SDY. PC-Programmable Signal Isolator/Converter with Display

Similar documents
SIY. New. Features! Features. PC-Programmable Signal Isolator/Converter

SIY. Features. PC-Programmable Signal Isolator/Converter

SFY Functional Safety Frequency-to-DC Transmitter with Display

FDY. Features Exceptional accuracy and long-term stability. Typical accuracy is ±0.025% of span with up to 5 years between scheduled calibrations.

HIT/HIX HART Isolator

ECT Signal Isolator/Converter

TCS. Description. Features. IECEx. Temperature Concentrator System Multi-Channel Transmitter

STA SIL 2 and SIL 3 Capable Programmable Current/Voltage and RTD/Thermocouple Safety Trip Alarms

HTZ. Description. Features. Smart HART Humidity and Temperature Transmitter

SYI TDY. User s Manual. PC-Programmable Temperature Transmitter with Display. Demand Moore Reliability. No H November 2017

Intrinsically Safe Barriers

NOW A PRODUCT! 1/4 DIN Auto/Manual Station. The Interface Solution Experts. The Interface Solution Experts. PS532 V6 March 2017

TIY TIY. Thermocouple Transmitter. Programmable Isolated. Programmable Isolated Thermocouple Transmitter. July E

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

General Specifications

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010

General Specifications

PD301 - PD306 Head Mount SMART TEMPERATURE TRANSMITTERS

B April Functional Safety Programmable Loop Display SLD.

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

FLEX Ex Spring Clamp Terminal Base

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

SYI TRY & TRX TRX & TRY. User s Manual. PC-Programmable Temperature Transmitters. Isolated (TRY) & Non-Isolated (TRX)

General Specifications

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

HES. Description. Industrial Internet of Things - HART Over Ethernet

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Analyze IT Analytical Instruments Two-Wire ph, ORP, plon Transmitters

3420 Fieldbus Interface Module (FIM) Contents

TS Series. Description

General Specifications

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

General Specifications

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

SCADAPack Modbus multivariable transmitter

Analytical Instruments Two-Wire ph, ORP, plon Transmitters

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

SITOP in the SIMATIC Design

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Process Current Input with Loop Power 7B35

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

PHOENIX CONTACT - 12/2007

MODEL 9250 Preliminary data sheet

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-24VDC

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

INSTRUCTION MANUAL MODEL RTI-EC RESISTANCE TEMPERATURE INDICATOR TABLE OF CONTENTS 1. GENERAL DESCRIPTION PAGE 1

Redundancy Module QUINT-DIODE/40

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

DTM Distributed Transmitter Monitor

Trendmaster* Galvanic Isolator

Process display RIA 251. Digital loop powered display for ma current loops. Application areas. Plant and machine construction.

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

TEPI11 P/I signal converter

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

User's Manual: Series 250T Potentiometer/Slidewire Input, Two-Wire Transmitters

Trident and Trident X2 Digital Process and Temperature Panel Meter

DINALOG A 144 x 36 A1400 Light-Strip Indicator

Isolated Current Output 5B39 FEATURES APPLICATIONS PRODUCT OVERVIEW

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

NCS MIM. with MODBUS Interface. NET Concentrator System. September A. with MODBUS Interface

Thermocouple Input Module Product Specifications and Installation Data

Operating Instructions

MINI MCR-SL-PT100-UI-200

Type i2p-100 Electro-Pneumatic Transducer

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

microncs Description Features MODBUS RTU Master and Distributed I/O System

No J September PC-Programmable Signal Isolator/Converter SIY

M-series Intrinsically Safe I/O

Remote Level Display with Explosion Proof Enclosure

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

5 Fieldbus Technology

TRANSMISSOR DE PRESSÃO PIEZO RESISTIVO INTELIGENTE MICRO PROGRAMÁVEL SÉRIE PAS

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

Thermo Scientific CM515 and HME900 Density Converter Electronics

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

Operating Instructions

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

DeltaV Bulk Power Supplies

TPE 1464 Series Pressure Transducer

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

PD765 TRIDENT. Trident Series Process & Temperature Meters.

