IBM United States Announcement 108-068, dated January 29, 2008 IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems Key prerequisites...2 Description...2 Publications... 3 Services...3 Technical information...4 Cable orders... 9 Terms and conditions... 13 Prices...15 Order now...16 At a glance The IBM 9910 Uninterruptible Power Systems offer you: Models that are tested and approved by IBM An extended Eaton-Powerware Five-Year Gold Plan warranty supported by IBM A premium service package (including battery) Enhanced conditioning of utility power and battery backup For ordering, contact: Your IBM representative, an IBM Business Partner, or the Americas Call Centers at 800-IBM-CALL Reference: YE001 Overview All IBM 9910 Uninterruptible Power Systems have passed IBM's testing procedures and are intended to provide a convenient, single source for protection of IBM servers. These new 9910 products are compatible with the power requirements of: System i5 and p5 servers iseries, pseries, and OpenPower servers AS/400 and RS/6000 servers IBM TotalStorage solutions All 9910 Uninterruptible Power Systems include a premium Eaton-Powerware Five-Year Gold Plan warranty package that is designed to enhance the potential for a return on investment as compared to other power supplies available on the market today. In addition, the warranty: Extends coverage of the device (refer to the specific product warranty period) Provides remote problem determination and next-day exchange (if available) by the device manufacturer (when necessary) Offers a single point of contact through the IBM Call Center With today's announcement, IBM offers the following Eaton Powerware devices: IBM 9910 Model E30 (Powerware 9125) is a 3 kva, 208 to 240 V ac, rack-mounted or tower unit that helps protect your equipment up to IBM United States Announcement 108-068 IBM is a registered trademark of International Business Machines Corporation 1
2100 watts. IBM 9910 Model E33 (Powerware 5125) is a 3 kva, single-phase, 2U low profile, high-power, rack-mounted unit that helps protect your equipment up to 2,700 watts. IBM 9910 Model E64 (Powerware 9125) is a 6 kva, 208 to 240 V ac, rack-mounted or tower unit that helps protect your equipment up to 4200 watts. IBM 9910 Model E65 (Powerware 5125) is a 5 kva, single-phase, 3U low-profile, high-power, rack-mounted unit that helps protect your equipment up to 4,500 watts. IBM 9910 Model E82 (Powerware 9140) is a 10 kva, online double-conversion single-phase unit that helps protect your equipment up to 8000 watts in a 6U form factor. For a complete description of each device, refer to the Description section of this announcement. Key prerequisites The key prerequisites consist of the operating system and the selected applications that are required for your business. Planned availability dates March 3, 2008: 9910 Models E30, E33, E64, and E65 April 15, 2008: 9910 Model E82 Description Powerware Uninterruptible Power Systems The IBM 9910-E30 (Powerware 9125) 3000 VA, 208 to 240 V ac, single-phase Uninterruptible Power System helps protect equipment up to 2100 watts. This true online, double-conversion device features Advanced Battery Management (ABM) technology which can double battery service life, load segments for scheduled shutdowns, extended runtimes, and a versatile design that allows the power system to be mounted in a rack or as a tower. The ability to add up to four optional extended battery modules extends battery runtimes. The ConnectUPS Web/SNMP/xHub card adapter or X-Slot Relay/Serial card expands control and monitoring of the power system and network devices. The IBM 9910 Model E33 (Powerware 5125) is a universal 2700 watt, high-voltage device that has been customized for IBM environments, delivering advanced power protection in a sleek, compact design. It can help you meet your ever-expanding configuration needs. The ability to add up to four extended battery modules (feature number 6643) makes the E33 the ultimate power protection choice for almost any business configuration. The ConnectUPS Web/SNMP/xHub card adapter or X-Slot Relay/Serial card expands control and monitoring of the power system and network devices. The IBM 9910-E64 (Powerware 9125) 6000 VA, 208 to 240 V ac, single-phase Uninterruptible Power System protects equipment up to 4200 watts. This true online, double-conversion UPS features ABM technology which can double battery service life, load segments for scheduled shutdowns, extended runtimes, and a versatile design that allows the UPS to be mounted in a rack or as a tower. The ability to add up to four extended battery modules (#6645) makes the E64 a good power protection choice for almost any business configuration in a tower or rack environment. The ConnectUPS Web/SNMP/xHub card adapter or X-Slot Relay/Serial card expands control and monitoring of the power system and network devices. The IBM 9910-E65 (Powerware 5125) 5000 VA, 208 to 240 V ac, single-phase Uninterruptible Power System is a low-profile, rack-mounted unit that is designed to protect equipment up to 4500 watts. This model features ABM technology which is designed to double battery service life, load segments for scheduled shutdowns, and maximized runtimes. The E65 high-capacity, low-profile design allows the device to be mounted in a rack in just 3U of space. The ability to add up to four optional battery modules helps extend battery runtimes. The ConnectUPS Web/SNMP/xHub card adapter or X-Slot Relay/Serial card expands control and monitoring of the power system and network devices. The IBM 9910 Model E82 (Powerware 9140) 10 kva, single-phase Uninterruptible Power System protects equipment up to 8000 watts. This online double-conversion single-phase unit IBM United States Announcement 108-068 IBM is a registered trademark of International Business Machines Corporation 2
