Innovation in Magnetic Field Measuring Instruments. Grad601. Magnetic Gradiometer System

Similar documents
Data Acquisition & Signal Conditioning Units

Innovation in Magnetic Field Measuring Instruments. Mag648 & Mag649. Low Power Three-Axis Magnetic Field Sensors.

Spectramag-6 Six-Channel Spectrum Analyser for Magnetic Field and Vibration Surveys. For innovation in magnetic measuring instruments

INNOVATION IN MAGNETICS DS0070/12. Mag-01H D/I. Declinometer/Inclinometer System.

INNOVATION IN MAGNETICS DS-2201/8 DAS1. Data Acquisition System.

Innovation in Magnetic Measuring Instruments. Data Acquisition & Conditioning Units

INNOVATION IN MAGNETICS DS0013/27. Mag-03. Three-Axis Magnetic Field Sensors.

Spacemag & Spacemag-Lite

Mag-03. Three-axis Magnetic Field Sensors. For innovation in magnetic measuring instruments

Mag-03. Three-Axis Magnetic Field Sensors.

Mag-01H. Fluxgate Declinometer/Inclinometer. Mag-01H D/I. World leaders in high precision magnetic field measurements

HCS1 Three-Axis Helmholtz Coil System

Operation Manual for Mag612 Three-Axis Magnetic Field Probe

Innovation in Magnetic Field Measuring Instruments. Mag-03. Three-Axis Magnetic Field Sensors.

Mag High Temperature Three-Axis Magnetic Field Probes

Operation Manual for. Geolabsoft for Windows (PC version)

Innovation in Magnetic Measuring Instruments. Mag-03. Three-Axis Magnetic Field Sensors

Operation Manual for. Mag-01 & Mag-01H Single Axis Fluxgate Magnetometers with Mag Probes B-G

Contact: Locators & Supplies, Inc. (800) GatorCam4 system

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Operation Manual for. Mag628/629 and Mag669 Three-Axis Aerospace Magnetometers.

Gas detection just got personal

Keysight U8030 Series Triple-Output DC Power Supplies

Handout. and. brief description. Marine Gravity Meter KSS 32- M

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Technical Hotline: (800)

Hand-held thermometer Model CTH7000

Precision thermometer Model CTR5000

UtilityScan TM. Locate and Map Underground Utilities with GPR. Typical Uses. Designate Targets.

INNOVATUM REFERENCE MANUALS. Section 4-1. Smartrak Description & Installation

Programmable DC power supplies

ALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. ALMEMO V7 Measuring Instrument

2D Horizontal Profiler khz

Single-point current meter designed for very long-term deployments

DCT7088 Portable Digital Correlation Transit Time Flowmeter

Digital Video Inspection

vlocdm2 Rx & Loc-150Tx Data Sheet V1.6

360W and 720W Programmable DC Power Supplies

DM650TM SENSOR / WALL MOUNTED TEMPERATURE DISPLAY

DC resistance thermometry bridge Model CTR6000

N420 R420 R423. series

innovative technology to keep you a step ahead

Trend-1 Vibration Data Logger. User Manual

CRIBS Installation and User Guide

VIAVI Seeker D Lite. Data Sheet. Shielding Integrity Testing Kit A Trilithic Series Leakage Solution. Overview. Key Features. In-Home Leakage Detector

Uninterruptible Power Supplies

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

Vibration Meter SD Card real-time datalogger

VIBRATION METER Model : VB-8213

DM650VI SENSOR/WALL MOUNTED VOLTAGE/mA DISPLAY

THURLBY THANDAR INSTRUMENTS. PL & PL-P Series. Laboratory Power Supplies. Standard and Programmable models, 35 watts to 240 watts

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

POWERGORILLA POWERGORILLA TACTICAL 5V TO 24V RUGGED HIGH TECH CHARGER USER GUIDE

IRM-5000P. insulation resistance meter. Vanguard Instruments Company, Inc.

