LN Series Input/Output (I/O) Extension Modules and LN Communicating Sensors Subnetwork for LN-VAVCF-12 and LN-PRGxxx-12 Application Note

Similar documents
LN Series Communicating Sensors

LN Series Input/Output (I/O) Extension Modules

LX Series Free Programmable LX-PRG6x0-11 Controllers and LX Series Input/Output (I/O) Extension Modules

Allure EC-Smart-Vue Sensor Series

LN Series Free Programmable LN-PRG6x0-12 Controllers and LN Series Input/Output (I/O) Extension Modules

LN Series Free Programmable LN-PRGxxx-12 Controllers

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

FEATURES DESCRIPTION MODEL 110B. Power Supply

BACnet /IP to MS/TP Adapter User Guide

LN Series Remote Input/Output (I/O) Modules

WT-4000 Wireless System

LN Graphical Programming Interface (GPI) Tool

NCE25 Installation Instructions MS-NCE25xx-x

BACnet vs. Lonworks Specifications (Network Guide)

Hardware Installation Guide

NAE55/NIE55 Installation Instructions MS-NAE55xx-3, MS-NIE55xx-3

BACnet MS/TP CONTINUE

LN Free Programmable PRG 600 Series Controllers

2x4 HDMI 1.3 CAT5e Distribution Amplifier

Application. NAE55 Installation Instructions * S* Installation. Parts included. Materials and special tools needed

MS/TP Communications Bus Technical Bulletin Code No. LIT Software Release 9.0 Issued December 2017

NIE39/NIE49 Installation Instructions MS-NIE39xx-2, MS-NIE49xx-2

XT-9100 Technical Bulletin

LN Application Specific, Remote I/O, and Free Programmable Controllers

FEC26 Field Equipment Controller

USB 2.0 CAT5E/6/7 EXTENDER

BACnet Flow Controller for Fan Filter Units

SCC5-RM. Coloronix, Inc West Jefferson Boulevard Los Angeles, California (323)

NAE55/NIE55 Installation Instructions MS-NAE55xx-3, MS-NIE55xx-3, MS-NAE5510-2U

WR-5e Remote Control

Content. Product Description

LX Series Remote Input/Output (I/O) Controller

MS/TP Communications Bus for the BCProTM System Technical Bulletin

P216 Series Condenser Fan Speed Controller

FX-PCX Expansion Input/Output Modules Catalog Page Code No. LIT Issued April 17, 2015

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

Verasys BACnet MS/TP Communications

FX Input/Output (I/O) Modules XM07 and XM14

Ashly WR-5 Remote Control

How to wire DMX/RDM lighting systems

FX-DIS1710 Local Controller Display Installation Instructions Part No , Rev. B Issued April 2016

2/5/2007 Hints and Tips Support Center Bulletin Revision: 1. Subject: Subject: Echelon Troubleshooting Guide

Wireless Metasys System

Metasys System Direct Connection and Dial-Up Connection Application Note

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 1420A 12-PORT IEEE 802.3AT PSE INTEGRATED CONNECTOR MODULE (PSE-ICM)

USB 2.0 DIGI-USB2 1-Port USB m Category 5e/6/6a/7 Extender Set with Flexible Power. User Manual. Revision

This network (Figure 5) has a Panel-Version Facilitator, Operator Terminal, five controllers, and a repeater.

Hardware Installation Guide

IP7 -SS20. IP Paging Amplifier. Reference Manual

Metasys Database Manager Installation Instructions Code No. LIT Software Release 9.0 Issued August 2017

Serial Communication Converters & Adapters Instruction Manual

IP Speaker System. Users Guide

S300-DIN-RDR2SA Address Mode Configuration

Troubleshooting the NAE/NIE

Ethernet 10Base-T Hub EH-500 EH-800A EH Rev. 3.0

CCS Handheld VAV Balancing Tool Technical Bulletin

Installation & Operation Guide

Cardkey S300 Enclosures

FX-BTCVT Bluetooth Commissioning Converter Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions for UL Rev A

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

PM Series Power Meter

BCM2 Series Branch Circuit Monitors Quick Setup Guide

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

Installation and Operation Guide

Omega 4K / UHD Three-Input Switcher for HDMI and USB-C with HDBaseT and HDMI Outputs

ELK. Computer Sound Card Interface ELK-129. Features. Specifications / Requirements

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

CAT5 1500HD EXT-CAT5-1500HD USER MANUAL.

