CONDUCTOR W Installation instruction for W. and W. 00 Controller To mount the controller. Mounting on a DIN rail Figure. Overview of the Controller. Pos. Product marking. Pos. Termination resistance. = The unit is the last node in the network = The unit is the first node in the network = The unit is situated between the first and last nodes Pos. Modular Contact / ModBUS RTU units (pressure sensor and room unit) Pos. Inputs: Wiring terminals for the connection of sensors. Pos. DIP switch for ModBUS RTU. (=on) boosts the controller to Modbus address (=on) access to Modbus register via BMS system (requires a restart of the controller) Pos. LED, indicates the status of the controller. Pos. Input and output for signal to external relay. Pos. Outputs: Wiring terminals for the connection of valve and damper actuators. Figure. To mount the controller. Pos. Plastic hooks Pos. Supporting surface Pos. DIN rail Pos. Snap-on fastener. To be installed above a false ceiling If a DIN rail is NOT available pre-mounted or is not available, the controller can be appropriately mounted above the false ceiling (not on the module). Product Identification Label Conductor RE W Modbus Adress Artnr: 00 RF id: 000 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIII Figure. Product identification label on the controller. Pos. Name of the product. Pos. ModBus RTU address default from factory. Pos. Part number. Pos. Controller ID number. Figure. To mount the controller. Pos. Supporting surface, NOT for the comfort module or climate beam. Pos. Screws. a. Secure the controller by means of screws in the upper lefthand and the lower right-hand corners. Use screws suitable for the supporting surface.
CONDUCTOR W.- W. (Hotel/Office) Monitoring system via ModBus Figure. CONDUCTOR W.: Integral Components 0 Controller Room unit Presence detector/ Key card Pressure sensor CO External temp. sensor Valve actuator Ventilation damper incl. damper actuator Conductor RE Conductor RU DETECT Occupancy/ SYST SENSO SYST PS DETECT Quality CONDUCTOR T-TG SYST TS- ACTUATOR b V NC CRTc -aaa- (aaa = dimension) Connect the presence sensor, check application parameter P_0 Connect the window contact, check application parameter P_0 Connect the pressure sensor to the Modular contact. Set the address on sensor: SA =, EA = Check application parameters P_, P_0 and P_. (P_0 allways 0 in appl W.) 0 Room unit RJ Modular contact Pressure sensor RJ Modular contact Data (B) MODBUS RS Data (A) Earth Data (B) MODBUS RS Data (A) Earth Resistance Temperature sensor 0 KTY + V AC -G0 0V 0 0V 0V Presence detector 0-0V +V AC -G0 Valve actuator, cooling -G0 +V Valve actuator, heating 0 -G0 +V -G0 Damper, supply air (SA) 0-0V +V -G0 Damper, extract air (EA) 0-0V +V 0-0V Signal CO +V AC -G0 Figure. Wiring diagram, CONDUCTOR W. Swegon reserves the right to alter specifications 00
CONDUCTOR W.- W. (Conference) Monitoring system via ModBus Figure. CONDUCTOR W.: Integral Components 0 Controller Room unit Presence detector Pressure sensor CO External temp. sensor Valve actuator Ventilation damper incl. damper actuator Conductor RE Conductor RU DETECT Occupancy SYST PS DETECT Quality CONDUCTOR T-TG SYST TS- ACTUATOR b V NC CRTc aaa- (aaa = dimension) Connect the presence sensor, check application parameter P_0 Connect the window contact, check application parameter P_0 Connect the pressure sensor to the Modular contact. Set the address on sensor: SA =, SA =, EA = Check application parameters P_, P_0 and P_. 0 Room unit RJ Modular contact Pressure sensor RJ Modular contact Data (B) MODBUS RS Data (A) Earth Data (B) MODBUS RS Data (A) Earth Resistance Temperature sensor 0 KTY Valve actuator, heating +V X -G0 + V AC -G0 0V 0 0V 0V Presence detector 0-0V +V AC -G0 Valve actuator, cooling -G0 +V 0 -G0 Damper, supply air (SA) 0-0V + V -G0 Damper, supply air (SA) 0-0V +V -G0 Damper, extract air (EA) 0-0V +V 0-0V Signal CO +V AC -G0 Figure. Wiring diagram, CONDUCTOR W. 00 Swegon reserves the right to alter specifications
CONDUCTOR W.- b a Figure. Wireless: xaaa, (pos a), Cable: RJ (pos b). Main menu Setup Figure 0. To mount the room unit (thermostat). Pos. Front piece. Pos. Back piece. Pos. Screws suitable for the supporting surface. Recommended installation height RU = standard height for light switches RU should not be exposed to direct sunlight, or other disturbing heat sources. Room air should be able to circulate around the front and sides of the RU. Enter code Service menu Regulator adjust Settings System info General Param. Appl. Param. Alarms k-factor SA Norm SA l/s Boost SA l/s Room unit no. Room temp. Serial Number Battery Level Enter code Enter code k-factor SA Boost SA l/s k-factor EA Offset l/s RF pair-up Language Application Sw. ver. RE Sw. ver. RU Parameter value P_0 ModBus address Min 0 Max Parameter values P_0 or room units Min 0 Max FirstTime func Temp C Temp H RF Quality Temp.calibration Energy saving Backlight Basescreen mode Set point step Commissioning Figure. Overview over the menu system of the room unit. Swegon reserves the right to alter specifications 00
CONDUCTOR W.- Room unit overview RF pair-up (When RJ not used) 0 Main menu Setup <Exit Select> OK sek. Figure. Overview of the main image of the room unit. Press code <Exit > Pos. Cursor key for moving DOWN. Pos. Cursor key for moving to the LEFT. Pos. Heating/cooling. Pos. Battery charge status/window status. Pos. Current airflow. Pos. Operating mode. Pos. Current temperature. Pos. Carbon dioxide content. Pos. Occupancy status Pos 0. Cursor key for moving UP. Pos. Cursor key for moving to the RIGHT. Pos. OK key. <Exit <Exit ModBUS RF pair-up RF Quality 0 RF pair-up 0 0 0 0 Select>... Select> Conductor RE W Modbus Adress Artnr: 00 RF id: 000 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIII Product identification label on the controller. 00 Swegon reserves the right to alter specifications
CONDUCTOR W.- Conductor to BMS and SuperWise First and middle zone Last RE in zone Last zone Last RE in zone 0 WARNING: All electrical installation, including wiring the actuators, valve actuators and various sensors is to be carried out by the electrical contractor or the systems contractor. Safety precautions / Responsibility It is the responsibility of the user to do the following: Assess all the risks involved in the activities which are related to this instruction. Make sure that all necessary safety precautions are made be-fore starting the activities which are related to this instruction. For US and Canada market WARNING: The power feeding shall be a Low Voltage class circuit. Swegon reserves the right to alter specifications 00