MULTI 9 System Catalog

Similar documents
60103 Circuit Breaker

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

MULTI 9 System Catalog

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Multi 9 System Catalog

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

Section 4 Ground-Fault Protection Devices

Miniature Circuit Breakers and Supplementary Protectors. Contents

UL 489 DIN rail branch circuit breakers

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers

Applying branch circuit breakers and supplementary protectors in North America

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

1492-SP Supplementary Protectors

Applying branch circuit breakers and supplementary protectors in North America

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

Bulletin 1489 Circuit Breakers. Selection Guide

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

Product Guide. UL 1077 DIN Rail Supplementary Protectors

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

WMS SUPPLEMENTARY PROTECTORS

Product Guide. UL 489 DIN rail miniature circuit breakers

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

9926 Series Branch Rated Circuit Breakers AC Version

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

Introduction Circuit Protection

TeSys IEC Contactors and Overload Relays

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

C60 UL 489 / CSA C22.2 No IEC / GB

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Control Circuit and Load Protection Products

Supplemental Protectors

Allen-Bradley 1492-RCDA4A40

Selection Guide. Control Circuit and Load Protection

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Mini Contactors & Overloads

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Time Delay Values (E-Series)

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

C60 multi-standard range

Supplementary Circuit Protectors Type GSB63

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

SECTION DISCONNECT SWITCHES

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Bulletin 1492-MC 1492-MCGA, -MCEA 1492-SP

SECTION SWITCHBOARDS

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

Jtec 10kA Miniature Circuit Breaker

920 Remote Control (RC) Switches

Miniature Circuit Breakers for Railway Applications

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

IELR Rail-Mount Series Magnetic Circuit Protectors

APL/UPL, 205/295 Series Magnetic Circuit Protectors

E-Series General Specifications

Miniature Circuit-Breaker IEC Series 8562

Ground Fault Current Protection Devices Prevent Costly Production Shutdowns

Learning Module 9: Miniature Circuit Breakers and Supplementary Protectors. 101 Basic Series

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Surgelogic Surge Protective Devices LC, XR, and XW Series

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

ASCO 920 Remote Control (RC) Switches

Power-Style QED-2, Series 2 Low Voltage Switchboards

IELR Series

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Motor protection relays

Circuit Breakers Type CTI 25M, CTI 45MB

Circuit Protection Methods

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

Surgelogic. Surge Protective Devices (SPDs) Residential. Catalog 6671CT9701R08/

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

Overvoltage Protection

ABL8WPS24400 regulated SMPS - 3-phase V - 24 V - 40 A

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

Supplement to Instruction Manual

CS8 Industrial Control Relays

BSPD Surge Protective Devices

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

RATINGS AND SPECIFICATIONS

Complete UL/CSA Disconnect Switch Kits

Transcription:

MULTI 9 System Catalog Class 80 CONTENTS Page Schneider Electric Brands Section Introduction... Section UL Rated Protection Devices... Section IEC 097- Rated Protection Devices... Section IEC Rated Ground-fault Protection Devices... Section Accessories... 9 Section Additional System Devices... Section 7Dimensions... Section 8Time/Current Curves... 79 Section 9Current Limiting Curves... 8 Section Applications... 9 Index...

TABLE OF CONTENTS MULTI 9 System Catalog Table of Contents INTRODUCTION MULTI 9 Products for OEM Applications... Conformance to Standards... 7 UL RATED PROTECTION DEVICES Overview... UL 89 Listed C0N Circuit Breakers (AC)... UL 89 Listed C0N Circuit Breakers (DC)... 8 UL 89A Listed C0N Miniature Circuit Breakers for DC Telecommunication Applications... 9 UL 77 Recognized C0 Supplementary Protectors... 0 UL 77 Recognized NC0H Supplementary Protectors... IEC 097- RATED PROTECTION DEVICES DPN-N Phase + Neutral Circuit Breakers... IEC Rated C0 Miniature Circuit Breakers... IEC Rated NC0H Circuit Breakers... 9 IEC RATED GROUND-FAULT PROTECTION DEVICES Selection Table... IEC Rated ID Residual Current Switches... IEC Rated C0 VIGI Modules for Ground-fault Protection... IEC Rated NC0 VIGI Residual Current Circuit Breakers... DPN-N VIGI Residual Current Circuit Breakers... 7 ACCESSORIES Electrical Auxiliaries... 0 Comb Bus Bars... Device Shielding... Identification System... 8 Operation Devices... 9 Mounting Accessories... 0 ADDITIONAL SYSTEM DEVICES Overview... Status, Display and Control Accessories... 7 KAEDRA Weatherproof DIN Type Enclosures... 0 Mini PRAGMA DIN Type Enclosures... PRAGMA F DIN Type Enclosures... DIMENSIONS UL 89 Listed C0 Circuit Breakers... UL 89a Listed Circuit Breakers for DC Telecom Applications... UL Recognized Supplementary Protectors and IEC Rated Circuit breakers... IEC Rated Ground-Fault Products...7 Accessory Dimensions... 8 KAEDRA Weatherproof Mini-Enclosure Dimensions... 7 KAEDRA Weatherproof Enclosures... 7 MINI-PRAGMA Din Type Enclosure Dimensions... 77 PRAGMA F DIN Type Enclosures... 78 TIME/CURRENT CURVES UL 89 Listed Circuit Breakers... 79 UL 89A Listed Circuit Breakers... 79 UL 77 Recognized Supplementary Protectors... 80 IEC 097- Rated DPN-N and DPN-N VIGI Circuit Breakers... 8 IEC 097- Rated Circuit Breakers...8 99 00 Schneider Electric All Rights Reserved

Table of Contents CURRENT LIMITING CURVES UL Listed and UL Recognized Supplementary Protectors...8 IEC 097- Rated Circuit Breakers...89 APPLICATIONS Degree of Protection (IP)...9 Temperature Rating... 9 Typical IEC Grounding Systems... 98 INDEX... 99 00 Schneider Electric All Rights Reserved

Section Introduction SECTION INTRODUCTION MULTI 9 PRODUCTS FOR OEM APPLICATIONS Overview Applications System Flexibility The MULTI 9 modular system of miniature circuit breakers and supplementary protectors, accessories, and peripherals is ideal for use by OEMs to provide complete protection of equipment or especially sensitive circuits within the equipment. Installation labor and space are both minimized by the modular architecture of the MULTI 9 system, whether a single protective device or multiple devices with their accessories are being used. All MULTI 9 products are in compliance with applicable IEC Standards. Many are also compliant with UL Standard 77 as supplementary protectors or UL 89 as circuit breakers. To an OEM, this means that one family of electrical protection products can be used regardless of equipment destination. The Standards include: UL 89 Standard for Circuit Breakers UL 89A Standard for DC Communication Applications UL 77 Standard for Supplementary Protectors IEC 097- IEC 0898 CSA C. VDE 00 Potential applications include semi-conductor machines, communication equipment, computers, medical equipment, electronic controls, transformers, power supplies, and other electrical equipment. The MULTI 9 System includes an extensive line of field-installable accessories. Plug-on electrical auxiliaries include shunt trip, undervoltage release, auxiliary switch, and alarm switch. Other protection devices include residual current detectors, dc circuit breakers, and switches. Control and display devices include signal lamps, push buttons, and motor operators. There are also mechanical accessories for locking, operating, shielding, mounting, etc. See the following functional diagram, which shows many of the accessories of the MULTI 9 system. Figure : Functional Diagram of MULTI 9 System Status and Display Output Control Inputs 08077 CI Impulse Counter CH Hour Counter V Signal Lamp V Signal Lamp BP Push Button (N.O.) or Signal BP Push Button (N.C.) or Signal TM Motor Operator Switch or Control Metering Device SD Alarm Switch OF Aux Switch MX + OF Shunt Trip & Aux Switch MN Undervoltage Release C0N Circuit Breaker Vigi Residual Current Device Protected Line Plug-on Electrical Auxilliaries IH and IHP Time Switches I Switch CM Selector Switch DPN-N Residual Current Circuit Breaker OFS & Elect. Accessory ID Residual Current Device Other devices used with or instead of the C0N device 99-00 Schneider Electric All Rights Reserved

Section Introduction Advantages MULTI 9 C0 and NC0 circuit breakers and supplementary protectors provide several advantages which are important to OEMs. These include: Small, compact size Easy installation on DIN rails Current-limiting, to provide more protection to sensitive circuits Resetability, more convenient than fuses Communication capabilities for control and status information Extensive variety of accessories Figure : UL 89 Listed MULTI 9 C0 Circuit Breakers 080 -pole 080 -pole 0809 -pole Better ProtectionMULTI 9 supplementary protectors and miniature circuit breakers are current limiting, providing faster separation of the component from the fault, thereby reducing system damage. More SelectionMore ratings compatible with low-power electronic circuits are available in the range from 0. to A. Others are provided in convenient steps, up to A for the C0 and up to 80 A for the NC0 products. Reduction of Nuisance TrippingAvailable with different trip characteristics to meet system needs: B, C, D, and MA curves, depending on the model. Panel Space SavingsMULTI 9 products are compact. Width per pole is only 0.7 in. (8 mm) for the C0 circuit breaker and.0 in. (7 mm) for the NC0 circuit breaker. All of the products are built in a consistent format with incremental widths of 0. in. (9 mm) modules (therefore the name MULTI 9 ). Easy InstallationThe MULTI 9 modules mount easily onto a mm DIN mounting rail. Large box lug terminals (pressure plate type) are suitable for use with copper wiring up to # AWG (for C0 series) and # AWG for the NC0 series. Reverse Feeding Reverse feeding of line power is permitted. ReliabilityEach C0 miniature circuit breaker has an endurance of 0,000 operation cycles and voltage withstand of 000 V impulse rating. World-wide AvailabilityThe MULTI 9 products are available and supported throughout the world by Schneider Electric family, including Square D and Merlin Gerin. From the Power Distribution SpecialistsSquare D can be your single source of protection equipment, with a comprehensive line of products for OEM products or the factory. These other products include the following: QO and QOU Miniature Circuit Breakers A COMPACT Molded Case Circuit Breakers 00 A POWERPACT Electronic Trip Circuit Breakers 0 00 A MASTERPACT Universal Power Circuit Breakers 0 00 A 99-00 Schneider Electric All Rights Reserved

Section Introduction CONFORMANCE TO STANDARDS Overview Conformance to Standards most needed by OEMsUL 89, UL 77 and IEC 097-. Different applications call for circuit protection devices that meet different standards. The MULTI 9 family allows OEMs to use a single family of products in their equipment, whether it is destined for the United States or for a foreign market. A variety of MULTI 9 devices are tested per Underwriters Laboratories (UL) Standards that are required by the National Electrical Code (NEC ) in the United States. They are also tested per the standards of the International Electrotechnical Commission (IEC ) and may therefore be used in many foreign countries as these products meet both standards. In this catalog, the products are grouped by the standards they are designed to meet. These standards include the following: UL 89Defines rigorous testing requirements for circuit breakers in the United States UL 89ALimited applications (dc circuits in communications equipment) UL 77Defines supplementary protectors for use within electrical equipment protected by branch circuit breakers IEC 097-International standards for circuit breakers to be used in industrial applications UL 89 Standard Branch Circuit Protection An OEM product as a whole must be appropriately protected from overcurrent conditions, either by connection in the field to a protected branch circuit (in accordance with NEC) or by inclusion of branch circuit protection within the product itself. In the United States, these branch circuit protection devices must comply with the UL 89 Standard for Molded-Case Circuit Breakers. (see UL 89 # in Figure, which is a drawing of a hypothetical piece of OEM equipment requiring multiple protection devices.) Applications Requiring UL 89 Standards In some instances, the protective devices being installed in equipment must comply with UL 89. These include the following situations:. If a circuit such as a convenience receptacle leaves the equipment, that circuit must be protected by a UL 89 branch circuit protection device (see UL 89 #).. If a circuit such as to an external motor leaves the equipment, that circuit must be protected by a UL 89 branch circuit protection device (see UL 89 #).. Motors within the equipment should also be protected by a UL 89 device (see UL 89 #).. All equipment which requires HACR (Heating, Air Conditioning, and Refrigeration) rating must be protected by a UL 89 branch circuit protection device (see UL 89 #). NOTE: The motor control circuit may be protected by a UL 77 device. In general, a UL 89 circuit breaker could also be used in any application for which a UL 77 device is allowed, since the UL 89 devices meet or exceed the requirements of UL 77 devices. The converse of this is not true, since UL 77 devices cannot meet the more stringent UL 89 Standards. UL 77 Standard Supplementary Protection within the Product Within the OEM product itself, additional (supplementary) protection for sensitive or critical internal circuitry may be provided by one or more supplementary circuit protectors. A supplementary protector is an overcurrent protection device which is specifically designed for OEM applications and which complies with UL 77 Standard for Supplementary Protectors for Use in Electrical Equipment. Under UL 77, supplementary protectors may be used under the following conditions: When branch overcurrent protection is already provided If short-circuit protection is needed for sensitive devices within the equipment When wiring connected to the supplementary protector does not exit the equipment to external devices such as receptacles or motors If the UL 77 device does not provide the only means of disconnecting the product 99-00 Schneider Electric All Rights Reserved 7

Section Introduction The following applications illustrated in Figure allow the use of UL 77 supplementary protectors: The supplementary protection is used to supplement or provide additional protection to sensitive components inside the equipment (see UL 77 #). A UL 89 circuit breaker must be located upstream from the equipment. Critical or sensitive internal circuitry (see UL 77 #) such as: Computers and microprocessors, communications equipment, electronic controllers, power supplies and many other types of equipment Motor control circuits may be protected by a UL 77 device, unless the circuit includes a transformer (in which case a UL 89 device is required). Comparing Terminology for UL 89 and 77 Standards The terms used to differentiate these products can cause confusion if a user is not careful. Misapplying the terms may result in misapplication of the products. Any one of the following terms can be used to identify supplementary protectors: Supplementary protector UL Recognized UL 77 The reverse UR symbol Any of the following terms can be used to identify circuit breakers: Circuit breaker UL Listed UL 89 The UL symbol UL 89A Standard UL 8 Standard IEC 097- Standard IEC 898 Standard CSA C. Standard DC Communication Applications The 89A Standard covers dc rated circuit breakers intended to provide branch circuit protection in communications equipment. The products are marked as UL Listed circuit breakers for use in communication equipment. Connection Terminals The UL 8 Standard applies to compression wiring connection terminals. It is a requirement for connections of a UL 89 circuit breaker. Although it is not a requirement for UL 77 Recognized devices, UL 8 Rated terminals are included on those MULTI 9 products. This allows the user to apply field wiring directly to any of these devices, without using intermediate, UL rated terminal blocks. The connectors on MULTI 9 devices are Rated UL 8A, which applies to copper conductors. These standards apply to field-wired terminals that are an integral part of the equipment. Criteria includes static heating tests, secureness tests, and pull-out tests. In countries which follow the IEC Standards, IEC 097- is used for most industrial applications of circuit protection. IEC 097- does not distinguish between the two levels of protection equivalent to UL 89 circuit breakers and 77 supplementary protectors. Therefore, in equipment like that illustrated in figure, if IEC guidelines apply, then all of the devices could be selected from the IEC Rated portion of this catalog. The IEC 898 Standard is less stringent than 097-. It applies primarily to residential applications of circuit breakers in countries adhering to IEC Standards, and is not generally applicable to OEMs. The CSA (Canadian Standards Association ) C. Standards closely correspond to the UL Standards: CSA C. No. -0 (equivalent to UL 89) and CSA C. No. (equivalent to UL 77). 8 99-00 Schneider Electric All Rights Reserved

