midi LOGGER 220 GL220-UM-251

Similar documents
midi LOGGER 200 SERVICE MANUAL GL200-UM-251 GL200-UM

midi LOGGER 820 GL820-UM-251

midi LOGGER 900 SERVICE MANUAL GL900-UM-251 GL900-UM

midi LOGGER GL240 Quick Start Guide GL240-UM-852

midi LOGGER GL240 Quick Start Guide GL240-UM-850

Handy type 10-channel logger midi LOGGER GL200A Sales Manual GRAPHTEC

midi LOGGER GL840 Quick Start Guide GL840-UM-850

After unpacking, check the GL820's Exterior to make sure that there are crack or other damage before use.

midi LOGGER HV GL2000 Quick Start Guide GL2000-UM-851

Druck DPI 620 advanced modular calibrator

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.

SP-100. Service Manual Aug. 02

MOSS-DVR-810 Mobile Digital SD Recorder User Manual

RS Stock No Instruction Manual RS Input Data Logging Thermometer

PLCMTR Commercial Grade Camera System

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour.

User s Guide. OM-EL-WiFi-TH. Shop online at omega.com. OM-EL-WiFi-T-PLUS. Data Logging Sensor

3700 SERIES USER MANUAL

midi LOGGER GL840 Product Introduction (vol. 1, rev. 2) Overseas Sales and Marketing Division

GL200 USER S MANUAL MANUAL NO. GL200-UM-151

GL450 USER S MANUAL MANUAL NO. GL450-UM-151

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

GL980 USER S MANUAL MANUAL NO.GL980-UM-151

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

GL820 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

GL900 USER S MANUAL MANUAL NO. GL900-UM-151

Connecting a Cisco Output Module

GL2000 USER S MANUAL

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

ProScale LCD Readout Quick Start Guide

PLC-24V10AL(-PT/-TH) Quick Start Manual (Rev.1.10)

RS Stock No Instruction Manual RS Input Data Logging Thermometer

DPM Digital DC Power Meter with Data logging capability. User Manual

STYLITIS-POWER OPERATOR S GUIDE

User Guide. TP3016M Series Switching Mode DC Power Supply

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

LED LIGHT METER OPERATION MANUAL. Model : LX-1148SD. SD card real time Data Recorder 10 Light Source select, Auto range 0 to 50,000 LUX

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor.

GL220 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

DP2500 DP0250. Differential Pressure Transmitter. Product Bulletin

Trouble Shooting Leveling Control Box Electric Jacks. Touch Pad LED Probable Cause Solution

Manual Digital Thermometer PCE-T 390

OPERATING INSTRUCTION

EPS 06 in rear housing type A1

F3102 / F3107 / F3110 / F3115 / F3210 / F3215 PN: 86085K K

DPM Bi-directional Digital DC Power Meter with built-in USB data logger & adapter External shunt model. User Manual

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

Programmable Switching DC Power Supply

Plasma Panel Replacement Guide DU-42PX12X

XL112, XL114 ポータブルデータロガ

GL400/350 USER S MANUAL

Single Kernel Grain Moisture Tester PQ-520. (type PQ ) Operating Instructions

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

SI3300. user and installation manual. 4-20mA/DC-Digital Display

User s Guide. OM-EL-WiFi-TH. Shop online at omega.com. OM-EL-WiFi-TP-PLUS. Probe Data Logging Sensor

ALPHA Automated Transfer Switch Operating Manual. Rev 1.21 The original of this document is drawn up in English language

GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2

W Warning To avoid electrical shock, remove test leads and any input signals from the Model 707 Loop Calibrator before opening the case.

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A

GSM HOME SECURITY SYSTEM

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

+GF+ SIGNET ph/orp Transmitter Instructions

BCM2 Series Branch Circuit Monitors Quick Setup Guide

Zone Pressure Touch Sensor - Standard Range

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Eltek TU GenII AQ110A comprehensive portable air quality monitor transmitter

TOSHIBA Potable Printer B-EP4DL SERIES. Maintenance Manual. Document No. EO Original Sep., 2008 (Revised ) PRINTED IN JAPAN

USB-500/600 Series Low-Cost Data Loggers and Accessories

Cellular Alert PRO PRODUCT MANUAL

Junos WebApp Secure 5.0 Hardware Guide

Sidewinder Pumps Inc. AC C1D2 Timer/Controller

Temperature & Humidity Datalogger

12 channels TEMPERATURE RECORDER Model : BTM-4208SD

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

EnCell Battery Cell Monitor

OPERATION MANUAL. SD card real time datalogger 3 Channels TEMPERATURE DATA RECORDER. Model : MTM-380SD. Your purchase of this 3

Setting New Heights in Data Recording

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

ANSI C Dimming Receptacles

user and installation manual

Hygro-Thermometer / Datalogger

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

After unpacking, confirm that there are no problems (scratches and dirt) on the exterior before use.

