BUYERS GUIDE
Index What is Mallory FIRESTORM...3 Features & Benefits...4 What is FIRESTORM? Find out on the next page. Dare to Compare Charts... 5-11 How to Buy... 12-14 New Product Data Sheets...Appendix www.malloryfirestorm.com I 2
Introducing, the FIRESTORM Ignition line from Mallory Ignition Mallory Ignition is hitting the streets with its latest innovation, FIRESTORM! It s so big that we ve created this quick reference guide to help you! Welcome to the Innovative Future of Mallory Ignition! www.malloryfirestorm.com I 3
Features & Benefits: Street Module: Function) enhancement) The Integrated, Intelligent Ignition Control System delivering power, precision, and control unmatched by any competitor for street and race applications. www.malloryfirestorm.com I 4
Spark Energy 150mJ 135 MJ 135 MJ 150mJ 190MJ 190MJ Primary Voltage 550V 535 Volts 535 Volts 550V 535 Volts 535 Volts Secondary Voltage 55,000 Volts 45,000 45,000 55,000 Volts 40,000 40,000 RPM Range 12.5k 12k 12k 12.5k 12K 12K Operating Voltage 9 to 18 Volts 12 to 18 Volts 12 to 18 Volts 9 to 18 Volts 12 to 18 Volts 12 to 18 Volts Current Draw (AMP PER RPM).7 AMP Per 1000.7 AMP Per 1000.7 AMP Per 1000.7 Per 1000 RPM 1.1 AMP Per 1000 1.1 AMP Per 1000 MAX HP 1000 N/A N/A 1000 N/A N/A Cylinder Select 4-6-8 GM HEI GM LT1 FORD TFI Hall Effect Inductive Pickup 4X Low Res Inductive Pickup 36-1 HI RES Points (Square Wave 12V) Data Logging (PRO) Launch Control By RPM By Time By PSI By TPS (PRO) Shift Light/Cam Tach Fuel Pump (PRO) Fan 1 (PRO) Fan 2 (PRO) Malfunction Light Tachometer Dare to COMPARE: Mallory versus MSD on features and benefits. Comparing similar products. 16x16 Timig Table (W/MAP) 3D 2D Curve 3D 2D Curve Individual Cyl Control (PRO) 3D 2D Curve Individual Gear Timing Map 2D Curve 16x16 Step Retard (W/MAP) 3D Curve Single Step 2D Curve 3D Curve 3 STEP 2D Curve Boost Retard 16x16 (W/MAP) 2D Curve 3D 2D Curve continued on pg 6 www.malloryfirestorm.com I 5
Main Rev Limit 2 Step 3 Step Dare to COMPARE: Mallory versus MSD on features and benefits. Comparing similar products. Inlet Air Temp (PRO) Coolant Temp (PRO) Throttle Position (PRO) 1,2,3,4 & 5 BAR MAP Up to 5 BAR Up to 3 BAR Up to 5 BAR Up to 3 BAR Wide Band O2 (PRO) VSS (PRO) Traction Control Real Time Tuning VIA Lap Top Spark Energy 150mJ Inductive 150mJ 110 150mJ 170 Primary Voltage 550V OEM TYPE CD 550V 470 550V 470 Secondary Voltage 55,000 Volts OEM TYPE CD 55,000 Volts 40,000 55,000 Volts 43,000 RPM Range 12.5k OEM TYPE CD 12.5k 14K 12.5k 14K Operating Voltage 9 to 18 Volts OEM TYPE CD 9 to 18 Volts 10-18 Volts 9 to 18 Volts 10-18 Volts Current Draw (AMP PER RPM).7 Per 1000 RPM OEM TYPE CD.7 Per 1000 RPM 10 AMPS @ 10000.7 Per 1000 RPM 10 AMPS @ 10000 MAX HP 1000 N/A 1000 N/A 1000 N/A Cylinder Select 4-6-8 6-8 CYL (2 Required for V8) 36-1 - Cam Sync Requires ECM to Trigger the Coils 6-8 CYL (2 Required for V8) Requires ECM to Trigger the Coils Data Logging (PRO) Launch Control By RPM By Time By PSI continued on pg 7 www.malloryfirestorm.com I 6
By TPS (PRO) Shift Light/Cam Tach Fuel Pump (PRO) Fan 1 (PRO) Fan 2 (PRO) Malfunction Light Tachometer 16x16 Timig Table (W/MAP) 3D 2D Curve 3D 3D Individual Cyl Control (PRO) 3D 16x16 Step Retard (W/MAP) 3D Single Step 1D 3D Single Step 1D 3D Single Step 1D Boost Retard 16x16 (W/MAP) 3D 3D 3D Dare to COMPARE: Mallory versus MSD on features and benefits. Comparing similar products. Main Rev Limit 2 Step 3 Step Inlet Air Temp Coolant Temp Throttle Position 1,2,3,4 & 5 BAR MAP Up to 5 BAR Up to 3 BAR Up to 5 BAR Wide Band O2 (PRO Only) vss Real Time Tuning VIA Laptop PC Want even more? Turn the page! www.malloryfirestorm.com I 7
