FACTORY AUTOMATION QUICK START GUIDE IC-KP-*

Similar documents
QUICK START GUIDE IC-KP2-*

FACTORY AUTOMATION MANUAL CBX500 HOST INTERFACE MODULES

QUICK START GUIDE 2-D Laser Scanner

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

FACTORY AUTOMATION. QUICK START GUIDE VBP-HH1-V3.0-V1 AS-Interface Handheld

FACTORY AUTOMATION MANUAL WCS-MBG110 WCS MODBUS RTU INTERFACE MODULE

FACTORY AUTOMATION. MANUAL OHV-F230-B17 PROFINET Gateway for OHV Handheld

FACTORY AUTOMATION MANUAL PMI360D-F130-IE8-V15 INDUCTIVE POSITIONING SYSTEM

FACTORY AUTOMATION MANUAL ODZ-MAH-B15-M3

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

MANUAL Conversion instruction EDM series to VDM100 series

FACTORY AUTOMATION. QUICK START GUIDE IUH-F190-V1-* Read / Write Head for IDENTControl

MANUAL PCV Parameterization Tool

FACTORY AUTOMATION MANUAL MAH* FIRMWARE UPGRADE INSTRUCTIONS

FACTORY AUTOMATION MANUAL CBX800

QUICK START GUIDE ODT-MAC40*-*-RD

FACTORY AUTOMATION. QUICK START GUIDE OHV200-F22*-B15 Handheld reader

FACTORY AUTOMATION MANUAL PMI360DV-F130-IU2E2- V15

QUICK START GUIDE ODT-HH-MAH300 Handheld

MANUAL Encoders with J1939 Interface

FACTORY AUTOMATION MANUAL IC-KP-B6-V15B IC-KP-B6-2V15B IC-KP-B6-SUBD

FACTORY AUTOMATION MANUAL VISION CONFIGURATOR

FACTORY AUTOMATION INSTRUCTION MANUAL INDUCTIVE POSITIONING SYSTEM -F90

FACTORY AUTOMATION. MANUAL VBA-4E3A-G20- ZEL/M1L-P2 AS-Interface Motor Control Module

MANUAL PHA...-F200-B6-V15B

FACTORY AUTOMATION. MANUAL IQT1-*-R4-V1 RFID R/W systems, MHz

FACTORY AUTOMATION. CONFIGURATION INSTRUCTIONS WCS3B-LS*** with RS485 interface

MANUAL Surge Protectors

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

FACTORY AUTOMATION MANUAL LS670-DA

FACTORY AUTOMATION INSTRUCTION MANUAL. AS-Interface Safety at Work VAA-2E-G4-SN. Version 1.2

FACTORY AUTOMATION TAMING THE POWER F99 SERIES INCLINATION AND ACCELERATION SENSORS

MANUAL IPT*-FP with U-P*-RX

FACTORY AUTOMATION. MANUAL R CANopen Protocol

VersaMax IP Input Module

FACTORY AUTOMATION. Manual Speed Monitor KFU8-DW-1.D

FACTORY AUTOMATION. Manual IVI-KHD2-4HD1. Control Unit

MANUAL Optical data coupler LS600-DA-IBS

FACTORY AUTOMATION MANUAL VBP-HH1-V3.0-V1

FACTORY AUTOMATION. Manual IVI-KHD2-4HD3. Control Unit with 8 Inputs/Outputs

MANUAL LML-P, LML-S, LML-Ex

FACTORY AUTOMATION MANUAL IQT-F116-R4-V1 IQT-F116-R4M-V1

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

FACTORY AUTOMATION. MANUAL PXV...-F200-B17-V1D Data Matrix Positioning System

Control Interfaces IDENTControl Control Interfaces IDENTControl Compact Read/Write Heads , 926, 927