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

FIELD REPLACEABLE UNIT DOCUMENTATION. Satellite TM. A20 Series GENERAL INFORMATION. Tools Required for Proper Disassembly and Reassembly:

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

TC100 Precision Thermocouple Calibrator

Series 2200 Multichannel Programmable DC Power Supplies User Manual

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

Zone Pressure Touch (ZPT) Sensor - Standard Range

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE

Delta T Dew Heater for CDK

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Table of Contents. 3.1 Front/Rear Panel and User Interface Front Panel Rear Panel User Interface...

SLK Grid PV-inverter (UL) Installation and Operation Manual

Transcription:

midi LOGGER 220 GL220-UM-251 SERVICE MANUAL GL220-UM-251-03-9370

HISTORY OF REVISIONS No. Date issued Description of revision Page Edition 1 10.03.29 First Printing All 01 2 10.04.16 The size of screws were corrected. 3-3, 3-5 02 3 10.05.28 The parts number for the CD-ROM is added. 6-5 03 4 10.05.28 The parts number for the covering seal is removed. 6-3 03 5 10.05.28 The parts number for the main board was corrected. 6-1,6-4 03 6 10.05.28 The parts number for the AMP board was corrected. 6-1,6-3 03 7 8 GL220-UM-251-9370 i

TO ENSURE SAFETY This Service Manual has been compiled for the purpose of facilitating repair and maintenance of the GL220 midi LOGGER by Graphtec service personnel and other persons who have undergone equivalent technical training. Maintenance or repair by unauthorized service personnel is to be strictly avoided. Because the GL220 contains numerous internal components with a high electric potential, such work by unauthorized service personnel could cause human injury or serious damage to the GL220 midi LOGGER. GL220-UM-251-9370 ii

CONTENTS 1. CONFIGURATION... 1-1 1.1 Model Configuration...1-1 1.2 Accessories and Options...1-1 2. UPGRADING THE FIRMWARE... 2-1 2.1 How to Upgrade the GL220 Flash ROM from the USB memory device...2-1 3. DISASSEMBLY AND REASSEMBLY... 3-1 3.1 Notes on Disassembly and Reassembly...3-1 3.2 Removing the Side Pads...3-1 3.3 Disassembling the Top Cover and the Bottom Case Assembly...3-2 3.4 Replacing the Main Control Board...3-3 3.5 Replacing the Control Panel Board...3-5 3.6 Replacing the LCD... 3-6 3.7 Replacing the AMP Board...3-7 3.8 Replacing the Input Terminal Board...3-9 4. SETUP PROCEDURES... 4-1 4.1 Entering the System Setup Menu...4-1 4.2 AC Line cycle Setting... 4-3 4.3 Performing Setup1 (Voltage Input)... 4-4 4.4 Performing Setup2 (Room Temperature Compensation)... 4-8 5. INSPECTION AND CHECK PROCEDURES... 5-1 5.1 Voltage Precision Measuring...5-1 5.2 Temperature Precision Measuring...5-1 5.3 Preparations for inspections and checks...5-2 5.3.1 AC Line cycle Setting... 5-2 5.3.2 Sampling Speed Setting... 5-3 5.3.3 Loading the Condition Settings Files... 5-4 5.4 Inspection and Check Methods... 5-9 5.4.1 Voltage Accuracy... 5-9 5.4.2 Temperature Accuracy...5-12 6. PARTS LISTS... 6-1 6.1 Recommended Parts List...6-1 6.2 Parts Lists...6-2 6.2.1 Outer Casing... 6-2 6.2.2 Bottom Parts... 6-3 6.2.3 Top Parts... 6-4 6.2.4 Replaceable Parts for the Main Control Board... 6-5 6.2.5 Standard Accessories... 6-5 7. Block Diagram... 7-1 GL220-UM-251-9370 iii

