Access & Power Integration Solutions

Similar documents
Installation Guide. Versatile Access Power and Integration Enclosures. Trove2M2 - Trove2 enclosure with Altronix/Mercury backplane

Installation Guide Versatile Access Power and Integration Enclosures

Expandable Power Systems

DC Outdoor Power Supply/Chargers

AL168 Series Multi-Output Power Supplies


long range ethernet Extend Ethernet range 5x the distance - without repeaters. Long Range Ethernet Adapters Features:

3-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide

8-Port Ethernet over Fiber PoE Hardened Switches Installation Manual

4-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide

Rack Mount Power Supplies

New IP & Power Solutions. for 2018

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Synergis Cloud Link Hardware Installation Guide 3.0. Click here for the most recent version of this document.

Active UTP Transceiver Hub with Integral Isolated Camera Power

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Transceiver Hub with Integral Camera Power

Active UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

SPECTRUM. Merging infrastructure with emerging technology.

TruPortal Dual Door Interface Module Quick Reference

Universal Desktop and Monitor Stand

Network Power Distribution Module

INSTALLATION INSTRUCTIONS

Passive UTP Transceiver Hub Installation Guide

Installation manual CF8-W-Disp-AL

PoE Managed Midspan Solution for Standard Network Infrastructure

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

User s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1)

Ethernet/Network Communications Module. Installation and Programming Manual. LINQ2 - Two (2) Port Connectivity Module. More than just power.

Temperature. Power requirements. Weight. Dimensions

Instructions to Install Retrofit Kit RVMC 4/5000 Machine (MDB Only)

ProtoBox 1593Q Kit (PCB+Box)

B100 Installation Manual

ProtoBox 1553DBAT Kit (PCB+Box)

Modbus Header Temperature Sensor Kits: Standard Voltage Low Voltage

Enclosures AE1/AE3. Installation Guide

TruPortal Output Expansion Board Quick Reference

Flat Panel Static Wall Mount MSP-SS (GSM-210)

PowerLogic High Density Metering System 1-Meter Enclosure

4100/ VDC Converter Installation Instructions

INSTALLATION INSTRUCTIONS

Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions

Installation Guide GE Healthcare Solar 8000M Keypad Mounting Kit for 15'' and 18'' Flat Panel Displays

USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions

ProtoBox 1593Q Kit (PCB+Box)

Ultima X5000 Rectangular Duct Mount Kit User Instructions

CHASSIS INSTALLATION GUIDE

ProtoBox 1553DBAT Kit (PCB+Box)

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

Model CPS2 - CPS1000. Power Supply / Battery Charger. Operating and Installation Instructions Rev B.02 CPS200/400 ALARMSAF CPS 800/1000 J4 J3

WARRANTY LED ECO PANEL.

Connecting a Cisco Input Module

ebridge200b - Managed Two Port Transceiver Board

Beacon Power Management System Installation Manual

HomeWorks Remote Power Feed-Through Panels

PICO PROTECTOR PG-06 & PK-06 Series

E1135C PDU and Pod Upgrade Procedure

PXC Compact Unitary Equipment Controller (UEC)

MicroTech II TM Remote I/O Panel Installation Manual

PACSystems* RX3i IC695ACC650

Beacon Power Supply Operating and Installation Instruction Manual

Instruction Manual IM E Table of Contents

Digital Keypad Introduction

EWS660AP. Quick Installation Guide

Ing. Enzo Barrella CCTV Dept. Technical Manager Cellulare:

Operation and Maintenance Manual

BACnet Protocol Converter Kit for Use with Bacharach MultiZone Gas Monitors. Installation Manual

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

Kit K Instructions. V8700 to Alpha Conversion Instructions

AC5160 SiPass integrated controller kit

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Procedure to Install an IO Expansion Cage Assembly in a Maxum II Modular Oven Analyzer

EP-ELVCTL Elevator Control (NION-16C48M)

Power-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Enclosure with Mounting Plate and Cooling Fan. Model: NB F. Applications and Features

XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116

2012 IDenticard Systems, Inc.

Safety switches for hinged doors

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

Nokeval. FD100 series. User Manual

Installation Guide. Rev

AP-120 Series AP Mounting Kit

Power Supply (48Vdc, 2.5A)