delivers 10 kva of power in a 6U form factor. The E82 unit uses Hubbell style 60 amp input and output connectors common with the PDU power cord feature 6492. The unit also provides four IEC 320 C19 outputs and supports up to four extended battery units (#6646) for extended run time. It also offer multiple communication protocols for serial connection as well as AS/400 relay communication. The 9910 Models E30, E33, and E65 include power cords to accommodate a variety of configurations. In addition, 9910 Models E30, E33, E64, and E65 include rails and hardware for easy installation into IBM racks. The 9910 Model E82 includes rails and hardware for easy installation into IBM racks. Powerware offers the X-Slot Relay/Serial Kit (#2939) with an AS/400 interface and serial cables to provide power save capabilities for i5/iseries/as/400 rack clients with an i5 and a Microsoft Windows, AIX, Linux, or other operating system server. Accessibility by people with disabilities For hardware offerings, the following features support use by people with disabilities: Controls and latches are operable with one hand and limited dexterity. Keys are discernible by touch without activating them. Ports and connectors support connection of industry-standard devices. Business Partner information If you are a Direct Reseller - System Reseller acquiring products from IBM, you may link directly to Business Partner information for this announcement. A PartnerWorld ID and password are required (use IBM ID). BP Attachment for Announcement Letter 108-068 https://www.ibm.com/partnerworld/mem/sla.jsp?num=108-068 Trademarks System i5 and iseries are trademarks of International Business Machines Corporation in the United States or other countries or both. OpenPower, pseries, AS/400, RS/6000, TotalStorage, and AIX are registered trademarks of International Business Machines Corporation in the United States or other countries or both. Microsoft and Windows are registered trademarks of Microsoft Corporation. Linux is a trademark of Linus Torvalds in the United States, other countries or both. Other company, product, and service names may be trademarks or service marks of others. Publications Product-specific publications are shipped with the products. Additional copies are available from the associated UPS supplier. Services Global Technology Services IBM services include business consulting, outsourcing, hosting services, applications, and other technology management. These services help you learn about, plan, install, manage, or optimize your IT infrastructure to be an On Demand Business. They can help you integrate your high-speed networks, storage systems, application servers, wireless protocols, and an array of platforms, middleware, and communications software for IBM and many non-ibm offerings. IBM is your one-stop shop for IT support needs. IBM United States Announcement 108-068 IBM is a registered trademark of International Business Machines Corporation 3
For details on available services, contact your IBM representative or visit http://www.ibm.com/services/ For details on available IBM Business Continuity and Recovery Services, contact your IBM representative or visit http://www.ibm.com/services/continuity For details on education offerings related to specific products, visit http://www.ibm.com/services/learning/index.html Select your country, and then select the product as the category. Technical information Specified operating environment Physical specifications: Physical specifications are subject to change. More detailed specifications can be obtained from your IBM representative or at the following Web site http://www.powerware.com/ibm Model E30 (3000 VA, 2100 W) Width: 43.18 cm (17.0 in) Depth: 60.71 cm (23.9 in) Height: 8.89 cm (3.5 in), 2 EIA units Weight: 36.97 kg (81.5 lb) Feature 6644 (Extended Battery Module for E30) Width: 43.18 cm (17.0 in) Depth: 62.87 cm (24.75 in) Height: 8.89 cm (3.5 in), 2 EIA units Weight: 42.18 kg (93 lb) Model E33 (3000 VA, 2700 W) Width: 44 cm (17.5 in) Depth: 61 cm (24.0 in) Height: 9 cm (3.5 in) Weight: 37 kg (82.0 lb) Feature 6643 (Extended Battery Module for E33) Width: 44 cm (17.5 in) Depth: 61 cm (24.0 in) Height: 9 cm (3.5 in), 2 EIA units Weight: 46 kg (100 lb) Note: Each of the two battery packs comprising feature number 6643 weighs 21 kg/45 lb. IBM United States Announcement 108-068 IBM is a registered trademark of International Business Machines Corporation 4
Model E64 (6000 VA, 4200 W) Width: 43.18 cm (17.0 in) Depth: 63.35 cm (24.94 in) Height: 21.92 cm (8.63 in), 5 EIA units Weight: 93.44 kg (206 lb) for Chassis, 7 kg (37 lb) for each internal battery tray (2 trays per each E64) Feature 6645 (Extended Battery Module for E64 and E65) Width: 43.18 cm (17.0 in) Depth: 62.87 cm (24.75 in) Height: 13.35 cm (5.25 in), 3 EIA units Weight: 76.66 kg (169 lb) Model E65 (5000 VA, 4500 W) Width: 44.5 cm (17.5 in) Depth: 66.1 cm (26.0 in) Height: 13.3 cm (5.25 in), 3 EIA units Weight: 73 kg (161 lb) for Chassis, 7 kg (37 lb) for each internal battery tray (2 trays per each E65) Feature 6646 (Extended Battery Module for E82 and E83) Width: 43.18 cm (17.0 in) Depth: 62.87 cm (24.75 in) Height: 13.35 cm (5.25 in), 3 EIA units Weight: 76.66 kg (169 lb) Model E82 (10000 VA, 8000 W) Width: 43.1 cm (17.2 in) Depth: 76.0 cm (30.0 in) Height: 26.2 cm (10.5 in), 6 EIA units Weight: 53 kg (117 lb) for Chassis, 7 kg (37 lb) for each internal battery tray (4 trays per E82) To assure installability and serviceability in non-ibm industry-standard racks, review the installation planning information for any product-specific installation requirements. Operating environment Model E30 Operating temperature: 0 C to 40 C (32 F to 104 C) Storage temperature: 0 C to 25 C (32 F to 77 C) Relative humidity: 0% to 90%, noncondensing Audible noise at one meter: Less than 45 dba (on utility); less than 50 dba (on battery) Input voltage: Autosensing to nominal voltage of 208, 220, 230, or 240 V single phase Input voltage range: 160 to 288 V single phase (without using batteries) Output voltage: 120/208 (with 6570 PPDM), 208, 220, 230, or 240 V single phase IBM United States Announcement 108-068 IBM is a registered trademark of International Business Machines Corporation 5