Installation Manual for D24XX Series of 24V Switched Mode Power Supplies

The 2003/4 includes: Ground Penetrating Radar Detector, Joystick to manually transmit pulses, computer cable for

E101 - Strain Gauge Transducer Display Module. Contents

Model KT 53 Cooling incubators with thermoelectric cooling

Aquadopp Profiler 1 MHz

HOBO Motor On/Off Data Logger (UX90-004x) Manual

Hygro-Thermometer / Datalogger

Sample 3D velocity at up to 64 Hz for small-scale research in coastal areas

Millenium II +: general characteristics

THE TECHNOLOGY BEHIND THE MEASUREMENT

ARES II AUTOMATIC RESISTIVITY & IP SYSTEM

Operating Manual RISH DPM Hz

TAG GD3030 rugged tablet

THREE-AXIS HALL MAGNETOMETER THM1176 TECHNICAL SPECIFICATIONS

FG-7000L Digital Force Gauge Operation Manual

Installation Manual for D244X Series 24-volt Power Supplies

Power Analyzer Datalogger Model

Air Ion Counter - Operation Manual MOC 320 Oct. 16

ECV ecompass Series. Technical Brief. Rev A. Page 1 of 8. Making Sense out of Motion

ARX 308 User Reference Manual

Optical CWDM Power Meter

Portable Ground Control Station

Multi-Function Ground Resistance Tester Model 6471

PM-204A/B. Power Meter. Operation Guide

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

PWS500S Installation Guide

MEXICO (52) NETHERLANDS (31) SINGAPORE (65) SOUTH AFRICA (27) / 5 SPAIN (34)

Hand-held thermometer Model CTH7000

CALYS 50. Field multifunction calibrator for basic use. Calibration measurement

HOBO Light On/Off Data Logger (UX90-002x) Manual

BAC GLOBAL SURVEYOR Mk

Model HM-535 Power Supply Installation and Service Instructions

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz Product Overview

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

ARP992/ ARP992-B User Reference Manual

Product Identification Product name Package Noise* Range in µt Mag-03 MC= Cylindrical B = Basic ±70 MCES = Cylindrical, environmentally sealed to IP64

Circuit Breaker Analyzer & Timer CAT31

DATALOGGER. SD card, real time OPERATION MANUAL. Model : DL-9602SD

ARL992/ ARL992-B User Reference Manual

TAG GD700 rugged tablet

OPERATION MANUAL. auto range + type K Temp. optional Humidity, Light, Anemometer SOUND LEVEL METER Model : SL-4112

OPERATION MANUAL. SD card real time data Recorder, USB/RS232 SOUND LEVEL METER. Model : SL-4023SD. Your purchase of this

Dräger UCF 6000 Thermal Imaging Camera

PV Remote Unit A 1378 Instruction manual Version 2.1, Code no

Rotary Position Technology Incremental Encoders

DIGITAL PRESSURE SENSOR SCANNER CUM DATALOGGER

Power Panel Integrated control, operation and visualization

Transcription:

Innovation in Magnetic Field Measuring Instruments Grad601 Magnetic Gradiometer System

Grad601 Magnetic Gradiometer System Bartington Grad601 Magnetic Gradiometer System The Grad601 is a fluxgate gradiometer, used for measuring minute variations in the magnetic field that are caused by hidden anomalies in the ground such as archaeological features, geophysical features, pipes, cables, waste drums, unexploded ordnance, and other signs of human activity. The full system comprises a Data Logger (DL601), a battery cassette (BC601), and either one or two Grad-01-1000L sensors mounted on a rigid carrying bar together with a carrying harness (Grad601-2 only). Calibration is made easy via simple push-button control. The Data Logger s non-volatile flash memory will hold surveyed grids. These can be downloaded as individual files, so different size grids may be recorded during a survey. Features Electronic adjustment Push button operation Available modes: Grid (Scan or Survey) and NMEA (Run) Selectable resolution 0.01nT or 0.1nT (Grid mode); 0.1nT (NMEA mode) Exceptional temperature stability ensures minimal drift and reduces need for adjustment One metre baseline provides ideal depth response for distinguishing important sub-surface features 50Hz or 60Hz electricity power line rejection Low power consumption allows 24 hour operation with two sensors Typical Applications Archaeological prospecting Forensics Unexploded ordnance (UXO) detection Pipe, cable and drum location Bartington is a registered trade mark of Bartington Instruments Limited in the following countries: United Kingdom, Australia, Brazil, Canada, China, European Union, India, Japan, New Zealand, Norway and the United States of America.