MANUAL RFID Supervisor

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

FACTORY AUTOMATION MANUAL DK12-11-IO PRINT MARK CONTRAST SENSOR WITH IO-LINK INTERFACE

MANUAL HART Multiplexer System

FACTORY AUTOMATION MANUAL IC-KP-B6-SUBD. IDENTControl interface with PROFIBUS DP interface

PROCESS AUTOMATION. Manual KF!!-UFT-(EX)2.D ROTATION DIRECTION INDICATOR AND CONSTANT SPEED MONITOR

MANUAL Installation and Configuration

Table of Contents. AS-i Modbus Plus-Gateway Table of Contents. 1 Declaration of Conformity The Used Symbols...6

BNI PBS Z001. IP67 module, Profibus IO-Link Master Short Guide

FACTORY AUTOMATION. MANUAL Absolute Rotary Encoders Integration into PROFINET

VersaMax IP I/O Module

Addendum for 125B Bushealth Measurements

User Manual HMI Linkbox HL01 DP/MPI

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Quick start guide

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

Dimensions. Electrical connection. Technical data. General specifications Operating frequency. Functional safety related parameters MTTF d

FACTORY AUTOMATION. MANUAL Absolute Rotary Encoder with PROFIBUS Interface

6Inclination and Acceleration Sensors

PROCESS AUTOMATION MANUAL. Temperature Trip Amplifier. KFD2-GU-(Ex)1 ISO9001

PROCESS AUTOMATION. QUICK START GUIDE FieldConnex Diagnostic Manager

Hardware Manual RM CANview

FACTORY AUTOMATION. PROGRAMMING SOFTWARE VisoSetup

FACTORY AUTOMATION. Manual Absolute Rotary Encoder for DeviceNet

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

BNI PNT Z015. IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide

MANUAL MODULAR SEGMENT PROTECTOR

Digital Proportional Power Plug

Fieldbus Gateway Type ME43

ABSOLUTE ROTARY ENCODER ETHERNET/IP

Dimensions. Electrical connection. Technical data. General specifications Operating frequency. Indicators/operating means. Electrical specifications

FACTORY AUTOMATION. MANUAL Absolute Rotary Encoders With EtherCAT Interface

Manual Fiber Optic Interfaces

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6

FACTORY AUTOMATION SAFETY LIGHT CURTAINS SLCS AND SLCT SERIES

FACTORY AUTOMATION. M18 Threaded light beam switches

Operating instructions Memory plug E /02 11/2011

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BKS. Contents Connectors and accessories. Micropulse Transducers

FACTORY AUTOMATION MANUAL ODT-MAC40*-*-RD

Dimensions. Electrical connection. Technical data. General specifications Operating frequency. Functional safety related parameters MTTF d

BCC Part Number Matrix Breakdown Balluff cables, cordsets & connectors for industial automation equipment

IMAGE-BASED CODE READERS

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 Short Guide

Inclination sensors 1-dimensional, measuring range

Bus Interface Connector System Versions for Bitbus, CAN -Bus, Interbus -S (field bus) and Profibus

AMG 11. Features. Optional. Additional incremental output (TTL / HTL) AMG 11. Technical data - mechanical design. Technical data - electrical ratings

The sensor fulfills the specifications of the EMC requirements, if the instructions in the manual are followed.

BNI EIP Z016. IP67 Modules, 8 Outputs BNI EIP Z016 BNI EIP Z016 IP67 Modules, 16 Outputs User s Guide

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

ERbic. Bus Interface Connector System Catalog E /06 Edition 4

PROCESS AUTOMATION MANUAL. Universal Temperature Converter KCD2-UT2-(Ex)1 ISO9001

Quick Connectors for PROFIBUS SUBCON-PLUS-PROFIB/...

