INSTRUCTIONS FOR LED INDUSTRIAL LIGHTING LIGHT STRIPS AND WORK LIGHTS

Similar documents
WLS28-2 Dual Color LED Strip Light

WLC60 Heavy Duty Stainless Steel LED Light

WLS27 Dual Color LED Strip Light

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

LED..O..M Series Diffused On-Axis Lights

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

WLB32 Industrial LED Light Bar (DC)

AEXX-349 SERIES REMOTE DISPLAYS

EZ-LIGHT SP Series Signal Light

B/W PAN/TILT FIXED DOME CAMERA

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

AE21 SERIES DISPLAY CONTROL TERMINAL

Brasch Washdown Unit Heaters

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

Global Water Instrumentation, Inc.

AEXX-273 SERIES WIRELESS CONTROLLED PACE CLOCKS

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

User s Guide. OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

AirPro Surveyor 2 Manual

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

Instruction Manual. Balanced Audio Upgrade Installation. iport IW-21/IW-22 Upgrade Kits. Balanced Audio Upgrade Kit. (iport IW-21)

VIP-480AL IP One-Way Horn

PixController, Inc. Wireless Switch Sensor For Normally Open (NO) and Normally Closed (NC) Sensors

ivu TG Gen2 Image Sensor with Integrated Display

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasIED.com

SafePace 600 Variable Messaging Sign

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

TSD-SEQ6 Sequencer Controller

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

TB-100 ControLynx Terminal Block

PMDX-170 Slotted Optical Sensor

Aluminum-detecting Proximity Sensor (Separate Amplifier Type)

Gateway Module Programmable in C

OPERATIONS MANUAL PCM-DOC

DC425 NEMA 4X Analog Output Transducers

V-9939B MICROPHONE ADAPTER

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF

Remote Control for Inverter RC-300. Owner's Manual. Please read this manual BEFORE operating your RC-300 Remote Control

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

C Mb Ethernet Copper Tap

Woolich Racing. USB ECU Interface User Guide

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

User Guide. Control Box. RoscoLED TM.

HVPS-C. High Voltage Power Supply. HVPS-C. Package Contents: Sold Separately. Table of Contents:

TDM-150 TIMER DISPLAY

NMEA2000 DC MONITOR Part Numbers: 3410 USER MANUAL

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Operating Manual RISH DPM Hz

TSD-DA28 2x8 Balanced Line Distribution Amplifier

SERVICE MANUAL MODEL SSW-520-F

Specifications 1 Installation Procedures 2 Wiring Diagrams 3 Installation Checklist 5 Maintenance 5 Warranty Information 6 Material Return Policy 6

Installation and User Guide

Hybrid AC Driver [GCNC-1110]

Data Reporter. Installation-Operation E rev.f

Owner s Manual. TSD-ZDC Audio Impedance Combiner/Divider. TSD-ZDC Audio Impedance Combiner/Divider

SERVICE MANUAL MODEL SSW-321-F MODEL BLW-321-F

MFJ ENTERPRISES, INC.

Benchmark Plus Microplate Reader User Manual. This Instrument for Laboratory Use Only Rev C

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

MWR30. INSTALLATION/OWNER S MANUAL Wired Remote Control MARINE

Model 206 Operating Instructions. Setra Systems, Inc. 159 Swanson Road, Boxborough, MA

Control Mount Instruction Manual CM-IW200

User s Guide. POWERVAR Single Phase Power Conditioners

STAINLESS STEEL CAST FITTINGS 150lb 304 & 316 Stainless Steel Cast Fittings Specifications

Piccola Smart Box Member of Modul MAS family

DOCKING STATION FOR THE APPLE 13 MacBook

SVP48 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

IE-MediaChassis/1. Operation Manual

MODEL A12 OWNER S GUIDE A-SERIES ENVIRONMENT-PROOF HIGH-OUTPUT/LONG-THROW LOUDSPEAKER

LLTOUCHDX4 - PRODUCT INFORMATION

AC4G-D User s Manual

SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

PixController, Inc. Wireless Magnetic Switch Sensor For Doors, Windows, and Gates

