Box Content: - [System] - Inside Extensions - Decoder - Connector Cables - Power Supply Box Refer to Steps: 1 Thru. 4 Please Follow Wiring Steps Carefully. Support Cat5e/6 Cable Or 4-Conductor Cable Quick Wiring Guide Please Follow Wiring Steps ZDL-A60 Push To Answer System Support: -Up To 9999-Inside Extensions -Up To 4-Extensions Per Room -Up To 6-Building Entrances -Audio Extension Support Set: -Date -Time -Alarm Shows -Temp -Hum -Snooze -Mode C/F Call Residents - Set Admin Unlock Code Set Resident Individual Unlock Code Resident s Key-card - Admin Key-card Mail-Man Key-card Required Parts: -Decoder -Power Supply -3-Pin Power/Lock Connector. -3-Pin Decoder Power/Lock Connector. -6-Pin Signal/Panel Add-On Connector 1. To Begin: [Before Powering-On] - Remove panel rear-cover screws to access connection wire. - If wiring Audio Extension Only with panel, or utilizing 8-wire wiring option: [Big [Middle] plug 6-wire + V1 [Brown] & G [Red] wire is all you need to extend to Encoder. Big [Middle] plug 6-wire plus RED & BROWN wire of the 6-wire connector on the right will be required. Big-plug wires connects to IN of Decoder, RED & BROWN wire ties to Decoder Brown [VIN], Red to [VGND]. -Wiring utilizing RJ-45 Plug: Just Plug RJ45 Behind Door Panel & In To The [In] Of Decoder You Can Daisy-Chain Power Wire From Power Supply To Door Panel And Decoder. Monitors Get Power From Decoder. See Detailed Wiring Steps Below ZDL-D04 Decoder ZDL-08037II Power Supply Include: Power / Expansion Connector Cable. Please Remove Cover To Connect Power. Decoder Powers Connected Monitors. Include: AC Power Cable. Wire To: L N & Neutral L = Hot / N = GND / Term.3 = Neutral Tie Decoder 2-Power Wire To: 15V/GND. lock Wire To: PUSH 1 P a g e
1A. Simple Cat5e/6 With RJ45-Plug Wiring Cat5E/6 Wiring: Simply attach RJ45- plug to both End Of cable using 568B- Pinout Method [Straight-thru]. Please follow wiring as shown. Terminated Output RJ45-Male Plug connects to Female RJ45-Plug behind Door Station. Connect other end to the IN of DECODER. Decoder OUT is for expansion. Monitors connect to Ports 1 thru 4. To Next Decoder 1B. Wiring With 4-Conductor 22-18-16-14 Gauge Cable 4-Wire Option: System support very wide variety of cables. -Cat5E/6-22-4 Conductor -18-4 Conductor -16-4 Conductor -14-4 Conductor S System Includes necessary plugs for this option. RJ45-Plugs not included. To Next Decoder Installing with existing regular 4-conductor wire is easy. Most significant connection is between Door Station and Decoder which can be wired using Cat5e/6 wire. Simply tie the big center connector with 6-wire [Blue, Green, Yellow, Orange, Red, Brown] to Decoder 6-wire with exactly same color scheme. Included Power Supply powers both devices. Please refer to the diagram below to see detailed wiring. You have the option to utilize Decoder RJ45-Female Ports or 6-Pin Connector to extend signal to room extensions 2 P a g e
2. System Power Wiring Please Follow Wiring Procedures Carefully. Board Decoder Power Supply Use Of Third-Party Power Supply Is Not Recommended. 2a. Electronic Lock Wiring Please Follow Wiring Procedures Carefully. Support: -Battery 15V Backup You Can: -Wire 2-Exit Buttons [Button Wires Same] Adjust Unlock Time: Lock Unlock Time Is Orange Screw Is Located Right Below NC Terminal Of The Power Supply Box. Turn Clock-wise To: Limit Unlock Time Anti-Clock-wise To: Increase Delay Time Lock Delay 3 P a g e
3. Floor/Room Number Assignment See Diagram Below There is an 8-Pin Jumpers available on each decoder board. [B-A-32-16-8-4-2-1] - Example: Setting Up Floor-1 To 5 [ Jumper-1 Is on the right side] [Floor-1: Remove other jumpers except 1 / Floor-2: Remove others and keep 2] Floor-5: Retain jumper 1 & 4, and remove others. Floor-6: Retain jumper 2 & 4 etc. You Must Retain Jumper-B For Setup Above 4-Floors If You Adopt This Format, Your Room/Extension Numbers Shall Be: On the decoder, Port-1 will be Room-101, 2 will be Room-102 etc.. A floor with over 4-Rooms requires 2 nd Decoder. Port-1 [Always on the right] Will be Room-105, Port-2 Room-106 respectively. [Jumper-A: No Use] Remove Decoder Cover To Locate Jumpers Jumper-1 Just An Option For 4-Wire Connection Room Number Assignment Summary: Example: Application Is For A 6-Storey s Building With Up To 20-Apartments Per Floor Each decoder accepts 4-monitors, which means 5-decoders will be required for first floor 20- apartments. All 5-decoders setting must be similar to the following image: Room Numbers Will Be- 101 Thru 120 Second floor 20-Apartments decoder jumper setting must be similar to the image below: Room Numbers Will Be- 201 Thru 220. Third floor 20-Apartments decoder jumper setting must be similar to the image below: Room Numbers Will Be- 301 Thru 320. Fifth floor 20-Apartments decoder jumper setting must be similar to the image below: Room Numbers Will Be: 501 Thru 520. 4 P a g e
