Copyright Oregon RFID, Inc.

Similar documents
Model AXIZ SB-1 User Manual. Destron Fearing Corporation 490 Villaume Ave. South St. Paul, Minnesota

DISCLAIMER Whilst every effort has been made

AI3100 Portable Reader User Manual

AI4100 Portable Reader User Manual

2.4GHz Digital Wireless 7 LCD Surveillance Kit

8-1. This chapter explains how to set and use Data Sampling.

Updating the operating system and BONGO (MCU) firmware

THUNDERBIRD INSTRUCTIONS HAND HELD ELECTRONIC TAG READER MODEL PR20

MICRO-1356 MULTI-PROTOCOL READER

I-Dent Marker Communications for 186 CPU Firmware Versions 1 and 2

ELITE READER GETTING STARTED GUIDE

Model IMP-22G2,H Low Cost Slave Clock Impulser Converts your slave clock to a working timepiece without modifying its original mechanism.

User s Manual. Attention

BaracodaManager (Pocket PC)

AbraScan Test Strip Reader Digital Reading of Test Strips for the Determination of Cyanotoxins in Contaminated Water Samples

battery icon in the bottom right corner of the display screen.

STANDALONE INTERFACES USB-DMX 512 & 1024 CHANNELS V.1.1

Welcome Contents Diagram

MMA845xQ Sensor Toolbox User s Guide

Help Guide. Getting Started. Making connections. The following explains how to use this speaker. Select a topic from the navigation pane.

AKELA Vector Network Analyzer (VNA) Quick Start Guide

DVK User Manual. Scope. Related Melexis Products. Introduction

InfoTag KE28xx Communications for 186 CPU Firmware Version 4

CHC HCE320 GNSS Data Controller User Guide

Tablet PC User Manual

ENGLISH. Inductive Guard Tour Reader User s Manual BP-2002 BP-2002-W BP-2002B BP-2002B-W. BP-2002 Serial Product

User s Manual. Xpad 82

This handbook contains important security measures and product information, to help avoid accidents. Please

SyncBreeze FILE SYNCHRONIZATION. User Manual. Version Dec Flexense Ltd.

MODEL SUB Manual

Metal Guard Tour Terminal. Manual Part Number : TM REV : 01 November 2004 GIGA-TMS

IronSync File Synchronization Server. IronSync FILE SYNC SERVER. User Manual. Version 2.6. May Flexense Ltd.

Opera 5. User manual. Version 1.15

Measuring Border Delay and Crossing Times at the U.S./Mexico Border

The Pipe Reader. Please read this Instruction Manual

The leg stand is located at the back of the product, on the top right. This adjustable-length leg stand will allow your ARCHOS to stand by itself on a

PADPULS2 M-BUS Pulse Input Modules

OPN2005 / PX20 Bluetooth Demo Manual Version RFL /7/2013 Opticon Sensors Europe BV

DT6I Series 2 INTERROGATABLE 6 CHANNEL TALKING DIALLER. INSTALLATION MANUAL 2 nd EDITION.

Using AORUS Notebook for the First Time

Application Note Demonstrating the Serial Port Profile (SPP) Between BlueConnect and BTW 2002/5/29

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

Axon HD Content Management Application (CMA)

Content Management Application (CMA)

SYRDBT. SYRIS Handheld bluetooth RFID Reader

FERGUSON BEAUREGARD. RTU-5000 Configurator User Manual

12-CHANNEL TEMPERATURE RECORDER WITH EXCEL-FORMATTED DATA LOGGING SD CARD USER S MANUAL

TFA. KlimaLogg Pro. User Manual. Revision: 1.1

SNMP Web Management. User s Manual

USER MANUAL LIVESTOCK ID GES3S PORTABLE READER AND DATA COLLECTOR. Version 1.6. Corporate Headquarters:

INTERFACE & SOFTWARE GUIDE

Overview 1. Foreword 2. Warnings

Raytheon Senior Project Test Plan Spring 2012

Encompass 1i Handheld Reader Display Only Version User Manual

Hand-Held Inspection Device. Quick Start User Guide

H A N D O U T : T R O U B L E S H O O T I N G L A P T O P S

IS-DEV KIT-9 User Manual

Using GIGABYTE Notebook for the First Time

Intuition ReAct Content Manager PC Application

M2500 Engine Controller Configuration Manual

DNP 3.0 & Modbus SCADA INTERFACE INSTRUCTIONS FOR 205T BASED SYSTEMS

Manual. LibAssist ( )

IDVisor Pro ID Scanner. User s Guide AGE VERIFICATION MACHINE

Tablet PC User Manual

MICRO-1356 MULTI-PROTOCOL READER

USER GUIDE. 3 Channel DC Current Datalogger Model SD900

RFID Tracking Pad Monitor

TopGuard Online Help PATROL AND PATROL PLUS

PC180 MODBUS COMMUNICATION MANUAL INJECTION MANAGEMENT SYSTEM

Allday PalmReader User Guide

QU I C K-STA RT GUIDE. diagnostics.snapon.com/veruspro

Data Capture for Workforce in Motion. D-Fly User Guide. Baracoda TM February 2010

ProntoPro Intelligent Remote Control. User Guide

ACTpro 1500 Single Door IP Controller

SolarPower Pro. User s Manual. Management Software for Solar Inverter

1. Introduction P Package Contents 1.

Saber Hand Wind Audio Player User Guide

Users Guide. IDBLUE.HF and IDBLUE.UHF. IDBLUE Support

WRTU Client User Manual. Date: 29 May, 2014 Document Revision: 1.05

REPRESENTING INFORMATION:

User Manual Version 1.0

Thermo Scientific VisionMate Wireless Barcode Reader User Manual

Revision: 11/30/ E Main Suite D Pullman, WA (509) Voice and Fax

Table of Contents. Taking a First Look 2 Intelligent Remote Control 2 Before You Start 4

User's Guide. Datalogging Hygro-Thermometer Model SD500

EO-MN910. User Manual. English (USA). 12/2014. Rev.1.0.

Memory Module. Data Logging Guide. For information: Within USA (800) Outside USA (951) Fax (951)

PA2000 SERIES. USER MANUAL Rev. P CELL PHONE ENTRY SYSTEM. Platinum Access Systems Inc.

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology!

Hydrological Services CMC20A OPERATING MANUAL CMC20A. Current Meter Counter

34 E Main Street, Suite 167, Smithtown, NY (888) Fax: 1(888)

Pembina Lake Erie Datalogger Requirements. Preliminary Specification

Division Services. Model: DPAS-300. Division Portable Bulk Load Accumulator Scale INDUSTRIAL PH (901) FAX (901)

Fisher ROC Plus Ethernet Driver Help Kepware, Inc.

Condensed AFM operating instructions:

Setting your PC for operating from a smartphone, iphone, etc. as a controller (Windows 8.1)

ISO11785 Midrange LF Reader. Ordering Code: GOLFPRB550

Help Guide. Getting started. Use this manual if you encounter any problems, or have any questions. What you can do with the Bluetooth function

Using GIGABYTE Notebook for the First Time

DS 1682 Total Elapsed Time Recorder with Alarm

Transcription:

PTLogger User Guide Oregon RFID 4246 SE Ogden St Portland, OR 97206 (503) 788-4380 (866) 484-3174 toll free (866) 611-7087 toll free fax http://www.oregonrfid.com March 31, 2014

Copyright 2009-2013 Oregon RFID, Inc.

