The Power Generation Display Unit is available in two sizes as described in the following table:

Similar documents
IS-DM220/IR/HB IS-DM220

SNA KIT Assembly Guide

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03

Digital I/O Module. Impro (DIO) Digital I/O Module INSTALLATION MANUAL

7" Touch Screen Display

Three Phase Residential Solution for Australia, System Design and Installation Guidelines

Insert the male, 90 angled, 2x10 connectors into the corresponding 2x10 sockets and put them in place, flat under the PCB. Solder.

Elecraft W1 SWR/Wattmeter Enclosure by W8FGU

Topic: TB No.: Date: Aug/2017. Model UC4, UC10 & UC45 twin pump variants Regulated 24V Pump Power supply upgrade OVERVIEW

The Shop Interface Unit allows MxPro 4 control panels to send and receive alarm signals from other equipment.

FITTING INSTRUCTIONS

USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions

Guide for installers. METTLER TOLEDO MultiRange Explosion-protected weighing system with the ID7sx weighing terminal

Installing a Power over Ethernet injector

USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version

The Exp-007 unit connects directly to Remote Status Indicator units to provide 2 programmable 1-Amp rated, volt free, clean contact outputs.

Adapter Kit - QSI Electronics to TM Meter Installation Instructions

LaserLyte-Flex Red & Green Alignment System

Advanced Visual Solutions Ltd

DMD Extender. Application Note 1 Sega Large Screen LCD Replacement. V0.1 October 2013 Copyright 2013 Dr Pinball

E2460GS Oscilloscope Upgrade Kit

User Guide Attracta Magnetic Lighting

IECEx Certificate of Conformity Annexe

AI-102. IR Illuminator. Installation Guide. Rev IP Surveillance

Seeburg JCU-DEC Kit Convert Your Seeburg DEC Wallbox Into a Jukebox

Installing a LIF port into the IC-703 transceiver

StationPro II Network Manual rev. 06/27/2010

Replacement Keyswitch Assembly

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide

Installation Guide for Mazak Mazatrol M - Plus, M-2, M32, T-Plus, T2

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Bullet Camera Installation in an Outdoor Enclosure

Quicksilver 606 TR-606 CPU Upgrade

Adapter Kit - Remote QSI Electronics Installation Instructions

REMOTE HEAD ADAPTER INSTALLATION GUIDE

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

Vintage Korg CX-3 Board Repair Service Kit

PADPULS2 M-BUS Pulse Input Modules

Metham Aviation Design Limited Station Approach, Four Marks, Alton. Hants. GU34 5HN Tel +44 (0) Fax +44 (0)

Adapter Kit - QSI Electronics to G2 Meter Installation Instructions

Calder Centaur Workshop Manual

Note: These installation instructions are only for the 4430/4440 Sprayer. For other SPX models please refer to P/N , &

FDS-B737NG-ELEC-CAB-SYS Installation Instructions

MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLUH HV 4/12) blunt cut at BTS side

VCM Systems Vehicle Control Module Systems

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

FC-25/50DA Main Circuit Board Replacement Product Installation Document

JUN 2016 Rev B

Dissecting a keyboard

INSTRUCTIONS FOR THE INSTALLATION OF THE INFINITY "L" DISPLAY HOOD (INTO PREVIOUSLY INSTALLED INFINITY "L" SYSTEMS)

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

EQ573 Assembly guide. EQ573 Assembly guide Main board 1. Diodes. 2. Resistors (1) 3. Test pins. 4. Ceramic capacitors.

