Terminal Relay types. Common note. Terminal Relay/Terminal SSR Mounted relays. Compact Terminal Relays/Terminal SSRs with four outputs

Similar documents
G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

Solid State Relays with Failure Detection Function

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

S82S (3/7.5-W Models)

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

CSM_PYF S/P2RF- -S_DS_E_2_5

Connecting Sockets, Mounting Brackets, DIN Rails

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

Model Number Structure

G9H. Ordering Information. Hybrid Power Relay. List of Model. Accessories (Order Separately) Connecting Socket Mounting Plate

Model Number Structure

Number of input channels

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

Model Number Structure

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

Model A7BS

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

(75 to 264 VAC) 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC

Model Number Structure

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Type High-sensitivity. Medium-sensitivity models models Sensed current 30 ma (fixed) 100 ma/200 ma 200 ma/500 ma 500 ma/1,000 ma Operating time

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

M22. Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Indicator (Cylindrical 22/25-dia.) List of Models. Model Number Structure

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

Model Number Structure

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

Probe Pin XP3A. Electroplated Probe Pin for High Reliability. Feature. List. New Product News

Model NPN output PNP output Standard. configuration

Features various encoder interfaces and controls multiple analog servo drives at high speeds

Electroformed Probe Pins XP3A

Name Specifications Model Standards RS-422A Converter. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

E4C-UDA CSM_E4C-UDA_DS_E_12_2

NE1A-SCPU Series. Safety Network Controller. Achieve Safety Control through Programming. Ordering Information. Specifications.

E6J-C. Ultracompact Rotary Encoder with External Diameter of 20 mm. Ultracompact 20-mm-dia. Incremental Rotary Encoder. Ordering Information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

With operation indicators **LY2N-CR **LY2ZN-CR

CS1W-B7A. CS-series B7A Interface Unit. It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort,

Conductive Level Controller

Indicator (Square) Ultra Bright LED Type

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

ZN-CTX/-CTM. Portable Power Monitor. Easy and Quick Checking Power at the Worksite. Ordering Information. Portable Power Monitor

Model Number Structure

D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure

Model Number Structure

Dimension A. Dimension B

E2K-X4ME1 2M E2K-X4ME2 2M

Model Number Structure

3. Input KJ: Thermocouple P: Platinum resistance thermometer T: Thermocouple/platinum resistance thermometer (universal-input)

NJ-Series Power Supply Unit NJ-PA/PD

M16-J M16-A M16-T

Model Number Structure

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Model Number Structure

Handheld Reader Writer

Model Number Structure

Aluminum-detecting Proximity Sensor (Separate Amplifier Type)

NPN output. 200 mm. Type Cable length Model Remarks

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure

Indicator (Square) Ultra Bright LED Type

Power supply voltage Output configuration Output phases Resolution (pulses/rotation) Model. 100, 200, 360 E6A2-CWZ5C (resolution) 0.

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)

PRODUCT SPECIFICATION. PC Board Relays. Series.

Photoelectric Sensor

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

Model Number Structure

Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor E2J-W10MA 1M E2J-W20MA 1M. E2J-JC4A Amplifier Unit

Model NPN output PNP output Standard. configuration

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

Model Number Structure. Ordering Information. Switch Mode Power Supply S82K (3/7.5/15/30/50/90/100-W Models) Model Number Legend.

Ordering Information. Interface Converter K3SC. List of Models

EE-SX97 40% Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. Slot-type Photomicrosensor.

NX-TS. NX-series Temperature Input Unit

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series Smart Slave Analog I/O Terminals.

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Snap-in (front mounting) Locking type. Terminals Solder terminals *1 Color Light gray Black A7BL-207 *2 A7BL *2

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4 40 XW2B-40G5 *1 50 XW2B-50G5 60 XW2B-60G5 40 XW2B-40G5-T

D4GS-N CSM_D4GS-N_DS_E_7_4

Reliable Detection Unaffected by PCB Holes or Notches. PCB Sensors. Ordering Information. Sensors [Refer to Dimensions on page 4.

Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range.

