W&T Manual Interface modules W&T

Manual Fiber Optic Interfaces

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

Product Manual. USB to Optical Adapter Industrial Isolated RS- 232/422/485. Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M

PCI Express 4-Port Industrial Serial I/O Cards

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

Introduction & Specifications of Hi-Speed USB to Serial Adapters

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

Installation Guide of Hi-Speed USB to Industrial Single RS-422/485 Adapter

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

Media Converters. Media Converters. Product Selection Guides

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

EasySYNC Ltd. USB to Serial Converters Manual

EasySYNC Ltd. USB to Serial Converters Manual

FX-485PC-IF RS485 Interface Unit Hardware Manual

GT- IRDM-9603 Product description Rev. 2 17/06/2014

USB-COM Plus ISO (USB-COMi SI-M)

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

Miniature Asynchronous 4-Wire High Speed Modems

IC-485S /IC-485SI. If anything is damaged or missing, contact your dealer.

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

DATA CONNECT ENTERPRISE

Serial to RS422/485 Converter SER 485 PRO( SI) User Manual

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

Channel Switch CS. General Operating, Maintenance and Installation Manual

GFK-2415A March Type of sensor connection

ME-9000i isolated Serial Interface Board, RS232, RS422, RS485

EasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date:

MGate 4101-MB-PBS Series

Moxa TCC-100 Series User s Guide

ADA User manual ADA RS-485 / RS-422 to RS-232 Converter. 1 io_ada-4010_v3.22_en. Copyright CEL-MAR sp.j.

Serial Interface Modules TTL to RS232/RS485/RS422

Installation & Configuration manual. InduBox GSM IV

Serial Communication Converters & Adapters Instruction Manual

SINAUT ST7 Dedicated Line Modem MD2

SSW7. User Manual. Adapter for MPI-Bus. Version:2 / HW: 1 / FW: 3.0 and higher. Order number of manual: VK21/en VK21

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

Features and Benefits. Certifications

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

ISOLATED RS-232 TO RS-422/485 CONVERTER

Modbus TCP/RTU Gateway

Data Sheet SRM-3A. Ultra-Miniature Isolated Short-Range Async Modem. The Access Company

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

HEC. General Operating, Maintenance and Installation Manual

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

CS485. User s Manual. Version ZYPEX, Inc.

EZL-200F Application Notes (003) Serial Interface (RS232/RS422/RS485)

Product description Rev. 3 11/06/14

MODEL: R2K-1 SEN TRONIC AG. R2K Series

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721

RTU560 Connections and Settings DIN Rail RTU 560CIG10

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

RS 232 to Fibre Optic Modems ELO E240, ELO E241, ELO E242. Operation manual

SER-4485-SI-M USER S MANUAL

Introduction & Specifications of Hi-Speed USB to Industrial Dual Ports RS-422/485 Adapter

MEV Limited USB232/485 INSTRUCTION MANUAL

USB RS485 High Isolated Industry Converter Box for DIN Rail - product #248

Manual W&T. Coupling Relays for Web-IO. Release 1.0 Model

RocketPort Plus Hardware Installation

Installation Guide of Hi-Speed USB to Industrial I/O Adapter

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

FL MC 2000E (SM40) LC

USER S MANUAL SI-700 SI EIA-232/ EIA-485 INTERFACE JUL / 05 SI-700 VERSION 1 FOUNDATION

Product Manual. Single Port RS-232 USB Serial Adapter Optical- ISO Surge Protection. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-COM-Si-M

Unitronics Devices and RS485 Table Of Contents

Standard-Signal Isolation Amplifiers. VariTrans A 21000

Product Manual. 2 Port USB to RS-422 /485 Optical Isolated Adapter. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-2COMi-Si-M

RTU560 Remote Terminal Unit Connections and Settings

Sender Receiver Sender

Select a Data Communication Interface

Data Sheet SRM-6A. Short-Range Asynchronous Modem. The Access Company

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

Installation Guide of Hi-Speed USB-to-Optically Isolated RS-422/485 Adapter

MC 11 EB-2 Power supply cabinet with external bus, AC version

ADAM Fiber Optic to RS-232/422/485 Converter

MAP/950 SERIAL I/O CARD INSTALLATION MANUAL

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Serial/Ethernet Converter

Integrity Instruments Application Notes. Release 1

ICF-1150 Series Quick Installation Guide

Serial PROFIBUS Interface

Cable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB

Industrial Media Converters

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.

