy, Kirovograd, Ukraine

Calibration and quality assurance for rounded leaf-end MLC systems

DAILY LINAC QA BEAM QA

A method for determining multileaf collimator transmission and scatter for dynamic intensity modulated radiotherapy a

Analysis of Radiation Transport through Multileaf Collimators Using BEAMnrc Code

Image Quality Assessment and Quality Assurance of Advanced Imaging Systems for IGRT. AAPM Penn-Ohio Chapter Sep 25, 2015 Soyoung Lee, PhD

VMAT for dummies: Concepts, Clinical Implementation and Treatment Planning. Rajat Kudchadker, Ph.D. Associate Professor

Chapter 9 Field Shaping: Scanning Beam

Computational modelling and analysis: IOP Medical Physics Group

Independent monitor unit calculation for intensity modulated radiotherapy using the MIMiC multileaf collimator

Verification of dynamic and segmental IMRT delivery by dynamic log file analysis

A DOSIMETRIC MODEL FOR SMALL-FIELD ELECTRON RADIATION THERAPY A CREATIVE PROJECT (3 SEMESTER HOURS) SUBMITTED TO THE GRADUATE SCHOOL

How would, or how does, the patient position (chin extended) affect your beam arrangement?

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 7, NUMBER 3, SUMMER 2006

Initial Clinical Experience with 3D Surface Image Guidance

Measurement of depth-dose of linear accelerator and simulation by use of Geant4 computer code

Table of Contents. About AQUA

Feasibility of 3D Printed Patient specific Phantoms for IMRT QA and Other Dosimetric Special Procedures

URGENT IMPORTANT FIELD SAFETY NOTIFICATION

Secondary 3D Dose QA Fully Automated using MOSAIQ's IQ Engine. MOSAIQ User Meeting May Antwerp

Goals. Scope/exclusions. Outline: follow outline of MPPG (plus rationale & some implementation experiences)

UNCOMPROMISING QUALITY

Tumor motion during liver SBRT

Ini$al Performance Test Results on an Elekta MR-Linac

Modulation factors calculated with an EPID-derived MLC fluence model to streamline IMRT/VMAT second checks

Version 3.7. User Manual

TEPZZ Z754_7A_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (51) Int Cl.: A61N 5/10 ( )

A Geant4 based treatment plan verification tool: commissioning of the LINAC model and DICOM-RT interface

1. Learn to incorporate QA for surface imaging

Verification of dose calculations with a clinical treatment planning system based on a point kernel dose engine

GPU applications in Cancer Radiation Therapy at UCSD. Steve Jiang, UCSD Radiation Oncology Amit Majumdar, SDSC Dongju (DJ) Choi, SDSC

ROBUST OPTIMIZATION THE END OF PTV AND THE BEGINNING OF SMART DOSE CLOUD. Moe Siddiqui, April 08, 2017

Development a simple point source model for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code

Commissioning and verification of the collapsed cone convolution superposition algorithm for SBRT delivery using flattening filter-free beams

REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT

Monte Carlo Methods for Accelerator Simulation and Photon Beam Modeling

Version 5.6. Quick Start Guide

Dose Calculation and Optimization Algorithms: A Clinical Perspective

Determination of primary electron beam parameters in a Siemens Primus Linac using Monte Carlo simulation

Monaco Concepts and IMRT / VMAT Planning LTAMON0003 / 3.0

Feasibility study of performing IGRT system daily QA using a commercial QA device

Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers

Three-dimensional IMRT verification with a flat-panel EPID

An Investigation of a Model of Percentage Depth Dose for Irregularly Shaped Fields

Thank-You Members of TG147 TG 147: QA for nonradiographic

Transcription:

Page 1 Quality Assurance of IMRT Delivery Systems - Siemens Lynn J. Verhey, Ph.D. Professor and Vice-Chair UCSF Dept. of Radiation Oncology AAPM 22 Annual Meeting, Montreal Acknowledgments Ping Xia, Ph.D., UCSF Pam Akazawa, CMD, UCSF Cynthia Chuang, Ph.D., UCSF William Wara, MD and his excellent physician staff in UCSF Dept. of Rad. Onc. Siemens Medical Systems, Concord, CA NOMOS Corporation, Sewickley, PA Introduction IMRT delivery requires special quality assurance due to: Small number of MUs per field Large number of small fields Need to investigate several beam properties in detail: Dose linearity Beam flatness and symmetry MLC properties to investigate: Leaf leakage for closed pairs and leaf-to-leaf Leaf position accuracy and offset Introduction (con t) Assumption of inverse-planned IMRT Relatively complex plans (e.g., H/N) currently result in 1-2 beam segments per beam direction (CORVUS by NOMOS) Properties of and beam delivery control system, affect the quality assurance methods Issues of Quality Assurance Machine related QA Dose linearity Field symmetry and flatness Leaf position accuracy Dose accuracy of each segment Patient related QA Measure phantom plans Check Intensity map Patient position verification Dose to point i Inverse Planning Problem D i = x 1 d 1i + + x J d Ji = x d i The dose deposited to the ith point in the body from the jth ray is linearly related to the intensity of that ray i x j organ target Inverse Treatment Planning 35 55 125. Nasopharynx Prescription requires dose goals for target and normal tissues (possibly 3-point DVHs) Planner chooses beams and no. of intensity levels Opportunity to place margins between CTV and PTV Objective function minimized using penalties based on clinical input Output is discrete or continuously varying intensity profiles for each defined beam direction and MLC segments and weights for accelerator of choice Many commercial systems now available (CORVUS, Helios, Helax, Pinnacle, CMS, KonRad) 27 235 125 9 % Volume 1. 75. 5. 25.. 2 Dose (cgy) 4 GTV/IMRT GTV/3D Cord/IMRT Cord/3D 6 8