Indicator (Square) Ultra Bright LED Type

OPERATION MANUAL SERIES BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

20W Tungsten-Halogen Light Source. Operation Manual

DCM Digital Control Modules

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

PCM-7140 Pulsed Current Source Operation Manual

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

poly-planar Marine Audio System

Xxxxx Xxxxxx OM-CP-QUADVOLT. OM-CP-OCTVOLT 8-Channel Low Level DC Voltage Data Logger. 4-Channel Low Level DC Voltage Data Logger INSTRUCTION SHEET

SECURE/NONSECURE LED SIGN USER MANUAL

SERVICE MANUAL MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE. and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE

OPERATION MANUAL BO BLASTER S OHMMETER

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.

Owner s Manual. TSD-RL21 2x1 Mic/Line Mixer. TSD-RL21 2x1 Mic/Line Mixer with Remote Level

Rack Power Distribution Unit AP7530, AP7540

DICKSON FH320/325 & FT300/325 DICKSON. Temperature/Humidity Recorder. Specifications. Applications & Product. Product. Contents: Getting Started

Transcription:

INSTRUCTIONS FOR LED INDUSTRIAL LIGHTING LIGHT STRIPS AND WORK LIGHTS These lights use extremely bright, cool white, energy-efficient LEDs and are effective in directing the light to the work area. Light strips are ideal for use on machines, in control panels, cabinets, enclosures, and for industrial work areas. Light strips are available for environmental protection ratings of IP50, IP67, and IP68 and are offered as stand-alone light strips and cascading systems. Work lights are ideal for compact industrial lighting where space is limited. The flexible arm has unlimited adjustment possibilities and directs the light where needed. Environmental Rating IP50 Dustproof LED Light Strips Environmental Rating IP67 Dustproof Water resistant Environmental Rating IP68 Dustproof Suitable for harsh environments Protected up to 1200 PSI Stand Alone Stand Alone Standard Cascading Standard...pp. 2-5 Heavy-Duty...pp. 6-9 Cascading Standard...pp. 10-11 Heavy-Duty...pp. 12-13 Heavy-Duty Standard...p. 14 Heavy-Duty...p. 15 Work Lights LED Work Lights... pp. 16-17 Copyright 2017 by. All rights reserved. Not to be reproduced in whole or in part without written permission. Litho in U.S.A. 4620 Hydraulic Road Rockford, Illinois 61109-2695 Toll-Free 1-800-922-7533 Phone 815-874-7891 Fax 815-874-6144 Web Site www.rockfordsystems.com E-Mail sales@rockfordsystems.com Instruction Manual No. KSL-289

SECTION 1 IP50 STANDARD LIGHT STRIPS IP50 Standard Light Strips Stand-Alone and Cascading STAND-ALONE CONNECTION Optional Connection Cable Stand-Alone Light In-Line On/Off Switch STANDARD LIGHT STRIPS STAND ALONE/FIRST IN CASCADING* Part No. Length of Lighted Lumens Max. Current Per Length Surface 12 V DC 24 V DC 30 V DC LS-5 5.71 (145 mm) 325 0.5 A 0.25 A 0.2 A LS-11 11.22 (285 mm) 650 0.75 A 0.375 A 0.3 A LS-16 16.93 (430 mm) 975 1.25 A 0.625 A 0.5 A LS-22 22.44 (570 mm) 1300 1.5 A 0.75 A 0.6 A LS-27 27.95 (710 mm) 1625 2.0 A 1.0 A 0.8 A LS-33 33.46 (850 mm) 1950 2.25 A 1.125 A 0.9 A LS-38 38.98 (990 mm) 2275 2.75 A 1.375 A 1.1 A LS-44 44.49 (1130 mm) 2600 3.0 A 1.5 A 1.2 A *Mounting brackets included CASCADING CONNECTION Two or More Lights With Optional Accessories Optional Connection Cable Connection Cable Stand-Alone/ First In Cascading Second (or more) Cascading Light (See chart for current limitations.) In-Line On/Off Switch STANDARD LIGHT STRIPS CASCADING* MAXIMUM CURRENT LIMITATIONS Part No. Length of Lighted Lumens Max. Current Per Length Surface 12 V DC 24 V DC 30 V DC LSC-5 5.71 (145 mm) 325 0.5 A 0.25 A 0.2 A LSC-11 11.22 (285 mm) 650 0.75 A 0.375 A 0.3 A LSC16 16.93 (430 mm) 975 1.25 A 0.625 A 0.5 A LSC-22 22.44 (570 mm) 1300 1.5 A 0.75 A 0.6 A LSC-27 27.95 (710 mm) 1625 2.0 A 1.0 A 0.8 A LSC-33 33.46 (850 mm) 1950 2.25 A 1.125 A 0.9 A LSC-38 38.98 (990 mm) 2275 2.75 A 1.375 A 1.1 A LSC-44 44.49 (1130 mm) 2600 3.0 A 1.5 A 1.2 A *Mounting brackets included Input Voltage Maximum Cascadable Light Length 12 V 59 (1500 mm) 24 V 118 (3000 mm) 30 V 122 (3100 mm) 2 Call 1-800-922-7533

