PumpDrive. Self -cooling, motor-independent frequency inverter. Brief Instructions

Similar documents
PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

SINUS PENTA 6. ACCESSORIES 6.1. BRAKING RESISTORS APPLICATION TABLES 111/209

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

Accessories for stand-alone gird inverter SMART LOAD 6000

Instruction Manual (Supplementary) Totally-Enclosed Box Type Inverter

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Zenith DS9000 Dispensing System

Siemens Industrial s

User Manual. Solar Inverter for Water Pump

Serial PROFIBUS Interface

TRC-190 User s Manual

BIPOLAR OPERATIONAL POWER SUPPLY

Installation, Operation and Maintenance Manual

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY I INTRODUCTION

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Easy To Use OEMS Take Note

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

MC 11 EB-2 Power supply cabinet with external bus, AC version

MDM 011-Z1 Regen Resistor

Mini Design Inverter. For applications which need tiny installation space. HNC Electric Limited

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

GCI-5K INSTALLATION AND OPERATOR S MANUAL

Hardware Installation. Tracer MP581 Programmable Controller CNT-SVN01C-EN

CDD Carbon Dioxide Transmitter

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Service Instructions. Conductor 420

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II

Instruction Bulletin. ALTIVAR 58 Adjustable Speed Drive Controllers

User Manual. 2.2KW/7.5KW/11KW Solar Inverter for Water Pump. Version: 1.8

VLT 2800 DRIVE SPECIFICATIONS

RXTH DUAL ROOM SENSOR / SWITCH

TCNM-ACBB1 Installation Manual

AI561 Analog Input Module

Hyamaster r SPS. Intelligent single and multiple pump control system with continuous speed control by frequency inverter, with PLC SIMATIC r S7

Operating instructions. Speed monitor D / / 2014

Operating instructions. Switching amplifier DN0210 DN / / 2015

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Installing VO2 Analog Output Boards

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

CPCI-PS24 24V-Power Supply

AF-600 FP TM Fan & Pump Drive. (230V to 60HP, 460/575V to 125HP Operating Instructions

EX-RC1 Remote I/O Adapter

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

RТTH DUAL ROOM SWITCH

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

PowerLogic Circuit Monitor Series 4000T Reference Manual Addendum

High Performance Output Filter Instruction Manual

TRC-190 User s Manual

DI572 Digital Input Module

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVFF

IF-80x Outdoor Terminal

ASI Systems ML5740A Series

ASI Systems ML5720A Series

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

DI561 Digital Input Module

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

Digital encoder interface module 5/12/24 V DANGER

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

CMC III Universal Sensor

Type ME43. Quickstart

DX561 Digital Input/Output Module

Access Terminal IF-800

User's Guide. Model W 3-in-1 Switching DC Power Supply

EX-RC1 Remote I/O Adapter

RXTP ROOM TEMPERATURE

DC562, digital input/output module,

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Rotary version, three-position control

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

V E5B Snap-in I/O Module

Operating Instructions. Power Supply & Latching Relay For Switches Model: RL manual_rl-6000_1016

PDS100 Programmable Dispensing System SAFETY INSTRUCTIONS

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Type Quickstart (from device Version 2)

PTC/PT100 board 2.0 Option

TU531, TU532 Terminal Unit

Manual FC 3500 DC Fan Control

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

AO523 Analog Input Module

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL

Twido Programmable Controllers Discrete I/O Modules

V E62B Snap-in I/O Module

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

AX521 Analog Input/Output Module

Type Quickstart

FREQUENCY CONVERTER FC102 (QUICK GUIDE)

Transcription:

Brief Instructions PumpDrive 4070.801/2--11 Self -cooling, motor-independent frequency inverter Mounting variants: Motor mounting (MM) Wall mounting (WM) Cabinet mounting (CM) Brief Instructions

1 About these instructions Detailed descriptions and instructions for the proper use, maintenance and troubleshooting are available in the PumpDrive operating instructions (4070.81/4). These instructions D form part of the PumpDrive D are brief instructions for immediate use of the PumpDrive D contain descriptions of the following topics: -- Locations -- Connecting cables -- Installation -- Commissioning -- Parameterization 1.1 Warnings and symbols Symbol Meaning Hazard sign " Observe the measures that have a hazard sign in order to avoid injuries and material damage. Information, note " Instructions for actions to be taken Result CAUTION Personal injury and damage to property through unsafe working " Observe the safety instructions (refer to the operating instructions with the number 4070.81/4, Chapter 2, Section 6.4.1). " Always keep the operating instructions available at the site of use. 2