Detection history The Oregon RFID reader timestamps tag detections and stores them on a flash memory card. Event messages are also stored which include parameter changes and system exceptions such as low voltage. There is room in the history file for nearly 10 million records along with time-based records every minute for 10 years. To organize these records, the datalogger segments the data into uploads that are shown in a list of upload histories. An upload is added to the history list after new data is retrieved. The upload is numbered to allow retrieving the same records again later on. new detections are added to the end detection record 1 detection record 2 detection record 3 detection record 4 detection record 5 detection record 6 detection record 7 detection record 8 detection record 9 detection record 10 detection record 11 detection record 12 detection record 13 detection record 14 detection record 15 detection record 16 detection record 17 detection record 18 UPLOAD HISTORY Upload 1 Upload 2 Newest records (not yet uploaded 1

Detection record The datalogger displays each detection as long as a tag is in the field. 2014-03-30 18:15:33.22 00:00:00.00 HA 900_228000000076 1 41 2014-03-30 18:15:33.22 00:00:00.10 HA 900_228000000076 2 2014-03-30 18:15:33.22 00:00:00.20 HA 900_228000000076 3 2014-03-30 18:15:33.22 00:00:00.30 HA 900_228000000076 4 2014-03-30 18:15:33.22 00:00:00.40 HA 900_228000000076 5 2014-03-30 18:15:33.22 00:00:00.50 HA 900_228000000076 6 2014-03-30 18:15:33.22 00:00:00.60 HA 900_228000000076 7 2014-03-30 18:15:33.22 00:00:00.70 HA 900_228000000076 8 2014-03-30 18:15:33.22 00:00:00.70 HA 900_228000000076 8 41 DETECT These multiple detections are summarized in the final record marked with the word DETECT at the end. In the above example a tag was detected 8 times with a duration of.70 seconds. Only the final line is written to the log file to record the event. This is the log file record for the detection. D 2014-03-30 18:15:33.22 00:00:00.70 HA 900_228000000076 8 41 The D indicates it is a detection record (rather than an event record). The date and time of the detection is shown along with the total duration. The H indicates it is an HDX tag and an A is displayed when an ICAR registered animal tag is detected. Other possible characters would be R for non-icar tags and W for writeable tags. The tag number in decimal format shows the manufacturer code and the unique tag number. The tag was seen 8 times and there were 41 empty scans before this tag was detected. 2

Graphic Interface PTLogger is a graphic interface program for the Oregon RFID reader that runs on Palm PDAs. Most any modern Palm with a memory card slot will work. PTLogger also supports Bluetooth for a wireless link to the reader. PTLogger is used to configure the reader, monitor its operation and upload datalogger records to the Palm for transfer to a desktop or laptop computer. PTLogger can be downloaded from http://www.oregonrfid.com/software/ Copy the program PTLOGGER.PRC to the Palm, then start it. 3

Status pane The Status pane shows the realtime status of the reader. Single antenna reader Multiple antenna reader The count field shows the number of consecutive readings. The `since last' field shows the time since the last tag was seen. The duration is the amount of time a tag is held in the field. 4

Tapping the name or date field will display a dialog to change it. Tapping on the amperage value on the status screen displays a realtime plot of the average for transmit and receiving. The plot is updated twice a second. The transmit and receive amperages are plotted. The amperage for each antenna is shown for multiplexer readers. The tuning of individual antennas can be performed by finding the maximum value while turning the fine tuning adjustment screw. 5

Voltmeter The reader has an internal voltmeter that is displayed on the Status screen and the value is recorded every minute to the SD card to monitor the voltage over time. The calibration is adjusted by tapping the voltage value on the Setup screen to bring up a dialog to edit it. 6

Setup pane The Setup screens are used to configure the reader. Pulse width and listen duration The 50-50 button sets the charge and listen times to 50 ms for 10 scans per second. 7

Charge pulse width The amperage used by the reader increases significantly when sending the charge pulse. The longer the pulse, the faster the battery will drain. Battery life can be increased by shortening the pulse time or increasing the listen time. Listen time and read rate The read rate (scans per second) is determined by the sum of the charge and listen times. The shortest listen time is 20 ms which is the length of the message from the RFID tag. With a 50 ms charge time, the read rate is 1 / 0.070 or 14 reads per second. Some synchronization modes extend the listen time in order to watch for other readers that are out of synch. With wireless and wired synchronization the minimum listen time is 40 ms or 11 reads per second. The fastet possible read rate using the shortest charge time is 15+20 ms or 26 reads per second. 8

