Supplementary Circuit Protectors Type GSB63

Similar documents
1492-SP Supplementary Protectors

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

TeSys IEC Contactors and Overload Relays

9926 Series Branch Rated Circuit Breakers AC Version

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

Introduction Circuit Protection

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Allen-Bradley 1492-RCDA4A40

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Miniature Circuit Breakers and Supplementary Protectors. Contents

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Selection Guide. Control Circuit and Load Protection

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Selection Guide. Control Circuit and Load Protection

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

Jtec 10kA Miniature Circuit Breaker

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

Control Circuit and Load Protection Products

Product Guide. UL 1077 DIN Rail Supplementary Protectors

For Sales and Support call KMParts.com (866)

Product Guide. UL 489 DIN rail miniature circuit breakers

Motor protection relays

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

60103 Circuit Breaker

ic60n RCBO 30 ma IEC , IEC , AS/NZS

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation

Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications.

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

WEG Contactors - CWM and CWME Series

Section 4 Ground-Fault Protection Devices

3 Pole Contactors with AC operating coils

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

Horizontal distribution busbar HX 3 80/125 A plug-in

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Thermal-Magnetic Circuit Breaker 4220-T...

Square D General Purpose Relays

WMS SUPPLEMENTARY PROTECTORS

Introduction Electronic Circuit Protection ESX10-T

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

DSE201, DSE201 M Compact design with enhanced protection

MOTOR & CIRCUIT PROTECTION

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Mini Contactors & Overloads

Overvoltage Protection

Rated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a

MULTI 9 System Catalog

Supplemental Protectors

Electronic timer CT-ARS.11

Thermal-Magnetic Circuit Breaker 2216-S

Ordering Key. Type Rated Operational Rated operational Control Voltage Uc Options

em4 Accessories Digital expansions

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

Electronic timer CT-ERD.12

Circuit and Surge Protection Protection Solutions Catalog. North America

Circuit Breakers Type CTI 25M, CTI 45MB

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

Minimum space, maximum protection DS203NC: 3P+N RCBOs in 4 modules

Application Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400

02/11/2015

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Electronic timer CT-AHD.22

Electronic timer CT-ERS.21

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Motor protection circuit breakers

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

Motor protection circuit breakers

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

QF(26) - Series Miniature Circuit Breakers - High Rating ( A)

CS8 Industrial Control Relays

Datasheet - SRB 301LC/B-24V

Micro Contactor MA Series

ict contactors EN 61095, IEC 1095 Interference

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

TeSys protection components

RM35LM33MW liquid level control relay RM35-L V AC/DC

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Datasheet - SRB 402EM-24V

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Transcription:

Supplementary Circuit Protectors Type GSB63 l Protection of circuits against short circuit and overload currents l UL1077 supplementary protection l 1,, 3 and 4 pole arrangements l 13 amperage sizes up to 63Amps l Icn of 5kA l Bimetallic element for small overloads l Magnetic element for short circuit protection l B, C, D trip characteristics l Full line of bus bars and connectors l Auxiliary contact, alarm switch and shunt release accessories Product Description Ordering Key GSB63 1P C 0 Competitive line of supple- or not required. GSB pro-mentary circuit protectors tectors are available in 1, intended for over current, 3 and 4 pole configura-protection in applications tions, with amperage rating where branch circuit proup to 63A and voltage up to tection is already provided 480Y/77VAC. Supplementary Protector Number of poles Tripping Characteristics Overload range Selection Guide (Refer to page for list of valid part numbers) SCP Numbers of poles Tripping Characteristics Overload Range (amps) GSB63 Family 1P C C curve 1,, 3, 4, 6, 10, P (standard) 16, 0, 5, 3, 40, 3P B B curve 50, 63 4P D D curve Specifications are subject to change without notice September-016 1

