THE WIRELESS PHANTOM PERFORM ACCURATE PATIENT QA IN LESS TIME THAN EVER!

Similar documents
Delta 4 PT. True Volumetric Pre-treatment Verification. The difference is clear

Raising the Bar in IMRT QA

MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays

MapCHECK 2 & 3DVH. The Gold Standard for 2D Arrays

IMRT and VMAT Patient Specific QA Using 2D and 3D Detector Arrays

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE

FAST, precise. qa software

ADVANCING CANCER TREATMENT

Volumetric Modulated Arc Therapy - Clinical Implementation. Outline. Acknowledgement. History of VMAT. IMAT Basics of IMAT

ADVANCING CANCER TREATMENT

Facility Questionnaire PART I (General Information for 3DCRT and IMRT)

DAILY LINAC QA BEAM QA

Evaluation of 3D Gamma index calculation implemented in two commercial dosimetry systems

Tomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS

Code of practice: Create a verification plan for OCTAVIUS Detector 729 in Philips Pinnacle³

3D Scanning Comes Full Circle

3DVH : SUN NUCLEAR On The Accuracy Of The corporation Planned Dose Perturbation Algorithm Your Most Valuable QA and Dosimetry Tools *Patent Pending

8/2/2017. PerFRACTION from Sun Nuclear Automated Transit Dosimetry for In-Vivo QA

Real-time monitoring of linac performance using RT plans and logfiles

ph fax Deming Way Middleton WI USA

Table of Contents. About AQUA

A comparative analysis for verification of IMRT and VMAT treatment plans using a 2-D and 3-D diode array

Quality assurance of a helical tomotherapy machine

Initial Clinical Experience with 3D Surface Image Guidance

Hugues Mailleux Medical Physics Department Institut Paoli-Calmettes Marseille France. Sunday 17 July 2016

Qalitätssicherung an Multileafkollimatoren. Dr. Lutz Müller Würzburg jan 2004

7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT

Dynalog data tool for IMRT plan verification

3DVH FAQs. What is PDP questions

Goals. Scope/exclusions. Outline: follow outline of MPPG (plus rationale & some implementation experiences)

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

IAEA-TECDOC-1583 Commissioning of Radiotherapy Treatment Planning Systems: Testing for Typical External Beam Treatment Techniques

Radiotherapy Plan Competition TomoTherapy Planning System. Dmytro Synchuk. Ukrainian Center of TomoTherapy, Kirovograd, Ukraine

Digital Imaging and Communications in Medicine (DICOM) Supplement 176: Second Generation Radiotherapy. Additional RT Treatment Modalities

Using a research real-time control interface to go beyond dynamic MLC tracking

8/4/2016. Emerging Linac based SRS/SBRT Technologies with Modulated Arc Delivery. Disclosure. Introduction: Treatment delivery techniques

4 Measurement. and Analysis. 4.1 Overview and Underlying Principles 4-1

The MSKCC Approach to IMRT. Outline

Acknowledgments. Ping Xia, Ph.D., UCSF. Pam Akazawa, CMD, UCSF. Cynthia Chuang, Ph.D., UCSF

Machine and Physics Data Guide

Position accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon

Clinical implementation of photon beam flatness measurements to verify beam quality

Feasibility of 3D Printed Patient specific Phantoms for IMRT QA and Other Dosimetric Special Procedures

Oncentra Brachy. Anatomy-based treatment planning for HDR/PDR brachytherapy

Accuracy study. Elekta Synergy S. High precision radiation therapy using Elekta Synergy S. UMC, Utrecht, Netherlands. Institution: Purpose:

Integrated proton-photon treatment planning

A secondary monitor unit calculation algorithm using superposition of symmetric, open fields for IMRT plans

Analysis of Radiation Transport through Multileaf Collimators Using BEAMnrc Code

Digital Imaging and Communications in Medicine (DICOM) Supplement 176: Second Generation Radiotherapy. Additional RT Treatment Modalities

Calibration and quality assurance for rounded leaf-end MLC systems

Monaco VMAT. The Next Generation in IMRT/VMAT Planning. Paulo Mathias Customer Support TPS Application

INNOVATIVE LASER POSITIONING SOLUTIONS IN RADIATION ONCOLOGY.