USB to RS-232/RS422/485. URK-228-I USB To Serial Operation Manual

RS-232 Industrial Media Converter

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU)

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

MINI MCR-SL-UI-2I(-SP)(-NC)

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

Transcription:

Manual Industry Interfaces W&T Release. Type 0, 0 0, 00 0, 0 0, 0

Industry Interfaces 0/0 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make mistakes, none of our statements should be used without checking. Please let us know of any mistakes or misunderstandings you are aware of, so that we can recognize and eliminate them quickly. Perform work on and with W&T products only as described here and only if you have read and understood the manual fully. Unauthorized use can result in hazards. We are not liable for the consequences of unauthorized use. When in doubt, check with us or consult you dealer! 0

Industry Interfaces Wiesemann & Theis offers with their Industry Interfaces a complete family of interface converters suitable for top hat rail mounting and powered by the V supply commonly used in industrial environments. Trouble-free, noise-immune operation of the associated components is ensured by integrated galvanic isolation between the two interfaces used as well as between the power supply and the interfaces. This interface family is described on the following pages along with the corresponding technical data and including connection examples. For up-to-date information on new developments, see our Internet site at http://www.wut.de or check the e-mail short notices at the W&T Interface Club, which you can also subscribe to from the W&T Homepage. Subject to error and alteration

Industry Interfaces Index General Characteristics and Important Notes... RS <> 0mA Converter, Model 0... RS <> RS/RS Converter, Model 0... RS <> RS/RS Converter with OVP, Model 0... 0mA <> RS/RS Converter, Model 0... RS Isolator, Model 0... RS/RS Isolator, Model 0... RS/RS Isolator with OVP, Model 0... RS Line Driver Set, Model 00...

Industry Interfaces General Charateristics and Important Notes Housing and setting the DIL switches All W&T Industry Interfaces are integrated into a plastic housing for mounting on DIN rails (DIN EN 00-). Some Interface models have DIL switches inside the housing. To set these switches, you must open up the housing. We recommend screwing a SUB-D plug with body onto the Interface and using the plug to help pull the housing cover out of the housing body. Display elements The interface converters feature two LED s, with the Power LED indicating correct supply voltage and the Data LED data communication in both directions. Power Supply The W&T Industry Interfaces in DIN rail housing have a broadrange supply voltage input and can be powered either by a suitable W&T power supply or with an external voltage of between and V AC or DC. The power supply must in any case ensure reliable isolation of the low-voltage side from the mains in accordance with EN00. The supply voltage feed is reverse polarity protected and is accomplished using the included plug-in screw terminal. Subject to error and alteration

Industry Interfaces Galvanic isolation and ESD protection Both ports of all W&T Interface Converters are isolated from each other and from the power supply with a dielectric strength of 000 volts DC. The signals are isolated by means of high-speed optocouplers; energy is supplied to the driver and receiver elements by means of an isolated DC/DC converter. All signal lines of the interface converters are protected against electrostatic discharge of up to kv according to IEC 0-, level. Electromagnetic compatibility and electrical safety All W&T Industry Interfaces meet the limits for noise immunity in industrial environments as well as emissions in commercial and residential areas, so that use of these converters is not subject to any EMC based restrictions. With a maximum permissible supply voltage of V AC/DC (SELV), the described devices do not fall under the Low-Voltage Directive. The power supply must in any case ensure reliable isolation of the low-voltage side from the mains in accordance with EN00. The current Declaration of Conformity for W&T Industry Interfaces can be downloaded in the Internet at the following address: http://www.wut.de/pdf/e-ww0-ww-rdus-000.pdf

Interface RS <> 0mA, Model 0 RS <> 0mA Converter, model 0 The W&T Interface Converter Model 0 permits bi-directional connection of RS devices with components, which are equipped with an 0mA port. Function The interface converts one data line in each direction and provides electrical isolation between the RS side and the 0mA side. Connectors The two ports of the interface use DB male connectors. The connector pin assignments are shown in the table below: RS interface: Pin# Function data in data out active level signal active level 0mA interface: pin# signal Data Out 0mA Data Out + Data Out - Data Out Half Duplex Control Data In 0mA Data In + Data In - Data In Subject to error and alteration

