Swarm. Real-time corrosion and erosion monitoring system. Non-Intrusive Wall Thickness Monitor

Similar documents
PipeMonit Swarm. Real-time corrosion and erosion monitoring system. Non-Intrusive Wall Thickness Monitor

Wall Thickness Monitor

ER DATALOGGER ER-200. Bluetooth Communication Easy data transfer via wireless bluetooth Wireless range up to 32 ft (10m) No more cables required

COSASCO Bluetooth Suite

COSASCO Bluetooth Suite

User Manual ULTRACORR -2 CORROSION MONITORING SYSTEM

Roxar SandLog High Accuracy Sand/Erosion Monitoring

Roxar CorrLog High Accuracy Corrosion Monitoring

Reference Manual. Rohrback Cosasco Systems, Inc. Tel: +1 (562) East Smith Avenue Fax: +1 (562)

Power/RS 485 Comm. Ultrapure Water

ЗАО «БЕРГ АБ», (495) , Intrinsically safe shaft alignment tool with printer

WIRELESS GATEWAY. Features. Model R-1420

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Model R-1420 Wireless Gateway

Remote Asset- Integrity Monitoring

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

FLEX Ex Spring Clamp Terminal Base

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS MT-316-TX

Programming unit VIATOR HART modems Model PU-H

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

General Specifications

The 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel.

MC Toolkit Rugged & Intrinsically Safe models Model MCT404 Specification 34-ST , July 2017

DTM Distributed Transmitter Monitor

General Specifications

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS ET-306-FX

The iwap107 supports 100/1000Base-T, offering a significant increase in speed over the older fast Ethernet standard.

Advanced, Cost-effective, and Reliable HART Communication Products

FTP Factory Trade-In Program

SCADAPack Modbus multivariable transmitter

Level Measurement Continuous level measurement - Ultrasonic transmitters

RHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

Submersible Liquid Level Transmitter Series: PT-500

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Data Sheet Version 1.0

DCT7088 Portable Digital Correlation Transit Time Flowmeter

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX

PRODUCT CATALOG PRODUCT CATALOG.

LS 6600 Technical Datasheet

General Specifications

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Series DMHF Heat Meter

MS2600E High Resolution ER 4-20mA Transmitter Operator s Manual

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

larger, brighter display for ease of use

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. Industrial tablet PC Field device management tools

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE PM MT-336-FX

Operating and monitoring systems Thin Client SERIES 500 Device platform EAGLE PM ET-556-TX

Cygnus Surface Range. Ultrasonic Thickness Gauges. Brilliant Solutions in Ultrasonic Measurement CYGNUS REGIONAL OFFICES

Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291

MGate MB3170/MB3270 Quick Installation Guide

Technical Information Promonitor NRF560

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

Online data sheet. FLOWSIC100 Flare MASS FLOW MEASURING DEVICES

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

Advanced, Cost-effective, and Reliable HART Communication Products

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

Level and Flow Measurement. dbi Transducers. HART and Profibus PA Intelligent Transducers

Skilmatic SI-1Q. Keeping the World Flowing. Spring-Return Electric Quarter-Turn Actuator (65 to 480 Nm)

MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

ICF-1150 Series Quick Installation Guide

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM ET-436-TX

Supplementary Components WirelessHART products

globaltag For Everything You Can t Afford to Lose

SCADAPack Smart RTU

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

Rugged HMI Technology for Hazardous Areas and Extreme Environments in the Oil & Gas Industry

ABB MEASUREMENT & ANALYTICS DATA SHEET. Industrial tablet PC Field device management tools

Flow Measurement SITRANS F C

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

TransPort. PT900 Portable Ultrasonic Flow Meter

ATX JBEA and ECEA Series Aluminum Enclosures Increased Safety

Operating and monitoring systems Panel PC SERIES 400 Device platform SHARK ET-498-2TX