Switching Frequency Test Conditions (AC3/AC4/AC53-a)

Knob-type Selector Switches

Classification Applicable models Specification Type Model

Transcription:

Terminal Relay/Terminal SSR G6B-@@ND/G3S CSM_G6B- ND_G3S_DS_E Compact Terminal Relays/Terminal SSRs with four outputs Easy wiring with separated input/output terminals. LED operation indicator. Mounts either on DIN track or with screws. Special socket used for easy Relay/SSR replacement (except for high-reliability models). Terminal Relays Equipped with four G6B Mini-relays that are compact, highly sensitive, and highly resistant to dielectric surges, and that can switch 5 amps of power. Sealed plastic construction used for relays. Built-in diode for absorption of coil surges. UL and CSA certification for standard models (except for highreliability models). VDE certification for G6B-BND/7BND/8BND for /. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to Safety Precautions for All Relays and Safety Precautions on page 7 and. Terminal SSRs Easy-to-use SSR block that combines four compact G3S SSRs, sockets, and heat sink in one unit. Terminal Relay types G6B-@@ND Mounted relays: Electromagnetic Relay...page G3S Mounted relays: Solid State Relay...page 8 Common note Options for the G6B-CB, G6B-@@ND, and G3S...page Mounted relays Relays and SSRs cannot be mounted together.

Terminal Relay G6B-@@ND Compact Terminal Relay with Independent Outputs Equipped with four G6B Mini-relays that are compact, highly sensitive, and highly resistant to dielectric surges, and that can switch 5 amps of power. Sealed plastic construction used for relays. Easy wiring with separated input/output terminals. Special P6B Mounting Socket used to facilitate maintenance (except for high-reliability models). UL and CSA certification for standard models (except for high-reliability models). VDE certification for G6B-BND/7BND/8BND for /. DIN Track mounting, and screw mounting models are available. SSR-equipped G3S models are also available. Number Structure For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to Safety Precautions for All Relays. Number Legend G6B-@@@@ND 3 Note: UL508 and CSA requirements met by standard models.. Number of Poles : poles (PST-NO standard circuit) 7: poles (PST-NO long-life circuit) 8: poles (PST-NO high-reliability circuit) Ordering Information List of s Equipped with operation indicator and diode to absorb coil surge. Mounting None: DIN Track or screw mounting F: Screw mounting 3. Input Terminal B: Phillips screw terminals ( independent points) B: Flat-bladed screw terminals ( points with same common) P: Connector terminals ( independent points) Classification Contact form Mounting method Terminals Rated voltage PST (standard) DIN Track or screw mounting PST (long-life) PST (high reliability) DIN Track or screw mounting DIN Track or screw mounting PST (standard) Screw mounting Connector G6B-FPND 5 VDC Note:. For replacement relays, use relays with the same voltage specifications as the relays provided with the Terminal when it was purchased. Longer operating life can be achieved by replacing the G6B-@@ND with the G6B-7P-FD-US-P6B.. Standard models and long-life models are also available without relays mounted to the sockets 3. SSR-equipped G3S models are also available. Refer to information on the G3S (page 8). Terminal relay G6B-BND G6B-7BND When your order, specify the rated voltage. PST (standard) Screw mounting Flat-bladed screw terminal Socket P6BF-BND Also give the voltage specification. P6BF-BND Connection Sockets do not have specific approved standards. Phillips screw terminal G6B-BND 5 VDC Phillips screw terminal G6B-7BND 5 VDC Phillips screw terminal G6B-8BND 5 VDC G6B-FBND 5 VDC