Interface RS <> 0mA, Model 0 Applications A level signal on Pin of the TTY connector will place the 0mA interface of the convertor in half-duplex mode whereby an echo of the sent signals is suppressed. The convertor can be used as an active or passive 0mA component. In the active mode the interface supplies the current required by the respective 0mA loop, while in the passive mode the loop current must be supplied by the connected device. The operating mode can be selected for both loops seperately. Examples of interface switching into active/ passive mode are shown on the following drawings: Interface Tx and Rx loop active RS 0mA PC TxD RxD RTS CTS DSR DTR DIn DOut 0 Data Out 0mA Data Out+ Data Out - Data Out Data In 0mA Data In+ Data In - Data In RxD + RxD - TxD + TxD - passive 0mA device Interface Tx and Rx loop passive RS 0mA PC TxD RxD RTS CTS DSR DTR DIn DOut 0 Data Out 0mA Data Out+ Data Out - Data Out Data In 0mA Data In+ Data In - Data In RxD + RxD - TxD + TxD - active 0mA device Interface Tx loop active, interface Rx loop passive RS 0mA PC TxD RxD RTS CTS DSR DTR DIn DOut 0 Data Out 0mA Data Out+ Data Out - Data Out Data In 0mA Data In+ Data In - Data In RxD + RxD - TxD + TxD - active / passive 0mA device

Interface RS <> 0mA, Model 0 Technical Data Baud rate: Data format: Supported signals: Operating modes: Electrical isolation: Power supply: Current consumption: RS adapter: 0mA adapter: Ambient temperature: Housing / Dimensions: Device weight: Delivery: 0..,00 baud any format RxD, TxD active or passive mode both ports from each other and from power supply with a dielectric strength of 000 volts DC..V DC/AC approx. ma @V DC -pin male SUB-D adapter -pin male SUB-D adapter storage: -0..+0 C operation: 0..+0 C small plastic housing for top hat rail mounting, 0xxmm approx. 0g excl. accessories RS <> 0mA Converter Subject to error and alteration

Interface RS <> 0mA, Model 0

Interface RS <> RS/RS, Model 0 & 0 RS <> RS/ converter, Model 0 & 0 The W&T Interface Converters Model 0 and Model 0 permit bi-directional connection of RS devices with components, which are equipped with an RS or RS port. Function The interfaces convert one data line and one handshaking line in each direction and provide electrical isolation between the RS side and the RS/RS side. Overvoltage protection (Model 0 only) The maximum differential voltage allowed to reach the RS transceiver chip of the interfaces from the outside is around ± V according to the data sheets. Voltage exceeding this amount will inevitably result in destruction of the line drivers. Interface model 0 has integrated overvoltage protection which uses suppressor diodes to limit the maximum voltage to approx. ± V. This overvoltage protection is limited of course by the capacity of the protection diodes used, which can let through a current of 0A for a short time. This means it may not be a substitute for a lightning surge arrestor for long cables in exposed locations (e.g. in the mountains). Subject to error and alteration

Interface RS <> RS/RS, Model 0 & 0 Connectors The two ports of the interfaces use DB male connectors. The connector pin assignments are shown in the table below: RS interface: Pin# Function data in data out handshake out signal handshake in RS/RS interface: Pin# Function data out A (-) data in A (-) handshake out A (-) handshake in A (-) signal data out B (+) data in B (+) handshake out B (+) handshake in B (+) Operating mode The interfaces can be set for five operating modes by DIP switch setting on the RS/RS interface module. The selectable operating modes are briefly described here: RS, RS -wire bus master application One data channel and one handshake channel in each direction are available. The RS/RS receivers and transmitters are always active in this operating mode. RS -wire / -wire application with echo, handshake control One data channel in each direction is available. The RS output driver is activated with a positive RS handshake in signal, while a negative signal forces the driver to high impedance state. The RS receiving channel is always active in this operating mode. 0

Interface RS <> RS/RS, Model 0 & 0 RS, -wire application without echo, handshake control One data channel in each direction is available. The RS output driver is activated with a positive RS handshake in signal, while a negative signal forces the driver to high impedance state. The RS receiving channel is deactivated when the driver is on, but is switched on when the driver is in the high impedance state. RS, wire application / RS -wire application with echo, automatic control One data channel in each direction is available. The RS output driver is activated automatically with each transmission of data, and goes to the high impedance state again after the end of transmission. The RS receiving channel is always active in this operating mode. RS, wire application without echo, automatic control One data channel in each direction is available. The RS output driver is activated automatically with each transmission of data, and goes to the high impedance state again after the end of transmission. The RS receiving channel is deactivated when the driver is on, but is switched on when the driver is in the high impedance state Subject to error and alteration