Section Introduction UL 08 Standard Industrial Control EquipmentManual Motor Controllers UL Standard 08 covers industrial control equipment, specifically for motor control functions. It covers individual devices as well as assemblies. There are UL 08 Listed manual motor controllers that look much like miniature circuit breakers, and have thermal settings and instantaneous settings similar to circuit breakers. These are specialized devices and cannot be used for a wide range of applications, as can UL 77 and 89 devices. Like UL 77 supplementary protectors, a UL 08 Listed manual motor controller (or a group of them) must be protected by a UL 89 branch circuit breaker. These manual motor controllers are available from Schneider Electric (Telemecanique products GV and GV) but are not included in this catalog. Figure : Guidelines for Application of UL 89 Circuit Breakers and UL 77 Supplementary Protectors Feeder or Branch Circuit UL 89 Listed Molded Case Circuit Breaker (MCCB) or Miniature Circuit Breaker (MCB) 080 UL 77 Applications Permitting Supplementary Protectors Miscellaneous Devices Protected by Branch Circuit Breaker UL 89 Internal Receptacle External Receptacle Supplements or provides additional protection for sensitive electronics inside the equipment. Used on the load side of branch circuit protection to protect critical or sensitive internal circuitry such as: Computers and microprocessors Communications equipment Electronic controllers Power supplies Many other types of equipment UL 77 UL 89 External Motor Permitted for protection of motor control circuits NEC 0-7, unless transformers are in circuit, then UL 89. Electronics UL 89 Applications Requiring Branch Circuit Protection Other Sensitive Devices UL 77 UL 89 Motor Control Internal Motor Protects conductors entering the OEM equipment. This required UL 89 device may be provided integral to the OEM equipment or be external as part of the distribution system. May act as branch circuit protection if it protects the conductor to the utilization equipment. Required to protect convenience receptacle circuits (internal or external) Required to protect an external load circuit leaving the equipment HACR UL 89 UL 77 Required for motors in the equipment Required for HACR equipment (Heating, Air Conditioning, and Refrigeration) Equipment Enclosure NOTE: This is a simplified summary of the standards. Refer to applicable codes for specific applications. 99-00 Schneider Electric All Rights Reserved 9

Section Introduction Table : Comparison Summary of Applicable UL and IEC Standards Characteristic UL 89 UL 77 IEC 097- Labeling UL Listed UL Recognized component IEC Certified device Nomenclature Circuit breakers Supplementary protectors Circuit breakers or supplementary protectors Dielectric test (for 0 Vac) times rated plus 00 V for minute (,80 at 0 Vac) times rated plus,000 V for minute (,80 at 0 Vac) Interrupting rating,000 ka at 0 Vac,000 ka at 0 Vac 0,000 ka at 0 Vac Overload protection 0 operations at 00% rating 0 operations at 0% rating operations at 00% rating Service capacity Must be operational after two interruptions May be tested in series with branch circuit device and may become inoperable after test Calibration test 00% I n, minutes max. (0 0 A) Per manufacturer s trip curve Calibration temperature Testing temperature Endurance 77 F ( C), unless other value specified by manufacturer 77 F ( C) ambient, F (0 C) rise max. at terminals At rated current and voltage, 7 80% PF,,000 operations +,000 no load Manufacturer must specify 77 F ( C) ambient, F (0 C) rise max. at field wiring terminals; 9 F ( C) rise max. on factory wiring terminals At rated current and voltage, 7 80% PF,,000 operations,00 V Same as UL 89 At 00% I n, time shall not exceed manufacturer s stated value Manufacturer must specify Air spacing / in. (0. mm) /8 in. (9. mm) See dielectric Surface spacing -/ in. (.8 mm) / in. (.7 mm) See dielectric Test and follow up tests Initial, periodic and quarterly follow-up tests observed by UL representative Initial tests observed by UL representative, plus quarterly visual follow-up inspection by UL At 77 F ( C) ambient, 7 F (80 C) rise max. at terminals At rated current and voltage, 7 80% PF,,00 operations Conducted by manufacturer Labels and Markings Figure : Labels and Markings for UL 89 Listed and CSA... Certified C0N Circuit Breakers (AC Only). Circuit Breaker Type. Ampere Rating. Trip Curve. Voltage. Standards Marks. Standards Marks 7. Catalog Number 8. UL File Number 9. CSA File Number. Wire Characteristics. Torque. Interrupting Ratings as per UL 89 and VDE 00. Interrupting Ratings as per IEC 097- and VDE 00 0800 0 Vac 7 Face Markings MERLIN GERIN multi 9 C0N 0.A-type C LISTED C.B. ISSUE No. L-77 Cat. No. 00 IEC Side Markings (Box/Box Terminals) 8 9 UL File : E7 0VAC AIR ka (P) CSA File : 790 0VAC AIR ka (P) 0VAC AIR ka (-P) MADE IN FRANCE 7 C WIRE # - # 8 AWG TERMINAL SCREW TORQUE lb-in /.8 N m 0VAC AIR 0kA IEC 097- / VDE 00 VAC AIR ka Side Markings (Ring/Ring Terminals) Side Markings (Box/Ring Terminals) 8 9 UL File : E7 0VAC AIR ka (P) CSA File : 790 0VAC AIR ka (P) 0VAC AIR ka (-P) MADE IN FRANCE 7 C WIRE # - # 8 AWG RING TONGUE TERMINAL TORQUE 8 lb-in /.0 N m 0VAC AIR 0kA IEC 097- / VDE 00 VAC AIR ka 8 9 UL File : E7 0VAC AIR ka (P) CSA File : 790 0VAC AIR ka (P) 0VAC AIR ka (-P) MADE IN FRANCE 7 C WIRE # - # 8 AWG TERMINAL SCREW TORQUE lb-in /.8 N m RING TONGUE TERMINAL 0VAC AIR 0kA IEC 097- / VDE 00 VAC AIR ka NOTE: Labels shown are for information only. Actual products may differ. 99-00 Schneider Electric All Rights Reserved

Section Introduction Figure : Labels and Markings for UL 89 Listed C0N DC Circuit Breakers (Dual Rated AC and DC). Circuit Breaker Type. Ampere Rating. Trip Curve. AC Voltage. DC Voltage. Standards Marks 7. Catalog Number 8. UL File Number 9. CSA File Number. Wire Characteristics. Torque. Interrupting Ratings as per UL 89 and VDE 00. Interrupting Ratings as per IEC 097- and VDE 00 Side Markings (Box/Box Terminals) 8 E7 / 790 (~) E7 / 790 ( ) 0VDC AIR 000A (P) C Curve li: 7... In VDC AIR 000A (P) li: 7... In IEC 097-/VDE 00 0VDC AIR 000A 7 C WIRE # - #8 AWG (- mm ) TORQUE LB-IN/.8 N m 080 Face Markings 0 V 7 -pole MERLIN GERIN multi 9 C0N C 0A LISTED C.B. ISSUE No. L-77 Cat. No. 00 IEC Side Markings (Box/Ring Terminals) 8 9 UL File : E7 0VAC AIR ka (P) CSA File : 790 0VAC AIR ka (P) 0VAC AIR ka (-P) MADE IN FRANCE 7 C WIRE # - # 8 AWG TERMINAL SCREW TORQUE lb-in /.8 N m RING TONGUE TERMINAL 0VAC AIR 0kA IEC 097- / VDE 00 VAC AIR ka -pole 7 MERLIN GERIN multi 9 C0N C 0.A LISTED C.B. ISSUE No. L-77 Cat. No. 0 V IEC + LOAD in. MIN 8 9 Side Markings (Ring/Ring Terminals) UL File : E7 0VAC AIR ka (P) CSA File : 790 0VAC AIR ka (P) 0VAC AIR ka (-P) MADE IN FRANCE 7 C WIRE # - # 8 AWG RING TONGUE TERMINAL TORQUE 8 lb-in /.0 N m 0VAC AIR 0kA IEC 097- / VDE 00 VAC AIR ka NOTE: Labels shown are for information only. Actual products may differ. 99-00 Schneider Electric All Rights Reserved

Section Introduction Figure : Labels and Markings for UL 89A Listed Circuit Breakers (Dual Rated 89A for DC Telecom and UL 77 for Supplementary Protector Applications). Circuit Breaker Type. Ampere Rating. Trip Curve. AC Voltage. Standards Marks. Catalog Number 7. UL 89A Label 8. UL 89A File Number 9. Torque. Wire Characteristics. Interrupting Ratings as per UL 89A. Interrupting Ratings as per UL 77. IEC and VDE Standards. Interrupting Ratings as per IEC 097- and VDE 00. Country of Origin. Magnetic Release for Trip Curve Top Markings (0. A) LISTED C.B. FOR USE IN COMM EQUIP ISSUE NO. L-0 7 Side Markings (0. A) 8 9 TORQUE LB-IN (. N m) 7 C WIRE # - # AWG (- mm ) UL 89A L-0/L07 --- 0VDC AIR KA UL77 E9008 / CSA 790 0VAC AIR KA 0VDC AIR KA 77VAC AIR KA (P) IEC097- / VDE 00 MADE IN FRANCE 0VAC AIR 0KA 0VDC AIR KA 0VAC AIR KA C Curve li: 7... In li: 7... In 080 Face Markings MERLIN GERIN multi 9 C0N A-type C 77 Vac Cat. No. XXXXX IEC Top Markings (0 A) LISTED C.B. FOR USE IN COMM EQUIP ISSUE NO. L-07 7 8 9 Side Markings (0 A) TORQUE LB-IN (. N m) 7 C WIRE # - # AWG (- mm ) UL 89A L-0/L07 --- 0VDC AIR KA UL77 E9008 / CSA 790 0VAC AIR KA 0VDC AIR KA 77VAC AIR KA (P) IEC097- / VDE 00 0VAC AIR 0KA 0VAC AIR KA C Curve li: 7... In MADE IN ITALY 0VDC AIR KA li: 7... In Figure 7: Labels and Markings for UL 77 C0N Supplementary Protectors. Supplementary Protector Type. Ampere Rating. Trip Curve. Voltage. Standards Marks. Catalog Number 7. UL 77 File Number 8. CSA File Number 9. Wire Characteristics. Interrupting Ratings as per IEC 097- and VDE 00. Interrupting Ratings as per UL 77 080 Face Markings MERLIN GERIN multi 9 C0N A-type C 77 Vac Cat. No. XXXXX IEC 7 8 9 E9009 77VAC INT RATING 000A 790 0VAC INT RATING 000A 0VDC INT RATING 000A LINE-LOAD CAN BE REVERSED MADE IN XXXXXXX --- MAX 00VAC TO GROUND IEC 097. 0000A AT 0V AC VDE 00 000A AT 0V AC 7 O C WIRE # - #8 AWG (- mm) TORQUE lb-in (.8 N m) Side Markings Figure 8: Labels and Markings for UL 77 NC0 Supplementary Protectors. Supplementary Protector Type. Ampere Rating. Trip Curve. Voltage. Standards Marks. Catalog Number 7. UL 77 File Number 8. CSA File Number 9. Interrupting Ratings as per IEC 097- and VDE 00. Interrupting Ratings as per UL 77 080 Face Markings MERLIN GERIN multi 9 NC0 80 Vac IEC Cat. No. XXXXX 0A-type C 7 8 EXXXXX 80VAC INT RATING 000A XXXXXX 0VAC INT RATING 0000A LINE-LOAD CAN BE REVERSED MADE IN FRANCE--- MAX 00V AC TO GROUND IEC 097- XXXXXX A AT 0V (ou V) VDE 00 XXXXXX A AT 0V (ou V) Side Markings 9 NOTE: Labels shown are for information only. Actual products may differ. 99-00 Schneider Electric All Rights Reserved

SECTION UL RATED PROTECTION DEVICES MULTI 9 System Catalog Section UL Rated Protection Devices OVERVIEW The MULTI 9 system includes four families of miniature circuit protection devices that have the UL Ratings required in the United States and some other countries. The products are summarized below and are described in detail on the following pages. They include the following families: UL Listed C0 Circuit Breakers (UL 89) UL Listed C0 Circuit Breakers for use in Communication Equipment (UL 89A) UL Recognized C0 and NC0 Supplementary Protectors (UL 77) NOTE: IEC Rated protection devices are described in Sections and, while accessories for both the UL and IEC devices are described in Section. Table : Selection Table for UL 89 and 89A Listed C0 Circuit Breakers Ratings per UL Standards UL 89 C0N (AC) UL 89 C0N (DC) UL 89A C0N (DC) Number of poles Rated current (A) at 77 F ( C) 0. 0. 0. 0. 0. 0. Interrupting ratings as per UL 89 (ka RMS) AC 0/0 Hz DC 0 V 0 V 77 V 80Y/77 V 0 V V Ultimate breaking capacity (I cu ) as per IEC 097- (ka RMS) AC 0/0 Hz 0 V V 0 V 0 0 0 0 0 Service breaking capacity (I cs ) (%I cu ) 7% 7% 7% 7% 7% 7% Trip Units B curve Magnetic setting (times ampere rating) C curve Between 7 and times ampere rating 7 to 7 to 7 to D curve Between and times ampere rating Dimensions and Weights Dimensions (in./mm) Weight (oz./g) max. Width 0.7/8././ 0.7/8./ 0.7/8 Height box/box ring/ring box/ring./7.8/.././7.8/.././7.8/.././7.8/.././7.8/../.9/8.8/../ Depth.00/7.00/7.00/7 box/box./ 8.7/7./07./ 8.7/7.8/ ring/ring./././8././ box/ring.8/8 9./97./.8/8 9./97 Figure 9: UL 89 Listed MULTI 9 C0 Circuit Breakers -Pole -Pole -Pole 99-00 Schneider Electric All Rights Reserved

MULTI 9 System Catalog Section UL Rated Protection Devices Table : Selection Table for UL 77 Recognized Supplementary Protectors Ratings per UL Standards UL 77 C0N UL 77 NC0 Number of poles Rated current (A) at 77 F ( C) 0. 0. 0. 0. 0 0 80 0 0 80 0 0 80 0 0 80 Interrupting ratings as per UL 77 (ka RMS) 0/0 Hz 0 Vac 0 Vac 77 Vac 80Y/77 Vac Vdc Vdc Ultimate breaking capacity (I cu ) as per IEC 097- (ka RMS) 0/0 Hz 0 Vac Vac 0 Vac 0 0 0 Service breaking capacity (I cs ) (%I cu ) 7% 7% 7% 7% Trip Units 0 0 0 0 0 0 0 0 0 0 B curve Magnetic setting C curve D curve Dimensions and Weights Between. and.8 times ampere rating Between 7 and times ampere rating (between 7 and for dc) Between and times ampere rating (no dc rating for D curve) Dimensions (in./mm) Width Height Depth 0.7/8.9/8.00/7./.9/8.00/7./.9/8.00/7.8/7.9/8.00/7.0/7.9/8.00/7./.9/8.00/7.9/8.9/8.00/7./8.9/8.00/7 Weight (oz./g).8/ 7.70/0./ 0.0/ 0./80.70/0 9.0/0./70 Figure : UL 77 Recognized C0N Supplementary Protectors 0800 080 -Pole -Pole -Pole -Pole 080 080 Figure : UL 77 Recognized NC0H Supplementary Protectors 08000 -Pole -Pole -Pole -Pole 0800 0800 0800 99-00 Schneider Electric All Rights Reserved

MULTI 9 System Catalog Section UL Rated Protection Devices UL 89 LISTED C0N CIRCUIT BREAKERS (AC) Overview A family of circuit breakers meeting UL 89 requirements is now available in the MULTI 9 product line. These products meet many applications in which UL 77 Recognized supplementary protectors are not allowed. As shown in the table of catalog numbers below, the UL 89 Listed products are available in C and D curves. They include devices ranging from 0. to A. Standard Features Fast closing: Allows increased withstand to the high inrush currents of some loads. Trip-free mechanism: Contacts cannot be held in the on (O) position when the C0 circuit breaker is tripped automatically. Positive indication of contact disconnect. Green mechanical indication on front face of device shows that all poles are open. C curve: Overcurrent protection for all application types. Magnetic release operates from 7 to times ampere rating. (7 to for dc) D curve: Overcurrent protection for loads with high inrush currents (motors, transformers). Magnetic release operates between and times ampere rating (no dc rating for D curve). Suitable for reverse feeding Allows locking in OFF position using padlock attachment. Connections Two versions of field wiring connectors are available for the UL 89 Listed devices: Box lug meeting UL 8A requirements Ring tongue terminal with mm screw The circuit breakers can be ordered with the following combinations of connectors: Line terminal box lug/load terminal box lug Line terminal ring tongue/load terminal ring tongue Line terminal box lug/load terminal ring tongue Figure : Connection Options for UL 89 Listed Devices Box Lug Ring Tongue Box Lug Box Lug Ring Tongue Ring Tongue 99-00 Schneider Electric All Rights Reserved