Model E33 Operating temperature: 10 C to 40 C (32 F to 104 F) Storage temperature: -15 C to +50 C (5 F to 122 F) Relative humidity: 5% to 95%, noncondensing Audible noise at one meter: <45 dba Operation elevation: 0 to +3000 m (0 to 10,000 ft) Input voltage: Autosensing to nominal voltage of 208, 220, 230, or 240 V single phase Input voltage range: 160 to 288 V single phase (without using batteries) Output voltage: -10% to +6% of nominal voltage on utility, +/- 5% on battery Model E64 Operating temperature: 0 C to 40 C (32 F to 104 C) Storage temperature: 0 C to 25 C (32 F to 77 C) Relative humidity: 5% to 90%, noncondensing Audible noise at one meter: Less than 45 dba (on utility); less than 50 dba (on battery) Input voltage: Autosensing to nominal voltage of 208, 220, 230, or 240 V single phase Input voltage range: 160 to 288 V single phase (without using batteries) Output voltage: 120/208 (with 6571 PPDM), 208, 220, 230, or 240 V single phase Model E65 Operating temperature: 0 C to 40 C (32 F to 104 F) Storage temperature: 0 C to 25 C (32 F to 77 F) Relative humidity: 0% to 90%, noncondensing Audible noise at one meter: Less than 45 dba (on utility); less than 50 dba (on battery) Input voltage: Autosensing to nominal voltage of 208, 220, 230, or 240 V single phase Input voltage range: 160 to 288 V single phase (without using batteries) Output voltage: -10% to +6% of nominal voltage on utility, +/- 5% on battery Model E82 Operating temperature: 0 C to 40 C (32 F to 104 F) Storage temperature: -20 C to 50 C (-4 F to 122 F) Relative humidity: 0% to 95%, noncondensing Audible noise at one meter: Less than 55 dba (on utility) Input voltage: Autosensing to nominal voltage of 208, 220, 230, or 240 V single phase Output voltage: -10% to +6% of nominal voltage on utility, +/- 5% on battery Software requirements: If you want the Uninterruptible Power Supply to communicate with your computer, refer to the following table to determine which communication option and/or software is correct for your application. Feat 2939 Feat 2934 X-Slot Powerware Software ConnectUPS Relay/ Suite CD and Web/SNMP Serial Serial Cable Kit Kit IBM United States Announcement 108-068 IBM is a registered trademark of International Business Machines Corporation 6
IBM i5 / iseries(tm) server (1) X(1) IBM i5 / iseries server and Serial (TTY) server (1) (Windows(R), Linux(TM), AIX(R), and so on) X X(1) IBM p5 / pseries(r), OpenPower(R) or xseries(r) server with single Serial (TTY) connection X IBM p5 / pseries, OpenPower with LPARs and/or Network (Web server) connection X X (1) Uninterruptible Power Supply monitoring is a standard feature of the i5/iseries (AS/400(R)) operating system. For logical partitions of the p5/pseries operating system, a NetWatch client will be loaded onto each LPAR. Corequisite: Feature number 2934, ConnectUPS Web/SNMP/xHub network card. The 9910 solutions come with a complimentary Powerware Software Suite CD which incorporates power technology with the control software you need for effective network monitoring, analysis, power management, SNMP, and power supply system remote shutdown. Software suite contents include LanSafe and NetWatch software and a 30-day trial version of PowerVision. Powerware Extensions for IBM Director and MultiView are downloadable from the Web. With comprehensive Network Power Management and 9910 solutions from Eaton, you can realize key benefits of: Real-time information on network-wide power quality and events that affect system availability Control of power connected to individual or network devices Continuous clean power to each device Automatic and graceful shutdown of individual or network devices during extended power outages Monitoring to analyze and diagnose network problems Software to application matrix Powerware Software Powerware Extension Application LanSafe V5 NetWatch for IBM Director Single pseries (serial/tty) non-lpar X Single pseries (network) non-lpar X(1) X(1) Single pseries (LPAR) X(1) Multiple pseries (non-lpar) X X(1) Multiple pseries (LPAR) X(1) IBM Director network device X(1) (1) Corequisite: Feature number 2934, ConnectUPS Web/SNMP/xHub network card. Note: Uninterruptible Power System for iseries applications utilize OS/400 power system monitoring functions. Application comparison matrix IBM United States Announcement 108-068 IBM is a registered trademark of International Business Machines Corporation 7