Interface RS <> RS/RS, Model 0 & 0 Setting the operating modes Please see the following table for an explanation of the operating mode DIP switch: Operating mode SW SW SW SW SW SW RS, RS, -wire bus master OFF OFF OFF ON OFF OFF RS, -wire / -wire with echo, handshake control RS, -wire / -wire without echo, handshake control RS, -wire / -wire with echo, automatic control RS, -wire / -wire without echo, automatic control OFF OFF ON ON OFF OFF ON OFF ON ON OFF OFF OFF ON OFF ON OFF OFF ON ON OFF ON OFF OFF Termination For all RS operating modes it is essential that the bus system be terminated with a termination network which assures a defined rest state in the high-impedance phases of bus operation. The bus system can be connected to a termination network by closing switches # and # on the interface module. +V SW Data In B SW Data In A

Interface RS <> RS/RS, Model 0 & 0 Applications RS hardware handshake application RS RS PC TxD RxD CTS DSR DTR DIn DOut HOut HIn 0 DOut A DOut B DIn A DIn B HOut A HOut B HIn A HIn B RxD A (-) RxD B (+) TxD A (-) TxD B (+) CTS A (-) CTS B (+) RTS A (-) RTS B (+) RS device RS -wire bus master application RS RS PC TxD RxD RTS CTS DSR DTR DIn DOut 0 DOut A DOut B DIn A DIn B RxD A (-) RxD B (+) TxD A (-) TxD B (+) RxD A (-) RxD B (+) TxD A (-) TxD B (+) RS device RS device RS -wire application with handshake control RS RS PC TxD RxD RTS CTS DSR DTR DIn DOut HIn 0 DOut A DOut B DIn A DIn B Bus A (-) Bus B (+) Bus A (-) Bus B (+) RS device RS device RS -wire application with automatic control RS RS PC TxD RxD RTS CTS DSR DTR DIn DOut 0 DOut A DOut B DIn A DIn B Bus A (-) Bus B (+) Bus A (-) Bus B (+) RS device RS device Subject to error and alteration

Interface RS <> RS/RS, Model 0 & 0 Technical Data Operating modes: Switchover delay: Baud rate: Data format: Supported signals: Termination: Electrical isolation: Overvoltage protection: Power supply: Current consumption: RS adapter: RS/RS adapter: Ambient temperature: Housing / Dimensions: Device weight: Delivery: RS RS / wire mode with handshake control RS / wire mode with automatic control approx. 0µs from send to receive for RS automatic control (can be factory changed on request) 0..,00 baud any format RxD, TxD, CTS, DTR Switchable termination network for RS operation both ports from each other and from power supply with a dielectric strength of 000 volts DC Model 0 only: limiting of differential voltage by suppressor diodes to Vmax =,V (Imax = 0A, t = 0ms)..V DC/AC approx. 0mA @V DC -pin male SUB-D adapter -pin male SUB-D adapter storage: -0..+0 C operation: 0..+0 C small plastic housing for top hat rail mounting, 0xxmm approx. 0g excl. accessories RS <> RS/RS Converter

Interface 0mA <> RS/RS, Model 0 0mA <> RS/RS Converter, Model 0 The W&T Interface Converter Model 0 permits bi-directional connection of 0mA devices with components, which are equipped with an RS or RS port. Function The interface converts one data line in each direction and provides electrical isolation between the 0mA side and the RS/RS side. Connectors The two ports of the interface use DB male connectors. The connector pin assignments are shown in the table below: RS/RS interface: Pin# Function data out A (-) data in A (-) signal data out B (+) data in B ( +) 0mA interface: pin# signal Data Out 0mA Data Out + Data Out - Data Out Half Duplex Control Data In 0mA Data In + Data In - Data In Subject to error and alteration

Interface 0mA <> RS/RS, Model 0 Operating modes 0mA interface A level signal on Pin of the TTY connector will place the 0mA interface of the convertor in half-duplex mode whereby an echo of the sent signals is suppressed. The convertor can be used as an active or passive 0mA component. In the active mode the interface supplies the current required by the respective 0mA loop, while in the passive mode the loop current must be supplied by the connected device. The operating mode can be selected for both loops seperately. Examples of interface switching into active/ passive mode are shown on the applications page. RS/RS interface The interface can be set for three operating modes by DIP switch setting on the RS/RS interface module. The selectable operating modes are briefly described here: RS, RS -wire bus master application One data channel and one handshake channel in each direction are available. The RS/RS receivers and transmitters are always active in this operating mode. RS -wire bus systems One data channel in each direction is available. The RS output driver is activated automatically with each transmission of data, and goes to the high impedance state again after the end of transmission. The RS receiving channel is always active in this operating mode.

