Brocade approved solutions for 16/10/8G FC SAN connectivity

Similar documents
Getting more from dark fiber

Expanding your network horizons

Expanding your network horizons

16G Fibre Channel SAN Connectivity

OPTICAL TRANSCEIVERS. Harnessing more network power

SAN Distance Extension Solutions

Company Introduction. SmartOptics products now make optical networking, especially 4G, 8G and 10G connectivity, simple and affordable.

- 128 x Gigabit Ethernet connections - 32 x 4G Fibre Channel connections - 8 x 8G Fibre Channel connections - down to 2 Mbps

Smartoptics Support Statement

OptiDriver 100 Gbps Application Suite

REDUCING CAPEX AND OPEX THROUGH CONVERGED OPTICAL INFRASTRUCTURES. Duane Webber Cisco Systems, Inc.

MX Ring. WDM - MUX/DeMUX. MUX/DeMUX. Features Full native mode performance Optical connectors Passive model requires no power.

Name of Course : E1-E2 CFA. Chapter 15. Topic : DWDM

5U CWDM Managed Platform SML-5000

Optical Transport Platform

Lowering the Costs of Optical Transport Networking

METRO/ENTERPRISE WDM PLATFORM

Brocade Fabric OS 7.x Compatibility Matrix

Dell Networking Optics and Cables Connectivity Guide

MetroWAVE CWDM REFERENCE GUIDE

Why Service Providers Should Consider IPoDWDM for 100G and Beyond

Data Center Workshop. Rolle, Mars 2008 DataCenter par la face optique

Brocade Fabric OS 8.x Compatibility Matrix

Coarse and Dense Wavelength Division Multiplexing

Open Cloud Interconnect: Use Cases for the QFX10000 Coherent DWDM Line Card

ERicsson pau 140o family photonic attachment unit

Arista AgilePorts INTRODUCTION

Arista 7500E DWDM Solution and Use Cases

Cisco MDS 9000 Family Pluggable Transceivers

Cloud Interconnect: DWDM Integrated Solution For Secure Long Haul Transmission

OPTICAL LAYER PLUGGABLES: THE END OF HARD CHOICES IN THE METRO?

Lean Disaggregated Regional Optical Transport. Nick Plunket, Interconnection Engineer NANOG 74 October 2 or 3, 2018

Optical Networking Solutions

Scale-Out Architectures with Brocade DCX 8510 UltraScale Inter-Chassis Links

BRINGING PACKET-OPTICAL NETWORKING TO THE NEXT LEVEL THE TRANSMODE TM-SERIES

Data Center Applications and MRV Solutions

Product Overview. Send documentation comments to CHAPTER

Updated in Free Product Guide for Your Network. WDM & FTTx. Catalog

Transport is now key for extended SAN applications. Main factors required in SAN interconnect transport solutions are:

As enterprise organizations face the major

Data Center & Cloud Computing DATASHEET. FS.COM WDM Transport Networks Data Center & Cloud Computing Infrastruture Solutions

Coriant Groove G30 Network Disaggregation Platform

CONVERGE EXTEND SWITCH AGGREGATE CONNECT CONNECT SWITCH CONVERGE EXTEND AGGREGATE. BTI 7000 Series BTI Product Brochure. the network you need.

OPCOM600 series CWDM/DWDM System

Brochure. WDM Solutions. Methods for Optimizing Fiber Capacity. Transition Networks Brochure.

FLASHWAVE 7120 Micro Packet Optical Networking Platform

Plexxi LightRail White Paper

IBM expands multiprotocol storage offerings with new products from Cisco Systems

Using Optical Transport in the Campus Environment

Dynamic Optical Transport for Metro, Regional and Long Haul DWDM 10G >100G

EKINOPS 360. Dynamic Optical Transport for Metro, Regional and Long Haul SMALL FORM FACTOR LOW-POWER CONSUMPTION LEADING EDGE TECHNOLOGY

CWDM CASE STUDY DESIGN GUIDE. Line Systems, Inc. uses iconverter CWDM Multiplexers to overlay Ethernet onto SONET rings

Cabling Solutions for Nexus 9000 Switches With Dual-Rate 40/100G BiDi Transceiver and Panduit Connectivity

SAN extension and bridging

DATA CENTER. Metro Cloud Connectivity: Integrated Metro SAN Connectivity in 16 Gbps Switches

BWDM CWDM DWDM WDM TECHNOLOGY

100G DWDM QSFP Datasheet

Lambda Networks DWDM. Vara Varavithya Department of Electrical Engineering King Mongkut s Institute of Technology North Bangkok