Software Monitoring Shutdown GUI E-mail LanSafe Y Y Y Y NetWatch -- Y -- N/N MultiView(1) Y Y Y ConnectUPS Web/SNMP Card Y(2) Y(3) Y Y/Y UPS application LanSafe NetWatch ConnectUPS Web/SNMP Card SSL/SSH security N/N N/N Y/Y (1) Corequisite: Feature number 2934, ConnectUPS Web/SNMP/xHub network card. (2) Via Web browser, LanSafe, or Network Management System. (3) In conjunction with NetWatch software. Delivering a strong power management and power system monitoring tool to your desktop, the MultiView monitoring program uses your existing Internet Explorer and helps increase its functionality through several valuable features: Allows the user to view multiple Web sites simultaneously within a single browser window Searches for and automatically adds browser pages of connected feature number 2934 ConnectUPS Web/SNMP/xHub cards as well as Status@aGlance monitoring feature from the Powerware LanSafe V5 software The following are some of the operating systems supported by LanSafe V5: AIX V4.1 and 4.3.2 for RISC; V4.3.3, 5.1, 5.2, and 5.3 for Power PC Red Hat Linux V7.1, 7.2, 7.3, 8.0, and 9.0 SUSE Linux V7.2, 8.0, and 8.2 SUSE Enterprise Linux Server 8 Windows 2000, Windows 98, Windows Me, Windows NT 4.0, Windows XP (Home and Professional), Windows Server 2003 (Standard, Web, and Enterprise), and Windows Vista The following are some of the operating systems supported by NetWatch: IBM AIX V4.x and 5.x (Power PC) Linux kernel V2.0 and higher (x86 and AXP) Windows 9x, NT, 2000, and XP The following are operating systems supported by MultiView: Windows 98, Me, 2000, and XP For a listing of current supported operating systems and information about Powerware power system, network, and enterprisewide monitoring and control software, refer to the following Web site http://www.powerware.com/software/products.asp Planning information Customer responsibilities: The 9910 Models E30, E33, E64, E65, and E82 are designated as customer setup, which includes installation of two battery trays for the E64 and E65 and four IBM United States Announcement 108-068 IBM is a registered trademark of International Business Machines Corporation 8
battery trays for the E82. If any of the above models are not ordered with the iseries and pseries rack, the client will be responsible for the installation of external cables, the power system module, and the battery module. Clients who request IBM service personnel to perform these activities are subject to a charge. Client responsibilities include: Adequate site and system planning and preparation Receipt, unpacking, and placement of the system unit Ordering, installing, and maintaining cables with associated parts for attaching to the pseries model Using and following the problem determination procedures in the operators guide Installing power system management software and setting power system run-time parameters Installing feature number 2934 and 2939 interface cards Cable orders 9910 Model E82 Power (electrical) cables: The E82 unit uses Hubbell style 60 amp input and output connectors common with the PDU power cord feature 6492. The E82 also provides four IEC 320 C19 outputs. 9910 Model E30 Power (electrical) cables: The input (mains) power connection to the 9910-E30 is an IEC-320-C20, 16 amp connector. The input (mains) power cord from the power system to the utility (mains) is determined based upon the use of a tower or rack configuration, and upon country or locality. Refer to the following 9910-E30 input power cord table: Feature number Plug type Plug description Length Used when PDU has 6654/6655 cord-breaker for 20 amp: 2975 12 NEMA L6-30 6 ft/1.8 m Used when PDU has 6656 cord-breaker for 20 amp: 2976 46 IEC309 (P+N+G) 4.3 m The following should be used for tower installation or if there is no rack PDU 20 amp service: 9860 11 NEMA L6-20 14 ft/4.4 m 9861 11 NEMA L6-20 6 ft/1.8 m 9866 18 CEE7 VII 14 ft/4.4 m 9867 22 SABS 164 14 ft/4.4 m 9868 25 CEI 23-16 14 ft/4.4 m 9871 46 IEC309 (P+N+G) 16A 14 ft/4.4 m 9872 32 SII 32-1971 14 ft/4.4 m 9874 54 SAA-AS 3112 14 ft/4.4 m When the 9910-E30 is employed in a rack installation (iseries or pseries) or in a tower configuration, the E30 output (receptacle) configuration is four IEC-320-C13, 10 amp and one IEC-320-C19, 16 amp. The 9910-E30 (Accessory Kit) includes five output power cables consisting of four IEC-320-C13 to C14 (6 ft length) and one IEC-320-C19 to C20 (9 ft length). When the 9910-E30 is employed in a tower configuration in NEMA-type countries, the E30 will include one NEMA-type PowerPass Distribution Module (PPDM), feature number 6570, which contains the following output (receptacle) connections. IBM plug types supported are referenced. Feature 6570 output connection table NEMA type Qty provided IBM plug type(s) supported 5-15/5-2 2 4 IBM United States Announcement 108-068 IBM is a registered trademark of International Business Machines Corporation 9
6-15/6-20 4 5/29 L6-15 2 10 If the plug type selected for the equipment to be protected by the 9910-E30 is not contained in this table, change the plug type on the equipment to match plug types available with feature number 6570. Power electrical cable installation diagrams are at the following Web sites http://www.oem.powerware.com/ibm-ups/pdf/nemadiagm.pdf Feature 6644 (external battery module) The input power to the 6644 is DC and is provided by the E30. Connection of the 6644 DC cable (Anderson type DC connector) is the responsibility of the customer and is performed at installation. Feature number 6644 is a line-up-and-match cabinet connected to the E30 cabinet or installed in the rack with the E30. Communication cables: One server to power system serial TTY interface cable DB9M to DB9F (6 ft/1.8 m length) is included with the E30 (contained in the E30 Accessory Kit carton) for all (iseries and pseries) orders. The E30 includes a single serial port (DB9) contained on a removable ConnectUPS X-Slot interface card. Optional communications features (#2934 or #2939) can replace the single-port serial card. A maximum of one feature number 2934 or 2939 is supported. The optional feature number 2934 (ConnectUPS Web/SNMP/xHub card) includes one power system to Web card configuration cable RJ45 to DB9M (6 ft/1.8 m length). Note: This is required if using LPAR on pseries. Minimum: 0. Maximum: 1 per E30. The optional feature number 2939 (X-Slot Relay/Serial Kit) includes one iseries/as/400 to UPS interface cable (30 ft/9.2 m length) and one serial TTY Server to power system interface cable (6 ft/1.8 m). This feature number is required with iseries orders. Minimum: 0 per E30. Maximum: 1 per E30. This feature replaces feature 2936. 