Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

Similar documents
Process displays For current and voltage

02/11/2015

Time Counters mini "h", DC Version

Tachometers TC-4B-V TC-6A-V Electronic cam-operated switching devices FC-21-V... 50

Chapter. In This Chapter...

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

DIGITAL DISPLAY. for Industry Applications. Series WAY-D. Key-Features:

POSICHRON PCQA Mounting Sets

GS202 Encoder Switch

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Product Description. Contents. Fusion Series. New Information December 2003

DIGITAL DISPLAY. for Industry Applications. Serie REX-D. Key-Features:

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

Absolute encoders - SSI

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

Access Terminal IF-800

Model Number Structure

H7BX CSM_H7BX_DS_E_4_4

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

signo 727 SSI operating instructions

Counting On Your Process Preset Counters

02/11/2015

G60 SERIES ELECTRONIC PRESET COUNTER ESC P1 / P2 SHIFT RESET ENT

Displays Transducers. Displays and transducers

LVX Control Unit. Features:

Electronic SD1, AS 8, ASR 14, ASR 20

02/11/2015

Amplifiers, Counters, Timers & Controls

DX 345, DX 346, DX 347, DX 348

Inductive Proximity Sensor

FEMA ELECTRÓNICA. Series MAG983-X. COUNTERS for IMPULSE signals MAG983-1 MAG983-2 MAG983-3 MAG USER S MANUAL (HT0695-r050705)

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Chip Immune Inductive Prox E2EZ

KTC. Preset Counter/ Timer. Programmable Type. Model Number Legend SALIENT FEATURES. Sensing. Digital Panel Meters

Batch Controller with numerical keypad and receipt printer driver

SYSMAC Remote Transistor Module

Photoelectric Sensors E3F2

signo 727 SSI Operating Instructions Position-Indicator with/without limit values and SSI input from absolute encoder

Temperature Switches

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing

DX 342. Multi Function Counters with 2 Presets, 2 Relay Outputs and Serial RS 232 / RS 485 Interface. Operating Instructions. control motion interface

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features

Universal counter UZ 9648 Counting - length measurement - metering - positioning

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

Process controllers for the meat processing industry

20 General technical data XI/ON

Multifunction Counter/Tachometer H7CX Series

Assembly. Front view. LED yellow: Relay output I. LED yellow: Relay output II

TC 34 MICROPROCESSOR-BASED DIGITAL ELECTRONIC COUNTER

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

TIMERS FOR ALL APPLICATIONS

7511 / / / 711 / / 731 / Preset 27

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

CoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A...

Faults on the system Proximity switch connection technology:

Panel Mount Tachometer, T6

Inductive Proximity Sensor

Syr-line TMR48D Digital Timer

KS 3012 PMA GENERAL DESCRIPTION

02/11/2015

Vision OPLC. Technical Specifications. V T34 Technical Specifications

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

KCN-S/KCN-W. Merits. Single/Dual Preset Counters for Addition and Subtraction. Electronic. Counters

General information. Display. Supply voltage. Input current

H3CA-8H-AC/100/110/120

Indicomp 4 Bargraph Indicator

Solid-state Counter. Power supply Output No voltage input (short/open circuit) Voltage input (high/low voltage) 30 cps 1 kcps 30 cps 1 kcps AC

General information. Display. Supply voltage. Input current. Encoder supply. Output current

DMW. Digital Weighing Meter. Model Number Legend SALIENT FEATURES. Sensing

SmartSlice. System Configuration

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

Technical specifications

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

405A Timer with Instantaneous Relay

Energetic diffuse reflection light scanner. Dimensioned drawing

Hints for Replacement of Obsolete Controller Models BY240 with New Models BY340

Sensing method Appearance Connection method Sensing distance Part number NPN output PNP output Through-beam Prewired (2 m) E3Z-T61A E3Z-T81A 10 m

Model Number Structure

User friendly and easy to program

Special-Purpose Photoelectric Sensors

Speed switches Programmable, digital speed switch With incremental encoder POG 10