2 Locations The following requirements have to be fulfilled: D well ventilated D no direct sunlight or climatic influences D in case of outdoor mounting protection against condensation water and sunlight D temperature range at pump operation: 0--40 C D in the case of cabinet mounting, two separate copper ground bus bars (mains supply and control connection bar) available 3 Connecting cables 3.1 Power supply cables The following requirements have to be fulfilled: D unshielded (shielding optional) D motor protection switch dimensioned to 1.4 times of rated current D maximum cable cross section (see Table 1, Page 9) 3.2 Control cables The following requirements have to be fulfilled: D shielded cables for the control cables: -- minimum cross--section 0.5 mm 2 -- maximum cross--section terminal strip P4: 0.75 mm 2 -- maximum cross--section terminal strip P7: 1.5 mm 2 D shielded cables for LON and PROFIBUS D minimum distance between control and power cables 0.3 m 3.3 Connecting cable PumpDrive to motor (at stray capacitance Cs < 5 nf) The following requirements have to be fulfilled: D up to 7.5 kw Class B, maximum cable length = 5 m D above 7.5 kw Class A, maximum cable length = 50 m D shielded 3

4 Transport The device must be transported properly and in its original packaging. Prior to dispatch, the device was tested and inspected to ensure full compliance with specifications. Consequently, the device should be in perfect electrical and mechanical condition when received. You are advised to inspect the device for in--transit damage immediately upon receipt. If there are any complaints or objections, the recipient and carrier must jointly draw up a damage report. 4.1 Temporary storage The device must be stored under dry and vibration-free conditions, if possible in its original packaging. The ambient temperature during storage must be between --10 _C and +70 _C. Make sure that the relative humidity does not exceed 85 % and that the electric components are not exposed to condensation (oxidation protection). Avoid major fluctuations in ambient humidity. 4

5 Installation CAUTION Personal injury and damage to property through improper installation " Observe the safety instructions (refer to the operating instructions Chapter 2). " In order to avoid unintentional starting up of the pump: deenergize the motor and secure it against restarting. In the case of the MM mounting variant the PumpDrive is already mounted on a standard motor. " In the case of the WM and CM mounting variants: mount the PumpDrive on the basis of the enclosed mounting instructions to the wall, a mounting frame or in a control cabinet. Variant: MM - mounted on the motor 4070:9014 Fig. 1) Motor--mounted model 5

Variant: WM - mounted on the wall 4070:9013 Fig. 2) Wall--mounted model Variant: CM - mounted in a control cabinet Fig. 3) Cabinet--mounted model 6

6 Installation Damage to property through improper installation CAUTION " Ensure that the power supply cable, the motor connecting cable and control cable are deenergized and are secured against restarting. " Never remove the plastic housing from the metal heat sink. " Only remove the cover as described in the instructions. " Provide for fusing in accordance with the national and local standards and regulations. 6.1 Connecting the motor and power supply cable 1 1 2 Fig. 4) Removing the L--shaped cover " Remove the three crosshead screws 1 on the L--shaped cover 2 and remove the cover (see Fig. 4). 7

1 Fig. 5) Removing the V--shaped cover " Remove the six crosshead screws on the V--shaped cover 1 for the motor and power supply cable and remove the cover (see Fig. 5). Cable compartment accessible for the motor and power supply cable. Fig. 6) Cable compartment for the motor and power supply cable. 8