MULTI 9 System Catalog Section UL Rated Protection Devices Specifications Table : Specifications for UL 89 Listed C0 Circuit Breakers Ratings per UL Standards UL 89 C0N (AC) Number of poles Rated current (A) at 77 F ( C) 0. 0. 0. Interrupting ratings as per UL 89 (ka RMS) AC 0/0 Hz 0 V 0 V 77 V 80Y/77 V Ultimate breaking capacity (I cu ) as per IEC 097- (ka RMS) AC 0/0 Hz 0 V V 0 V 0 0 0 Service breaking capacity (I cs ) (%I cu ) 7% 7% 7% Trip Units Magnetic setting (times ampere rating) Dimensions and Weights B curve C curve D curve Between 7 and times ampere rating (7 and for dc) Between and times ampere rating Width 0.7/8././ Dimensions (in./mm) Weight (oz./g) max. Height box/box ring/ring box/ring./7.8/.././7.8/.././7.8/../ Depth.00/7 box/box./ 8.7/7./07 ring/ring./././8 box/ring.8/8 9./97./ Table : Additional Specifications for UL 89 Listed Circuit Breakers High voltage withstand: kv Rating on box lug connector: UL 8A File #E99 (use with copper wire only) Connection, box lug: 0. A: #8 # AWG ( mm ) cables; torque lb-in. (.8 N m) 0 A: #8 # AWG ( mm ) cables; torque lb-in. (. N m) Connection, ring terminal: Use single UL Listed or CSA Certified insulated ring tongue only, with screw dia. 0. in. ( mm); torque 8 lb-in. (.0 N m) Max ring terminal width. 0. in. ( mm) Mounting: mm DIN rail Degree of protection: Case: IP0 as per IEC 9 Terminals: IP0 Temperatures: Calibration: 77 F ( C) Storage: -0 to 7 F (-0 to 80 C) Operating: - to 8 F (-0 to 70 C) Tropicalization: Treatment relative humidity: 9% at F ( C) Number of operating cycles: Electrical (O-C):,000 load,,000 no-load See specifications table for weights and interrupting ratings Standards UL 89 Circuit Breaker: File #E7 Single pole 0 A is UL Listed as SWD (switching duty). -, -, and -pole A are HID (high intensity discharge) rated. CSA C. #. Circuit Breakers: File #790 IEC 097- VDE 00 CE Marked 99-00 Schneider Electric All Rights Reserved

Catalog Numbers Table : C Curve, UL 89 Listed Miniature Circuit Breakers (AC) (line/load as box lug or ring tongue terminals) MULTI 9 System Catalog Section UL Rated Protection Devices Rating (A) -pole -pole -pole 0.. 7 8 0 0 Box/Box Ring/Ring Box/Ring Box/Box Ring/Ring Box/Ring Box/Box Ring/Ring Box/Ring 00 000 000 0 0 0 0 00 00 0 0 0 08 08 08 0 00 00 0 0 0 09 09 09 0 00 00 07 07 07 070 070 070 0 00 00 08 08 08 07 07 07 0 00 00 09 09 09 07 07 07 0 00 00 00 00 00 07 07 07 07 007 007 0 0 0 07 07 07 08 008 008 0 0 0 07 07 07 09 009 009 0 0 0 07 07 07 0 0 0 0 0 0 077 077 077 0 0 0 0 0 0 078 078 078 0 0 0 0 0 0 079 079 079 0 0 0 07 07 07 080 080 080 0 0 0 08 08 08 08 08 08 0 0 0 09 09 09 08 08 08 0 0 0 00 00 00 08 08 08 Table 7: D Curve, UL 89 Listed Miniature Circuit Breakers (AC) (line/load as box lug or ring tongue terminals) Rating (A) -pole -pole -pole Box/Box Ring/Ring Box/Ring Box/Box Ring/Ring Box/Ring Box/Box Ring/Ring Box/Ring 0.. 07 08 09 07 08 09 07 08 09 0 0 0 0 0 0 0 0 0 08 08 08 08 08 08 00 0 0 00 0 0 00 0 0 0 0 0 0 0 0 0 0 0 08 087 088 08 087 088 08 087 088 7 0 0 0 0 0 0 0 0 0 07 08 09 07 08 09 07 08 09 089 090 09 089 090 09 089 090 09 8 0 07 08 0 07 08 0 07 08 00 0 0 00 0 0 00 0 0 09 09 09 09 09 09 09 09 09 0 09 00 0 09 00 0 09 00 0 0 0 0 0 0 0 0 0 0 09 09 097 09 09 097 09 09 097 0 0 0 0 0 0 0 098 098 098 0 0 0 07 07 07 099 099 099 NOTE: The UL 89 Listed MULTI 9 C0N circuit breakers are certified at 77 F ( C), unlike some other UL 89 circuit breakers which are certified at F (0 C). Depending on the operating environment, you may need to rerate according to the tables on page 9 to determine the appropriate handle rating. NOTE: UL 89 Listed circuit breakers should be loaded to no more than 80% if used with continuous loads; that is unlike UL 77 recognized supplementary protectors, which may be operated at 0% of rating. 99-00 Schneider Electric All Rights Reserved 7

MULTI 9 System Catalog Section UL Rated Protection Devices UL 89 LISTED C0N CIRCUIT BREAKERS (DC) Overview A portion of the range of UL 89 MULTI 9 circuit breakers is also Listed by UL for use with dc circuits. The specifications are the same as the UL 89, with the following exceptions: Number of poles: and Time/Current Curve: C curve Magnetic setting of C curve: Between 7 and times ampere rating DC voltage (nominal): -pole0 Vdc, -pole Vdc Connection: Box Lug only (same torque) Specifications Table 8: Specifications for UL 89 DC Circuit Breakers Ratings per UL Standards UL 89 C0N (DC) Number of poles Rated current (A) at 77 F ( C) 0. 0. Interrupting ratings as per UL 89 0 V DC (ka RMS) V Service breaking capacity (I cs ) (%I cu ) 7% 7% Trip Units Magnetic setting (times ampere rating) B curve C curve D curve 7 to 7 to Dimensions and Weights Width 0.7/8./ Dimensions (in./mm) Height box/box./7./7 Depth.00/7 Weight (oz./g) max. box/box./ 8.7/7 Catalog Numbers Table 9: C Curve, UL 89 Listed Miniature Circuit Breakers (DC) Rating (A) -pole -pole Box/Box Box/Box 0.. 7 8 0 0 0 0 0 00 0 0 0 0 0 0 07 0 08 0 09 0 00 07 0 08 0 09 0 0 0 0 0 0 0 0 07 0 08 0 09 0 00 Availability to be Announced The dc catalog numbers are the same as UL 89 ac equivalents. 8 99-00 Schneider Electric All Rights Reserved

MULTI 9 System Catalog Section UL Rated Protection Devices UL 89A LISTED C0N MINIATURE CIRCUIT BREAKERS FOR DC TELECOMMUNICATION APPLICATIONS Overview 0800 A limited range of the UL 77 C0N supplementary protectors are also UL Listed as UL 89A circuit breakers for protection of dc telecommunications circuits. The specifications are the same as the UL 77 C0N, with the following exceptions: Number of poles: only Time/Current Curve: C Curve Magnetic settings of C Curve: Between 7 and times ampere rating DC voltage (nominal): -pole0 Vdc Connection: Box Lug only (same torque) Catalog Numbers Table : UL 89A Circuit Breakers for DC Telecommunications Applications Rating (A) C Curve -pole Modules Rating (A) C Curve -pole Modules Rating (A) C Curve -pole Modules 0... MG7 MG MG7 MG7 7 8 MG0 MG7 MG MG 0 MG MG77 MG7 MG78 MG MG7 MG8 MG7 0 MG MG7 MG MG 0 0 0 MG8 MG9 MG79 MG0 NOTE: These catalog numbers are the same as their UL 77 equivalents. 99-00 Schneider Electric All Rights Reserved 9

MULTI 9 System Catalog Section UL Rated Protection Devices UL 77 RECOGNIZED C0 SUPPLEMENTARY PROTECTORS Overview A family of MULTI 9 supplementary protectors meeting the UL 77 Standard is available. These UL 77 products are intended for use as supplementary protectors to provide overcurrent protection within appliances or electrical equipment where branch circuit protection is already provided or is not required. As shown in the table of catalog numbers below, the UL 77 Recognized products are available in B, C and D curves. They include devices ranging from 0. A to A. (For higher current ratings, select devices from the higher current NC0 series.) Figure : UL 77 Recognized C0N Supplementary Protectors 0800 080 080 080 -Pole -Pole -Pole -Pole Standard Features Trip-free mechanism: Contacts cannot be held in the on position when the C0 is tripped automatically. Positive indication of contact disconnect. Green mechanical indication on front face of device shows that all poles are open. B curve: Overcurrent protection for sensitive equipment (computers, electronic devices, etc.). Magnetic release operates between. and.8. (between. and.8 for dc) C curve: Overcurrent protection for all application types. Magnetic release operates from 7 to times ampere rating. (between 7 and for dc) D curve: Overcurrent protection for loads with high inrush currents (motors, transformers). Magnetic release operates between and times ampere rating. (no dc rating) Allows locking in OFF position using padlock attachment. Suitable for reverse feeding. NOTE: Other features of the UL 77 Recognized C0 circuit breaker are identical to those of the UL 89 version. A variety of accessories are available for these products. Table : Specifications for UL77 Recognized C0 Supplementary Protectors Package size: 0.7 in. (8 mm) width per pole Voltage (nominal): 80Y/77 Vac High voltage withstand: kv Connection, box lug 0. A: #8 # AWG ( mm ) cables; torque lb-in (.9 N m) 0 A: #8 # AWG ( mm ) cables; torque lb-in (.0 N m) Connection, ring terminal kit: Use Cat. No. 700 Mounting: mm DIN rail Time-current curves: B, C, and D curves Degree of protection as per IEC8--0: Case: IP0 as per IEC 9 Terminals: IP0 Rating on connector: UL 8A File #E9009 pending; use with copper wire only. Screw dia.: 0. in. (mm); torque 8 lb-in (.0 N m) Temperatures: Calibration: 77 F ( C) Storage: -0 to 7 F (-0 to 80 C) Operating: to 8 F (-0 to 70 C) Tropicalization: Treatment relative humidity: 9% at F ( C) Number of operating cycles electrical (O-C):,000 at 0. A See selection table for weights and interrupting ratings 0 99-00 Schneider Electric All Rights Reserved

MULTI 9 System Catalog Section UL Rated Protection Devices Table : Selection Table for UL 77 Recognized Supplementary Protectors Ratings per UL Standards UL 77 C0N UL 77 NC0 Number of poles Rated current (A) at 77 F ( C) 0. 0. 0. 0. 0 0 80 0 0 80 0 0 80 0 0 80 Interrupting ratings as per UL 77 (ka RMS) 0/0 Hz 0 Vac 0 Vac 77 Vac 80Y/77 Vac Vdc Vdc Ultimate breaking capacity (I cu ) as per IEC 097- (ka RMS) 0/0 Hz 0 Vac Vac 0 Vac 0 0 0 Service breaking capacity (I cs ) (%I cu ) 7% 7% 7% 7% Trip Units 0 0 0 0 0 0 0 0 0 0 Magnetic setting Dimensions B curve C curve D curve Between. and.8 times ampere rating (between. and.8 for dc) Between 7 and times ampere rating (between 7 and for dc) Between and times ampere rating (no dc rating for D curve) Dimensions (in./mm) Width Height Depth 0.7/8.9/8.00/7./.9/8.00/7./.9/8.00/7.8/7.9/8.00/7.0/7.9/8.00/7./.9/8.00/7.9/8.9/8.00/7./8.9/8.00/7 Weights (oz./g).8/ 7.70/0./0.0/0./80.70/0 9.0/0./70 Standards UL 77 Circuit Breaker, File #E9009 CSA C. #-M89 File # 790 IEC 097- VDE 00 CE Marked Table : Catalog Numbers for UL 77 Recognized C0N Supplementary Protectors Rating (A) B Curve C Curve D Curve -pole Modules -pole Modules -pole Modules -pole 8 Modules -pole Modules -pole Modules -pole Modules -pole 8 Modules -pole Modules -pole Modules -pole Modules -pole 8 Modules 0... MG MG70 MG70 MG MG7 MG7 MG0 MG MG7 MG MG7 MG7 MG MG7 MG7 MG9 MG7 MG7 MG00 MG7 MG7 MG MG7 MG7 MG MG8 MG MG MG MG70 MG MG7 MG8 MG7 MG MG MG MG MG7 MG8 MG MG7 MG8 MG7 MG MG MG MG7 MG0 MG MG MG77 MG78 MG79 MG0 MG0 MG0 MG7 MG7 MG8 MG9 MG7 MG MG MG MG9 MG0 MG 7 8 MG MG70 MG MG MG9 MG7 MG0 MG MG MG MG MG9 MG0 MG MG0 MG7 MG MG MG7 MG7 MG8 MG9 MG MG MG MG8 MG8 MG8 MG0 MG7 MG0 MG0 MG0 MG7 MG MG MG MG7 MG8 MG MG MG 0 MG7 MG70 MG8 MG9 MG MG7 MG MG MG7 MG7 MG8 MG9 MG MG MG MG MG7 MG MG MG0 MG7 MG MG MG7 MG7 MG8 MG9 MG8 MG8 MG8 MG07 MG7 MG08 MG09 MG MG7 MG MG MG9 MG77 MG0 MG MG MG MG7 0 MG0 MG707 MG MG77 MG0 MG7 MG MG MG77 MG MG77 MG70 MG77 MG87 MG MG77 MG MG77 MG MG77 MG8 MG MG708 MG MG78 MG MG7 MG MG7 MG78 MG MG78 MG7 MG78 MG88 MG MG78 MG7 MG78 MG MG77 MG9 0 0 0 MG MG MG709 MG MG7 MG8 MG79 MG9 MG MG MG7 MG MG7 MG8 MG9 MG8 MG9 MG79 MG0 MG MG MG79 MG7 MG7 MG7 MG79 MG7 MG89 MG90 MG9 MG MG MG79 MG MG8 MG9 MG79 MG0 MG MG MG77 MG MG0 MG MG 99-00 Schneider Electric All Rights Reserved