Page 2 % Volume 125. 1. 75. 5. 25.. 2 Nasopharynx 4 Dose (cgy) Rt. Parotid/IMRT Rt. Parotid/3D Chiasm/IMRT Chiasm/3D 6 8 Conclusions from Nasopharynx Comparison Dose to cord limits GTV dose for 3D plan Significantly better cord sparing with IMRT plan than with 3D plan Significantly better parotid sparing with IMRT than with 3D plan Typically need approximately 12-14 segments over 7-9 directions for good conformality in H/N treatments Frequency 8 6 4 2 Nasopharynx Case -.5 1.5 3.5 5.5 7.5 9.5 11.5 13.5 MU/Seg. Rx technique: 15 gantry angles, 1 intensity levels, total # of segments = 491 is this really necessary? Siemens Double Focused MLC SOURCE Properties Upper Jaw Lower Jaw MLC Focused in Y Focused in X Doubly focused, effective arc motion 27 leaf pairs projecting to 1 cm, 2 leaf pairs at extremes projecting to 6.5 cm Conventional field size 4 x 4 cm IMRT field size 28 long x 21 wide determined by overtravel limits of MLC (1 cm) and y-jaw (1 cm) Interdigitation of leaves not allowed Closure of leaf pair possible No velocity control, only step-and-shoot Issues of Quality Assurance Machine related QA Dose linearity Field symmetry and flatness Leaf position accuracy Dose accuracy of each segment Patient related QA Measure phantom plans Check Intensity map Dose Linearity Check In theory, radiation dose is linear, but because of end effect, this linearity may not be strictly true Step and shoot IMRT delivery introduces many small MU segments. Dose linearity should be verified using IMRT delivery technique with small MUs Dose Linearity Check Siemens Linacs: - Measured a point dose using an ion chamber for an IM square field, consisting of 99, 15x15 cm 2 segments with 1MU /seg - Compared with that of a regular 15x15 field delivered with 99 MU - Special soft pots can be adjusted to achieve better dose linearity

Page 3 Results of Linearity Check Total MU MU/Seg Energy Reading (%) 99 99 6MV.475 99 1 6MV.475 1. 99 99 18MV.478 99 1 18MV.4844 1.3 KD-2, Dmax, 1 cm SSD, 15x15 cm 2 Dose Linearity Check Varian Linacs: - Measured point doses of special IM field consisting of 19 and 95, 15x15 cm 2 segments with.1 MU/seg.2 MU/seg, and 1 MU/seg, respectively. - Programmed with stop and shoot delivery - Purposely programmed 2 mm shift between segments to simulate beam on and off - Compared with the results of regular 15x15 cm 2 field with 19 MU and 95 MU respectively Results of Linearity Check Total MU # of Seg MU/seg Reading (%) 19 1 19.95 19 19.1.94 -.7 38 1 38.184 38 19.2.185.6 95 1 95.4523 95 19.5.4517 -.19 95 95 1.4525 -.5 CL_23, 6MV, 1.5 cm depth, 1 cm SSD, 15x15 cm 2 Results of Linearity Check Total MU # of Seg MU/seg Reading (%) 19 1 19.934 19 19.1.933 -.11 38 1 38.1863 38 19.2.1864.4 95 1 95.4657 95 19.5.4658.4 95 95 1.4656.1 CL_23, 18MV, 3.2 cm depth, 1 cm SSD, 15x15 cm 2 Field Symmetry and Flatness Check Field symmetry and flatness are tuned through a feedback loop from the internal ion chambers. Small MU delivered to each segment may affect the field symmetry and flatness Conventional profile measurement can not be used because of insufficient MUs. The ion chamber is placed at following symmetry points (+5, +5), (+5, -5), (-5, +5), and (-5, -5) in a 15 x 15 cm 2 field delivered in IMRT fashion. Results of Symmetry and Flatness (,) 99 99.475 (,) 99 1.475.96 (-5, 5) 99 1.4853 3.15 (-5, -5) 99 1.4889 3.91 (5, 5) 99 1.481 2.4 (5, -5) 99 1.4836 2.78 KD2, 6MV, 1.5 cm depth, 1 cm SSD, 15x15 cm 2 Results of Symmetry and Flatness (,) 99 99.478 (,) 99 1.4844 1.34 (-5, 5) 99 1.56 4.73 (-5, -5) 99 1.529 5.21 (5, 5) 99 1.516 4.94 (5, -5) 99 1.4981 4.21 Results of Symmetry and flatness (,) 19 19.95. (,) 19.1.94 -.1 (-5, 5) 19.1.918 1.4 (-5, -5) 19.1.912.8 (5, 5) 19.1.916 1.1 (5, -5) 19.1.912.8 Results of Symmetry and Flatness (,) 19 19.934. (,) 19.1.933.11 (-5, 5) 19.1.92 1.52 (-5, -5) 19.1.915 2.3 (5, 5) 19.1.913 2.25 (5, -5) 19.1.92 1.5 KD2, 18MV, 3.2 cm depth, 1 cm SSD, 15x15 cm 2 CL_23, 6MV, 1.5 cm depth, 1 cm SSD, 15x15 cm 2 CL_23, 18MV, 3.2 cm depth, 1 cm SSD, 15x15 cm 2