www.bartington.com Components The Grad601 system includes the following components: Grad-01-1000 sensor(s) DL601 Data Logger BC601 Battery Cassette and charger Single or dual-sensor carrying bar and associated cables Carrying harness (Grad601-2 only) Grad-601 DATALOG downloading software and USB to RS232 converter Carrying case. Alternative Configurations The Grad601 can be used as either a dual sensor system (for best survey speed) or single sensor system (for confined spaces). Conversion: Grad601-2 dual to Grad601-1 single system Grad601-1 single to Grad601-2 dual system Additional parts required: Single sensor carrying bar + BC601 battery cassette extension cable Dual-sensor carrying bar and harness + Grad-01-1000L Sensor Specifications Environmental Operating temperature Rating -20 C to +70 C IP65 Mechanical Weight Grad601-1 Single Sensor 2.9kg Grad601-2 Dual Sensor Harness with abdominal spacer and balance weight Carrying case for either system (dimensions 1250 x 280 x 260mm) 4.3kg 1.6kg 9.85kg (empty) 15.75kg (full Grad601-2)

Grad601 Magnetic Gradiometer System Bartington Grad-01-1000L Sensor The Grad-01-1000L is a high stability fluxgate gradient sensor, with a 1m separation between the sensing elements and an effective sensitivity of 0.03nT/m. The exceptional temperature stability of this sensor ensures minimal drift during surveys, and reduces the need for adjustment to a minimum. Each sensor contains electronics and nonvolatile memory for calibration data storage, and can be operated independently, over long cables, if required. The sensors may also be fitted to the Non-Magnetic Cart, also available from Bartington Instruments, for surveys over wider areas. Specification Number of axes Sensor element spacing Gradient range Bandwidth Sensitivity One (vertical) 1m ±100nT/m or ± 1000nT/m full-scale DC to 14Hz with -40dB 50Hz/60Hz rejection 0.03nT/m (max effective) Calibration error ±2% Maximum ambient field Drift Dimensions Weight Connector Power supply current Minimum sensor spacing in multi-sensor array ±100μT <1nT in 24 hours 38mm diameter x 1050mm in length 0.83kg 12-way Tajimi R04-R12M 60mA 250mm between sensors

www.bartington.com DL601 Data Logger The Data Logger stores collected grids. These can be downloaded to a PC using either a serial RS232 cable connected directly to an RS232 port on the PC, or a USB to RS232 converter cable connected to the USB port of the PC. Data is made available in any of three formats for subsequent data processing. All functions are selected via a simple six-key control panel and LCD display. The Data Logger can be set to either Grid or NMEA survey mode by the operator. Grid mode saves survey data in predefined grid format; NMEA mode sends data through to a PC in real time using NMEA format. It is then associated with location information to produce a reliable map of the survey site regardless of the surveyor s course. The Data Logger measures the magnetic gradient during surveys using a high sampling rate, with automatic averaging for each reading. Sampling rate can be adjusted to suit the operator s pace. Specification Sensors Gradient ranges Resolution Attenuation Control delay Controls Display Display update rate Gradiometer adjustment Data logging memory Data output Audio output Dimensions (H x W x D) Weight Connectors: Grad-01-1000L RS232 output Battery External switch Power supply requirements Survey mode 1 or 2 Grad-01-1000L Sensors ±100nT and ±1000nT 0.01nT on ±100nT range (Grid mode)* 0.1nT on ±1000nT range (Grid mode) and on all ranges in NMEA mode -20dB 50Hz/60Hz rejection 27ms ON/OFF switch, keypad and external switch 2 rows x 20 characters LCD Operation dependent Automatic via keypad 125k data points non-volatile RS232 interface USB converter supplied NMEA output available Variable rate bleeper 160 x 80 x 60mm 0.49kg Two 12-way Tajimi R04-R12F 9-way D type 2-way Amphenol 62GB-57A8-2P 3-way series 712 subminiature 9V-18V DC, 45mA (max) 1 to 4 lines/m 1 to 8 readings/m along each line (4 max on 40m grids) Capacity to store 125k readings * Effective resolution with Grad-01-1000L Sensor is 0.03nT/m.