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

HART Communicator. Emerson Process Management Catalog

HIGH-VOLTAGE DC METER

itemp TMT180 Technical information

Transcription:

June 2006 Data Sheet 2.45 Description Moore Industries Signal Isolator/Converter with Display combines smart digital technology with a large display to deliver an accurate signal that is easily monitored in the field. The highly versatile accepts a wide range of current or voltage inputs, then outputs the signal as an isolated, proportional, current. A flexible analog/digital hybrid, this 2-wire (looppowered) transmitter programs in seconds to handle a wide range of signal interface applications: Monitor Signals using its large, accurate display. Isolate Signals to stop erratic process measurements caused by ground loops. Convert Signals so field instruments can interface directly with an indicator, recorder, DCS, PLC or PC-based SCADA system. Divert Signals so the output from one transmitter can be sent to two separate locations. Protect Equipment and Signals by eliminating common electrical paths. Boost Signals so that more instruments can be added to an overburdened loop. Solve Bucking Power Supplies by stopping the conflict caused when a 4-wire transmitter and a DCS both power the same process loop. Figure 1. Program the versatile to accept any one of a wide range of inputs and convert the input into the EGU of your choice. M A PS -PS 1 2 3 4 Isolated, Scaleable, Output Large, Easy-to Read Display Available in explosion-proof enclosures and a variety of other configurations, the installs easily in even the most rugged environments. Features Wide range of signal input choices. There s no need to specify and stock fixed-range instruments as spares. The handles the majority of current/voltage interface applications you are likely to encounter. Custom linearization curves. Easily create your own custom linearization curve tables to accurately convert any non-linear input signals to their linear representations. Easy-to-read, customizable display. The s display features two rows of large characters that can be set to display any EGU. Input/output. The delivers superior protection against the harmful effects of ground loops and other plant noise. RFI/EMI protection. The is resistant to the harmful, unpredictable effects of radio frequency and electromagnetic interference. Enhanced configuration software. From a single screen, you can set all the applicationspecific parameters. VOLTAGE 0-1Vdc 0-5Vdc 1-5Vdc 0-10Vdc Special Ranges CURRENT 0-20mA 0-50mA 10-50mA Special Ranges I n p u t Certifications 2006 Moore Industries-International, Inc. 235-710-10B All product names are registered trademarks of their respective companies. Page 1

Specifications Performance Overall Accuracy: ±0.036% of span (includes input accuracy, output accuracy, and the combined effects of linearity, hysteresis, repeatability and adjustment resolution) Stability: Input to output stability (% of span): 1 year: 0.09%; 3 years: 0.15%; 5 years: 0.20% Minimum Input Span: Current, 1.0mA; Voltage, 250mV Isolation: 500Vac/1000Vdc input to output to case Measurement Cycle: Updates 8 times per second Response Time: 128msec from time input is applied until output settles to the specified output accuracy Step Response: 128msec maximum for the output to change from 10% to 90% of its scale for an input step change of 0% to 100% Input Impedance: Voltage, 1Mohms; Current, 20 ohms Load Effect: Negligible within specified load limits Performance (continued) Display Ripple: 10mVpp, maximum (measured across 250 ohm resistor) Power Supply Effect: 0.002% of span per 1V change Over-Voltage Protection: 48V, maximum on output; 48V reverse polarity protection on output Maximum Input Overrange: Current: 100mA maximum continuous; Voltage on Current Input: ±1.5Vdc peak; Voltage: 18Vdc Load Capability: Supply Voltage 10V = Ohms 0.024A Output Current Limiting: 3.8mA (low) and 21.4mA (high) Type: LCD: Top Row, 10.16mm (0.4 in) high black digits on a reflective background; Bottom Row, 5.72mm (0.225 in) high black digits on a reflective background Format: Two rows of five alphanumeric characters Range: -99999 to 99999 Minimum Display Span: 1.00 Ambient Conditions Weight Operating Range: Transmitter: 40 C to 85 C (40 F to 185 F) Display: 25 C to 85 C (13 F to 185 F) Storage Range: 40 C to 85 C (40 F to 185 F) Effect of Ambient Temperature on Accuracy: ±0.015% of span/ C Relative Humidity: 0-95%, non-condensing RFI/EMI Immunity: 20V/m@20-1000MHz, when tested according to SA standard 33.1 abc; 20V/m@20-100MHz, 1kHz AM@80% when tested according to IEC 1000-4-3-1995 with <0.5% error Common Mode Rejection: 100dB, minimum,@50/60hz Normal Mode Rejection: 60dB, typical,@1vp-p, 50/60Hz HP Housing: 178g (6.3 oz) BH Housing: 1.5kg (3.3 lbs) D-BOX Housing: 688g (1 lb, 8.3 oz) Rugged Enclosures Available We carry a complete line of durable enclosures to protect and complement our high-quality isolators. Choose from our explosion-proof BH housing or our NE 4X and IP66 certified D-BOX housing. Everything You Need is Included... Each order comes with one copy of our Intelligent PC Configuration Software (Windows compatible) and one non-isolated configuration cable. To order additional software or cables: Part Number Part 750-75E05-01 Intelligent PC Configuration Software 803-039-26 Isolated Configuration Cable 803-040-26 Non-Isolated Configuration Cable Page 2