Spark Energy OEM TYPE CD OEM TYPE CD OEM TYPE CD OEM TYPE CD OEM TYPE CD OEM TYPE CD Primary Voltage OEM TYPE CD OEM TYPE CD OEM TYPE CD OEM TYPE CD OEM TYPE CD OEM TYPE CD Secondary Voltage OEM TYPE CD OEM TYPE CD OEM TYPE CD OEM TYPE CD OEM TYPE CD OEM TYPE CD RPM Range OEM TYPE CD OEM TYPE CD OEM TYPE CD OEM TYPE CD OEM TYPE CD OEM TYPE CD Operating Voltage OEM TYPE CD OEM TYPE CD OEM TYPE CD OEM TYPE CD OEM TYPE CD OEM TYPE CD Current Draw (AMP PER RPM) MAX HP (Limited by Smart Coil) OEM TYPE CD OEM TYPE CD OEM TYPE CD OEM TYPE CD OEM TYPE CD OEM TYPE CD 700 700 700 700 N/A N/A 24X - Cam Sync 58X - Cam Sync Cylinder Select 4-6-8 Data Logging (PRO) Launch Control By RPM By Time By PSI By TPS (PRO) Shift Light/Cam Tach Fuel Pump (PRO) Fan 1 (PRO) Fan 2 (PRO) Malfunction Light Tachometer 16x16 Timig Table (W/MAP) 3D 3D 3D 3D 2D Curve 2D Curve Individual Cyl Control (PRO) 3D 3D 16x16 Step Retard (W/MAP) 3D 3D 3D 3D Single Step 2D Curve Single Step 2D Curve Boost Retard 16x16 (W/MAP) 3D 3D 3D 3D Dare to COMPARE: Mallory versus MSD on features and benefits. Comparing similar products. Igntion Module Igntion Module Igntion Module Igntion Module Igntion Module Main Rev Limit 2 Step 3 Step Igntion Module continued on pg 11 www.malloryfirestorm.com I 8
Inlet Air Temp Coolant Temp Throttle Position 1,2,3,4 & 5 BAR MAP Up to 5 BAR Up to 5 BAR Up to 5 BAR Up to 5 BAR Up to 3 BAR Up to 1 BAR Wide Band O2 (PRO Only) vss Igntion Module Real Time Tuning VIA Lap Top Spark Energy 150mJ 150mJ Inductive Primary Voltage 550V 550V OEM TYPE CD Secondary Voltage 55,000 Volts 55,000 Volts OEM TYPE CD RPM Range 12.5k 12.5k OEM TYPE CD Operating Voltage 9 to 18 Volts 9 to 18 Volts OEM TYPE CD Current Draw (AMP PER RPM).7 Per 1000 RPM.7 Per 1000 RPM OEM TYPE CD MAX HP 1000 1000 N/A Cylinder Select 4-6-8 HEMI - Cam/Crank Sync Data Logging (PRO) Launch Control By RPM By Time By PSI By TPS (PRO) Shift Light/Cam Tach Fuel Pump (PRO) Fan 1 (PRO) Fan 2 (PRO) Dare to COMPARE: Mallory versus MSD on features and benefits. Comparing similar products. Igntion Module Igntion Module Igntion Module Igntion Module Igntion Module Malfunction Light Tachometer www.malloryfirestorm.com I 9
16x16 Timig Table (W/MAP) 3D 3D 2D Curve Individual Cyl Control (PRO) 16x16 Step Retard (W/MAP) 3D 3D Single Step 1D Boost Retard 16x16 (W/MAP) 3D 3D 2D Curve Main Rev Limit 2 Step 3 Step Inlet Air Temp Coolant Temp Throttle Position 1,2,3,4 & 5 BAR MAP Up to 5 BAR Up to 5 BAR Up to 3 Bar 30 PSI Wide Band O2 (PRO Only) vss Real Time Tuning VIA Lap Top Spark Energy 150mJ 150mJ 110 Primary Voltage 550V 550V 470 Secondary Voltage 55,000 Volts 55,000 Volts 40,000 RPM Range 12.5k 12.5k 14K Operating Voltage 9 to 18 Volts 9 to 18 Volts 10-18 Volts Current Draw (AMP PER RPM) 3D.7 Per 1000 RPM.7 Per 1000 RPM 10 AMPS @ 10000 MAX HP 1000 1000 N/A Cylinder Select 4-6-8 6-8 CYL (2 Required for V8) 36-1 - Cam Sync Not a Stand Alone Requires ECM to Trigger the Coils Inductive Pickup 4X Low Res Data Logging (PRO) Dare to COMPARE: Mallory versus MSD on features and benefits. Comparing similar products. Launch Control continued on pg 11 www.malloryfirestorm.com I 10
Activation Switch By RPM By Time By PSI By TPS (PRO) Shift Light/Cam Tach Fuel Pump (PRO) Fan 1 (PRO) Fan 2 (PRO) Malfunction Light Tachometer 16x16 Timig Table (W/MAP) 3D 3D Individual Cyl Control (PRO) 3D 3D 16x16 Step Retard (W/MAP) 3D 3D Single Step 1D Boost Retard 16x16 (W/MAP) 3D 3D Dare to COMPARE: Mallory versus MSD on features and benefits. Comparing similar products. Main Rev Limit 2 Step 3 Step Inlet Air Temp Coolant Temp Throttle Position 1,2,3,4 & 5 BAR MAP Up to 5 BAR Up to 5 BAR Wide Band O2 (PRO Only) vss Real Time Tuning VIA Lap Top www.malloryfirestorm.com I 11
You need it, now here s how to help a consumer buy it... Follow these easy steps to build your FIRESTORM Ignition System! Step 1: Select a FIRESTORM Ignition Box Step 2: Select a Coil or Coil Pack Step 3:Select a Distributor or 36-1 Crank Trigger www.malloryfirestorm.com I 12
Step 3:Select a Distributor or 36-1 Crank Trigger Step 4: Select a Ignition Adapter Harness Step 5: Select a Sensor or Sensor Kit www.malloryfirestorm.com I 13
Step 6: Select Spark Plug Wires Step 7: Select an Accessory Step 8:Select Wide Band 02 Kits Bring to any Mallory Ignition Dealer to get yours W! www.malloryfirestorm.com I 14