Sir Walter Scott may not have been thinking of building automation systems. How BACnet. Is Connecting At ASHRAE s Headquarters

Similar documents
i-vu Building Automation System VVT Zoning System Total Control and Comfort for Your Building

Key Features and Benefits

Energy Engineering: Tools and Trends

ECLYPSE Series Connected IP and Wi-Fi Product Series and Accessories

TRACE 700 Learning Series Module 2: Navigation

Developing an Action Plan: Building Energy Metering and Beyond

30 top tips to tackle HVAC challenges No.15 - BACnet

Operator Workstations. In the BBC Radio Series The Hitchhiker s Guide to the Galaxy a civilization. BACnet. BACnet Today & the Smart Grid

Trailblazer AGZ-E air-cooled scroll chillers

We have you walking on air

Product Catalog. senseware.co Tysons Boulevard Floor 5 Tysons VA, 22102

Commercial Controls. Advanced control for saving time and money

PoolPak MPK with CommandPak Control System CPCS BACnet /IP User s Guide DOCUMENT #: SVW07-MPKBACNIP

The Bard BrightStat Room Controllers

The Simply Smart Way to Optimize Building Control and Performance

Belimo Energy Valve Solving Low Delta T Leveraging IoT.

Control systems. Efficient room control

BCPro System Product Bulletin

Driving Proactive Facility Operations with Automated HVAC Diagnostics

Trane Controls. Smart Solutions for Smart Buildings

BAS Chillers 8/15/2016. Achieving Energy Savings with BAS and Data Analytics Guanjing Lin Lawrence Berkeley National Laboratory August 10, 2016

Airside Economizer Comparing Different Control Strategies and Common Misconceptions

Simplifying Device and System Integration Specifications for Building Automation Systems

Building Management Solutions. for Data Centers and Mission Critical Facilities

HOURLY ANALYSIS PROGRAM 5.10

BACnet MS/TP Interface User s Guide

Room Automation Solutions. Freeing up space in building automation.

Airside Economizer Comparing Different Control Strategies and Common Misconceptions

Leveraging Building Automation Systems to support ongoing commissioning

DUKE UNIVERSITY DESIGN & CONSTRUCTION STANDARDS

SE7600E Series Application Guide

building performance Reliable Controls Authorized Dealer, LCS Control Systems, completed this project for the Coral Leisure Centre

WHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

What a BACnet system looks like and how it can be used generally depends. By Roland Laird

Discussion Topics. Integrated System Definition. Two Primary Characteristics. Understanding and Specifying Open Protocol Syracuse, NY April 2009

Introduction to the N30 Supervisory Controller

Cabling Infrastructure for Green Buildings. Dr. Paulo Marin, EE, MSc. Paulo Marin Consultoria Phone: (201)

Title of Presentation Goes Here. Presenter Name Title, Company

Communicating Wall Control Owner s Manual TSTAT0101SC

BACnet Product Overview

Engineered Energy Solutions An Overview. Controls, Automation and Energy Conservation

Samuel Tepp Engineering Seminar Topics

Smart heating system. with wireless thermostats & smartphone control for every room. Get the most out of any water based underfloor heating

Modernizing Control Systems for Campuses

Product Overview. KMC Controls Building Geniuses since Learn more about our entire product line at: KMCControls.com

SMART VENTILATION MANAGEMENT: CHANGING THE WAY WE THINK ABOUT VENTILATION

Andover ContinuumTM. Family of Controllers. BACnetTM

Communicating Submeter Data Via BACnet

Product Data. SYSTXCCUIZ01-- B Infinityt Zone Control. INFINITY t ZONE CONTROL

Product Data. SYSTXBBUIZ01 -B EVOLUTIONt ZONE CONTROL. EVOLUTION t ZONE CONTROL

CGAM air-cooled scroll chiller. Highly efficient, yet extremely quiet

White Paper Technology Infrastructure Upgrade Boosts Performance of Older Buildings In today s environment, older buildings need to support ongoing fu

SOFTWARE TOOLS FROM BUILDINGS ENERGY SIMULATION

KMC Product Overview

Fan-Powered VAV Terminal Units

VZ7000 Series. BACnet Commercial Zoning System

RCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs

Daikin HVAC Controls Guide Specification

Optimizing Laboratory Controls through Fault Detection and Diagnostics Software. Laura Dyas, PE, LEED AP O+M, CEM Bryce Buchanan, PE, CCP, CEM

Data Center Infrastructure Management (D.C.I.M.)