Ordering Information Unit Input Output Power Options Housings Isolator/ Converter with Display PRG Programmable with supplied Configuration Software CURRENT (into 20 ohms) Any range from 2.5mA to 55mA including: 0-20mA 0-50mA 10-50mA VOLTAGE (into 1Mohm) Any range from 0.5V to 11V including: 0-1Vdc 0-5Vdc 1-5Vdc 0-10Vdc (recommended minimum span, 250mV) 4-20 User scaleable with supplied software 10-42DC 10-30DC for -ISC, -ISF, -ISE and -NE options To order, specify: Unit / Input / Output / Power [Housing] Model Number Example: / PRG / 4-20 / 10-42DC [BH2NG] -ISC CSA approved IS -ISF FM approved IS -ISE ATEX IS approved -NE ATEX Type N approved with BH BH2NG 2-Hub, explosion-proof enclosure with glass cover BH3NG 3-Hub, explosion-proof enclosure with glass cover D1LC 1-Hub, low base, clear cover, NE 4X (IP66) enclosure D2LC 2-Hub, low base, clear cover, NE 4X (IP66) enclosure HP Hockey-puck housing and spring clips DN Snap-in mounting for HP case on TS-32 DIN rail FL Mounting flanges on HP suitable for relay track or screw mounting FLD Mounting flanges on HP suitable for 3½ relay track or screw mounting SB2NG 2-Hub, Explosion-Proof enclosure with two, ½-inch NPT entry ports and a glass cover SB2MG 2-Hub, Explosion-Proof enclosure with two, M20 x 1.5 entry ports and a glass cover A suffix indicates SAA/TestSafe (Ex d) Flame-Proof approvals (i.e. BH2NGA) E suffix indicates ATEX (EEx d) Flame-Proof approvals (i.e. BH2NGE) P suffix indicates enclosure comes equipped with base plate and U-bolts for mounting on a 2-inch pipe (i.e. BH2NGP or SB2MGP) Certifications Factory Mutual Approvals FM Global [HP in BH and SB Housings] Explosion-Proof* Class I, Division 1, Groups A*, B, C, D. Dust-Ignition Proof Class II & III, Division 1, Groups E, F, G. NE 4X; IP66; T6 @ 60 C Max. Amb. [HP] Intrinsically Safe Class I, II, III, Division 1, Groups A, B, C, D. Non-Incendive Class I, Division 2, Groups A, B, C, D. Suitable For: Class II, Division 2, Groups F, G. Class III, Division 2. T4A@60 C / T5@40 C Max. Amb. Temp. Canadian Standards Association (CSA) General (Ordinary) Locations Intrinsically Safe [HP]: Class I, Division 1 & 2, Groups A, B, C, D. T4A@60 C / T5@40 C Max. Amb. Temp. TestSafe (Australian) Approvals: Flame-Proof [HP in BH Housing] Ex d IIC T6@60 C European Approvals: CENELEC/ATEX Directive 94/9/EC [HP in BH Housing] Intrinsically Safe II 1G EEx ia IIC T4 Type N II 3G EEx na II T4 T4@60 C Maximum Ambient Temperature Flame-Proof II 2GD EEx d IIC T6@60 C Maximum Ambient Temperature CE Conformant EMC Directive 89/336/EEC EN 61326 * BH HousingGroup A only: Seal all conduits within 18". Specifications and information subject to change without notice. Page 3