Accelerate Your Digital Transformation

IBM Europe Announcement ZG , dated February 13, 2007

BROCADE OPTICS FAMILY

Optical Loss Budgets

Installation Notes for the Catalyst 3750-X and 3560-X Network Modules

Telecom Engineering DWDM/CWDM Lite Manual

CAPACITY UPGRADE THROUGH 40G

Arista 400G Transceivers and Cables: Q&A

SWITCHlambda Update Felix Kugler, SWITCH

About ProLabs. A leading provider of OEM compatible networking solutions. Changing the Data Center Mindset. The ProLabs Advantage

DELL EMC NETWORKING TRANSCEIVERS AND CABLES

SFP GBIC XFP. Application Note. Cost Savings. Density. Flexibility. The Pluggables Advantage

BT Connect Networks that think Optical Connect UK

Data Center Connectivity

Next Generation Broadband Networks

SLIDE 1 - COPYRIGHT G. Across the country, Across the Data Centre. Tim Rayner. Optical Engineer, AARNet.

Delivering100G and Beyond. Steve Jones Phone: blog.cubeoptics.

Installation Notes for the Cisco TwinGig and OneX Converter Modules

REDUCING THE COST OF METRO FIBRE ACCESS A SOLUTION GUIDE FOR SERVICE PROVIDERS

ProLabs new product releases

Universal Network Demarcation. Enabling Ethernet and wave services with the Nokia 1830 PSD. Application note. 1 Application note

Fibre Optic Communications - Networking

Retired. HP CWDM Slot B 4-port Add/Drop Multiplexer. HP CWDM 8-port Multiplexer HP CWDM Multiplexer 2-Slot Chassis

Sharing optical infrastructure - from small site integration to multi-domain backbone links

Brocade Ethernet Optics Family

QUESTION: 1 You have been asked to establish a design that will allow your company to migrate from a WAN service to a Layer 3 VPN service. In your des

An Oracle White Paper April Metro Cloud Connectivity: Integrated Metro SAN Connectivity in 16 Gb/sec Switches

INNOVATIVE PACKET-OPTICAL NETWORKS FROM ACCESS TO CORE THE TRANSMODE TM-SERIES

Introduction To Optical Networks Optical Networks: A Practical Perspective

Cloud Optimized Performance: I/O-Intensive Workloads Using Flash-Based Storage

Cisco 100GBASE QSFP-100G Modules

Demarcation Extension: Challenges and Solutions

Brocade ICX 7250 Switch Frequently Asked Questions

Japan Network. The Level 3 Global Network. Trans-Pacific and Asian Networks. Outline. The Level 3 Network. Metropolitan. Transport Network.

Alcatel 1696 Metro Span. Metropolitan DWDM System

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 40 Channels C21-C60 Dual Fiber DWDM Mux Demux + Monitor Port. 1U Rack Mount, LC/UPC

Fiber Optic Cabling Systems for High Performance Applications

THE DATA CENTER TRANSFORMATION IS UNDERWAY IS YOUR STORAGE AREA NETWORK READY?

World s Largest Supplier of Optical Solutions for the Communications Industry. Investor Relations Presentation November 30, 2011

Brocade Fabric OS 8.x Compatibility Matrix

Netherlands = Finland?

iaccess Multi-Service Platform-DM In Band Managed Multi-Service Platform-FRM220 Series

Transcription:

Brocade approved solutions for 16/10/8G FC SAN connectivity Using Wavelength Division Multiplexing to expand network capacity Smartoptics provides qualified embedded CWDM and DWDM solutions for Brocade Fibre Channel and VDX switches. Embedded solutions, where transceivers reside in the switch, offers the most cost effective and simple approach to WDM networking. A solution brief from Smartoptics

Braocade approved CWDM/DWDM solutions for 16/10/8G connectivity Smartoptics provides 16/8G Fibre Channel (FC) CWDM and DWDM connectivity solutions certified in the latest Brocade 16 and 32G FC switche. Simple to use and cost effective open line connectivity solutions. The Brocade and Smartoptics solution Smartoptics offer optical transmission solutions based on Coarse Wavelength Division Multiplexing (CWDM) and Dense Wavelength Division Multiplexing (DWDM) that help expand network capacity. Our embedded solutions enable long distance CWDM/DWDM transceivers to be connected directly into the Brocade switch rather than through a traditional DWDM platform. The design uses a single passive optical multiplexer to generate up to 16 CWDM or 80 DWDM channels through a single pair of fibers to support distances up to 70 km. With this approach, capex and opex are significantly reduced compared to active DWDM networking platforms. System capacity is the same as a traditional DWDM platform, but with far fewer elements at risk of failure. Reduced power, cooling, and space requirements result in the ultimate green data center solution. For longer distance connectivity, Smartoptics innovative platform is an intelligent 1U DWDM passive multiplexer with integrated amplifier and monitoring features. It works with any combination of embedded DWDM transceivers and transponders to extend distances up to 200km point to point. Longer in repeater mode. Embedded 16/10/8G FC connectivity Support for ELWL, CWDM and DWDM Open line networking Power and cooling costs reduced by 40 to 60 percent Rack space footprint reduced by 80 percent No buildup of DWDM transmission knowledge or costs 32G FC switch support (G620, X6, SX6) 2.