ASHRAE elearning Course Catalog

Automation Monitoring Control. EDN 2010 Hot 100

SEZ7000 Series. Wireless Commercial Zoning System

M2M Solutions that Use IT for Energy Efficiency and Comfort in Offices

The BACnet history He has a real problem...

Validation and Uncertainty Characterization for Energy Simulation

Google s Green Data Centers: Network POP Case Study

Running Your Data Center Under Ideal Temperature Conditions

ASHNuN. Fundamentals of HVAC Control Systems. Robert McDowell and Ross Montgomery are the authors of the

Connect hydronics and Building Automation and save time in every phase

clarity 3 Programmable Controller

RCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs

Product Catalog. Tracer Controls Tracer ZN517 Unitary Control BAS-PRC012-EN. August 2010

How Big Data Analytics Helps Hotels Improve Maintenance and Comfort, and Save Energy

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN

Building Management Systems (BMS) Back to Basics. Presented By: Andrew Smith Leader Building Technologies A.G. Coombs Advisory

Campus Continuous Improvement with Controls. Bill Broadhurst, PE, CEM, LEED AP Campus Energy Manager

Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication

August 2017 Welcome Design Topic Product Focus

HOURLY ANALYSIS PROGRAM v5.00 and v5.01

Daikin HVAC Controls Guide Specification

Committed to Energy Efficiency

Product Data. SYSTXCCITW01---A, SYSTXCCITC01---A & SYSTXCCITN01---A Infinityr Touch Control INDUSTRY LEADING FEATURES/BENEFITS INFINITYR TOUCH CONTROL

RCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs

Installation and Operation Instructions

Building Energy Management Training Systems

Product Catalog. Tracer SC System Controller For Tracer Building Automated Systems BAS-PRC031-EN. January 2011

Wall-Mounted Air Conditioners with PLC Technology. Let Logic Control The Flow

Building Automation Building Trends and Industry Perspective on Future Landscape

Government Connections GEMnet Project Links Buildings in 3 States

System Controls Suggested Specification

Climatix Sales Presentation. Kurt Steiner / xxx-x-xxx

Building Re-Tuning (BRT) Lesson 4: SOI Air-Handling Unit Part II

One system for all requirements of an intelligent building siemens.com/desigo

Installation Manual. DZK BACnet

New Wisconsin Energy Code: What it Means for Me?

Fan-Powered VAV Terminal Units

Working with BACnet Group Objects

The challenge is that BAS are often very complex with 1000s of data points to review. EMS Optimization Software

Transcription:

This article was published in ASHRAE Journal, November 2009. Copyright 2009 American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without permission of ASHRAE. For more information about ASHRAE Journal, visit www.ashrae.org. An Un ^ How BACnet Is Connecting At ASHRAE s Headquarters By Steve Tom, Ph.D., P.E., Member ASHRAE Tangled Web Oh what a tangled web we weave, When first we practice to deceive! Sir Walter Scott may not have been thinking of building automation systems when he penned those lines, but until BACnet came along anyone who tried to build a control system using products from multiple vendors might have felt the vendors were trying to deceive. At the very least, they certainly weren t trying to make things easy. Proprietary protocols, multiple network topographies, custom user software, and incompatible wiring turned many control rooms into a tangled mess. BACnet became the great untangler. Add another level of The ASHRAE Headquarters building was originally constructed in 1965 to provide offices for an insurance company. ASHRAE purchased the building in 1981, performed extensive renovations, and made other modifications to the building throughout the 1990s. 1 As with many buildings that have lived through multiple changes in use and configuration, energy efficiency and indoor environmental conditions fell somewhat short of ideal. The ASHRAE Board of Directors decided in 2005 to initiate a major building renovation with sustainability as a central theme. They set a goal of achieving LEED-EB and LEED-NC Gold ratings from the U.S. Green Buildings Council. They also decided to create a Living Lab and make building performance data available to researchers around the world via the Internet. 2 Since no one company has a monopoly on good ideas, the decision to openness by putting the control system on the Web, and you have the ASHRAE Headquarters Renovation project. About the Author Steve Tom, Ph.D., P.E., is director of technical information at Automated Logic in Kennesaw, Ga. B 1 4 B A C n e t To d a y A S u p p l e m e n t t o A S H R A E J o u r n a l November 2009