1. CONFIGURATION 1. CONFIGURATION 1.1 Model Configuration GL220 : 10-channel model with color monitor and internal memory 1.2 Accessories and Options Unit name Model name Description Humidity Sensor B-530 Same as GL450/500 Battery Pack B-517 Same as GL450/500 DC Drive Cable B-514 Same as GL450/500 Logic alarm cable B-513 Rod-shaped K-type thermocouple RIC-410 K-type thermocouple for static surfaces RIC-420 L-shaped K-type thermocouple for static surfaces RIC-430 GL220-UM-251-9370 1-1

GL220-UM-251-9370 1-2 1. CONFIGURATION

2. UPGRADING THE FIRMWARE The version of your GL220 s firmware can be upgraded by rewriting the flash ROM on the pertinent circuit boards. You can upgrade the firmware by loading the update program to a USB memory device. 2.1 How to Upgrade the GL220 Flash ROM from the USB memory device Preparations for the upgrade Firmware :MainVerxxxRevxxxAxx.GL220 Main Program file for GL220 (xxx and xx is shown the version number.) (1) Connect the AC adapter for the GL220. (2) Turn on the GL220. (3) Copy the two main program files to a USB memory device from the computer. How to upgrade (1) Insert the USB memory device containing the main upgrade program into the GL220's USB port. (2) Turn on the GL220 to automatically execute the upgrade program. (3) Wait until the display shown below appears or until the beeper sound stops. Note: Don't turn off the GL220 until this process is finished. The following message will appear on the GL220 display in yellow characters when the upgrade is complete. Also the beeper will sound for 5 seconds. Please Turn Off the Power. I have locked up. (4) Turn off the power to the GL220 when the above message is displayed or when the beeper sound stops. (5) Delete the two main program files from the USB memory device. This is to avoid upgrading the firmware by mistake. GL220-UM-251-9370 2-1

3. DISASSEMBLY AND REASSEMBLY 3.1 Notes on Disassembly and Reassembly 3. DISASSEMBLY AND REASSEMBLY During disassembly, disconnect the cables from the specified connectors as necessary. During reassembly, double-check to ensure that the proper cables have been correctly re-connected to the pertinent connectors. Some areas of the control panel unit possess a high electrical potential, so exercise caution to avoid an electrical shock. 3.2 Removing the Side Pads Disassembly (1) Peel off the left and right side pads from the main unit. Main Unit Side Pad Re-assembly (1) Push the left and right side pads against the main unit and then install them on the main unit. GL220-UM-251-9370 3-1

3. DISASSEMBLY AND REASSEMBLY 3.3 Disassembling the Top Cover and the Bottom Case Assembly Disassembly (1) Remove the side pads from the main unit (See Section 3.2). (2) Remove the four M2L8 self-tapping screws from the bottom cover. (3) Disconnect the connector between the main control board and the AMP board and then remove the top cover assembly. M2L8 self-tapping screw Bottom case assembly Top cover assembly Re-assembly (1) Re-assemble the top cover assembly and the bottom case assembly in the reverse order in which they were disassembled. GL220-UM-251-9370 3-2

3. DISASSEMBLY AND REASSEMBLY 3.4 Replacing the Main Control Board Disassembly (1) Remove the side pads from the main unit (See Section 3.2). (2) Disassemble the top cover assembly and the bottom case assembly (See Section 3.3). (3) Remove the three M2L6 self-tapping screws holding the main control board from the top cover assembly. M2L6 self-tapping screw 1 3 Main control board 2 Top cover assembly (4) Disconnect the connector between the main control board and the control panel board. Main control board LCD flexible cable Top cover assembly Connector (5) Disconnect the LCD flexible cable from the main control board and then remove the top cover assembly. GL220-UM-251-9370 3-3

3. DISASSEMBLY AND REASSEMBLY Re-assembly (1) Re-assemble the main board in the reverse order in which it was disassembled. (2) Tighten the screws in the screw-number order. (3) Perform the Setup operations for the GL220 when you replace the main control board. GL220-UM-251-9370 3-4