9910 Model E33 The input (mains) power connection to the 9910-E33 is an IEC-320-C20, 16 amp connector. The input (mains) power cord from the UPS to the utility (mains) is determined based upon the rack PDU, and country or locality. Refer to the following 9910-E33 input power cord table: Feature number Plug type Plug description Length Used when PDU has 6654/6655 cord-breaker for 20 amp: 2975 12 NEMA L6-30 6 ft/1.8 m Used when PDU has 6656 cord-breaker for 20 amp: 2976 46 IEC309 (P+N+G) 4.3 m The following may be used when there is no rack PDU 20 amp service: 9860 11 NEMA L6-20 14 ft/4.4 m 9861 11 NEMA L6-20 6 ft/1.8 m 9866 18 CEE7 VII 14 ft/4.4 m 9867 22 SABS 164 14 ft/4.4 m 9868 25 CEI 23-16 14 ft/4.4 m 9871 46 IEC309 (P+N+G) 16A 14 ft/4.4 m 9872 32 SII 32-1971 14 ft/4.4 m 9874 54 SAA-AS 3112 14 ft/4.4 m 9875 64 Type 64 14 ft/4.4 m A power cord provided with the power system (accessory kit) will provide the connection between the E33 and the 7188/5889 and 9188/7109 PDU. The 9910-E33 (Accessory Kit) includes five output power cables consisting of four IEC-320-C13 to C14 (6 ft length) and one IEC-320-C19 to C20 (9 ft length). Output receptacles IEC 320-C13 (Qty 9) IEC 320-C19 (Qty 1) Input plug/connector C20 Communication cables: One server to power supply serial TTY interface cable DB9M to DB9F (6 ft/1.8 m length) is included with the E33 (contained in the E33 Accessory Kit carton) for all IBM United States Announcement 108-068 IBM is a registered trademark of International Business Machines Corporation 10
(iseries and pseries) orders. The E33 includes a single serial port (DB9) contained on a removable ConnectUPS X-Slot interface card. Optional communications features (#2934) will replace this single-port serial card. A maximum of one feature number 2934 is supported. The optional feature number 2934 (ConnectUPS Web/SNMP/xHub card) includes one power system to Web card configuration cable RJ45 to DB9M (6 ft/1.8 m length). Note: This is required if using LPAR on pseries. Minimum: 0. Maximum: 1 per E33. The optional feature number 2939 (X-Slot Relay/Serial Kit) includes one iseries/as/400 to power system interface cable (30 ft/9.2 m length) and one serial TTY Server to power system interface cable (6 ft/1.8 m). This feature number is required with iseries orders. Minimum: 0 per E33. Maximum: 1 per E33. This feature replaces feature 2936. 9910 Model E64 Power (electrical) cables: The input (mains) power connection to the 9910-E64 is a NEMA L6-30AR (30A) connector. The input (mains) power cord from the power system to the utility (mains) is determined based upon country or locality. Refer to the following 9910-E64 input power cord table: Feature number Plug type Plug description Length 1420 12 NEMA L6-30 14 ft/4.4 m 1421 12 NEMA L6-30 6 ft/1.8 m 1422 40 RS 3750 6 ft/1.8 m 1423 40 RS 3750 14 ft/4.4 m 1424 46 IEC309 (P+N+G) 32A 14 ft/4.4 m 1426 PDL PDL 14 ft/4.4 m 1427 PDL PDL-NZ 14 ft/4.4 m When the E64 is used as a rack model and the PDU is a 7188/5889 or 9188/7109 and the plug is an L6-30 (#6654), the 6654 can plug directly into the E64. For those PDUs with other than the 6654 cord, feature number 9910-2972 or 2973 is required. The E64 has only one L6-30 outlet. A PDU is required for an E64 in a rack. When the 9910-E64 is employed in a tower configuration in NEMA-type countries, the E64 requires one NEMA-type PowerPass Distribution Module (PPDM), IBM feature number 6571, which contains output (receptacle) connections described in the feature number 6571 output connection table. IBM plug types supported are referenced. Feature 6571 output connection table NEMA type Qty provided IBM plug type(s) supported 5-15/5-20 2 4 6-15/6-20 4 5/29 L6-15 2 10 L6-30 1 12 If the plug type selected for the equipment to be protected by the 9910-E64 is not contained in this table, change the plug type on the equipment to match plug types available with feature number 6571. When the 9910-E64 is employed in a tower configuration, in IEC type countries, the E64 requires one IEC-type PowerPass Distribution Module (PPDM), IBM feature number 6572, which contains output receptacle connections described in the feature number 6572 output connection table. IBM plug types supported are referenced. The feature number 6572 contains two IEC-320-C19 to C20 (9 ft length) and six IEC-320-C13 to C14 (6 ft length) power cords, which are located in the 6572 carton. Feature 6572 output connection table NEMA type Qty provided IBM plug type(s) supported IEC-320-C13 (10A) 8 IEC-320-C19 (16A) 4 IEC309 (P+N+G) (32A) 1 46 Power electrical cable installation diagrams are at the following Web site http://www.oem.powerware.com/ibm-ups/pdf/nemadiagm.pdf IBM United States Announcement 108-068 IBM is a registered trademark of International Business Machines Corporation 11
