High Density Cooling Solutions that work from Knurr Kris Holla

Similar documents
Rack & Enclosure Systems

MSYS 4480 AC Systems Winter 2015

ECOBAY: Closed loop water cooled server cabinet for data centers

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Next Generation Cooling

IT infrastructure Next level for data center. Rittal The System Yavor Panayotov Data center Day

Close Coupled Cooling for Datacentres

Reducing Data Center Cooling Costs through Airflow Containment

Liebert DCW CATALOGUE

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

Enabling Business Critical Continuity for Unified Communications. Andy Liu Product Manager, Asia Pacific

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Close-coupled cooling

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

HIGH DENSITY RACK COOLING CHOICES

LCP Hybrid Efficient performance with heat pipe technology

SmartAisle. SmartAisleTM. Energy-efficient use of existing cooling power in data centers to

Power and Cooling for Ultra-High Density Racks and Blade Servers

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

Energy Efficient Data Centers

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER

Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer

Efficiency of Data Center cooling

HPC Solutions in High Density Data Centers

BENEFITS OF ASETEK LIQUID COOLING FOR DATA CENTERS

Data Center Trends and Challenges

18 th National Award for Excellence in Energy Management. July 27, 2017

Investor day. November 17, IT business Laurent Vernerey Executive Vice President

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

Planning for Liquid Cooling Patrick McGinn Product Manager, Rack DCLC

Total Modular Data Centre Solutions

LCS Value Proposition November 2014

High Efficient Data Center Cooling

DATA CENTER LIQUID COOLING

Rittal LCP T3+ High-availability IT cooling with no compromise

Rittal Cooling Solutions A. Tropp

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Green Data Centers A Guideline

NREL Validates LCS Technology. PRESENTED BY Herb Zien CEO, LiquidCool Solutions

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Recapture Capacity for Existing. and Airflow Optimization

Making the impossible data center a reality.

Product Guide. Direct Contact Liquid Cooling Industry leading data center solutions for HPC, Cloud and Enterprise markets.

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

SmartAisle Intelligent, Integrated Infrastructure Using Row-based Building Blocks. Solutions For Business-Critical Continuity

Switch to Perfection

Perfect Cooling. A perfect climate for high performance servers

Effectiveness and Implementation of Modular Containment in Existing Data Centers

) ) page 04. page 07. page 10. page 10. page 12. page 14. page 14. page 16. page 18. page 19. page 19. page 20. page 21. page 22

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Power & Cooling Considerations for Virtualized Environments

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired

Liquid Cooling Package LCP Cooling Systems

Systems and Technology Group. IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development

How to Increase Data Center Efficiency

100% Warm-Water Cooling with CoolMUC-3

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Precision Cooling. Precision Cooling Advantages

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

Virtualization and consolidation

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

TWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months

Data Center Airflow Management Basics: Comparing Containment Systems

Planning a Green Datacenter

The Evolving Data Center

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

Green IT and Green DC

One Stop Cooling Solution. Ben Tam Business Development Manager

Brad Nacke Enterprise Account Leader Data Centers

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Scale out Server

What s New for Data Centers in Title Jeff Stein, PE Taylor Engineering

Highly Efficient Power Protection for High Density Computing Applications

Critical Facilities Round Table SUN Microsystems Friday, March 25, Thursday, March 24, 2005 Wright Line LLC,

Smart Solutions Intelligent, Integrated Infrastructure for the Data Center

ANCIS I N C O R P O R A T E D

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Water-Cooling and its Impact on Performance and TCO

DATA CENTER AIR HANDLING COOLING SOLUTIONS

Introducing the Heat Wheel to the Data Center

How High-Density Colocation and Enhanced Visibility Improve Business Performance

Creating an Energy-Efficient, Automated Monitoring System for Temperature and Humidity at a World-Class Data Center

Experimental Study of Airflow Designs for Data Centers

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node

ENCLOSURE HEAT DISSIPATION

Liebert XD. Cooling Solutions For High Heat Density Applications. Precision Cooling For Business-Critical Continuity

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

The TeliaSonera Green Room Concept for high and mid density ICT equipment

M+W Group s Visionary Delta Datacenter

High Tech Getting Too Hot? High Density Environments Require A Different Cooling Approach

Application of Green Technology For Data Centre

84 kw, Tier 3, Direct Expansion, 937 ft 2

Transcription:

High Density Cooling Solutions that work from Knurr Kris Holla The Heat Goes On Ó by

