Mediant 1000B Chassis. Physical Description

Similar documents
Configuration Note Restoring Factory Defaults

Configuration Note How to Backup and Restore SPS

Technical Application Note

Configuration Note. MP-26x Debugging and Diagnostic Tools. MP-26x Series. Version and Later. AudioCodes CPE & Access Gateway Products

Configuration Note Recover from Rescue Mode Procedure

Configuration Note 3G Cellular Modem WAN Connection

Configuration Note. Connecting MSBR to WAN through 3G Cellular Modem. Multi-Service Business Router (MSBR) Mediant 850 MSBR.

Configuration Note Recovery from Rescue Mode Procedure

400HD Series of High Definition IP Phones. Configuration Note. Call Recording on AudioCodes. 400HD Series IP Phones. Document #: LTRT-11360

Installation Guide. Version 1.0. AudioCodes Applications License Server. December 2014 Document # LTRT-00876

Configuration Note How to Install SPS on the SBA

Administrator and User Manual Hot Desking with SPS for Microsoft Lync

Configuration Note. RADIUS for Secure Device Access. Multi-Service Business Routers. Enterprise Session Border Controllers. VoIP Media Gateways

MP-11x, Mediant 1000 & Mediant Application Note

Configuration Note. SPS Best Practice Preventative Maintenance and Health Check Procedures. Version 1.0. SIP Phone Support (SPS) VoIP Media Gateways

User's Guide. AudioCodes CLI Wizard Utility. Session Border Controllers (SBC) Multi-Service Business Routers (MSBR)

Mediant Software E-SBC. Session Border Controllers. Virtual Edition. Installation Manual. Version 6.6. October 2013 Document #: LTRT-10343

SBC Deployment Guide Architecture Options and Configuration Examples

Hardware Installation Manual

User's Guide Call Progress Tones Wizard (CPTWizard) Utility

Configuration Guide IP-to-IP Application

Hardware Installation Manual

SBC Configuration Examples

SIP Phone Support. Release Notes. Version

Configuration File Backup and Restore Procedure

CloudBond 365 Pro / Enterprise Box Editions

Transport Layer Security (TLS) Configuration Note

Quick Start Guide. AudioCodes One Voice for Microsoft Skype for Business. CloudBond 365. Pro / Enterprise Box Edition. Version 7.0

Solution SPSS. Compatible. From Ver For. ays

CloudBond 365 Standard / Standard+ Box Editions

Configuration Note. Connecting XO Communications SIP Trunking Service to Microsoft Lync Server Using

Hardware Installation Manual

Configuration Note Debug Recording Feature

Performance Monitoring and Alarm Guide

Backup and Restore Procedure

IP Phone Manager Express

Microsoft Office 365 X-UM with IP PBXs using AudioCodes CloudBond X-UM Standard

AudioCodes CPE & Access Gateway Products MP-20x Multimedia Home Gateway Quick Guide MediaPack 20x for BroadSoft s BroadCloud PacketSmart Monitoring

IP Phone Manager Express

MediaPack TM Series. MP-11x & MP-124. Analog VoIP Gateways. Installation Manual. Version 6.6. April 2012 Document #: LTRT-59815

Configuration Note Capturing Traffic on MSBR

Mediant 1000B Survivable Branch Appliance (SBA) for Microsoft Skype for Business

SBA Management Interface for Skype for Business

SBC Configuration Examples for Mediant SBC

Mediant Appliances. Mediant 800 CCE & Mediant Server CCE. Microsoft Skype for Business Cloud Connector Edition (CCE) Version

Mediant 800 Gateway and E-SBC

Configuration Note. Enhanced Gateway with Analog Devices for Microsoft Lync Server Microsoft Lync Server 2010.

Hardware Installation Manual. Mediant Media Gateway & Enterprise Session Border Controller (E-SBC) Version 7.0

Mediant Server Cloud Connector Edition

Mediant CCE Appliances

SmartTAP Call Recording Solution

Release Notes. AudioCodes One Voice for Microsoft Skype for Business. Mediant SBA for Microsoft Skype for. Business. Version 7.2

Performance Monitoring and Alarm Guide

CPE & Digital Access Gateways. MediaPack MP-40x. User s Manual. Version 2.2

Mediant Cloud Edition (CE)

Mediant VE SBC. Session Border Controller. Virtual Edition. Installation Manual. Version 6.8. June 2015 Document #: LTRT-10352

Installation & Maintenance Manual. Mediant 2600B. Survivable Branch Availability (SBA) for Microsoft Skype for Business. Version 7.