08/07/2015

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

Digital Keypad Introduction

Syr-line TMR48D Digital Timer

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

4. Sensing Distance. 2: 2 mm. 4: 4 mm 8: 8 mm 15: 15 mm 16: 16 mm 20: 20 mm

the Interactive Catalog

Model Number Structure

DIGITAL PANEL THERMOMETER

Interface Relay CRINT-1x

Accessories. Measuring wheels Order designations. Measuring wheel with 20 cm circumference (small)

Optical Absolute Encoder Singleturn or Multiturn with hollow shaft Profibus-DP, CAN, CANopen, DeviceNet GX, G1, G2AMH / GX, G1, G2MMH

Thread length (overall length) material

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

Transcription:

Electronic Preset Counter with 2 Presets and Print interface NE21 Prog. 09 Features Order designation Order no. Interface RS22 Models Connection Functions LED-preset counter with 2 presets Batch counter or Tachometer Totalizer, Time meter Incremental encoder One-channel, digital sensor 2 one-channel, digital sensors for difference counting Start count programmable Scaling factor programmable 0.0001...99.9999 Batch counter with one preset and multiplier (1...99) Print interface RS22 Printout can be activated via F- key or signal input Programmable preset mode: - Step preset - Main preset - Parallel comparison - Drag preset (P1) NE21. Decription AX09 Outputs 1 With relay, batch counter normally closed 2 With relay, batch counter normally open Electronic outputs PNP 4 Electronic outputs NPN Supply voltage 1 24 / 48 VAC 2 115 / 20 VAC 24 VDC The NE21 program 09 is based on the preset counter NE212 with an additional print routine. This print function makes it possible to print several lines of the NE21 as well as texts and any control character with one print instruction. The connected printer can be activated via the function key or the external input. The programming of the print protocol is done by means of a print manager program, whereby the data are transmitted via the serial interface RS22. If a print protocol has been programmed, it will be output to the printer. Otherwise the currently displayed value will be printed. Mechanical data Display 7-segment LED-display 8-digit display of real value, 7.6 mm high Programmable decimal point Display suppression of preceding zeroes - Minus sign for negative values Operation, keypad Front membrane with shortstroke keys Front dimensions DIN housing, 72 x 72 mm Mounting Front panel with U-clips Weight AC: approx. 450 g DC: approx. 20 g Connection Plug-in screw terminals Grid 5.08 mm Core cross-section Max. 1.5 mm 2 Housing material Macrolon 6485 (PC) black, UL 94V-0 Keypad membrane Polyester material 102 www.ivo.de

NE21 Prog. 09 Block diagram Electrical data Supply voltage Signal inputs Reset Stop / Hold A B 2 12 1 14 15 A 90 B Totalizer Main counter with 2 presets Set value Scaling factor 4 5 6 7 8 9 P1 P2 Supply voltage Power consumption Sensor supply Choice of two voltages (AC) via switch on device. 115 ±10% / 20 VAC +6 %/ -10 % (50 / 60 Hz) 24 / 48 VAC ±10 % (50 / 60 Hz) 24 VDC ±10 %, 5 % residual ripple 6 VA, 6 W 12...26 VDC / max. 100 ma XB-signal input XB-reset Coding for input logic NPN Br. 18-20 PNP Br. 18-19 Serial interface 16 17 18 TxD 2 24 RxD 25 26 GND Batch counter as preselection counter with 1 preset multiplier tachometer or batch counter Operating time meter Interface RS22 10 11 19 20 B1 Sensor supply Signal inputs Input counting rate Optocoupler inputs Count inputs A / B - control current 9...16 ma - breaking current <0.5 ma - input resistance 1.65 kohm Control inputs - control current 5...8 ma - breaking current <0.5 ma - input resistance. kohm PNP-, NPN-logic can be coded via wire jumper to terminal strip 15 Hz, 25 Hz, 10 khz programmed Control inputs control inputs for reset, stop, hold, etc. Signal outputs Programmable as momentary or permanent signals; Impulse time can be programmed 0.01...99.99 s Relay signal outputs 2 floating center-zero relays for main counter 1 floating relay for batch counter, to be programmed as normally open or closed Internal spark quenching Max. switch. voltage 250 VAC Max. switch. power 1 A Max. swit. capacity 150 VA/0 W Electronic signal outputs NPN switching transistor - Max. switching voltage +5 V - Max. switching power 50 ma PNP switching transistor - Max. switching voltage 12...24 VDC with AC operation, depending on load - Max. switching power 50 ma, for DC operation - Max. switching power 10 ma, for AC operation Reset Manually, electrically or automatically Data storing > 10 years via EEPROM www.ivo.de 10