MULTI 9 System Catalog Section UL Rated Protection Devices UL 77 RECOGNIZED NC0H SUPPLEMENTARY PROTECTORS Overview The NC0H family of MULTI 9 UL 77 Recognized supplementary protectors is available for applications requiring higher current levels than available in the C0 family These UL 77 Listed products are intended for use as supplementary protectors to provide overcurrent protection within appliances or electrical equipment where branch circuit protection is already provided or is not required. These products are similar to the C0, except larger in size (three 0. in. [9 mm] modules or a total of.0 in. [7 mm] per pole). In many cases, the accessories for the C0 products will not function with the NC0. Separate accessories are available (see accessories in Section ). Standard Features Fast closing: Allow increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when the NC0 circuit breaker is tripped automatically Positive indication of contact disconnect. Green mechanical indication on front face of device shows that all poles are open. Suitable for reverse feeding. B curve: Overcurrent protection for sensitive equipment such as computers and electronics. The magnetic release operates between. and.8 times ampere rating. C curve: Overcurrent protection for all application types. The magnetic release operates between 7 and times ampere rating. D curve: Overcurrent protection for loads with high inrush currents such as motors and transformers. The magnetic release operates between and times ampere rating. Ground-fault protection with optional add-on VIGI module (see accessories in Section ). Table : Specifications for UL Recognized NC0H Supplementary Protectors Current rating: 80 A Package size: Three 0. in. (9 mm) modules;.0 in. (7 mm) width per pole Voltage (nominal): 0, 80Y/77; up to Vdc High voltage withstand: kv Connection, box lug: 0 A: #8 # AWG ( mm ) cables; torque lb-in. (. N m) 0 80 A: #8 # AWG ( 0 mm ) cables; torque 9 lb-in. (. N m) Connection: Use with copper wire only Mounting: mm DIN rail Degree of protection: Case: IP0 as per IEC 9 Terminals: IP0 Time/Current curves: C and D curves Temperature: Calibration: 77 F ( C) Operation: to 0 F (- to 0 C) Storage: -0 to F (-0 to 0 C) Tropicalization: Treatment relative humidity: 9% at F ( C) as per IEC8--0 Number of operating cycles (O C): 0,000 See selection table for weights and interrupting ratings Standards UL 77 Circuit Breaker File #E9009, CSA C. No. -M89 file #790, IEC 097-, VDE 00, CE Marked. Table : Catalog Numbers for UL 77 Recognized NC0H Supplementary Protectors B Curve C Curve D Curve Rating (A) -pole Modules -pole Modules -pole 9 Modules -pole Modules -pole Modules -pole Modules -pole 9 Modules -pole Modules -pole Modules -pole Modules -pole 9 Modules -pole Modules 0 MG7 MG8 MG7 MG7 MG7 MG87 MG77 MG78 MG777 MG88 MG778 MG779 MG788 MG789 MG790 MG7 MG8 MG7 MG7 MG7 MG87 MG7 MG7 MG7 MG89 MG7 MG77 MG7 MG77 MG78 0 MG77 MG87 MG78 MG88 MG79 MG87 MG770 MG87 MG780 MG887 MG78 MG888 MG79 MG79 MG7 MG8 MG77 MG8 MG77 MG877 MG78 MG878 MG78 MG89 MG79 MG89 MG79 MG770 0 0 0 MG79 MG70 MG89 MG7 MG77 MG77 MG87 MG77 MG78 MG78 MG889 MG78 MG79 MG79 MG79 MG78 MG79 MG70 MG77 80 MG7 MG77 MG78 MG797 MG7 MG77 MG78 MG79 99-00 Schneider Electric All Rights Reserved

Section IEC 097- Rated Protection Devices SECTION IEC 097- RATED PROTECTION DEVICES The MULTI 9 System includes several families of miniature circuit protection devices that have the IEC Ratings that are applicable in many countries other than the United States. These products are summarized below and discussed in more detail in the following pages. UL Listed and UL Recognized protection devices are described in the previous Section, while accessories for both the UL and IEC Rated devices are described in Section of this catalog. Table : Selection Table for IEC Rated Miniature Circuit Breakers Ratings per IEC 097- Standards DPN-N C0N C0H C0L CH-DC NC0H, NCH Number of poles (Ø + N),,,,,,,, Rated current (A) 77 F ( C) I n 0 0. 0. 0. 0. 0. Rated current (A) F (0 C) I n 0 0 Rated voltage (V) U e 0 0 0 0 0 Ultimate breaking capacity as per IEC 097- Standard (ka RMS) Service breaking capacity Ultimate breaking capacity as per IEC 898 (ka RMS) Trip Units 0 Vac 0 0 Vac 00 Vac 0 Vac 7 Vdc 0 Vdc 7. 0 I cs (%I cu ) 0% 7% 7% 0% 0% 0% 7% 7% 0 00 Vac Vac 0 0 * 0 Magnetic setting B curve C curve D curve MA curve Z curve..8 7.. 7..8 7 Single pole breaking capacity for IT type European grounding system (insulated neutral-double fault). Table 7: Dimensions and Weights Device Size Height Width Depth Weight in. mm in. mm in. mm oz. g DPN-N -pole.9 8 0.7 8.00 7. 0 -pole.9 8 0.7 8.00 7.88 C0N -pole.9 8..00 7 7.7 0 -pole.9 8..00 7. 0 -pole.9 8.8 7.00 7. 0 -pole.9 8 0.7 8.00 7. 0 C0H -pole.9 8..00 7 8.7 0 -pole.9 8..00 7.70 0 -pole.9 8.8 7.00 7.9 80 -pole.9 8 0.7 8.00 7. 0 C0L -pole.9 8..00 7 8.7 0 -pole.9 8..00 7.70 0 -pole.9 8.8 7.00 7.9 80 CH-DC -pole.0 77 0.7 8.00 7.8 7 -pole.0 77..00 7 8.7 0 -pole.9 8 0.7 8.00 7. 80 NC0H/NCH -pole.9 8..00 7.70 0 -pole.9 8.9 8.00 7 9.0 0 -pole.9 8. 8.00 7.0 70 99-00 Schneider Electric All Rights Reserved

Section IEC 097- Rated Protection Devices DPN-N PHASE + NEUTRAL CIRCUIT BREAKERS Overview 0800 The DPN-N Phase + Neutral Current Circuit Breaker provides phase and neutral protection against short-circuit and overload. It provides protection on the phase pole, but switches both the phase and neutral. The DPN-N is available in only one version phase + neutral. The DPN-N circuit breaker is available with B or C curve characteristics and with ratings from to 0 A. 080 N N Time/Current Curves B curveprovides control and protection against overcurrents for very long cables. Magnetic trip units operate between and times ampere rating. C curveprovides control and protection against circuit overcurrents in tertiary and industrial final distribution with TT or TNS grounding systems. Magnetic trip units operate between and times ampere rating. Accessories These devices may be used in conjunction with the C0 electrical accessories, including the SD Alarm Switch, OF Auxiliary Switch, MN Undervoltage Release, and/or the MX + OF Shunt Trip and Auxiliary Switch. The VIGI residual current detector can be added to the DPN-N to provide residual current protection. This combination must be ordered as an integral product from the factory (see Section for the DPN-N residual current detector). Table 8: Specifications for IEC Rated DPN-N Phase + Neutral Circuit Breakers Package size: Two 0. in. (9 mm) modules; 0.7 in. (8 mm) width Connection: #8 AWG ( mm ) stranded cables # AWG ( mm ) solid cable (copper only) Mounting: mm DIN rail Degree of protection: Case: IP0 as per IEC 9; Terminals: IP0 Time-current trip curve: B curve and C curve Temperature: Calibration at 8 F (0 C) Storage: 0 to 7 F (-0 to 80 C) Operating: to 8 F (-0 to 70 C) Tropicalization: Treatment Relative humidity: 9% at F ( C) as per IEC8--0 Number of operating cycles: Mechanical: 0,000 (O-C) Electrical: 0,000 at -0 A,,000 at A,,000 at A,,000 at 0 A See selection table for weights and interrupting ratings Standards IEC 097- IEC 0898 Catalog Numbers Table 9: DPN-N Phase + Neutral Circuit Breaker Catalog Numbers Rating (A) 0 0 B Curve -pole + Neutral Modules 99 90 9 9 9 9 97 98 C Curve -pole + Neutral Modules 90 9 9 9 9 98 99 970 97 97 99-00 Schneider Electric All Rights Reserved

IEC RATED C0 MINIATURE CIRCUIT BREAKERS MULTI 9 System Catalog Section IEC 097- Rated Protection Devices Overview The C0 family of MULTI 9 circuit breakers meeting IEC 097- is available primarily for equipment for export from the United States to countries not requiring UL Ratings. As shown in the table below, three types of IEC Rated C0 devices are available: C0N, C0H, and C0L circuit breaker. These model numbers refer to the maximum current interrupting rating. The relative interrupting ratings per IEC 097- are listed below; for other ratings, see the table on the next page. Table 0: Ratings Overview Circuit Breaker Rating Curves C0N C0H C0L ka at Vac ka at Vac ka at Vac B, C and D B, C and D B, C, K and MA Each of these devices is available in several trip curves, as listed in the tables with catalog numbers. They include devices ranging from 0. to A. (For higher current ratings, select devices from the higher current NC0 series.) Standard Features Fast closing: Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when the C0 device is tripped automatically. Positive indication of contact disconnect. Green mechanical indication on front face of device shows that all poles are open. Suitable for reverse feeding. B curve: Overcurrent protection for sensitive equipment (computers, electronic devices, etc.): C0N/H: The magnetic operates between and times ampere rating. C curve: Overcurrent protection for all application types: C0N/H: The magnetic operates between and times ampere rating. C0L: The magnetic operates between 7 and times ampere rating. D and K curves: Overcurrent protection for loads with high inrush currents (motors, transformers): C0N/H/L: The magnetic release operates between and times ampere rating. MA curve: C0L-MA circuit breakers are designed for motor circuit protection against short circuits. These circuit breakers are equipped with magnetic-only trip units at times ampere rating. Therefore they must be combined with a suitable thermal protection device (see the coordination table at the end of this section). Specifications Table : MULTI 9 C0 Circuit Breakers with IEC 097- Rating Package size: Two 9 mm modules; 8 mm width per pole High voltage withstand: kv Connections for C0N/H/L except L-MH (box luguse with copper wire only) Ring tongue terminal is optional 0. A, #8 # AWG ( mm ) cables; torque lb-in. (.8 N m) 0 A, #8 # AWG ( mm ) cables; torque lb-in. (.0 N m) Connections for C0L-MA:. stranded # AWG ( mm ). solid # AWG ( mm ). 0 stranded # AWG ( mm ). 0 solid # AWG ( mm ) Mounting: mm DIN rail Time-current curves: B, C, D, K, and MA Degree of protection: Case: IP0 as per IEC 9 Terminals: IP0 Temperature: Calibration temperature: 8 F (0 C); C0L rated at F (0 C) Storage temperature: -0 to 7 F (-0 to 80 C) Operating temperature: - to 8 F (-0 to 70 C) Tropicalization: Treatment Relative humidity: 9% at F ( C) per IEC8--0 Number of operating cycles: Mechanical (O-C) 0,000 Electrical (O-C),000 See selection table for weights and interrupting ratings Standards IEC 097- VDE 00, CE Marked 99-00 Schneider Electric All Rights Reserved

Section IEC 097- Rated Protection Devices Table : Catalog Numbers for IEC 097- Rated C0N Miniature Circuit Breakers Rating (A) B Curve C Curve D Curve -pole -pole -pole Modules Modules Modules -pole -pole -pole -pole 8 Modules Modules Modules Modules -pole -pole 8 Modules Modules -pole Modules -pole Modules -pole 8 Modules 0. 0 0 07 07 07 07 08 08 08 097 098 099 07 9 9 97 08 09 070 7 8 9 7 7 8 9 8 8 8 08 09 00 0 07 07 07 077 087 088 089 090 0 98 99 0 0 7 8 8 9 0 0 8 9 0 7 8 0 70 7 7 7 8 8 8 88 0 0 0 0 0 0 078 079 080 08 09 09 09 09 7 0 0 0 07 8 9 0 7 7 7 77 78 89 90 9 9 0 0 07 08 08 09 09 8 9 08 09 8 9 7 8 79 80 9 9 Table : Catalog Numbers for IEC 097- Rated C0H Miniature Circuit Breakers Rating (A) B Curve C Curve D Curve -pole -pole -pole Modules Modules Modules -pole -pole -pole -pole 8 Modules Modules Modules Modules -pole -pole 8 Modules Modules -pole Modules -pole Modules -pole 8 Modules 0. 0.7 900 90 98 99 90 90 98 98 90 907 99 99 908 909 007 008 7 7 8 8 7 9 97 7 7 7 78 79 7 7 970 97 97 97 98 98 98 98 99 997 998 999 009 0 0 0 7 8 9 0 8 8 87 88 98 99 00 0 0 7 8 77 78 79 70 7 7 7 7 7 97 97 97 987 988 989 000 00 00 0 0 0 89 90 9 0 0 0 7 8 9 0 0 9 0 70 7 7 7 7 7 7 7 7 77 78 79 977 978 979 980 990 99 99 99 00 00 00 00 0 07 08 09 7 8 9 9 9 9 9 07 08 09 0 Table : Catalog Numbers for IEC 097- Rated C0L Miniature Circuit Breakers Rating (A) B Curve C Curve K Curve -pole -pole -pole Modules Modules Modules -pole -pole -pole -pole 8 Modules Modules Modules Modules -pole -pole 8 Modules Modules -pole Modules -pole Modules -pole 8 Modules 0.. 0 9 9 07 8 9 08 09 0 78 79 80 9 97 98 7 8 70 7 8 8 9 9 9 97 0 7 8 9 7 8 8 8 8 99 00 0 0 7 8 9 0 9 0 7 7 7 7 8 8 87 88 98 99 00 0 7 7 8 9 0 0 8 9 70 7 8 87 88 89 0 0 0 07 0 0 7 8 9 7 77 78 89 90 9 0 0 0 8 9 0 7 90 08 99-00 Schneider Electric All Rights Reserved

Section IEC 097- Rated Protection Devices Coordination of C0L-MA Circuit Breaker, Thermal Relay and Contactor Standard IEC 097- defines tests at various current levels with the aim of placing the switchgear in extreme conditions. According to the status of components after testing, the standard defines two types of coordination. Table : Coordination of C0L-MA Circuit Breaker, Thermal Relay and Contactor Types of Coordination Type Type Deterioration of the contactor and relay is accepted under two conditions The choice of coordination type depends on the operating parameters. It must be suitable for the user s needs and ensure optimized cost of the installation There is no risk to the operator Parts other than the contactor and relay must not be damaged Qualified maintenance service Reduced volume and cost of equipment Continuity of service not required or ensured by replacing the faulty motor bucket Welding of the contactor or starter contacts is accepted only if they can be easily separated After Type coordination tests, the functions of protection and operation can be achieved Continuity of service is vital Reduced maintenance service Specification calling for Type coordination Various thermal relay classes: Thermal relay class must be appropriate for motor starting time The magnetic release of MA devices operates at times ampere rating. These C0L-MA circuit breakers are listed in Table. Table : Catalog Numbers for IEC 097- Rated C0L Miniature Circuit Breakers Rating (A) MA Curve -pole Modules -pole Modules -pole Modules -pole 8 Modules Rating (A) MA Curve -pole Modules -pole Modules -pole Modules -pole 8 Modules... 7 8 9 7 8 9 0. 0 0 8 9 70 Table 7: Class A 0 A Tripping Times Tripping Time (sec.) at 7. I r 0 Contactors and thermal relays referenced in the table below are TELEMECANIQUE products. See Square D Digest 7 (March, 000) pages -/7 for contactors. Table 8: Voltage (Vac) Catalog Numbers for Contactors and Thermal Relays (TELEMECANIQUE) Motors Circuit Breaker Thermal Relay I e max Contactor P (kw) I (A) Type A I rm (A) I q (ka) Type I rth 0.7 0.7.. 7. 8. 8...8..8.. 0 0 C0L-MA C0L-MA C0L-MA C0L-MA C0L-MA C0L-MA C0L-MA C0L-MA... 0 0 0 0 80 0 0 00 00 0 0 LC-D09 LC-D09 LC-D8 LC-D LC-D LC-D LC-D0 LC-D0 LR D 0 LR D 07 LR D 08 LR D LR D LR D LR D LR D /../../ / /8 7/ / 0/0 I rm (A) = Magnetic release (in amperes) I q (KA) = Interrupting rating (in ka) I rth = Thermal relay current rating 99-00 Schneider Electric All Rights Reserved 7