PS -PS 1 2 3 4 PS -PS 1 2 3 4 Additional Features Custom Linearization Curves Program your with up to 85 custom linearization points. The ability to plot a custom linearization curve is beneficial when non-linear input signals must be converted to linear output representations. Typical applications include monitoring a non-linear transducer, the level of odd-shaped tanks and flow meter linearization. Monitor Signals Let the make checking the loop easy with its accurate current transmission and large display. And, with an update rate of eight times per second, you can be confident that the display precisely reflects the loop s status. Customized Display The versatile can be programmed to display the input, output or toggle between both. It will also display the engineering unit of your choice (up to five capital letters). PS -PS 1 2 3 4 Long-Term Stability With error rates as low as ±0.09% over a one year period, and ±0.20% for five years, you can schedule calibrations less frequently without sacrificing accuracy. Powerful Isolation Continuous of 500Vac/ 1000Vdc input to output to case will prevent false signals due to ground loops and other noise. Advanced Noise Rejection Filter out 50 or 60Hz noise with our noise rejection feature. Certified Field Enclosures Available Order the in our durable BH enclosure for explosion-proof protection at an affordable price. For applications in rugged environments where explosion-proof protection is not required, choose the NE 4X and IP66 certified D-BOX housing. Convert Signals The takes one process signal type (such as 1-5V) and converts it to a standard, isolated. This allows devices like transmitters and transducers to interface directly with an indicator, recorder, DCS, PLC, or PC-based SCADA system. 4-WIRE 1-5VDC Isolated POWER SUPPLY RECEIVER Solve Bucking Power Supplies When two devices (such as a 4-wire transmitter and a DCS) are trying to source power to a loop, the result is a non-functioning loop. When neither of the devices can be eliminated, the solution is the. It can operate with powered inputs from both sides, thus restoring normal operations to the loop. 4-WIRE 24V 24V DCS Page 4

PS -PS 1 2 3 4 PS -PS 1 2 3 4 PS -PS 1 2 3 4 Stop Ground Noise A difference in potential between a grounded transmitter and a grounded receiving device on the same loop may result in unpredictable ground loop problems, which can lead to signal drift. Use the to break the galvanic path between a field transmitter and an indicator, recorder, DCS, PLC or PC-based SCADA system. This stops the harmful effects of ground loops, motor noise and other electrical interferences. NON- ISOLATED 2-WIRE Ground #1 PS PS Non-isolated Isolated PS ma or PS V POWER SUPPLY POWER SUPPLY RECEIVER Ground #2 Boost Signals If you need to add another instrument to an overloaded loop, use the. It features a high drive capability of 600 ohms (with a 24V power supply) and an input impedance of just 20 ohms. 4-WIRE (into 600 ohms maximum) INTEGRATOR (250 ohms) PID (250 ohms) into 600 ohms 24V RECORDER (250 ohms) Divert and Protect Signals Using the, you can send the output from one transmitter to a second location, protect expensive monitoring/control equipment by eliminating common electrical paths, or create a buffer between devices to allow interruption of one system without impacting the other. ISOLATED 2-WIRE Isolated loop 24V PLC DCS 24V Isolated loop Page 5

