Digital Image Processing

Similar documents
Image Acquisition Systems

Tomographic Reconstruction

Introduction to Biomedical Imaging

Ch. 4 Physical Principles of CT

RADIOLOGY AND DIAGNOSTIC IMAGING

Computed Tomography. Principles, Design, Artifacts, and Recent Advances. Jiang Hsieh THIRD EDITION. SPIE PRESS Bellingham, Washington USA

BME I5000: Biomedical Imaging

Joint ICTP-TWAS Workshop on Portable X-ray Analytical Instruments for Cultural Heritage. 29 April - 3 May, 2013

Fundamentals of CT imaging

Index. aliasing artifacts and noise in CT images, 200 measurement of projection data, nondiffracting

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0

Medical Image Processing: Image Reconstruction and 3D Renderings

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Biomedical Imaging. Computed Tomography. Patrícia Figueiredo IST

MEDICAL IMAGING 2nd Part Computed Tomography

Corso di laurea in Fisica A.A Fisica Medica 5 SPECT, PET

Some reference material

CT vs. VolumeScope: image quality and dose comparison

Computer-Tomography II: Image reconstruction and applications

Medical Image Analysis

Emission Computed Tomography Notes

Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT

Medical Imaging BMEN Spring 2016

MEDICAL IMAGING 2nd Part Computed Tomography

Application of 450 kv Computed Tomography to Engine Blocks with Steel Liners

Quality control phantoms and protocol for a tomography system

Computed tomography (Item No.: P )

Central Slice Theorem

8/7/2017. Disclosures. MECT Systems Overview and Quantitative Opportunities. Overview. Computed Tomography (CT) CT Numbers. Polyenergetic Acquisition

Reduction of Metal Artifacts in Computed Tomographies for the Planning and Simulation of Radiation Therapy

New Tools in Aircraft Accident Reconstruction to Assist the Insurer. Overview. Overview 4/30/2015

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

Corso di laurea in Fisica A.A Fisica Medica 4 TC

CT Basics Principles of Spiral CT Dose. Always Thinking Ahead.

Enhancement Image Quality of CT Using Single Slice Spiral Technique

Moscow-Bavarian Joint Advanced Student School 2006 / Medical Imaging Principles of Computerized Tomographic Imaging and Cone-Beam Reconstruction

Biophysical Techniques (BPHS 4090/PHYS 5800)

Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography

Metal Artifact Reduction CT Techniques. Tobias Dietrich University Hospital Balgrist University of Zurich Switzerland

A closer look at CT scanning

Projection and Reconstruction-Based Noise Filtering Methods in Cone Beam CT

Constructing System Matrices for SPECT Simulations and Reconstructions

Recognition and Measurement of Small Defects in ICT Testing

ML reconstruction for CT

MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY. Prof. Yasser Mostafa Kadah

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY

INTERNATIONAL STANDARD

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

Computer-Tomography I: Principles, History, Technology

LAB DEMONSTRATION COMPUTED TOMOGRAPHY USING DESKCAT Lab Manual: 0

Basics of treatment planning II

Computational Medical Imaging Analysis

Computed tomography of simple objects. Related topics. Principle. Equipment TEP Beam hardening, artefacts, and algorithms

An Iterative Approach to the Beam Hardening Correction in Cone Beam CT (Proceedings)

[PDR03] RECOMMENDED CT-SCAN PROTOCOLS

Carestream s 2 nd Generation Metal Artifact Reduction Software (CMAR 2)

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

45 µm polystyrene bead embedded in scattering tissue phantom. (a,b) raw images under oblique

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

Spiral ASSR Std p = 1.0. Spiral EPBP Std. 256 slices (0/300) Kachelrieß et al., Med. Phys. 31(6): , 2004

CT Systems and their standards

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE

School on X-ray Imaging Techniques at the ESRF. Pierre BLEUET. ID22 Beamline

Scatter Correction for Dual source Cone beam CT Using the Pre patient Grid. Yingxuan Chen. Graduate Program in Medical Physics Duke University

Introduction to Positron Emission Tomography

CT: Physics Principles & Equipment Design

Image Restoration. Diffusion Denoising Deconvolution Super-resolution Tomographic Reconstruction