Section IEC 097- Rated Protection Devices IEC RATED CH-DC CIRCUIT BREAKERS FOR DC CIRCUITS Overview The CH-DC circuit breakers are used in circuits with dc power supplies up to Vdc (-pole) or 7/0 Vdc (-pole). The CH-DC provides protection of circuits against short-circuit currents and overload currents, and is available with ratings from to 0 A. Additionally, it allows manual control or isolation of a dc circuit. These are typically used in applications such as emergency lighting, automatic systems, electrolysis, telephony, etc. Standard Features Fast closing: Allows increased withstand to the high inrush currents of some loads. Trip-free mechanism: Contacts cannot be held in the on position when the CH-DC is tripped automatically. Isolation with positive break indication: Green strip on the operating handle indicates that all poles are open. C curve: Overcurrent protection for all application types. Magnetic release operates between 7 and times ampere rating. Suitable for reverse feeding. Connection Accessories Box lug connections for copper wiring are provided for the CH-DC devices. Remote monitoring and control can be provided with optional NC0 electrical accessories including the OF Auxiliary Switch, SD Alarm Switch, MN Undervoltage Release, and/or MX + OF Shunt Trip. NOTE: The C0 electrical accessories are not compatible with the CH-DC circuit breaker. Standards Compliance with IEC 097- Standards Table 9: Specifications for IEC Rated CH-DC Circuit Breakers Package size: Two 9 mm modules; 8 mm width per pole Rating on connector: Copper wiring only Voltage (nominal): -pole: 7 Vdc; -pole: 7/0 Vdc Temperature: High voltage withstand: kv Calibration: F (0 C) Connection: Box lugtunnel terminals for #8 # AWG ( mm ) cables Storage: -0 to 7 F (-0 to 80 C) Mounting: mm DIN Rail Operating: - to 8 F (-0 to 70 C) Time-current curves: C curve; Magnetic releases operate Tropicalization: Treatment Relative humidity: 9% at F between 7 and I n ( C) as per IEC 8--0 Degree of protection: Number of operating cycles: Case: IP0,000 (O-C) at L/R 0.0 sec. Terminals: IP0 as per IEC 9 See selection table for weights and interrupting ratings Catalog Numbers Table 0: C CurveCH-DC Circuit Breakers Rating (A) -pole Modules 0 0 -pole Modules 0 0 080088 080089 + 0 0 0 0 or or 0 0 0 0 0 07 08 09 00 0 07 08 09 00 -pole Line Side Feeding + Load Side Feeding -pole Line Side Feeding + Load Side Feeding 8 99-00 Schneider Electric All Rights Reserved

Section IEC 097- Rated Protection Devices IEC RATED NC0H CIRCUIT BREAKERS Overview 080090 -pole The NC0H family of MULTI 9 circuit breakers meeting IEC 097- is available primarily for OEMs wishing to export manufactured products to countries requiring IEC Ratings instead of UL Ratings. They are suitable for protection of cables against overloads and short circuits in equipment. They can also be used for manual control and isolation of circuits. The NC0H circuit breakers are available in B, C, and D trip curves, as listed in the tables with catalog numbers. They include devices ranging from to A. (For lower current ratings, select devices from the C0 series.) Figure : IEC 097- Rated NC0H Circuit Breakers -pole -pole -pole 08009 08009 08009 Standard Features Fast closing: Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in ON position when NC0 is tripped automatically. Isolation with positive break indication: Green strip on operating handle indicates all poles are open Terminals ensure pull-out withstand of cables, guiding of cables into correct position, and tightening of wide cross-section cables. B curve: Overcurrent protection of very long cables and protection of networks supplied by generators. The magnetic release operates between and times ampere rating. C curve: Overcurrent protection for all application types. Magnet release operates between 7 and times ampere rating. The magnetic release operates between 7 and times ampere rating. D curve: Overcurrent protection for loads with high inrush currents (motors, transformers). The magnetic release operates between and times ampere rating. Suitable for reverse feeding. Accessories Ground-fault protection can be provided when combined with a VIGI NC0 module. Remote tripping and indication can be provided by adding a variety of auxiliaries (see section for accessories). NOTE: The C0 accessories may not match the NC0 circuit breaker. Specifications Table : Specifications for IEC Rated NC-0H Circuit Breakers Package size: Three 9 mm modules; 7 mm width per pole High voltage withstand: kv Maximum voltage rating: 0 Vac Connection: Box lug: 0 A: #8 to # AWG ( 0 mm ) cables Use with copper wire only Mounting: mm DIN rail Degree of protection: Case: IP0 as per IEC 09 Terminals: IP0 Time/Current curves: B, C and D curves Temperature: Calibration: 8 F (0 C) Storage: -0 to 7 F (-0 to 80 C) Operating: - to 8 F (-0 to 70 C) Tropicalization: Treatment (relative humidity: 9% at F ( C) as per IEC8--0 Number of operating cycles: 00 (O-C) at A 000 (O-C) at 80 A See selection table for weights and interrupting ratings Standards IEC 097- VDE 00 CE Marked 99-00 Schneider Electric All Rights Reserved 9

Section IEC 097- Rated Protection Devices Table : B CurveNC0H and NCH Circuit Breakers Rating (A) -Pole Modules -Pole Modules -Pole 9 Modules -Pole Modules Rating (A) -Pole Modules -Pole Modules -Pole 9 Modules -Pole Modules 70 7 7 7 0 707 78 79 70 70 7 7 7 708 79 70 7 0 70 7 7 7 80 709 70 7 7 70 7 7 77 0 7 7 7 7 70 7 77 78 7 7 7 7 0 70 77 78 79 Table : C CurveNC0H and NCH Circuit Breakers Rating (A) -Pole Modules -Pole Modules -Pole 9 Modules -Pole Modules Rating (A) -Pole Modules -Pole Modules -Pole 9 Modules -Pole Modules 7 7 77 778 0 7 7 77 78 7 77 78 779 7 7 77 78 0 77 78 79 780 80 7 7 77 78 78 79 770 78 0 7 7 77 787 79 70 77 78 7 7 777 788 0 70 7 77 78 Table : D CurveNC0H and NCH Circuit Breakers Rating (A) -Pole Modules -Pole Modules -Pole 9 Modules -Pole Modules Rating (A) -Pole Modules -Pole Modules -Pole 9 Modules -Pole Modules 789 700 7 7 0 79 70 7 77 790 70 7 7 0 79 70 77 78 0 79 70 7 7 79 707 78 79 79 70 7 7 80 797 708 79 70 79 70 7 7 0 798 709 70 7 Table : C CurveNC0LS Circuit Breakers Rating (A) -Pole Modules -Pole Modules -Pole 9 Modules -Pole Modules Rating (A) -Pole Modules -Pole Modules -Pole 9 Modules -Pole Modules 777 788 799 7 78 79 70 7 778 789 700 7 0 78 79 70 7 0 779 790 70 7 0 78 79 70 7 780 79 70 7 78 79 70 77 Table : D CurveNC0LS Circuit Breakers Rating (A) -Pole Modules -Pole Modules -Pole 9 Modules -Pole Modules Rating (A) -Pole Modules -Pole Modules -Pole 9 Modules -Pole Modules 7 7 7 7 7 7 77 78 7 7 7 7 0 7 77 78 79 0 7 7 7 7 0 77 78 79 70 7 7 7 77 78 79 70 7 Table 7: C CurveNC0LH Circuit Breakers Rating (A) -Pole Modules -Pole Modules -Pole 9 Modules -Pole Modules Rating (A) -Pole Modules -Pole Modules -Pole 9 Modules -Pole Modules 709 70 7 7 7 7 7 7 7 7 7 7 0 7 7 7 77 0 7 7 7 7 0 7 7 77 78 7 7 7 7 7 77 78 79 0 99-00 Schneider Electric All Rights Reserved

Section IEC Rated Ground-fault Protection Devices SECTION IEC RATED GROUND-FAULT PROTECTION DEVICES SELECTION TABLE The MULTI 9 System includes four products that provide ground-fault protection per IEC Standards. These products are summarized below and discussed in more detail in the following pages. Table 8: Selection Table for IEC Rated Ground-fault Protection Devices Ratings ID RCD C0 VIGI NC0 VIGI DPN-N VIGI Number of poles -pole -pole -pole -pole -pole -pole -pole -pole -pole Ø + N Rated current (A) 77 F ( C) I n 0 0 < < < < 0 Sensitivities (ma) Instantaneous Selective 0 00 00 00 s 00 s Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 00 s Yes Yes Yes Yes Yes Yes Voltage (nominal) 0 Vac 0 0 Vac, 0 Vac 0 Vac 0/00 Vac Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Trip Units B curve Yes Time/Current curve C curve N/A Depends on circuit breaker used Depends on circuit breaker used Yes D curve Dimensions (in./mm) Width./.8/7./././.8/7./.9/8./8./ Height.9/8.9/8.9/8.9/8.9/8.9/8.9/8.9/8.9/8.9/8 Depth.00/7.00/7.00/7.00/7.00/7.00/7.00/7.00/7.00/7.00/7 Weight (oz./g) 7.70/0.9/0./0.9/0 < =./80 > = 7./.8/0 9.7/0.0/70.70/90 s Selective = time delay Table 9: IEC Rated Ground-fault Protection Devices 080 080 080 080 -pole C0 VIGI Module -pole NC0 VIGI Module DPN-N VIGI Module ID RCD 99-00 Schneider Electric All Rights Reserved

Section IEC Rated Ground-fault Protection Devices IEC RATED ID RESIDUAL CURRENT SWITCHES Overview The ID Residual Current Switches provide earth leakage protection for electrical circuits, as well as the functions of isolation and switching. ID switches have an electromechanical release that operates without any auxiliary source of supply to open a circuit automatically in the case of an earth leakage or fault between phase and earth greater than, 0, or 00 ma, depending on the model. A version with time delay (selective) provides additional time discrimination with downstream instantaneous residual current devices. The ID Switch is available in -pole (-phase) and -pole (-phase) versions only. The ground fault is displayed on the front face by a red mechanical indicator. NOTE: The ID residual current switch has only one protective functiondetection of earth leakage current. There is no thermal or magnetic overcurrent protection. Therefore, the circuit must be protected by an upstream circuit breaker or supplementary protector. For combined overcurrent and residual current protection, an alternative is a C0 circuit breaker equipped with an auxiliary VIGI ground-fault detector module. The ID device can also be manually operated as a switch. Remote monitoring and control can be provided with optional C0 accessories including the OF Auxiliary Switch, SD Alarm Switch, MN Undervoltage Release, and/or MX + OF Shunt Trip. NOTE: All of these auxiliaries require the use of the OFS Auxiliary Switch (Cat. No. 9) to adapt to the ID Residual Current Switch. Test button: A test button located on the front of the ID Residual Current Switch is provided to allow periodic testing of the device. Table 0: IEC Rated ID Residual Current Switches -pole ID Residual Current Switch -pole ID Residual Current Switch 0800 N 0807 N T R T R N N Specifications Table : Specifications for IEC Rated ID Residual Current Switches Package size: See Table 8 Voltage (nominal): 0 to Vac, +%, -0%, 0/0 Hz High voltage withstand: kv Connection, box lug: (copper wire only) # AWG ( mm ) stranded cables # AWG (0 mm ) solid cables Sensitivities: Fixed at, 0, or 00 Time/current curve: Instantaneous or selective release S (time delay) Level of immunity: 0 A peak, according to 8/0 ms periodical wave Operating temperature: to 0 F (- to 0 C) Tropicalization: Treatment Relative humidity: 9% at F ( C) per IEC8--0 Mounting: mm DIN rail Number of operating cycles (O-C): Electrical: 0,000 See selection table for weights and interrupting ratings Standards IEC 08 EN -008 CE Marked 99-00 Schneider Electric All Rights Reserved

Catalog Numbers Table : MULTI 9 System Catalog Section IEC Rated Ground-fault Protection Devices Catalog Numbers for ID Residual Current SwitchesAC Class Rating (A) Sensitivity (ma) -pole (0 Vac) Modules -pole ( Vac) 8 Modules 00 0 0 0 0 0 0 08 8 00 s 08 80 0 00 s 0 0 00 0 00 s 0 09 s Selective = time delay Figure : Possible Device Combinations OF Auxiliary Switch and/or SD Alarm Switch MX Shunt Trip and/or MN Undervoltage Release OFS Auxiliary Switch ID Residual Current Switch 0800 080new 080new 080new + + + NOTE: Availability of UL Listed products to be announced. 99-00 Schneider Electric All Rights Reserved

Section IEC Rated Ground-fault Protection Devices IEC RATED C0 VIGI MODULES FOR GROUND-FAULT PROTECTION Overview 0808 Vigi Module The C0 VIGI residual current detector can be added to the C0 circuit breaker to provide a high level of protection against earth leakage faults. The VIGI module clips onto the right-hand side of a C0 protective device and is mechanically linked to the C0 circuit breaker, which it trips when the VIGI detects residual current. The VIGI module combines a current sensing toroid and residual current relay in one case and operates without an auxiliary power supply source. It may be ordered with a variety of non-adjustable sensitivities ( to,000 ma). A version with time delay (selective) provides additional time discrimination with downstream instantaneous residual current devices. A built-in filtering device minimizes nuisance tripping due to transient voltages (lightning, line disturbances, etc.) and transient currents (from high capacitive circuits). VIGI modules are available for use with -, -, and -pole C0 circuit breakers. The VIGI module may be field installed. A visual indicator of the ground fault is provided by a red flag on the VIGI operating handle. A manual test button on the front panel allows manual testing of the VIGI module. The C0 VIGI module can be field-adapted to reset in one of two modes: Automatic reset when the associated protective device handle is reset, or by manually resetting the VIGI prior to reclosing the supplementary protector. A version with time delay (selective) provides additional time discrimination with downstream instantaneous residual current devices. NOTE: The C0 version of the VIGI Module cannot be used with the NC0 series. A different series of VIGI Modules is available for the NC0 devices. Figure : Example of Residual Current Circuit Breaker 0809 0800 080 + = C0 Circuit Breaker Vigi Module Residual Current Circuit Breaker NOTE: Also see the DPN-N Residual Current Circuit Breakers and ID Residual Current Switches in this catalog. Accessories Terminal screw shields prevent contact with the VIGI module terminal screws. The bag includes twenty pieces of single-pole shields. (Cat. No. 98). Specifications Table : Specifications for IEC Rated VIGI Modules for Ground-fault Protection Package size: See Selection Table 8 Voltage (nominal): 0 0 Vac, +% -0%, 0/0 Hz; 0 Vac, +% -0%, 0/0 Hz High voltage withstand: kv Connection: Box lug: (copper wire only) Cables: stranded # AWG ( mm ), solid # AWG ( mm ), stranded # AWG ( mm ), solid # AWG ( mm ) Mounting:.8 in. ( mm) DIN rail Time-current curves: Depends on circuit breaker Time/current curve: Instantaneous or selective release s Sensitivities: Fixed at, 0, 00, or 00 Temperatures: Calibration: 77 F ( C). Operating: to 0 F (- to 0 C) See selection table for weights and interrupting ratings 99-00 Schneider Electric All Rights Reserved

Section IEC Rated Ground-fault Protection Devices Standards Combined with C0, the VIGI module forms a residual current device which conforms to the following standards: IEC 09 EN 09 Catalog Numbers Table : Catalog Numbers for VIGI C0 ModulesAC Class Rating (A) Voltage (Vac) Sensitivity (ma) -pole Modules -pole -pole -pole Modules 7 Modules 7 Modules 0 0 80 8 0 0 00 s 00 s 8 0 8 0 Width of one module = 0. in. (9 mm). s Selective = time delay Figure 7: IEC Rated C0 VIGI Modules 080 -Pole -Pole -Pole 7 T T T 8 99-00 Schneider Electric All Rights Reserved

