Horizontal distribution busbar HX 3 80/125 A plug-in

Similar documents
DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

EMS CX 3 - State and control module for Latching relays and Contactors

EMS CX 3 - Pulse concentrator module

EMS BTDIN - State and control module for Latching relays and Contactors

EMS CX 3 - Signalling Auxiliary Contact (CA + SD)

EMS BTDIN- Power supply & Connection Equipments

Mini Energy Web Server

EMS CX 3 - State and control module for Latching relays and Contactors

EMS BTDIN - Pulse concentrator module

EMS CX 3 - Modbus/EMS Interface

EMS BTDIN - Signalling Auxiliary Contact (CA + SD)

Nemo SX - Multifunction control module

Pulse concentrator, 12 inputs, 4 mod. DIN, with RS485 port

XL 4000 metal free-standing enclosures and cable compartments

DSE201, DSE201 M Compact design with enhanced protection

ic60n RCBO 30 ma IEC , IEC , AS/NZS

Modular surge protective devices (SPDs)

Modular surge protective devices (SPDs)

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

Supplementary Circuit Protectors Type GSB63

- 1 - Product catalogue PCB connection systems PCB terminals Clamping yoke connection LM 5.00 / 5.08 LM 5.00/135

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

1492-SP Supplementary Protectors

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

02/11/2015

Electronic timer CT-ARS.11

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches

Pan assemblies and installation accessories

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Electronic timer CT-ERS.21

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Allen-Bradley 1492-RCDA4A40

XB7NG33 key selector switch - Ø 22 - keylock - 3 positions - 2 NO - Ronis 455 center

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

Disconnect Switches. Safe Switching and Disconnecting

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Datasheet - SRB 402EM-24V

Modular surge protective devices (SPDs) Cat. Nos :

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

XB7EV07BP round pilot light Ø 22 - clear - integral LED - 24 V - screw clamp terminals

Multifuncion Measuring Device 96x96 mm, connection via CT

Thermal-Magnetic Circuit Breaker 2216-S

XB7NA4234 PB - Spring Rtn, red - 1NC -White "STOP"

ict contactors EN 61095, IEC 1095 Interference

Electronic timer CT-ERD.12

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

Redundancy unit CP-A RU

XB4BK123B5. Product data sheet Characteristics. Complete illuminated selector switch. position stay put 1NO+1NC 24V. Main.

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

XB7NS8442 Emergency stop Ø 22 - red - mushroom head Ø 40 mm - turn to release - 1 NC

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Electronic timer CT-AHD.22

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

Add-on Residual Current Protection PBSM MW

RM35LM33MW liquid level control relay RM35-L V AC/DC

ZB4BW061 light block with body/fixing collar for BA9s bulb 250V 1NO

OsiSwitch Limit Switches Innovation through modularity

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

Datasheet - SRB 301LC/B-24V

Datasheet SRB301ST 24V (V.2)

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Defender B Board. Make The Switch

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-D2V100W1A. V1: 3.50A (Selectable by Switch) V2: 5Vdc

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Miniature Circuit Breakers for Railway Applications

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

PMT. Safety Standards. Model Number:

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

PMR. PMR Panel Mount Power Supply 4.2V 252W 1 Phase / PMR-4V320WC A. Highlights & Features. Safety Standards. Model Number: General Description

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

Datasheet - AZM 200 BZ ST-T-AS P

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

5SL Miniature Circuit Breakers

Surge Protection Devices Ex9UE2

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

XB5AS8445 red Ø40 Emergency stop, switching off Ø22 trigger latching turn release 1NO+1NC

Transcription:

87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Horizontal distribution busbar HX 3 CONTENTS Pages 1. Description... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection... 3 5. General Characteristics... 8 6. Compliance and approvals... 9 1. DESCRIPTION 1. DESCRIPTION - USE Plug-in horizontal distribution system: used for 3-phase distribution without wiring of modular devices up to 125 A on a single row. Automatic connection and disconnection of equipment totally safely, even when the distribution busbar is powered-up, thanks to the IP XXB insulation and the integral connection modules in the devices. Total freedom to install and combine devices: 1P+N, 2P, 3P, 4P, add-on modules, auxiliaries, control devices, etc. Selection of the phase to be connected by selecting the connection module. For mounting in XL³ 400/800/4000 enclosures with 2-position aluminium rail (Cat.nos 0 202 06, 0 206 01/51) and in XL 3 160 enclosures with the mounting accessory (Cat. no 4 052 24). It can be used in panel h = 150mm. 3. OVERALL DIMENSIONS. Distribution busbar: 2. RANGE Automatic distribution blocks. Fixed directly onto DIN rails Cat nos 0 202 06, 0 206 01/51. Delivered with a supply module and a phase security cover of the distribution busbar Cat. no 4 052 40: 24 modules Cat. no 4 052 41: 36 modules Connection modules:. Used for automatic connection and disconnection of modular devices on the horizontal distribution busbar. Cat. n 4 052 43: set of 10 connection modules L1 Cat. n 4 052 44: set of 10 connection modules L2 Cat. n 4 052 45: set of 10 connection modules L3 Cat. n 4 052 46: set of 10 connection modules N for devices 1 module per pole. Cat. n 4 052 23: set of 3 connection modules L1N, L2N, L3N for devices 1P+N in 1 module screws or automatic terminals. Accessories for mounting in XL 3 160 enclosure Cat. n 4 052 24: used for mounting the 80/125 A horizontal busbar 24 modules (cat. n 4 052 40) in XL 3 160 enclosure. Rated Voltages and Frequency:. 230 V ~ / 400 V~ - 50 / 60 Hz with standard tolerances. Rated Currents:. Max.125 A (with the power supply module).. Max.80 A (without the power supply module). Modules L (mm) 24 432 36 652 1/9

Horizontal distribution busbar HX 3 3. OVERALL DIMENSIONS (continued). Power supply module, cat n 4 052 42: 3. OVERALL DIMENSIONS (continued). Connection module 1P, cat n (s) 4 052 43/44/45/46:. Connection module 1P+N (Cat.. no 4 052 23):. Power supply security module (delivered with power supply module):. Lateral view of the cabled system: 2/9

4. PREPARATION - CONNECTION Fixing: Assembly of the various elements of the system:. On dedicated rail cat. no 4 052 26.. Horizontal distribution busbar: XL3 400, XL3 800, XL3 4000 enclosures List of modular compatible devices: DX³ Modular compatible device: MCBs 1P+N in 1 module, automatic or screws terminals RCBOs 1P+N feeder protection Connection modules 4 052 40/41 4 052 23 (L1N, L2N, L3N) neutral on the left RCDs 1P+N feeder protection RCDs 2P feeder protection 0 202 06, 0 206 01/51 RCDs 4P feeder protection RCBOs 2P feeder protection RCBOs 4P feeder protection MCBs 1P, 2P, 3P, 4P 1module/pole (*) MCBs 2p and 4P associated to RCD add-on modules 4 052 43: L1 4 052 44: L2 4 052 45: L3 4 052 46: N IS (*)Except products dedicated to four pole Prong busbars HX 3 System power supply:. Direct power supply via the power supply module. In this configuration the operating current can be max 125A.. Indirect power supply via head of row device: The distribution busbar is protected by the head of group device. I this configuration the operating current is limited by the rated current of the head device (max. 80A). 3/9

. Horizontal distribution busbar (continued): XL3 160 enclosure. Supply module associated to an MCB: 4 052 24 Supply module - Terminal capacity: Copper cables Without ferrule Without ferrule Rigid cable 6 mm² à 50 mm² - Flexible cable 6 mm² à 35 mm² 6 mm² à 35 mm² Tightening torque:. Recommended: 4Nm.. Min: 3 Nm. Max: 5 Nm. Tools required:. For the terminals: Allen wrench 4 mm. 4/9

. Supply module (cat n 4 052 42) associated to the power supply security module: used to supply directly the busbar.. Connection modules 1P (cat. n n (s) 4 052 43/44/45/46): No tools required to assembly the connection module to the device.. Connection module 1P+N (cat. n 4 052 23): No tools required to assembly the connection module to the MCB 1P+N in 1 module with automatic terminals Supply module - Terminal capacity: Copper cables Without ferrule With ferrule Rigid cable 6 mm² a 50 mm² - Flexible cable 6 mm² a 35 mm² 6 mm² a 35 mm² Tightening torque:. Recommended: 4Nm.. Min: 3 Nm. Max: 5 Nm. Tools required:. For the terminals: Allen wrench 4 mm. 5/9