Interface 0mA <> RS/RS, Model 0 RS -wire bus systems One data channel in each direction is available. The RS output driver is activated automatically with each transmission of data, and goes to the high impedance state again after the end of transmission. The RS receiving channel is deactivated when the driver is on, but is switched on when the driver is in the high impedance state. Setting the operating modes Please see the following table for an explanation of the operating mode DIP switch: Operating mode SW SW SW SW SW SW RS, RS, -wire bus master OFF OFF OFF ON OFF OFF RS, -wire bus system OFF ON OFF ON OFF OFF RS, -wire bus system ON ON OFF ON OFF OFF Termination For all RS operating modes it is essential that the bus system be terminated with a termination network which assures a defined rest state in the high-impedance phases of bus operation. The bus system can be connected to a termination network by closing switches # and # on the interface module: +V SW Data In B SW Data In A Subject to error and alteration

Interface 0mA <> RS/RS, Model 0 Applications Interface Tx and Rx loop active RS 0mA RS device RxD- RxD+ TxD- TxD+ Data Out A Data Out B Data In A Data In B 0 Data Out 0mA Data Out+ Data Out - Data Out Data In 0mA Data In+ Data In - Data In RxD + RxD - TxD + TxD - passive 0mA device Interface Tx and Rx loop passive RS 0mA RS device RxD- RxD+ TxD- TxD+ Data Out A Data Out B Data In A Data In B 0 Data Out 0mA Data Out+ Data Out - Data Out Data In 0mA Data In+ Data In - Data In RxD + RxD - TxD + TxD - active 0mA device Interface Tx loop active, interface Rx loop passive RS 0mA RS device RxD- RxD+ TxD- TxD+ Data Out A Data Out B Data In A Data In B 0 Data Out 0mA Data Out+ Data Out - Data Out Data In 0mA Data In+ Data In - Data In RxD + RxD - TxD + TxD - active / passive 0mA device RS <> 0mA, interface Tx loop active, interface Rx loop passive RS -wire bus 0mA RS device Bus- Bus+ Data Out A Data Out B Data In A Data In B 0 Data Out 0mA Data Out+ Data Out - Data Out Data In 0mA Data In+ Data In - Data In RxD + RxD - TxD + TxD - active/passive 0mA device

Interface 0mA <> RS/RS, Model 0 Technical Data Operating modes: Switchover delay: Baud rate: Data format: Supported signals: Termination: Electrical isolation: Power supply: Current consumption: 0mA adapter: RS/RS adapter: Ambient temperature: Housing / Dimensions: Device weight: Delivery: RS RS / wire mode with automatic control 0mA: active or passive mode approx. 0µs from send to receive for RS automatic control (can be factory changed on request) 0..,00 baud any format RxD, TxD Switchable termination network for RS operation both ports from each other and from power supply with a dielectric strength of 000 volts DC..V DC/AC approx. 0mA @V DC -pin male SUB-D adapter -pin male SUB-D adapter storage: -0..+0 C operation: 0..+0 C small plastic housing for top hat rail mounting, 0xxmm approx. 0g excl. accessories 0mA <> RS/RS Converter Subject to error and alteration

Interface 0mA <> RS/RS, Model 0 0

RS Isolator, Model 0 RS Isolator, Model 0 The W&T RS Isolator Model 0 permits bi-directional connection of two RS devices with an electrical isolation voltage of 000 Volts. Function The isolator supports all data and handshaking lines of pin RS interfaces and has two mutually independent, active RS interfaces. Therefore the isolator can be used as a RS repeater device to double the permissible cable length by inserting the isolator in the middle of the transmission line. Connectors The DTE port of the isolator uses a -pin male SUB-D connector, while the DCE port uses an -pin female SUB-D connector. The connector pin assignments are shown in the table below: RS DCE interface (-pin female) RS DTE interface (-pin male) Pin# Function Direction DCD output RxD output TxD input DTR input DSR output RTS input CTS output RI output Pin# Function Direction DCD input RxD input TxD output DTR output DSR input RTS output CTS input RI input Subject to error and alteration