Diagnostic imaging techniques. Krasznai Zoltán. University of Debrecen Medical and Health Science Centre Department of Biophysics and Cell Biology

Continuation Format Page

Medical Image Reconstruction Term II 2012 Topic 6: Tomography

SYSTEM LINEARITY LAB MANUAL: 2 Modifications for P551 Fall 2013 Medical Physics Laboratory

Chapter 32 3-D and 4-D imaging in Obstetrics and Gynecology

Low-Dose Dual-Energy CT for PET Attenuation Correction with Statistical Sinogram Restoration

First CT Scanner. How it Works. Contemporary CT. Before and After CT. Computer Tomography: How It Works. Medical Imaging and Pattern Recognition

Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications

Certificate in Clinician Performed Ultrasound (CCPU)

SUPPLEMENTARY INFORMATION

Visualisation : Lecture 1. So what is visualisation? Visualisation

Cherenkov Radiation. Doctoral Thesis. Rok Dolenec. Supervisor: Prof. Dr. Samo Korpar

Brilliance CT Big Bore.

Simulation of Mammograms & Tomosynthesis imaging with Cone Beam Breast CT images

MEDICAL IMAGE ANALYSIS

Medical Imaging Introduction

INDUSTRIAL SYSTEM DEVELOPMENT FOR VOLUMETRIC INTEGRITY

Computed tomography - outline

Modifications for P551 Fall 2014

Principles of Computerized Tomographic Imaging

Comparison of Probing Error in Dimensional Measurement by Means of 3D Computed Tomography with Circular and Helical Sampling

Computational Medical Imaging Analysis Chapter 4: Image Visualization

High-resolution X-ray CT Inspection of Honeycomb Composites Using Planar Computed Tomography Technology

Discrete Estimation of Data Completeness for 3D Scan Trajectories with Detector Offset

Cardiac Dual Energy CT: Technique

Scaling Calibration in the ATRACT Algorithm

INTRODUCTION TO MEDICAL IMAGING- 3D LOCALIZATION LAB MANUAL 1. Modifications for P551 Fall 2013 Medical Physics Laboratory

Advanced Image Reconstruction Methods for Photoacoustic Tomography

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS

Suitability of a new alignment correction method for industrial CT

Lecture 6: Medical imaging and image-guided interventions

Transcription:

Digital Image Processing SPECIAL TOPICS CT IMAGES Hamid R. Rabiee Fall 2015

What is an image? 2 Are images only about visual concepts? We ve already seen that there are other kinds of image. In this lecture we will consider a special type of medical imaging

Medical Imaging 3 Medical imaging is the technique and process of creating visual representations of the interior of a body It seeks to reveal internal structures hidden by the skin and bones Medical imaging also establishes a database of normal anatomy and physiology to make it possible to identify abnormalities

Medical Imaging Variants 4 X-ray MRI Ultrasound Radionuclide Optical laser Thermography

X-Ray 5 X-radiation (composed of X-rays) is a form of electromagnetic radiation A wavelength ranging from 0.01 to 10 nanometers frequencies in the range 30 petahertz to 30 exahertz (3 10 16 Hz to 3 10 19 Hz) Energies in the range 100 ev to 100 kev X-ray wavelengths are shorter than those of UV rays and typically longer than those of gamma rays

X-ray computed tomography (X-ray CT) 6 It makes use of computer-processed combinations of many X-ray images taken from different angles Produces cross-sectional (tomographic) images (virtual 'slices') of specific areas of a scanned object Allows the user to see inside the object without cutting X-ray slice data is generated using an X-ray source that rotates around the object

X-ray CT (Cont d) 7 A visual representation of the raw data obtained is called a sinogram In terms of mathematics, the raw data acquired by the scanner consists of multiple "projections" of the object being scanned These projections are effectively the Radon transformation of the structure of the object Reconstruction, essentially involves solving the inverse Radon transformation Solution: The technique of filtered back projection

Filtered Back Projection 8 Let's assume that we have a finite number of projections of an object which contains radioactive sources The projections of these sources at 45 degree intervals are represented on the sides of an octagon Now simply run the projections back through the image to obtain a rough approximation to the original The projections will interact contstructively in regions that correspond to the emittive sources in the original image A problem that is immediately apparent is the blurring (star-like artifacts) that occur in other parts of the reconstructed image A high-pass filter could be used to eliminate blurring The combination of back projection and ramp filtering is known as filtered back projection.