Assembly of the various elements of the system in case of use of a MCCB:. Connection module 1P+N (cat. n 4 052 23:: neutral on the left): left To assembly the connection module to the device 1P+N in 1 module is necessary a screwdriver Pozidriv n 2. Recommended tightening torque: 1,6 to 2 Nm. 0 202 06, 0 206 01/51 L (mm) DPX3 3P 4P 160 82 108 250 105 140 6/9

Assembly of the various elements of the system in case of use of a MCCB: Supply of a device that can t be equipped with the connection modules:. This operation is possible with the connection modules 1P.. Fix the device to be powered on the DIN rail Cat nos 0 202 06, 0 206 01/51.. Break the pre-fracture fracture on the connection module and connect the supply cables between the switch and the device to be powered. 0 202 06, 0 0 206 01/51 WARNING: In this configuration the maximum current derivable from the devices is 80A. 7/9

5 GENERAL CHARACTERISTICS 5 GENERAL CHARACTERISTICS (continued) Rated peak withstand current (Ipk): Volume when packed:. 25kA at 400V Volume (dm³) Rated short-time current (Icw):. 6 ka per 0,1 s. 2,5 ka per 0,3 s. 2 ka per 1 s Rated impulse withstand voltage:. Uimp = 4kV according to IEC 61439-2, 61439-3 Maximum power loss at 125 A (W):. 17,4 W for the distribution busbar 24 modules (cat. n 4 052 40).. 26,4 W for the distribution busbar 36 modules (cat. n 4 052 41) Maximum power loss at 80 A (W):. 7,1 W for the distribution busbar 24 modules (cat. n 4 052 40).. 10,8 W for the distribution busbar 36 modules (cat. n 4 052 41) Rated insulation voltage: Distribution busbar 24 modules (pack per 5) 3,3 Distribution busbar 24 modules (pack per 5) 4,8 Supply module + Power supply security module (pack. per 1) 0,75 Connection module 1P (pack. per 10) 0,75 Connection module 1P+N, in bag of 3 pieces (pack. per 5 bags) 0,995 Accessory for mounting in XL3 160 enclosure 3,675 Ambient operating temperature:. Ui = 500 V according to IEC 60493-1. Min. = -25 C. Max. = +70 C Pollution degree: Ambient storage temperature:. 2.. Min. = -40 C. Max. = +70 C Plastic materials:. All insulating parts (distribution busbar, supply module, connection modules 1P+N, 1P) comply with the glow-wire wire test (IEC/EN 606952-11). Horizontal distribution busbar is made of self-extinguishing extinguishing materials in accordance with the standard IEC/EN 60695-11 11-10. Higher calorific value (HCV):. Distribution busbar 24 modules: 3,112 MJ. Distribution busbar 36 modules: 4,738 MJ. Connection module (1P and 1P+N): 0,159 MJ. Power supply module: 0,636 MJ. Power supply security module: 0,154 MJ Protection index:. Protection index against solid and liquid bodies: IP 20 (IEC 529, EN 60529 et NF C 20-010). Resistance to sinusoidal vibrations:. According to IEC 60068-2-35.. Axis: x, y, z.. Frequency range: 5 100 Hz; duration 90 minutes. Displacement (5 13,2 Hz): 1mm.. Acceleration (13,2 100 Hz): 0,7g (g=9,81 m/s 2) Average weight of each element of the system:. Distribution busbar 24 modules: 0,501 kg. Distribution busbar 36 modules: 0,675 kg. Power supply module: 0,136 kg. Connection module 1P: 0,010 kg. Connection module 1P+N: 0,019 kg.. Power supply security module: 0,033kg 8/9

6. COMPLIANCE AND APPROVALS Compliance to standards:. Reference standard: IEC 61439 Environment respect Compliance with CEE directives:. Compliance with Directive 2002/95/EC of 27.1.2003 called "RoHS" provides the banishment of hazardous substances such as lead, mercury, cadmium, hexavalent chromium, brominated flame retardants polybrominated biphenyls (PBB) and polybrominated diphenylethers (P (PBDE) from 1 July 2006. Compliance with Directives 91/338/CEE E of 18/06/91 and decree 94-647 94 of 27/07/04.. Compliance with Directives 73/23/CEE and 93/68/CEE (DBT).. Compliance with Directives 83/336/CEE, 92/31/CEE and 93/68/CEE (CEM) Plastic materials:. Halogen-free plastic materials.. Marking of parts according ng to ISO 11469 and ISO 1043. Packaging:. Design and manufacture of packaging in accordance with decree 98-638 98 638 of 20.07.1998 and Directive 94/62/EC. 9/9