PT9232. Heavy Industrial RS232 Communication

Similar documents
PT9DN. Heavy Industrial DeviceNET

PT8CN. CANbus SAE J1939 Output Signal

SGJ Cable Actuated Sensor Industrial CANBus J1939

SR1H Cable Actuated Sensor Industrial CANOpen Output Signal

SKH. CANOpen Output Signal. Linear Position to 400 inches (10 m) Compact Design Simple To Install User Adjustable Measuring Cable Orientation

SGH. SGH inch stroke range, no terminating resistor 5-pin M12 mating plug, mounting bracket. CANopen Output Signal SGH-80-4-TR

SGH Cable Actuated Sensor Industrial CANOpen

Contents. Volume 8 Sensing Solutions CA E January V8-T3-61

Optical Encoders. Sold & Serviced By: Toll Free Phone: Toll Free Fax:

3.3. Inductive Proximity Sensors. Contents Description. E57PS Performance Short Body Sensors. E57PS Performance Short Body Sensors..

DIGITAL ANEMOMETER Model : AM-4203

APPLICATION NOTES. Connectors for LED Lighting Applications. Co-Planar Board Mating FIG. 1

4-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection

Product Manual MNX10043 REV A MODEL DSB. Dual Sensor Modular Switch box

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

8-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection

How to connect ALPHA signs to DeviceNet

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches

T E M P O S O N I C S I I I INSTALLATION CAUTION! B. CONNECTORS RG Connector. D6 Connector: INTEGRAL CABLE P Integral Cable

Features. Sensing range 50 mm mm... Type of light. Light source 3) Wave length. Adjustment 2) PL80A.

Compact Coded Magnetic Safety Interlock Switch and Control Units

Industrial enclosures. Unparalleled time savings and improved reliability with a new generation of vibration monitoring enclosures

OPERATION MANUAL. SD card real time datalogger, RS232/USB VIBRATION METER. Model : VB-8206SD

Description. Specifications and Ordering Information 9200, 74712, Seismoprobe Velocity Transducer System

General-Purpose Photoelectric Sensor

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

and High Temperature Velomitor * System

VIBRATION METER Model : VB-8213

T E M P O S O N I C S I I I INSTALLATION

Rotary Measurement Technology Absolute Encoders, Multiturn

and High Temperature Velomitor * System

D730. Remote Display Installation Manual

ECV ecompass Series. Technical Brief. Rev A. Page 1 of 8. Making Sense out of Motion

Universal Tongue-Operated Safety Interlock Switch

GE Industrial Solutions. DET-756 Installation Instructions ASPMETER Panelboard Monitoring System

High Voltage DC Meter

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

Installation and Operation Guide

Product description. At a glance. Your benefits

Data Sheet for Linear Sensors

Miniature Inductive Prox TL-W

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

Manual. Technical Specifications: Version 1.0.0, May Copyright Terabee 2016

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

ML17 Series Tru-Vue TM Sensors

AC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

HIGH-VOLTAGE DC METER

Sidewinder Pumps Inc. AC Timer/Controller

TECHNICAL DATASHEET Absolute Encoder AC 58 - CANlayer2

Special-Purpose Proximity Sensor E2C

Product description. At a glance. performance in a metal housing coating available Precise autocollimation optics. sensors

C5 Series Stainless Steel Photoelectric

A2K. Absolute Optical Encoder: Kit Version Page 1 of 7. Description. Features

HG4930 INERTIAL MEASUREMENT UNIT (IMU) Installation and Interface Manual

600 g x 0.02 g DIGITAL BALANCE

Chapter. In this Chapter... Safety Guidelines Introduction Panel Cutout Dimensions (all models) Wiring Guidelines...

Piston rod cylinder Guide cylinders Series MSN. Brochure

LED LIGHT METER OPERATION MANUAL. Model : LX-1148SD. SD card real time Data Recorder 10 Light Source select, Auto range 0 to 50,000 LUX

Effective range ABS AT505A ABS AT524 AT527

Rotary Measuring Technology

ToughSonic Distance Sensors

HTZ. Description. Features. Smart HART Humidity and Temperature Transmitter

Rotary Measurement Technology Absolute Encoders, Singleturn

More Precision. wiresensor // Draw-wire displacement sensors

NL-01 NL-01. The NL-01 InoxLaser uses time-offlight laser technology for continuous non-contact distance or level measurement.