3. DISASSEMBLY AND REASSEMBLY 3.5 Replacing the Control Panel Board Disassembly (1) Remove the side pads from the main unit (See Section 3.2). (2) Disassemble the top cover assembly and the bottom case assembly (See Section 3.3). (3) Remove the main control board (See Section 3.4). (4) Remove the two M2L6 self-tapping screws holding the LCD bracket, and then remove the LCD bracket from the top cover assembly. (5) Remove the five M2L5 self-tapping screws holding the control panel board from the top cover assembly. (6) Remove the control panel board from the top cover assembly. 3 M2L6 self-tapping screw 5 4 1 LCD bracket 2 M2L5 self-tapping screw Control panel board Top cover assembly Re-assembly (1) Re-assemble the control panel board in the reverse order in which it was disassembled. (2) Tighten the screws in the screw-number order. GL220-UM-251-9370 3-5

3. DISASSEMBLY AND REASSEMBLY 3.6 Replacing the LCD The LCD is supplied by the top cover assembly. This is avoiding to get the dust between the LCD and the top cover panel. Disassembly (1) Remove the side pads from the main unit (See Section 3.2). (2) Disassemble the top cover assembly and the bottom case assembly (See Section 3.3). (3) Remove the main control board (See Section 3.4). (4) Remove the control panel board (See Section 3.5). (5) Remove the Key pad from the top cover assembly. (6) Replace the LCD with the top cover assembly. 3 5 4 1 LCD bracket 2 Control panel board Key pad Top cover assembly Re-assembly (1) Re-assemble the LCD in the reverse order in which it was disassembled. (2) Tighten the screws in the screw-number order. GL220-UM-251-9370 3-6

3. DISASSEMBLY AND REASSEMBLY 3.7 Replacing the AMP Board Disassembly (1) Remove the side pads from the main unit (See Section 3.2). (2) Disassemble the top cover assembly and the bottom case assembly (See Section 3.3). (3) Remove the covering seal from the bottom case assembly. Covering seal Bottom case assembly (4) Remove the five M2L6 self-tapping screws holding the AMP board from the bottom case assembly. (5) Remove the AMP board and the input terminal board from the bottom case assembly. 4 2 3 5 1 Input terminal board AMP board M2L6 self-tapping screw Bottom case assembly GL220-UM-251-9370 3-7

3. DISASSEMBLY AND REASSEMBLY (6) Remove the input terminal board from the AMP board. Input terminal board AMP board Re-assembly (1) Re-assemble the AMP board in the reverse order in which it was disassembled. (2) Tighten the screws in the screw-number order. (3) Perform the Setup operations for the GL220 when you replace the AMP board. GL220-UM-251-9370 3-8

3. DISASSEMBLY AND REASSEMBLY 3.8 Replacing the Input Terminal Board Disassembly (1) Remove the side pads from the main unit (See Section 3.2). (2) Disassemble the top cover assembly and the bottom case assembly (See Section 3.3). (3) Remove the covering seal from the bottom case assembly. Covering seal Bottom case assembly (4) Remove the five M2L6 self-tapping screws holding the AMP board from the bottom case assembly. 5 2 1 4 3 Input terminal board AMP board M2L6 self-tapping screw Bottom case assembly (5) Remove the AMP board and the input terminal board from the bottom case assembly. GL220-UM-251-9370 3-9

3. DISASSEMBLY AND REASSEMBLY (6) Remove the input terminal board from the AMP board. Input terminal board AMP board Re-assembly (1) Re-assemble the input terminal board in the reverse order in which it was disassembled. (2) Tighten the screws in the screw-number order. (3) Perform the Setup operations for the GL220 when you replace the input terminal board. GL220-UM-251-9370 3-10

4. SETUP PROCEDURES 4. SETUP PROCEDURES 4.1 Entering the System Setup Menu (1) Press the [MENU] key until the OTHR menu shown below appears. (2) Press the [LEFT DOUBLE ARROW Direction] key 10 times in order to display the Setup menu shown below. (3) Move the cursor to the Mode position using the [Direction] keys. (4) Press the [ENTER] key to display the menu from which you can execute the various Setup operations. Setup mode Setup1 (Basic) Setup2 (Room temp.) (5) Select the Setup mode using the [Direction] keys, and then press the [ENTER] key. GL220-UM-251-9370 4-1

4. SETUP PROCEDURES (6) Move the cursor to the Execute Setup position as shown below. (7) Press the [ENTER] key to start the selected Setup operation. GL220-UM-251-9370 4-2