CAUTION Personal injury and damage to property through improper installation " Do not open or touch the terminals and connectors of the braking resistor (brake). CAUTION Personal injury and damage to property through improper grounding " Do not connect the shielding of the connecting cable to the ground busbar in the control cabinet or to the control ground busbar. " Provide for a shielding of the connecting cable in one piece and ground it at both ends. " Connect the shielding of the control cables to the signal ground. " Determine the size and select suitable cable glands (see Table 1, Page 9). " Depending on the size connect the motor and power supply cable to the terminals in the cable compartment at the PumpDrive (see Fig. 7, Fig. 8, Fig. 9). Size Power Cable gland for Input cur- Max. PumpDrive [kw] rent 1) cable Power - Sensorcable cable thermi- section Motor PTC [A] cross - supply cable stor [mm 2 ].. 000K55.. 0.55 1.9.. 000K55.. 0.75 2.6 A.. 001K10.. 1.1 3.7 M25 M16 M25 M16.. 001K50.. 1.5 5 2.5.. 002K20.. 2.2 6.3.. 001K10.. 3 8.5.. 004K00.. 4 10.5 B.. 005K50.. 5.5 M25 M16 M25 M16 13.7 2.5.. 007K50.. 7.5 17.3.. 011K00.. 11 26.5 C.. 015K00.. 15 32.6 M32 M16 M32 M16.. 018K50.. 18.5 41 10.. 022K00.. 22 47.3.. 030K00.. 30 68.3 D.. 037K00.. 37 M40 M16 M40 M16 84 35.. 045K00.. 45 97.7 Table 1) Cable glands for the motor and power supply cable 1) Note the information on the use of line reactors (refer to operating instructions, Accessories and optional equipment under Line reactors. 9

Sensor & PTC sensor Analog input 2 +24VIN 0 PTC thermistor PE L1 L2 L3 1 2 3 4 5 6 U V W Brake L1 L2 L3 N PE Fig. 7) M 3~ Power supply and motor wiring for Sizes A & B Sensor & PTC sensor Analog input 2 +24VIN 0 PTC thermistor PE L1 L2 L3 U V W 1 2 3 4 5 6 Brake L1 L2 L3 N PE Fig. 8) M 3~ Power supply and motor wiring Size C 10

Sensor & PTC sensor Analog input 2 +24VIN 0 PTC thermistor 1 2 3 4 5 6 PE L1 L2 L3 U V W Brake Fig. 9) L1 L2 L3 N PE Power supply and motor wiring Size D M 3~ 11

6.2 Connecting control cables CAUTION Damage to property through improper removal of the control panel " When removing the control panel: use a slotted screwdriver as a lever at the upper end. 1 1 Fig. 10) Control panel fastening " Unscrew the crosshead screws 1 on the control panel and remove the control panel (see Fig. 10). The terminal strips P4 and P7 are located under the control panel (see Fig. 11). 1 2 Fig. 11) Position of the terminal strips P4 and P7 1) Terminal strip P4 2) Terminal strip P7 12

" Connect the control cables. Observe the control terminal assignment: -- P4 (see Table 2) -- P7 (see Table 3) Terminal No. Signal Description 20 0V Ground for +24 V 19 DIG IN6 Digital-input (15/28 VDC) 18 DIG--IN5 Digital-input (15/28 VDC) 17 DIG--IN4 Digital-input (15/28 VDC) 16 DIG--IN3 Digital-input (15/28 VDC) 15 DIG--IN2 Digital-input (15/28 VDC) 14 DIG--IN1 Digital-input (15/28 VDC) 13 +24 V +24 VDC-voltage supply Max. load 200 ma 12 0V--AN Ground for AN OUT 11 AN OUT Analog output 0--10V. Max. load 5 ma 10 SB1--GND Ground for KSB local bus 9 SB1 + KSB local bus signal 8 SB1 -- KSB local bus signal 7 PE (GROUND) Ground 6 PE (GROUND) Ground 5 SB1--GND Ground for KSB-local-bus 4 SB1 + KSB local bus signal 3 SB1 -- KSB local bus signal 2 SB1Z-- Bus terminating element for KSB-local-bus 1 SB1Z+ Bus terminating element for KSB-local-bus Table 2) Pin assignment of terminal strip P4 Terminal No. Signal Description 10 0V--AN Ground for AIN1/2 9 AN1--IN Programmable Analog-Input 1 Factory setting: setpoint source 0--10 V or 0--20 ma 8 PE (GROUND) Ground 7 0V Ground for +24 V 6 AN2--IN Programmable Analog-Input 2 Factory setting: Actual value source 0--10 V or 0--20 ma 5 +24 V +24 VDC-voltage source (max. 200 ma load) 4 NO2 NO contact NO No. 2 (250 VAC, 1A) 3 COM2 NO contact COM No. 2 (250 VAC, 1A) 2 NO1 NO contact NO No. 1 (250 VAC, 1A) 1 COM1 NO contact COM No. 1 (250 VAC, 1A) Table 3) Pin assignment of terminal strip P7 13