Metasys Integrator Allen-Bradley Custom Application

SolarVu Installation Guide for Sungrow SG60KU-M Inverter

Installation Guide AT-OPUS-RX

FEC26 Extended Temperature Field Equipment Controller

Integrity Instruments

USB 3.1 CAT6A/7 EXTENDER

Introduction. What is the UC Open controller? Specifications

P2000 Commend Intercom Interface Option

MS/TP Communications Bus Technical Bulletin

Mounting ears as received from NTI. Rear View of ENVIROMUX-S5VDC

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

Audio Networking. Set up a network for easier system control and monitoring.

ADAPTER CARDS TRADITIONAL STANDALONE. DATA SHEET page 1/14. Description

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

EMIT SIM Software Installation and User Manual

Because every network is different, data propagation concerns and the distribution of power must be treated differently.

Omega 4K/UHD Scaler for HDBaseT and HDMI with USB

SeaI/O User Manual. PO Box 830 Liberty, SC

ST/STX GETTING STARTED

Installation Manual. Alpha 4000 RGB Signs. Before you begin

2x8 HDMI 1.3 over Single CAT5 Distribution Amplifier

Carbon Monoxide Sensor - ModBus

EasyIO FW 08VUser Reference

Versatile configuration options

Installation Manual CCL 20 D PTZ camera controller unit DIN-rail mounting

NH908A Amplifier and Power Supply Installation and Use Instructions Used with the HT2006 Series Inside Handset Intercom Stations

LCS85 Turnkey User's Guide Part No , Rev. F Software Release 6.1 Issued June 17, 2013 Supersedes January 30, 2011

WNC1800/ZFR182x Pro Series Wireless Field Bus System Quick Reference Guide

Transcription:

LN Series Input/Output (I/O) Extension Modules and LN Communicating Sensors Subnetwork for LN-VAVCF-12 and LN-PRGxxx-12 Application Note LN-IOE400-0, LN-IOE410-0, LN-IOE420-0, LN-VAVCF-12, LN-PRGxxx-12 Code No. LIT-12011815 Software Release 6.0 Issued January 30, 2013 Refer to the QuickLIT Web site for the most up-to-date version of this document. Document Introduction................................................. 3 Related Documentation................................................. 3 Subnetwork Bus Total Length........................................... 4 Subnetwork.......................................................... 5 Topology and EOL Terminations............................................ 6 Connecting to the LONWORKS Network Through an LN Communicating Sensor................................................. 6 Enabling the Net to Subnet Port Settings Jumper................................. 8 Configuring the LN Communicating Sensor...................................... 9 Connecting to the LON USB Interface......................................... 10 Subnetwork Length...................................................... 10 Physical Specifications and Cable Requirements................................ 11 Addressing.............................................................. 12 LN Series Input/Output (I/O) Extension Modules and LN Communicating Sensors Subnetwork for LN- 1