4. Wiring Additional Door Stations Please Follow Wiring Guide Carefully Important Notice: System Support Up To 6-Door Station Panels System support up to 6-Door Stations with unlimited Room Extension. Door Panel-1 monitors other connected Door Panels. Meaning, information programmed in Door Panel-1 automatically updates all attached Door Panels in the chain. Decoder decides how call is routed. Important Tips!!!! Included Power Supply Box supports 1-Door Station + Decoder for up to 20-Room Extensions + 1- Electronic Lock. Extra power supply box will be required for each Door Station especially if Electronic Lock is needed. If installing over 4-extensions, Decoder Power + lock wires can be daisy-chained from decoder to decoder. Use Of Third-Party Power Supply Is Not Recommended. 5 P a g e
Residents Key-Cards/Key-Fobs/Key-Code Assignment Please Follow Wiring Guide Carefully Important Notice: System Support Up To 6-Door Station Panels Key-Cards/Key-Fobs Programming 2-Methods Of Programming Smart Key-Cards/Fey-Fobs - Method-1 [Very Quick] System comes included with 2-Programming Cards [Add & Delete Cards]. You can add multiple by simply showing ADD Card to the inductive area of the Door Station painted black [Card Reader]. Reader should beep once, meaning: [Programming Mode]. You must begin showing your new cards To the reader one at a time within 3-Seconds of hearing that single beep, or else reader will time-out. To Delete: Just swipe DELETE Card on the Reader to Delete/Purge all Key-Card records [ Each Card Has Unique 10-Digit Number Of Its Own, Use This Number To Create Issuing Records] - Method-2 [Use Of Remote Control] This method allows you to key-in actual card number with future possibility of selecting it for deletion. To begin, key-in 1234 + F2 to access system [1234 Is Remote Control System Access Code]. Then key-in [0] to add a Key-Card/Key-Fob, green light shows up immediately. Now, enter Key-Card/Key-Fobs 10- digit Number [Each Key-Card/Key-Fob Has Own Unique Number] + F2. [ F2 Confirms Your Selection *Multiple key-card Addition With Remote Key-in 1234 +F2, and key-in 1 to add multiple key-cards. Green light shows up, then you can swipe card on the reader one at a time. *To Select A Specific Key-Card For Deletion Key-in 1234 +F2, and key-in 2 + 10-Digit Key-Card Number To Be Deleted + F2 to confirm. *Deleting Multiple Key-Cards Key-in 1234 + F2, and key-in 3 to get green light. Then swipe key-cards one at a time. *Delete All Key-Card Records Key-in 1234 +F2, and key-in 4 + F2. Short beep indicates all key-cards deleted. Remote Control Other Functions Remote Control Code-5: Passage Mode [Keeps Attached Electronic Lock Open] 1234 + F2, then 5 + F2. Remote Control Code-6: Locked Mode [Keep Attached Electronic Lock Locked] 1234 + F2, then 6 + F2. Remote Control Code-7: Instant Unlock [Key-in code To Unlock & Auto Lock] 1234 + F2, then 7 + F2 Remote Control Code-8: Change Remote Control Code 1234 + F2, then 8 + F2 [Code Must Be 4-Digit] Important!!!! We Suggest You Keep Factory Remote Control Code & System Access Code To Prevent From Having To Reset All Devices Back To Factory Default. 6 P a g e
Resident s Private Access Key-Code Programming System Default Password: 20021268 Setting Resident s Door Access Codes: Factory System Default Password: 20021268 Setting up door access code for the first resident, enter [**] on the Door Panel Keypad. System should display 1234, and then enter System Default Password: 20021268. 1- - 7 should display on the screen, now enter [3] to display 4-digit blank form [----] [Floor & Room Number]. Key-in 2-digit floor number and 2-digit room number. Should automatically switch screen to display [NE1] and instantly switch to blank form [----] [4-Digit Blank Form] to request new unlock code. Key-in new 4-Digit Unlock Code, and [NE2] will show up then display another 4-digit blank form. Key-in 4-Digit Unlock Code again to confirm. GOOD [Meaning: New Unlock Code Programming Is Successful] should display immediately if unlock code matches. Repeat same steps for all residents.. Unlocking With New Programmed Code: Press the [*] key and enter 4-digit Floor & Room Number, then press [#] to confirm. Enter 4-digit Code and press [#] to unlock. Example: Unlocking With Floor-01 Apartment-01 Tenant Unlock Code- [*] + 0101 + [#] + [Unlock Code] 2134 + [#] To Unlock. System Does Not Support Name List Directory. For Further Assistance Please Contact: Support@ZDLSystems.com 7 P a g e