7 Commissioning All the settings at the PumpDrive are carried out in parameters. Each parameter has a unique four--digit number. Parameters can only be set by using a graphics control panel. 7.1 Operation Fig. 12) Graphics control panel Fig. 13) Parameter 3--2--1--3 (example) Proceed as follows in order to set parameters with the graphics control panel: " Enter the first digit by means of the four yellow buttons on the control panel. The four buttons stand for the Digits 1--4 (see Fig. 12). " For all the further digits press the Up/Down buttons of the control panel until the digit of the parameter is displayed in the upper left--hand corner and confirmed with OK (see Fig. 13). " Use ESC to return to the previous digit. 14

7.2 Parameterizing the PumpDrive PumpDrive can be used for different application cases. " Depending on the operating mode and the design, select the chapter from the following table. Operating mode Open -loop control: Setpoint specification internal Setpoint specification external Closed -loop control: Setpoint specification internal Setpoint specification external PumpDrive design without control panel with control panel (only single -pump configuration) Section 7.2.1, Page 15 Section 7.2.3, Page 16 Section 7.2.1, Page 15 Section 7.2.4, Page 16 (single - or multiple -pump configuration) Section 7.2.2, Page 16 Section 7.2.5, Page 17 Section 7.2.2, Page 16 Section 7.2.6, Page 17 7.2.1 Without control panel - Open -loop control - Setpoint specification internal/external The PumpDrive PC software can be used to parameterize PumpDrive if you do not have access to a control panel: -- Use the service interface to connect a PC/Notebook via a special connecting cable (miniusb--rs232). -- Start the PumpDrive PC software. -- Parameterize as with the control panel (see Section 7.2.4, Page 16). " For only one setpoint signal between 0 V and 10 V: connect the setpoint signal to the terminal strip P7 at Analog Input 1. " Set the motor data (see Section 7.3, Page 20). 15

7.2.2 Without control panel - Closed -loop control - Setpoint specification internal/external The PumpDrive PC software can be used to parameterize PumpDrive if you do not have access to a control panel: -- Use the service interface to connect a PC/Notebook via a special connecting cable (miniusb--rs232). -- Start the PumpDrive PC software. -- Parameterize as with the control panel (see Section 7.2.4, Page 16). " For only one setpoint signal between 0 V and 10 V: connect the setpoint signal to the terminal strip P7 at Analog Input 1. " For one actual value signal between 4 ma and 20 ma: connect the actual value signal to the terminal strip P7 at Analog Input 2. " Set the motor data (see Section 7.3, Page 20). 7.2.3 With control panel - Open -loop control - Setpoint specification internal " At graphics control panel: -- Select the parameter 3-5-4-2 and set Menu Item 4 (factory setting). -- Set the setpoint by using the parameter 3-5-2-1. " If the lower and upper setpoint deviate from the factory settings 0% and 100%: Set the minimum and maximum setpoints: -- Set the minimum setpoint by using the parameter 3-5-1-2. -- Set the maximum setpoint by using the parameter 3-5-1-3. " At a standard control panel: -- Use the arrow buttons to change to the setpoint value display (green LEDs and confirm with OK. -- Use the arrow buttons to set the setpoint (increment = 0.25 Hz or 0.5%) and confirm with OK. " Set the motor data (see Section 7.3, Page 20). 7.2.4 With control panel - Open -loop control - Setpoint specification external " For only one setpoint signal between 0 V and 10 V: connect the setpoint signal to the terminal strip P7 at Analog Input 1. " If the setpoint signal does not lie between 0 V and 10 V or if more than setpoint signal is to be used: see Section 7.2.7, Page 18 " Set the motor data (see Section 7.3, Page 20). 16

