ZDL-V200. Refer to Steps: 1 Thru. 4 Please Follow Wiring Steps Carefully.

Similar documents
Digital Keypad Introduction

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

Single Door Standalone Access Control User Manual

FTK5 PROXIMITY KEYPAD

WELCOME. For customer support or any inquiries, please visit our web site at or contact us at

Fast operation of IP Villa System V 1.0

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

TELIKOU Intercom System. FM Wire Matrix Control Station. Instruction Manual

Fingerprint Access Control F1. User Manual

Specifications: Features:

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

D O O R S T A T I O N W I T H P R O X I M I T Y R E A D E R

508 SERIES MICROPHONE STATIONS

CM-110SK Standalone Keypad Installation Instructions

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

INSTALLATION INSTRUCTIONS. ACB-100 Audio Control Board. This document describes the installation procedure for the ACB-100 Audio Control Board.

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

Industrial IP67-rated. 4-Port 10/100/1000T 802.3at PoE. + 2-Port 10/100/1000T. Managed Ethernet Switch (-40~75 degrees C, 24V) IGS MP2MT

BLU- CIF Interface Board

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

GV-AS Controller. Installation Guide

Waterproof. Keypad/Reader/Controller

Users Manual for DZ-6306DFR1/V wireless GSM video outdoor station

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web:

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

UC-2000 Installation Manual Unicorn Computers Technology Limited

Upsampling Upgrade for the LINK DAC III Rev #7 (3/2006) Users Manual

EL-ST100 KEYPAD CONTROLLER

GV-AS200 Controller. Hardware Installation Guide

Size of Mounting Plate /2 inches High x 7 inches Wide x 3 1/16 inches Deep (includes circuit boards)

Standalone Access Control

Installation & User Manual

Two-door Access Controller

VIDI-AC-2CS Access Controller/ Reader

Quick Start Installation Guide

User Manual. Split access control with intelligent secured power supply.

ONYX FINGERPRINT PASSWORD LOCK MANUAL

Lab 5: Access Control Training Station

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

GV-AS/EV Controller. User s Manual

NISTA DEVICES GmbH 2013 All Rights Reserved. Door Access Control with the VoIP interface IP epcr Release 1.02

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

VGA EXTENDER USER MANUAL HIT-VGA-CAT5-142WPRO HIT-VGA-CAT5-144WPRO. (Local) HIT-VGA-CAT5-R300WPRO. (Remote)

XR500/XR100 Command Processor Review. a) Zone expanders c) Output expanders b) All of these d) Single point detectors

Wi-Card Skeet-Trap Claymate Operator and User Manual

WiFi Wireless Video Door Phone. User Manual

Fingerprint Access Standalone User s Manual

Agenda. August 23, 2017 Slide 2

Operating Bulletin. Model BB3-232 and BB3-I-232 USB Multi-Drop Box. The Fastest Flow Controller Company in the World!

2000 Series e/em Style Keypad Installation and Programming Manual

Simple Card Reader for Door Access & Time Attendance System. User Guide

PUSH BUTTON PANEL. SECTION 3A (Rev. B) SECTION CONTENTS. Download from Technical Manuals area. sec.3a

Industrial IP67-rated 4-Port 10/100/1000T at PoE + 2-Port 10/100/1000T. M12 Managed Ethernet Switch. (-40~75 degrees C) IGS-604HPT-M12

DOLXFD1000B. Waterproof Access Control/Reader

1. Product Specification

Access control panel U-Prox IC E (Elevator control)

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

7I44 MANUAL 8 CHANNEL RS-422 INTERFACE

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

Installation Instructions (KF-2000)

LevelOne. User Manual KVM-0831/KVM /16-Port Combo KVM Switch w/ Expansion Slot. Ver

Installation & User Manual V2.08

LockState RL 4000 User Guide

BLU- CIF Interface Board

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Physical Specification Vending Machine Card Reader Module Model: CRM-170-xx

