Rear Door Heat Exchanger

Similar documents
DATA CENTER LIQUID COOLING

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Energy Efficient Data Centers

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

NetShelter CX Performance Guide

Power and Cooling for Ultra-High Density Racks and Blade Servers

HIGH DENSITY RACK COOLING CHOICES

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

APC InRow Cooler Prototype Initial Report - Test Setup Verification. H. Coles, S. Greenberg Contributing: J. Bean (APC) November 18, 2011

Thermal management. Thermal management

Energy Efficiency and WCT Innovations

NetShelter CX Technical Guide

A LAYMAN S EXPLANATION OF THE ROLE OF IT RACKS IN COOLING YOUR DATA CENTER

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

Green IT and Green DC

Optimizing Cooling Performance Of a Data Center

HP Modular Cooling System: water cooling technology for high-density server installations

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

Thermal Design and Management of Servers

System Overview. Liquid Cooling for Data Centers. Negative Pressure Cooling Without Risk of Leaks

APC APPLICATION NOTE #146

QSFP-DD: Enabling 15 Watt Cooling Solutions

Planning for Liquid Cooling Patrick McGinn Product Manager, Rack DCLC

Close Coupled Cooling for Datacentres

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Rittal Cooling Solutions A. Tropp

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Systems and Technology Group. IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development

Axial Channel Water Jacket Cooling

Dominick Lovicott Enterprise Thermal Engineering. One Dell Way One Dell Way Round Rock, Texas

Water-Cooling and its Impact on Performance and TCO

Rack & Enclosure Systems

ENCLOSURE THERMAL TESTING HEAT REMOVAL IN THE REAL WORLD

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

APC APPLICATION NOTE #74

INNOVATE DESIGN APPLY.

ENCLOSURE HEAT DISSIPATION

INNOVATE DESIGN APPLY.

Effectiveness and Implementation of Modular Containment in Existing Data Centers

Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc.

Liquid Cooling Package LCP Cooling Systems

ECOBAY: Closed loop water cooled server cabinet for data centers

Improving Rack Cooling Performance Using Blanking Panels

Reducing Data Center Cooling Costs through Airflow Containment

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

APC APPLICATION NOTE #114

Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer

Cooling System. Cooling System Overview. 16-Slot Line Card Chassis Airflow

1.866.TRY.GLCC WeRackYourWorld.com

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Switch to Perfection

LCP Hybrid Efficient performance with heat pipe technology

Liebert DCW CATALOGUE

Optimizing the Integration of an Electronics System into an Existing Enclosure Using CFD Modeling Techniques

Power & Cooling Considerations for Virtualized Environments

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

Rittal White Paper 506: Cold Aisle Containment for Improved Data Center Cooling Efficiency By: Daniel Kennedy

Perfect Cooling. A perfect climate for high performance servers

Modbus Register Map: InRow ACRD60x / ACRC60x

Enterprise and Datacenter. SSD Form Factor. 1U Long Specification

A Green Approach. Thermal

Data Center Assessment Helps Keep Critical Equipment Operational. A White Paper from the Experts in Business-Critical Continuity TM

Packaging of New Servers - energy efficiency aspects-

Rethinking Datacenter Cooling

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

PERFORMANCE DATA SCD. SCD 12 in. x 12 in. Face Size. SCD 20 in. x 20 in. Face Size. Square Cone Diffuser

Retro-Commissioning Report

Next Generation Cooling

RACK INFRASTRUCTURE EFFECTS ON THERMAL PERFORMANCE OF A SERVER

Industry leading low energy evaporative fresh air cooling.