PCLASS Integrated Paxton Access Power

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Site Preparation CHAPTER

Ohm Metrics. Instruction Manual. Dual Footwear Wrist Strap Tester Model PDT800K

SignBOX II. Retrofit Guide for (X)WS201 and (X)WD201

Installation/Operating Instructions 220V VCB Silhouette/Series E Electric Video Conferencing Background by Draper

Quick Start Guide. Mounting the Essential Plus and Elite

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Installing a Power over Ethernet injector

SITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions

Connecting a Cisco Output Module

PICO PROTECTOR PG-25 & PK-25 Series

BL-FLOWSTN-P FlowStation Module Installation Guide

Safety switches with separate actuator

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

Installing the Tracer MP503 Input/Output Module Ordering number: ,

Transcription:

ccess & Power Integration Solutions Installation Guide for models: T2MK3F4 - (1) eflow6n - Power Supply/Charger - (1) CM4 - Fused ccess Power Controller T2MK3F4Q - (1) eflow6n - Power Supply/Charger - (1) CM4 - Fused ccess Power Controller T2MK3F8 - (1) eflow6n - Power Supply/Charger - (1) CM8 - Fused ccess Power Controller T2MK3F8Q - (1) eflow6n - Power Supply/Charger - (1) CM8 - Fused ccess Power Controller T2MK7F8 - (1) eflow104n - Power Supply/Charger - (1) CM8 - Fused ccess Power Controller T2MK7F8Q - (1) eflow104n - Power Supply/Charger - (1) CM8 - Fused ccess Power Controller T2MK75F16 and TMV2 door backplane - (1) eflow104n and (1) eflow102n - Power Supply/Chargers - (2) CM8 - Fused ccess Power Controller - (1) PD8UL - Power Distribution Module T2MK75F16Q and TMV2 door backplane - (1) eflow104n and (1) eflow102n - Power Supply/Chargers - (2) CM8 - Fused ccess Power Controller - (1) PD8UL - Power Distribution Module T2MK77F16 and TMV2 door backplane - (2) eflow104n - Power Supply/Charger - (2) CM8 - Fused ccess Power Controller T2MK77F16Q and TMV2 door backplane - (2) eflow104n - Power Supply/Charger - (2) CM8 - Fused ccess Power Controller Rev. TMK051217 More than just power. Installing Company: Service Rep. Name: ddress: Phone #:

Overview: Trove Mercury kits are pre-assembled and consist of Trove2M2 enclosure/backplane with factory installed power supply/charger(s) and sub-assemblies. These kits also accommodate various combinations of Mercury boards for up to sixteen (16) doors in a single enclosure. Model Number T2MK3F4 T2MK3F4Q T2MK3F8 T2MK3F8Q T2MK7F8 T2MK7F8Q T2MK75F16 T2MK75F16Q T2MK77F16 T2MK77F16Q Nominal DC Output Voltage Power Supply 1 Power Supply 2 [DC] [ux] [DC] [ux] Output Range (VDC) Output Range (VDC) Output Range (VDC) Output Range (VDC) Configuration Chart: Maximum Supply Current for Main and ux. Outputs on Power Supply board and CM4/CM8 ccess Power Controller s outputs Fail-Safe/Fail-Secure or Dry Form C Outputs 120VC 60Hz Input Current () Current Per CM4/CM8 Output () ---- ---- 24VDC @ 5.8 4 3.5 2.5 ---- ---- 24VDC @ 5.8 4 3.5 2.5 ---- ---- 24VDC @ 5.8 8 3.5 2.5 ---- ---- 24VDC @ 5.8 8 3.5 2.5 ---- ---- 24VDC @ 9.2 8 4.5 2.5 ---- ---- 24VDC @ 9.2 8 4.5 2.5 9.7-13.2 9.7-13.2 10.03-13.2 10.03-13.2 12VDC @ 9.3 24VDC @ 9.2 12VDC @ 9.3 24VDC @ 9.2 16 8 2.5 16 8 2.5 24VDC @ 9.2 16 9 2.5 24VDC @ 9.2 16 9 2.5 Power Supply oard Input Fuse Rating 5/ 5/ 5/ 5/ 6. 6. 6. 5/ 6. 5/ 6. 6. Power Supply oard attery Fuse Rating 15/ 15/ 15/ 15/ 15/ 15/ CM4/CM8 oard Input Fuse Rating CM4/CM8 oard Output Fuse Rating PDS8 oard Input Fuse Rating PDS8 oard Output Fuse Rating PD8UL oard Output Fuse Rating ---- ---- ---- ---- ---- ---- ---- ---- 3.5/ ---- ---- 3.5/ ---- ---- Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFP 70/NSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only. 1. Remove backplane(s) from enclosure. Do not discard hardware. 2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure s upper keyholes over the three upper screws, level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure s upper keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws. 3. Mount included UL Listed tamper switch (Honeywell Model 112 or equivalent) in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2 from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the ccess Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure. 4. Refer to the eflow Power Supply/Charger Installation Guide (eflow6n, eflow102n, eflow104n) and Sub-ssembly Installation Guide for the following models: CM4C, CM8C, LINQ2, PDS8C, VR6 for further installation instructions. 5. Fasten snap on standoffs onto metal pems configuration of backplane depending on the Mercury access controller (Fig. 2-5, pg. 3-6). 6. Position Mercury access controller module over corresponding standoffs and depress onto snap on standoffs (Fig. 2-5, pg. 3-6). 7. Mount backplane to enclosure with hardware. Honeywell model # 112 Tamper Switch or equivalent (provided) Enclosure to ccess Control Panel or U.L. Listed Reporting Device Fig. 1 Edge of Enclosure - 2 - T2MK Kits