Knürr A An International Company Ranked #3 in the world Founded 1931 Strong international setting in over 32 countries Engineering & Manufacturing in Europe, Americas, Asia ~ 1.200 employees worldwide Focus on Telecom, LAN/Networking, Server/Storage, Data Centers, Traffic/Automotive, Medical Equipment, Security Portfolio of leading global customers Ó by

Knurr- Third largest Enclosure company in the world Our Products and Sevices... Rack and enclosure systems + technical furniture Customized solutions & standard products - platform based Level 3 system integration: Mechanics cabling thermal power active components Innovation quality/reliability flexibility speed attractive price Ó by

Leader in Networking & Data Center Products Serverracks Cooling Power Supply DI-Strip UPS Cable Management Administration TFT Displays KVM Switches Security RMS @-lock Ó by

Today we focus on High Density cooling Solutions Contents Capabilities of Liquid Cooling («LC») Water the Domesticated «Beast» - Rack Liquid Cooling GridKa: The World First Completely Watercooled Cluster- A case Study TCO Study Total Cost of Ownership Ó by

Can You Pack This into a Serverrack? This is our dilemma today... 37 Pizzas: å 12 kw 5 7U Blade Boxes: å 18 kw Ó by

Yes You can...... there is enough space in a 42 U Rack! Ó by

But: Can You Cool It? May be if there is enough cold air around it! Ó by

Can You Put It Into This Environment? You can but you cannot cool it! Ó by

The Limits of Air Cooling - High end datacenters today accommodate only. [HP] Maximum heat load : ~ 1.100 1.500 W/m² (100-140 W/sqft) = 3-4 kw / rack Ó by

Is This the Solution? 3,6 kw / rack 4 kw / rack Leave your racks empty? Build new datacenters? Ó by

Today The Room is also the Limit [Siemens Business Services] You cannot unleash a hurricane in a room But you can box it in a rack! Ó by

It's All About bringing the Cold closer to the Heat - Bring cooling to Enclosure level.not room Rack Liquid Cooling Ó by CPU Liquid Cooling

High Density Cooling Solutions that Work-Cooltherm Rack Liquid Cooling Miracel CoolTherm CoolTherm Ó by

CoolTherm: Basic Function cooling water connection Ó by

The need to Shift to a new approach-water Comes Back...Capabilities of Liquid Cooling (1,000 Watt, DT = 10 C / 18 F) x 3.500! Heat transport ða small water tube can carry more heat than an entire room of air! In other words the amount of heat that can be removed by water is roughly 3,500 times which can be removed by the same volume of air. Security Water has been a standard and safe medium for heat transport in buildings and mainframes for decades. Flexibility Fluid cooling systems can be flexibly adapted to new cooling needs in the datacenter. Ó by

CoolTherm - Performance Data 10 22 kw cooling capacity height up to 54 U / 2600 mm / 102" width 700 or 800 mm / 28 or 32" depth 1.200 or 1.300 mm / 48 or 52" 6 or 9U air/water heat exchanger cooling water temp. 12 / 18 C (54/65 F) 0.4 0.9 l/s (6-14 USgal/min) water flow ~ 0.3 bar (4 PSI) pressure drop system pressure ~ 2 3 bar (30-45 PSI) closed air loop 2000 5500 m³/h (1,200-3,250 cfm) air flow cooling air temp. 20 25 C (68-77 F) Þ ASHRAE Class 1 recommended envelope Ó by

CoolTherm - Main Advantages. ~ 0 heat disspation to the room uniform cooling air temperature over height, enhanced component lifetime for any 19" components water strictly under server compartment 2 or 3 fans / n+1 redundancy cooling control by fan speed monitoring of temperatures, water flow, fan speed, fire detection by RMS low noise emission enhanced protection against smoke, water vapor, high temperature in case of fire Ó by

Ultimate Cooling: CoolTherm 22 kw-25kw Ó by

Miracel Cooltherm- Closed loop Cooling Benefits... Improved Cooling More Data Processing Dense Packing Sealed System Smoke Sensing Lower Noise levels Improved work areas Fully Monitored In a Nutshell--They are Reliable, Very Economical with Highest performance and Secured.. Ó by

The Case Study Project Ó by

GridKa: Computing Power for High Energy Physics Pictures/Data: Forschungszentrum Karlsruhe Ó by

GridKa: Data Challenge and Hardware Deployment Pictures/Data: Forschungszentrum Karlsruhe Ó by