Landmark Upgrade Kit Installation Instructions

INSTALLATION INSTRUCTIONS

Densitron Ferrograph. Build Instructions. Rhapsody Unit

Instructions to Install Retrofit Kit RVMC 4/5000 Machine (MDB Only)

WBS HARDWIRED SERIES 4-60KVA MAINTENANCE BYPASS SWITCH

Installation Notes TII Model 341 Protector

12-Bit 0-5 Volt Input Adapter (Part # S-VIA-CM14)

SNOWBOARD RACK KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 25

Installing Keypad and Backplate

Microscope with original illuminator. Microscope with Nanodyne replacement illuminator.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

EMC 10/4 "CE" Mechanical Upgrade Procedure

WARNING. General Information

TCNM-ACBB1 Installation Manual

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

SITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions

An ISO 9001 Company. BOP 1KW-MG FIRMWARE RETROFIT KIT

Hardware Installation. In this chapter... Custom Labels EMI Noise Filter Installation Mounting DIN Clip Mounting Connections and Wiring

EMC 10T "CE" Mechanical Upgrade Procedure

Internal Printer. Features.

BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual

PLC Racks IC697CHS782/783

INSTALLATION PROCEDURE FOR THE INNOVEC IPT POWERED PRINTING TOTALISOR

Installation Instructions

13 MMC for PC Option Modules

into the EMU E4 Classic and E4 Platinum Samplers

Encore XT Manual Gun Upgrade Kit

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

User English Manual for Sputnik Stereo Camera

Assembly and Setup Manual

Pandora Assembly Instructions With Diamond Systems PC/104 CPUs (Athena, Elektra and Prometheus) November, 2006

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Mounting on the Ceiling Using Flush Mount (Face Down)

ELECTRO-MECH SCOREBOARD CO.

Voice Evacuation Control Panel Main Circuit Board Replacement Product Installation Document

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

UF-3701 Power Board Construction Guide

QRPometer Assembly Manual Copyright 2012 David Cripe NM0S The 4 State QRP Group. Introduction

Instruction Manual. ICENI/TB-02 Terminal Block Module (Type 2) Pub_ Issue 1

TopConsole system TP. Combination options 1-part 2-part 3-part. System accessories Page 537 Monitors, keyboards From page 796 Climate control Page 389

NewScope-7B Operating Manual

Strobe Light. Student Lab Guide. Engineering Teaching Laboratory. Lab Partner(s) Page 1 of 10

FLEXBOX. Installation Guide

INSTALLATION INSTRUCTIONS

ENTRACOMP 26SA With Remote Open Input. User/Installation Manual

USER MANUAL. RC-43T Remote Controller MODEL: P/N: Rev 3

Transcription:

Micha www.micha.co.uk Power Generation Display Unit 801309 1. Introduction The Power Generation Display Unit is designed to display the power generated by any Power Generation system but is usually used on a renewable energy generation site, e.g. Photovoltaic (PV) or Wind. For a PV system, PV panels would typically be installed on a building and provide power directly to the mains grid via inverters. Energy meters provide pulses to the Power Generation Display Unit to enable the energy generated to be counted and displayed. The Power Generation Display Unit is available in two sizes as described in the following table: Micha Part Number Description Graphic Size 101 820 Power Generation Display Unit 420mm wide x 300mm high (A3 Graphic Size) 101 640 Power Generation Display Unit 600mm wide x 500mm high MF/11 th April 2013/Issue 8 Page 1 of 12 The Micha Design Company Ltd

