Accessories / 7XV5461

Similar documents
Accessories / 7XV5662

Accessories / 7XV5820

HARTING econ 3000 Introduction and features

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

Fibre Optic and Wireless Solutions

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

Industrial Switches. 9 Industrial. Industrial Switch, 5 Ports 100Base-TX 554 Industrial Switch, 8 Ports 100Base-TX 555

HARTING Ha-VIS mcon 3000 Next Generation Full managed Ethernet PROFINET Switch

PSI-MOS-RS422/FO 850 T

7XV5103 RS485 Bus Systems up to 115 kbit/s (not suitable for PROFIBUS)

PSI-MOS-PROFIB/FO 850 T

Converter Box Data Sheet

CMU 100 RS485 to Ethernet Converter User Manual CMU 100 / CMU 100 / 1.M.9 CMU 100 / 1.L.9 CMU 100 / CMU 100 / 7.M.9 CMU 100 / 7.L.

Industrial Switches Industrial Switches

Manual Fiber Optic Interfaces

Industrial 3-Port Fast Ethernet Media Converter Switches

WaveLine managed switches with IOs

SCB-C08 USB to RS232/422/485 Converter

Published by and copyright 2015 Siemens AG Energy Management Freyeslebenstr Erlangen, Germany

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

FL MC 2000E (SM40) LC

Features and Benefits. Certifications

ACP 1703 Ax 1703 CM Fieldbus Interface Ring (3x FO, 1x el.)

Features and Benefits. Certifications

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

PSI-MOS-PROFIB/FO 850 T

RightWON Satellite Ethernet switch module (ESM), multi-mode

HARTING scon Introduction and features

PTC-101 Quick Installation Guide

Extract from the online catalog

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

RS-232 / RS-422 / RS-485 over Fast Ethernet Media Converter

Fibre Modem - Single-mode

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

Switches with management functions. Active components Introduction Managed switches

Features and Benefits. Certifications

Dymec Serial Links. SubStation Hardened RS232 Serial Copper to Fiber Link/Repeaters. Features

SIPROTEC 3/4 central operation via Ethernet Serial-Hub

ADAM Fiber Optic to RS-232/422/485 Converter

Industrial Media Converters

7SG18 Solkor N Numeric Differential Protection

SIPROTEC 5 Application Note. Breaker-and-a-half solutions. SIP5-APN-002, Edition 2.

SIPROTEC 4 7SS52 Distributed Numerical Busbar and Breaker Failure Protection

Ha-VIS econ 2000 Fast and Full Gigabit Ethernet Basic. Features

Manufacturer Description

PT-7728/7828 Quick Installation Guide

Media Converters. Media Converters. Product Selection Guides

RS-232 Industrial Media Converter

Fiberoptic G.703 Codir - IEEE C37.94 converter, Technical manual. Technical Manual 90_20_0101_r2.doc

RTU560 Connections and Settings DIN Rail RTU 560CIG10

MED102A. Industrial Serial to Single-mode Fiber Converter

Features and Benefits. Certifications

FL MC 10/100BASE-T/FO-660

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Entry Line Industrial Gigabit Ethernet Bridging Converter, PoE+ optional 1x 10/100/1000Base-T, 1x 100/1000 SFP

RTU560 Remote Terminal Unit Connections and Settings

VCL-TP, Teleprotection Equipment

IMC-21GA Quick Installation Guide

UPGRADE AND APPLICATION OF AUTOMATION SYSTEM IN T.S. 110/35/10 KV PETROVEC

MGate MB3170/MB3270 Quick Installation Guide

IM IM in the RS485 variants features: 9-pin Sub-D socket for connection to PROFIBUS DP

ICF-1150 Series Quick Installation Guide

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS. KC-300DM Series. Installation Guide

H3C SecPath M9000-S NSQM2MPUD0 main processing unit

IMC-P111FX / IMC-P111P Series

PTC-101-M12 Hardware Installation Guide

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

RS 232 to Fibre Optic Modems ELO E240, ELO E241, ELO E242. Operation manual

INDUSTRIAL POE SWITCH

Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide

THE SOLUTION. MFW product family OPERATING INSTRUCTIONS. Modular optical fibre telecontrol system. Application-ready systems from the

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

OPERATOR MANUAL OSD156 SYNCHRONOUS FIBER OPTIC RS232 MODEM

KFC-200. Installation Guide

PLIN-LWL Optical Coupler for LIN Data Transmission. User Manual. Document version ( )

SIPROTEC 4 7SA522 Distance Protection Relay for Transmission Lines

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4

Relays for Various Protection Applications / 7SV600

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS

6GK6091-0AT Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Serial Device Servers > RUGGEDCOM RS910 managed

Ha-VIS mcon 3000 Next Generation Introduction and features

Rugged MediaConverter

4 Channel Contact Closure DIN Fiber Link System

We Bring Light into the Dark. Reliable Differentiation also of Dark Colors.