RS Isolator, Model 0 Applications hardware handshake controlled PC <> modem communication DB male DTE DB female DCE DB male DTE DB female DCE PC TxD RxD RTS CTS DSR DCD DTR RI TxD RxD RTS CTS DSR DCD DTR RI 0 TxD RxD RTS CTS DSR DCD DTR RI TxD RxD RTS CTS DSR DCD 0 DTR RI modem software handshake controlled PC <> PC communication DB male DTE DB female DCE DB male DTE DB male DTE PC TxD RxD RTS CTS DSR DCD DTR TxD RxD RTS CTS DSR DCD DTR RI 0 TxD RxD RTS CTS DSR DCD DTR RI RxD TxD CTS RTS DTR DCD DSR PC Technical Data Baud rate: Data format: Supported signals: Electrical isolation: Power supply: Current consumption: RS DTE adapter: RS DCE adapter: Ambient temperature: Housing / Dimensions: Device weight: Delivery: 0..,00 baud any format RxD, TxD, RTS, CTS, DSR, DCD, DTR, RI both ports from each other and from power supply with a dielectric strength of 000 volts DC..V DC/AC approx. 0mA @V DC -pin male SUB-D adapter -pin female SUB-D adapter storage: -0..+0 C operation: 0..+0 C small plastic housing for top hat rail mounting, 0xxmm approx. 0g excl. accessories RS Galvanic Isolator

RS/RS Isolator, Model 0 RS / RS Isolator, Model 0 The W&T RS/RS Isolator Model 0 permits bidirectional connection of two RS devices or RS bus systems with an electrical isolation voltage of 000 Volts. Function In RS mode the isolator supports one data and one handshaking line in each direction. In RS mode the isolator supports -wire and -wire bus systems. Connectors The two ports of the device use DB male connectors. The connector pin assignments are shown in the table below: Pin# Function data out A (-) data in A (-) handshake out A (-) handshake in A (-) signal data out B (+) data in B (+) handshake out B (+) handshake in B (+) Subject to error and alteration

RS/RS Isolator, Model 0 Operating mode The isolator can be set for three operating modes by DIP switch setting on the RS/RS interface module. The selectable operating modes are briefly described here: RS One data channel and one handshake channel in each direction are available. The RS/RS receivers and transmitters are always active in this operating mode. RS -wire bus systems One data channel in each direction is available. The RS output driver is activated automatically with each transmission of data, and goes to the high impedance state again after the end of transmission. The RS receiving channel is always active in this operating mode. RS -wire bus systems One data channel in each direction is available. The RS output driver is activated automatically with each transmission of data, and goes to the high impedance state again after the end of transmission. The RS receiving channel is deactivated when the driver is on, but is switched on when the driver is in the high impedance state. Setting the operating modes Please see the following table for an explanation of the operating mode DIP switch: Operating mode SW SW SW SW SW SW RS OFF OFF OFF ON OFF OFF RS, -wire bus system OFF ON OFF ON OFF OFF RS, -wire bus system ON ON OFF ON OFF OFF

RS/RS Isolator, Model 0 Termination For all RS operating modes it is essential that the bus system be terminated with a termination network which assures a defined rest state in the high-impedance phases of bus operation. The bus system can be connected to a termination network by closing switches # and # on the interface module: +V SW Data In B SW Data In A Applications RS hardware handshake application RS device RxD A (-) RxD B (+) TxD A (-) TxD B (+) CTS A (-) CTS B (+) RTS A (-) RTS B (+) Data Out A (-) Data Out B (+) Data In A (-) Data In B (+) Hs Out A Hs Out B (+) Hs In A (-) Hs In B (+) 0 Data Out A (-) Data Out B (+) Data In A (-) Data In B (+) Hs Out A Hs Out B (+) Hs In A (-) Hs In B (+) RxD A (-) RxD B (+) TxD A (-) TxD B (+) CTS A (-) CTS B (+) RTS A (-) RTS B (+) RS device RS -wire application RS device RS device Bus A (-) Bus B (+) Bus A (-) Bus B (+) Data Out A (-) Data Out B (+) Data In A (-) Data In B (+) Hs Out A Hs Out B (+) Hs In A (-) Hs In B (+) 0 Data Out A (-) Data Out B (+) Data In A (-) Data In B (+) Hs Out A Hs Out B (+) Hs In A (-) Hs In B (+) Bus A (-) Bus B (+) Bus A (-) Bus B (+) RS device RS device Subject to error and alteration

RS/RS Isolator, Model 0 Technical Data Operating modes: Switchover delay: Baud rate: Data format: Supported signals: Termination: Electrical isolation: Power supply: Current consumption: RS/RS adapter: Ambient temperature: Housing / Dimensions: Device weight: Delivery: RS RS / wire mode with automatic control approx. 0µs from send to receive for RS automatic control (can be factory changed on request) 0.. Mbaud any format RxD, TxD, CTS, DTR Switchable termination network for RS operation both ports from each other and from power supply with a dielectric strength of 000 volts DC..V DC/AC approx. 0mA @V DC -pin male SUB-D adapter storage: -0..+0 C operation: 0..+0 C small plastic housing for top hat rail mounting, 0xxmm approx. 0g excl. accessories RS/RS Galvanic Isolator