Configuration Note Microsoft Lync Server 2013 & tipicall SIP Trunk using Mediant E-SBC

User Management Pack 365

Configuring MediaPack 1288 Analog Gateway as Third-Party SIP Device (Advanced) in Cisco Unified Communications Manager Ver

AUDIOCODES DESIGN GUIDE BUSINESS CONNECTIVITY SOLUTIONS

Mediant MSBR. Wireless Access Configuration. Configuration Guide. Version 6.8. Multi-Service Business Routers Product Series

CloudBond 365 & User Management Pack 365

VOCANOM Web Based Management Tool Administrator's Guide

AudioCodes Academy Course Catalog February 2013

Configuration Note Microsoft Lync Server 2013 & BluIP SIP Trunk using Mediant E-SBC

NVR-CV. Network Video Recorder Hot-Swappable Tray for 3.5 HDD x 4 or 2.5 HDD x 4 Gigabit Ethernet x 2 COM x 2, USB2.0 x 6. VGA x 1, DVI-D x 1

MIL-STD Rugged Computer User's Manual. Version 1.0 Revision Date: July. 05, 2017 THOR200. MIL-STD Rugged Computer

Configuration Note. Microsoft Lync Server 2013 & ITSP SIP Trunk using AudioCodes Mediant SBC. Interoperability Laboratory. Version 6.

Installation Manual. Version 6.0

Hardware Installation Manual. AudioCodes Mediant Family of Session Border Controllers. Mediant 500. Enterprise Session Border Controller (E-SBC)

MediaPack 1xx Analog VoIP Gateway

Configuration Note. AireSpring SIP Trunk & Genesys Contact Center using AudioCodes Mediant SBC. Session Border Controllers (SBC)

Administrator's Manual

SEM for AudioCodes Media Gateways and Servers. Session Experience Manager. User's Manual. Version 6.8

RS-232 Connector Pin Assignments

Mediant 500L. Enterprise Session Border Controller (E-SBC) and Media Gateway. Hardware Installation Manual

SIP Phone Support (SPS)

User's Guide. AudioCodes One Voice Operations Center. SBA ProConnect. Version 7.2

DA-820 Series Quick Installation Guide

Introducing the Cisco NAM 2220 Appliance

FWA-6280A User Manual 1. FWA-6280A User Manual

MP-11x Fast Track Installation Guide MGCP, H.323 & SIP. Version 4.6 Document #: LTRT-61504

Installation Manual. Table of Contents

AudioCodes Element Management System (EMS) and Session Experience Manager (SEM) Release Notes. Version 6.8

Installation Manual. Version 5.8

PCIE-Q57A Quick Installation Guide

LifeSize Multipoint 230 Installation Guide

Hardware Installation Manual

400HD Series of High Definition IP Phones. User s Manual. 420HD IP Phone with Microsoft Lync. Version 2.0.1

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Configuration Note Microsoft Lync Server 2013 & Netia SIP Trunk using Mediant E-SBC

User's Manual. Version 5.8

AudioCodes Routing Manager (ARM)

Installation, Operation and Maintenance Manual

Configuration Note. Microsoft Lync Server 2013 & NextGenTel SIP Trunk using Mediant E-SBC. Enterprise Session Border Controllers (E-SBC)

EPC-APL. Quick Reference Guide. Intel Pentium /Celeron Processor Fanless Tiny System. Copyright Notice. 1 st Ed 12 September 2017

OnRISC. OnRISC Baltos ir 2110

DNS-2608 Enterprise JBOD Enclosure User Manual

Hardware Installation Manual

Transcription:

Mediant 1000B Chassis Physical Description Document #: LTRT-1401 November 2009

Physical Description Contents Table of Contents 1 Introduction... 7 2 Chassis Description... 9 2.1 Front-Panel Description... 9 2.2 Rear-Panel Description... 10 3 OSN3 Platform... 11 3.1 OSN3 Module... 12 3.1.1 Ports Description... 12 3.1.2 LEDs Description... 14 3.2 HDMX (Hard-Disk Drive) Module... 16 3.3 Inserting and Extracting AMC Modules... 17 3.3.1 Inserting a Module... 17 3.3.2 Extracting a Module... 18 Version 5.8 3 November 2009