KIS-MC M Media Converter

6GK6096-8AS Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RS900 managed

OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER

EDS-G205-1GTXSFP/G308 Series

ALMEMO NETWORK TECHNOLOGY

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

SINAUT ST7 Dedicated Line Modem MD2

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

Moxa Industrial Media Converter

imc2f Features Industrial IEC Ethernet to Fiber Media Converter Tel: Fax:

Transcription:

Accessories / XV XV two-channel serial optical repeater (for mono-mode FO cable) Fig. / Optical repeater with integrated 0 nm/ nm wave length multiplexer for one single mono-mode FO-cable LSP.tif Function overview Two independent multiplexed 0 nm Ports / with ST connectors for max.. km via 0/ μm and./ μm multi-mode FO cable. Data rate of serial Ports / from 00 bit/s.0 Mbit/s. Automatic baud rate adjustments to synchronous and asynchronous serial signals; no settings necessary. Powerful 0 nm/ nm port with LC-single connector for distances up to 0 km via one / μm mono-mode FO cable DC to 0 V and AC /0 V wide-range power supply with alarm relay. Data exchange display by LED Integrated commissioning support The optical repeater exchanges serial optical signals over long distances via only one single mono-mode FO cable. It converts serial optical 0 nm signals at Port and Port in the range 00 bit/s.0 Mbit/s to 0/ nm for one mono-mode FO cable. Both synchronous and asynchronous signals can be connected at Port /. Two independent, serial 0 nm inputs with ST connectors are available, which are multiplexed to Port. Two devices with an optical 0 nm interface, for example the SD/SD line differential protection relay or the RS/0 nm XV converter, can be connected to Ports and via multi-mode FO cables for distances of up to. km. Signal transmission at Port is achieved via the single LC connector at wavelengths of 0 nm / nm for connection of mono-mode FO cable up to 0 km. The device can be connected to DC battery voltages and AC supply sources. Loops can be activated for Port / for commissioning purposes, so that the input signals can be mirrored at each port to support commissioning of the fiber optical links. Siemens SIP Edition No. /

Accessories / XV Application, technical data Application Until now, two FO cables are required for the bidirectional transmission of protection signals. With the repeater with integrated wavelength multiplexer one FO cable is sufficient: Two protection relays e.g. SD/SD differential protection or SA/SA distance protection, exchange information via Port (po). Interference-free data exchange is performed via one optical mono-mode FO cable up to a max. distance of 0 km. Protection remote control with DIGSI is connected to Port of the repeater via a XV0 mini star-coupler. This port provides the serial connection to the other substation with a PC on which DIGSI is installed. In this way, the remote protection devices can be remotely interrogated via Port. The baud rate is optimally set to. kbit/s so that there is no difference from local operation. The data of the devices on the other substation can be changed or read out during commissioning and operation. Alternatively, it is possible to connect substation control devices, RTU or additional protection data transmission to Port. This makes for optimum use of the long-distance optical cable for two separate serial connections for transmitting serial data between 00 bit/s and.0 Mbit/s. Fig. / Transfer of protection data signals and remote control / integration via one mono-mode FO cable (Note: Devices XV-0BK00 and XV-0BL00 must be used in pairs) Technical data Connections Ports / ST connector for 0 nm for 0 / μm and./ μm multi-mode FO cable Port LC-single connector for 0 nm / nm for / μm mono-mode FO cable Screw-type terminals -pole screw-type terminals for auxiliary voltage supply -pole make/break contact for alarm relay Housing Interference-free mm metal housing for mounting on mm DIN rail to EN 00. Weight 0. kg. Degree of protection acc. to EN 0: IP Wide range DC to 0 V or AC / 0 V Displays LEDs Green Red yellow Alarm relays Data exchange indication / Siemens SIP Edition No.