Simple and intelligent CWDM/DWDM multiplexing for open line networking A transponder solution for carriers and service providers offers many functions not needed in the datacom environment. These include individual cards providing functions for transforming a short range signal to a long range signal, amplifying the signal, signal conditioning, dispersion compensation, and network management, all of which are important to the kind of system a carrier or service provider needs but not for the relatively simple task of securely transporting large amounts of traffic between data centers. These systems bring a need for large real estate requirements, along with a need for additional telecom transmission knowledge to operate and manage them. The result is a fairly cumbersome, even clumsy, vertically integrated chassis based system. DWDM line cards Fans Power supplies Mux/Demux Tx & Rx DCMs NBI Network manager Craft terminal Element manager TL1/CLI An active CWDM/DWDM solution is a powered system, separated from the switch. The Smartoptics platform is designed specifically for open line networking. Managed or unmanaged 1U multiplexers that create virtual fibers. They work with any combination of transponders, muxponders and embedded DWDM transceivers. managed DWDM multiplexers combine the simplicity of a passive multiplexer with features usually reserved for complex telco DWDM systems. They have integrated channel monitoring, amplification and signal conditioning and easily handles all of today s data protocols up to 100Gbps per channel all in a plug and play 1U chassis. Embedded DWDM Natvie embedded 10/100G DWDM SAN Connectivity Lower latency Transponders White box switches QSFP28 SR4 distance extension Vendors without DWDM support Muxonders Improved wavelength utilization Native 40G support Transponder Transponder Muxponder handles any combination of embedded DWDM transceivers and transponders for maximum flexibility 3.

Embedded solutions the purest approach to SAN networking Embedded networking is simple and offers significant cost (capex and opex) savings. Because the CWDM/DWDM transceiver is connected directly in the switch, the signal is kept purely optical in the physical layer significantly reducing latency. All the solutions described above are embedded. A CWDM/DWDM signal through a CWDM/DWDM Multiplexer acts in the same way as if it was running over its own fiber pair. This means that none of the features of the switch are lost and no special configurations are required. If a DWDM transponder is used to convert the 850nm client signal to CWDM/DWDM, the switch usually has to be configured in a way that restricts some of the features in the switch. When using an embedded CWDM/DWDM solution, the port works in its default configuration so there s no need for new complex management systems. CWDM/DWDM signals act as if it was running over its own fiber pair, no switch features are lost, no special configurations are required Embedded CWDM/DWDM networking provides the most simple and cost effective method for transporting Fibre Channel over a dark fiber network between data centers. In addition to the commercial benefits, embedded CWDM/DWDM offers a number of technical advantages, compared to more traditional transponder based DWDM solutions. Embedded CWDM/DWDM approach allows: D-Port Testing Electrical loopback test (E-WRAP) Link traffic test Optical loopback test (O-WRAP) Link latency and distance measurement Other Brocade proprietary functions SAN Health Check Encryption FEC ISL Trunking and minimal latency No specific DWDM configurations Transponder systems are overly complex and require switch to be in R_RDY mode. Embedded networking performs as if each wavelength were a virtual fiber. Brocade standard SFP commands can be used functions (sfpshow, portcfgshow, portstatshow). 4.

Approved solutions Single channel connectivity When using Brocade 16G FC switches, Smartoptics offers end-to-end SAN extension solutions qualified and supported at the layer 1 level. If a single channel of 16/10/8G connectivity is required then the transceiver simply connects in to the switch at each site. The line fiber is connected to these transceivers and a single channel connection is established. Distance capabilities 16G FC 40km 8G FC 80km 10GE (VDX) 70km One fiber pair required for every SAN and WAN channel Unmanaged embedded communication Unmanaged embedded solutions are based on a 1U passive CWDM/DWDM multiplexer approach. The CWDM/DWDM transceiver is connected directly in to the switch as per the single channel connectivity solutions but this time it connects into the corresponding channel on the multiplexer instead of directly to the line fiber. Passive multiplexers are simple and cost effective devices that combine up to 8- Brocade ISLs on to a single dark fiber. In this way the capital and operating expenses can be drastically reduced. Embedded CWDM/DWDM systems are simple and cost effective. They drastically reduce fiber operating expenses. Passive multiplexer Passive multiplexer Unmanaged connectivity with CWDM/DWDM transceiver connected directly in to the switch and passive multiplexer Managed embedded networking Should the signals need to be monitored (i.e. laser on/off, send/receive levels, fiber cut, etc), Smartoptics intelligent multiplexer family,, operates in exactly the same plug and play way. Unlike an ordinary passive multiplexer, has a monitoring system that offers a common view of the optical channels. A unique managed passive multiplexer. Managed networking with DWDM transceiver connected directly in to the switch and unique intelligent DWDM multiplexer The world s first intelligent distance extending multiplexer 5.