Electrical GSB63 Selection Guide C Curve In 1 3 4 6 10 16 0 5 3 40 50 63 1-pole GSB63 1P C1 GSB63 1P C GSB63 1P C3 GSB63 1P C4 GSB63 1P C6 GSB63 1P C10 GSB63 1P C16 GSB63 1P C0 GSB63 1P C5 GSB63 1P C3 GSB63 1P C40 GSB63 1P C50 GSB63 1P C63 -pole GSB63 P C1 GSB63 P C GSB63 P C3 GSB63 P C4 GSB63 P C6 GSB63 P C10 GSB63 P C16 GSB63 P C0 GSB63 P C5 GSB63 P C3 GSB63 P C40 GSB63 P C50 GSB63 P C63 3-pole GSB63 3P C1 GSB63 3P C GSB63 3P C3 GSB63 3P C4 GSB63 3P C6 GSB63 3P C10 GSB63 3P C16 GSB63 3P C0 GSB63 3P C5 GSB63 3P C3 GSB63 3P C40 GSB63 3P C50 GSB63 3P C63 4-pole GSB63 4P C1 GSB63 4P C GSB63 4P C3 GSB63 4P C4 GSB63 4P C6 GSB63 4P C10 GSB63 4P C16 GSB63 4P C0 GSB63 4P C5 GSB63 4P C3 GSB63 4P C40 GSB63 4P C50 GSB63 4P C63 B Curve In 1 3 4 6 10 16 0 5 3 40 50 63 1-pole GSB631PB1 GSB631PB GSB631PB3 GSB631PB4 GSB631PB6 GSB631PB10 GSB631PB16 GSB631PB0 GSB631PB5 GSB631PB3 GSB631PB40 GSB631PB50 GSB631PB63 -pole GSB63PB1 GSB63PB GSB63PB3 GSB63PB4 GSB63PB6 GSB63PB10 GSB63PB16 GSB63PB0 GSB63PB5 GSB63PB3 GSB63PB40 GSB63PB50 GSB63PB63 3-pole GSB633PB1 GSB633PB GSB633PB3 GSB633PB4 GSB633PB6 GSB633PB10 GSB633PB16 GSB633PB0 GSB633PB5 GSB633PB3 GSB633PB40 GSB633PB50 GSB633PB63 4-pole GSB634PB1 GSB634PB GSB634PB3 GSB634PB4 GSB634PB6 GSB634PB10 GSB634PB16 GSB634PB0 GSB634PB5 GSB634PB3 GSB634PB40 GSB634PB50 GSB634PB63 D Curve In 1-pole -pole 3-pole 4-pole 1 GSB631PD1 GSB63PD1 GSB633PD1 GSB634PD1 GSB631PD GSB63PD GSB633PD GSB634PD 3 GSB631PD3 GSB63PD3 GSB633PD3 GSB634PD3 4 GSB631PD4 GSB63PD4 GSB633PD4 GSB634PD4 6 GSB631PD6 GSB63PD6 GSB633PD6 GSB634PD6 10 GSB631PD10 GSB63PD10 GSB633PD10 GSB634PD10 16 GSB631PD16 GSB63PD16 GSB633PD16 GSB634PD16 0 GSB631PD0 GSB63PD0 GSB633PD0 GSB634PD0 5 GSB631PD5 GSB63PD5 GSB633PD5 GSB634PD5 3 GSB631PD3 GSB63PD3 GSB633PD3 GSB634PD3 40 GSB631PD40 GSB63PD40 GSB633PD40 GSB634PD40 50 GSB631PD50 GSB63PD50 GSB633PD50 GSB634PD50 63 GSB631PD63 GSB63PD63 GSB633PD63 GSB634PD63 Part numbers in bold font indicate stock item Specifications are subject to change without notice September-016

Electrical GSB63 Electrical Specifications Mechanical Specifications Rated Current Poles Rated Voltage Insulation Voltgae Rated Frequency Rated Breaking capacity Rated Impulse Withstand Voltage (1./50) Dielectric Test Voltage for 1 minute Pollution Degree Power loss per pole 1,, 3, 4, 5, 6, 10 A 13, 16, 0, 5, 3 A 40, 50, 63 A Thermo magnetic release characteristics Electrical life 1,, 3, 4, 6, 10, 16, 0, 5, 3, 40, 50, 63 A 1,, 3 or 4 pole single phase 77 VAC three phase 480Y/77VAC 500 VAC 50/60 Hz 5,000 A 4,000 V,000 V W 3.5 W 5 W B, C (standard), D 4,000 cycles Mechanical life 0,000 cycles Contact Position Indicator Yes Protection Degree IP0 Reference Temperature 30 C Operation Temperature -35 C ~ +70 C (see table on Range page 3 for derating) Terminal Connection Type Copper/U-type busbar/pintype busbar Wire Size Range 18-4 AWG Busbar size range 18-8 AWG Maximum tightening torque In-lbs. (N*m ) Mounting Vertical on DIN rail EN 60715 (35mm) Connection Line-in on top, line-out on bottom Specifications are subject to change without notice September-016 3

