PET Quantification using STIR

Similar documents
Workshop on Quantitative SPECT and PET Brain Studies January, 2013 PUCRS, Porto Alegre, Brasil Corrections in SPECT and PET

STIR SOFTWARE FOR TOMOGRAPHIC IMAGE RECONSTRUCTION

Modeling and Incorporation of System Response Functions in 3D Whole Body PET

NRM2018 PET Grand Challenge Dataset

Performance Evaluation of radionuclide imaging systems

Customizable and Advanced Software for Tomographic Reconstruction

Review of PET Physics. Timothy Turkington, Ph.D. Radiology and Medical Physics Duke University Durham, North Carolina, USA

Implementation and evaluation of a fully 3D OS-MLEM reconstruction algorithm accounting for the PSF of the PET imaging system

STIR: Software for Tomographic Image Reconstruction Release 2

STIR User s Meeting. Reconstruction of PET data acquired with the BrainPET using STIR. 31. October 2013 Liliana Caldeira

Improvement of contrast using reconstruction of 3D Image by PET /CT combination system

Effect of Scatter Correction When Comparing Attenuation Maps: Application to Brain PET/MR

Investigation of Motion Induced Errors in Scatter Correction for the HRRT Brain Scanner

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

Hammersmith. Imanet. Image Reconstruction STIR. Software for Tomographic.

Introduction to Positron Emission Tomography

A Scatter Calibration Technique for Dynamic Brain Imaging in High Resolution PET

STIR. Software for Tomographic Image Reconstruction. Kris Thielemans

Exercises Instructions

REMOVAL OF THE EFFECT OF COMPTON SCATTERING IN 3-D WHOLE BODY POSITRON EMISSION TOMOGRAPHY BY MONTE CARLO

Image reconstruction for PET/CT scanners: past achievements and future challenges

8/2/2017. Disclosure. Philips Healthcare (Cleveland, OH) provided the precommercial

QIBA PET Amyloid BC March 11, Agenda

Semi-Quantitative Metrics in Positron Emission Tomography. Michael Adams. Department of Biomedical Engineering Duke University.

Introduc)on to PET Image Reconstruc)on. Tomographic Imaging. Projec)on Imaging. Types of imaging systems

664 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 3, JUNE 2005

Simulations in emission tomography using GATE

Effect of normalization method on image uniformity and binding potential estimates on micropet

Pragmatic fully 3D image reconstruction for the MiCES mouse imaging PET scanner

High Temporal-Resolution Dynamic PET Image Reconstruction Using A New Spatiotemporal Kernel Method

1018 IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 27, NO. 8, AUGUST 2008

Effect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis

3-D PET Scatter Correction

Pragmatic Fully-3D Image Reconstruction for the MiCES Mouse Imaging PET Scanner

Introduction to Emission Tomography

3D-OSEM Transition Matrix for High Resolution PET Imaging with Modeling of the Gamma-Event Detection

Performance Evaluation of the Philips Gemini PET/CT System

Fully 4D List-Mode Reconstruction with Temporal Basis Function Estimation

Outline. What is Positron Emission Tomography? (PET) Positron Emission Tomography I: Image Reconstruction Strategies

Respiratory Motion Compensation for Simultaneous PET/MR Based on Strongly Undersampled Radial MR Data

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition

NIH Public Access Author Manuscript J Nucl Med. Author manuscript; available in PMC 2010 February 9.

Attenuation map reconstruction from TOF PET data

Compression of Dynamic PET Based on Principal Component Analysis and JPEG 2000 in Sinogram Domain

USING cone-beam geometry with pinhole collimation,

SPECT reconstruction

Comparison of 3D PET data bootstrap resampling methods for numerical observer studies

Statistical Methods for Reconstruction of Parametric Images from Dynamic PET Data

Automatic Lesion Detection for Measuring Response using Dynamic FDG-PET

Assessment of OSEM & FBP Reconstruction Techniques in Single Photon Emission Computed Tomography Using SPECT Phantom as Applied on Bone Scintigraphy

University of Groningen

Constructing System Matrices for SPECT Simulations and Reconstructions

Evaluation of Penalty Design in Penalized Maximum- likelihood Image Reconstruction for Lesion Detection

8/1/2017. Current Technology: Energy Integrating Detectors. Principles, Pitfalls and Progress in Photon-Counting-Detector Technology.