INPUT 4 INPUT 3 INPUT 2 3 TB5 D1 D2 D3 D4 TR1 TR2 TR3 TR4 SW1 SW2 SW3 IC5 SW4 TB6 C2 TP1 IC3 IC4 IC6 TP2 TP7 LED5 R10 TP4 LED2 RN4 TP5 LED3 TP6 LED4 PSU1 C3 C14 IC9 C13 C11 IC7 C12 IC8 PROGRAM PORT J4 C7 C9 C10 R8 XTAL1 IC2 SW8 RN1 RN3 C6 RN2 SW7 SW10 R2 R4 C8 R6 R1 C4 R3 R5 1 CONTRAST SW9 RED VE WHT -VE J1 Micha Design Power Generation Display Unit 801309-8.doc 2. General Arrangement The unit comprises a back-box which houses the Power Supply PCB, Control PCB and Display PCB Assemblies. The back-box is covered with two sheets of clear acrylic (420 x 300mm or 600 x 500mm) which are designed to trap a fixed graphic of the end users choice. The backlit graphics display is visible through an aperture in the graphic. The sheets of acrylic are held together by the surrounding bezel and M8 fixings. 605mm 4 x M8 DOME NUTS REAR PERSPEX - WITH CUT-OUT FOR GRAPHICS DISPLAY 8 x M16 BLANKING PLUGS FRONT PERSPEX - NO CUT-OUT 4 x BACK BOX FIXINGS EARTH STUD SUPPLY PCB GENERATION DISPLAY UNIT PCB ASSEMBLY MDC 401 221 EARTH NEUTRAL LIVE F1 BEZEL SP NO COM SP NO COM SP NO COM SP NO COM INPUT 1 1 2 1 2 3 1 2 3 1 2 3 R11 R12 R15 R18 R19 R16 R20 R21 R23 R25 R26 R22 SW6 SET R13 R14 RUN PN: 401195 ISSUE GENERATION CONTROL PCB ASSEMBLY ORIGIN: U.K.Micha COUNTRY OF R27 R24 R17 J3 MENU DOWN UP LIGHT BACK J2 VR1 SELECT GRAPHICS DISPLAY PCB 505mm BACK BOX CONTROL PCB 4 HOLES FOR POSSIBLE CABLE ENTRY 8 x REAR ACRYLIC FIXINGS EXTERNAL SET-UP CONTROL UNIT CONNECTOR 2.1. NOTE: Display When fully assembled, the Display sits slightly proud of the metal back-box. For this reason the unit is supplied in parts which are typically assembled at installation time. The Display should not be fitted to the four nylon pillars provided until the back-box has been fitted to the supporting wall see section 3.4 MF/11 th April 2013/Issue 8 Page 2 of 12 The Micha Design Company Ltd

3. Installation 3.1. Disassembly Carefully remove the four M8 fixings in the four corners of the bezel and remove the bezel.. If this is an existing installation, remove the tape which is applied to the edge of the two sheets of acrylic (this should be done carefully to avoid dropping the front sheet of acrylic). Remove the front sheet of acrylic and any graphic that is installed. Remove the eight M4 countersunk screws that hold the rear sheet of acrylic to the back box. 3.2. Installation of Back Box Using the back box as a template, mark the position of the four mounting holes onto the desired location. Drill and fit rawl plugs or other suitable fixings to hold the back box to the wall. Fix the back box to the wall. The unit requires mains power and the signal for the energy meter. These cables may be brought into the enclosure using the large holes on the back wall of the enclosure, or through any of the eight cable gland holes provided (remove the blanking plug and fit M16 glands as required). Connect the mains to the Power Supply PCB Assembly using the cable clamp arrangement provided and ensuring the connections are tight. Note: with Version 1 PSU, the Earth cable should be connected to the pcb terminal, on Version 2 PSU, the Earth cable should be connected directly to the earth stud on the back-box. Connect the Volt-Free Pulse Output from up to four Energy Meters to the inputs marked Input 1-4 on the Control PCB Assembly. See diagram below and Section 3.4. UP TO 4 METERS MAY BE CONNECTED SUPPLY PCB GENERATION DISPLAY UNIT PCB ASSEMBLY MDC 401 221 R1 EARTH PSU Ver.2 PSU Ver.1 METER 4 METER 3 METER 2 METER 1 MAINS CABLE NEUTRAL LIVE F1 PSU1 VOLT-FREE PULSE OUTPUT VOLT-FREE PULSE OUTPUT VOLT-FREE PULSE OUTPUT Control PCB Assembly See Section 3.4 VOLT-FREE PULSE OUTPUT 3.3. Energy Meter Pulse Output The Unit is capable of sensing pulses that have an on and off time of at least 100ms. See diagram below. METER VOLT-FREE PULSE OUTPUT ON OFF 100mS MIN 100mS MIN MF/11 th April 2013/Issue 8 Page 3 of 12 The Micha Design Company Ltd