Mediant 1000B Chassis List of Figures Figure 2-1: Front-Panel Components... 9 Figure 2-2: Rear-Panel Components... 10 Figure 3-1: OSN3 Module Ports... 12 Figure 3-2: OSN3 LEDs... 14 Figure 3-3: HDMX Module Components... 16 Figure 3-4: Extracting AMC Modules... 18 List of Tables Table 2-1: Front-Panel Component Description... 9 Table 2-2: Rear-Panel Component Descriptions... 10 Table 3-1: OSN3 Specifications... 11 Table 3-2: OSN3 Module Component Description... 12 Table 3-3: Gigabit Ethernet Interface (RJ-45) Connector Pinouts... 13 Table 3-4: RS-232 Serial Interface (RJ-45) Connector Pinouts... 13 Table 3-5: OSN3 Module LED Description... 14 Table 3-6: HDMX Module LED Description... 16 Physical Description 4 Document #: LTRT-1401

Physical Description Notices Notice This document provides an overview of AudioCodes Mediant 1000-B chassis. Information contained in this document is believed to be accurate and reliable at the time of printing. However, due to ongoing product improvements and revisions, AudioCodes cannot guarantee accuracy of printed material after the Date Published nor can it accept responsibility for errors or omissions. Updates to this document and other documents can be viewed by registered customers at http://www.audiocodes.com/downloads. Copyright 2009 AudioCodes Ltd. All rights reserved. This document is subject to change without notice. Date Published: November-05-2009 Tip: When viewing this manual on CD, Web site or on any other electronic copy, all cross-references are hyperlinked. Click on the page or section numbers (shown in blue) to reach the individual cross-referenced item directly. To return back to the point from where you accessed the cross-reference, press the ALT and keys Trademarks AudioCodes, AC, AudioCoded, Ardito, CTI2, CTI², CTI Squared, HD VoIP, InTouch, IPmedia, Mediant, MediaPack, NetCoder, Netrake, Nuera, Open Solutions Network, OSN, Stretto, TrunkPack, VoicePacketizer, VoIPerfect, VoIPerfectHD, What s Inside Matters, Your Gateway To VoIP and 3GX are trademarks or registered trademarks of AudioCodes Limited. All other products or trademarks are property of their respective owners. WEEE EU Directive Pursuant to the WEEE EU Directive, electronic and electrical waste must not be disposed of with unsorted waste. Please contact your local recycling authority for disposal of this product. Customer Support Customer technical support and service are provided by AudioCodes Distributors, Partners, and Resellers from whom the product was purchased. For Customer support for products purchased directly from AudioCodes, contact support@audiocodes.com. Version 5.8 5 November 2009

Mediant 1000B Chassis Abbreviations and Terminology Each abbreviation, unless widely used, is spelled out in full when first used. Only industrystandard terms are used throughout this manual. Hexadecimal notation is indicated by 0x preceding the number. Related Documentation Document # LTRT-52304 LTRT-83505 LTRT-83305 Manual Name Product Reference Manual for SIP Gateways and Media Servers Mediant 1000 SIP-MEGACO Installation Manual Mediant 1000 & Mediant 600 SIP User's Manual Physical Description 6 Document #: LTRT-1401

Physical Description 1. Introduction 1 Introduction The new Mediant 1000B chassis, based on the incumbent Mediant 1000 chassis is designed to support the Advanced Mezzanine Card (AMC) or AdvancedMC form-factor modules. It provides eight AMC slots (for housing single and mid-sized AMC modules) on its rear panel. The Mediant 1000B supports both VoIP Gateway and MSBG data routing functionalities, by hosting either the CMX or CRMX module, respectively. The Mediant 1000B also provides support for the regular Mediant 1000 telephony modules (i.e., FXS, FXO, and digital PSTN). The Mediant 1000B chassis supports (optional) the latest OSN server platform - OSN3. The OSN3 provides AMC-based modules, offering high performance CPUs targeted for applications requiring high performance processors. The OSN3 can also be provided with dual SATA hard-disk drives (HDD). Any usage of additional AMC modules that are not described or mentioned in this document, will need to be approved by AudioCodes. Note: For a detailed description on installing the Mediant 1000B, refer to the Mediant 1000 SIP-MEGACO Installation Manual. Version 5.8 7 November 2009