Feature 6645 (external battery module) The input power to the 6645 is DC and is provided by the E64. Connection of the 6645 DC cable (Anderson-type DC connector) is the responsibility of the customer and is performed at installation. Feature number 6645 is a line-up-and-match cabinet connected to the E64 cabinet or may be rack installed. Communication cables: One server to power system serial TTY interface cable DB9M to DB9F (6 ft/1.8 m length) and one power system to Web card configuration cable RJ45 to DB9M (6 ft/1.8 m length) are included with the E64 (contained in the E64 Accessory Kit carton) for all (iseries and pseries) orders. The E64 includes a single serial port (DB9) and a USB port. Both are contained on the backplane of the device. An empty ConnectUPS X-Slot interface port is available for optional communications feature 2934 or 2939. Communications is employed in an "or" configuration: serial or USB or ConnectUPS card. A maximum of one feature number 2934 or 2939 is supported. The optional feature number 2934 (ConnectUPS Web/SNMP/xHub card) includes one power system to Web card configuration cable RJ45 to DB9M (6 ft/1.8 m length). Note: This is required if using LPAR on pseries. Minimum: 0. Maximum: 1 per E64. The optional feature number 2939 (X-Slot Relay/Serial Kit) includes one iseries/as/400 to power system interface cable (30 ft/9.2 m length) and one serial TTY Server to power system interface cable (6 ft/1.8 m). Note: This feature number is required with iseries orders. Minimum: 0 per E64. Maximum: 1 per E64. This feature replaces feature 2936. 9910 Model E65 Power (electrical) cables: The input (mains) power connection to the 9910-E65 is a NEMA L6-30P on a 3 ft/0.9 m cord with a 30A connector. The input (mains) power cord from the power system to the utility (mains) is determined based upon country or locality. Refer to the following 9910-E65 input power cord table: Feature number Plug type Plug description Length 1420 12 NEMA L6-30 14 ft/4.4 m 1421 12 NEMA L6-30 6 ft/1.8 m 1422 40 RS 3750 6 ft/1.8 m 1423 40 RS 3750 14 ft/4.4 m 1424 46 IEC309 (P+N+G) 32A 14 ft/4.4 m 1426 PDL PDL 14 ft/4.4 m 1427 PDL PDL-NZ 14 ft/4.4 m When the PDU is feature number 7188/5889, 9188/7109, or 9406/7014-6654, the 6654 PDU power cord can plug into the E65 L6-30 output receptacle. When the PDU power cord is not 6654, feature number 9910-2972 or 9910-2973 must be used to connect the PDU power cord to the L6-30 output receptacle. A second or third PDU may be supported by using feature code 9910-2974 to connect the PDU input to a C19 outlet on the back of the E65. PDU to power system power cord table Feature number Plug type Receptacle type Length 9910-2972 NEMA L6-30 Burndy UTG 14 ft/4.3 m 9910-2973 NEMA L6-30 Burndy UTG 4 ft/1.2 m 9406/7014-6654 NEMA L6-30 Burndy UTG 14 ft/4.3 m Power electrical cable installation diagrams are at the following Web site http://www.oem.powerware.com/ibm-ups/pdf/nemadiagm.pdf Communications cables: One server to power system serial TTY interface cable DB9M to DB9F (6 ft/1.8 m length) and one UPS to Web card configuration cable RJ45 to DB9M (6 ft/1.8 m length) are included with the E65 (contained in the E65 Accessory Kit carton) for all iseries and pseries orders. The E65 includes a single serial port (DB9) and a USB port; both are contained on the backplane of the device. An empty ConnectUPS X-Slot interface port is available for optional communications features (#2934 and #2939). Communications is employed in an "or" configuration: serial or USB or ConnectUPS card. A maximum of one feature number 2934 or 2939 is supported. IBM United States Announcement 108-068 IBM is a registered trademark of International Business Machines Corporation 12
The optional feature number 2934 (ConnectUPS Web/SNMP/xHub card) includes one power system to Web card configuration cable RJ45 to DB9M (6 ft/1.8 m length). Note: This is required if using LPAR on p5/pseries. Minimum: 0 per E65. Maximum: 1 per E65. The optional feature number 2939 (X-Slot Relay/Serial Kit) includes one iseries (AS/400) to power system interface cable (30 ft/9.2 m length) and one serial TTY Server to power system interface cable (6 ft/1.8 m). Note: This feature number is required with iseries orders. Minimum: 0 per E65. Maximum: 1 per E65. This feature replaces feature 2936. Security, auditability, and control The customer is responsible for evaluation, selection, and implementation of security features, administrative procedures, and appropriate controls in application systems and communications facilities. Terms and conditions IBM credit corporation financing: No Warranty period This product is available for purchase under the terms of the IBM Customer Agreement. IBM hardware products are manufactured from new parts, or new and used parts. In some cases, the hardware product may have been previously installed. Regardless, IBM warranty terms apply. Models E30, E33, E64, and E65 have a five-year Advanced Element Exchange Warranty (including battery) provided by Eaton with IBM as point of contact. When a type of service involves the exchange of a machine part, the replacement may not be new, but will be considered equivalent to new. Model E82 has a five-year Advanced Element Exchange Warranty (including battery) provided by Eaton with IBM as point of contact. When a type of service involves the exchange of a machine part, the replacement may not be new, but will be considered equivalent to new. Warranty service IBM 9910 Models E30, E33, E64, E65, and E82 provide a premium Element Exchange Warranty. In case of problems with the UPS, contact IBM Service Support. IBM will coordinate remote diagnostics and manage the Element Exchange Warranty, if necessary. If a replacement element is required, the UPS manufacturer will process and ship the request the same day if the request is received before noon (12:00 