Filtered Back Projection Example 9

Other CT s uses 10 Contrast differentiation Three-dimensional reconstruction Multiplanar reconstruction 3D rendering techniques

Multiplanar reconstruction 11 A volume is built by stacking the axial slices The software then cuts slices through the volume in a different plane (usually orthogonal) A special projection method, such as maximum-intensity projection (MIP) or minimum-intensity projection (mip/minip), can be used to build the reconstructed slices

3D rendering techniques 12 Surface rendering A threshold value of radiodensity is set by the operator (e.g., a level that corresponds to bone) A three-dimensional model can be constructed using edge detection image processing algorithms See this link: https://upload.wikimedia.org/wikipedia/commons/d/d4/synchr otron_microtomography_of_atelopus_franciscus_head_- _pone.0022080.s003.ogv

3D rendering techniques (Cont d) 13 Volume rendering Surface rendering is limited in that it will display only surfaces that meet a threshold density In volume rendering, transparency, colors and shading are used to allow a better representation of the volume to be shown in a single image For example, the bones of the pelvis could be displayed as semitransparent So that, even at an oblique angle, one part of the image does not conceal another

Volume rendering Example 14

3D rendering techniques (Cont d) 15 Image segmentation (We will discuss this later if you are interested!) Where different structures have similar radiodensity, it can become impossible to separate them simply by adjusting volume rendering parameters The solution is called segmentation, a manual or automatic procedure that can remove the unwanted structures from the image

Image quality 16 Artifacts Dose vs. image quality

Artifacts 17 Streak artifact: Streaks are often seen around materials that block most X-rays, such as metal or bone Numerous factors contribute to these streaks: undersampling, photon starvation, motion, beam hardening, and Compton scatter

Artifacts (Cont d) 18 Partial volume effect: This appears as "blurring" of edges It is due to the scanner being unable to differentiate between a small amount of high-density material (e.g., bone) and a larger amount of lower density (e.g., cartilage) The reconstruction assumes that the X-ray attenuation within each voxel is homogenous This is most commonly seen in the z-direction, due to the conventional use of highly anisotropic voxels, which have a much lower out-of-plane resolution, than in-plane resolution This can be partially overcome by scanning using thinner slices, or an isotropic acquisition on a modern scanner

Artifacts (Cont d) 19 Ring artifact: Probably the most common mechanical artifact, the image of one or many "rings" appears within an image They are usually caused by the variations in the response from individual elements in a two dimensional X-ray detector due to defect or miscalibration "Rings" are suppressed by a transformation to polar space, where they become linear stripes

Artifacts (Cont d) 20 Noise: This appears as grain on the image and is caused by a low signal to noise ratio This occurs more commonly when a thin slice thickness is used It can also occur when the power supplied to the X-ray tube is insufficient to penetrate the anatomy

Artifacts (Cont d) 21 Motion artifact: This is seen as blurring and/or streaking, which is caused by movement of the object being imaged Motion blurring might be reduced using a new technique called IFT (incompressible flow tomography) Windmill: Streaking appearances can occur when the detectors intersect the reconstruction plane This can be reduced with filters or a reduction in pitch.

Artifacts (Cont d) 22 Beam hardening: This can give a "cupped appearance It occurs when there is more attenuation along a path passing through the center of an object, than a path that grazes the edge This is easily corrected by filtration and software

Dose vs. image quality 23 An important issue within radiology today is how to reduce the radiation dose during CT examinations without compromising the image quality: New software technology can significantly reduce the required radiation dose Individualize the examination and adjust the radiation dose to the body type and body organ examined Prior to every CT examination, evaluate the appropriateness of the exam whether it is motivated or if another type of examination is more suitable

End of Lecture 17 Thank You!