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview

4.2 Expansion Modules MAC00-B1/B2/B4

Draw wire sensors, draw wire sensors for displacement, position

Rotary Measurement Technology Absolute Encoders, Multiturn

More Precision. wiresensor // Draw-wire displacement sensors

The Model 464-BC Monitor controls and stores flow data from Marsh- McBirney Flo-Dar sensors. A portable computer and Flo-Ware software is used to

H704-42(H)(E), H704-42/1(H)(E)

FLEX Ex Spring Clamp Terminal Base

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Operation The MICROSONIC sensors are continuous-wave devices that consist of an ultra-high-frequency

Hard Drive user manual

KTM Core CONTRAST SENSORS

User Operation Manual: Motorized Valve Controller for Valved Sources

OPERATION MANUAL. auto range + type K Temp. optional Humidity, Light, Anemometer SOUND LEVEL METER Model : SL-4112

FE Series Photoelectric Sensors

Data Sheet. Model ER position sensor, features a versatile rod-and-cylinder design with optional dual rod ends. Interrogation Return wire.

Flex Series User Guide

DXp-10 and DXp-15 Weight Transmitter

Rotary Measuring Technology Absolute encoders, Singleturn, Profibus-DP

Rotary Measuring Technology Absolute encoders, Multiturn, Profibus-DP

SL7CB100 Stacklight Led Flashing, Yellow, 120V, 70MM

ENERCEPT H8035/H8036 DANGER NOTICE CAUTION. Networked Power Transducer (Modbus RTU) INSTALLATION GUIDE QUICK INSTALL TABLE OF CONTENTS

Minimum cross sectional area of Conductor mm²

Standard CANopen/CANopenLift. RoHS. High protection level. High shaft load capacity. Flexible

ACS HEAVY DUTY INCLINOMETER SAE J1939 INTERFACE

More Precision. wiresensor // Draw-wire displacement sensors

Material: Weight: Shaft Loads: Cable: Connector:

Temperature Switches

07. har-link INTERFACE CONNECTORS

55RQ2 3U, cpci DC/DC Converter 300 Watts Quad Outputs

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

TURCK Modular Industrial I/O PROFIBUS -DP Products

VB Model. Instruction Manual. Vibration Meter. reedinstruments. www. com

TS series Proportional Hall effect thumbsticks

Transcription:

PT9232 Heavy Industrial RS232 Communication Linear Position/Velocity to 550 inches (1400 cm) luminum or Stainless Steel Enclosure Options VLS Option To Prevent FreeRelease amage IP68 NEM 6 Protection Hazardous rea Certification GENERL Full Stroke Ranges 075 to 0550 inches Electrical Interface RS232 Format HEX ccuracy ± 0.10% full stroke Repeatability ± 0.02% full stroke Resolution ± 0.003% full stroke Measuring Cable stainless steel or thermoplastic Enclosure Material powderpainted or 303 stainless steel Sensor plastichybrid precision potentiometer Potentiometer Cycle Life 250,000 cycles Maximum Retraction cceleration see ordering information Maximum Velocity see ordering information Weight, luminum (Stainless Steel) Enclosure 8 lbs. (16 lbs.), max. 7.9 [200 mm] 5.3 [135 mm] The PT9232 delivers position feedback via RS232 serial communication to your data acquisition or controller system. The PT9232 sends a raw 16bit count from 0000H to FFFFH. dditionally this device can be set to continuously send data or send data only when polled. 5.2 [131 mm] Input Voltage Input Current aud Rate ELECTRICL 9...22 VC 40 m 9600 (selectable to 38.4K) s the internal position sensing element is a precision potentiometer, this transducer maintains current accurate position even during power loss and does not need to be reset to a home position. Update Rate 32 msec ENVIRONMENTL Enclosure NEM 4/4X/6, IP 67/68 Operating Temperature 40 to 200 F (40 to 90 C) Vibration up to 10 g to 2000 Hz maximum Output Signal: data stream { 0000x0...... FFFFx0 } (0% fs.) (100% fs.) 20630 Plummer Street Chatsworth, C 91311 PT9232 1