Technical GSB63 Specifications Temperature Derating The maximum permissible current in a supplementary protector depends on the ambient temperature and spacing between devices (see next paragraph). Ambient temperature is the temperature inside the enclosure or switch-board in which circuit breaker is installed. The reference temperature for nominal current rating is 30 C. Ambient Temp > -35 C -30 C -0 C -10 C 0 C 10 C 0 C 30 C 40 C 50 C 60 C 70 C Rated Current 1A 1.30 1.6 1.3 1.19 1.15 1.11 1.05 1.00 0.96 0.93 0.88 0.83 A.60.5.46.38.8.0.08.00 1.9 1.86 1.76 1.66 3A 3.90 3.78 3.69 3.57 3.4 3.30 3.1 3.00.88.79.64.49 4A 5.0 5.04 4.9 4.76 4.56 4.40 4.16 4.00 3.84 3.76 3.5 3.3 6A 7.80 7.56 7.38 7.14 6.84 6.60 6.4 6.00 5.76 5.64 5.8 4.98 10A 13.0 1.76 1.50 1.00 11.50 11.10 10.60 10.00 9.60 9.30 8.90 8.40 16A 1.1 0.48 0.00 19.0 18.40 17.76 16.96 16.00 15.36 14.88 14.4 13.44 0A 6.40 5.60 5.00 4.00 3.00.0 1.0 0.00 19.0 18.60 17.80 16.80 5A 33.00 3.00 31.5 30.00 8.75 7.75 6.50 5.00 4.00 3.5.5 1.00 3A 4.56 1.8 40.00 38.7 37.1 35.5 33.9 3.00 30.7 9.76 8.16 6.88 40A 53.0 51.0 50.00 48.00 46.40 44.80 4.40 40.00 38.40 37.0 35.60 33.60 50A 67.00 65.50 63.00 60.50 58.00 56.00 53.00 50.00 48.00 46.50 44.00 41.50 63A 83.79 81.90 80.01 76.86 73.71 70.56 66.78 63.00 60.48 58.90 55.44 5.9 Curve Profiles Specifications are subject to change without notice September-016 4

Technical GSB63 Specifications Accessories Auxiliary Contact General Ordering key: GSBXF9 Indication of the position of the device s contacts. To be mounted on the left side of the UL1077 supplementary protector, thanks to the special pin. Technical data Standard IEC/EN 60947-5-1 Voltage Current AC415 50/60HZ 3A Rated value AC40 50/60HZ 6A DC130 1A DC48 A Electrical features DC4 6A Configurations 1 N/O + 1 N/C Rated impulse withstand voltage (1./50)Uimp V 4000 Dielectric TEST voltage at ind. Freq. for 1min kv Insulation voltage Ui V 500 Pollution degree Electrical life 6,050 Mechanical life 10,000 Mechanical features Protection degree IP0 Ambient temperature (with daily average 35 C) C -5...+40 Storage temperature C -5...+70 Installation Terminal connection type Cable Terminal size top/bottom for cable mm².5 AWG 18 ~ 14 Tightening torque N m 0.8 In-Ibs. 7 Approvals: CE only Specifications are subject to change without notice September-016 5

GSB63 Alarm Switch General Ordering key: GSBXF9J Indication of the position of the device s contacts only after the automatic release of the UL1077 supplementary protector, due to an overload or a short-circuit. To be mounted on the left side of the UL1077 device thanks to the special pin. Technical data Standrad IEC/EN 60947-5-1 Voltage Current AC415 50/60HZ 3A Rated value AC40 50/60HZ 6A DC130 1A DC48 A Electrical features DC4 6A Configurations 1 N/O + 1 N/C Rated impulse withstand voltage (1./50)Uimp V 4000 Dielectric TEST voltage at ind. Freq. for 1min kv Insulation voltage Ui V 500 Pollution degree Electrical life 6,050 Mechanical life 10,000 Mechanical features Protection degree IP0 Ambient temperature (with daily average 35 C) C -5...+40 Storage temperature C -5...+70 Installation Terminal connection type Cable Terminal size top/bottom for cable mm².5 AWG 18 ~ 14 Tightening torque N m 0.8 In-Ibs. 7 Approvals: CE only Specifications are subject to change without notice September-016 6