7.2.5 With control panel - Closed -loop control - Setpoint specification internal " Parameterize the source of the setpoint at the control panel: -- Set the setpoint source. To do so, select the parameter 3-5-4-1and set Menu Item 4 (factory setting). -- Set the setpoint by using the parameter 3-5-2-1. " For one actual value signal between 4 ma and 20 ma: connect the actual value signal to the terminal strip P7 at Analog Input 2. " If the actual value signal does not lie between 4 ma and 20 ma: see Section 7.2.8, Page 19 " Set the motor data (see Section 7.3, Page 20). 7.2.6 With control panel - Closed -loop control - Setpoint specification external " For only one setpoint signal between 0 V and 10 V: connect the setpoint signal to the terminal strip P7 at Analog Input 1. " If the setpoint signal does not lie between 0 V and 10 V or if more than setpoint signal is to be used: see Section 7.2.7, Page 18 " For one actual value signal between 4 ma and 20 ma: connect the actual value signal to the terminal strip P7 at Analog Input 2. " If the actual value signal does not lie between 4 ma and 20 ma: see Section 7.2.8, Page 19 " Set the motor data (see Section 7.3, Page 20). 17

7.2.7 Setting the source for the setpoint signal Setpoint sources can only be parameterized with a graphic control panel. A maximum of 3 sources for setpoints can be set. " Set the sources for the setpoints (see Table 4, Page 18). " If the setpoint signal does not lie between 0 V and 10 V: -- Parameterize the source for the setpoint (refer to the operating instructions Section 8.3.1, Table 23). -- If Analog Input 1 is set as the source for the setpoint (factory setting): Parameterize Analog Input 1 (refer to the operating instructions Section 8.3.2, Table 25). -- If Analog Input 2 is set as the source for the setpoint: Parameterize Analog Input 2 (refer to the operating instructions Section 8.4.2, Table 33). Parameter Description Setting range/options 3--5--4--1 Source setpoint signal 1 1, 2, 3, 4, 5, 6 3--5--4--2 Source setpoint signal 2 1, 2, 3, 4, 5, 6 3--5--4--3 Source setpoint signal 3 1, 2, 3, 4, 5, 6 Table 4) 1Nosource 2 Analog Input 1 3 Analog Input 2 4 Adjustable setpoint 5 Setpoint field bus 6 RS232 -- setpoint Sources for setpoint 18

7.2.8 Setting the source for the actual value signal The actual value signal can be read in from 7 different sources. " Set the actual value signal (see Table 5, Page19). " If the actual value signal does not lie between 4 ma and 20 ma: Parameterize the actual value source (refer to the operating instructions Section 8.4.2, Table 33). Parameter Description Setting range/options 3--9--2--1 Source actual value signal 1, 2, 3, 4, 5, 6 1 Table 5) 1 Analog Input 1 2 Analog Input 2 3 DIFF (AI1, AI2) 4 MIN (AI1, AI2) 5 MAX (AI1, AI2) 6 AVE (AI1, AI2) 7 Rem actual value Sources for actual value 19

7.3 Setting the motor data " Call up the following parameters and set the appropriate values for the motor (refer to the operating instructions, Section 8.1): Parameter Description Setting range/options 3--3--2--1 Rated power 0.55.0.110 [kw] 3--3--2--2 Rated voltage 342..528 [V] 3--3--2--3 Rated frequency 45..65 [Hz] 3--3--2--4 Rated current 0,1..999 [A] 3--3--2--5 Rated speed 300... 3600 [1/min] 3--3--2--6 Nominal cos. phi 3--3--5--1 PTC thermistor On/off 3--6--1--1 Direction of rotation of motor Table 6) Setting the motor data " Check the direction of rotation (see Section 7.4). Clockwise/ Counterclockwise 7.4 Checking the direction of rotation " If a control panel is available: Press the Man button on the control panel. The drive is operated with the lower limit of the motor frequency. " If no control panel is available: Connect a voltage of 24 V to Digital Input 1. " If the direction of rotation is incorrect: Interchange two phases of the motor or Select the parameter 3-6-1-1 and set the value to Counterclockwise. " Operate the pump aggregate (see Section 7.5). 7.5 Operating " Start with Digital Input 1 (Terminal 4:14 Signal +24 VDC). 20

21

22 PumpDrive

23

4070.801/02--11 26.04.2007 We reserve the right to make technical changes. KSB Aktiengesellschaft 67225 Frankenthal Johann-Klein-Str. 9 67227 Frankenthal (Germany) Tel. +49 (0)6233 86-0 Fax +49 6233 86-3401 www.ksb.de