ELECTRONIC CONTROLS & SENSORS. AK-SC255 Fact Sheet Version R Software Software version 02_085

Similar documents
MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

AK-SC255 Fact Sheet & Recommended Accessories List

REFRIGERATION AND AIR CONDITIONING. On Site Guide AK2-SC 255

System User Manual. AKC 55 Rack Controller

MAKING MODERN LIVING POSSIBLE AK-SC255. Software Release E Version. Supplement Manual ELECTRONIC CONTROLS & SENSORS

Protocol interface AK-PI 300

Protocol interface AK-PI 200 REFRIGERATION AND AIR CONDITIONING. Manual

Refrigeration Notes ECI upgrade process

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

MAKING MODERN LIVING POSSIBLE AK-SC255. Software Release VR2.191 R Version ELECTRONIC CONTROLS & SENSORS. Supplement Manual

Refrigeration and Air Conditioning Controls. Technical Leaflet. Monitoring, Control and Alarm System m2 REFRIGERATION AND AIR CONDITIONING

Installation guide. Data communication link to m2 - LON with EKC - LonWorks

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

MCX08M2 Programmable controller

Installing and Setting Up the Components

TALON Network Manager- 2 & 6 Express

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

AK-System Manager AK-SM 800 Series

BACnet Controller for General-purpose Building Applications

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

AK-System Manager AK-SM 800

Installing VO2 Analog Output Boards

AK-System Manager AK-SM 800

Specification Sheet For electronically commutated motors

Extended Digital Controller

Installation and configuration. WebAccess and its modules for ECL Comfort 200 / 300

EP/2 Installation Instructions

Quick Start Installation Guide

ECL Comfort V a.c. and 24 V a.c.

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel

RTU32S RTU32S Series Small Compact Utility RTU

RTU32S RTU32S Series Small Compact Utility RTU

General information. Display. Supply voltage

AC 800M for Compact Product Suite Outline of all modules

PAC BI-DP BIM and 8701-CA-BI Carrier

NEUROLOGIC RESEARCH CORPORATION MODEL 2150

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

TM241CE40R controller M IO relay Ethernet

General information. Display. Supply voltage

EP-ELVCTL Elevator Control (NION-16C48M)

BCM2 Series Branch Circuit Monitors Quick Setup Guide

Submittal Data Sheet WAGO Node for itm

clarity 3 Programmable Controller

Andover ContinuumTM Infinet II

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

TM241CE24T controller M IO transistor PNP Ethernet

General information. Display. Supply voltage

TM241CE40R controller M IO relay Ethernet

CAS Danfoss AK-SC-255 XML Interface Modbus (RTU and TCP) and BACnet and HTML Gateway

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

General information. Display. Supply voltage. Input current

BUILDING MANAGEMENT. OpenBAS-HV-NX10 SERIES CATALOG NUMBER. Description. Features

TWDLCAE40DRF compact PLC base Twido V AC supply - 24 I 24 V DC - 16 O

SonoMeter 30 Ultrasonic energy meter for heating and cooling applications

H704-42(H)(E), H704-42/1(H)(E)

TM241CE40R controller M IO relay Ethernet

General information. Display. Supply voltage. Input current. Encoder supply. Output current

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

BACnet. b3810 Series Local Controllers

AO561 Analog Output Module

Andover ContinuumTM Infinet II

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable

Data sheet. MCX15B electronic controller MAKING MODERN LIVING POSSIBLE. REFRIGERATION & air CONDITIONING DIVISION. Danfoss Electronics spa

MIC-2 MKII, Multi-instrument DATA SHEET

General information. Display. Supply voltage. Input current

Wiring Guide EP.HIO. Version 1.03 Last Updated:

COSMOS COLLECTOR X10 COSMOS X10 DATA COLLECTION AND REPORTING SYSTEM. User manual

TM241CE24U controller M IO transistor NPN Ethernet

CM597 Ethernet Communication Module

EXOcompact Third Generation Manual

TM241CEC24R controller M IO relay Ethernet CAN master

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Multi-Point Gas Detection and Control System

Programmable controller MCX152V

TWDLCDE40DRF compact PLC base Twido - 24 V DC supply - 24 I 24 V DC - 16 O

TM172PBG42R Modicon M172 Performance Blind 42 I/Os, Ethernet, Modbus

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

JNIOR Series 4 A Network I/O Resource Utilizing the JAVA Platform Getting Started Manual Release 2.0 NOTE: JANOS OS 1.1 or greater required

TM241CE24T controller M IO transistor PNP Ethernet

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

General information. Display. Supply voltage. Input current

VersaMax Micro and Nano Technical Product Presentation

General information. Display. Supply voltage. Input current. Encoder supply. Output current

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company

TM241CE40T controller M IO transistor PNP Ethernet

TM241C40R controller M IO relay

General information Engineering with Programming package. Display with display

Web server. Simplified.