Transcription:

FACTORY AUTOMATION QUICK START GUIDE IC-KP-* IDENTControl units

With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.v.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship"

Contents Introduction... 4. Purpose of this quick start guide...4. Product documentation on the internet...4 Product Description... 5. Product family...5. Connection accessories...5.. Connection cable for R/W heads and trigger sensors...5.. Cable connectors for the power supply...6.. Network cable to the Ethernet interface...7..4 Connection cable to the PROFIBUS DP interface...8..5 Connection cable to the serial interface...9 Installation... 0. Contact protection...0. Interface connections...0.. Serial interfaces...0.. Ethernet connection guide..... INTERBUS connection guide.....4 PROFIBUS connection guide...4..5 DeviceNet connection guide...6..6 Command Interface connection guide...7. Power supply...8.4 Read/Write Head and Trigger Sensors...9.5 Cable length between control interface and R/W heads...9.6 Ground connection...9 4 Commissioning... 0 4. Connection...0 4. Setting the IP address...0 5 Technical Specifications... 5. Dimensions...

Introduction Introduction. Purpose of this quick start guide This quick start guide contains basic instructions for operating the device. However, the manual takes priority over the quick start guide.. Product documentation on the internet You can view all the relevant documentation and additional information on your product at http://www.pepperl-fuchs.com. Simply enter the product name or model number in the Product/Key word search box and click Search. Select your product from the list of search results. Click on the information you require in the product information list, e.g., Technical documents. A list of all available documents is displayed. 4

Product Description Product Description. Product family The brand name IDENTControl represents a complete identification system. The system consists of an IDENTControl control interface with bus interface, inductive read/write heads (5 khz and.56 MHz), read/write heads with electromagnetic coupling (UHF with 868 MHz) and the associated read only and read/write tags in a number of different designs. IDENTControl is open and can be connected to other identification systems.. Connection accessories.. Connection cable for R/W heads and trigger sensors Compatible connection cables with shielding are available for connecting the R/W heads and trigger sensors. Figure. Accessories Description m long (straight female, angled male) V-G-M-PUR-ABG-V-W 5 m long (straight female, angled male) V-G-5M-PUR-ABG-V-W 0 m long (straight female, angled male) V-G-0M-PUR-ABG-V-W 0 m long (straight female, angled male) V-G-0M-PUR-ABG-V-W Field attachable female connector, straight, shielded Field attachable male connector, straight, shielded Field attachable female connector, angled, shielded Field attachable male connector, angled, shielded Dummy plug Mx V-G-ABG-PG9 VS-G-ABG-PG9 V-W-ABG-PG9 VS-W-ABG-PG9 VAZ-V-B 5

Product Description.. Cable connectors for the power supply Compatible M sockets with an open cable end for connecting the IDENTControl to a power supply are available in different lengths. Figure. Accessories Length m (straight socket) Length 5 m (straight socket) Length 0 m (straight socket) Designation V-G-M-PUR V-G-5M-PUR V-G-0M-PUR The IDENTControl IC-KP-B7-AIDA is connected to the power supply via a connector that complies with the AIDA directive. Figure. Accessories Field attachable connector for power supply MSTB connecting cable to M connector MSTB connecting cable to open cable end Designation ICZ-AIDA-MSTB ICZ-AIDA-MSTB-0.M-PUR-V-G ICZ-AIDA-MSTB-5M-PUR 6

Product Description.. Network cable to the Ethernet interface The IDENTControl IC-KP-B-V45 is connected to the network via an RJ45 socket. An RJ45 connector seal compatible with the Ethernet network cable is available for mobile applications in accordance with IP67. Figure.4 Accessories IP67 network connector seal Network cable RJ45, category 5, up to 00 MHz, 0 m Designation ICZ-V45 V45-G-0M-V45-G..4 Network Cable to the Ethernet Interface The IDENTControl IC-KP-B7-AIDA is connected to the network via a connector that complies with the AIDA directive. Figure.5 Accessories Field attachable connector for RJ45 RJ-45 connecting cable, D-coded to M Stopping plugs Designation ICZ-AIDA-V45 ICZ-AIDA-V45-0,M-PUR-VD-G ICZ-AIDA-B Connector Assignment Signal Marking on connector TD+ TD- RD+ RD- Yellow Orange White Blue 7