ViewRay System Commissioning

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC

URGENT IMPORTANT FIELD SAFETY NOTIFICATION

3D SCANNER. 3D Scanning Comes Full Circle. Your Most Valuable QA and Dosimetry Tools

Measurement of depth-dose of linear accelerator and simulation by use of Geant4 computer code

Data. ModuLeaf Mini Multileaf Collimator Precision Beam Shaping for Advanced Radiotherapy

Advanced Radiotherapy

TEPZZ Z754_7A_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (51) Int Cl.: A61N 5/10 ( )

TG-148 overview. Introduction. System Overview. System Overview. QA for Helical Tomotherapy: Report of the AAPM Task Group 148. Conflict of Interest:

VMAT for dummies: Concepts, Clinical Implementation and Treatment Planning. Rajat Kudchadker, Ph.D. Associate Professor

Digital Imaging and Communications in Medicine (DICOM) Supplement 176: Second Generation Radiotherapy. Additional RT Treatment Modalities

Virtual Phantoms for IGRT QA

TOMOHD. Product Specifications

Dose Distributions. Purpose. Isodose distributions. To familiarize the resident with dose distributions and the factors that affect them

Computational modelling and analysis: IOP Medical Physics Group

Image Guidance and Beam Level Imaging in Digital Linacs

Version 3.7. User Manual

Evaluation of detector array technology for the verification of advanced intensity-modulated radiotherapy

IHE Radiation Oncology Technical Framework Supplement. Treatment Delivery Plan Content (TDPC) Rev. 1.1 Trial Implementation

Basic Radiation Oncology Physics

Comparison of MLC error sensitivity of various commercial devices for VMAT pre-treatment quality assurance

COMPARISON OF DOSE CALCULATION ALGORITHMS FOR LEKSELL GAMMA KNIFE PERFEXION USING MONTE CARLO VOXEL PHANTOMS

1. Learn to incorporate QA for surface imaging

Comparison of 3D and 2D gamma passing rate criteria for detection sensitivity to IMRT delivery errors

The Dose Junction Issue Associated with Photon Beams for Large Volume Radiation Therapy and the Sensitivity to Set-up Error

Quick Reference Datasheet For All RIT113 Packages

Use of a commercial ion chamber detector array for the measurement of high spatial resolution photon beam profiles

Disclosure. Outline. Acknowledgments. Ping Xia, Ph.D., Page 1. LINAC and MLC QA for IMRT. Received research support from Siemens Medical Solutions

MRI-LINAC Dynamic Phantom

ImPACT. Information Leaflet No. 1: CT Scanner Acceptance Testing

Beams You Up to a New Era in 3D Water Scanning.

Medical Dosimetry 37 (2012) Medical Dosimetry. journal homepage:

NEW METHOD OF COLLECTING OUTPUT FACTORS FOR COMMISSIONING LINEAR ACCELERATORS WITH SPECIAL EMPHASIS

A SYSTEM OF DOSIMETRIC CALCULATIONS

Dosimetric Analysis Report

URGENT IMPORTANT FIELD SAFETY NOTIFICATION

Anthropomorphic Verification of the Eclipse AAA Algorithm for Spine SBRT Treatments Involving Titanium Implants

Feasibility study of performing IGRT system daily QA using a commercial QA device

Lucy Phantom MR Grid Evaluation

Protocol. Technical evaluation of X-ray tomographic image-guided radiotherapy devices CEP10070

LUP. Lund University Publications. Institutional Repository of Lund University

IMRT site-specific procedure: Prostate (CHHiP)

PROVEN TECHNOLOGY IMPROVED

Photon beam dose distributions in 2D

Geant4 in Brachytherapy

REF User Manual DOC # STANDARD IMAGING, INC Deming Way Middleton, WI

Use of Monte Carlo modelling in radiotherapy linac design. David Roberts, PhD Senior Physicist Elekta

The use of an on-board MV imager for plan verification of intensity modulated radiation therapy and volumetrically modulated arc therapy

Transcription:

THE WIRELESS PHANTOM PERFORM ACCURATE PATIENT QA IN LESS TIME THAN EVER!

Confidence in complex treatments Modern radiation therapy uses complex plans with techniques such as IMRT, VMAT and Tomotherapy. A single plan can consist of more than a hundred control points and include MLC leaf movements, gantry and collimator angle rotations etc. in order to produce steep dose gradients within the patient. To keep up with increasing complexity, a thorough verification of treatment plans is paramount for clinics to treat each patient with confidence and accuracy. For this purpose it is necessary to independently verify: - The TPS dose. - The transfer of data from TPS to the delivery system. - The performance of the delivery system. - The relationship of the delivered dose to the target and OAR s.