Electronic Preset Counter with 2 Presets and Print interface NE21 Prog. 09 Pin assignments for relay output 26 25 24 2 22 21 20 19 18 17 16 15 14 1 12 +24V 0V Sensor supply NPN Br. 18-20 PNP Br. 18-19 XB reset XB counter XP-stop/ h-timer XP reset B A Count Counting mode of signal inputs A / B Up/Down Difference, A - B Total, A + B Phase, A 90 B x1 Phase, A 90 B x2 Phase, A 90 B x4 11 10 9 8 7 6 5 4 2 1 Ambient conditions B1 P2 P1 max. 250 V Terminal - Terminal / - Terminal Pin assignments for electronic output Supply Ambient temperature 0...+50 C Storage temperature -20...+70 C Relative humidity Max. relative humidity 80 %, at 25 C, non-condensing Protection Front IP 65 to DIN 40050 General rating EN 61010 Part 1 - Protection standard II - Overvolt. protection categ. II - Contamination factor 2 Interference immunity EN 50082-2 Emitted interference EN 50081-1 26 25 24 2 22 21 20 19 18 17 16 15 14 1 12 +24V 0V Sensor supply NPN Br. 18-20 PNP Br. 18-19 XB reset XB counter XP-stop/ h-timer XP reset B A Count Contact descriptions programming cable 9-pins, D-SUB 4-pins Colour Function socket insert 11 10 9 8 7 6 5 4 2 1 2 2 brown TxD 25 blue RxD 5 26 black GND B1 P2 Output P1 Supply max. 250 V Terminal - Terminal / - Terminal Contact descriptions print cable 25-pins, D-SUB 4-pins Colour Function socket insert 2 25 blue RxD 2 brown TxD 7 26 black GND Pin assignments for interface applications 26 25 24 2 GND RxD TxD RS22 Accessories Order no. Z 118.041 Programming cable Z 118.042 Print cable Z 118.04 Print manager program Incremental encoder (see Encoder catalog) 104 www.ivo.de

NE21 Prog. 09 Display and keypad Display LEDsymbol display Shift key for function display 10er keypad Shift key for programming/operating mode Reset key C Sign key Function key (start print) Dimensions 72 18.5 108 105 Gasket 72 67.7 Cutout 68 +0.7 x 68 +0.7 mm 1-6 7 www.ivo.de 105

Electronic Preset Counter with 2 Presets and Print interface NE21 Prog. 09 Settings of Dip switch NE21 Dip no. Switch ON 2, 7 Switch OFF 1,, 4, 5, 6, 8, 9, 10 Print Manager Description The print manager enables a print protocol to be created on the PC by means of an editor. The protocol is transmitted via the serial interface RS22 to the NE21 and is stored there. After the transmission of the protocol, the connection to the printer is established at the same interface. The printer can be activated manually via the NE21 or by an electric signal. Print protocol A print protocol consists of all characters that are sent to the connected printer by the IVO counter upon activating the print function. These signs are grouped as follows: control characters, text characters, counter data Control characters Control characters are all characters that serve to control or to configure the printer, e.g. changing over to condensed type, line feed, paper feed, etc. For further information see printer manual. Example: 27 87 1 (changing over to expanded type) Text characters Text characters are characters that correspond to the input in the editor and that are output in the printout. Text characters are marked by inverted commas. Example: length= Counter data Counter data are display values of the IVO counter. To select the requested values, one only has to enter the respective line number with curly brackets in the editor. Example: {02} (preset P2) Example 27 1 'Ta. length =' {0} 'cm' 10 Counter data 'Length =' {02} 'cm' 10 27 11 Counter data 106 www.ivo.de

NE21 Prog. 09 www.ivo.de 107