Mediant 1000B Chassis Reader s Notes Physical Description 8 Document #: LTRT-1401

Physical Description 2. Chassis Description 2 Chassis Description This section describes the Mediant 1000B chassis front (refer to Section 2.1) and rear (refer to and Section 2.2 on page 10) panels. 2.1 Front-Panel Description The Mediant 1000B chassis front panel is displayed in the figure below and described in Table 2-1. Figure 2-1: Front-Panel Components Table 2-1: Front-Panel Component Description Item # Label Description 1 FXS, FXO, TRUNKS, BRI, MPM Telephony modules. 2 CRMX or CMX Hosts either the CRMX module (for data routing) or the CMX module (CPU for VoIP gateway functionality) 3 Power 1 (Optional) Spare Power Supply module slot 4 Power 2 Main Power Supply module 5 - Extractable Fan Tray module with a schematic displayed showing the chassis' slot numbers Version 5.8 9 November 2009

Mediant 1000B Chassis 2.2 Rear-Panel Description The Mediant 1000B chassis front panel is displayed in the figure below and described in Table 2-2. Figure 2-2: Rear-Panel Components Table 2-2: Rear-Panel Component Descriptions Item # Label Description 1 Protective earthing screw. 2 ESD Electrostatic Discharge (ESD) socket. 3 100-240V~1A Dual AC Power Supply Entries. 4 OSN3 OSN3 AMC module. 5 HDD Main Hard-disk drive (HDD) AMC module for OSN3 platform. 6 HDD Second, optional HDD for OSN3 platform. 7 - Empty AMC module slots. Physical Description 10 Document #: LTRT-1401

Physical Description 3. OSN3 Platform 3 OSN3 Platform The Mediant 1000B chassis supports an optional OSN server platform - OSN3. The table below lists the specifications of this OSN3 server platform: Table 3-1: OSN3 Specifications Parameter CPU RAM Memory Storage Bus/Chipset L2 Cache Specification Intel Core 2 Duo 1.5 GHz processors L7400 with Intel 3100 Chipset (64-bit) 2 G or 4 G DDR2 with ECC Single or Dual hard-disk drive of 80 G SATA 64 Bit 2 M Interfaces Gigabit Ethernet USB 2.0 via Connection Module RS-232 COM The OSN3 platform consists of two main AMC modules: OSN3, providing the port connector interfaces (refer to Section 3.1 on page 12) HDMX, providing the hard-disk drive (refer to Section 3.2 on page 16) These AMC modules can easily be inserted and extracted, as described in Section 3.3 on page 17. Version 5.8 11 November 2009

Mediant 1000B Chassis 3.1 OSN3 Module The OSN3 module s ports (refer to Section 3.1.1 below) and LEDs (refer to Section 3.1.2 on page 14) are described in this section. 3.1.1 Ports Description The OSN3 module connector ports are shown in the figure below and described in Table 3-2. Figure 3-1: OSN3 Module Ports Table 3-2: OSN3 Module Component Description Item # Label Description 1 RJ-45 port for RS-232 serial interface (COM1) 2 RJ-45 port for Gigabit Ethernet. The interface provides automatic detection and switching between 10Base-T, 100Base-TX and 1000Base-T data transmission (Auto-Negotiation). Auto-wire switching for crossed cables is also supported (Auto-MDI/X). 3 USB 2.0 port 4 - Insertion/extraction handle Physical Description 12 Document #: LTRT-1401

Physical Description 3. OSN3 Platform The RJ-45 connector pinouts for Gigabit Ethernet interface are listed in the table below: Table 3-3: Gigabit Ethernet Interface (RJ-45) Connector Pinouts Pin 100Base-Tx 1000Base-T I/O Signal Signal Function 1 O Tx+ I/O BI_DA+ 2 0 Tx- I/O BI_DA- 3 I Rx+ I/O BI_DB+ 4 I/O BI_DC+ 5 I/O BI_DC- 6 I Rx- I/O BI_DB- 7 I/O BI_DD+ 8 I/O BI_DD- The RJ-45 connector pinouts for RS-232 interface are listed in the table below: Table 3-4: RS-232 Serial Interface (RJ-45) Connector Pinouts Pin Signal Function 1 RTS Request to send 2 DTR Data terminal ready 3 TXD Transmit data 4 GND Signal ground 5 GND Signal ground 6 RXD Receive data 7 DSR Data send ready 8 CTS Clear to send Version 5.8 13 November 2009