Product Description..5 Connection cable to the PROFIBUS DP interface The IDENT Control has a B-encoded M connector and is connected to the network using a suitable cable. Figure.6 Accessories Terminator T distributor Y connection cable Connection cable with terminator Connection cable m Cable socket, screw terminal type Cable plug, screw terminal type Description ICZ-TR-V5B ICZ-T-V5B ICZ-T-0.M-PUR ABG-V5B-G ICZ-T/TR-0.M-PUR ABG-V5B-G V5B-G-M-PUR ABG-V5B-G V5B-G V5SB-G. Connection cables are available in the following lengths: m, m, 5 m, 7 m, m, 5 m. Note! The T-distributor is designed for general applications in the PROFIBUS network only and is not compatible with the IDENT Control. The Y connection cable must always be used with the IDENT Control. 8

Product Description..6 Connection cable to the serial interface The IDENT Control IC-KP-R-V has an M connector and is connected to the host using a suitable cable. Figure.7 Accessories M cable connector, shielded, field-attachable Adapter cable, M to Sub-D (for connection to a PC using a null modem cable) Null modem cable Sub-D Designation VS-G-ABG-PG9 VS-G-0.5M-PUR-ABG-SUBD IVZ-K-R 9

Installation Installation. Contact protection Our housings are manufactured using components made partly or completely from metal to improve noise immunity. Read head IDENTControl Compact Danger! Electric shock The metallic housing components are connected to ground to protect against dangerous voltages that may occur in the event of a fault in the SELV power supply!. Interface connections.. Serial interfaces Connect the RS interface with the M socket. You must place the cable shield on the thread in the connector plug. 4 5 Pin assignment of the M socket for RS NC RxD GND 4 TxD 5 NC 0

Installation.. Ethernet connection guide IC-KP-B-V45: Network connection The network is connected via an RJ45 connector. The following illustration shows the pin assignment: 4 5 6 7 8 TD+ TD- RD+ 4 Not used 5 Not used 6 RD- 7 Not used 8 Not used Caution! The RJ-45 network socket is connected galvanically to the grounded housing. The Ethernet/IP specification does NOT require the use of Ethernet cables with a shield connected to the RJ-45 plug at both ends. However, we recommend using cables with a continuous shield only, in order to avoid EMC issues. Transfer rates, line lengths and line types The device can be operated in 0 Base-T or 00 Base-TX networks. The maximum total line length is 00 m in both cases and only shielded network cables from category 5 or above can be used. Compatible connecting cablessee chapter...

Installation IC-KP-B7-AIDA: Network connection Connect the network to the IDENTControl using a connector that conforms with AIDA. Two sockets with the following pin assignment are located on the housing: TD+ TD- RD+ Not used Not used RD- Not used Not used Caution! The network socket is connected galvanically to the grounded housing. The Ethernet/IP specification does NOT require the use of Ethernet cables with a shield connected to the RJ-45 plug at both ends. However, we recommend using cables with a continuous shield only, in order to avoid EMC issues. Note! Protection degree IP67 If you use only one of the two network connections, you must close the unused network port with the blind plug ICZ-AIDA-B to achieve the protection degree IP67. The blind plug ICZ-AIDA-B is available as an accessory. See chapter..4. Transfer rates, line lengths and line types The device can be operated in 0 Base-T or 00 Base-TX networks. The maximum total line length is 00 m in both cases and only shielded network cables from category 5 or above can be used. Refer to the relevant chapter for information on compatible connecting cables.