Section IEC Rated Ground-fault Protection Devices IEC RATED NC0 VIGI RESIDUAL CURRENT CIRCUIT BREAKERS Introduction 080 -pole NC0 Vigi Module The NC0 VIGI residual current detector can be added to the NC0 circuit breaker to provide a high level of protection against earth leakage faults. The VIGI module clips onto the right-hand side of a NC0 protective device and is mechanically linked to the NC0 circuit breaker, which it trips when the VIGI detects residual current. The VIGI module combines a current sensing toroid and residual current relay in one case and operates without an auxiliary power supply source. It may be ordered with a variety of non-adjustable sensitivities (0 to,000 ma). A version with time delay (selective) provides additional time discrimination with downstream instantaneous residual current devices. VIGI modules complete the NC0 -, - and -pole circuit breakers to provide: Protection of people against indirect contact (per IEC Standards) Additional protection of people against direct contact (0 ma) Protection of electrical installations against insulation faults Table : Specifications for IEC Rated NC0 VIGI Residual Current Circuit Breaker The NC0 circuit breaker and VIGI module combination is protected against nuisance tripping due to transient overvoltages such as lightning, switching on the network, etc. Connections: Stranded: 0 A # AWG mm Solid: 0 A # AWG 0 mm Current rating: 0 A Voltage: 0 Vac, +%, -0%, 0/0 Hz The ac class VIGI module guarantees tripping for sinusoidal ac residual currents, either suddenly applied or slowly increasing Total vertical discrimination with the I n 00 ma to A s selective sensitivities if it is installed: Upstream from an instantaneous residual current device Downstream from an index II, time-delayed residual current device, where in both cases the I n of the downstream device I n/ of the upstream device Resetting the NC0 circuit breaker and VIGI module combination in a single operation by resetting the circuit breaker Mechanical indication of the ground-fault is shown on the front face of the VIGI module with a red indicator Instantaneous or selective tripping: Fixed sensitivities for all ratings See selection table for weights and interrupting ratings Standards Complies with IEC 09 Standard Table : Catalog Numbers for NC0 VIGI ModuleAC Class Rating (A) Voltage (Vac) Sensitivity (ma) -pole 7 Modules -pole -pole Modules Modules 0 788 78 78 0 0 00 s 78 78 780 00 s 78 78 78 Width of one module = 0. in. (9 mm). s Selective = time delay Figure 8: IEC Rated NC0 VIGI Modules 080 080 0807 -pole NC0 Vigi Module -pole NC0 Vigi Module -pole NC0 Vigi Module 080 T 08080 T 0808 7 T 8 99-00 Schneider Electric All Rights Reserved

DPN-N VIGI RESIDUAL CURRENT CIRCUIT BREAKERS MULTI 9 System Catalog Section IEC Rated Ground-fault Protection Devices Overview The DPN-N VIGI Residual Current Circuit Breaker protects against short-circuit and overload as well as earth leakage faults, in one device. It provides overcurrent protection on the phase pole, but switches both the phase and neutral. The DPN-N is available in only one version: with one phase and neutral. This combination must be ordered as an integral product from the factory. B curveprovides control and protection against overcurrents for very long cables. Magnetic trip units operate between and I n. C curveprovides control and protection against circuit overcurrents in tertiary and industrial final distribution with TT or TNS grounding systems. Magnetic trip units operate between and I n. DPN-N VIGI Residual Current Circuit Breaker 080 N N Accessories These devices may be used in conjunction with the C0 electrical accessories, including the SD Alarm Switch, OF Auxiliary Switch, MN Undervoltage Release, and/or the MX + OF Shunt Trip and Auxiliary Switch. Specifications Table 7: Specifications for IEC Rated DPN-N VIGI Residual Current Circuit Breakers Package size: Four 0. in. (9 mm) modules;. in. ( mm) width Connection: #8 AWG ( mm ) stranded cable # AWG ( mm ) solid cable (copper only) Time-current trip curve: B curve and C curve Operating temperature: to 0 F (- to 0 C) Tropicalization: Treatment Relative humidity: 9% at F ( C) as per IEC8--0 Calibration at 8 F (0 C) Degree of protection: Case: IP0 as per IEC 9; Terminals: IP0 Mounting:.8 in. ( mm) DIN rail Number of operating cycles: Mechanical: 0,000 (O-C) Electrical:,000 (O-C) at A See selection table for weights and interrupting ratings Standards IEC 097-, IEC 0898 and IEC 09 CE Marked Catalog Numbers Table 8: Rating (A) 0 0 DPN-N VIGI Residual Current Circuit Breaker -pole + N (B Curve) Modules -pole + N (C Curve) Modules 0 ma 00 ma 0 ma 00 ma 90 9 9 9 9 97 98 99 970 97 97 97 97 977 978 979 9 9 9 9 97 98 99 98 98 98 98 987 988 989 99-00 Schneider Electric All Rights Reserved 7

Section IEC Rated Ground-fault Protection Devices 8 99-00 Schneider Electric All Rights Reserved

Section Accessories SECTION ACCESSORIES OVERVIEW The MULTI 9 System includes an extensive line of field-installable accessories that enables the system to be used in many applications. Electrical auxiliaries include shunt trip, undervoltage release, auxiliary switch, and alarm switch. Control and display devices include push buttons, motor operators, and signal lamps. Also available is a variety of accessories for locking, operating, shielding, mounting, etc. Other devices include switches and timers. The following diagram shows many of the accessories. NOTE: In many cases, the NC0 series of devices do not use the same accessories as the C0 series. All of the accessories described in this section may be field-installed. These include electrical auxiliaries, comb bus bars, mounting devices, shielding and identification systems, operators, and display, status, and control devices. Figure 9: Overview of MULTI 9 System Accessories. DC Circuit Breaker (UL 89A). C0N UL 77 Recognized Supplementary Protectors or UL 89 Listed Circuit Breakers. Undervoltage Release (MN). Shunt Trip (MX + OF). Auxiliary Switch (OF). Alarm Switch (SD) 7. Comb Bus Bar 8. Connector (availability pending) 9. Ring Tongue Terminal Kit. Motor Operator C0N. C0N/NC0 Vigi Module. Terminal Cover. Interphase Barrier. Terminal Screw Shield. Padlock Attachment (Off Position). Plug-in Base 7 Rotary Handle 8. Spacer 9. Identification System A 8 7 9 O-OFF A 080 O-OFF O-OFF T or D D D D D D D D D D D D D D D D D D 7 8 9 99-00 Schneider Electric All Rights Reserved 9

Section Accessories ELECTRICAL AUXILIARIES Overview The MULTI 9 product line includes a variety of electrical auxiliaries for the C0 and NC0 supplementary protectors and circuit breakers. They may be attached to the protective device as needed to fulfill the tripping or monitoring application requirements. They include the following devices. MN Undervoltage Release MX + OF Shunt Trip and Auxiliary Switch OF Auxiliary Switch SD Alarm Switch TM Motor Operator NOTE: The MULTI 9 VIGI Module, which adds ground-fault protection, is described in Section. As shown in the figure below, these are mechanically linked to the base C0 or NC0 protective devices. Figure 0: Possible Auxiliary Combinations 08007 08007 08007 08007 0809 SD Alarm Switch 0808 OF Auxiliary Switch MX + OF Shunt Trip and Auxiliary Switch 0800 U> 080 MN Undervoltage Release D u > L or + C0 Supplementary Protector or Circuit Breaker 9 9 Fault Normal 9 L or + N or Closed Open L or + N or C Closed Open C L or + N or D N or MN Undervoltage Release The MN Undervoltage Release is used to provide remote tripping of C0 or NC0 devices. It causes the device to trip whenever the MN detects a drop of its control voltage to the range of 70 to % of nominal. The tripped condition is shown by a red indicator flag on the front panel of the MN undervoltage release. The MN undervoltage release is mechanically linked to the C0 or NC0 device. It may be used in conjunction with the SD Alarm Switch, OF Auxiliary Switch, and/or the MX + OF Shunt Trip and Auxiliary Switch. NOTE: The tripped circuit breaker or supplementary protector must be manually reset. The MN Undervoltage Trip prevents the device from being reclosed until the control voltage has been restored. Models must be selected depending on the level of control voltage source (ac or dc). Used for emergency stop via push button. Used as safety feature on circuit supplying several machines, to prevent uncontrolled restarting of motors. UL Recognized for use with UL 77 Recognized devices and UL Listed for use with UL 89 Listed devices. CSA and IEC Rated The linkage is mechanical, thus ensuring the integrity of the protection function. Multiple auxiliaries may be used in combination with a single C0 protective device. Terminal pads for connection of control wiring are provided for either two # AWG (. mm ) cables, or one # AWG (. mm ) cable. 0 99-00 Schneider Electric All Rights Reserved

Section Accessories MN s Timedelayed Undervoltage Release The time-delayed undervoltage release is identical to the standard MN undervoltage release, except that it allows brief interruptions of control power without opening the circuit breaker due to undervoltage. It allows a 0. second time delay before opening the associated protective device. Table 9: Power Consumption of MX and MN Accessories Type Voltage VA or W MX (inrush) MN (holding) s MN (holding) IEC Rated; not UL Recognized Vac 0 0 0 Vac 0 8 0 Vac 00 0 Vdc 8 Vac/Vdc Vac/Vdc 0 0 0 Vac. 8 Vac. 8 Vdc.0 0 0 Vac. MX + OF Shunt Trip and Auxiliary Switch OF Auxiliary Switch The MX + OF switch combines the functions of shunt trip and auxiliary switch into one device. The MX Shunt Trip, when energized by a control voltage, provides remote tripping of the associated C0 circuit breaker or supplementary protector to which it is mechanically linked. The tripped condition is indicated by a red indicator flag on the front panel of the MX + OF. The protective device must be manually reset after being tripped by the MX. NOTE: When the OF function is combined with the MX Shunt Trip, no test button is provided. The MX + OF Switch may be used in conjunction with the SD Alarm Switch, which presents the trip status, and/or the MN Undervoltage Release. UL Recognized for use with UL 77 Recognized devices and UL Listed for use with UL 89 Listed devices. CSA and IEC Rated. The OF Auxiliary Switch communicates the OPEN or CLOSED status of the associated C0 circuit breaker or supplementary protector via auxiliary contacts. It is mechanically linked to the supplementary protector (See the SD Alarm Switch for TRIP status). It may be used in conjunction with the SD Alarm Switch, which presents the trip status, and the MN Undervoltage Release. It would not normally be used with the MX + OF Shunt Trip because that device already includes the OF function. UL Recognized for use with UL 77 Recognized devices and UL Listed for use with UL 89 Listed devices. CSA and IEC Rated. 99-00 Schneider Electric All Rights Reserved

Section Accessories SD Alarm Switch The SD Alarm Switch communicates the TRIP status of the associated C0 or NC0 circuit breakers or supplemental protectors via auxiliary contacts. It is mechanically linked to the protective device. (Use the OF Auxiliary Switch for OPEN or CLOSED status.) Voltage Breaking Capacity (A) SD OF 77 Vac < 0 Vac 0 Vac < 8 Vdc < Vdc Locally, it also indicates the TRIPPED-ON-FAULT condition of the protective device with a red indicator flag on the front panel. A test switch allows simulation of the SD function without operating the protective device. The SD Alarm Switch is reset when the associated protective device is reset, or it may by reset independently of the protective device with a reset lever on its front panel. The SD Alarm Switch may show the circuit breaker status, using V Type Signal Lamps, other annunciators, or a control system. It may be used in conjunction with the OF Auxiliary Switch which presents the OPEN or CLOSED status, the MN Undervoltage Release, and/or the MX + OF Shunt Trip. UL Recognized for use with UL 77 Recognized devices and UL Listed for use with UL 89 Listed devices. CSA and IEC Rated Table 0: Catalog Numbers for Electrical Auxiliaries Device Control Voltage C0 NC0 Width in Modules Vac Vdc UL/IEC IEC UL/IEC IEC MX + OF shunt trip MN undervoltage release Instantaneous 8 8 0 0 0 77 0 77 0 0 8 0 0 0 0 0 0 0 77 8 8 0 0 0 0 0 8 MG97 MG97 MG97 MG9 MG97 MG9 MG98 MG9 98 97 9 9 90 9 MG70 MG79 MG78 MG7 MG7 78 77 7 70 70 Time delayed 0 0 9 0 0 0 0 7 OF auxiliary switch MG9 9 MG7 7 SD alarm switch MG98 97 MG7 7 Figure : Electrical Auxiliary Schematics MX + OF Shunt Trip MN Undervoltage Release OF Auxiliary Switch SD Alarm Switch 080new U > U < C C D D 9 9 9 99-00 Schneider Electric All Rights Reserved

Section Accessories TM Motor Operator The TM Motor Operator modules allow remote operation of C0 circuit breakers and supplementary protectors. The TM is mechanically linked to the protective device via its handle. This handle can also be used to manually operate the TM and its associated protective device. The presence of a control voltage in the TM causes the closing of the circuit breaker poles; when this voltage is interrupted, the poles open. A red indicator is displayed when the TM Motor Operator is energized or being opened; the indicator is gray when it is not energized or is completely opened. - or -pole A selector switch on the TM front panel is used to disconnect the motor operator or place it in the AUTO (operational) mode. The open position frees an integral padlocking device to allow physical lockout. (Required 0.8 in. [7 mm] dia. padlock, not included.) NOTE: Reclosing after a fault should primarily be carried out locally and in manual mode after verification and clearance of the fault. The use of an SD Alarm Switch, wired in series with the control line of the TM Motor Operator, prevents automatic and remote reclosing. - or -pole NOTE: The C0 protective device may be manually operated via its handle, even with the TM installed. The TM Motor Operator may also be used in conjunction with the OF Auxiliary Switch to give the OPEN or CLOSED status of the protective device. IEC Rated; not UL Recognized Auto Table : IEC Rated C0 TM Motor Operators 080 ON OFF s s t(s) Closing Times Description US No. IEC No TM Remote motor control for C0 -pole or -pole TM Remote motor control for C0 -pole or -pole Table : MG8 8 MG8 8 Specifications for IEC Rated C0 TM Motor Operators Voltage: 0 Vac (-%, +%) Frequency: 0/0 Hz Response to undervoltage: Mechanical opening of poles (>0. sec.) Reclosing two seconds after power is restored Insensitive to short-supply interruptions (<0. sec.) Opening time of associated circuit breaker: 0. sec. by TM motor operator 0.0 sec. by shunt trip or undervoltage release Rate of operation: seconds max. up to operations per day Width: 7 modules:. in. ( mm) Closing time: Two seconds Power consumption: Inrush 8 VA Holding VA Status indication: Mechanical indicator flag Number of operating cycles (O-C): 0,000 for TM motor operator/c0 circuit breaker combination at F (0 C) Terminals: Tunnel terminals are suitable for # AWG ( mm ) cables Figure : IEC Rated TM Motor Operator Schematics 0800 A L 0800 A C0 -pole and -pole 0800 A C0 -pole and -pole M SD Auto SD Auto A OF 0 V OF 0 V N A A 99-00 Schneider Electric All Rights Reserved

Section Accessories COMB BUS BARS UL Recognized C0 Comb Bus Bars A Comb Bus Bar can be used to provide common service to a number of MULTI 9 supplementary protectors and accessories. This eliminates the hassle of providing discrete wiring to a number of protective devices operating from one power source. It is available in 0.7 in. (8 mm) pole spacings for the C0 series. It meets the UL 77 requirements. These are available in -, -, or -phase (conductor) models, and can be purchased in -pole lengths. Field wiring may be applied directly to the comb bus bar by inserting both the conductor and the tooth of the comb into the same box lug connector of the C0N supplementary protector Figure : UL Recognized C0 -phase Comb Bus Bar Refer also to the connector and tooth cap accessories for the comb bus bar. Rated insulation voltage: 80Y/77 Vac Rated current: A service single-feed Available in -, -, or -phases (conductors) Distance between outgoing poles: 0.7 in. (8 mm) Lengths: Fixed length of poles (Consult Square D field office for other sizes.) Height: 0.80 inches (0 mm) above circuit breaker Connection: Comb tooth and main feed wire (# AWG to # AWG) connect to box lug of UL 77 C0N supplementary protector UL Recognized (for use with UL 77 devices only; not CSA Rated) Table : Catalog Numbers for UL Recognized C0 Comb Bus Bars Description Length Type Cat. No. -pole comb bus bar 8. in. ( mm) -phase -phase -phase MG8 MG8 MG87 Tooth Caps for UL Recognized Comb Bus Bars Tooth Caps for UL Recognized Comb Bus Bars may be slipped onto the unused teeth of the Comb Bus Bar. They come in strips of five with -pole spacing, but can be snapped apart to be used individually. 080 Table : Description Tooth Caps for UL Recognized Comb Bus Bars Cat. No. Tooth caps for 0.7 in. (8 mm) comb bus bar (0 pieces) 088 99-00 Schneider Electric All Rights Reserved