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

DMTFP Portable Ultrasonic Flow Meters

2900 Float & Tape Transmitter

2301E ST Steam Turbine Control for Small Generator Applications

ERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012

µflo 6200 Series Overview 6200 Series Products µflo 6200 Series

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

SCADAPack Modbus multivariable transmitter

Universal IV Water Cut Meter

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

2910 Float & Tape Transmitter

SITRANS F flowmeters SITRANS F US. SITRANS FUH1010 Oil clamp-on. 4/294 Siemens FI

Dräger Polytron 8200 Stationary gas detector (CatEx)

Flow measurement in open channel. Portable Area-Velocity Mainstream EH7000 P. Ultrasonic Area-Velocity Flow meter MAINSTREAM 7000

The TVC Positioner is designed to provide precise position control of rotary or linear hydraulic or pneumatic actuated valve systems.

Trendmaster* Galvanic Isolator

THE TECHNOLOGY BEHIND THE MEASUREMENT

Pioneer Petrotech Services Inc. Proudly Canadian. PPS33 & 33LR RemoteWatcher Multi-Sensor Wireless Monitoring System.

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Model 475 Field Communicator. Connection. Environmental. Shipping Weight

Transcription:

Non-Intrusive Wall Thickness Monitor Real-time corrosion and erosion monitoring system Swarm is a high resolution ultrasonic corrosion and erosion monitoring system which provides rapid response to wall thickness changes in pipes and vessels. It is non-intrusive, installed and operated without interfering with asset production. Swarm provides fast, accurate and repeatable wall thickness measurements which makes it a cost effective tool for realtime monitoring of corrosion and erosion concerns throughout the operators asset. When integrated with our Microcor high resolution ER technology it can also be a highly effective tool to monitor the effectiveness, and optimize chemical inhibitor programs. The Swarm multi array sensor matrix is retrofittable and installed simply by strapping Swarm sensors to the pipe. There is no requirement to remove coatings, no gluing, no welding and no hot work permits required. Swarm wall thickness monitoring is based on the well-established ultrasonic pulseecho method. Non-intrusive Corrosion/Erosion Data Market leading performance with wall resolution better than 0.1 mils, or 2.5 μm Accurate, repeatable wall loss history enables reduced inspection and intelligent pigging activities Swarm and Microcor provide real-time feedback on the effectiveness of corrosion inhibitors makes a significant OPEX saving Accurate and direct erosion monitoring Non-intrusive, installed and operated without interfering with asset production Easy Installation and Maintenance Sensors are retrofittable for easy relocation Fast, maintenance free installation No requirement to remove coatings No need for maintenance or calibration after installation Communication Modbus TCP or OPC for easy integration to client control systems Online or data logging Bluetooth or USB communication between the Portable and Field Data Loggers Hazardous Area Certifications Intrinsically safe ( IECEx/ATEX/ C CSA US ) Certified for use in Class 1, Zone 1 areas IP67 rated enclosure for S1 Transducers IP66 rated enclosure for FDL All specifications and content are subject to change.

How the Swarm Wall Thickness Monitoring System Works Swarm S1 ultrasonic sensors measure absolute wall thickness providing market leading resolution for wall thickness loss. Swarm consists of multiple daisy chained S1 sensors organized in a customized matrix to cover a bend, straight pipe, a weld, a T-piece, a vessel or a tank. The Swarm is connected to an FDL (Field Data Logger) or SDL (Safe Data Logger) for autonomous operation. The SDL operates and stores data locally, in addition to providing the data via Modbus/OPC interface. The FDL operates and stores data locally providing online real-time wall thickness monitoring when connected to a Cosasco PC or Server via GSM. The PDL communicates with the FDL via Bluetooth and provides the operator with graphical presentations of wall thickness data and corrosion rates. Online Monitoring using an SDL via Modbus/OPC in Safe Area Online Monitoring using an SDL via Modbus/OPC in Hazardous Area Online Monitoring using an FDL EX via GSM or Ethernet in Hazardous Area