Reconstruction from Projections

Characterization of a Time-of-Flight PET Scanner based on Lanthanum Bromide

STIR General Overview Kris Thielemans version 2.3

Q.Clear. Steve Ross, Ph.D.

Factors influencing image quality and quantification: optimization of PET parameters

EJNMMI Physics. Mercy I. Akerele 1, Palak Wadhwa 1,2, Jesus Silva-Rodriguez 3, William Hallett 2 and Charalampos Tsoumpas 1,2*

2007 IEEE Nuclear Science Symposium Conference Record M26-296

The Design and Implementation of COSEM, an Iterative Algorithm for Fully 3-D Listmode Data

Scatter Correction in 3D PET

636 IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 24, NO. 5, MAY M. E. Kamasak*, C. A. Bouman, E. D. Morris, and K. Sauer

Non-Stationary CT Image Noise Spectrum Analysis

SINGLE-PHOTON emission computed tomography

Iterative and analytical reconstruction algorithms for varying-focal-length cone-beam

The Emory Reconstruction Toolbox Version 1.0

Fast Projectors for Iterative 3D PET Reconstruction

(RMSE). Reconstructions showed that modeling the incremental blur improved the resolution of the attenuation map and quantitative accuracy.

SUV Analysis of F-18 FDG PET Imaging in the Vicinity of the Bladder. Colleen Marie Allen. Graduate Program in Medical Physics Duke University

ATTENUATION CORRECTION IN SPECT DURING IMAGE RECONSTRUCTION USING INVERSE MONTE CARLO METHOD A SIMULATION STUDY *

Continuous Bed Motion Vs. Step-and-Shoot Acquisition on Clinical Whole-Body Dynamic and Parametric PET Imaging

Resolution and Noise Properties of MAP Reconstruction for Fully 3-D PET

The use of the modulation transfer function for comparison and image quality assessment of commercially available hybrid PET-CT scanners

STATISTICAL positron emission tomography (PET) image

3-D Monte Carlo-based Scatter Compensation in Quantitative I-131 SPECT Reconstruction

PET Image Reconstruction Cluster at Turku PET Centre

A Comparison of the Uniformity Requirements for SPECT Image Reconstruction Using FBP and OSEM Techniques

Impact of X-ray Scatter When Using CT-based Attenuation Correction in PET: A Monte Carlo Investigation

Advanced Image Reconstruction Methods for Photoacoustic Tomography

White Paper. EQ PET: Achieving NEMAreferenced. Technologies. Matthew Kelly, PhD, Siemens Healthcare

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

Quantitative Attenuation Correction for PET/CT Using Iterative Reconstruction of Low-Dose Dual-Energy CT

Time-of-Flight Technology

An object-oriented library for 3D PET reconstruction using parallel computing

MAXIMUM a posteriori (MAP) or penalized ML image

Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET

Automatic Thresholding for Frame-Repositioning Using External Tracking in PET Brain Imaging

Simultaneous measurement of noise and spatial resolution in PET phantom images

CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION

IN single photo emission computed tomography (SPECT)

Motion Correction in PET Image. Reconstruction

Correction of Head Movement on PET Studies: Comparison of Methods

Positron Emission Tomography Partial Volume Correction: Estimation and Algorithms

Introduction to Neuroimaging Janaina Mourao-Miranda

Monte-Carlo-Based Scatter Correction for Quantitative SPECT Reconstruction

Principles of PET Imaging. Positron Emission Tomography (PET) Fundamental Principles WHAT IS PET?