T2MK3F4: One (1) eflow6n - 24VDC @ 6 Power Supply/Charger, one (1) CM4-4 fused output ccess Power Controller, one (1) VR6-24VDC input to 12VDC output Voltage Regulator, and one (1) PDS8-8 fused output Dual Input Power Distribution Module. T2MK3F4Q: One (1) eflow6n - 24VDC @ 6 Power Supply/Charger, one (1) LINQ2 Network Communication Module, one (1) CM4-4 fused output ccess Power Controller, one (1) VR6-24VDC input to 12VDC output Voltage Regulator, and one (1) PDS8-8 fused output Dual Input Power Distribution Module. T2MK3F8: One (1) eflow6n - 24VDC @ 6 Power Supply/Charger, one (1) CM8-8 fused output ccess Power Controller, one (1) VR6-24VDC input to 12VDC output Voltage Regulator, and one (1) PDS8-8 fused output Dual Input Power Distribution Module. T2MK3F8Q: One (1) eflow6n - 24VDC @ 6 Power Supply/Charger, one (1) LINQ2 Network Communication Module, one (1) CM8-8 fused output ccess Power Controller, one (1) VR6-24VDC input to 12VDC output Voltage Regulator, and one (1) PDS8-8 fused output Dual Input Power Distribution Module. Fig. 2 LINQ2 (T2MK3F4Q, T2MK3F8Q) eflow6n CM4 (T2MK3F4) or CM8(T2MK3F8) PDS8 & VR6 T2MK Kits - 3 -

T2MK7F8: One (1) eflow104n - 24VDC @ 10 Power Supply/Charger, one (1) CM8-8 fused output ccess Power Controller, one (1) VR6-24VDC input to 12VDC output Voltage Regulator, and one (1) PDS8-8 fused output Dual Input Power Distribution Module. T2MK7F8Q: One (1) eflow104n - 24VDC @ 10 Power Supply/Charger, one (1) LINQ2 Network Communication Module, one (1) CM8-8 fused output ccess Power Controller, one (1)VR6-24VDC input to 12VDC output Voltage Regulator, and one (1) PDS8 - eight 8 fused output Dual Input Power Distribution Module. Fig. 3 LINQ2 (T2MK7F8Q) eflow104n CM8 PDS8 & VR6-4 - T2MK Kits