SECTION 1 IP50 STANDARD LIGHT STRIPS SPECIFICATIONS STANDARD LIGHTS Supply Voltage... 12 V to 30 V DC Color Temperature...Cool white (5,000-8,300 K) Construction...Anodized aluminum housing,...clear acrylic window Mounting Brackets... (2) zinc-plated steel brackets included Operating Temperature... -13 to 158 F (-25 to 70 C) Relative Humidity...90% (non-condensing) Storage Temperature... -40 to 158 F (-40 to 70 C) DIMENSIONS STANDARD LIGHT STRIPS Call 1-800-922-7533 3

SECTION 1 IP50 STANDARD LIGHT STRIPS CONNECTION CABLES Dimensions IN-LINE ON/OFF SWITCH PART NO. SWMDL-4 Dimensions SPECIFICATIONS Supply Voltage...30 V DC max. Current Rating...4 A max. Mounting Brackets... 2) zinc plated steel...brackets included 4 Call 1-800-922-7533

110 V AC POWER SUPPLY PART NO. PWR-4A Accepts universal AC input voltage (90 to 264 V AC) provides 24 V DC output Includes 4.9 (1.5 m) AC input cable SECTION 1 IP50 STANDARD LIGHT STRIPS Do not use in wet areas. 24 V TO 30 V DC POWER SUPPLY HARD-WIRED Part No. CD-72 CD-180 CD-360 Cable Lengths 72 (1.83 m) cable 180 (4.5 m) cable 360 (9 m) cable Call 1-800-922-7533 5

SECTION 2 IP50 HEAVY-DUTY LIGHT STRIPS IP50 Heavy-Duty Light Strips Stand-Alone and Cascading STAND-ALONE CONNECTION Optional Connection Cable Stand-Alone Light In-Line On/Off Switch HEAVY DUTY STAND ALONE/FIRST IN CASCADING Part No. Length of Lighted Lumens Max. Current Per Length Surface 12 V DC 24 V DC 30 V DC LH-10 10.02 (254.6 mm) 1300 1.4 A 0.7 A 0.56 A LH-20 20.38 (517.6 mm) 2600 3.1 A 1.53 A 1.22 A CASCADING CONNECTION Two or More Lights With Optional Accessories Optional Connection Cable Connection Cable Stand-Alone/ First In Cascading Second (or more) Cascading Light (See chart for current limitations.) In-Line On/Off Switch HEAVY DUTY CASCADING LIGHT(S) Part No. Length of Lighted Lumens Max. Current Per Length Surface 12 V DC 24 V DC 30 V DC LHC-10 10.02 (254.6 mm) 1300 1.4 A 0.7 A 0.56 A LHC-20 20.38 (517.6 mm) 2600 3.1 A 1.53 A 1.22 A BRACKETS Flat Brackets FKT-919 Set of two flat stainless steel brackets with flathead screws for mounting to the light. MAXIMUM CURRENT LIMITATIONS Maximum Number of Units Input Voltage 10.02 20.38 (254.6 mm) (517.6 mm) 12 V 3 1 24 V 6 3 30 V 8 4 Swivel Mount Brackets FKT-920 Set of two right-angle stainless steel brackets with buttonhead screws for mounting to the light. 6 Call 1-800-922-7533