I/O Format ata Format ata Frame Start it ataits Stop it 6 byte Hex string: 1 bit 8 bits 1 bit STX CM 0 1 2 ETX no parity bit STX = 0x02 CM = Command Code* 0 2 = ata Field* ETX = 0x03 * see below Important! ll communications to/from the transducer are in HEX! User Commands: User Command Sensor Response escription <CM> < 0 > < 1 > < 2 > Get Sensor Info 0x05 0x00 0x00 0x00 Get Serial Number 0x15 0x00 0x00 0x00 Start Continuous ata 0x25 0x00 0x00 0x00 Stop Continuous ata 0x35 0x00 0x00 0x00 Get Position ata 0x45 0x00 0x00 0x00 <CM> < 0 > < 1 > < 2 > 0x05 version (4) date (5) date (5) 0x15 serial number (3) 0x25 0x00 0x00 0x00 0x35 0x00 0x00 0x00 0x45 CMC (1) CMC (1) status (2) (1) CMC Current Measurement Count (Position) The Current Measurement Count (CMC) is the output data that indicates the present position of the measuring cable. The CMC is a 16bit value that occupies the first two bytes ( 0 and 1 ) of the data field. 0 is the MS (most significant byte) and 1 is the LS (least significant byte). The CMC starts at 0000H with the measuring cable fully retracted and continues upward to the end of the stroke range stopping at FFFFH. This holds true for all ranges. (2) Status The status byte is used as a flag to indicate the validity of the position signal that the internal electronics receives from the potentiometer. Flags are as follows: 0x00 = GREEN, 0x55 = YELLOW, 0x = RE green flag shows everything OK. yellow or red flag indicates that the sensor has either been extended beyond its range or that there is a problem with the potentiometer. (5) ate (3) Serial Number Each sensor has it s own unique serial number. This information can be retrieved by sending the sensor the Get Serial Number command. The serial number is a 3 byte value from which ranges from 0 to 9999999 (decimal). (4) Version This is a single byte value (0255 decimal) which indicates the currently installed firmware version of the sensor. This is a 2 byte value showing the date of currently installed firmware. This value ranges from 01011 12319 (decimal). Format is MMY. While the month and day are expressed as two digit numbers the year is expressed in a single digit only. Example: 08054 = ugust 5, 2004 aud Rate The baud rate can be set using switches 7 & 8 on the 8pole IP switch found on the rs232 controller board located inside the transducer. RS232 Controller oard and IP Switch Location baud rate switches IP7 IP8 baud rate 0 0 9600 1 0 19200 0 1 38400 1 1 9600 1 2 3 4 5 6 7 8 = "0" = "1" 1 2 3 4 5 6 7 8 1 2 Caution! o Not Remove SpringSide End Cover removing springside end cover could cause spring to become unseated and permanently damaged. internal dip switches & controller board to gain access to the controller board, remove four llenhead Screws and remove end cover bracket. 2 PT9232

Fig. 1 Outline rawing (18 oz. cable tension only) 0.85 [21.6] 6.15 ±0.06 [152,2 ±1,5] mounting hole detail 0.64 [16,3] 0.27 [6,9] eyelet detail Ø.191 [4,19]* Ø.375 [9,52]**.165 [4,19]** 4.80 [121,9] IMENSION (INCHES) 1.10 ±0.08 [27,9 ±2,0] full extension full retraction 4.52 ±0.08 [114,8 ±2,0] MESURING CLE RNGE Ø.034 in. Ø.047 in. Ø.062 in. 75 0.22 0.29 0.37 100 0.29 0.39 0.49 150 0.44 0.59 0.73 200 0.58 0.79 0.98 250 0.73 0.98 1.22 300 0.88 1.18 1.47 350 1.02 1.38 1.71 400 1.17 1.57 1.96 450 1.31 1.77 n/a 500 1.46 1.97 n/a 550 1.61 n/a n/a 4.90 [124,5] 0.25 [6,4] 5.16 [131,1] max. 4.75 ±0.06 [120,7 ±2,0] 7.87 [199,9] max. 5.30 [134,6] IMENSIONS RE IN INCHES [MM] tolerances are 0.03 IN. [0.5 MM] unless otherwise noted. * tolerance = +.005.001 [+.13.03] ** tolerance = +.005.005 [+.13.13] Ordering Information: Model Number: Sample Model Number: PT9232 200 L N34 26 FR M6 PT9232 order code: R C E R C E range: enclosure measuring cable: measuring cable tension: cable exit: electrical connection: 200 inches.034 nyloncoated stainless 18 oz. front (horizontal) 6pin plastic connector Full Stroke Range: R order code: 75 100 150 200 250 300 350 400 450* 500* 550* full stroke range, min: 75 in. 100 in. 150 in. 200 in. 250 in. 300 in. 350 in. 400 in. 450 in. 500 in. 550 in. * 36 oz. cable tension strongly recommended PT9232 3