Installation.. INTERBUS connection guide IC-KP-B5-V: Round connector: Connector - incoming interface 8 7 6 5 9 4 DO /DO DI 4 /DI 5 GND 6 NC 7 NC 8 NC 9 NC Round connector: Socket - outgoing interface 8 9 7 6 4 5 DO /DO DI 4 /DI 5 GND 6 NC 7 NC 8 NC 9 /RBST

Installation..4 PROFIBUS connection guide IC-KP-B6-V5B: The data lines RxD/TxD-P and RxD/TxD-N are also referred to as A and B lines. There are no PROFIBUS specifications that indicate which color wire on the data cable should be attached to which terminal. The wire color must be unified within the entire plant. If you use a transfer cable with red and green wires, we recommend the following assignment: RxD/TxD-N (A line): RxD/TxD-P (B line): green red The PROFIBUS-DP is connected via a B-encoded M socket and a B-encoded M connector. The last node on the bus must be terminated using terminator ICZ-TR-V5B on the outgoing socket. The shield is connected to the IDENTControl via the knurled nut on the connector. 5 5 4 4 Pin Connector assignment Socket assignment NC VP RxD/TxD-N RxD/TxD-N NC DGND 4 RxD/TxD-P RxD/TxD-P 5 NC NC IC-KP-B6-SUBD: The data lines RxD/TxD-P and RxD/TxD-N are also referred to as A and B lines. There are no PROFIBUS specifications that indicate which color wire on the data cable should be attached to which terminal. The wire color must be unified within the entire plant. If you use a transfer cable with red and green wires, we recommend the following assignment: RxD/TxD-N (A line): RxD/TxD-P (B line): green red The PROFIBUS DP is connected via a 9-pin Sub-D socket. The cable shield must be placed on the thread in the flange of the connecting plug. 4

Installation 5 4 9 8 7 6,, 4, 7, 9 NC RxD/TxD-P 5 DGND 6 VP 8 RxD/TxD-N IC-KP-B6-V5B: The data lines RxD/TxD-P and RxD/TxD-N are also referred to as A and B lines. There are no PROFIBUS specifications that indicate which color wire on the data cable should be attached to which terminal. The wire color must be unified within the entire plant. If you use a transfer cable with red and green wires, we recommend the following assignment: RxD/TxD-N (A line): RxD/TxD-P (B line): green red The PROFIBUS DP is connected via a B-encoded M socket. This socket is connected to the Y line ICZ-T-0.M-PUR ABG-V5B-G so that it can be connected to the bus. Other Y lines can also be connected. Several IDENTControls can be connected directly to the PROFIBUS via several Y lines. The last node on the bus must be connected to the cable from the previous model with a ICZ-T/TR-0.M-PUR cable with integrated terminator. The shield is connected to the IDENTControl via the knurled nut on the connector. 5 4 VP RxD/TxD-N DGND 4 RxD/TxD-P 5 NC 5

Installation..5 DeviceNet connection guide IC-KP-B7-V95: Network connection The network connection is established using a DeviceNet MiniStyle connector. The pin assignment is taken from the drawing below. 4 5 Ground / uncoated V+ / RD V- / BK 4 CAN_H / WH 5 CAN_L / BU Connecting cable The device must always be connected using the "Thick" and "Thin" extension cables described in the DeviceNet specification. Refer to the "Thick cable profile" and "Thin cable profile" sections in the DeviceNet specification for more detailed information. Transfer rates and cable lengths Baud rate Max. length of the transfer cable 5 kbits/s 500 m 50 kbits/s 50 m 500 kbits/s 00 m 6

Installation..6 Command Interface connection guide IC-KP-R-V: The IDENTControl is fitted with serial interface RS. Select the transfer rate (baud rate) using the software or the display. The following transfer rates are available: 00, 400, 4800, 9600, 900, 8400 bits/s The status is preset at 9600 Mbit/s on delivery. The device operates with the following parameters (permanent): 8 data bits start bit stop bit No parity Connect the RS interface via a 4-pin M socket. You must place the cable shield on the thread in the connector plug. 4 Pin assignment of the M socket for RS NC RxD GND 4 TxD RxD TxD RxD TxD 4 GND GND Transfer rates, line lengths and line types The maximum length of the cable between the control unit and the higher level computer depends on the transfer rate and the noise level. We recommend the following guide value: Standard RS Host-PC Max cable length 5 m IC-KP-R-V 7