Specifications G6B-@@ND Ratings Coil Ratings (per G6B Relay) Rated voltage 5 VDC Rated current 35.5 ma (3.) 9. ma 0.7 ma (0.3) Coil resistance 5 Ω 70 Ω,880 Ω Must operate voltage Must release voltage Max. voltage Power consumption Note:. Rated current and coil resistance were measured at a coil temperature of 3 C with a tolerance of ±0%.. Operating characteristics were measured at a coil temperature of 3 C. 3. The maximum allowable voltage is the maximum value of the allowable voltage range for the relay coil operating power supply. There is no continuous allowance.. Diodes to absorb coil surge are equivalent to S5688J (reverse voltage resistance: 600 V; forward current: A). 5. The values in parentheses are for the G6B-FBND and G6B-FPND. 6. The rated current includes the LED current. Contact Ratings Note: This value fulfills the P reference value of opening/closing at a rate of 0 times per min (ambient operating environment and determination criteria according to JIS C5). Characteristics Note:. The above values are initial values.. Measurement condition: A at 5 VDC 80% max. of rated voltage 0% min. of rated voltage 30% of rated voltage Approx. 00 mw Classification G6B-BND (standard), G6B-7BND (long-life) G6B-8BND (high-reliability) Load Rated load Resistive load (cosφ = ) 5 A at 50 VAC, 5Aat 30 VDC Inductive load (cosφ = 0., L/R = 7 ms) A at 50 VAC, A at 30 VDC Resistive load (cosφ = ) A at 50 VAC, Aat 30 VDC Inductive load (cosφ = 0., L/R = 7 ms) 0.5 A at 50 VAC, 0.5 A at 30 VDC Rated carry current 5 A A Max. switching voltage 380 VAC, 5 VDC Max. switching current 5 A A Max. switching power,50 VA, 50 W 500 VA, 60 W 500 VA, 60 W 5 VA, 5 W Error rate (reference value) (see note) 0 ma at 5 VDC ma at VDC Contact resistance (see note ) 00 mω max. Operate time 0 ms max. (approx. 3 ms) Release time 5 ms max. (approx. ms) Insulation resistance,000 MΩ min. (at 500 VDC) Dielectric strength,000 VAC, 50/60 Hz for min between coil and contacts,000 VAC, 50/60 Hz for min between contacts of different polarity,000 VAC, 50/60 Hz for min between contacts of same polarity 50 VAC, 50/60 Hz for min between coils of different polarity Vibration resistance Destruction: 0 to 55 to 0 Hz, 0.75-mm single amplitude (.5-mm double amplitude) Malfunction: 0 to 55 to 0 Hz, 0.75-mm single amplitude (.5-mm double amplitude) Shock resistance Destruction:,000 m/s (approx. 00G) Malfunction: 00 m/s (approx. 0G) Endurance Mechanical: 50,000,000 operations min. (at 8,000 operations/hr) Electrical: 00,000 operations min. (at,800 operations/hr, rated load) 500,000 operations min. for long-life at A 00,000 operations min for long-life at 5 A Ambient temperature Operating: 5 C to 55 C (with no icing or condensation) Storage: 5 C to 55 C (with no icing or condensation) Ambient humidity Operating: 35% to 85% Weight Approx. 75 g 3

Engineering Data Maximum Switching Power Switching current (A) AC inductive load (cosφ = 0.) DC inductive load (L/R = 7 ms) DC resistive load AC resistive load Endurance (x0 3 operations),000,000 500 300 00 Endurance G6B-7@ (long life) 50 VAC resistive load 30 VDC resistive load G6B-@ (standard) 50 VAC resistive load 30 VDC resistive load G6B-@ (standard) G6B-7@ (long-life) 50 VAC inductive load (cosφ = 0.) 30 VDC inductive load (L/R = 7 ms) G6B-8@ (high-reliability) 50 VAC resistive load 30 VDC resistive load Contact resistance (mω) G6B-@@ND Contact Reliability (High-reliability s) Switching voltage (V) Switching current (A) Number of switching operations ( 0 times) Note: Measurement values taken from production line samples have been plotted in graphs to provide this data. Use this data only as a guide. Relays are mass-produced, so allowances must be made for a certain amount of variation in measurement data.

Dimensions Note: All units are in millimeters unless otherwise indicated. Philip Screw Terminals G6B-BND G6B-7BND G6B-8BND Note: G6B-BND is shown in illustration (terminal numbers are incised). 6, M3.5 Phillips head screws Mounting Holes G6B-@@ND Terminal Arrangement/ Internal Connections 78 max. IN side Operation indicator Two, -dia. holes or M3.5 screw holes IN side 8 3 7 6 3 5 3 OUT side 65±0.3 OUT side 6 5 0 9 3 Flat Screw Terminal G6B-FBND 6 max. 3 max. 8 max. (30 max. for G6B-7@@ long-life model) Five, M.6 flat screws 3 max. max. 3 Eight, M3.5 Phillips head screws IN side Operation indicator OUT side 36±0. Mounting Holes Two, -dia. holes or M3.5 screw holes 3.5±0. Note: Do not reverse the coil polarity. 50±0.3 IN side OUT side Terminal Arrangement/ Internal Connections 6 5 3 COM 3 5 0 9 3 Note: Do not reverse the coil polarity. Connector Terminal G6B-FPND 3 max. IN side max. Mounting Holes Two, -dia. holes or M3.5 screw holes IN side Terminal Arrangement/ Internal Connections 8 7 6 5 3 60 max. 3 Operation indicator 50±0.3 3 Eight, M3.5 Phillips head screws OUT side 3.5±0. OUT side 6 5 0 9 3 Note: Do not reverse the coil polarity. 5