General information. Display. Supply voltage. Input current. Encoder supply. Output current

TWDLCAE40DRF compact PLC base Twido V AC supply - 24 I 24 V DC - 16 O

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

Description Front View of SSC-0025 Rear View of SSC-0025

General information. Display. Supply voltage. Input current. Encoder supply. Output current

TWDLCAE40DRF. Main. Range of product

Transcription:

ELECTRONIC CONTROLS & SENSORS AK-SC255 Fact Sheet Version R Software Software version 02_085

What s in the Box? 1x AK-SC255 (either Box or DIN rail screen-less version) What are the different part numbers? 080Z2000 AK-SC255 Box, Color, TP78 Refrigeration 080Z2001 AK-SC255 Box, Color, TP78 Lighting, HVAC 080Z2002 AK-SC255 Box, Color, TP78 Refrigeration, Lighting, HVAC 080Z2082 AK-SC255 No Display TP78, Refrigeration, Lighting, HVAC Recommended Individual Controller capacity(s) per AK-SC255 - Generic + I/O Type Capacity Configuration Type AK2-CC303a 60 Max configured evap sections 150 or Type EKC (SNMP, Lonworks) 99 1 controller per evap section Recommended Remote AK2 I/O capacity or General purpose devices (Wattnode, Access I/O...) (In addition to controllers) AK2 CM (Communication Module) 10 AK2 I/O 64 points Analog (General I/O, HVAC, Lighting) AK2 I/O 64 points Digital (General I/O, HAVC, Lighting) Recommended Individual Controller capacity(s) per AK-SC255 - Centralized 255 I/O Type Capacity Configuration AK2 I/O 256 points Analogue / Digital Inputs and AK2 I/O 256 points Digital Output Recommended Remote AK2 I/O capacity or General purpose devices (Wattnode, Access I/O...) (In addition to controllers) AK2 CM (Communication Module) 30 Max Nodes (inc AK2 CM) 120

Available Network Protocols Ethernet Port (used for LAN/WAN network connections, host network, remote AKA65 software tool) RS485 Host Bus (Host network - multiple AK-SC255 units OR EKA 167 Modbus Display) RS232 Port (used for local AKA 65 software tool connection) Modem Port (used for serial modem) LonWorks TP78 (used for AK I/O modules) Power KWh Meter Pulse input capacity AK2-XM107A Pulse Module, Max 80 inputs Expansion Capacity (host network) Max 10 AK-SC255 units in host network formation History Data points 600 History Capacity 8 MB System processor & memory PowerPC CPU 64MB dynamic RAM UL Listed File number E166834

Remote connection software AKA65 v5.2 : Modem Ethernet Serial Current Supported Controller devices In order to correctly manage control devices, specific controller support files known as EDF files are required in the AK-SC255. The list below describes all the current controllers the AK-SC255 will support out of the box. This list will continue to grow with additional controller support added on a regular basis. Controllers not on this list can also be accommodated in the AK-SC255 but will be issued on a restricted basis via the factory and will remain as beta until factory & field tests have been completed. Recommended Modem Support Zoom V.92 56k Modem (Model 3049) AKA 231 Phoenix modem Environmental Data Operating temperature 32 to 104 F (0 to +40 c) @ 95% RH (non condensing) 32 to 122 F (0 to +50 c) @ 0 to 90% RH (non condensing) Storage temperature -4 to 122 F (-20 to +50 c)