p.m.) local time. After noon, the replacement element will be shipped the following business day. The replacement element will be next-day air service (same type of carrier used in the U.S., for example, Federal Express, Airborne Express). The shipping costs to and from the client location are the responsibility of the UPS manufacturer. Advanced Element Exchange Warranties DO NOT include onsite service unless specifically noted in writing at the time of equipment sale. Client responsibility: For 9910 Models E30, E33, E64, E65, and E82 the clients' responsibilities for element exchange are: Receipt, unpacking, installation, and exchange of the defective element. Packaging of the defective element in the container received with the replacement element. Following the instructions provided for return of the defective element. Returning the defective element so that it is received at Powerware UPS depot center within the established time from the arrival of the replacement. Technical information can also be accessed at the following Web site http://www.powerware.com/ibm Warranty service is available from: IBM United States Announcement 108-068 IBM is a registered trademark of International Business Machines Corporation 13
IBM Field Support Services Center at 800-IBM-SERV (426-4968) Warranty service upgrades During the warranty period, warranty service upgrades provide an enhanced level of On-site Service for an additional charge. A warranty service upgrade must be purchased during the warranty period and is for a fixed term (duration). It is not refundable or transferable and may not be prorated. If required, IBM will provide the warranty service upgrade enhanced level of On-site Service acquired by the customer. Service levels are response-time objectives and are not guaranteed. IBM will attempt to resolve your problem over the telephone or electronically by access to an IBM Web site. You must follow the problem determination and resolution procedures that IBM specifies. Scheduling of service will depend upon the time of your call and is subject to parts availability. On-site Service: IBM will repair the failing machine at your location and verify its operation. You must provide a suitable working area to allow disassembly and reassembly of the IBM machine. The area must be clean, well-lit, and suitable for the purpose. The following service selections are available as warranty upgrades for your machine. 9 hours per day, Monday through Friday, excluding holidays, 4-hour average, same-business-day response 24 hours per day, 7 days a week, 4-hour average response 24 hours per day, 7 days a week, 2-hour average response Customer replaceable units (CRUs) may be provided as part of the machine's standard warranty CRU service except that you may install a CRU yourself or request IBM installation, at no additional charge, under one of the On-site Service levels specified above. For additional information on the CRU service, refer to the Warranty Information. Maintenance services If required, IBM provides repair or exchange service depending on the types of maintenance service specified for the machine. IBM will attempt to resolve your problem over the telephone or electronically, via an IBM Web site. You must follow the problem determination and resolution procedures that IBM specifies. Scheduling of service will depend upon the time of your call and is subject to parts availability. Service levels are response-time objectives and are not guaranteed. The specified level of maintenance service may not be available in all worldwide locations. Additional charges may apply outside IBM's normal service area. Contact your local IBM representative or your reseller for country- and location-specific information. The following service selections are available as maintenance options for your machine type. On-site Service: IBM will repair the failing machine at your location and verify its operation. You must provide a suitable working area to allow disassembly and reassembly of the IBM machine. The area must be clean, well-lit, and suitable for the purpose. 9 hours per day, Monday through Friday, excluding holidays, next-business-day response 9 hours per day, Monday through Friday, excluding holidays, 4-hour average response 24 hours per day, 7 days a week, 4-hour average response 24 hours per day, 7 days a week, 2-hour average response CRU Service: If your problem can be resolved with a CRU (for example, keyboard, mouse, speaker, memory, or hard disk drive), and depending upon the maintenance service offerings in your geography, IBM will ship the CRU to you for you to install. CRU information and replacement instructions are shipped with your machine and are available from IBM upon your request. Based upon availability, CRUs will be shipped for next-business-day delivery. IBM specifies, in the materials shipped with a replacement CRU, whether a defective CRU must be returned to IBM. When return is required, return instructions and a container are shipped with the replacement CRU and you may be charged for the replacement CRU if IBM does not receive the defective CRU within 15 days of your receipt of the replacement. CRUs may be provided as part of the machine's standard maintenance service except that you may install a CRU yourself or request IBM installation, at no additional charge, under any of the IBM United States Announcement 108-068 IBM is a registered trademark of International Business Machines Corporation 14