4. SETUP PROCEDURES 4.2 AC Line cycle Setting You must set the AC Line cycle setting of the GL220 to the same cycle as that of your AC line before you perform the Setup1 and Setup2 operations. How to set the AC line cycle (1) Press the [MENU] key until the "OTHR" menu shown below appears. (2) Move the cursor to the "AC Line cycle" position using the [Direction] keys. (3) Press the [ENTER] key to display the "AC Line cycle" selection menu shown below. (4) Select the appropriate cycle for your AC line. GL220-UM-251-9370 4-3

4. SETUP PROCEDURES 4.3 Performing Setup1 (Voltage Input) This procedure is required when any part of the AMP board is replaced. Preparation Have a voltage generator on hand that can output voltage up to 50 VDC (four-digit output). Mutually connect the ground terminals of the voltage generator and the GL220. Set the AC Line cycle setting of the GL220 to the same cycle as that of your AC line. Wiring connection Voltage voltage generator.) Voltage generator Connect both ends to GND Switch the connection by output voltage. 20mV 1V V Output 2V 50V V Output Input cable Connect to CH1 AC adapter GL220-UM-251-9370 4-4

4. SETUP PROCEDURES Setup procedure (1) As shown in the figure above, connect the output of the voltage generator to the GL220 s CH1 input terminal. (2) Leave the GL220 turned on for at least 30 minutes. (3) After entering the System Setup mode, open the Setup menu as shown below. Specify the AMP Setup conditions as shown below. Mode :Setup1 (Basic) CH :CH 1 (4) Move the cursor to the Execute Setup position as shown below. GL220-UM-251-9370 4-5

4. SETUP PROCEDURES (5) Press the [ENTER] key to start the Setup1 (Basic) operation. Message (6) The GND : [START] message is displayed at the location shown above. (7) Input 0.000mV to the input terminals of channel 1. (8) Press the [START] key and then wait until the "20 mv : [START]" message appears. Specify the voltage generator's output voltage setting to correspond to one of the displayed voltage ranges in the following table, and then input that voltage to the GL220. Message Input Voltage GND 0.000 mv 20 mv 20.000 mv 50 mv 50.000 mv 100 mv 100.000 mv 200 mv 200.000 mv 500 mv 500.000 mv 1 V 1.000 V 2 V 2.000 V 5 V 5.000 V 10 V 10.000 V 20 V 20.000 V 50 V 50.000 V (9) Repeat step (8) by sequentially setting the Measure parameter to 50 mv, 100 mv, 200 mv, 500 mv, 1 V, 2 V, 5 V, 10 V, 20 V and 50 V, and then inputting the corresponding voltage. GL220-UM-251-9370 4-6

4. SETUP PROCEDURES (10) When you have finished the Setup operation for 50 V, the "EEPROM : [ENTER]" message appears. Press the [ENTER] key to begin writing the new Setup data to the EEPROM. Message (11) After the setup parameters have been registered to the EEPROM, the display closes and returns to normal mode. (12) Turn off the GL220. This completes the voltage amp setup. GL220-UM-251-9370 4-7

4. SETUP PROCEDURES 4.4 Performing Setup2 (Room Temperature Compensation) This procedure is required when any part of the AMP board and the terminal board are replaced. Preparation As shown below, use (T: ø0.32 mm, K: ø0.65 mm) temperature compensation leads to connect the input terminals to the 0 C reference temperature device (Zero controller). Set the AC Line cycle setting of the GL220 to the same cycle as that of your AC line. Wiring connection Input 0 V for the output side or short the + and - terminals (K) output side 0 C reference temperature device (Zero Controller) Connect the GND terminals. (K) input side (T) output side (K) compensation lead (T) input side (T) compensation lead AC adapter Connect (T) compensation lead to the CH1, CH3, CH5, CH7 and CH9 input terminals. Connect (K) compensation lead to the CH2 and CH8 input terminals. CAUTION Connect each compensation copper lead to a single terminal as shown in the above diagram (parallel wiring is not permitted). Setup procedure (1) As shown in the figure above, connect the inputs of the zero controller to the GL220 s input terminals. (2) Leave the GL220 turned on for at least 30 minutes. GL220-UM-251-9370 4-8