A publicly accessible Monte Carlo database for validation purposes in emission tomography

ADVANCES IN FLUKA PET TOOLS

Transcription:

PET Quantification using STIR STIR User s Meeting Charalampos Tsoumpas, PhD King s College London Hammersmith Imanet 1

PET Quantification Image elements should correspond to concentration of the injected radiotracer What corrections are necessary for it: Attenuation Scatter Motion Randoms Normalization Dead Time 2

Overview of the talk PET Quantification using STIR: 3D Scatter Correction Parametric Reconstruction Theory How to use Examples Limitations & Future Work 3

3D Scatter Correction Single Scatter Simulation - SSS The scatter probabilities are estimated by Klein-Nishina formula for each possible scatter point in the transmission image. Compensation for multiple and out of the FoV scattering Each plane of the scatter estimation is scaled by an appropriate factor Watson CC et al. A single-scatter simulation technique for scatter correction in 3D PET 4 Fully 3D Image Recon in Radiology & Nucl Med. 1996

Implementation in STIR Scatter Buildblock classes and relative files ScatterEstimationByBin sample_scatter_points scatter_estimate_for_one_scatte r_point integral_scattpoint_det cached_factors scatter_estimate_for_all_scatte r_points estimate_scatter upsample_and_fit_scatter_estima te create_tail_mask_from_acfs scale_single_scatter 5

Scatter Correction in 4 steps STEP 1 http://www.medical.siemens.com STEP 2 STEP 3 Watson CC New, Faster, Image-Based Scatter Correction for 3D PET IEEE Trans. Nucl. Sci. 47 (4) 1587-1594, 2000 6

STIR How To: Scatter Correct STEP 1: estimate_scatter scatter.par attenuation_threshold :=.01 random :=0 use_cache :=1 energy_resolution :=.22 lower_energy_threshold :=350 upper_energy_threshold :=650 activity_image_filename := ${ACTIVITY_IMAGE} density_image_filename := ${DENSITY_IMAGE} density_image_for_scatter_points_filename:=${low_res_density_image} template_proj_data_filename := ${TEMPLATE} output_filename_prefix :=${OUTPUT_PREFIX} End Scatter Estimation Parameters:= 7

STIR How To: Scatter Correct STEP 2: create_tail_mask_from_acfs --ACF-filename <projdata> --ACF-threshold <number (1.01)> --output-filename <projdata> --safety-margin <0> STEP 3: scale_single_scatter --min-scale-factor <number> --max-scale-factor <number> --remove-interleaving <1 0> --half-filter-width <number> --output-filename <filename> --data-to-fit <filename> --data-to-scale <filename> --weights <filename> STEP 4: Remove Scatter Estimate and repeat steps (1) and (3). Then, average the two scatter estimates. 8

Not corrected Phantom Results Corrected with SSS SimSET total scatter corrected 9

Implementation in STIR Current Limitations - Potential Optimizations: Three separate executables: merge all in one Upsampling for oblique sinograms is handled in a simple way: (pseudo)-inverse SSRB Potential Extensions ToF scatter correction Scatter estimation for List Mode data 10

Relevant Literature Tsoumpas C et al. Evaluation of the Single Scatter Simulation Algorithm Implemented in the STIR Library 2004 IEEE NSS-MIC, Rome. Aguiar P et al. Assessment of scattered photons on the quantification of small animal PET studies EANM, Athens, Greece, 2006. Dikaios N Scatter correction in 3D PET, MSc Thesis, Patras, Greece, 2006. Polycarpou I Evaluation of Scatter Correction Approaches in PET, MSc Thesis, King s College London, 2009. 11

Overview PET Quantification using STIR: 3D Scatter Correction Parametric Reconstruction Theory How to use Examples Limitations & Future Work 12

Quantitative dynamic studies 1 Dynamic Acquisition 2 Dynamic Reconstruction Input function 3 Parametric Image Kinetic Model 13

Parametric Reconstruction 1 Dynamic Acquisition Input function 2 Parametric Image Kinetic Model 14

Why Direct Reconstruction? - Image Reconstruction: FBP does not offer high resolution and quality parametric images, thus OSEM would be preferable. However, the statistical properties of the reconstructed images are not well approximated with normal distribution for OSEM (Foundations of Image Science, Barrett & Myers). - Kinetic Modelling: Assume Normal Distribution of emission images within repeated measurements. 15