2

LN Series Input/Output (I/O) Extension Modules and LN Communicating Sensors Subnetwork for LN-VAVCF-12 and LN-PRGxxx-12 Application Note Document Introduction This document describes the subnetwork for the LN Series Input/Output Extension Modules and LN Series Communicating Sensors. The LN-VAVCF0-12 and LN-PRGxxx-12 Series Controllers are equipped with an RJ-45 subnetwork port to quickly connect with subnetwork devices such as the LN Communicating Sensors using a Cat 5e cable (standard patch Ethernet cable). In addition, the LN-PRG6x0-12 Series controllers can also link to the LN-IOE-4x0 I/O Extension Modules through the subnetwork. The subnetwork for the LN-IOE-4x0 I/O Extension Modules uses a standard screw-type terminal block connector and twisted pair shielded cable. This document does not describe how to set up a LONWORKS network. For information on setting up your LONWORKS network, refer to the LONWORKS LN-Series Network Communication and Interface Guide Technical Bulletin (LIT-12011253). Related Documentation Table 1: Related Documentation For Information On See Document LIT Number Setting Up a LONWORKS Network Setting Up a Subnetwork with LN Series Input/Output Extension Modules Subnetwork for LN-PRG6x0-2 Installing LN Free Programmable PRG 600 Series Controllers Installing LN Series Input/Output (I/O) Extension Modules LN Free Programmable PRG 600 Series Controllers and LN I/O Extension Modules Features and Benefits LN Series Communicating Sensors Features and Benefits LONWorks LN-Series Network Communication and Interface Guide Technical Bulletin LN Series Input/Output (I/O) Extension Modules Subnetwork for LN-PRG6x0-2 Application Note LN Free Programmable PRG 600 Series Controllers Installation Instructions LN Series Input/Output (I/O) Extension Modules Installation Instructions LN Free Programmable PRG 600 and LN Input/Output Extension Modules Product Bulletin LN Series Communicating Sensors Product Bulletin LIT-12011253 LIT-12011706 LIT-12011691 LIT-12011693 LIT-12011656 LIT-12011779 3

Subnetwork Bus Total Length The total maximum length of all subnetwork buses, including both the length of the LN Series I/O Extension Modules subnetwork bus and the LN Series Communicating Sensors subnetwork bus is 300 m (1,000 ft). The maximum length of the LN Series I/O Extension Modules subnetwork bus is 300 m (1,000 ft) (Figure 1). The maximum length of the LN Series Communicating Sensors subnetwork bus is 200 m (650 ft) (Figure 2). Figure 1: Maximum Length of the LN I/O Extension Modules Subnetwork Bus Figure 2: Maximum Length of the LN Communicating Sensors Subnetwork Bus with an LN-VAVCF-12 Controller 4

Since the total maximum length of all subnetwork buses cannot exceed 300 m (1,000 ft), the length of one subnetwork bus affects the length of other subnetwork buses. Figure 3 shows that if the LN Series Communicating Sensors subnetwork is 150 m (500 ft), then the LN Series I/O Extension Modules subnetwork length can only be a maximum of 150 m (500 ft). Figure 3: Example of Distribution and Total Maximum Length of Subnetwork Bus Length Subnetwork Figure 4 shows the LN Series Input/Output Extension modules on the subnetwork with the proper End-of-Line (EOL) terminations. Figure 4: EOL Terminations Settings on Subnetwork Note: In Figure 4, the EOL jumpers are located on the inside of the controller and modules. 5

When LN-IOE4x0 modules are installed with an LN-PRG6x0 controller and with LN Communicating Sensors, only the EOL terminations of the last LN-IOE4x0 and the last LN Communicating Sensor are set to ON. All other LN-IOE4x0 modules and LN Communicating Sensors must have their EOL terminations set to OFF (Figure 5). Figure 5: Setting the EOL Terminations on the LN-IOE4x0 Subnetwork Bus When the LN Communicating Sensors Are Used Topology and EOL Terminations Set the EOL terminations on the LN Free Programmable PRG 600 Series Controller and the last LN I/O Extension Module to ON. All other extension modules must have their EOL termination set to OFF (Figure 4). Connecting to the LONWORKS Network Through an LN Communicating Sensor The subnetwork bus extends the LONWORKS network to the LN Communicating Sensors to provide convenient network access for maintenance and troubleshooting purposes (Figure 6). 6

This section explains how to enable the LONWORKS network with the LN Communicating Sensors. A LONWORKS network has a limited number of enabled controllers. Figure 6: LN Communicating Sensors Subnetwork with LONWORKS Network To provide LONWORKS network access, jumpers on both the controller and the LN Communicating Sensor must be enabled. All LONWORKS controllers have Net to Subnet Port Settings jumpers, which (when enabled) connect the LONWORKS network to the LN Communicating Sensor. Note: Only a limited number of controllers on the LONWORKS network segment should have their Net to Subnet Port Settings jumpers enabled. Enabling too many LN Communicating Sensors with network access may cause communication issues. 7