INSTALLATION INSTRUCTION MANUAL

Connecting a Cisco Reader Module

180 Series Keypad. Handbook. Revision 2.1

Quick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER

9-3 M03-06, radio/navigation... page M07-, radio... page M07-, navigation... page M06-, radio/navigation...

e-ask electronic Access Security Keyless-entry

MegaTrak MCU-9000 Harness Wiring

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

IC-1504 / IC-1508 / IC-1516

721EX Access Controller Installation

SETUP GUIDE INSTALLATION HANDBOOK. For Integrators, Installers and Administrators. Everything on how to get Kisi up and running. getkisi.

BLU- CIF2 Interface Board

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

User Manual. PCKeypad Wireless Keypad

Model: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated:

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

Unit Door Station User's Manual ----VTO12XX Series

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

SMK585 1U rackmount. With 8 Ports KVM Switch

W3-H Waterproof Keypad/Reader/Controller

ImproX IXP20 Controller INSTALLATION MANUAL

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

Ritelock Pro. icode Programming Guide. (Version 1.XX) 1 User Guide Ritenergy International, LLC

GV-Keyboard Instruction Manual

Modules Programming Guide. paradox.com

ComboCAT Port KVM Switch. User Guide. Rev 0.9

ELK-M1XSP Serial Port Expander

( GRAY CONTROL BOX )

Security Door Controls

Installation Instructions

Transcription:

Box Content: - [System] - Inside Extensions - Decoder - Connector Cables - Power Supply Box Refer to Steps: 1 Thru. 4 Please Follow Wiring Steps Carefully. Support Cat5e/6 Cable Or 4-Conductor Cable Quick Wiring Guide Please Follow Wiring Steps ZDL-A60 Push To Answer System Support: -Up To 9999-Inside Extensions -Up To 4-Extensions Per Room -Up To 6-Building Entrances -Audio Extension Support Set: -Date -Time -Alarm Shows -Temp -Hum -Snooze -Mode C/F Call Residents - Set Admin Unlock Code Set Resident Individual Unlock Code Resident s Key-card - Admin Key-card Mail-Man Key-card Required Parts: -Decoder -Power Supply -3-Pin Power/Lock Connector. -3-Pin Decoder Power/Lock Connector. -6-Pin Signal/Panel Add-On Connector 1. To Begin: [Before Powering-On] - Remove panel rear-cover screws to access connection wire. - If wiring Audio Extension Only with panel, or utilizing 8-wire wiring option: [Big [Middle] plug 6-wire + V1 [Brown] & G [Red] wire is all you need to extend to Encoder. Big [Middle] plug 6-wire plus RED & BROWN wire of the 6-wire connector on the right will be required. Big-plug wires connects to IN of Decoder, RED & BROWN wire ties to Decoder Brown [VIN], Red to [VGND]. -Wiring utilizing RJ-45 Plug: Just Plug RJ45 Behind Door Panel & In To The [In] Of Decoder You Can Daisy-Chain Power Wire From Power Supply To Door Panel And Decoder. Monitors Get Power From Decoder. See Detailed Wiring Steps Below ZDL-D04 Decoder ZDL-08037II Power Supply Include: Power / Expansion Connector Cable. Please Remove Cover To Connect Power. Decoder Powers Connected Monitors. Include: AC Power Cable. Wire To: L N & Neutral L = Hot / N = GND / Term.3 = Neutral Tie Decoder 2-Power Wire To: 15V/GND. lock Wire To: PUSH 1 P a g e