3.4. Control Printed Circuit Board (PCB) Control PCB Issue 4: Connect any of the following Energy Meter Output Connections to any Control PCB Input 1, 2, 3 or 4: (Energy Meters manufacturers mark the SO Pulse output in different ways) METER OUTPUT Connect to Terminal 2 (NO) Connect to Terminal 3 (COM) METER OUTPUT Connect to Terminal 2 (NO) Connect to Terminal 3 (COM) METER OUTPUT Connect to Terminal 2 (NO) Connect to Terminal 3 (COM) SWITCHED POSITIVE OUTPUT 5-12V Connect to Terminal 1 (SP) Connect to Terminal 3 (COM) Control PCB Issue 4 Layout: Up to 4 inputs can be connected MF/11 th April 2013/Issue 8 Page 4 of 12 The Micha Design Company Ltd

3.5. Display Installation After the back-box has been securely fitted to the supporting wall, unpack and carefully fit the Display to the four nylon pillars using a pozi-screw and nylon washer (provided) on each corner of the Display (do not overtighten). Plug the ribbon cable into the corresponding connector (J2) on the Control PCB and plug the back-light connector into its corresponding connector (J1). Remove the protective plastic covering the Display at this point (3 or 4 strips of plastic). 3.6. Set up At this point, apply mains power to the unit. Set the Set/Run switch on the Control PCB Assembly to SET. Use the Menu switch to advance through the following parameters in sequence (see photo below): When a parameter is flashing, use the Up and Down switches to adjust. When the unit is set to RUN, all parameters will be stored in non-volatile memory. See section 3.8 regarding the External Set-up Control Unit. 3.6.1. Set Pulse Value The Energy Meters produce pulses which represent Watt-hours (Wh) being generated. The unit needs to be programmed to set the Pulse Value in Wh. Also, if a number of identical systems are in place but only one of the systems has energy meters fitted, then the Pulse Value can be multiplied by 1 to 40 to enable the display to show the energy for the entire arrangement. First set the number of systems (1 to 40) using the Up and Down switches. Press Menu. Now set the Pulse Value (1Wh, 10Wh, 100Wh, 1kWh, 10kWh per pulse). Press Menu. MF/11 th April 2013/Issue 8 Page 5 of 12 The Micha Design Company Ltd

3.6.2. Set Instant Power Time The instantaneous power being generated is calculated by counting the number of pulses received over a period of time. This parameter should be set for a time that allows a number of pulses to be received (which depends on the size of the system and the pulses sent out by the energy meter). The Instant Power Time interval can be set to 1, 2, 3, 5, 10, 12, 15, 20, 30 and 60 minutes. The instantaneous power generated will appear on the display after the time selected and then remain unchanged until the next update. 3.6.3. Set Total Energy If a display unit is being installed after the system is up and running or as a replacement, it may be desired to enter the energy in Watt-hours (Wh) that has already been generated. The installer may set the Total Energy as any 10-digit number representing Total Energy in Wh. How to set Total Energy: When any digit of this parameter is flashing, use the Up and Down switches to change the digit. Use the Menu switch to advance through all the digits. (The example below shows how to set 1234kWh) Important: Press the SELECT switch to update the Set Total Energy figure. 3.6.4. Testing the unit Each of the Pulse Inputs has a test switch associated with the input terminal connector. By pressing the test switches the installer may simulate pulses being received and see the results on the display. 3.7. Installation of Acrylic Sheets Using the eight M4 countersunk screws, fix the rear sheet of acrylic to the back box. Place the graphic and the front sheet of acrylic onto the rear sheet of acrylic and temporarily fix them together using the top two M8 fixings. Apply clear self-adhesive tape all the way round the edges of the two acrylic sheets to seal the two together. This is important as it can prevent small insects or moisture getting between the two sheets and affecting the appearance of the graphic and display. Using the four M8 fixings, fix the bezel in place (note that the front sheet will only be held in place by the adhesive tape if the top two fixings are removed and the sheet is not supported). The four M8 fixings should be inserted from the rear and the dome top nut used to secure the front. MF/11 th April 2013/Issue 8 Page 6 of 12 The Micha Design Company Ltd