Grad601 Magnetic Gradiometer System Bartington BC601 Battery Cassette The Lithium Ion battery is housed in a sealed cassette, which also contains the charging circuitry. The battery is charged by the mains adaptor supplied, or any isolated 9-18V DC supply (at 1.2A minimum) in 6 to 8 hours. One charge will operate the system for up to 24 hours with two sensors, or 36 hours with one. A push-button charge indicator is provided. Specification - BC601 Battery Cassette Battery Battery charging Indicators Fuse Dimensions (H x W x D) Weight Connectors: charger input output 10.8V 72Wh UN approved Lithium ion battery 6 to 8 hours with mains adaptor supplied (automatic termination) Red LED lit when charging, off when complete 2A 20mm anti-surge internal 120 x 210 x 25mm 0.91kg including battery 2.1mm socket 2-way 62GB type on 250mm cable Grad601 Carrying Bar An appropriate carrying bar is supplied for each configuration, Grad601-1 or Grad601-2. The sensors are attached at the ends of the carrying bar by quick release clamps. The data logger and battery cassette are normally left attached to the carrying bar. All cables are routed through the carrying bar. For ease of use during surveys, green and red push-buttons are provided on the carrying bar, near the operator s hand, as alternatives to the keypad ENTER and ESC keys. The dual-sensor carrying bar is attached by swivel mounts to an abdominal spacer bar to assist in keeping the sensor vertical. The spacer bar is attached to the harness by shock absorbing rubber rings.

www.bartington.com Accessories Each gradiometer system is supplied in a universal rugged carrying case with cutouts for either a single or dual system, together with: Carrying harness with spare rings (Grad601-2 only). The harness can be adjusted to fit the operator and enables the gradiometer to be positioned at the required carrying height. A bag in the back of the harness can be water-filled to counter balance the instrument. Mains adaptor: 110V-240V/47-63Hz, charging current 1.25A maximum In-car charger: regulated 12V-24V DC-DC, 2A current rating, short circuit protected, automatic thermal and overload cut-off 9-pin serial cable and USB adaptor Downloading software on CD Grad601 Operation Manual on CD Software Most users will find that processing and interpretation of survey results is greatly simplified if graphical mapping software is used. The typical graphical image plots shown here indicate how detected features can be clearly identified. Grad601 Download Software This utility is supplied free of charge and allows survey data to be downloaded to a Windows PC. Several file formats (including xyz, z data and spreadsheet mode ) are available, and are compatible with most common mapping software packages (e.g. Surfer, Geoplot). The plots on the right illustrate how the 1m vertical spacing of the sensors on the Grad601 provides an increased depth of response compared to a 0.5m spacing gradiometer. TerraSurveyor by DW Consulting TerraSurveyor (formerly ArcheoSurveyor) is a fully featured and powerful graphical imaging application, specifically designed for archaeological geophysics. It can read data directly from the Grad601 Gradiometer (and other commonly used survey instruments such as resistivity) via the serial/usb connection. The user can then apply a wide variety of data filters and algorithms (e.g. clip, destripe, destagger, etc.) to enhance the clarity of any magnetic anomalies. TerraSurveyorLite is a lite version of this graphical mapping software, providing the user with the majority of functions needed to process instrument data. There is a simple upgrade path to the full version when further features become necessary. TerraSurveyor and TerraSurveyorLite demonstration versions can be downloaded from the DW Consulting website at www.dwconsulting.nl. Example of survey from Grad601-2 plotted in TerraSurveyor

DS1800/21 T: +44 (0)1993 706565 F: +44 (0)1993 774813 E: sales@bartington.com Bartington Instruments Limited 5 Thorney Leys Business Park Witney, Oxford, OX28 4GE, England. The specifications of the products described in this brochure are subject to change without prior notice.