G6B-@@ND Accessories (Order Separately) Connection Socket (Can be Purchased Individually) P6BF-BND (with operation indicator) 6-M3.5 78 max. 3 max. 8 max. Replacement Relays Applicable terminal relay Rated voltage G6B-BND G6B-FBND G6B-FPND G6B-P-FD-US-P6B 5 VDC G6B-7BND G6B-7P-FD-US-P6B 5 VDC Note: Relays cannot be replaced for G6B-8BND, which is mounted directly to boards. Relay Mounting Products Name Relay Removal Tool Short Bars Mounting Track End Plate Spacer P6B-Y G6B--SB PFP-00N PFP-50N PFP-00N PFP-M PFP-S P6B-Y Relay Removal Tool G6B--SB Short Bars Short Bars are used to wire crossovers for common terminals for coils or contacts. G6B--C Terminal Covers (Two per set) Relay Removal Tool, Short Bar and Terminal Cover (Order Separately) Refer to Options for the G6B-CB, G6B-@@ND, and G3S on page. Relay Mounting Products (Order Separately) Refer to Common Sockets/Products Related DIN Tracks. 6

Safety Precautions G6B-@@ND Refer to Safety Precautions for All Relays. Wiring Be sure to turn OFF the power when wiring the Unit and do not touch the charged terminals of the Unit. Otherwise, an electric shock may result. Do not apply overvoltage to the input terminals. Otherwise, the Unit may malfunction or burn. Relay s Do not connect the Unit to loads exceeding the rated switching power (switching voltage or current). Otherwise, faulty insulation, contact weld, or faulty contact of Relays, or damage to Relays may result, or the Relays may malfunction or burn. The life of Relays varies with the switching condition. Test the Relays under the actual operating conditions before using the Relays within the permissible switching frequency. The use of deteriorated Relays may result in the faulty insulation of the Relays or cause the Relays to burn. Do not use the Unit in locations with inflammable gas. Otherwise, a fire or explosion due to the heat of the Relays or sparks from the Relays may result when they are switched. Correct Use Mounting Heat generated by the relays must be considered when gang-mounting. Space must be provided between the relays or other methods must be taken to maintain the relays ambient temperature at 55 C or lower. Replacement of Relays G6B-@@ND Use the P6B-Y Removal Tool as shown in the following diagram. Be sure to turn OFF the power to the Unit before replacing a Relay. Relays must be inserted straight onto the socket connector pins to ensure proper connection. G6B-8BND models (high reliability) are connected directly to boards to increase reliability and the relays are thus not replaceable. If relay replacement is necessary, use the P6BF-BND Terminal Sockets together with the G6B-8P Mini Relays. P6BF-BND Terminal Sockets are equipped with relay replacement sockets. Do not mount Relays that are different to one another in voltage. Relays Mounted G6B-@@ND standard: G6B-P-FD-US-P6B G6B-@@ND long life: G6B-7P-FD G6B-@@ND high reliability: G6B-8P-US Replacement is not possible for G6B-8BND. Mounted Relays Relays and SSRs cannnot be mounted together. Wiring Be sure to connect the input terminals with the correct polarity. Coil Voltage Be sure not to impose voltage exceeding the permissible voltage on the coil continuously. Do not use the relays when other inductive loads are connected in parallel with the coil input or when there are surges during power supply because the built-in diodes used to absorb surge may be destroyed. Do Not Use the Following Circuit Handling Inductive load G6B Coil Coil surge current absorption diode Do not drop, shock, or vibrate the Unit excessively. Otherwise, damage to the Unit may result or the Unit may malfunction. Make sure that all the Relays are properly mounted before use. Screw Tightening Torque Tighten each terminal screw to a torque described below. M3 terminal screw: 0. to 0.56 N m. M3.5 terminal screw: 0.78 to.8 N m. Tighten each mounting screw to a torque of 0.59 to 0.98 N m. Installation Environment Do not install the Unit in the following locations. Otherwise, damage to the Unit may result or the Unit may malfunction. Locations with direct sunlight. Locations with an ambient temperature range not within 0 C to 55 C. Locations with rapid temperature changes resulting in condensation or locations with relative humidity ranges not within 0% to 90%. Locations with corrosive or inflammable gas. Locations with excessive dust, salinity, or metal powder. Locations with vibration or shock affecting the Unit. Locations with water, oil, or chemical sprayed on the Unit. Disassembly, Repair, and Modification Do not disassemble, repair, or modify the Unit. Otherwise, an electric shock may result or the Unit may malfunction. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.0357. In the interest of product improvement, specifications are subject to change without notice. 7