SECTION 2 IP50 HEAVY-DUTY LIGHT STRIPS SPECIFICATIONS HEAVY-DUTY LIGHTS Supply Voltage...12 V to 30 V DC Color Temperature...Cool white (5,000-8,300 K) Construction... Nickel-plated aluminum housing, clear polycarbonate window Mounting Brackets...Sold separately see bracket options on previous page Operating Temperature...-40 to 122 F (-40 to 50 C) Relative Humidity... 90% (non-condensing) Storage Temperature...-40 to 158 F (-40 to 70 C) DIMENSIONS HEAVY-DUTY LIGHT STRIPS LH-10 AND LHC-10 (10.02 [254.6 MM]) DIMENSIONS HEAVY-DUTY LIGHT STRIPS LH-20 AND LHC-20 (20.38 [517.6 MM]) Call 1-800-922-7533 7

SECTION 2 IP50 HEAVY-DUTY LIGHT STRIPS CONNECTION CABLES Dimensions IN-LINE ON/OFF SWITCH PART NO. SWMDL-4 SPECIFICATIONS Supply Voltage...30 V DC max. Current Rating...4 A max. Mounting Brackets...(2) zinc-plated steel brackets included Dimensions 8 Call 1-800-922-7533

SECTION 2 IP50 HEAVY-DUTY LIGHT STRIPS 110 V AC POWER SUPPLY PART NO. PWR-4A Accepts universal AC input voltage (90 to 264 V AC) provides 24 V DC output Includes 4.9 (1.5 m) AC input cable Do not use in wet areas. 24 V TO 30 V DC POWER SUPPLY HARD-WIRED CABLE LENGTHS Part No. CD-72 CD-180 CD-360 Description 72 (1.83 m) cable 180 (4.5 m) cable 360 (9 m) cable Call 1-800-922-7533 9

SECTION 3 IP67 STANDARD LIGHT STRIPS IP67 Standard Light Strips Stand-Alone and Cascading STAND-ALONE CONNECTION Stand-Alone Light STANDARD LIGHT STRIPS STAND ALONE/FIRST IN CASCADING* Part No. Length of Lighted Lumens Max. Current Per Length Surface 12 V DC 24 V DC 30 V DC LS-5 5.71 (145 mm) 325 0.5 A 0.25 A 0.2 A LS-11 11.22 (285 mm) 650 0.75 A 0.375 A 0.3 A LS-16 16.93 (430 mm) 975 1.25 A 0.625 A 0.5 A LS-22 22.44 (570 mm) 1300 1.5 A 0.75 A 0.6 A LS-27 27.95 (710 mm) 1625 2.0 A 1.0 A 0.8 A LS-33 33.46 (850 mm) 1950 2.25 A 1.125 A 0.9 A LS-38 38.98 (990 mm) 2275 2.75 A 1.375 A 1.1 A LS-44 44.49 (1130 mm) 2600 3.0 A 1.5 A 1.2 A *Mounting brackets included CASCADING CONNECTION Two or More Lights With Hard-Wired Connection Cable Stand-Alone/ First In Cascading Second (or more) Cascading Light (See chart for current limitations.) STANDARD LIGHT STRIPS CASCADING* MAXIMUM CURRENT LIMITATIONS Part No. Length of Lighted Lumens Max. Current Per Length Surface 12 V DC 24 V DC 30 V DC LSC-5 5.71 (145 mm) 325 0.5 A 0.25 A 0.2 A LSC-11 11.22 (285 mm) 650 0.75 A 0.375 A 0.3 A LSC16 16.93 (430 mm) 975 1.25 A 0.625 A 0.5 A LSC-22 22.44 (570 mm) 1300 1.5 A 0.75 A 0.6 A LSC-27 27.95 (710 mm) 1625 2.0 A 1.0 A 0.8 A LSC-33 33.46 (850 mm) 1950 2.25 A 1.125 A 0.9 A LSC-38 38.98 (990 mm) 2275 2.75 A 1.375 A 1.1 A LSC-44 44.49 (1130 mm) 2600 3.0 A 1.5 A 1.2 A *Mounting brackets included Input Voltage Maximum Cascadable Light Length 12 V 59 (1500 mm) 24 V 118 (3000 mm) 30 V 122 (3100 mm) 10 Call 1-800-922-7533