4. SETUP PROCEDURES (3) After entering the System Setup mode, open the Setup menu as shown below. Specify the AMP Setup conditions as shown below. Mode :Setup2 (Room temp.) Area :Area1 CH :CH 1 (4) Move the cursor to the Execute Setup position as shown above. GL220-UM-251-9370 4-9

4. SETUP PROCEDURES (5) Press the [ENTER] key to start the Setup2 (Room temp.) operation. Message (6) The rtemp : [START] message is displayed at the location shown above. (7) Press the [START] key and then wait until the "EEPROM : [ENTER]" message appears. (8) Press the [ENTER] key to begin writing the new Setup data to the EEPROM. Message (9) After the setup parameters have been registered to the EEPROM, the display closes and returns to normal mode. GL220-UM-251-9370 4-10

4. SETUP PROCEDURES (10) Re-open the Setup menu as shown below. Specify the AMP Setup conditions as shown below. Mode :Setup2 (Room temp.) Area :Area2 CH :CH 1 (11) Repeat steps (4) to (8) for all the areas up to Area5. Setup flow for the Room temp. Procedure Selected area 1 Area 1 2 Area 2 3 Area 3 4 Area 4 5 Area 5 (12) Turn off the GL220. This completes the Room temp. setup. GL220-UM-251-9370 4-11

5. INSPECTION AND CHECK PROCEDURES 5. INSPECTION AND CHECK PROCEDURES 5.1 Voltage Precision Measuring Input the reference voltage for each range according to the table below, and then check that the level of measurement is within the rating. Voltage precision ratings Range Input voltage Rating (±0.08%) 20 mv +20.000 mv +19.984 mv to +20.016 mv 50 mv +50.000 mv +49.96 mv to +50.04 mv 100 mv +100.00 mv +99.92 mv to +100.08 mv 200 mv +200.00 mv +199.84 mv to +200.16 mv 500 mv +500.00 mv +499.6 mv to +500.4 mv 1 V +1.0000 V +0.9992 V to +1.0008 V 2 V +2.0000 V +1.9984 V to +2.0016 V 5 V +5.0000 V +4.996 V to +5.004 V 10 V +10.0000 V +9.992 V to +10.008 V 20 V +20.0000V +19.984 V to +20.016 V 50 V +50.000 V +49.96 V to +50.04 V Specification for GL220: ±0.1% 5.2 Temperature Precision Measuring Input the reference voltage signal for the 0 C reference temperature device (zero controller) according to the table below, then check that the level of measurement is within the rating. T range Input voltage precision ratings (Type T) Temperature Input voltage Standard 0 C 0.000 mv (Short the input terminal) -0.8 C to +0.8 C Specification for GL220: -1.0 to +1.0 C K range Input voltage precision ratings (Type K) Temperature Input voltage Standard 0 C 0.000 mv (Short the input terminal -1.0 C to +1.0 C Specification for GL220: -1.5 to +1.5 C GL220-UM-251-9370 5-1

5. INSPECTION AND CHECK PROCEDURES 5.3 Preparations for inspections and checks 5.3.1 AC Line cycle Setting You must set the AC Line cycle setting of the GL220 to the same cycle as that of your AC line before you perform the inspections. How to set the AC line cycle (1) Press the [MENU] key until the "OTHR" menu shown below appears. (2) Move the cursor to the "AC Line cycle" position using the [Direction] keys. (3) Press the [ENTER] key to display the "AC Line cycle" selection menu shown below. (4) Select the appropriate cycle for your AC line. GL220-UM-251-9370 5-2

5. INSPECTION AND CHECK PROCEDURES 5.3.2 Sampling Speed Setting You must set the sampling speed setting of the GL220 to more than 1 sec before you perform the inspections. GL220-UM-251-9370 5-3

5. INSPECTION AND CHECK PROCEDURES 5.3.3 Loading the Condition Settings Files There are the two condition files to set the measuring condition for the voltage measuring accuracy and the temperature measuring accuracy. Load the condition setting file before measuring each accuracy. Condition settings file :GL220ConditionVolt.CND Condition settings for the voltage accuracy :GL220ConditionTC.CND Condition settings for the temperature accuracy (1) Copy the condition settings file to a USB memory device from the computer. (2) Connect a USB memory device to the GL220 GL220-UM-251-9370 5-4