T2MK75F16: One (1) eflow104n - 24VDC @ 10 Power Supply/Charger and one (1) eflow102n - 12VDC @ 10 Power Supply/Charger, two (2) CM8-8 fused output ccess Power Controller, and one (1) PD8UL - 8 fused output Power Distribution Module. T2MK75F16Q: One (1) eflow104n - 24VDC @ 10 Power Supply/Charger and one (1) eflow102n - 12VDC @ 10 Power Supply/Charger, one (1) LINQ2 Network Communication Module, two (2) CM8-8 fused output ccess Power Controller, and one (1) PD8UL - 8 fused output Power Distribution Module.. Fig. 4 LINQ2 (T2MK75F16Q) eflow104n PD8UL eflow102n CM8 CM8 T2MK Kits - 5 -

T2MK77F16: Two (2) eflow104n - 24VDC @ 6 Power Supply/Charger, two (2) CM8-8 fused output ccess Power Controller, one (1) VR6-24VDC input to 12VDC output Voltage Regulator and one (1) PDS8-8 fused output Dual Input Power Distribution Module. T2MK77F16Q: Two (2) eflow104n - 24VDC @ 6 Power Supply/Charger, one (1) LINQ2 Network Communication Module, two (2) CM8-8 fused output ccess Power Controller, one (1) VR6-24VDC input to 12VDC output Voltage Regulator and one (1) PDS8-8 fused output Dual Input Power Distribution Module. Fig. 5 LINQ2 (T2MK77F16Q) eflow104n PDS8 & VR6 eflow104n CM8 CM8-6 - T2MK Kits

TMV2 (T2MK75F16, T2MK75F16Q, T2MK77F16, and T2MK77F16Q): TMV2 accommodates a variety of Mercury boards with or without sub-assemblies for access systems. Configuration of Mercury and/or oards Mercury ccess Controllers: 1. Fasten snap on standoffs onto metal pems configuration () () of backplane depending on the access controller (Fig. 5, pg. 6). 2. Position access controller module over corresponding standoffs and depress onto snap on standoffs (Fig. 5a, pg. 6). 3. Mount backplane to enclosure with hardware. Sub-ssemblies and/or dapters: 1. Fasten nylon / snap on standoffs to pems which match the hole pattern for Sub-ssemblies (Fig. 5, 5a, pg. 6). 2. Mount boards to standoffs utilizing pan head screws provided with the product or by depressing board onto snap on standoff (Fig. 5, pg. 6). Note: For G1 please use standoffs supplied with the adapter. ccess Controller Position Chart for the Following Models: Mercury ccess Controller EP1502, MR52, MR16IN, MR16OUT EP2500, MUX8 Sub-ssembly or dapter CM4(C), MOM5, PD4UL(C), PD8UL(C), PDS8(C), VR6, G1 (Genetec Synergis Cloud Link adapter plate) Pem Mounting Pem Mounting C Fig. 5 Nylon Standoff Fig. 5a C Pem Snap on Standoff ackplane Sub-ssembly C C T2MK Kits - 7 -

2.00 Enclosure Dimensions (H x W x D approximate): 27.25 x 21.5 x 6.5 (692.15mm x 552.5mm x 165.1mm) 5.25 (133.35mm) 3.50 (88.9mm) 21.50 (546.1mm) 3.50 (88.9mm) 5.25 (133.35mm) 1.25 (31.75mm) 0.5625 (14.29mm) 2.415 (61.34mm) 1.77 (44.96mm) 0.685 (17.399mm) Knockouts 1.125 (28.32mm) 0.885 (22.479mm) 6.25 (158.75mm) 6.25 (158.75mm) 1.25 (31.75mm) 0.85 (21.59mm) 1.5 (38.1mm) 19.80 (502.92mm) 2.00 6.75 (171.45mm) G 27.00 (685.8mm) 8.25 (209.54mm) 8.00 (203.2mm) 0.85 (21.59mm) 2.00 1.00 (25.4mm) 1.25 (31.75mm) 1.25 (31.75mm) 2.00 5.25 (133.35mm) 7.00 (177.79mm) 5.25 (133.35mm) 2.00 is not responsible for any typographical errors. 140 58th Street, rooklyn, New York 11220 US phone: 718-567-8181 fax: 718-567-9056 web site: www.altronix.com e-mail: info@altronix.com Lifetime Warranty Made in U.S.. IITrove2M2 Kit Series 12R MEMER - 8 - T2MK Kits