SECTION 3 IP67 STANDARD LIGHT STRIPS CONNECTION CABLES Dimensions SPECIFICATIONS STANDARD LIGHTS Supply Voltage... 12 V to 30 V DC Color Temperature...Cool white (5,000-8,300 K) Construction...Anodized aluminum housing,...clear acrylic window Mounting Brackets... (2) zinc-plated steel...brackets included Operating Temperature...-13 to 158 F (-25 to 70 C) Relative Humidity...90% (non-condensing) Storage Temperature... -40 to 158 F (-40 to 70 C) DIMENSIONS STANDARD LIGHT STRIPS 24 V TO 30 V DC POWER SUPPLY HARD-WIRED CABLE LENGTHS Part No. CD-72 CD-180 CD-360 Description 72 (1.83 m) cable 180 (4.5 m) cable 360 (9 m) cable Call 1-800-922-7533 11

SECTION 4 IP67 HEAVY-DUTY LIGHT STRIPS IP67 Heavy-Duty Light Strips Stand-Alone and Cascading STAND-ALONE CONNECTION Stand-Alone Light Brackets HEAVY DUTY STAND ALONE/FIRST IN CASCADING Part No. Length of Lighted Lumens Max. Current Per Length Surface 12 V DC 24 V DC 30 V DC LH-10 10.02 (254.6 mm) 1300 1.4 A 0.7 A 0.56 A LH-20 20.38 (517.6 mm) 2600 3.1 A 1.53 A 1.22 A CASCADING CONNECTION Two or More Lights With Hard-Wired Connection Cable Stand-Alone/ First In Cascading Brackets Second (or more) Cascading Light (See chart for current limitations.) Brackets HEAVY DUTY CASCADING LIGHT(S) Part No. Length of Lighted Lumens Max. Current Per Length Surface 12 V DC 24 V DC 30 V DC LHC-10 10.02 (254.6 mm) 1300 1.4 A 0.7 A 0.56 A LHC-20 20.38 (517.6 mm) 2600 3.1 A 1.53 A 1.22 A BRACKETS Flat Brackets FKT-919 Set of two flat stainless steel brackets with flathead screws for mounting to the light. MAXIMUM CURRENT LIMITATIONS Maximum Number of Units Input Voltage 10.02 20.38 (254.6 mm) (517.6 mm) 12 V 3 1 24 V 6 3 30 V 8 4 Swivel Mount Brackets FKT-920 Set of two right-angle stainless steel brackets with buttonhead screws for mounting to the light. 12 Call 1-800-922-7533

CONNECTION CABLES Dimensions SECTION 4 IP67 HEAVY-DUTY LIGHT STRIPS SPECIFICATIONS HEAVY-DUTY LIGHTS Supply Voltage... 12 V to 30 V DC Color Temperature...Cool white (5,000-8,300 K) Construction...Nickel-plated aluminum housing,...clear polycarbonate window Mounting Brackets... Sold separately see bracket...options on previous page Operating Temperature...-40 to 122 F (-40 to 50 C) Relative Humidity...90% (non-condensing) Storage Temperature... -40 to 158 F (-40 to 70 C) DIMENSIONS HEAVY-DUTY LIGHT STRIPS LH-10 AND LHC-10 (10.02 [254.6 MM]) DIMENSIONS HEAVY-DUTY LIGHT STRIPS LH-20 AND LHC-20 (20.38 [517.6 MM]) 24 V TO 30 V DC POWER SUPPLY HARD-WIRED Part No. CD-72 CD-180 CD-360 Cable Lengths 72 (1.83 m) cable 180 (4.5 m) cable 360 (9 m) cable Call 1-800-922-7533 13