3.8. External Set-up Control Unit Units produced after June 2010 have the facility to connect an External Set-up Control Unit via a 9-way D-type connector on the bottom side surface of the unit. The External Set-up Control Unit has the same switches as the Main Control PCB and works in the same way. It allows changes to be made without disassembling the unit. External Set-up Control Unit: MF/11 th April 2013/Issue 8 Page 7 of 12 The Micha Design Company Ltd

INPUT 2 INPUT 3 INPUT 4 3 INPUT 2 INPUT 3 INPUT 4 3 TB5 D1 D2 D3 D4 TR1 TR2 TR3 TR4 SW1 SW2 SW3 IC5 SW4 TB6 C2 TP1 IC3 IC4 IC6 TP2 TP7 LED5 R10 TP4 LED2 RN4 TP5 LED3 TP6 LED4 C3 C14 C13 IC9 C11 IC7 C12 IC8 PROGRAM PORT J4 C7 C9 C10 R8 XTAL1 IC2 SW8 RN1 RN3 C6 RN2 SW7 PSU1 SW10 R2 R4 C8 R6 BACK LIGHT C4 R3 R5 1 CONTRAST SW9 RED VE WHT -VE J1 R1 Micha Design Power Generation Display Unit 801309-8.doc 4. Drawings 4.1. Power Generation Display Unit - 42 x 30cm (A3) General Arrangement 426mm 70mm 12 4 x M6 DOME NUTS 6 x REAR ACRYLIC FIXINGS EARTH STUD 4 x BACK BOX FIXINGS REAR PERSPEX - WITH CUT-OUT FOR GRAPHICS DISPLAY FRONT PERSPEX - NO CUT-OUT 1 HOLE FOR POSSIBLE CABLE ENTRY GENERATION DISPLAY UNIT PCB ASSEMBLY MDC 401 221 EARTH NEUTRAL LIVE F1 SUPPLY PCB BEZEL BACK BOX SP NO COM SP NO COM SP NO COM SP NO COM INPUT 1 1 2 1 2 3 1 2 3 1 2 3 R1 8 R1 1 R1 9 R1 2 R1 6 R1 5 R2 5 R2 0 R2 6 R2 1 R2 2 R2 3 COUNTR Y OF ORIGIN: U.K. Micha R1 3 R1 4 SW6 SET RUN PN: 401195 ISSUE J3 GENERATION CONTROL PCB ASSEMBLY DOWN R2 7 R2 4 R1 7 MENU UP J2 VR1 SELECT GRAPHICS DISPLAY PCB 303mm 250mm CONTROL PCB 4 x M16 BLANKING PLUGS EXTERNAL SET-UP CONTROL UNIT CONNECTOR 15 4.2. Power Generation Display Unit - 42 x 30cm (A3) Back Box Mounting Details GENERATION DISPLAY UNIT PCB ASSEMBLY MDC 401 221 EARTH NEUTRAL LIVE R1 F1 PSU1 250mm 180mm SP NO COM SP NO COM SP NO COM SP NO COM INPUT 1 1 2 1 2 3 1 2 3 1 2 3 TB5 D1 D2 D3 D4 R11 R12 R15 TR1 R18 R19 R16 TR2 R20 R21 R23 TR3 R25 R26 R22 SW1 SW2 SW3 IC5 SW4 TB6 C2 TP1 IC3 IC4 TP2 TP4 TP5 TP6 LED5 R10 LED2 RN4 LED3 LED4 C3 C14 C13 IC9 SW6 C12 IC8 PROGRAM PORT J4 R13 R14 C11 IC7 C9 C7 C10 R8 XTAL1 SET TR4 IC6 TP7 RUN PN: 401195 ISSUE GENERATION CONTROL PCB ASSEMBLY SUPPLY PCB Micha COUNTRY OF ORIGIN: U.K. R27 R24 R17 J3 IC2 MENU SW8 DOWN RN1 RN2 RN3 R2 R4 C6 UP SW7 SW10 C8 R6 BACK LIGHT C4 VR1 R3 R5 J2 CONTRAST 1 SW9 RED VE WHT -VE SELECT J1 GRAPHICS DISPLAY PCB CONTROL PCB 330mm 370mm MF/11 th April 2013/Issue 8 Page 8 of 12 The Micha Design Company Ltd