Automatic shutdown voltage The shutdown voltage is the minimum voltage for the reader to run. When the voltage is below this level the reader will shut off to prevent discharging the battery completely. Any automatic shutdown events are logged to the flash memory whenever the reader is turned off. Unfortunately, the datalogger does not log when the reader is switched off. That removes the power to the memory card so it can't be recorded. When the voltage returns to a few volts above the shutdown voltage, the reader will restart and the wakeup event will be written to the log file. The auto-shutdown feature can be disabled by setting the value to zero. 9

Timer operation The reader contains a timer that can be used to turn the reader on and off daily. Comments Comments can be added to the log file on the SD memory card. They are timestamped and will be uploaded along with the other detection records. 10

Multiplexer antenna sequence The sequence editor is used to define custom scan sequences or to select one antenna for tuning. Custom sequences can be added to adjust relative read rates. For example, the sequence ``121314'' will scan antenna 1 twice as often as the others. 11

Maximum scan gap This parameter defines the number of gaps in consecutive scans to ignore. It filters out short breaks in the data stream to reduce the number of records written to the log file. The duration in the scan zone will be measured from the first time a tag is seen until the last, including any gaps less than or equal to this value. If a gap is greater than this parameter, the tag will be considered gone and cause a record to be created in the log file. If the setting is zero, the datalogger will record every scan, including all gaps. 12

Maximum scan gap example The RFID reader repeatedly scans for tags many times per second. The rate is determined by the charge and listen time parameters. Repeated detections are accumulated into records that show the duration and number of consectutive detections. This record shows that the tag was seen for 1.05 seconds for 12 consecutive scans. There was nothing in the field for the previous 59 scans. 09/07/2007 22:22:39.57 00:00:01.05 R 0000_00000000152364970 A3 12 59 Without the scan gap filter, a series of short detections will generate many records. In this example, all are single detections of the same tag with short gaps between them. This can be caused by a tag at the outer edge of the read zone where detections can be missed. 08/08/2008 15:44:39.24 00:00:00.00 R 0000_0000000152364970 A2 1 51 08/08/2008 15:44:40.13 00:00:00.00 R 0000_0000000152364970 A2 1 3 08/08/2008 15:44:41.01 00:00:00.00 R 0000_0000000152364970 A2 1 2 08/08/2008 15:44:41.89 00:00:00.00 R 0000_0000000152364970 A2 1 4 08/08/2008 15:44:42.78 00:00:00.00 R 0000_0000000152364970 A2 1 2 08/08/2008 15:44:43.33 00:00:00.00 R 0000_0000000152364970 A2 1 2 08/08/2008 15:44:44.33 00:00:00.00 R 0000_0000000152364970 A2 1 3 08/08/2008 15:44:45.33 00:00:00.00 R 0000_0000000152364970 A2 1 2 08/08/2008 15:44:46.32 00:00:00.00 R 0000_0000000152364970 A2 1 1 08/08/2008 15:44:47.20 00:00:00.00 R 0000_0000000152364970 A2 1 2 With a scan gap value of 5, the short gaps would be ignored and the ten records above will appear as a single record in the logfile. 08/08/2008 15:44:39.24 00:00:08.35 R 0000_0000000152364970 A2 30 51 13

Utilities The Utilities screens are used for functions that are not changed very often. These include the type of reader, tag display format and synchronization mode selection. Select Single or Multiplexer to match the type of reader. Select the type of tag display you prefer. Decimal format 900_226000054795 Hexadecimal showing the raw tag data 8000E1349EA72A0B BiHex used by the PTAGIS database 384.349EA72A0B 14

Beep mode Beep mode 1 makes a sound for every detection. Beep mode 2 makes a long beep at the start of each new tag detected to indicate that it is a different one. This is useful when moving an antenna across an area to locate tags. Reader synchronization settings There are six synchronization mode settings. Only enable them when necessary. Mode None Wireless Wired Combined M/S Master M/S Slave Description Reader synchronization disabled The reader will adjust its timing to match the transmit pulse heard from another reader. A cable is used to transmit the synch pulse. Both wired and wireless are enabled. The reader generates a pulse over a cable to control others. The reader will transmit when it receives a pulse from a master over the synch cable. 15