5. INSPECTION AND CHECK PROCEDURES How to load the condition settings file to the GL220 from a USB memory device (1) Press the [FILE] key, and then move the cursor to the Save position using the [Down Arrow Direction] key. (2) Move the cursor to the Save position using the [Right Arrow Direction] keys. GL220-UM-251-9370 5-5

5. INSPECTION AND CHECK PROCEDURES (3) Press the [ENTER] key to display the menu below. (4) Move the cursor to the File Name position using the [Direction] keys. (5) Press the [ENTER] key to display the menu shown below. (6) Move the cursor to the USB1 position using the [Direction] keys. GL220-UM-251-9370 5-6

5. INSPECTION AND CHECK PROCEDURES (7) Press the [ENTER] key to display the menu shown below. (8) Specify the condition settings file to execute the various inspection operations. (9) Move the cursor to the OK position using the [Direction] keys. GL220-UM-251-9370 5-7

5. INSPECTION AND CHECK PROCEDURES (10) Press the [ENTER] key to display the menu below. (11) Move the cursor to the OK position using the [Direction] keys. (12) Press the [ENTER] key to load the selected condition file. GL220-UM-251-9370 5-8

5. INSPECTION AND CHECK PROCEDURES 5.4 Inspection and Check Methods 5.4.1 Voltage Accuracy Supply the reference voltage or frequency determined for each measurement range, and then check the voltage accuracy. Preparation Have a voltage generator on hand that can output voltage up to 50 VDC (using four-digit output). Mutually connect the ground terminals of the voltage generator and the GL220 prior to initiating measurement. Set the AC Line cycle setting of the GL220 to the same cycle as that of your AC line. Set the sampling speed setting of the GL220 to more than 1 sec. Wiring connection Same wiring connection as Setup1. (See Setup1 procedure) Setting procedure (1) Load the condition settings file "GL220ConditionVolt.CND" from the USB memory device. Measurement procedure (1) Press the [MENU] key to display the AMP menu shown below. (2) Move the cursor to the Range position of channel 1. GL220-UM-251-9370 5-9

5. INSPECTION AND CHECK PROCEDURES (3) Press the [ENTER] key to display the menu shown below, and then select the reference voltage range. (4) Press the [DISPLAY] key until the menu shown below appears. (5) Press the [Left Double Arrow Direction] key to Display the menu below. GL220-UM-251-9370 5-10

5. INSPECTION AND CHECK PROCEDURES (6) Input the reference voltage for each range according to the table below, and then check that the level of measurement is within the rating. Voltage precision ratings Range Input voltage Rating (±0.08%) 20 mv +20.000 mv +19.984 mv to +20.016 mv 50 mv +50.000 mv +49.96 mv to +50.04 mv 100 mv +100.00 mv +99.92 mv to +100.08 mv 200 mv +200.00 mv +199.84 mv to +200.16 mv 500 mv +500.00 mv +499.6 mv to +500.4 mv 1 V +1.0000 V +0.9992 V to +1.0008 V 2 V +2.0000 V +1.9984 V to +2.0016 V 5 V +5.0000 V +4.996 V to +5.004 V 10 V +10.0000 V +9.992 V to +10.008 V 20 V +20.0000V +19.984 V to +20.016 V 50 V +50.000 V +49.96 V to +50.04 V This value will change when the reference voltage is input from the voltage generator. (7) Press the [START/STOP] key when the input voltage stabilizes. (8) Wait until the "Finished" message is displayed, and then display the values as shown below. Message Confirm that this value is within the above ratings after data has been captured. The data with an automatically generated file name is captured to the memory. (9) Repeat steps (1) to (7), and then confirm that each value is within the above ratings. GL220-UM-251-9370 5-11