SECTION 5 IP68 WASHDOWN LIGHT STRIPS IP68 Washdown Light Strips Standard Stand-Alone Light STANDARD WASHDOWN LIGHT STRIPS* Part No. Length of Lumens Max. Current Per Length Lighted Surface 12 V DC 24 V DC 30 V DC LS-5 5.71 (145 mm) 325 0.5 A 0.25 A 0.2 A LS-11 11.22 (285 mm) 650 0.75 A 0.375 A 0.3 A LS-16 16.93 (430 mm) 975 1.25 A 0.625 A 0.5 A LS-22 22.44 (570 mm) 1300 1.5 A 0.75 A 0.6 A LS-27 27.95 (710 mm) 1625 2.0 A 1.0 A 0.8 A LS-33 33.46 (850 mm) 1950 2.25 A 1.125 A 0.9 A LS-38 38.98 (990 mm) 2275 2.75 A 1.375 A 1.1 A LS-44 44.49 (1130 mm) 2600 3.0 A 1.5 A 1.2 A *Mounting brackets included SPECIFICATIONS STANDARD LIGHTS Supply Voltage...12 V to 30 V DC Color Temperature... Cool white (5,000-8,300 K) Construction...Anodized aluminum housing, clear acrylic window Mounting Brackets... (2) zinc-plated steel...brackets included Operating Temperature... -13 to 158 F... (-25 to 70 C) Relative Humidity... 90% (non-condensing) Storage Temperature... -40 to 158 F...(-40 to 70 C) DIMENSIONS STANDARD 24 V TO 30 V DC POWER SUPPLY WASHDOWN HARD-WIRED Part No. CDSS-6 CDSS-15 CDSS-30 Cable Lengths 6 (1.83 m) stainless steel hard wire cable 15 (4.5 m) stainless steel hard wire cable 30 (9 m) stainless steel hard wire cable 14 Call 1-800-922-7533

IP68 Washdown Light Strips Heavy-Duty SECTION 5 IP68 WASHDOWN LIGHT STRIPS Stand-Alone Light HEAVY-DUTY WASHDOWN LIGHT STRIPS Part No. LH-10 LH-20 Length of Lighted Surface 10.02 (254.6 mm) 20.38 (517.6 mm) Lumens Brackets Max. Current Per Length 12 V DC 24 V DC 30 V DC 1300 1.4 A 0.7 A 0.56 A 2600 3.1 A 1.53 A 1.22 A SPECIFICATIONS HEAVY-DUTY LIGHTS Supply Voltage... 12 V to 30 V DC Color Temperature...Cool white (5,000-8,300 K) Construction...Nick el-plated aluminum housing,...clear polycarbonate window Mounting Brackets... Sold separately see bracket...options below Operating Temperature...-40 to 122 F (-40 to 50 C) Relative Humidity...90% (non-condensing) Storage Temperature... -40 to 158 F (-40 to 70 C) DIMENSIONS HEAVY-DUTY LH-10 (10.02 [254.6 mm]) LH-20 (20.38 [517.6 mm]) BRACKETS Flat Brackets FKT-919 Set of two flat stainless steel brackets with flathead screws for mounting to the light. Swivel Mount Brackets FKT-920 Set of two right-angle stainless steel brackets with buttonhead screws for mounting to the light. 24 V TO 30 V DC POWER SUPPLY WASHDOWN HARD-WIRED Part No. CDSS-6 CDSS-15 CDSS-30 Cable Lengths 6 (1.83 m) stainless steel hard wire cable 15 (4.5 m) stainless steel hard wire cable 30 (9 m) stainless steel hard wire cable Call 1-800-922-7533 15