Accessories / XV Selection and ordering data Order No. Two-channel serial optical repeater with integrated wavelength multiplexer XV - 0B 00 Connection of two serial optical inputs with ST connector for./ μm multi-mode FO cable up to. km, from 00 bit/s.0 Mbit/s 0 V DC, /0 V AC wide-range power supply Alarm relay and LED for operational and fault display Optical nm output with LC-single connector for / μm mono-mode FO cable for distances up to 0 km (permissible path attenuation db) K Optical 0 nm output with LC-single connector for / μm mono-mode FO cable for distances up to 0 km (permissible path attenuation db) L Siemens SIP Edition No. /

Accessories / XV /0 Siemens SIP Edition No.

Accessories / XV XV two-channel serial optical repeater (for duplex-mono-mode FO cables) Fig. / Optical repeater with wide-range power supply LSP0.tif Function overview Two independent multiplexed 0 nm ports with ST connectors for max.. km via 0 / μm and./ μm duplex-multi-mode FO cable. Data rate of serial ports / from 00 bit/s.0 Mbit/s. Automatic baud rate adjustment to synchronous and asynchronous serial signals; no settings necessary. Powerful 0 nm / nm port with LC-Duplex connector for distances up to km / 0 km / 0 km / km via / mm duplex-mono-mode FO cable DC to 0 V and AC /0 V wide-range power supply with alarm relay. Data exchange display by LED Integrated commissioning support The optical repeater transmits serial optical signals over long distances via duplex-mono-mode FO cables. It converts serial optical 0 nm signals at Port and Port in the range of 00 bit/s to.0 Mbit/s. Both synchronous and asynchronous signals can be connected. Two independent, serial 0 nm inputs with ST connectors are available, which are multiplexed to Port. Two devices with an optical 0 nm interface, for example the SD / SD line differential protection relay or the RS/ 0 nm XV converter, can be connected to Ports and via duplex-multi-mode FO cables for distances of up to. km. Signal transmission at Port is achieved via the LC-Duplex connector at wavelengths of 0 nm/ nm for connection of a duplex-mono-mode FO cable. For Port there are three options for max. km (0 nm) / 0 km (0 nm) and 0 km / km ( nm) optical fiber lengths. The device can be connected to all battery voltages and AC supply sources. Loops can be activated for Ports / for commissioning purposes, so that the input signals can be mirrored at the port in question. Siemens SIP Edition No. /

Accessories / XV Typical applications, technical data Typical applications The protection relays (for example SD / SD differential protection or SA / SA distance protection) exchange information via Port. Interference-free data exchange is performed via duplex-mono-mode FO cable up to a distance of km. Protection remote control with DIGSI is connected to Port of the repeater via the XV0 mini star-coupler. This port provides the serial connection to the other substation with a PC where DIGSI is installed. The protection relays on the remote substation can be scanned remotely via Port.The baud rate is optimally set to. kbit/s so that there is no difference from local operation. During commissioning and operation, data of the device on the other substation can be changed and read out. Alternatively, it is possible to connect power system control or additional protection data transmission to Port. This makes for optimum use of the long-distance optical fiber for two separate serial connections for transmitting data between 00 bit/s and.0 Mbit/s. LSA-cen.eps 0/ km Fig. / Transfer of protection data and remote control of a substation via an optical longdistance connection Technical data Connections Ports / ST connector for 0 nm for 0/ μm and./ μm multi-mode FO cable Port LC-Duplex connector for 0 nm/ nm for / μm mono-mode FO cable Screw-type terminals -pole screw-type terminals for auxiliary voltage supply -pole make/break contact for alarm relay Housing 0 mm aluminum housing for mounting on mm DIN rail to EN 00. Weight 0. kg. Degree of protection acc. to EN 0: IP Wide range to 0 V DC without connector jumpers, AC / 0 V Displays LEDs Green Red yellow Alarm relays Data exchange / Siemens SIP Edition No.

Accessories / XV Selection and ordering data Order No. XV two-channel serial optical repeater (for duplex-mono-mode FO cables) XV - 0B 00 Connection of two serial optical inputs with ST connector for./ μm multi-mode FO cable up to. km, from 00 bit/s to.0 Mbit/s to 0 V DC, /0 V AC wide-range power supply Fault relay and LED for operational and fault display Optical 0 nm output with LC-Duplex connector for / μm mono-mode FO cable for distances up to km (permissible path attenuation db) G Optical 0 nm output with LC-Duplex connector for / μm mono-mode FO cable for distances up to 0 km (permissible path attenuation db) Optical nm output with LC-Duplex connector for / μm mono-mode FO cable for distances up to 0 km (permissible path attenuation db) Optical nm output with LC-Duplex connector for / μm mono-mode FO cable for distances up to km (permissible path attenuation db) ) When ordering options H/J an additional attenuator is required if the devices are used for distances < 0 km H ) M J ) Siemens SIP Edition No. /

Accessories / XV / Siemens SIP Edition No.