Section Accessories IEC Rated C0 Comb Bus Bars These are available in -, -, - or -phase (conductor) models, and can be purchased in -pole, - pole, or -pole ( meter) lengths. Refer also to the accessories for the Comb Bus Bar described below. Rated insulation voltage: 00 Vac as per IEC. Rated Current: 0 A service single-feed, 0 A double-feed Available in -, -, -, or -phases (conductors) Distance between outgoing poles: 8 mm (0.7 in.) Lengths:,, or -poles; may be cut to desired length IEC Rated Figure : IEC Rated C0 Comb Bus Bars and End Caps -phase -phase -phase -phase Table : Catalog Numbers for IEC Rated C0 Comb Bus Bars Description Length Type Cat. No. -pole comb bus bar -pole comb bus bar (package of ) 8. in. ( mm) 7 in. ( mm) -pole comb bus bar 9. in. ( m) -phase -phase -phase -phase -phase -phase -phase -phase -phase -phase -phase -phase 88 88 88 88 89 89 89 89 80 80 80 80 End Caps for IEC Rated C0 Comb Bus Bars The End Caps are insulating devices which snap onto the ends of the Comb Bus Bar to retain the bus bars within their protective shield and to ensure the spacing of the conductors. IEC Rated Table : End Caps for IEC Rated C0 Comb Bus Bars Description Type Cat. No. End caps for comb bus bar (0 pieces) -phase/-phase 88 -phase/-phase 887 99-00 Schneider Electric All Rights Reserved

Section Accessories Connector for IEC Rated Comb Bus Bars The IEC Rated connectors are provided for connecting field wiring to a comb bus bar. These connectors accept up to # AWG wiring. IEC Rated Torque: lb-in (. N m) Table : IEC Rated C0 Connectors Description Wire Size Cat. No. Connector ( pieces) # AWG ( mm ) 88 Tooth Caps for IEC Rated Comb Bus Bars Tooth Caps for IEC Rated Comb Bus Bars are insulated protectors which may be slipped onto the unused teeth of the Comb Bus Bar. Tooth caps come in strips of five with -pole spacing, but can be snapped apart to be used individually. Table : Tooth Caps for IEC Rated Comb Bus Bars Description Tooth caps for comb bus bar (0 pieces) Cat. No. 888 DEVICE SHIELDING DIN Rail Spacer The Spacer clips onto a DIN rail to occupy the space of one 0. in. (9 mm) module. It can be used to provide space for future protective devices and accessories. It may also be used to provide a ventilation gap to prevent overheating. IEC Rated; not UL Recognized Table 7: IEC Rated DIN Rail Spacer Description Width US No. IEC No. Spacer for IEC Rated C0 and NC0 circuit breakers 0. in. (9 mm) MG70 70 Interphase Barriers The Interphase Barriers snap onto the top and bottom of the C0 devices to provide increased isolation distance between two adjacent connectors. NOTE: These are not needed with the versions of C0 with UL 89 Rating nor with the Ring Lug Terminal kit, since those products already include increased isolation barriers. IEC Rated; not UL Recognized Table 8: IEC Rated Interphase Barrier Description Quantity US No. IEC No. Interphase barriers for C0 circuit breakers pieces MG700 700 99-00 Schneider Electric All Rights Reserved

Section Accessories Terminal Screw Shields The Terminal Screw Shield snaps onto the front of the C0N or NC0 protective devices to provide greater insulation of the terminal screws. IEC Rated; not UL Recognized Table 9: IEC Rated Terminal Screw Shields Description Device Quantity Cat. No. Terminal screw shield C0 Bag of strips of 98 NC0 Bag of strips of 7 Terminal Covers The Terminal Covers completely cover the terminals, either standard or screw-type connectors. They make the use of the interphase barriers unnecessary (and impossible). IEC Rated; not UL 77 Recognized Table 0: UL Recognized and IEC Rated Terminal Covers Description Device Size US No. IEC No. -pole MG97 97 Terminal cover C0 -pole -pole -pole MG97 MG97 + MG97 MG978 97 97 + 97 978 Terminal cover NC0 -pole -pole -pole -pole MG97 MG97 MG97 + MG97 MG978 97 97 97 + 97 978 Ring Lug Terminal Kit 0807 The Ring Lug Terminal kit provides isolation barriers and ring terminals to convert a standard box lug UL 77 Recognized C0 supplementary protector to allow front or rear connection with ring type terminals. The kit allows a UL 77 Recognized C0N device to retain its rating. It cannot be fieldinstalled on a UL 89 Listed C0 product. These are user-installed. The Interphase Barriers (or Terminal Covers) cannot be used in conjunction with the ring tongue terminal kits. Torque for ring tongue into box lug: 0 lb-in (. N m) Torque for ring terminal: 8 lb-in (.0 N m) Table : UL Recognized Ring Lug Terminal Kit Description Quantity Cat. No. Ring lug terminal kit Two ring tongue terminals Two isolation shrouds Two mm screws 700 99-00 Schneider Electric All Rights Reserved 7

Section Accessories IDENTIFICATION SYSTEM Snap-on Marking Symbols 0800 The Identification System provides marking symbols which can be used on the C0 and NC0 devices. They provide pre-labeled, snap-on plastic clips with one character each. They mount just below the toggle on the C0 devices. The following symbols are available: Blank, 0-9, +, -, and A-Z. Orders must specify standard package quantity of strips of each character or multiples of. NOTE: These are same as markers for Telemecanique AB terminal blocks. IEC Rated; not UL Recognized Table : Snap-on Marking Symbols Marking Quantity Cat. No. Marking Quantity Cat. No. A B C D Strip of Strip of Strip of Strip of ABGA ABGB ABGC ABGD Strip of Strip of Strip of Strip of ABR ABR ABR ABR E F G H Strip of Strip of Strip of Strip of ABGE ABGF ABGG ABGH 7 8 Strip of Strip of Strip of Strip of ABR ABR ABR7 ABR8 I J K L Strip of Strip of Strip of Strip of ABGI ABGJ ABGK ABGL 9 0 Strip of Strip of ABR9 ABR0 M N O P Strip of Strip of Strip of Strip of ABGM ABGN ABGO ABGP 0-9 Strip of ABR Q R S T Strip of Strip of Strip of Strip of ABGQ ABGR ABGS ABGT + - Strip of Strip of ABR ABR U Strip of ABGU V W X Strip of Strip of Strip of ABGV ABGW ABGX Blank Strip of ABRV Y Z Strip of Strip of ABGY ABGZ Label Holder Used to identify a -, -, or -pole C0 or NC0 device. Holds label provided by user. 080 Table : Label Holder Catalog Number Description Cat. No. Label Holder (Bag of ) 70 8 99-00 Schneider Electric All Rights Reserved

Section Accessories OPERATION DEVICES Rotary Handles A C0 or NC0 protection device with -, -, or -poles can be equipped with a Rotary Handle with an extension to allow operation of the circuit breaker from either the front or the side (lateral) from the outside of a panel. The handle requires that an operating subassembly be affixed to the supplementary protector or circuit breaker. This subassembly can be configured in two ways: For front or lateral operation (lateral shown in Figure ) For lateral operation Two versions of the rotary handle are available: The first is a fixed handle for front or lateral mounting on a fixed panel. The second is a draw-out extended handle which may be mounted on a door or hinged panel. It mates with the operating subassembly as the door is closed. Minimum depth for drawout is.8 in. (7 mm) including circuit breaker. Minimum depth for lateral installation is.8 in. ( mm) including circuit breaker. IEC Rated; not UL Recognized Table : IEC Rated Rotary Handles Description US No. IEC No. Operating subassembly for C0 or NC0 protection device (fixed to protection device) Drawout extended handle (mounted on door or hinged panel) Fixed handle front or lateral (mounted on fixed panel) MG70 70 MG707 707 MG708 708 Lateral Rotary Handle Padlock Attachments The Padlock Attachment clips onto the face of the C0N device to prevent the handle from being operated. It cannot be installed or removed when padlocked. No tools are needed to install it. The Padlock Attachment allows the IEC C0 circuit breaker to be locked in either the ON or the OFF position (UL 89 Listed and UL 77 Recognized devices can lock in the OFF position only). The padlock attachment accepts a 0. in. (8 mm) diameter padlock, which is not supplied. The front plate or functional door can be opened with the circuit breaker locked in the OFF position. NOTE: Locking the C0 or NC0 in the ON position will not prevent the device from tripping under overcurrent or ground fault conditions. IEC Rated; not UL Recognized Table : IEC Rated Padlock Attachments Description Quantity US No. IEC No. Padlock attachment for C0 protection device Bag of MG970 970 Strengthened Padlock Attachment for C0N Bag of M9PAF Padlock attachment for NC0 protection device Bag of MG7 7 99-00 Schneider Electric All Rights Reserved 9

Section Accessories MOUNTING ACCESSORIES Plug-in Base 0800 The Plug-in Base allows permanent field wiring connections to be made to the base, so that a C0 device can be plugged in or removed without affecting field wiring. The Plug-in Base kit includes spade connectors which must be installed on the circuit breaker so it will mate with the Plug-in Base. The Plug-in Base provides no-load isolation of a circuit protected by C0 supplementary protectors. While the circuit breaker is removed, the base can be locked using a 0. in. (8 mm) dia. padlock (not provided). Height of base: 7.0 in. (78 mm); with terminal cover extended, 9. in. (7 mm) Allow minimum center spacing of 7.87 in. (00 mm) between two rows of bases Multiple bases may be used for multi-pole devices IEC Rated; not UL Recognized Table : IEC Rated Plug-in Base Description US No. IEC No. Plug-in base for C0 devices MG99 99 Front Mounting Bracket (Kit) 0807 The Front Mounting Bracket provides a convenient way to mount MULTI 9 circuit breakers, supplementary protectors or accessories. Its height is equal to a.8 in. ( mm) DIN rail, and allows the C0 and NC0 devices to be clipped onto it in a standard manner. Its width is available for -, -, -, or -pole devices. In 80 Vac applications, Cat. No. 98 (C0) or 7 (NC0) Terminal Screw Shield should be used for increased isolation between the terminal screws of the MULTI 9 device and the mounting bracket. UL Recognized and IEC Rated Table 7: Front Mounting Bracket Description Size Cat. No. Front mounting bracket for C0 protective devices Front mounting bracket for NC0 protective devices -pole -pole -pole -pole -pole -pole -pole -pole MG98 MG98 MG98 MG989 MG98 MG987 MG988 MG990 NOTE: See dimensional drawings in Section 7. DIN Rail Mounting Clips Additional DIN Rail Mounting Clips for MULTI 9 products are available. Table 8: DIN Rail Mounting Clips 0808 Description DIN Rail Mounting Clip (Bag of 0) Cat. No. MG7 0 99-00 Schneider Electric All Rights Reserved

Section Accessories MSC Mounting Base The MULTI 9 MSC Mounting Base is an integral package that provides DIN mounting of MULTI 9 devices and provides either a -phase or -phase bus bar for up to poles (in two rows) of C0 devices and accessories. The MSC 7 is used for NC0 products. The base is rugged, gloss-white, zinc annealed sheet steel with two rows of DIN mounting rails. The heavy-duty base plate allows surface mounting. The single-piece copper bus conductors are insulated and color-coded. Power may be supplied by a reverse-fed C0 circuit breaker, or via the feed-through connections at the end of the bus. The feed lugs are compatible with COMPACT NS0 molded case circuit breakers and INTERPACT INS-0 switches. Rating: Up to 0 A service Insulation voltage: 90 Vac Current withstand: Peak:. ka Short-time: ka for 0. sec. Phases are color-coded Width: Base 8. in. ( mm); see Table 9 for length Tested to Australian AS9- and AS9- standards (equivalent to IEC 9) IEC Rated; not UL Recognized. Table 9: IEC Rated MSC Mounting Base for MULTI 9 Devices Type Size No. of Poles Base Length (in./mm) Cat. No. MSC DC for C0 protection devices (black, red) -phase 0./.7/ 7.7/8 CDC CDC CDC0 MSC 8 for C0 protection devices (red, white, blue) -phase 8././ 8.8/8 C C8 C MSC 7 for NC0 protection devices (red, white, blue) -phase 8 9.7/./ 9./ C C8 C For overall length, add approximately in. (7 mm) for bus lugs. NOTE: Other options are available by special order, including: lengths up to 8 poles, line feed lugs at one end only, and other variations. Figure : IEC Rated MSC Mounting Base 0809 99-00 Schneider Electric All Rights Reserved

Section Accessories Multi-pole Front Mounting Kit The Multi-pole Front Mounting Kit consists of a transparent, hinged, weatherproof cover with a DIN rail. It allows installation of up to twenty modules ( poles of C0) of MULTI 9 supplementary protectors and accessories. A DIN rail support is also available. Degree of protection as per IEC 9: IP Dimensions (w x h x d): 9. x.9 x. in. ( x x mm) Cutout dimensions: 7. x.78 in. (8 x 9 mm) IEC Rated; not UL Recognized 0808 Table 70: IEC Rated Multi-pole Front Mounting Kit Description Cat. No. Multi-pole front mounting kit with transparent hinged cover (Includes a -module divisible blanking plate and mounting template) DIN-rail support Pole Filler The MULTI 9 M9PF pole filler is used to fill empty panel spaces. They clip into the space. Each M9PF consists of four strips of 8 mm pole fillers. They may be snapped apart in 9 mm increments. Table 7: Pole Filler Description Pole Filler, four strips of 8 mm Cat. No. M9PF 080 99-00 Schneider Electric All Rights Reserved

SECTION ADDITIONAL SYSTEM DEVICES MULTI 9 System Catalog Section Additional System Devices OVERVIEW In addition to the C0 and NC0 Circuit Breakers and Supplementary Protectors which form the heart of the MULTI 9 product line, there are a variety of other devices which may be used with C0 or NC0 devices or as stand-alone devices. These include the following: SPD Surge Protection Devices CM Selector Switches (Change-over) I Isolating Switches OFS Auxiliary Switch Adapter (for IEC CH-DC and ID RCCB devices only) V Signal Lamps and BP Push Buttons CI Impulse Counters and CH Hour Counters IHP Time Switches NOTE: See Section for IEC Rated Ground-fault Protection Devices. All of these devices adhere to the MULTI 9 packaging format, and can be mounted on a DIN rail in the protection and control cabinet. SPD Surge Protective Device 080 SPD Module The SPD (Surge Protective Device) offers an ideal solution for protecting equipment from the damaging effects of power surges. These DIN-rail mountable devices include -, - and -pole models that are mounted in parallel with the load to provide up to 80,000 amps of surge protection. They can be used in conjunction with the MULTI 9 family of products to provide a uniform solution for your application and ensure superior OEM design flexibility. This product line is available in most international voltages for both single-phase and three-phase power systems. Figure : SPD Surge Protective Devices 080 080 -Pole -Pole -Pole 080 Table 7: Description Specifications for UL 9 SPD Surge Protective Devices Specification Maximum Surge Current/Phase 0 ka, ka, ka, 80 ka (refer to table) Service Voltages: 0, 0, 08Y/0, 00Y/0 Operating Frequency 0/0/00 Hz Poles,, and poles Dry Contacts for Remote Status Available in some models Termination # to # AWG ( mm²) Terminal Torque lb-in ( N m) Dimensions (width) -pole = 8 mm, -pole = mm, -pole = 89mm Housing Rating Type, (IP0) Operating Temperature - to +0 F (-0 to +70 C) Product Standards UL 9 Second Edition and CSA C. No. 0 M9, IEC - 99-00 Schneider Electric All Rights Reserved