SECTION 6 WORK LIGHTS Work Lights WLX-000 IP67 WLP-000 IP50 Work lights are ideal for compact industrial lighting where space is limited. These work lights use an industrial grade, 18 flexible arm to direct the light where needed with unlimited adjustment possibilities. Work lights are available as a direct mount light with power supply with plug (110 V AC input to 24 V DC output), or as a hard-wired (12 V to 30 V DC) direct mount light. An optional clamp for mounting is available for both. SPECIFICATIONS WORK LIGHTS Supply Voltage...12 V to 30 V DC Current Draw...400 ma max. Color Temperature... Cool white (5,000-8,300 K) Lumens...285 Construction... Black anodized aluminum housing, polycarbonate window Mounting... 18 vinyl coated, flexible steel, direct mount arm Operating Temperature...-40 to 122 F (-40 to 50 C) Relative Humidity...90% (non-condensing) Storage Temperature...-40 to 158 F (-40 to 70 C) WLX-000 ENVIRONMENTAL RATING IP67 18 direct-mount arm work light with 5 (1.5 m) hard-wired cable (12 V to 30 V DC). WLC-000 Optional Clamp Converts direct-mount base to a clamp-style base. 16 Call 1-800-922-7533

WLP-000 ENVIRONMENTAL RATING IP50 SECTION 6 WORK LIGHTS 18 direct-mount arm work light with 5 (1.5 m) cable, connector, power supply with plug (110 V AC input to 24 V DC output), and in-line On/Off switch. WLC-000 Optional Clamp Converts the direct-mount base to a clamp-style base. REPLACEMENT PARTS FOR WLP-000 IN-LINE ON/OFF SWITCH PART NO. SWMDL-4 SPECIFICATIONS Supply Voltage...30 V DC max. Current Rating...4 A max. Mounting Brackets... 2) zinc plated steel...brackets included 24 V DC, 1 AMP POWER SUPPLY PART NO. PWR-1A Converts 110 V AC to 24 V DC 72 (1.83 m) cable with wall plug Call 1-800-922-7533 17

SECTION 7 REPLACEMENT PARTS REPLACEMENT BRACKETS FKT-918 Set of two stainless steel replacement brackets with screws for mounting. These replacement brackets are for standard light strips and for the in-line On/Off switch. CONNECTION CABLES Part No. CDE-12 CDE-35 CDE-72 CDE-144 CDE-240 CDE-359 CDE-598 Cable Length 12.2 (.31 m) connection cable 35.8 (.91 m) connection cable 72.0 (1.83 m) connection cable 144.1 (3.66 m) connection cable 240.2 (6.10 m) connection cable 359.9 (9.14 m) connection cable 598.6 (15.2 m) connection cable SPECIFICATIONS CONNECTION CABLES AC Voltage/Current...250 V/4 A DC Voltage/Current...250 V/4 A Minimum Temperature...-40 F (-40 C) Maximum Temperature...221 F (105 C) Environmental Rating... IP67 Make allowance of at least 2 on each side of a connection cable if the application calls for bending of the cables. This will prevent the cables from kinking. Do not spray cables with a high-pressure sprayer or cable damage will result. Warranty, Disclaimer, and Limitation of Liability WARRANTY warrants that this product will be free from defects in material and workmanship for a period of 12 months from the date of shipment thereof. ROCKFORD SYSTEMS, LLC s OBLIGATION UNDER THIS WARRANTY IS EXPRESSLY AND EXCLUSIVELY LIMITED to repairing or replacing such products which are returned to it within the warranty period with shipping charges prepaid and which will be disclosed as defective upon examination by. This warranty will not apply to any product which will have been subject to misuse, negligence, accident, restriction and use not in accordance with Rockford Systems, LLC s instructions or which will have been altered or repaired by persons other than the authorized agent or employees of. s warranties as to any component part is expressly limited to that of the manufacturer of the component part. DISCLAIMER The foregoing Warranty is made in lieu of all other warranties, expressed or implied, and of all other liabilities and obligations on the part of Rockford Systems, LLC, including any liability for negligence, strict liability, or otherwise, and any implied warranty of merchantability or fitness for a particular purpose is expressly disclaimed. LIMITATION OF LIABILITY Under no circumstances, including any claim of negligence, strict liability, or otherwise, shall be liable for any incidental or consequential damages, or any loss or damage resulting from a defect in the product of. KSL289/0717