5. INSPECTION AND CHECK PROCEDURES 5.4.2 Temperature Accuracy Preparation Use (T: ø0.32 mm, K: ø0.65 mm) temperature compensation leads to connect the input terminals to the 0 C reference temperature device (Zero controller). Set the AC Line cycle setting of the GL220 to the same cycle as that of your AC line. Set the sampling speed setting of the GL220 to more than 1 sec. Wiring connection Same wiring connection as Setup2. (See Setup2 procedure) Setting procedure (1) Load the condition settings file GL220ConditionTC.CND from the USB memory device. Measurement procedure (Temperature accuracy) (1) Input the reference voltage signal for the 0 C reference temperature device (zero controller) according to the table below T range Input voltage precision ratings (Type T) Temperature Input voltage Standard 0 C 0.000 mv (Short the input terminal) -0.8 C to +0.8 C Specification for GL220: -1.0 to +1.0 C K range Input voltage precision ratings (Type K) Temperature Input voltage Standard 0 C 0.000 mv (Short the input terminal -1.0 C to +1.0 C Specification for GL220: -1.5 to +1.5 C (2) Check that the level of measurement is within the rating in the menu below. Confirm that this value is within the above ratings after data has been captured. GL220-UM-251-9370 5-12

6. PARTS LISTS 6. PARTS LISTS 6.1 Recommended Parts List Part No. Part Name Description Q'ty Remarks 795220706 Main Control Board for GL220 1 795220707 AMP Board for GL220 1 795220704 Input Terminal Board for GL220 1 795220705 Control Panel Board for GL220 1 562500022 AC Adapter KSAH2400200T1M2 1 Without AC Cable 795450004 Battery Pack 1 Same as GL450 GL220-UM-251-9370 6-1

6. PARTS LISTS 6.2 Parts Lists 6.2.1 Outer Casing No. Part No. Part Name Description Q'ty Remarks Rank 1 795220702 Top Cover Assy, GL220 1 With LCD A 2 795220703 Bottom Case Assy, GL220 1 C 3 604220050 Side Pad, Left 1 C 4 604220060 Side Pad, Right 1 C Outer Casing 1 3 2 4 GL220-UM-251-9370 6-2

6. PARTS LISTS 6.2.2 Bottom Parts No. Part No. Part Name Description Q'ty Remarks Rank 1 795220707 AMP Board, GL220 1 A 2 795220704 Input Terminal Board, GL220 1 A 3 604220030 Battery Cover, GL220 1 C 4 795220703 Bottom Case Assy, GL220 1 C 5 604900040 Tilt Foot 2 C Bottom Parts 2 1 5 3 4 GL220-UM-251-9370 6-3

6. PARTS LISTS 6.2.3 Top Parts No. Part No. Part Name Description Q'ty Remarks Rank 1 795220706 Main Control Board, GL220 1 With SD card A 2 795220705 Control Panel Board, GL220 1 A 3 604220040 Key Switch 1 B 4 604220090 LCD Bracket 1 A 5 795220702 Top Cover Assy, GL220 1 With LCD A Top Parts 1 2 4 3 5 GL220-UM-251-9370 6-4

6. PARTS LISTS 6.2.4 Replaceable Parts for the Main Control Board No. Part No. Part Name Description Q'ty Remarks Rank 1 561500112 USB Connector, XM7A-0442 1 B 2 561500082 USB Connector, XM7B-0442 1 B 3 562070001 Battery, ML2430-TT2 1 B 6.2.5 Standard Accessories No. Part No. Part Name Description Q'ty Remarks Rank 1 604229070 CD-ROM, GL220-CDM01M CD Manual, Software 1 C 2 604229050 QS Manual, GL220-UM-801 Quick Start Manual 1 Japanese C 3 604229060 QS Manual, GL220-UM-851 Quick Start Manual 1 English C 4 562500022 AC Adapter KSAH2400200T1M2 1 Without AC Cable A 5 562500024 AC Adapter Cable, UL UL AC Cable, 1.5M 1 UL B 6 562500025 AC Adapter Cable, CEE CEE AC Cable, 1.5M 1 CEE B 7 562500026 AC Adapter Cable, BS BS AC Cable, 1.5M 1 BS B 8 562500027 AC Adapter Cable, CCC CCC AC Cable, 1.5M 1 CCC B 9 562500023 AC Adapter Cable, PSE PSE AC Cable, 1.5M 1 Japan B GL220-UM-251-9370 6-5

7. BLOCK DIAGRAM 7. Block Diagram Pulse / Logic / Alarm / Trigger 5V Out Input Terminal Board RN8112-03 GND AC Adapter O AMP Board RN8112-02 Main Control Board RN8112-01 Key Board RN8112-04 Power Switch BATTERY PACK Option PC LCD COM43H4M09XLC 4.3inch WQVGA(272x480) I Flash Emulator GL220-UM-251-9370 7-1