4.3. Power Generation Display Unit - 42 x 30cm (A3) Graphic Design Detail (Overall) 13mm 8mm A A 134.0 mm 303mm 261mm 227.0 mm 120.0 mm 1st LINE TEXT AREA 2nd LINE TEXT AREA 90.0 mm SEE DRAWING 501647 FOR DISPLAY DETAIL. ACRYLIC SHEET IS 422MM X 299MM 3rd LINE TEXT AREA 8mm 13mm A A 13 8 384mm 8 13 426mm 4.4. Power Generation Display Unit - 42 x 30cm (A3) Graphic Design Detail (Text) HOLE IN GRAPHIC FOR DISPLAY 3mm 1st LINE TEXT AREA 23mm 6mm 90mm 2nd LINE TEXT AREA 23mm 6mm 3rd LINE TEXT AREA 23mm 120mm 6mm MF/11 th April 2013/Issue 8 Page 9 of 12 The Micha Design Company Ltd

INPUT 2 INPUT 3 INPUT 4 3 TB5 INPUT 2 INPUT 3 INPUT 4 POWE R GENERATION DIS PLAY UNIT PCB ASSEMBLY MDC 401 221 D1 R11 R12 R15 TR1 D2 R18 R19 R16 TR2 D3 R20 R21 R23 TR3 D4 R25 R26 R22 3 SW2 SW3 SW4 TB5 TB6 C2 TP1 TP2 SW1 IC3 IC4 IC5 F1 TP4 TP5 TP6 LED5 R10 LED2 RN4 LED3 LED4 C3 PSU1 C14 C13 SW6 IC9 TR1 TR2 TR3 TR4 C11 IC7 C12 IC8 PROGRAM PORT J4 R13 R14 C9 C7 C10 SW1 SW2 SW3 IC5 SW4 TB6 C2 TP1 IC3 IC4 IC6 R17 XTAL1 SET TR4 IC6 TP7 RUN PN: 401195 ISSUE J3 GENERATION CONTROL PCB ASSEMBLY R8 TP2 TP7 TP4 TP5 TP6 IC2 MENU SW8 LED5 R10 LED2 RN4 LED3 LED4 DOWN C3 PSU1 C14 RN1 C13 C6 RN2 RN3 UP SW7 SW10 IC9 C11 IC7 R2 R4 C12 IC8 C8 R6 R1 LIGHT BACK C4 PROGRAM PORT J4 C7 C9 C10 R3 R5 J2 CONTRAST SW9 RED VE WHT -VE 1 SELECT XTAL1 J1 IC2 SW8 RN1 RN2 RN3 SW7 SW10 R2 R4 C8 R1 BACK LIGHT C4 R3 R5 1 CONTRAST SW9 RED VE WHT -VE J1 Micha Design Power Generation Display Unit 801309-8.doc 4.5. Power Generation Display Unit - 60 x 50cm General Arrangement 605mm 73mm 15mm 4 x M8 DOME NUTS REAR PERSPEX - WITH CUT-OUT FOR GRAPHICS DISPLAY 8 x M16 BLANKING PLUGS FRONT PERSPEX - NO CUT-OUT 4 x BACK BOX FIXINGS EARTH STUD EARTH SUPPLY PCB NEUTRAL LIVE BEZEL SP NO COM SP NO COM SP NO COM SP NO COM INPUT 1 1 2 1 2 3 1 2 3 1 2 3 Mi cha COUNTRY OF ORIGIN: U.K. R27 R24 VR1 GRAPHICS DISPLAY PCB 505mm 300mm BACK BOX CONTROL PCB 4 HOLES FOR POSSIBLE CABLE ENTRY 8 x REAR ACRYLIC FIXINGS EXTERNAL SET-UP CONTROL UNIT CONNECTOR 15mm 4.6. Power Generation Display Unit - 60 x 50cm Back Box Mounting Details 8 x 16.0 mm DIAMETER GLAND HOLE 15.0mm 450.0mm 420.0mm 120.0mm 120.0mm 120.0mm 4 x 5.0 mm DIAMETER BACK BOX FIXING HOLE SUPPLY PCB EARTH STUD GENERATION DISPLAY UNIT PCB ASSEMBLY MDC 401 221 EARTH NEUTRAL LIVE F1 4 x 61.5 mm DIAMETER CABLE ENTRY HOLE 100.0mm SP NO COM SP NO COM SP NO COM SP NO COM INPUT 1 1 2 1 2 3 1 2 3 1 2 3 D2 D1 R18 R11 R19 R12 R16 R15 D4 D3 R25 R20 R26 R21 R22 R23 COUNTRY OF ORIGIN: U.K. Micha R13 R14 R8 R17 SW6 SET RUN PN: 401195 ISSUE J3 GENERATION CONTROL PCB ASSEMBLY DOWN R27 R24 MENU C6 UP R6 VR1 J2 SELECT GRAPHICS DISPLAY PCB 250.0mm 300.0mm CONTROL PCB 50.0mm 25.0mm 52.5mm 32.5 140.0mm 140.0mm MF/11 th April 2013/Issue 8 Page 10 of 12 The Micha Design Company Ltd