Figure 7 shows a typical LONWORKS network bus topology with only a few controllers enabled for network access at the LN Communicating Sensor. Figure 7: LONWORKS Network Bus Topology For maximum cable lengths and cable specifications for LONWORKS network bus topology, see Table 2. The length of the LN Communicating Sensor subnetwork bus must also comply with the restrictions shown in Figure 1 and Figure 2. Enabling the Net to Subnet Port Settings Jumper To connect the main LONWORKS network to the LN Communicating Sensor subnetwork Cat5e cable, set the two Net to Subnet Port Settings jumpers inside the LN-PRG6x0 controller to Enable (Figure 8). The factory default for the Net to Subnet Port Settings jumpers is set to Disable. Figure 8: Jumpers Set to Enabled on the LN-PRG6x0 Controller 8

To connect the main LONWORKS network to the LN Communicating Sensor subnetwork Cat5e cable, set the two Net to Subnet Port Settings jumpers inside the LN-VAVCF-12 controller to Enable (Figure 9). The factory default for the Net to Subnet Port Settings jumpers is set to Disable. Figure 9: Jumpers Set to Enabled on the LN-VAVCF-12 Controller Configuring the LN Communicating Sensor On each LN Communicating Sensor, ensure that the BAC/LON jumper is set to the LON position (Figure 10). Use this setting for all LN Communicating Sensors, in case you wish to enable the network in the future. Figure 10: LN Communicating Sensor BAC/LON Jumper Set to LON 9

Connecting to the LON USB Interface To temporarily access the LONWORKS network for commissioning and maintenance purposes, connect a LON USB Network Interface to the stereo audio plug located on the lower edge of the LN Communicating Sensor. You can then wire a standard 3.5 mm (1/8 in.) three-conductor (stereo jack) or two-conductor (mono jack) as shown in Figure 11. Figure 11: Connecting to LONWORKS Network via Stereo Jack on LN Communicating Sensor Subnetwork Length The total maximum length of the subnetwork is 300 meters (1,000 feet). The polarity of the LN Series I/O Extension Modules must be configured as shown in Figure 12. All terminals identified as SUBNET+ must be connected to the same conductor. Similarly, all terminals identified as SUBNET- must be connected to the same conductor. Figure 12: LN Free Programmable PRG 600 Series Controllers Subnetwork Shielding 10

Use properly grounded, shielded cable for the best protection against interference on the LN Series I/O Extension Module subnetwork. Use the daisy-chain configuration with the cable shield twisted together and isolated with electrical tape at each extension module. When you use an LN Free Programmable PRG 600 Series Controller, connect the shielding of the extension modules on the subnetwork to the electrical system ground at one point only (Figure 12). Physical Specifications and Cable Requirements Use cables composed of stranded conductors, instead of solid conductors, for the best breakage resistance during pulling operations. Table 2 describes the physical specifications and cable requirements for an LN Series I/O Extension Module subnetwork. Table 2: Physical Specifications and Cable Requirements Specification Description Maximum Number of LN Series I/O Extension Modules Media Characteristic Impedance Distributed Capacitance Maximum Length of the LN Series I/O Extension Modules Subnetwork Polarity Multi-Drop End-of-Line (EOL) Terminations 2 LN Series I/O Extension Modules Shielded, Twisted Pair 100 130 ohm Less than 100 pf per meter (30 pf per foot) 300 meters (1,000 ft) Maximum Polarity Sensitive Daisy-chain (No Routers) Shield Grounding See Figure 12. Built-in and set (enabled) on the last extension module only. 11

Addressing Each LN Series I/O Extension Module on the subnetwork must have a unique address. The current valid addresses are 1 or 2. Figure 13 shows an example of how to set a DIP switch. Table 3 shows the DIP switch settings. Figure 13: DIP Switch Set to 2 Table 3: DIP Switch Settings Switch Position Value 1 2 3 OFF OFF OFF Invalid ON OFF OFF 1 OFF ON OFF 2 ON ON OFF Invalid OFF OFF ON Invalid ON OFF ON Invalid OFF ON ON Invalid ON ON ON Invalid 12 Published in U.S.A. Building Efficiency 507 E. Michigan Street, Milwaukee, WI 53202 Metasys and Johnson Controls are registered trademarks of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 2013 Johnson Controls, Inc. www.johnsoncontrols.com