Rack Liquid Cooling for Cluster Computing 4 kw/rack 12-15 kw/rack Pictures/Data: Forschungszentrum Karlsruhe Ó by

GridKa Milestones 2001: Forschungszentrum Karlsruhe starts deployment of a new grid data center «GridKa» Oct 2002: Prototype of world first completely watercooled PC cluster goes into operation Mar 2003: - multiple watercooled server- / storage-racks operating - 780 CPUs, 160 TB RAID, 250 TB tape - several hundreds kw cooling capacity (watercooled) Oct 2003 - more then 60 racks installed - Extension to > 80 racks / ~ 1 MW scheduled for Q1/05 Pictures/Data: Forschungszentrum Karlsruhe - on only 250 m² (2,700 sqft) room size Ó by

Rack Liquid Cooling: System Installation Pictures/Data: Forschungszentrum Karlsruhe 1 MW ó Æ 125 mm / 5 Ó by

Full Density: Liquid Cooled 12kW Racks / 1 MW (ultimate configuration) on 250m² / 2,700 sqft The worlds first completely watercooled operating cluster - since 2002 Result: Reduction of 240 Racks to 60 Pictures/Data: Racks Forschungszentrum Karlsruhe and Reduction of Floor Space from 10000 Sqft to 2500 Sqft. Ó by

Economy Ó by

TCO Study by DS-Plan Virtual Model Data Center: - 2000 1U servers ("pizzabox") - 500 W heat dissipation each - 1 MW in total Removal of heat load by: Option1: Conventional Airconditioning Option 2: Rack Liquid Cooling (Knürr CoolTherm) Ó by

Main Impact on Investment: 80% Floor Space Reduction Option1: Conventional Airconditioning - 4 kw / rack - 8 servers / rack - 250 racks - 750 m² floor space - 4,5 m room height Option 2: Rack Liquid Cooling (Knürr CoolTherm) - 20 kw / rack - 40 servers / rack - 50 racks - 150 m² floor space - 3,5 m room height Ó by

TCO Study: Investment Cost Investment Costs for Data Center Example ] Investment costs [1.000 2500 2000-40 % Electric equipment Ventilation 1500 Refrigeration Racks 1000 Required space 500 0 Conventional Airconditioning Rack Liquid Cooling (CoolTherm) Ó by Please Pleasenote note green bar green barisis removed. removed.

TCO Study: Energy Cost Electricity Costs for Data Center Example (without Servers) 90-15 % /a] Electricity cost [1.000 100 80 70 Recooling plant Compression chillers Racks Recirculated air DC 60 50 40 30 20 10 0 Conventional Airconditioning Rack Liquid Cooling (CoolTherm) Ó by

TCO Study: Profitability Calculation Observation Period 15 Years, Service Life of Racks 6 / 12 / 15 Years 500'000 Savings: 110.000 /a 450'000 Costs [ /a] 400'000 Savings: 130.000 /a Savings: 140.000 /a 350'000 300'000 250'000 200'000 150'000 100'000 50'000 0 Option 1 Option 2 / 6 years Capital-related payments Requirement-related payments Electricity costs Option 2 / 12 years Option 2 / 15 years Operation-related payments Maintenance, inspection and operation Requirement-related payments Waste heat recovery potential Ó by

Conclusions Ó by

Knurr High Density Cooling Solutions that Work! We offer scalable solutions from 4kw to 25 kw. CPU Liquid Cooling > 100W/CPU Combined Rack + CPU Liquid Cooling Rack Liquid Cooling Forced Air Free Air 1 3 5 8 10 15 20 25 30... kw / Rack CoolTherm CoolBoost Miracel Ó by

Conclusions Limits of air cooling reached at w 3-4 kw / rack (full density deployment) Liquid cooling overcomes the «heat barrier» and allows high density applications. Technology and products are already available: Complete data center solutions for rack and CPU cooling Liquid cooling provides considerable reduction of - Floor space - Energy consumption - TCO proves that the products work. Knurr has more installations than any body in the world that are Reliable and proven to work.! Ó by

Thank You Ó by

Knurr High Density Cooling Solutions that Work! CPU Liquid Cooling > 100W/CPU Combined Rack + CPU Liquid Cooling Forced Air Thank You! Rack Liquid Cooling Free Air 1 3 5 8 10 15 20 25 30... kw / Rack CoolTherm Miracel CoolBoost Ó by