Terminal SSR G3S Compact Terminal SSR with Outputs Easy-to-use SSR block that combines four compact G3S SSRs, sockets, and heat sink in one unit. Easy wiring with separate I/O terminal construction. LED operation indicator. Special socket used for easy Relay replacement. Mounts either on DIN track or with screws. Electromagnetic relay-equipped G6B-@@ND models are also available. Refer to Safety Precautions for All Relays. Ordering Information List of s When your order, specify the rated voltage. Contact configuration Heat sink Built-in SSRs Zero cross function Applicable output load Rated voltage Four SPST-NO relays Yes G3S-0PL-PD No A at 75 to 6 VAC (See note.) G3S-A 5 VDC No 0.6 A at 75 to 6 VAC (See note.) G3S-A 5 VDC Yes G3SD-Z0P-PD A at 3 to 6 VDC (See note.) G3S-D 5 VDC No 0.6 A at 3 to 6 VDC (See note.) G3S-D 5 VDC Note:. Electromagnetic relay-equipped G6B-@@ND models are also available. Refer information on G6B-@@ND (page ).. Given as "50 VAC" on the G3S. 3. Given as "" on the G3S. Accessories (Order Separately) Connection Sockets (Can be Purchased Individually) P6BF-BND Rated voltage 5 VDC Heat Sinks (Can be Purchased Individually) Y9B-S0 Replacement Relays G3S-0PL-PD G3SD-Z0P-PD Rated voltage 5 VDC 5 VDC Relay Removal Tool, Short Bar and Terminal Cover (Order Separately) Refer to Options for the G6B-CB, G6B-@@ND, and G3S on page. Relay Mounting Products (Order Separately) Refer to Common Sockets/Products Related DIN Tracks. 8

Specifications G3S Ratings Input (per G3S Relay) Rated voltage Operating voltage Note: The rated current includes the terminal's LED current. Output (per G3S Relay) Characteristics Must operate level Must release voltage level G3S-A, G3S-A Input impedance G3S-D, G3S-D G3S-A, G3S-A Rated current G3S-D, G3S-D DC 5 V to 6 VDC VDC max. VDC min. 0 Ω±0% 550 Ω±0% 9. ma±0% 5.8 ma±0% V 9.6 to. VDC 9.6 VDC max. kω±0%. kω±0% 5.8 ma±0%.5 ma±0% V 9. to 8.8 VDC 9. VDC max.. kω±0%.3 kω±0% 5.7 ma±0% 3. ma±0% Applicable load Load voltage Load current Inrush current resistance G3S-A 75 to 6 VAC 0. to A 5 A (60 Hz, cycle) G3S-A 0. to 0.6 A G3S-D 3 to 6 VDC 0.0 to A 3 A (0 ms) G3S-D 0.0 to 0.6 A Item G3S-A, G3S-A G3S-D, G3S-D Must operate time ms max. Release time 0.5 load power cycle ms max. ms max. Output ON voltage drop.6 V max. (RMS).5 V max. Leakage current ma max. 0. ma max. (at 6 VDC) Insulation resistance Dielectric strength Vibration resistance Shock resistance,000 m/s Storage temperature 00 MΩ min. (at 500 VDC),000 VAC, 50/60 Hz for min 0 to 55 to 0 Hz, 0.75-mm single amplitude (.5-mm double amplitude) 30 to 00 C (with no icing) Ambient operating temperature 30 to 80 C (with no icing) Ambient operating humidity 5% to 85% Weight Approx. 95 g (-A model) Approx. 95 g (-D model) Engineering Data Reference Data (per G3S Relay) Load Current vs. Ambient Rated Temperature Inrush Current Resistance Non-repetitive (Keep the inrush current to half the rated value if inrush current occurs repetitively.) G3S-A, G3S-A G3S-D, G3S-D Load current (A) 0.75 G3S-A, G3S-D G3S-A, G3S-D Inrush current (A. Peak) 5 0 5 0 Inrush current (A. Peak) 3 0 0.6 0.5 0.5 0. 0 30 0 0 0 0 60 80 00 Ambient temperature ( C) 0 30 50 00 00 500,000 5,000 Energizing time (ms) 0 30 50 00 00 500,000 5,000 Energizing time (ms) Note: Measurement values taken from production line samples have been plotted in graphs to provide this data. Use this data only as a guide. Relays are mass-produced, so allowances must be made for a certain amount of variation in measurement data. 9