RS/RS Isolator with OVP, Model 0 RS / RS Isolator with OVP, Model 0 The W&T Isolator model 0 enables galvanically isolated connection of RS devices and RS bus systems. In addition, the integrated overvoltage protection ensures troublefree operation even under conditions in which overvoltage on the RS line can be anticipated. Function In RS mode the isolator supports one data and one handshaking line in each direction. In RS mode the isolator supports -wire and -wire bus systems. Overvoltage protection The maximum differential voltage allowed to reach the RS transceiver chip of the interfaces from the outside is around ± V according to the data sheets. Voltage exceeding this amount will inevitably result in destruction of the line drivers. The Isolator model 0 has an integrated overvoltage protection which uses suppressor diodes to limit the maximum voltage to approx. ± V. This overvoltage protection is limited of course by the capacity of the protection diodes used, which can let through a current of 0A for a short time. This means it may not be a substitute for a lightning surge arrestor for long cables in exposed locations (e.g. in the mountains). Subject to error and alteration

RS/RS Isolator with OVP, Model 0 Connectors The two ports of the device use DB male connectors. The connector pin assignments are shown in the table below: Pin# Function data out A (-) data in A (-) handshake out A (-) handshake in A (-) signal data out B (+) data in B (+) handshake out B (+) handshake in B (+) Operating mode The isolator can be set for three operating modes by DIP switch setting on the RS/RS interface module. The selectable operating modes are briefly described here: RS One data channel and one handshake channel in each direction are available. The RS/RS receivers and transmitters are always active in this operating mode. RS -wire bus systems One data channel in each direction is available. The RS output driver is activated automatically with each transmission of data, and goes to the high impedance state again after the end of transmission. The RS receiving channel is always active in this operating mode. RS -wire bus systems One data channel in each direction is available. The RS output driver is activated automatically with each transmission of data, and goes to the high impedance state again after the end of transmission. The RS receiving channel is deactivated when the driver is on, but is switched on when the driver is in the high impedance state.

RS/RS Isolator with OVP, Model 0 Setting the operating modes Please see the following table for an explanation of the operating mode DIP switch: Operating mode SW SW SW SW SW RS OFF OFF OFF ON OFF RS, -wire bus system OFF ON OFF ON OFF RS, -wire bus system ON ON OFF ON OFF Setting the switching time In both RS modes of the isolator the respective RS transmitter is automatically placed in the active state as soon as data transmission begins, and turned off again with a time delay at the end of the data telegram. Switch S on the DIL switch bank of the interface modules can be used to set the switching time for the respective interface between send and receive mode to values of 0µs (S = on ) and 0µs (S = off ). The required value for the switching time depends on a number of factors, among which are the baud rate, the response time of the accessed RS slaves, and the overall length of the bus system. For this reason it is not feasible to provide an ideal value for all conceivable applications. In practical terms you should use a value for the switching time which lies in the range of a bit time. At.00 kbaud this would correspond to a time of approx. 0µs, and at slower baud rates you should choose the longer of the two times. Other values are possible by means of a factory component change please contact us if this is something you need. Subject to error and alteration

RS/RS Isolator with OVP, Model 0 Termination For all RS operating modes it is essential that the bus system be terminated with a termination network which assures a defined rest state in the high-impedance phases of bus operation. The bus system can be connected to a termination network by closing switches # and # on the interface module: +V SW Data In B SW Data In A Applications RS hardware handshake application RS device RxD A (-) RxD B (+) TxD A (-) TxD B (+) CTS A (-) CTS B (+) RTS A (-) RTS B (+) Data Out A (-) Data Out B (+) Data In A (-) Data In B (+) Hs Out A Hs Out B (+) Hs In A (-) Hs In B (+) 0 Data Out A (-) Data Out B (+) Data In A (-) Data In B (+) Hs Out A Hs Out B (+) Hs In A (-) Hs In B (+) RxD A (-) RxD B (+) TxD A (-) TxD B (+) CTS A (-) CTS B (+) RTS A (-) RTS B (+) RS device RS -wire application RS device RS device Bus A (-) Bus B (+) Bus A (-) Bus B (+) Data Out A (-) Data Out B (+) Data In A (-) Data In B (+) Hs Out A Hs Out B (+) Hs In A (-) Hs In B (+) 0 Data Out A (-) Data Out B (+) Data In A (-) Data In B (+) Hs Out A Hs Out B (+) Hs In A (-) Hs In B (+) Bus A (-) Bus B (+) Bus A (-) Bus B (+) RS device RS device 0