1A. Simple Cat5e/6 With RJ45-Plug Wiring Cat5E/6 Wiring: Simply attach RJ45- plug to both End Of cable using 568B- Pinout Method [Straight-thru]. Please follow wiring as shown. Terminated Output RJ45-Male Plug connects to Female RJ45-Plug behind Door Station. Connect other end to the IN of DECODER. Decoder OUT is for expansion. Monitors connect to Ports 1 thru 4. To Next Decoder 1B. Wiring With 4-Conductor 22-18-16-14 Gauge Cable 4-Wire Option: System support very wide variety of cables. -Cat5E/6-22-4 Conductor -18-4 Conductor -16-4 Conductor -14-4 Conductor S System Includes necessary plugs for this option. RJ45-Plugs not included. To Next Decoder Installing with existing regular 4-conductor wire is easy. Most significant connection is between Door Station and Decoder which can be wired using Cat5e/6 wire. Simply tie the big center connector with 6-wire [Blue, Green, Yellow, Orange, Red, Brown] to Decoder 6-wire with exactly same color scheme. Included Power Supply powers both devices. Please refer to the diagram below to see detailed wiring. You have the option to utilize Decoder RJ45-Female Ports or 6-Pin Connector to extend signal to room extensions 2 P a g e

2. System Power Wiring Please Follow Wiring Procedures Carefully. Board Decoder Power Supply Use Of Third-Party Power Supply Is Not Recommended. 2a. Electronic Lock Wiring Please Follow Wiring Procedures Carefully. Support: -Battery 15V Backup You Can: -Wire 2-Exit Buttons [Button Wires Same] Adjust Unlock Time: Lock Unlock Time Is Orange Screw Is Located Right Below NC Terminal Of The Power Supply Box. Turn Clock-wise To: Limit Unlock Time Anti-Clock-wise To: Increase Delay Time Lock Delay 3 P a g e

3. Floor/Room Number Assignment See Diagram Below There is an 8-Pin Jumpers available on each decoder board. [B-A-32-16-8-4-2-1] - Example: Setting Up Floor-1 To 5 [ Jumper-1 Is on the right side] [Floor-1: Remove other jumpers except 1 / Floor-2: Remove others and keep 2] Floor-5: Retain jumper 1 & 4, and remove others. Floor-6: Retain jumper 2 & 4 etc. You Must Retain Jumper-B For Setup Above 4-Floors If You Adopt This Format, Your Room/Extension Numbers Shall Be: On the decoder, Port-1 will be Room-101, 2 will be Room-102 etc.. A floor with over 4-Rooms requires 2 nd Decoder. Port-1 [Always on the right] Will be Room-105, Port-2 Room-106 respectively. [Jumper-A: No Use] Remove Decoder Cover To Locate Jumpers Jumper-1 Just An Option For 4-Wire Connection Room Number Assignment Summary: Example: Application Is For A 6-Storey s Building With Up To 20-Apartments Per Floor Each decoder accepts 4-monitors, which means 5-decoders will be required for first floor 20- apartments. All 5-decoders setting must be similar to the following image: Room Numbers Will Be- 101 Thru 120 Second floor 20-Apartments decoder jumper setting must be similar to the image below: Room Numbers Will Be- 201 Thru 220. Third floor 20-Apartments decoder jumper setting must be similar to the image below: Room Numbers Will Be- 301 Thru 320. Fifth floor 20-Apartments decoder jumper setting must be similar to the image below: Room Numbers Will Be: 501 Thru 520. 4 P a g e

4. Wiring Additional Door Stations Please Follow Wiring Guide Carefully Important Notice: System Support Up To 6-Door Station Panels System support up to 6-Door Stations with unlimited Room Extension. Door Panel-1 monitors other connected Door Panels. Meaning, information programmed in Door Panel-1 automatically updates all attached Door Panels in the chain. Decoder decides how call is routed. Important Tips!!!! Included Power Supply Box supports 1-Door Station + Decoder for up to 20-Room Extensions + 1- Electronic Lock. Extra power supply box will be required for each Door Station especially if Electronic Lock is needed. If installing over 4-extensions, Decoder Power + lock wires can be daisy-chained from decoder to decoder. Use Of Third-Party Power Supply Is Not Recommended. 5 P a g e