Dimensions G3S Note: All units are in millimeters unless otherwise indicated. Relays With Heat Sinks 6-M3.5 3 max. G3S-A G3S-D 78 max. Mounting Holes Two, -dia. holes or M3.5 screw holes 3 max. 8 max. 33 max. 65±0.3 Without Heat Sinks 6-M3.5 G3S-A G3S-D 36±0. 78 max. 3 max. 8 max. 33 max. Terminal Arrangement/Internal Connections Input side 8 3 7 6 5 Accessories (Order Separately) Connection Socket (Can be Purchased Individually) P6BF-BND (with operation indicator) 78 max. 6-M3.5 Output side () () 0 () 9 () 6 () 5 () () 3 () Note: Make sure that the polarity of the input terminal is correct. The polarity given inside parentheses ( ) is for G3S-D and G3S-D Relays. There is no indication of polarity when Connection Sockets are used alone. 3 max. 8 max. Heat Sinks (Can be Purchased Individually) Y9B-S0 5 0 0. Mounting Brackets (3.5) 5 (7.5) 0.5 8. 8. 8. 0 0.3 8. 8. 0.5 0.5 0 0.7 0 0 0.3 0 5 36± 8 7 0 0.3 0

G3S Replacement Relays G3S-0PL-PD G3SD-Z0P-PD 6.5 max. 6 max. 0.6 0 max. 0 max. 0.8 0. 7.6 7.6 Input voltage Terminal Arrangement/Connections (Bottom View) () () INPUT LOAD 6 () Load power supply Load () Note:. The polarity given inside parentheses ( ) is for DC loads.. The load can be connected to ether the positive or negative SSR output terminal. Relay Removal Tool and Short Bar (Order Separately) Refer to Options for the G6B-CB, G6B- @@ND, and G3S on page. Relay Mounting Products (Order Separately) Refer to Common Sockets/Products Related DIN Tracks. Safety Precautions Refer to Safety Precautions for All Relays. Precautions for Correct Use The four SSRs are mounted individually. Use standard SSR connection methods. There is almost no differences based on the mounting direction. Mount the Terminal SSR with the best air flow. Apply a silicon grease for heat radiation (e.g., YG660 or G76 from Shin-Etsu Chemical Co. Ltd.) between the heat sink and the SSR if the heat sink is removed during maintenance of the G3S-A or G3S-D Terminal SSR (with external heat sinks) or if an external heat sink that was purchased separately is mounted. The load voltage cannot be increased by connecting the G3S load terminals in serial. This is because there is a small difference in the SSR operating time The load current cannot be increased by connecting the G3S load terminal in parallel. This is because there is a small difference in the SSR operating time. The P6BF-BND Connection Socket has an operation indicator and is available in 5-VDC, -VDC, and -VDC models. Use the P6B-Y Relay Removal Tool to remove SSRs. Mounted Relays Relays and SSRs cannot be mounted together.

Options for the G6B-CB, G6B-@@ND, and G3S Relay Removal Tool P6B-Y Ordering Information Applicable Terminal Relays G6B-CB G6B-@@ND G3S P6B-Y Short Bar G6B--SB A Short Bar is used to wire crossovers for common terminals for coils or contacts. Ordering Information 6.8.5 9.5 6.8 3.6 8.5 8.5 8.5 Applicable Terminal Relays G6B-CB G6B-@@ND G3S G6B--SB (3.3) Terminal Cover (Two per Set) G6B--C Ordering Information Applicable Terminal Relays G6B-BND G6B-7BND G6B-8BND G3S-A G3S-D G6B--C Connection Socket (Can be Purchased Individually) P6BF-BND (with operation indicator) 6-M3.5 Ordering Information Applicable Terminal Relays Rated voltage 78 max. G6B-BND G6B-7BND G3S P6BF-BND 5 VDC Also give the voltage specification. P6BF-BND Connection Sockets do not have specific approved standards. 3 max. 8 max.

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 07. In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 07 All Right Reserved.