Page 4 MLC Leaf Position Check and Field Penumbra MLC leaf position accuracy and field penumbra become more important in IMRT treatment, because it can affect dose through the entire field as the multiple segments abutting together, not just on the edge of the field as in conventional delivery Leaf position accuracy for Siemens and Varian Linacs meets their specifications Leakage after calibration Leakage without calibration Intensity pattern showing need for calibration Multileaf Collimator Designs after calibration without calibration 2. cm strip, systematic gap 2.1 cm strip, some gap (.5 mm offset per leaf) Each manufacturer has a different design for their MLC Location, leaf width, and leaf end design Single focused or double focused Restrictions on motion (path, over-travel, interleaf) Field size These factors have an impact on dose delivery and must be considered in treatment planning Rounded Leaf End vs Penumbra Elekta MLC System Targ et Varian MLC System Primary collimator Varian X1 Y1 Ion chamber Filter Upper Jaw MLC Tertiary X2 2.3 HVT (a) (b) R eflector Wedge MLC Leaf A i Leaf B i 2.3 HVT Leaf Leaf Y back-up diaphragm y1 n -12.5 CM 1 2 CM X Diaphragms xa i,n xb i,n y2 n A daptor Ring Lower Jaw x1 n x2n

Page 5 4 cm Leaf Motion Constraints 4 cm Varian 14.5 cm Interleaf motion (Varian) No Interleaf motion (Siemens) 3. cm 2 cm 25 cm 32.5 cm Siemens Elekta 4 cm 14.5 cm 29 cm asymmetric jaw 4 cm Minimum Gap (Elekta) MLC Field Size for IMRT Linac IMRT Field Size Nominal Field Size Varian 29 x 26 (4) cm 2 4 x 26 (4) cm 2 (2 x 14.5 cm) Siemens 21 x 2 (27) cm 2 4 x 27 (4) cm 2 Elekta 25 x 25 cm 2 4 x 4 cm 2 Siemens SMLC-IMRT Delivery System Automatic field sequencing system (Primeview/SIMTEC) For both conventional and IMRT delivery Automatically deliver all gantry angles including segments in each IM field Supports step and shoot SMLC delivery ~ 5-6 sec. R/V overhead per segment Treat 1-12 segments in 2 minutes Only integer MU can be specified per segment Supports network RTP Dosimetric Verification Procedures at UCSF * In the beginning, dosimetric verification was performed prior to each patient s first treatment using solid water phantom with ion chambers and film (Results - The measured point doses near the maximum were all within 5% of predicted doses) * Now designing system for q/a checks using cylindrical plastic phantom with multiple holes for MOS-FET dosimetry. Will move to this method in the future. IMRT Verification 1.6 MOSFET Consistency 14 MOSFET Linearity Difference (%) 1.4 1.2 1.98.96.94.92.9.88.86 1 3 5 7 9 11 13 15 17 19 21 23 25 # of Patients 27 29 31 33 35 37 39 41 4. MOSFET1 MOSFET2 MOSFET3 3. 2. 1.. -1. -2. -3. -4. 2 4 6 8 1 12 14 16 18 2 Number of Measurements Figure 5 MOSFET Readings MOSFET1 MOSFET2 12 MOSFET3 MOSFET4 1 8 6 4 2 1 2 3 4 Radiation (cgy) Figure 6