Accessories / XV XV two-channel serial optical repeater (for duplex-multi-mode FO cables) Fig. / Optical repeater with wide-range power supply LSP0.tif Function overview Two independent multiplexed 0 nm ports with ST connectors for a max. of. km via 0 / μm and. / μm duplex-multi-mode FO cable. Data rate of serial Ports / from 00 bit/s. Mbit/s. Automatic baud rate adjustment to synchronous and asynchronous serial signals; no settings necessary. Powerful 0 nm port with LC-Duplex connector for distances up to km / km via 0/ mm /./ mm duplex-multimode FO cable DC to 0 V and AC /0 V wide-range power supply with alarm relay. Data exchange display by LED Integrated commissioning support with test loop feature The optical repeater transmits serial optical signals over long distances via duplex-multi-mode FO cables. It converts serial optical 0 nm signals at Port and Port in the range 00 bit/s. Mbit/s to 0 nm for duplex-multi-mode fiber cables. Both synchronous and asynchronous signals can be connected. Two independent, serial 0 nm inputs with ST connectors are available, which are multiplexed to Port. One transmit (Tx) and one receive (Rx) signal is supported (no RTS / CTS handshake signals). Two devices with an optical 0 nm interface, for example the SD / SD line differential protection relay or the RS/0 nm XV converter, can be connected to Ports and via duplex-multi-mode FO cables for distances of up to. km. Signal transmission at Port is achieved via the LC-Duplex connector at wavelengths of 0 nm for connection of a duplex-multi-mode FO cable. For Port there are two options for a max. of km (0 nm) and km (0 nm) optical fiber lengths. The device can be connected to all battery voltages and AC supply sources. Loops can be activated for Ports / for commissioning purposes, so that the input signals can be mirrored at the port in question. Siemens SIP Edition No. /

Accessories / XV Typical applications, technical data Typical applications Two protection relays (for example SD/SD differential protection or SA/SA distance protection) exchange information via Port. Interference-free data exchange is performed via optical duplex-multi-mode FO cable up to a distance of / km. Protection remote control with DIGSI is connected to Port of the repeater via XV0 mini star-coupler. This port provides the serial connection to the other substation with a PC where DIGSI is installed. The protection relays on the remote substation can be interrogated remotely via Port. The baud rate is optimally set to. kbit/s so that there is no difference from local operation. During commissioning and operation, the data of the device in the other substation can be changed and read out. Alternatively, it is possible to connect a substation control system or additional protection data transmission to Port. This makes for optimum use of the longdistance optical fiber for two separate serial connections for transmitting data between 00 bit/s and.0 Mbit/s. Fig. / Transfer of protection data and remote control of a substation via an optical long-distance connection Technical data Connections Ports / ST connector for 0 nm for 0/ μm and./ μm multi-mode FO cable Port LC-Duplex connector for 0 nm for 0/ μm /./ μm multi-mode FO cable Screw-type terminals -pole screw-type terminals for auxiliary voltage supply -pole make/break contact for alarm relay Housing 0 mm aluminum housing for mounting on mm DIN rail to EN 00. Weight 0. kg. Degree of protection acc. to EN 0: IP Wide range to 0 V DC without connector jumpers, AC / 0 V Displays LEDs Green Red yellow Alarm relays Data exchange / Siemens SIP Edition No.

Accessories / XV Selection and ordering data Order No. Two-channel serial optical repeater (for duplex multi-mode FO cables) XV - 0B 00 Connection of two serial optical inputs with ST connector for./ μm multi-mode FO cable up to. km, from 00 bit/s to. Mbit/s DC to 0 V, AC /0 V wide-range power supply Fault relay and LED for operational and fault display Optical 0 nm output with LC-Duplex connector for 0/ μm /./ μm multi-mode FO cable for distances up to km (permissible path attenuation db) F Optical 0 nm output with LC-Duplex connector for 0/ μm /./ μm multi-mode FO cable for distances up to km (permissible path attenuation db) E Siemens SIP Edition No. /