Ordering Information (cont.): Enclosure Material: order code: L SS powderpainted 303 stainless Measuring Cable: order code: N34 S47 V62 Ø.034inch nyloncoated stainless steel Ø.047inch stainless steel Ø.062inch thermoplastic available in all ranges all ranges up to 500 inches all ranges up to 400 inches Measuring Cable Tension: C order code: tension (30%): enclosure material: max. acceleration: max. velocity: 26 52 18 oz. 36 oz. stainless steel 1 G.33 G 60 inches/sec 20 inches/sec stainless steel 5 G 2 G 200 inches/sec 80 inches/sec standard housing see fig 1. dualspring housing see fig 2. Cable Exit: order code: FR UP K N front top back down Electrical Connection: E order code: M6 C25 6pin plastic connector with mating plug 25ft. instrumentation cable 24 WG, shielded IP 67, NEM 6, NEM 4X (stainless enclosure only) IP 67, NEM 6 3.0 in. [78 mm].30.39 in. [8 10 mm] cable dia. 16 WG max conductor size connector: MS3102E14S6P mating plug: MS3106E14S6S 25 ft. x 0.2in. dia. [7,5 M x 5 mm dia.] 24 WG, shielded F C E contact view pin signal 9...22 VC C Transmitted ata E Received ata F color code signal Red 9...22 VC lack White Green Transmitted ata lue Received ata rown 4 PT9232

Fig. 2 Outline rawing (36 oz. cable tension only) 5.18 ±0.06 [131,6 ±1,5] 0.85 [21,6] mounting hole detail 0.64 [16,3] eyelet detail Ø.191 [4,19]* Ø.375 [9,52]** 4.80 [121,9] 4.90 [124,5] 1.10 ±0.08 [27,9 ±2,0] full extension 0.25 [6,4] full retraction 4.52 ±0.08 [114,8 ±2,0] 5.16 [131,1] max. 0.27 [6,9].165 [4,19]** MESURING CLE RNGE Ø.034 in. Ø.047 in. Ø.062 in. 75 0.22 0.29 0.37 100 0.29 0.39 0.49 150 0.44 0.59 0.73 200 0.58 0.79 0.98 250 0.73 0.98 1.22 300 0.88 1.18 1.47 350 1.02 1.38 1.71 400 1.17 1.57 1.96 450 1.31 1.77 n/a 500 1.46 1.97 n/a 550 1.61 n/a n/a 4.75 ±0.06 [120,7 ±1,5] IMENSION (INCHES) 9.45 [240] max. IMENSIONS RE IN INCHES [MM] tolerances are 0.03 IN. [0.5 MM] unless otherwise noted. 5.30 [134,6] * tolerance = +.005.001 [+.13.03] ** tolerance = +.005.005 [+.13.13] VLS Option Free Release Protection The patented Celesco Velocity Limiting System (VLS) is an option for PT9000 Series cable extension transducers that limits cable retraction to a safe 40 to 55 inches per second for the single spring option and 40 to 80 inches per second for the higher tension dual spring option. The VLS option prevents the measuring cable from ever reaching a damaging velocity during an accidental free release. This option is ideal for mobile applications that require frequent cable disconnection and reconnection. It prevents expensive unscheduled downtime due to accidental cable mishandling or attachment failure. How To Configure Model Number for VLS Option: VLS9232 R C E F G creating VLS model number (example)... 1. select PT9232 model 2. remove PT from the model number 3. add VLS 4. completed model number! PT923201001111110 PT 923201001111110 VLS + 923201001111110 VLS923201001111110 version: 8.0 last updated: March 8, 2013 PT9232 5