Mediant 1000B Chassis 3.1.2 LEDs Description The OSN3 LEDs are shown in the figure below and described Table 3-5. Figure 3-2: OSN3 LEDs Table 3-5: OSN3 Module LED Description Item # Label Color State Description 1 Red On Damaged hardware - Off Normal operation 2 3 Red On When lit during boot-up, indicates power failure. Flashing - Off Normal operation. Processor over-temperature above 125 C and processor over-temperature above 100 C. 3 2 Red On When lit during boot-up, indicates clock failure. Flashing - Off Normal operation. Processor over-temperature above 125 C and chipset over-temperature above 105 C. 4 1 Red On When lit during boot-up, indicates a hardware reset. Flashing - Off Normal operation. Processor over-temperature above 125 C. 5 0 Red On When lit up during boot-up, indicates a BIOS boot failure. Flashing - Off Normal operation. Processor over-temperature above 125 C. Physical Description 14 Document #: LTRT-1401

Physical Description 3. OSN3 Platform Item # Label Color State Description 6 Blue Flashing Module undergoing shutdown sequence when module pulled out to first extraction position. 7 Red On Out of Service On Off Flashing Module shutdown sequence complete and the module can be extracted from the chassis slot. Module correctly inserted in chassis slot Upgrade - Off Normal operation 8 SPEED Green On 100Base-TX connection. Yellow On 1000Base-T connection - Off 10Base-T connection if ACT LED active. 9 ACT Green On Valid Ethernet link (cable connection) has been established. - Off The LED goes temporarily off if network packets are being sent or received through the RJ-45 port. When this LED remains off, a valid link has not been established due to a missing or a faulty cable connection. Version 5.8 15 November 2009

Mediant 1000B Chassis 3.2 HDMX (Hard-Disk Drive) Module The components of the HDMX module is shown in the figure below and described in Table 3-5. Figure 3-3: HDMX Module Components Table 3-6: HDMX Module LED Description Item # Label Color State Description 1 Green On Power received by HDD. - Off No power received by HDD. 2 Blue Flashing Module undergoing shutdown sequence when module pulled out to first extraction position. On Off Module shutdown sequence complete and the module can be extracted from the chassis slot. Module correctly inserted in chassis slot 1 Red Flashing The OSN server's hard disk drive (HDD) is in use (active). - Off Hard disk drive not in use. Physical Description 16 Document #: LTRT-1401

Physical Description 3. OSN3 Platform 3.3 Inserting and Extracting AMC Modules The OSN3 modules are designed for hot-swappable operation. Hot swapping allows the coordinated insertion and extraction of modules without disrupting other operational elements within the system. This allows for identified faulty elements to be removed and replaced without taking the entire device out of service. In addition, the AMC module s insertion-extraction handle allows for quick-and-easy replacement of faulty modules. 3.3.1 Inserting a Module The following procedure describes how to insert an AMC module into the chassis slot. To insert the module: 1. Carefully insert the module into the slot until it makes contact with the AMC card-edge connector located on the backplane. 2. Connect all external interfacing cables to the module as required. 3. Using the handle on the front panel, engage the module with the chassis backplane. 4. When the handle is locked, the module is engaged; the HS LED turns off. Version 5.8 17 November 2009

Mediant 1000B Chassis 3.3.2 Extracting a Module The following procedure describes how to extract an AMC module from the chassis. Note: Before extracting the HDMX module (if required), you must perform a harddisk drive dismount (i.e., a logical disconnection of the hard drive). To extract the module: 1. Pull the handle on the module s front panel and semi extract the module to the first click ; the module performs a shutdown sequence indicated by the flashing blue Hot Swap LED (see stages 1 and 2 in the figure below). 2. When the LED stops flashing and remains constantly on, disconnect any interfacing cables that may be connected to the module. 3. Using the module s handle, pull the module out of the slot (see stage 3 in the figure below). Figure 3-4: Extracting AMC Modules Physical Description 18 Document #: LTRT-1401

Physical Description 3. OSN3 Platform Reader s Notes Version 5.8 19 November 2009

Mediant 1000B Chassis Physical Description www.audiocodes.com