Installation. Power supply Connect the power supply via an M connector with integrated voltage and reverse polarity protection indicator (green: correct polarity, red: reverse polarity). A plug with the following pin assignment is located on the housing: 4 + 4 V NC GND 4 NC Power supply AIDA Connect the power supply for the IDENTControl using a connector that conforms with AIDA. A plug with the following pin assignment is located on the housing: 45 + 4 V GND n.c. 4 n.c. 5 n.c. Compatible connecting cable see chapter... 8

Installation.4 Read/Write Head and Trigger Sensors A maximum of 4 read/write heads can be connected to the IDENTControl. Instead of the read/write heads, a maximum of trigger sensors can be connected to sockets and 4. A trigger sensor can be assigned to only one read/write head. The trigger sensors must be PNP. Connect the read/write heads and trigger sensors to the sockets on the top of the enclosure using M connectors. socket at housing read/write head trigger sensor trigger switch 5 4 4 5 + A - B + signal - For details of compatible read/write heads and of compatible connecting cables, see chapter....5 Cable length between control interface and R/W heads The maximum cable length between the control interface and a connected R/W head is 000 meters. If you wish to attain the maximum possible cable length, select a suitably large cable cross-section. See chapter...6 Ground connection The ground connection of the IDENTControl is located at the lower right of the connector array. The ground conductor is screwed to the housing with a crimp connector. In order to guarantee safe grounding, the serrated washer must be mounted between the crimp connector and the housing. 4 Housing Serrated lock washer Crimp connector 4 Lock screw A cross-section of at least 4 mm is recommended for the ground conductor lead. 9

Commissioning 4 Commissioning 4. Connection This section contains information on how to commission the IDENTControl. The example commissioning procedure described relates to the IDENTControl with Ethernet interface. Caution! Uncontrolled triggered processes Before commissioning the device, make sure that all processes are running smoothly; otherwise damage may occur in the plant. Warning! Incorrect electrical connection Damage to the device or plant caused by incorrect electrical connection. Check all connections in the plant before commissioning the device. After the supply voltage is connected, the green LED in the voltage connector and the PWR State LED (after a few seconds) on the display panel must light up. If the LED in the connector lights up red, the polarity of the power supply is reversed. 4. Setting the IP address The IP address of the IDENTControl is preset to 69.54.0.. The way in which the IP address is modified depends on if you are using a DHCP server. If you are not using a DHCP server, the IP address is manually assigned: You preset the IP address using the display and the buttons. If you are using a DHCP server (or operating via a PROFINET), the server assigns the IP address to the IDENTControl. Note! We recommend using a fixed preset IP address in order to avoid system malfunctions. 0

Technical Specifications 5 Technical Specifications 5. Dimensions 48 6 66 67 49 07 Ground Connector array 7.5 4 4 6.5 0

FACTORY AUTOMATION SENSING YOUR NEEDS Worldwide Headquarters Pepperl+Fuchs GmbH 6807 Mannheim Germany Tel. +49 6 776-0 E-mail: info@de.pepperl-fuchs.com USA Headquarters Pepperl+Fuchs Inc. Twinsburg, Ohio 44087 USA Tel. + 0 45555 E-mail: sales@us.pepperl-fuchs.com Asia Pacific Headquarters Pepperl+Fuchs Pte Ltd. Company Registration No. 99000E Singapore 994 Tel. +65 6779909 E-mail: sales@sg.pepperl-fuchs.com www.pepperl-fuchs.com Subject to modifications Copyright PEPPERL+FUCHS Printed in Germany 549 TDOCT999C_ENG 0/0