Residents Key-Cards/Key-Fobs/Key-Code Assignment Please Follow Wiring Guide Carefully Important Notice: System Support Up To 6-Door Station Panels Key-Cards/Key-Fobs Programming 2-Methods Of Programming Smart Key-Cards/Fey-Fobs - Method-1 [Very Quick] System comes included with 2-Programming Cards [Add & Delete Cards]. You can add multiple by simply showing ADD Card to the inductive area of the Door Station painted black [Card Reader]. Reader should beep once, meaning: [Programming Mode]. You must begin showing your new cards To the reader one at a time within 3-Seconds of hearing that single beep, or else reader will time-out. To Delete: Just swipe DELETE Card on the Reader to Delete/Purge all Key-Card records [ Each Card Has Unique 10-Digit Number Of Its Own, Use This Number To Create Issuing Records] - Method-2 [Use Of Remote Control] This method allows you to key-in actual card number with future possibility of selecting it for deletion. To begin, key-in 1234 + F2 to access system [1234 Is Remote Control System Access Code]. Then key-in [0] to add a Key-Card/Key-Fob, green light shows up immediately. Now, enter Key-Card/Key-Fobs 10- digit Number [Each Key-Card/Key-Fob Has Own Unique Number] + F2. [ F2 Confirms Your Selection *Multiple key-card Addition With Remote Key-in 1234 +F2, and key-in 1 to add multiple key-cards. Green light shows up, then you can swipe card on the reader one at a time. *To Select A Specific Key-Card For Deletion Key-in 1234 +F2, and key-in 2 + 10-Digit Key-Card Number To Be Deleted + F2 to confirm. *Deleting Multiple Key-Cards Key-in 1234 + F2, and key-in 3 to get green light. Then swipe key-cards one at a time. *Delete All Key-Card Records Key-in 1234 +F2, and key-in 4 + F2. Short beep indicates all key-cards deleted. Remote Control Other Functions Remote Control Code-5: Passage Mode [Keeps Attached Electronic Lock Open] 1234 + F2, then 5 + F2. Remote Control Code-6: Locked Mode [Keep Attached Electronic Lock Locked] 1234 + F2, then 6 + F2. Remote Control Code-7: Instant Unlock [Key-in code To Unlock & Auto Lock] 1234 + F2, then 7 + F2 Remote Control Code-8: Change Remote Control Code 1234 + F2, then 8 + F2 [Code Must Be 4-Digit] Important!!!! We Suggest You Keep Factory Remote Control Code & System Access Code To Prevent From Having To Reset All Devices Back To Factory Default. 6 P a g e

Resident s Private Access Key-Code Programming System Default Password: 20021268 Setting Resident s Door Access Codes: Factory System Default Password: 20021268 Setting up door access code for the first resident, enter [**] on the Door Panel Keypad. System should display 1234, and then enter System Default Password: 20021268. 1- - 7 should display on the screen, now enter [3] to display 4-digit blank form [----] [Floor & Room Number]. Key-in 2-digit floor number and 2-digit room number. Should automatically switch screen to display [NE1] and instantly switch to blank form [----] [4-Digit Blank Form] to request new unlock code. Key-in new 4-Digit Unlock Code, and [NE2] will show up then display another 4-digit blank form. Key-in 4-Digit Unlock Code again to confirm. GOOD [Meaning: New Unlock Code Programming Is Successful] should display immediately if unlock code matches. Repeat same steps for all residents.. Unlocking With New Programmed Code: Press the [*] key and enter 4-digit Floor & Room Number, then press [#] to confirm. Enter 4-digit Code and press [#] to unlock. Example: Unlocking With Floor-01 Apartment-01 Tenant Unlock Code- [*] + 0101 + [#] + [Unlock Code] 2134 + [#] To Unlock. System Does Not Support Name List Directory. For Further Assistance Please Contact: Support@ZDLSystems.com 7 P a g e