Safe Data Logger (SDL) The SDL is hard wired (RS 485) to the Swarm using a two pair IS instrumentation cable. Utilizing one or more extension kits the number of Swarm S1 channels connected increase with 16 per kit. The SDL performs daily readings (configurable) of the Swarm and communicates with the control system via Modbus TCP. Specifications Technical Data Swarm S1 sensor channels 16 Extension kit available for additional 16 Swarm S1 Sensor channels Operating temperature Yes -20 to +50 C (-4 to +122 F) Electrical Data Power supply Typical power consumption 12-24 VDC or 110/240 VAC <20 W Swarm interface RS485 Main communication interface Data download Modbus TCP USB 2.6 (67 mm) 5.7 (145 mm) 7.7 (195 mm)

Swarm S1 Swarm S1 ultrasonic sensors measure absolute wall thickness providing market leading resolution for wall thickness loss. Swarm consists of multiple daisy chained S1 sensors organized in a customized matrix to cover a bend, straight pipe, a weld, a T-piece, a vessel or a tank. The Swarm is connected to a USB Junction box for manual capture of data, a FDL (Field Data Logger) or SDL (Safe Data Logger) for autonomous operation. Specifications Technical Data Ultrasound channels 1 Ultrasound frequency ~5 MHz Pipeline operating temperature Temperature sensor Ambient operating temperature Pipe size Wall thickness Coating materials Repeatability Temperature compensation Wall Loss Rate Resolution Retrofittable Non-intrusive Weight Ingress protection Ex rating Electrical Data Supply Voltage Power consumption (typical) Communication interface Connector type -40 to +125 C (-40 to +257 Fahrenheit) -40 to +125 C +- 0.1 C (-40 to +257 Fahrenheit) -40 C to Ta 80 C (-40 F to Ta 176 F) @ Pi 1.7 W (Limited barrier for up to 8 sensors) -40 C to Ta 55 C (-40 F to Ta 131 F) @ Pi 2.5 W (Standard) 4 inches > 3 mm (0.12 inches) Works through external FBE and homogeneous PE/PP coatings <2.5 µm (0.1 mils)* ±20 C between 2 measurements 0.04 mm (1.7 mils)/year in 30 days or 0.002 mm (0.08 mils)/year in 365 days assuming 1 daily reading, 95% confidence, 10 mm wall thickness and a temperature error of +-1 C Yes Yes 80 x 45 x 50 mm (3.15 x 1.77 x 1.97 in) 0.3 kg (0.66 lb) IP67 Europe: ATEX: Ex ib IIB T4 Gb IECEx: IEC Ex ib IIB T4 Gb : Class 1, Zone 1 AEx ib IIb T4 C CSA US 12 to 24 VDC < 1 W (Active), < 0.1 W (Idle) RS-485 (2 connectors) 4 pin, Sealed *Repeatability is defined as one standard deviation for repeated measurements on an object with no corrosion and at constant temperature over the measurements.

Application Swarm s unique design allows for installation on critical areas such as top of welds, heated weld zones, elbows, and T-pieces. Swarm Matrix of Sensors Installed on Bend Swarm Matrix of Sensors Installed on Weld Swarm Matrix of Sensors Installed on T-Piece 1.5 (38 mm) 2.2 (57mm) 3.1 (80 mm) 1.8 (45 mm) 3.1 (80 mm) 3.1 (80 mm) 1.8 (45 mm) 1.3 (33 mm) 0.6 (16 mm)

Portable Data Logger The PDL and PDL Ex are Windows based rugged tablets with PipeView application software. The PipeView application includes everything needed for installation, commissioning and operation of any Swarm system. During installation, simply connect the PDL (Ex) and configure the swarm utilizing the installation tool application. Specifications Technical Data Portable Data Logger (PDL) Portable Data Logger Ex (PDL Ex) Output data Wall thickness data, corrosion/erosion rates, raw signals, temperature Wall thickness data, corrosion/erosion rates, raw signals, temperature Operating temperature -21 C to 50 C/-5.8 F to 122 F -10 C to 50 C/ 14 F to 122 F Storage temperature -40 C to 71 C/-40 F to -40 F to 160 F -10 C to 50 C/ 14 F to 122 F Screen 12 TFT LCD HD 10.1 AHVA Full HD Plus RAM 4 Gigabyte 4 Gigabyte Storage 128 Gigabyte 64-128 Gigabyte Ex rating NA ATEX Zone 1, IECEx Zone 1 and UL C1D1 Electrical Data Power supply Rechargeable Li-Ion battery (up to 8 hours battery time, up to 2 hours in sub-zero temperature) Rechargeable Li-Ion battery (up to 12 hours battery time, up to 1 hours in sub-zero temperature) 10.7 (273 mm) 7.3 (185 mm) 0.7 (17 mm)