4.7. Power Generation Display Unit - 60 x 50cm Graphic Design Details 16mm BEZEL INNER OUTLINE OUTLINE OF ACRYLIC SHEETS HOLES: 4 OFF 9.0 mm DIAMETER DIMENSIONS: 205mm BEZEL OUTER: 505 x 605 mm BEZEL INNER: 445 x 545 mm ACRYLIC SHEET: 500 x 600 mm 500mm 90mm 468mm HOLE IN GRAPHIC FOR DISPLAY 205mm 16mm 16 568mm 16 374 mm 120mm 106mm 600mm 4.8. Power Generation Display Unit - 60 x 50cm Graphic Design Detail (Text) HOLE IN GRAPHIC FOR DISPLAY 3mm 1st LINE TEXT AREA 23mm 6mm 90mm 2nd LINE TEXT AREA 23mm 6mm 3rd LINE TEXT AREA 23mm 120mm 6mm MF/11 th April 2013/Issue 8 Page 11 of 12 The Micha Design Company Ltd

5. Software 5.1. Software History Software Version Date Released Comments Ver 1.0 Ver 1.1 Ver 1.2 Ver 1.3 Ver 1.4 Ver 1.5 Ver 1.6 22 nd Aug 2006 First Production Software 23 rd Aug 2007 Change CO2 factor from 0.43 to 0.568 9 th Nov 2007 Modifications to Settings Screen Layout Refresh screen every 5 seconds 19 th Nov 2007 Settings Screen: Pulse Value now adjustable from 1-9 units (For multiple building use assuming all units producing same power) 24 th June 2008 Default for Instant Power Update Time changed to 2 minutes 1 st Oct 2009 Settings Screen: Pulse Value Units can now be adjusted from 1-40 11 th April 2013 Added new Line 4 on Settings Menu as a reminder to the user (Press SELECT to update Total Energy) MF/11 th April 2013/Issue 8 Page 12 of 12 The Micha Design Company Ltd