On-site Service levels specified above. Courier or Depot Service: You must disconnect the failing machine for collection arranged by IBM. IBM will provide you with a shipping container for you to return your machine to a designated service center. A courier will pick up your machine and deliver it to the designated service center. Following its repair or exchange, IBM will arrange the return delivery of the machine to your location. You are responsible for its installation and verification. Customer Carry-In or Mail-In Service: You will deliver or mail, as IBM specifies (prepaid, unless IBM specifies otherwise) the failing machine suitably packaged to a location IBM designates. After IBM has repaired or exchanged the machine, IBM will make it available for your collection or, for Mail-In Service, IBM will return it to you at IBM's expense, unless IBM specifies otherwise. You are responsible for the subsequent installation and verification of the machine. Machine Exchange Service: IBM will initiate shipment of a replacement machine to your location. You are responsible for its installation and verification of operation. You must pack the failed machine into the shipping container that contained the replacement machine and return the failed machine to IBM. Transportation charges, both ways, are paid by IBM. You may be charged for the replacement machine if IBM does not receive the failed machine within 15 days of your receipt of the replacement. Non-IBM parts support Under certain conditions, IBM repairs selected non-ibm parts at no additional charge for machines that are covered under warranty service upgrades or maintenance services. IBM Service provides hardware problem determination on non-ibm parts (for example, adapter cards, PCMCIA cards, disk drives, memory) installed within IBM machines covered under warranty service upgrades or maintenance services and provides the labor to replace the failing parts at no additional charge. If IBM has a Technical Service Agreement with the manufacturer of the failing part, or if the failing part is an accommodations part (a part with an IBM FRU label), IBM may also source and replace the failing part at no additional charge. For all other non-ibm parts, customers are responsible for sourcing the parts. Installation labor is provided at no additional charge, if the machine is covered under a warranty service upgrade or a maintenance service. Usage plan machine: No IBM hourly service rate classification: Two These machines are not covered under the IBM Maintenance Agreement. Contact your local IBM Services branch office for post-warranty options. When a type of service involves the exchange of a machine part, the replacement may not be new, but will be in good working order. Field-installable features: Yes Model conversions: No Machine installation: Customer setup. Customers are responsible for installation according to the instructions IBM provides with the machine. Graduated program license charges apply: No. These products do not contain licensed internal code or licensed machine code. Prices Prices are available upon request. Machine Feature Description type Model number CSU Powerware 9125 3 kva tower or rack-mount 9910 E30 Yes Powerware 9125 3 kva Battery Module 9910 E30 6644 Yes IBM United States Announcement 108-068 IBM is a registered trademark of International Business Machines Corporation 15
Powerware 5125 3000 VA Rackmount 9910 E33 Yes Powerware 5125 3000 VA Battery Module 9910 E33 6643 Yes Powerware 9125 6 kva tower or rack-mount 9910 E64 Yes Powerware 5125 5 kva Rack Mount (C13/C19/L6-30 Outlets) 9910 E65 Yes Powerware 9125 6 kva Battery Module 9910 E64/E65 6645 Yes Powerware 9140 10 kva rack-mount 9910 E82 Yes Powerware 9140 10 kva Battery Module 9910 E82 6646 Yes Rack Cont. Specify: 9910/E82-6EIA 7014 T00,T42 0320 Yes Rack Cont. Specify: 9910/6646-3EIA 7014 T00/T42 0321 Yes NC = No charge CSU = Customer setup Field Plant MES MES install install MES removal add only only removal charge charge N N N NC NC For ServiceElect (ESA) maintenance service charges, contact IBM Global Services at 888-IBM-4343 (426-4343). Order now To order, contact the Americas Call Centers, your local IBM representative, or your IBM Business Partner. To identify your local IBM representative or IBM Business Partner, call 800-IBM-4YOU (426-4968). Phone: 800-IBM-CALL (426-2255) Fax: 800-2IBM-FAX (242-6329) Internet: callserv@ca.ibm.com Mail: IBM Teleweb Customer Support ibm.com Sales Execution Center, Americas North 3500 Steeles Ave. East, Tower 3/4 Markham, Ontario Canada L3R 2Z1 Reference: YE001 The Americas Call Centers, our national direct marketing organization, can add your name to the mailing list for catalogs of IBM products. Note: Shipments will begin after the planned availability date. Trademarks iseries is a trademark of International Business Machines Corporation in the United States or other countries or both. AIX, xseries, pseries, OpenPower, AS/400, OS/400, and SAA are registered trademarks of International Business Machines Corporation in the United States or other countries or both. Windows NT is a trademark of Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation. Linux is a trademark of Linus Torvalds in the United States, other countries or both. Other company, product, and service names may be trademarks or service marks of others. IBM United States Announcement 108-068 IBM is a registered trademark of International Business Machines Corporation 16
This announcement is provided for your information only. For additional information, contact your IBM representative, call 800-IBM-4YOU, or visit the IBM home page at: http://www.ibm.com IBM United States Announcement 108-068 IBM is a registered trademark of International Business Machines Corporation 17