Parametric Reconstruction An iterative algorithm based on OSEM that integrates the kinetic model in reconstruction (n K +1) (n ) 1 vk = K vk P bvf M kf b, f b, f P bvf k, v Y bf (n P b v f (K ) v k M k f ) + S bf + R bf M kf K: Kinetic Parameter M: Linear Kinetic Model Matrix S, R: Scatter and Random Sinograms P: System Matrix (including scanner geometry, attenuation, normalisation etc.) Y: Projection Data b, f, v, k: notations for sinogram, bins, time frames, voxels, kinetic parameter C. Tsoumpas, F.E. Turkheimer, K. Thielemans, "Study of direct and indirect parametric estimation 16 methods of linear models in dynamic positron emission tomography." Med Phys, 2008.

Implementation in STIR Modelling Buildblock classes and relative classes ParametricDiscretisedDensity KineticModel KineticParameters PatlakPlot ModelMatrix PlasmaSample/PlasmaData PoissonLogLikelihoodWithLinea rkineticmodelanddynamicprojec tiondata DynamicProjData DynamicDiscretisedDensity POSMAPOSL/POSSPS 17

STIR How To: Modelling Indirect Patlak Plot Example for Reference Tissue Patlak Plot Parameters:= time frame definition filename:=time.fdef starting frame := 23 calibration factor := 1 scale factor := 1 blood data filename := ref.roi ; In seconds Time Shift := 0 In total counts := 0 In correct scale := 1 end Patlak Plot Parameters:= Example for Plasma Input Function Patlak Plot Parameters:= time frame definition filename:=time.fdef starting frame := 23 calibration factor := 1942 scale factor := 1 blood data filename := plasma.tac ; In seconds Time Shift := 15 In total counts := 0 In correct scale := 1 end Patlak Plot Parameters:= Direct Reconstruction (POSMAPOSL or POSSPS) objective function type:=poissonloglikelihoodwithlinearkineticmodelanddynamicprojectiondata 18

Comparison of converged images of a single realization Two transaxial planes of the phantom images for one noise realization for the FDG uptake reconstructed with the different methods. Inverse grey scale was used ranging from 0 to the maximum of the original parametric planes. (Note that the last 96 POSEM iterations were performed with PMLEM) Tsoumpas C, PhD Thesis, Imperial College London, 2008 19

Example of an FDOPA study Comparison of parametric maps for a patient and a healthy volunteer on a large axial FoV and high sensitivity PET scanner. Angelis GI, MRes Thesis, Imperial College London, 2008 20

Quantitative Comparison Voxel-wise scatter plots comparing the quantitative values in the left and right striatum for a normal (left side) and an abnormal (right side) subject. 21

Need for Speed The mean ROI values (left) and standard deviation (right) for the tracer uptake on the left striatum are presented for a psychotic (up) and a normal (down) study. Three different descending subsets schemes are presented. G. Angelis, et al. WMIC, Nice, France, 2008. 22

Implementation in STIR Current Limitation: Compilation only by defining the NUM_PARAMS as preprocessor variable Possible Optimization: POSMAPOSL could use less fwd-projection steps Much faster convergence using alternates steps direct reconstruction (Wang and Qi, 2009 TMI) Potential Extensions Straight integration of other algorithms Additional temporal basis (e.g. Spectral Analysis, B- Splines) List-Mode based direct reconstruction 23

PET Quantification What next? Motion Correction Randoms Normalization Dead Time However, details from the scanner manufacturers are not easily accessible. 24

Acknowledgments Kris Thielemans (Supervisor) Federico Turkheimer (Academic supervisor) Pablo Aguiar (SSS Evaluation) Georgios Angelis (Direct Recon Schemes Optimization) Nikolaos Dikaios (Extending/Testing SSS) Ravindra Manjeswar (SimSET Data) Irene Polycarpou (Scatter Correction Evaluation) 25