Managed embedded networking with integrated distance extension Should longer distances be required, has integrated transmit and receive EDFAs (Erbium Doped Fiber Amplifier), dispersion compensation and signal conditioning for point to point connectivity up to 2100 kilometers. It is still the same plug and play experience of a passive multiplexer but with auto traffic commissioning no matter the protocol type. For longer distances, can be set to compensate dispersion on transmit and receive signals Longer distance managed networking can be used as a an inline amplifier to allow for longer distance networking. Each additional inline amplifier increases the span distance by approx. 100 kilometers (dependent on protocol). Inline amplifiers used to increase distance up to 100km between spans. 6.

8G FC solutions Product Part number Brocade models ELWL 40km CWDM 70km CWDM 40km DWDM 0-40km DWDM 0-80km 8G DWDM 0-120km 8G DWDM 0-160km 8G-ER-Dxxx-BR1 8G-ZR-C55-BR1 SO-SFP-8GFC-40D-Cxx 8G-ER-Dxxx-BR1 8G-ZR-Dxxx-BR1 8G-ER-Dxxx-BR1 and M-1601-921936-D003TC1 8G-ER-Dxxx-BR1 and M-1601-921936-D1A3TC1 300, 5100, VA-40FC, 5300, 54XX, 7800, 7840, DCX-4S, DCX 300, 5100, VA-40FC, 5300, 54XX, 7800, 7840, DCX-4S, DCX 300, 5100, VA-40FC, 5300, 54XX, 7800, 7840, DCX-4S, DCX FOS 7.1.1 DCX8510 blades, 6505, 6510, 6520, 7840 DCX8510 blades, 6505, 6510, 6520, 7840 FOS 8.0.2 or higher DCX8510 blades, 6505, 6510, 6520, 7840 DCX8510 blades, 6505, 6510, 6520, 7840 16G FC solutions Product Part number Brocade models ELWL 40km CWDM 0-40km, Channel 1530nm Dxxx = D520 to D610 CWDM 0-40km, Channel 1550nm Dxxx = D260 to D420 DWDM 0-40km 16G DWDM 0-40km 16G DWDM 0-80km 16G DWDM 40-120km 16G-ER-BR2 16G-ER-Dxxx-BR1, 16G-ER-Dxxx-BR2 16G-ER-D340-BR1, 16G-ER-D340-BR2 16G-ER-Dxxx-BR1, 16G-ER-D340-BR2 16G-ER-Dxxx-BR1 and M-1601-921936-D003TC1, 16G-ER-Dxxx-BR2 and M-1601-921936-D003TC1 16G-ER-Dxxx-BR1 and M-1601-921936-D1A3TC1, 16G-ER-Dxxx-BR2 and M-1601-921936-D1A3TC1 16G-ER-Dxxx-BR1 and M-1601-921936-D1B3TC1, 16G-ER-Dxxx-BR2 and M-1601-921936-D1B3TC1 GEN5: DCX8510 blades, 6505, 6510, 6520, 7840 GEN5: DCX8510, FC16-32, DCX8510, FC16-48, 6505, 6510, 6520, 7840 GEN5: DCX8510 blades, 6505, 6510, 6520, 7840 GEN5: DCX8510 blades, 6505, 6510, 6520, 7840 GEN5: DCX8510 blades, 6505, 6510, 6520, 7840 GEN5: DCX8510, FC16-32, DCX8510, FC16-48, 6505, 6510, 6520, 7840 10G approved solutions Product Part number Brocade models CWDM 70km 10G-ZR-Cxx-BR1 VDX 6740, 6940-144S, 8770 NOS v6.01 7.

About Smartoptics Smartoptics offers optical transmission solutions making networks more powerful. Expanding bandwidth without the upfront investment or hassle of traditional WDM. Our products allow corporate data centers, governments, hosting solution providers and ISPs to build simple, straightforward and cost effective solutions to fulfill their ongoing and future network capacity needs. Headquartered in Oslo, Norway, Smartoptics is an international provider with thousands of installations all around the world. Our awardwinning approach has helped companies from every industry sector stay ahead of expanding network demands. Ryensvingen 7 NO-0680 Oslo Norway +47 21 41 74 00 info@smartopics.com smartoptics.com SO-SB-Brocade-approved-R4.1.pdf 8.