Mounting screw locations, general dimensions 8.00 (203.2 mm) Serial Port Mounting and Wiring The mounting location should be flat, dry and free from major vibrations. The AK-SC255 should be mounted at eye level, with consideration for the following approximate outline dimensions: Unit Width 10.5 (266 mm) Unit Height 12.5 (317 mm) Unit Depth 2.5 (63 mm) Mounting holes 8.0 (203.2 mm) Width Mounting holes 10.00 (254 mm) Height 10.00 (254 mm) To allow the door to fully open, ensure that there is an area at least 21 (533 mm) x 11 (280 mm) free, leaving room for conduit connections beneath the controller. Mount the controller using appropriate screws through the holes indicated at left, fastening the back of the controller enclosure securely to the flat surface chosen. Allow approx 3 (76 mm) for side access to local connection port (Danfoss cable part # 080Z0262) 3/4 (19 mm) Knockout 1 (25 mm) Knockout Internal component layout With the controller door open, the two main sections of the AK-SC255 can be seen, Base board & Connector board. 20.34 (516.34 mm) 10.16 (258 mm) Base board Mounted on the door frame is the Base board with the main CPU card. The base board contains the following important components that need to be set for correct system operation: Battery (shipped in disabled position) Type CR2032 with (+) side facing toward the user. Engage battery circuit to ensure data is protected after power loss - set Jumper JP5 as follows. JP5 JP5 (battery jumper) System address switch & JP3 / JP4 CR2032 CPU Card Reset button Host RS485 / Modbus Network The AK-SC255 system utilizes a selectable RS485 / Mod bus port (located on Connector board). The unit comes factory set as Modbus communications. To enable RS485 Host network, jumpers JP3 & JP4 need to be set. Note that if Modbus is used, RS485 host is not available - set host to Ethernet in AK-SC255 software. JP3 JP4 JP3 & JP4 not connected = RS485 Host JP3 & JP4 connected = EKC Modbus System address switch Rotary address switch to set AK-SC255 address Address 0 = Master (1-9 for Slave units) Internal Component layout (Base board) System Reset button Use the CPU reset button to reset the AK-SC255 5

Connector Board - User Connections Internal component layout cont. Connector board The Connector board contains the main user connection ports needed for communications, relay output and power supply: Ethernet Standard RJ45 Ethernet port, used for TCP/IP remote connection (LAN,WAN), SNMP network support & Host network. Use Ethernet as Host network if Virtual Display functionality is required. Ethernet External Modem Port Output relay RS485 / Modbus Lonworks Communication Power Supply RS485 Host network / Modbus See table below for jumper settings Use the RS485 port either for RS485 Host or EKC Modbus communications. For RS485 Host communications, use 2 conductor shield cable. Up to 10 AK-SC255 controllers can be connected in a host network. Host / Modbus network options JP3 & JP4 Notes RS485 Host OFF Used when combining AKC55 / 255 on host 120 Ohm terminator to be on 1st & last unit EKC Modbus ON (factory set) Use for EKC Modbus controllers 120 Ohm terminator to be on last controller only If host network required use Ethernet Ethernet Host N/A Use Ethernet port and connect to LAN Configure in Communications section Lonworks I/O Network (TP78) External Modem Modem port used in conjunction with Modem Adapter kit 080Z2100 Relay Rated at 30V d.c. 1Amp. Used for external alarm signal. AK-I/O Modules.. 6 AK-I/O Modules Terminator Terminator Generic Controller devices AK & EKC controllers Lonworks I/O Network The I/O (Input-Output) network uses Echelon Lon Talk communications. Depending on AK-SC255 version, up to five I/O network cables can be connected to each AK-SC 255. When connecting A and B conductors, there is no polarity to observe for AK I/O modules. For more information about connecting I/O cables, and restrictions on their length and layout, consult the AK-SC255 Reference Manual. Attach a terminator to each set of unused I/O terminals. For Generic networks (EKC & AK controllers) it is recommended only to use one of the five ports available. Follow network wiring regulations for each of the different network types. For additional information on networks consult Danfoss document entitled Data communication between ADAP-KOOL Refrigeration Controls (RC8AC302)

Functionality Overview Networks EKC controller IP network support EKC / AK2 controller RS485 network support EKC controller Modbus network support AK Input / Output network HVAC, AHU & Roof Top Unit control Central control or via RTC (roof top controller) Lighting control 30 lighting zones 6 relays per zone Standard or relative schedules 8 schedules per zone Auto override for burglar or fire alarm Switch override with override box Photo Cell support & integration Miscellaneous Points 96 Misc Boolean Logic statements per AK-SC255 64 Misc relay DO per AK-SC255 48 Misc VO per AK-SC255 10 Misc Conversion factors 64 Misc sensor inputs & ON/OFF inputs - monitoring & alarm Alarm routing Modem / GSM TCP/IP Relay Security 8 Auth levels 66 account codes Screen Type VGA high res colour History Data points 600 (per AK-SC255) History Capacity 10 minute samples on 120 points = 1 year

www.danfoss.us ADAP-KOOL Refrigeration Control Systems is a trademark of Danfoss A/S, www.danfoss.com Danfoss can accept no responsibility for possible errors in catalogs, brochures, or other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. AK-SC255 'R' Fact Sheet (Version B1) DKRCE.PD.R1.B1.22 / 520H3579 Danfoss 07-2009