Data Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center

Introducing. IBM idataplex. Gilad Berman System x

Liquid Cooling Package LCP Cooling Systems

Customer Power Needs..and how to design for them

How to Increase Data Center Efficiency

Virtualization and consolidation

HPC/Advanced Cooling Track. Rolf Brink/CEO/Asperitas

BENEFITS OF ASETEK LIQUID COOLING FOR DATA CENTERS

High Density Cooling Solutions that work from Knurr Kris Holla

Data Center Energy Savings By the numbers

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

QuickSpecs. HP Modular Cooling System. Overview

Scalable, Secure. Jason Rylands

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

CFD Modeling of an Existing Raised-Floor Data Center

Liebert XD Flexible, Energy-Saving Cooling Solutions For High Heat Density Applications. Precision Cooling For Business-Critical Continuity

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Improving Ducting to Increase Cooling Performance of High-End. Web Servers Subjected to Significant Thermal Shadowing

Energy Efficiency and Water-Cool-Technology Innovations

Review on Performance Metrics for Energy Efficiency in Data Center: The Role of Thermal Management

Closed-Loop Water-Cooled Enclosure GL840ES-3048-CLWCE. High Performance 30kW Closed-Loop Water-Cooled Enclosure COOL THE SERVERS, NOT THE ROOM!

Transcription:

Vinod Kamath Power and Thermal Engineering Sep 16, 2005

Problem Statement Rack Power loads are high due to increased compute density. The impact is seen in datacenters as high inlet air temperatures to the equipment. Datacenter flow balancing issues can create local hotspots as well. The consequence can be lowered system reliability and failures. High fan and blower speeds can be seen due to higher inlet temperatures. Added acoustics signatures of equipment can create user discomfort. Exit air temperatures from servers can be 50 deg C or higher "Maintaining Datacom Rack Inlet Air Temperatures with Water Cooled Heat Exchanger" - Schmidt et al., Proceedings IPACK2005.

Solution Characteristics Localized spot treatment required Heat exchange with exit air provides the most efficient mechanism for temperature reduction A low airflow pressure drop solution can provide a "passive mechanism" for heat extraction Small footprint impact on existing datacenters of design.

Solution Details Replace an existing Rear Door with a heat exchanger The footprint increase is about 5.6" on the rack Uses existing hinge and latch assemblies with > 90 deg C open capacity Water delivered using 3/4" ID supply and return hoses Industry standard quick connect hydraulic couplings to door

Salient Features The heatexchanger is a tube-and-fin design with low air side pressure drop Operates using above dew point water Robust quality control in the braze process and build process Door design enables high strength-weight ratio (70 lb.) Protective barriers to fins Handles for Install

Rear Door Heat Exchanger

Standalone Performance Rack Level Testing with high power density servers Bladecenters were used in the rack Functional 1U servers were used as well to determine heat extraction The tests were conducted in a room where the inlet temperature could be maintained between 23-25 deg C. The water flow rate was maintained at 7 GPM in the test cases and the water inlet temperature was kept at 17 deg C

Test Results Rear Door Heat Exchanger The results for the BladeCenter and 1U rack servers show between a 50% to 60% heat extraction of the input heat load. The increase in airflow impedance to the servers can result in a marginal 1 deg C impact to the CPU temperatures due to a slight flow loss to the servers The exit air temperature from the RDHX is reduced by an average of 25 deg C from the discharge end of the servers.

Blade Center Tests Thermal Load Blade (250W-450W)

Blade Center Tests Rear Door Heat Exchanger 6 BladeCenter Chassis 5 Thermal Equivalent Chassis, 1 Functional Chassis Thermal Blade with Calibrated impedance and power Each Unit Calibrated to determine airflow and power Functional tests run at different airflow rates and power loads Data at 1530 CFM (approach flow) Water Flow at 7 GPM Rack Power (kw) Air Inlet to Rack (C) Water Inlet(C) Water Outlet(C) Heat Extraction (kw) Efficiency (% age) 16.3 26.8 17.3 23.4 12.02 49.9 31.5 24.5 17.1 26.9 18.12 49.9

1U Tests 40 - x336 1U with Xeon 2.8 GHz CPUs 5 GPM Water at 17 deg C Measured Power 10.6 kw for Rack Rack Power (kw) Air Inlet to Rack (C) Water Inlet(C) Water Outlet(C) Heat Extraction (kw) Efficiency (% age) 10.6 24.5 18.3 22.8 5.94 56.0