Field Data Logger Ex The Swarm Field Data Logger Ex (FDL Ex) is hard wired (RS 485) to the Swarm using a two pair IS instrumentation cable. In semi-automated mode the FDL Ex performs daily logging of the Swarm and stores the data locally. With one reading a day the storage capacity will be 9 months for a 16 sensor Swarm unit. In fully automated mode the FDL Ex performs daily readings of the Swarm and communicates the data online and real-time over Ethernet or GSM. The FDL Ex is powered by battery or via hard wire 12/24 VDC or 110/230 VAC. Specifications Technical Data Swarm S1 sensor channels 16 Operating temperature Weight Cable length Material Ingress protection Ex rating -20 to +50 C (-4 to +122 F) 389 x 195 mm (15 x 7.7 in) 29 kg (64 lbs) (RS485) standard 10 m (33ft) between FDL-EX and Swarm 316SS IP66 Atex Ex II 2 G, Ex d e [ia Ga] IIC T6 Gb Electrical Data Power supply Typical power consumption Communication options PipeMonit unit compatibility 12-24 VDC or 110/240 VAC or internal alkaline battery pack <9 W RS485, Bluetooth, GSM, Ethernet Portable Data Logger, Swarm Ø 7.7 (195 mm) 7.1 (181 mm) 14.3 (363 mm) 7.9 (200 mm) 10.1 (256 mm)

Ordering Information Swarm Safe Datalogger Part Number Description 1037163 Swarm SDL System 16 Channel Modbus, w/ Sensorlink Std Modbus Map 1037206 Swarm SDL Extension Kit 16 Channel IS barriers and Power Supply Swarm Field Data Logger Ex Part Number Description 1037160 Swarm Field Data Logger Ex Mains Power, Battery and Bluetooth. Swarm Portable Data Logger Ex Part Number Description 1037164 Swarm Portable Data Logger Ex Swarm S1 Ultrasonic Sensors Part Number Description 1037227 Swarm S1 Ultrasonic Sensor IECEx/ATEX 1037230 Swarm S1 Ultrasonic Sensor C CSA US /IECEx/ATEX Accessories/Spare Parts Part Number Description 1037152 Swarm Standard Bracket Low 1037150 Swarm Standard Bracket High 1037216 Swarm S1 Gasket Protection Gasket for Transducer on Swarm S1 1037214 Swarm Positioning Tool to Adjust Swarm Sensor Location. 1037726 Swarm - USB to Serial Converter Cable 1037169 Swarm - 0.3m Jumper Cable 1037170 Swarm - 0.5m Jumper Cable Jumper 1037171 Swarm - 1.0m Jumper Cable Jumper 1037172 Swarm - 10m Connection Cable From 1st Swarm to FDL/JB 1037173 Swarm - Band Buckle 1037212 Swarm Battery Pack Ex 1037208 Metal Mounting Strap 1037209 Protective Galvanic Isolation Tape 1037210 Echo 8 Couplant *Individual installation kit parts are based upon number of sensors, locations, and pipe size. Contact Cosasco sales representative for quantities. Cosasco 11841 Smith Avenue Santa Fe Springs, CA 90670, USA Tel: 1-562-949-0123 Email: sales@cosasco.com Web Site: www.cosasco.com Swarm-DSrevA Rev. Date 5/2/2018 Rohrback Cosasco Systems, Inc. All rights reserved The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described wherein or their use or applicability. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. www.cosasco.com