Various Weather Forecast Servers Internet Automated Logic Web Server Web Browser Web Browser HTML HTML BACnet Over IP (On Existing Building LAN) Environmental Index and Miscellaneous Fan Coil Units Lighting Control Router Router Gateway Air Quality Monitoring Dedicated Outdoor Air Supply BACnet Over ARCNET BACnet MS/TP MODBUS Water Source Heat Pump Power Monitoring Flow Monitoring Ventilation Control Weather Station Figure 1: Controllers monitor overall building conditions and miscellaneous monitoring systems. make this a showcase for innovative building technologies meant there would be multiple vendors equipment used in this project. The operation of this equipment had to be closely integrated to maximize the overall building performance, which made BACnet the logical choice for the building automation system. BACnet was designed from the ground up to provide a common protocol for building automation, allowing manufacturers of HVAC, lighting, and other building systems to communicate freely. It also provides a widely accepted interface for equipment using other protocols, such as MODBUS, to interface with the main building automation system. In this project, BACnet integrates information from 23 types of major equipment made by seven manufacturers into a single user interface. Much of this equipment is native BACnet, but MODBUS and HTML protocols are also integrated into the system. The user interface presents roughly 1800 I/O points and key software values on the graphics, with countless additional data values available through trends, schedules, configuration properties, and other detail screens. The BACnet network consists of a BACnet over IP backbone that runs over the existing building LAN. Five BACnet routers link this backbone to two BACnet over ARCNET controller networks and three BACnet MS/TP controller networks. One hundred and twenty control devices are connected to these networks. Device IDs are generally assigned by the vendor that supplied the device, using the convention of having the vendor s BACnet number serve as the first two numbers of the device ID. Overall coordination of the device IDs and integration of the BACnet system was performed by the vendor who supplied the main building automation system. A conceptual network diagram of this system is shown in Figure 1. Figure 1 shows that controllers that monitor the overall building conditions and miscellaneous monitoring systems (environmental Index, 3 refrigerant leak monitoring, photovoltaic power monitoring, etc.) are connected directly to the BACnet/ IP backbone. This network also has an indoor air quality monitoring system. The air monitoring system automatically retrieves air samples from throughout the building, and tests the samples for CO 2, particulates, and humidity using laboratory quality sensors. Variable refrigerant flow (VRF) fan coil units provide primary heating and cooling on the first floor of the building. These units can be accessed via a manufacturer s control panel connected to the BACnet/IP backbone. Ventilation is provided by a dedicated outdoor air supply (DOAS) unit from a different vendor that supplies zone VAV boxes controlled by a third vendor. BACnet integration of schedules, overrides, sensor readings, and other key data is essential to the operation of these units. Some custom integration logic was required for the fan coil units because the operating modes for these units did not directly correlate to the heating and cooling setpoints used by other equipment and because these units operated on Celsius while the rest of the building systems operated on Fahrenheit. A typical fan coil graphic is shown in Figure 2. The data on this graphic comes from three vendors, but BACnet allows it to be seamlessly integrated into a single user interface. A field-installed set of dampers and airflow stations controlled by the primary BAS manufacturer controls the flow through the unit to maintain the required ventilation and building static N o v e m b e r 2 0 0 9 B A C n e t To d a y A S u p p l e m e n t t o A S H R A E J o u r n a l B 1 5

pressure, while the unit is controlled by an OEM BACnet controller that sits on the IP backbone. All the zones within the building communicate their needs for heating, cooling, ventilation, and dehumidification to the controls for this unit, which then adjusts its operation to meet the aggregate needs of the building. More than 200 BACnet communication links are used to optimize the control of this unit. The primary graphic for this unit is shown in Figure 3. A separate graphic was used to illustrate the control of the dampers and airflow stations. Lighting control is provided by BACnetcontrolled circuit breakers connected to the IP network. Zones near outside walls contain photocells that automatically scale back on the amount of energy used for artificial lighting when natural lighting is available. Interestingly, these sensors are connected to a controller made by a different vendor than the lighting panel but are integrated into the lighting control scheme using BACnet. Ventilation for the VRF zones on the first floor and heating, cooling, and ventilation for the water source heat pumps (WSHP) on the second floor are controlled by controllers on a BACnet over ARCNET field bus. This is connected to the main IP backbone by a BACnet router. Since the networks on both sides of this router are BACnet, complex data such as Figure 2: BACnet allows data from three vendors to be integrated in one place. alarms, schedules and trends pass freely through the router. The router simply transfers the BACnet messages from one medium to another, similar to the way telecommunica- Figure 3: More than 200 BACnet communication links optimize control of this dedicated outdoor air system. B 1 6 B A C n e t To d a y A S u p p l e m e n t t o A S H R A E J o u r n a l November 2009