Wireless synchronization Wireless mode is useful with a mobile reader when it passes near fixed ones. When multiple readers use this mode however, too many can delay and constantly be out of timing. Extensive instructions for how to setup and configure the various synchronization modes are available from Oregon RFID technical support. Wired synchronization types With Wired or Wireless synchronization, each reader listens for transmit pulses from other readers after it reads a tag ID. If a pulse is detected, the reader delays a short time to try to get in step with the other reader. With Master/Slave, one reader is configured as the master and it sends out a pulse to the slaves. Slaves will not transmit without the signal. When the master is turned off, the system will stop. 16

Reset the reader to factory settings The Reset Datalogger Memory button will erase the database and delete all stored records. The Reset RFID Reader button sets the reader to factory settings: Charge time 50 ms Listen time 50 ms Synch mode off Single antenna reader 17

Archive The datalogger stores all detection and event records in the PDA. The PDA can be used to transfer detection files that are uploaded from multiple readers in the field. Every time an upload file is created in the PDA, the date and time of that batch is written to the upload history list. The starting date and time of a batch of upload records is displayed. It also includes the number of detecion and event records in the batch. Double tapping on a record will display the records in that upload. 18

Detection records An upload file consists of detection and event messages. The date and time of the start of the batch is in the upper corner. Double tapping on one record in the archive will display the record detail. Tap on the Archive field to return to the upload history list. 19

Record detail Two types of records are stored in the reader. Every tag detection generates a timestamped record with (information). Datalogger events are also stored which record when a parameter is changed or something notable has occurred (reader startup, auto-shutdown due to low power). The detection record shows the time of initial detection to 0.01 second, the antenna number, the duration the tag was in the field, the type of tag (R for read, W for writeable), the 64 bit identifier in decimal or hex format, the count of consecutive readings and the number of empty scans before this detection. Tap on a field to return to the record list. Tap on the Archive field to return to the upload history list. 20

Define record format The ASCII text file that is uploaded to the Palm's SD card will contain the tag ID and the date and time of detection. This dialog shows fields that can be included in the exported record. The option Include field names will write one record at the start of the file with the name of each field. These will appear as column headings if the file is imported into a spreadsheet or word processor. The datalogger stores both tag records and event records. The option Include event records causes the event records to be uploaded along with the tag records. The data can be columnated with spaces, tabs or commas. These settings determine the format of the record for uploading. The datalogger always records all values. 21

Upload reader to PDA Detection records are uploaded to the PDA by pressing the Upload Reader to PDA button. A dialog with the suggested file name made from a site code (up to 3 chars), last digit of the year, the month and day. The site code should be unique to each reader in order to keep the data sets separated. The site code can be edited in this dialog. Any changes are stored in the reader and will be used each time the reader is connected. 22

Show PDA Files Pressing the Show PDA Files button shows the uploaded files collected from readers. These files are stored on the SD memory card if the Palm has one. The card can be read by a PC to transfer them. The Meazura PDA is sealed and has no removable memory card. The data can be transferred out the serial port and captured on a PC using Hyperterminal. Select a file and press Download. 23

Capturing reader files sent over the serial port The reader files stored in the PDA can be downloaded over the serial port to another computer. Hyperterminal can be used to capture the PDA output. Select a destination and file name. Press the Download button and when then the capture is complete, stop the capture file. 24

Update datalogger firmware The firmware in the datalogger uses a Firmware Updater program that runs under Windows. You only need to download and install that once. The Firmware Updater accepts update files that are uploaded from the Oregon RFID web site. http://www.oregonrfid.com/software/ Download the latest update (.upd) file Connect the RFID reader to the PC or laptop serial port Start the Firmware Updater program Browse to find the update (.upd) file Start the Updater by pressing the button in the center Turn on the reader (if it's on already, turn it off, then on) The LEDs will flash in a repeating cycle Wait until the updater to complete If the procedure is interrupted, it can be repeated from the start as often as needed. 25

26