GSB63 Shunt realease General Ordering key: GSBS9 Remote opening of the device when a voltage is applied. To be mounted on the left side of the UL1077 supplementary protector, thanks to the special pin. Technical data Standard IEC/EN 60947-5-1 Rated value Voltage 4VDC Electrical features Configurations 1 N/O + 1 N/C Rated impulse withstand voltage (1./50)Uimp V 4000 Dielectric TEST voltage at ind. Freq. for 1min kv Insulation voltage Ui V 500 Pollution degree Mechanical features Electrical life 4,000 Mechanical life 4,000 Protection degree IP0 Ambient temperature (with daily average 35 C) C -5...+70 Storage temperature C -5...+70 Installation Terminal connection type Cable Terminal size top/bottom for cable mm².5 Approvals: Tightening torque AWG 18 ~ 14 N m 0.8 In-Ibs. 7 CE only Specifications are subject to change without notice September-016 7

GSB63 Busbars and Connectors Accessory Busbar Feeder Center feeder End cap Poles Pins Part Number Description 1 3 6 GSBB1P06H 1 GSBB1P1H 18 GSBB1P18H 57 GSBB1P57H 37 GSBB1P37HS 6 GSBBP06H 1 GSBBP1H 18 GSBBP18H 56 GSBBP56H 46 GSBBP46HS 6 GSBB3P06H 1 GSBB3P1H 18 GSBB3P18H 57 GSBB3P57H 48 GSBB3P48HS 1 GSBBFEED1P, 3 GSBBFEED3P all GSBBCENFEED 1 GSBBENDCAP1P, 3 GSBBENDCAP3P 6 pins busbar 1 1 pins busbar 1 18 pins busbar 1 cuttable 57 pins busbar 1 cuttable 37 pins busbar 1 pole GSB+AUX 6 pins busbar 1 pins busbar 18 pins busbar cuttable 57 pins busbar cuttable 37 pins busbar pole GSB+AUX 6 pins busbar 3 1 pins busbar 3 18 pins busbar 3 cuttable 57 pins busbar 3 cuttable 37 pins busbar 3 pole GSB+AUX Feeder terminal 1 Feeder terminal & 3 Center feeder terminal End cover 1 pole GSB End cover & 3 Pin cap all GSBBPINCAP Protective pin cap Combined Amperage Rating 100A Rated voltage 600 VAC / 1000 VDC Dimmentions [mm / in] A B C D 89 / 3.5 17.8 / 0.70 5.5 / 0. 16.7 / 0.66 100A 196 / 7.7 17.8 / 0.70 5.5 / 0. 16.7 / 0.66 100A 303 / 11.9 17.8 / 0.70 5.5 / 0. 16.7 / 0.66 100A 997 / 39.5 17.8 / 0.70 5.5 / 0. 15.6 / 0.61 100A 97 / 38.7 17.8 / 0.70 5.5 / 0. 15.6 / 0.61 100A 600 VAC / 600 VDC 89 / 3.5 17.8 / 0.70 5.5 / 0. 36.5 / 1.44 100A 196 / 7.7 17.8 / 0.70 5.5 / 0. 36.5 / 1.44 100A 303 / 11.93 17.8 / 0.70 5.5 / 0. 36.5 / 1.44 100A 979 / 38.54 17.8 / 0.70 5.5 / 0. 36.5 / 1.44 100A 968 / 38.11 17.8 / 0.70 5.5 / 0. 36.5 / 1.44 100A 89 / 3.5 17.8 / 0.70 5.5 / 0. 36.5 / 1.44 100A 196 / 7.7 17.8 / 0.70 5.5 / 0. 36.5 / 1.44 100A 303 / 11.93 17.8 / 0.70 5.5 / 0. 36.5 / 1.44 100A 997 / 39.5 17.8 / 0.70 5.5 / 0. 36.5 / 1.44 100A 935 / 36.81 17.8 / 0.70 5.5 / 0. 36.5 / 1.44 115A 115A 115A n / a 600 VAC / 600 VDC n / a Part number in bold font indicate stock items Approvals - CE, culus (UL508) Specifications are subject to change without notice September-016 8

Technical GSB63 Specifications Dimensions 45 ± 0.31 34.5 ± 0.5 86 0-1.4 49.5 ± 0.31 18 0-0.43 36 0-0.6 54 0-1. 7 0-1. 78 0-1. 1P 1P+N, P 3P 3P+N, 4P Agency Approvals GSB Supplementary Protectors E365997 GSB Supplementary Protectors GSBB Busbars and Busbar Accessories E483985 Specifications are subject to change without notice September-016 9