One Window. One Minute. One Setup. Configuring the is as simple as point-and-click. All you need is a PC running Windows, our Configuration Software (one copy supplied free with each order), and a configuration cable. In minutes, you can begin configuring your transmitter s: Figure 2. Program the in a minute or less using just this software window. Input type and range (zero and full scale) Output range (, zero and full scale) Noise rejection (50Hz or 60Hz) Direct or reverse output Over or under input range detection Custom instrument tag and serial number Custom input linearization Custom input trimming Fixed output with an easy loop test Damping time for erratic signal compensation (0-20 seconds) Custom LinearizationTables Unusual inputs are not a problem for the. Not when it is so easy to build a custom 85-point linearization table with the Configuration Program s straightforward interface. Output Damping If your sensor is prone to step increases and decreases, use the to lessen the impact on your process. You can program a damping value from 0 to 20 seconds, averaging out sensor fluctuations over the time period setting, and lessening the impact of step changes. On-Screen Setup Confirmation Once programmed, the operating parameters you have selected are constantly displayed in the configuration window. Configuration Alerts Data fields on the configuration window provide alert messages (such as Zero or Full Scale Outside of Conformance Range ) to let you know when you are making a nonstandard or ill-advised selection. Store and Print Files After you ve created a configuration file, it can be downloaded to multiple s, printed out as a hardcopy, or named and stored (on a PC hard drive or other media). Reverse Output Setting Zero Scale Input numerically above Full Scale Input will result in the transmitter s output going up when the input goes down, and vice-versa. When you have chosen this operation, the Output portion of the configuration screen changes to read Reverse Output. Digital Output Trimming A sophisticated yet simple-to-implement software feature allows you to adjust the s output to compensate for inaccuracies in your readout equipment. The Zero Scale Output can be adjusted between 3.797 and 17.400mA. The Full Scale Output adjusts between 7.798 and 21.401mA. Context-Sensitive HELP System Just click on Help, then on the area on the Configuration Screen where you are encountering difficulty, and a concise explanation appears. Page 6

Figure 3. Dimensions of the in a D-BOX Enclosure 130 mm (5.12 in) 116 mm (4.56 in) CONDUIT FITTING BODY BEZEL COVER 118mm (4.65 in) 112mm (4.40 in) 82.6 mm (3.25 in) 64mm (2.50 in) 81mm (3.2 in) INSTRUMENT TAG PS -PS 1 2 3 4 FRONT VIEW SIDE VIEW 84mm (3.30 in) 27mm (1.05 in) Figure 4. Dimensions of the in a BH Enclosure 10mm (.38 in) 129mm (5.06 in) TOP VIEW BOTTOM VIEW 102mm (4.00 in) 84mm (3.30 in) 68mm (2.69 in) PS -PS 1 2 3 4 65mm (2.55 in) 53mm (2.09 in) 124mm (4.90 in) 25mm (1.00 in) SIDE VIEW 66mm (2.60 in) 102mm (4.00 in) FRONT VIEW 57mm (2.25 in) 25mm (1.00 in) GND 1/2 NPT 119mm (4.70 in) 76mm (3.00 in) IDENT TAG Page 7

Signal Isolator/Converter With Display Figure 5. Dimensions of Hockey-Puck with Flange Mount 76mm (3.00 in) 18mm (.70 in) 83mm (3.25 in) 66mm (2.58 in) 61mm (2.4 in) 62mm (2.45 in) PS -PS 1 2 3 4 43mm (1.70 in) 64mm (2.50 in) FRONT VIEW SIDE VIEW Table 1. Terminal Designations. Input Input Output Type Terminals Terminals Terminal Number 1 2 3 4 Left to Right Current Inputs I -I PS -PS Voltage Inputs V -V PS -PS United States info@miinet.com Tel: (818) 894-7111 FAX: (818) 891-2816 Australia sales@mooreind.com.au Tel: (02) 8536-7200 FAX: (02) 9525-7296 Belgium info@mooreind.be Tel: 03/448.10.18 FAX: 03/440.17.97 The Netherlands sales@mooreind.nl Tel: (0)344-617971 FAX: (0)344-615920 China sales@mooreind.sh.cn Tel: 86-21-62491499 FAX: 86-21-62490635 United Kingdom sales@mooreind.com Tel: 01293 514488 FAX: 01293 536852 2006 Moore Industries-International, Inc. Specifications and information subject to change without notice.