Section Additional System Devices Table 7: UL Recognized MULTI 9 SPD Series Transient Voltage Surge Suppressor (TVSS) Service Voltage U N (Vac) No. of Poles Connector for Remote Monitoring Max Surge Current/Phase I MAX (ka) UL Suppressed Voltage Rating (SVR) L-N (Vac) Cat. No. Replacement Module Cat. No. NO Common NC Connector for Remote Monitoring (Refer to Table 7 for Availability) 080 0 0 00 0 0 0 0 00 00 0 0 0 No No No No Yes No Yes No Yes No Yes No 0 0 0 00 700 00 00 00 700 700 00 00 00 00 700 7 7 7 7 7 7 7 77 78 79 70 7 7M 7M 7M 7M 7M 7M 7M 77M 78M 79M 70M 7M 0 00 00 Yes No Yes 700 00 00 7 7 7 7M 7M 7M 0 No 0 00 7 0 0 0 08Y/0 No No No No 0 0 700 00 700 00 7 77 78 79 08Y/0 00Y/0 00Y/0 08Y/0 Yes No Yes No 0 0 0 00 700 700 00 70 7 7 7 08Y/0 00Y/0 00Y/0 08Y/0 Yes No Yes No 80 00 700 700 00 7 7 7 77 08Y/0 00Y/0 00Y/0 Yes No Yes 80 80 80 00 700 700 78 79 70 Cable Range: # # AWG ( mm²) Widths: pole = 8 mm, poles = mm, poles = 89 mm NOTE: See Class Catalog (document no. CT0) for recommended protection of the SPD. Figure 7: SPD Surge Protective Devices Wiring Schematics L L N L L L N 080 080 080 -Pole -Pole -Pole G G G 99-00 Schneider Electric All Rights Reserved

Section Additional System Devices CM Selector Switches 080 The CM Selector Switch allows manual selection of circuits. Different models are available to allow selection of two or three positions (including off) for one or two circuits. They have maximum ratings of 0 A and 0 Vac. This device may be installed on the DIN rail adjacent to the C0 device and its accessories or remotely in a user interface panel. IEC Rated; not UL Recognized Table 7: IEC Rated CM Selector Switches CM Selector Switch Type No. of Circuits No. of Positions Width in Modules Cat. No. 9 8 0 8 Figure 8: IEC Rated CM Selector Switch Schematics 0800 Two Position Green N 080 Three Position Green N 0 L Red L Red Load Load 99-00 Schneider Electric All Rights Reserved

Section Additional System Devices I Isolating Switch 080 The I Isolating Switch provides manual on-load opening or closing of a circuit. Note that it does not provide either thermal or magnetic protection. It can be used with the OF auxiliary switch and with other non-electrical accessories in the C0 family. This device may be installed on the DIN rail adjacent to the C0 device and its accessories or remotely in a user interface panel. IEC Rated; not UL Recognized Table 7: IEC Rated I Isolating Switches Rating (A) -pole (0 Vac) Modules -pole ( Vac) Modules -pole (0 Vac) Modules -pole ( Vac) Modules -pole (0 Vac) Modules -pole ( Vac) Modules -pole (0 Vac) 8 Modules -pole 0 0 00 009 0 0 00 0 00 0 007 0 0 0 008 0 09 0 0 090 07 09 08 09 09 09 00 Figure 9: I Switches 080 080 080 -pole -pole -pole OFS Auxiliary Switch Adapter (for ID RCD) 080 The OFS Auxiliary Switch Adapter allows the ID Residual Current Switches (in Section ) to use the same electrical accessories as the C0 supplementary protectors, including the OF Auxiliary Switch, SD Alarm Switch, MN Undervoltage Release, and/or MX + OF Shunt Trip. IEC Rated; not UL Recognized Table 7: OFS Auxiliary Switch Description Cat. No. OFS auxiliary switch 9 99-00 Schneider Electric All Rights Reserved

Section Additional System Devices STATUS, DISPLAY AND CONTROL ACCESSORIES There are a variety of other accessories which may be used with the C0 or NC0 devices to communicate control and/or status information. These include the following: V Type Signal Lamps BP Push Buttons CH Hour Counter CI Impulse Counter IHP Time Switches These accessories may be located adjacent to the C0 or NC0 or may be located remotely. V Signal Lamp The V Type Signal Lamp indicates when voltage is applied to a circuit and may be used with MULTI 9 circuit protection systems or other applications. The lenses are available in a variety of colors. Bulbs are available for 0 Vac and,, or 8 Vac/Vdc operation. This accessory device may be installed on the DIN rail adjacent to the C0 devices and its accessories or remotely in a user interface panel. NOTE: IEC Rated; not UL Recognized 0807 Table 77: IEC Rated V Signal Lamps and Accessories Type Width in Modules Voltage Color Cat. No. Complete V signal lamp 0 Vac Clear Red Green Yellow Blue 7 8 9 V signal lamp without bulb or lens Lens (bag of ) Clear Red Green Yellow Blue Accessories Clear, red, 0 Vac yellow () Bulbs (bag of ) Blue, green () 8 Vac/Vdc Vac/Vdc Vac/Vdc All All All 7 8 9 According to lens color. Figure 0: IEC Rated V Signal Lamps 080 99-00 Schneider Electric All Rights Reserved 7

Section Additional System Devices BP Push Buttons 08008 The BP Push Button device may be used to control MULTI 9 circuit protection systems or other equipment. It provides momentary switching and is available with one N.O., one N.C., or combined with one each N.O. + N.C. contact. It is available with or without a signal lamp, which is available in a variety of colors. This device may be installed on the DIN rail adjacent to the C0 and its accessories or remotely in a user interface panel. NOTE: IEC Rated; not UL Recognized Push Buttons without Signal Lamps Table 78: Type Catalog Numbers for BP Push Buttons Type Width (In Modules) Voltage Signal Lamp Color Push Button Color Cat. No. 0807 Push buttons without signal lamps Push buttons with signal lamps O + C C O C O Red Green Gray Red Green Red Green 7 8 0 Vac Green Red Push Buttons with Signal Lamps Bulb (bag of ten) Lens (bag of five) 8 Vac/Vdc Vac/Vdc Vac/Vdc All All All Green Red 7 8 9 Figure : IEC Rated BP Push Button Types 0809 O + C C O C O x x x x Push Buttons without Signal Lamps Push Buttons with Signal Lamps CH Hour Counter 080 The CH Hour Counter is used for measuring the total operating time of a circuit or load. It is capable of counting to a maximum of 99,999.99 hours. It operates on 0 Vac, 0 Hz. The CH must be installed downstream of a circuit breaker or supplementary protector. The CH Hour Counter is useful for metering of activity or for scheduling maintenance. This device may be installed on the DIN rail adjacent to the C0 and its accessories or remotely in a user interface panel. NOTE: IEC Rated; not UL Recognized Load CH 8 99-00 Schneider Electric All Rights Reserved

Section Additional System Devices CI Impulse Counter 0808 The CI Impulse Counter is an electromechanical counter designed to measure impulses produced by various devices. It displays the running total of metered impulses. The CI Impulse Counter is unaffected by interruptions in the main power supply. It is most suitable for counting impulses emitted by detectors such as kilowatt-hour metering, temperature overrun, etc. This device may be installed on the DIN rail adjacent to the C0 device and its accessories or remotely in a user interface panel. Figure : IEC Rated CI Impulse Counter N L N L 080 CI Kilowatt Meter (Wh) CI Load Load NOTE: IEC Rated; Not UL Recognized Table 79: CH Hour Counter and CI Impulse Counter Type Voltage (Vac) Frequency (% to +%) Width in Modules Cat. No. CH 0 0 0 Hz 0 CI 0 0 0/0 Hz IHP Time Switch 080 The IHP Time Switch controls the opening and closing of one or more separate circuits according to the programming set by the user. The sequences are repeated daily ( hour) or weekly (7 day). Their compact dimensions, 0.7 in. (8 mm) width, makes them ideal for small enclosures. They may be used to control heating, lighting, watering, or other cyclic processes. Table 80: IHP Time Switch Specifications The IHP Time Switch is programmable through the front panel Accuracy: ± s per day at 8 F (0 C); quartz time base Contact Rating: A, 0 Vac, (cos φ = 0.) Connection: Tunnel terminals for cables up to # AWG ( mm ) Power Consumption: VA Ambient temperature: to F (- to 0 C) Complies with Standard EN 070 and UL IEC Rated UL Recognized Table 8: Catalog Numbers for IHP Time Switches Type Cycle Period Min. Time Between Operations No. of Channels Voltage Frequency Battery Max. No. of Switching Operations Standards Cat. No. Programmable time switch (IHP) 7 days min. 0 Vac ±% 0/0 Hz Yes 8 x 7 UL 80 7 days min. 0 Vac ±% 0/0 Hz Yes x 7 UL 8 99-00 Schneider Electric All Rights Reserved 9

Section Additional System Devices KAEDRA WEATHERPROOF DIN TYPE ENCLOSURES Applications Extension enclosure for service, industrial, or equipment applications Protects against water, dust, and chemical and atmospheric agents KAEDRA mini-enclosures are designed for small installations ( to modules) replacing MINI- PRAGMA weatherproof enclosures. KAEDRA enclosures come in seven sizes from to 7 modules (8 mm per module) Standard Features IP : as per IEC 09 for protection against ingress of solid and liquid bodies IK09: Protection against shocks and resistance to chemical and atmospheric agents, ultraviolet light, etc. Class : Total insulation Flame and abnormal heat resistance: 70 C as per IEC 09-- Conformity with IEC 70 standard for empty enclosures and with IEC 9- standard for equipped switchboards. It is made of insulating material, Class, and can be sealed and/or locked (key-lock or insert). It complies with IEC 09- Standards. Construction Non-metallic (styrene) modern, sturdy appearance in light gray RAL 70; smooth surfaces and rounded corners to increase impact strength. Transparent (green) door for immediate visibility; door can be mounted left or right with clip-on hinges; secure closing due to multiple latching points; door may be locked to limit access. Punchout holes on four sides and back enable cable insertion throughout. Installation Can be installed horizontally and/or vertically Enclosures can be combined and added at any time using the association kits to provide mechanical connection and cable routing. Cabling is quick and efficient, with the provided terminal blocks and wiring straps. Distance between rails (, 0, 7 mm) and rail depth are adjustable. Chassis can be removed for assembly of equipment Function identification with a clip-on label with protection cover. Table 8: Catalog Numbers for KAEDRA Weatherproof Mini-Enclosures 0800 KAEDRA Weatherproof Mini-Enclosure Dimensions Description W H D Cat. No. in. mm in. mm in. mm Row of Modules. 80.9 0.8 98 9 Row of Modules.8 7.87 00. 97 Row of Modules. 9 7.87 00. 98 Row of 8 Modules 7.8 9 7.87 00. 99 Row of Modules. 7 7.87 00. 90 Accessories include: Terminal blocks and terminal block support; marking kit; Class II plugs Enclosure modules are 8 mm wide. NOTE: The KAEDRA Weatherproof enclosures replace the MINI-PRAGMA enclosures. 0 99-00 Schneider Electric All Rights Reserved

Section Additional System Devices Table 8: Catalog Numbers for KAEDRA Weatherproof Enclosures 0800 KAEDRA Weatherproof Enclosure Dimensions Description W H D Cat. No. in. mm in. mm in. mm Row of Modules.9 0.0 80. 0 9 Rows of Modules.9 0 8. 0. 0 9 Rows of Modules.9 0.0. 0 9 Row of 8 Modules.9 0.0 80. 0 9 Rows of 8 Modules.9 0 8. 0. 0 9 Rows of 8 Modules.9 0.0. 0 97 Rows of 8 Modules.9 0. 8. 0 98 Accessories include: Terminal blocks and terminal block support; marking kit per row; wiring strap per row; Class II plugs, and blanking plates ( x 8 mm modules per row) Enclosure modules are 8 mm wide. Accessories Necessary accessories are included with enclosure, including: Terminal blocks and terminal block support; one marking kit; Class II plugs Other options available are listed in Table 8. Table 8: Description KAEDRA Weatherproof Enclosure Accessories Cat. No. Association Kit ( sleeves + nuts + washers) 9 Blanking Plate (set of x modules) 90 Sealing Kit ( screws, fasteners) 97 Keylock (Eurolock no. 80) 98 Plain Front Plate, modules 9 Plain Front Plate, 8 modules 9 Cable Gland, PG (0.7 in./8. mm) 899 Cable Gland, PG. 899 Cable Gland, PG (0.88 in./. mm) 899 Cable Gland, PG (. in./8. mm) 899 Cable Gland, PG9 (.7 in./7 mm) 899 Cable Gland, PG (.8 in./7 mm) 8997 99-00 Schneider Electric All Rights Reserved

Section Additional System Devices MINI PRAGMA DIN TYPE ENCLOSURES Applications Extension enclosure for individual and institutional housing Sub-distribution enclosure in service sector buildings Rated current: A Standard Features Material: Insulating, self-extinguishing material White color Standards: International IEC 9. French NF C.9 Degree of protection: IP 0 as per IEC 9 Mechanical impacts: IK 07 as per EN 0. Class : Total insulation Behavior in fire and abnormal heat as in IEC 9.. in accordance with ERP and IGH (high-rise building) regulations Construction Figure : Mini PRAGMA DIN Type Enclosures 0809 Table 8: 0809 Enclosures (one row with transparent door) Back with a central hole to simplify installation and two oblong holes for leveling. Punch-out holes on the top, bottom and back surfaces enable cable insertion throughout. Axis placed on the back/front panel parting line ensures easy, neat punch-outs using pliers. Metal rail centered at mid-height, and sufficiently far from the back to enable wire insertion Rigid, sealable, front panel Plain or transparent, rounded and flush door A key lock is optional Number of 0.7 in. (8 mm) Modules Dimensions (in./mm) H L D Cat. No. 7.9/0./.70/9 7.9/0.8/8.70/9 7 8 7.9/0 7./8.70/9 8 7.9/0.0/.70/9 9 99-00 Schneider Electric All Rights Reserved

Section Additional System Devices Accessories Sloping terminal block support to simplify cable insertion and improve accessibility on clamping Terminal block equipped with guides to simplify cable introduction in tunnels Four holes for - and -module enclosures: () x 0.0 sq. in. ( mm ) + () x 0.0 sq. in. ( mm ) Eight holes for 8- and -module enclosures: () x 0.0 sq. in. ( mm ) + () x 0.0 sq. in. ( mm ) Built-in divisible blanking plate: Two modules Identification strip Four sealing plugs for wall fastening screws (required for Class ) Table 8: Mini PRAGMA Accessories Accessory Sealing kit Key lock Extra terminal block for ground or neutral A strip of ten extra blanking plates dividable per module of 0. in. (9 mm) Cat. No. 9 80 7 9 PRAGMA F DIN TYPE ENCLOSURES Applications Indoor enclosures Creation of sub-distribution boards for small and medium service sector buildings (hotels, offices, shops) and switchboards for medium and large residential installations Switchboard rated current: 0 A Standard Features Material: Metal back, ivory color Standards: International IEC 9., French NF C.9 Degree of protection against mechanical impacts as per IEC 9: Enclosure without door: IP 0 Enclosure with door: IP D Degree of protection against mechanical shocks as in EN 0 : IK 08 Insulation: Class : Standard Class : Total insulation Fire and abnormal heat withstand in accordance with regulations for buildings open to the public (BOP) and high-rise buildings (HRB) 99-00 Schneider Electric All Rights Reserved

Section Additional System Devices Construction Figure : 0809 PRAGMA F DIN Type Enclosures Metal back (fully insulated for Class enclosures), with removable chassis One insulated front panel frame Insulated modular front plates Insulated plates with knockouts Accessories Included One ground/neutral () 0-hole terminal blocks: () x 0.0 in. sq. ( mm ) + () x 0.0 in. sq. ( mm ) + () x 0.0 in. sq. ( mm ) Terminal block equipped with guides to simplify cable introduction in tunnels Eight module divisible blanking plates: Two blanking plates for one, two and three row enclosures Four blanking plates for four, five and six row enclosures Label with protective cover for each row Table 87: PRAGMA F Type Enclosures Rows Number of Modules Dimensions (in./mm) Cat. No. 0.7 in. (8 mm) H W D 8 7 9.8/00 7.7/0./00 9./70./0./0./0./0.9/70.9/70.9/70.9/70 8 8 8 8 0./900./0./0./0.9/70.9/70 8 8 Blanking Plate for PRAGMA F Type Enclosures (7 in./0 mm) 0 Enclosure modules are 8 mm wide. 99-00 Schneider Electric All Rights Reserved