Fast and accurate QA with Delta 4 Phantom+ The new wireless Delta 4 Phantom+ provides fast and accurate dose verification for your advanced treatment plans. Fast set-up. The phantom is easily transferred to the treatment couch with the Delta 4 Trolley. You never have to lift the phantom! Alignment is easily done in seconds with clear markers on the phantom that allow you to accurately position the Delta 4 Phantom+ in 6 dimensions. Instantly ready for measurement. The Delta 4 Phantom+ transfers data via Wi-Fi and it is battery powered. There are no cable connections. Just turn on the power and you are ready to measure. Measure where it really matters. The patented detector configuration with two orthogonal detector planes provides real measurements in the isocentric target region. Instant pass/fail analysis. Since measurements are made in the target, the relevant dose is instantly available when the irradiation has been delivered. The delivered dose is instantly compared with the planned dose and analyzed against your pass/fail criteria. Independent Gantry angle verification. An inclinometer gives you independent verification that the beams are delivered from the right angles. Machine QA. In addition to patient QA the Delta 4 Phantom+ can perform checks of the beam constancy and the MLC performance.

Next generation technology Unique detector configuration Isocentric measurements in two orthogonal detector planes Merge large fields up to 38 cm longitudinal Resolution 5 mm at isocenter, can be increased to 2.5 by merging Wireless Fastest set-up time Wireless communication (Wi-Fi) Battery operated Quick and easy set-up The ergonomic Delta 4 Phantom+ Trolley eliminates all lifting when transferring the phantom from the Trolley to the couch. The set-up and alignment of the phantom is done within seconds. Furthermore, the Trolley serves as a neat and compact roll-and-store platform for the phantom.

that works for your benefit Superior ScandiDos detector: Long term stable, detectors, eliminates re-calibration of relative sensitivity Isotropic response FFF compatible Easy levelling Levelling with 3 or 4 point adjustment Absolute measurement Quick and accurate absolute dose verification Ion chamber measurements can also be performed in the same phantom

Intuitive and loaded with analysis tools Integrated in the workflow The Delta 4 software is known for its integration in the clinical workflow. TPS plans are easily imported together with TPS dose and structures. Intuitive The genuinely intuitive software decreases your learning curve. You can easily navigate between patients, measurements and analysis and all the information you need is just a click away. The QA analysis is performed automatically as soon as the dose has been delivered instantly indicating pass or fail. Instant Your QA results, including dose deviation, distance to agreement (DTA) and gamma index, are instantly available without any further processing and QA reports are easily customized to your specific needs. Powerful analysis With unique 4D measurements you also have the data to analyze the delivered dose for fraction, beam arc or control point. The delivered 4D dose can also be analyzed in the patient anatomy. The Delta 4DVH suite of software modules provides unique analysis tools to find the clinical significance of a deviation.

Technical specification Cylinder phantom Detectors Material PMMA; optional Plastic Water DT Diameter Length 22 cm 40 cm Ion chamber insert in cylinder Inserts for common cylindrical ion chambers available Type p-si Total number 1069 Layout Max field size Distance between detectors Central area (6 x 6cm 2 ) Outer area Distributed on coronal and sagittal plane 20 x 38 cm 2 (with merger of two consecutive measurements, otherwise 20 x 20 cm 2 ) 5 mm (or 2.5mm in longitudinal direction with merger of two consecutive measurements) 10 mm Size (radial x axial) 1 x 0.05 mm 3 = 0,00004 cm 3 Detector stability (6MV beam) Better than 0.1% per kgy, typically 0.04%/kGy Size and weight Total length Total weight Compatibility Modalities Treatment Plan import 71cm 27kg Photon beams, with and without flattening filter Any Treatment Planning system that can export DICOM RT Plan and RT Dose, Structure Wireless Communication Wireless data communication protocol Wi-Fi 802.11n Battery operational capacity >4 hours Rechargeable Li-ion battery Power supply for charging included Technical specifications are subject to change without notice

D017 03 001 03 ScandiDos is an innovative, cutting edge developer and manufacturer of quality assurance solutions and a world innovations for precise Qa from plan to the last fraction leader in dosimetry for radiation therapy. By developing tools for efficient QA, we help to make new and improved treatment techniques available. ScandiDos strives to be at the forefront of technology development to enable First: 3D Pre Treatment Verification System modalities. 4D Dose measurement and analysis system 6D Motion Management QA system for more information. At Treatment Verification for VMAT and IMRT the rapid clinical adoption of the latest treatment Contact us today, or visit www.scandidos.com Delta 4 and ScandiDos are registered trademarks of ScandiDos AB TM Delta 4 Discover is a trademark of ScandiDos AB Plastic Delta Water 4 and DT ScandiDos is a registered are trademark registered of trademarks Computerized of ScandiDos Imaging AB. Reference Systems, Inc (CIRS) Headquarter ScandiDos AB (Publ). Uppsala Science Park, SE-751 83 Uppsala, Sweden Tel +46 (0)18-472 30 30 www.scandidos.com Info@ScandiDos.com US Office USA ScandiDos Inc. Madison, WI, USA China China Beijing ScandiDos Technology Ltd. Co. Beijing, P.R. China France ScandiDos SAS Paris, France