RS/RS Isolator with OVP, Model 0 Technical Data Operating modes: Switchover delay: Baud rate: Data format: Supported signals: Termination: Electrical isolation: Overvoltage protection: Power supply: Current consumption: RS/RS adapter: Ambient temperature: Housing / Dimensions: Device weight: Delivery: RS RS / wire mode with automatic control selectable 0µs / 0µs from send to receive for RS automatic control (can be factory changed on request) 0.. Mbaud any format RxD, TxD, CTS, DTR Switchable termination network for RS operation both ports from each other and from power supply with a dielectric strength of 000 volts DC limiting of differential voltage by suppressor diodes to Vmax =,V (Imax = 0A, t = 0ms)..V DC/AC approx. 0mA @V DC -pin male SUB-D adapter storage: -0..+0 C operation: 0..+0 C small plastic housing for top hat rail mounting, 0xxmm approx. 0g excl. accessories RS/RS Galvanic Isolator Subject to error and alteration

RS/RS Isolator with OVP, Model 0

RS Line Driver Set, Model 00 RS Line Driver Set, Model 00 The W&T Line Driver Set Model 00 permits bi-directional connection of two RS devices over a distance of up to.00 meters. Function The line driver set consists of two identical interface modules RS <> RS and supports one data and one handshaking line in each direction. To avoid the effects of ground potential difference, both ports of the line driver modules are isolated from each other and from the power supply with a dielectric strength of 000 volts. The line driver modules must be connected to the RS devices by additional shielded serial cables. The pinout of the RS cables is shown in the chapter "Applications" of this manual. Connectors The two ports of the W&T line driver module 00 use DB male connectors. The connector pin assignments are shown in the table below: RS interface: Pin# Function data in data out handshake out signal handshake in RS interface: Pin# Function data out A (-) data in A (-) handshake out A (-) handshake in A (-) signal data out B (+) data in B (+) handshake out B (+) handshake in B (+) Subject to error and alteration

RS Line Driver Set, Model 00 Interconnecting cable To ensure proper operation over long distances, -wire or - wire shielded twisted pair (STP) cable should be employed as interconnection cable. Because of the use of balanced RS interfaces, every transmitted RS signal requires one wire pair of the interconnecting cable. RS software handshake communications therefore require pair STP cables, while communications with two additional hardware handshaking lines require pair STP cables. One cable pair must be used for the inverting line (A) and the non-inverting line (B) of the same signal type. The cable shield shall be connected to the shell of the RS interface at both ends of the interconnecting cable. Applications Bidirectional RS application with hardware handshake pin PC COM interface RS RS RS RS pin RS interface PC TxD RxD CTS DSR DTR DIn DOut HOut HIn 00 DOut A DOut B DIn A DIn B HOut A HOut B HIn A HIn B DIn A DIn B DOut A DOut B HIn A HIn B HOut A HOut B 00 DIn DOut HOut HIn TxD RxD CTS DSR 0 DTR Plotter pin PC COM interface Bidirectional RS application with software handshake RS RS RS RS pin PC COM interface PC TxD RxD RTS CTS DSR DTR DIn DOut 00 DOut A DOut B DIn A DIn B HOut A HOut B HIn A HIn B DIn A DIn B DOut A DOut B HIn A HIn B HOut A HOut B 00 DIn DOut TxD RxD RTS CTS DSR DTR PC

RS Line Driver Set, Model 00 Technical Data Baud rate: Data format: Supported signals: Max. distance: Electrical isolation: Power supply: Current consumption: RS adapter: RS adapter: Ambient temperature: Housing / Dimensions: Device weight: Delivery: 0..,00 baud any format RxD, TxD, CTS, DTR 000m both ports from each other and from power supply with a dielectric strength of 000 volts DC supplied power adapter or..v DC/AC approx. 0mA @V DC -pin male SUB-D adapter -pin male SUB-D adapter storage: -0..+0 C operation: 0..+0 C small plastic housing for top hat rail mounting, 0xxmm approx. 0g excl. accessories RS Line Driver Set Subject to error and alteration

RS Line Driver Set, Model 00