Page 6 Percent Depth Dose Comparison 1.2 1 Ion Chamber MOSFET 2. 1.5 Angular Dependence a Calc. 2.18 Gy Meas. 2.9 Gy Diff 4.35% Calc..82 Gy Meas..86 Gy Diff 4.63% c Percentage (%) Percentage (%).8.6.4 1..5. -.5-1. -1.5 b Calc. 1.37 Gy Meas. 1.42 Gy Diff 3.52% Calc..81 Gy Meas..78 Gy Diff 3.45% d.2-2. -2.5 5 1 15 2 25 3 35 Depth (cm) -3. 2 4 6 8 1 12 14 16 18 Degrees Figure 7 Figure 8 Figure 1 Dosimetric Verification- Results Observations independent of delivery system High dose regions of plan (typically >85% max) were generally within 2% of calculated Lower dose regions (typically planned for 3-5 % of max) were 1-15 % higher than planned In general, higher complexity (more intensity levels and segments) gave higher discrepancies Dosimetric Verification - Interpretation Dose discrepancies approximately the same for plans delivered with Siemens and Varian accelerators - i.e., independent of dose delivery system Probable cause is dose calculation algorithm within planning system which does not deal well with small fields and leaf transmission and scatter - soon Monte Carlo can answer question Dose errors due to DMLC control delays probably not clinically significant though more research needed What have we learned so far with our IMRT experience? There is no perfect system limitations of planning system, IMRT delivery system and dose verification must be considered Clinical needs drive us to complex IMRT plans (many fields and segments) therefore, delivery speed is important Dose accuracy not as good for high complexity due to large numbers of small fields and small dose per segment IMRT field length and field width requirements can limit use Current Limitations with use of IMRT for Precision H/N Radiotherapy Patient immobilization and target localization 3D dose verification Treatment parameter verification Control of optimization process Efficient registration of biological imaging to Rx planning CT Accelerator control system efficiency MLC leaf positioning accuracy Dose calculation accuracy Dose delivery technology Patient immobilization and target localization Dose gradients for IMRT are large in all directions so immobilization and target localization even more important than for 3DCRT Work in progress includes: Imbedded markers, use of portal imagers and automated search routines to localize targets Image subtraction for video images of patient vs. setup Couch motions activated to reposition correctly on a daily basis using feedback CT in treatment room (or on gantry) to verify plan before treatment Motion prevention such as gated therapy for lung and thorax tumors Lateral Head & Neck 6 MV images acquired with Am-Si Flat Panel 2 MU Localization image Verification image

MKR 3 MKR 1 MKR 2 Page 7 Automated Radioopaque Marker Detection Target Alignment 3-D Dose Verification Courtesy of Jean Pouliot, Ph.D. and 9 port films are digitized into a PC with ISOLOC, the localization software preference, NMPE Inc. ISOLOC calculates target location and necessary moves to bring the target to the isocenter Magnified lenses clearly display readouts of submillimeter accuracy. The preference micropositioner is used to dial-in the moves Can only do single point or plane (film) dose verification at this time In the future: Bang Gels read out by MR Instrumented phantoms with multiple fixed points using diodes or very small ion chambers or MOS- FET (This is UCSF choice) Portal imagers to image transmitted dose and programs to back-project information to patient MV-CT using treatment beam Treatment parameter verification Difficult to verify set of MLC position information for IMRT treatments In the future: Use portal imagers to image intensity pattern and to verify MLC positions on the fly Special programs to verify MU calculation per beam segment Intensity Pattern Verification for IMRT Delivery Individual beam segments Reconstructed intensity map Dose calculation accuracy Currently, inverse planning programs have very simple dose calculation algorithms due to requirements of speed In the future: Multiple calculation algorithms will be available to check plan during optimization process Monte Carlo dose calculation program will become routinely available to evaluate the optimized plan Speed of Monte Carlo will become so fast that it can be done during the optimization process (CORVUS will incorporate Peregrine Monte Carlo dose algorithm in the near future) Workload - IMRT vs. 3DCRT Comparisons recently made of physics effort and treatment times for IMRT vs. 3DCRT for complex treatment plans Physics times were on average a factor of 2-3 higher than for 3DCRT (8 hours vs. 3 hours) IMRT treatment times somewhat longer on average than for 3DCRT (2-45 vs. < 15 min) Physician time somewhat greater for IMRT, mostly due to target contouring time (not documented) UCSF Experience with IMRT- Conclusions to date Routine Monte Carlo calculations of expected dose distributions will be available in very near future with Peregrine and other programs Portal imager will soon be able to provide rapid, high contrast images to help verify patient and/or target position automatically Linac manufacturers working hard to make IMRT faster and dose delivery more accurate IMRT still not simple enough to be used in all clinics, but we are on the right track