tions routers transfer audio and data signals between fiber optics and copper wire. A similar router connects the main IP backbone to a BACnet MS/TP network used to provide independent monitoring of selected VAV boxes. A typical graphic for one of the WSHP units is shown in Figure 4. As with the other graphics, information on this graphic comes from multiple manufacturers systems. Power monitoring and data from an outdoor weather station are provided through a MODBUS interface. This requires a protocol translator or gateway between the two networks. As is typical of gateways, this transfers individual data values but not complex data structures like schedules or trends. Neither of the MODBUS systems requires schedules, and trending of the data from the MODBUS devices is provided by a BACnet controller on the BACnet side of the gateway. The power monitoring includes total building consumption and submetering of the major systems, lighting loads, and plug loads on each floor. (As a side note, the MODBUS meters and BACnet lighting controls are from the same manufacturer. It is not unusual for manufacturers to offer this type of equipment with two or three protocol options, to make integration easier.) At the top level, a Web server collects information from all the vendors equipment and generates Web pages that provide the user interface to the system. Depending on the privileges assigned to them, users can view the system, run reports, make minor adjustments to setpoints and other operating parameters, or make major changes to the control logic through a standard Web browser. These browsers can be connected to the local building network or anywhere with Internet access. As shown in Figure 1, this Internet link also allows weather forecasts to be incorporated into the BAS Web pages. If the weather data had been needed by control applications, a BACnet Web services link could have been established, but since the information is only being presented as information on a graphic a simple html link between Web pages is used. A Web services link will be used in the future to extract data from the system and make it available to researchers accessing the Living Lab data. Figure 1 shows how everything should connect in theory. How does it work in the real world? Very well, according to Charles Miltiades, an engineer with Automated Logic of Georgia and the primary controls designer on the project. We provided the equipment suppliers with the device instance numbers and IP addresses we wanted them to use, and then we used BACnet discovery to map their points. He noted that this was easier and less error prone than trying to type point addresses into all the integration mappings, like they had to do with the MODBUS interfaces. The most difficult part of the integration was getting the fan coil units and the ventilation units to work together to achieve the desired zone temperature, as the operating sequence for the fan coil units did not use heating and cooling setpoints in the same way the ventilating units did. This was a controls challenge, but not a protocol issue. Once Miltiades figured out how to get the dif- Advertisement formerly in this space. N o v e m b e r 2 0 0 9 B A C n e t To d a y A S u p p l e m e n t t o A S H R A E J o u r n a l B 1 7

Figure 4: Typical water source heat pump graphic, displaying data from multiple manufacturers equipment. ferent equipment sequences to work together, BACnet made it easy to link them. Miltiades also noted that this project, by its nature, enjoyed a high level of support and cooperation by all the vendors. He has worked on other projects where the local representatives were not easily found or did not know what points were available through their equipment interfaces. BACnet discovery is even more valuable on those projects he observed. From the end-user perspective, BACnet provides a seamless integration. It appears to the user to be one large system, said Michael Vaughn, ASHRAE s manager of research and technical services. He also noted that it allows me to easily recognize subsystems and navigate, for example, between the building s weather station, sub-metered power panels, and zone set-points with just a click or two of the mouse. The ability to trend and view points on a variety of systems with just a few clicks is another big improvement for us. Vaughn estimates the building s energy use is about 30% below the baseline consumption in 2007, but there is still room for improvement. We are still commissioning some systems for the cooling season and optimizing others, he said. The BAS has been very useful in this effort by helping to identify areas that require additional attention or could be improved. This is helping them to exceed their initial goals for the building. They believe they have more than enough points to qualify for a Platinum rating under LEED-NC, but USGBC is still reviewing the construction phase credits. Vaughn described some additional goals, We also hope to obtain a new construction rating under the Green Building Initiative s Green Globe rating system. Once the building is fully commissioned and after we have a full year s worth of operating data, we plan to obtain ratings under LEED EB, ENERGY STAR, and Green Globes to name a few. Perhaps most importantly, he noted that the system provides a consistent space environment year-round, which gives people a comfortable and healthy place to work. References 1. ASHRAE. 2008. Succeeding in Sustainability, Headquarters renovation dedication booklet. 2. Jarnagin, R.E., M.R. Brambley. 2008. ASHRAE s Living Lab. ASHRAE Journal 50(10):12 20. 3. Tom, S. 2008. Managing Energy and Comfort. ASHRAE Journal 50(10):18 26. B 1 8 B A C n e t To d a y A S u p p l e m e n t t o A S H R A E J o u r n a l November 2009